The inspection was conducted on September 30, 2024, using X-ray fluorescence (XRF) analyzers to identify paint containing lead concentrations at or above 1.0 mg/cm² as defined by EPA and Puerto Rico's Department of Natural and Environmental Resources (DRNA). Three state-certified risk assessors performed approximately 603 samples across multiple buildings and site areas. The report identified lead-based paint in selective components and surfaces, with specific findings including: bases on concrete (8 Ft²), floor lines on concrete (250 linear feet total), ceramic sinks (2 units), wall surfaces on concrete (660 Ft²), exterior metal columns (6 units at 10 Ft² each), metal corner guards (2 units at 10 Ft² each), metal fence poles (2 units), metal cannons (2 units), metal bollards (1 unit), wooden and metal light poles (3 wooden units up to 5 feet and 1 metal unit). The report specifies that abatement of contaminated surfaces must be performed by DRNA-certified abatement firms before any demolition, with abatement methods warranted to last at least 20 years. According to DRNA regulations, the report maintains validity for five years. The inspection followed HUD Guidelines methodology and included photographic documentation, detailed XRF sampling data tables, certifications of inspectors, XRF performance characteristic sheets, and location maps of positive materials across the various structures and site areas evaluated.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Lead-Based Paint Inspection Report
Project:
Various Buildings Areas- DPW at Camp Santiago, Salinas, Puerto Rico
Client:
PRNG
ZEM-24286
November 2024
Prepared By:
Zimmetry Environmental Management, Corp.
www.zimmetry.com info@zimmetry.com
Lead Based Paint Inspection Project No. ZEM-24286
Table Of Content
Section 1: Executive Summary
1.1 Introduction
1.2 Summary of Property Evaluation
1.3 Property Locations of Building Components with Lead-Based Paint
Table 1-1: Summary of Components Containing Lead
Area
Section 2: Lead-Based Paint Inspection Report
2.1 Overview of the Evaluation
2.2 Sampling Procedure
2.3 Results Presentation
2.3.1 Specific Findings
2.3.2 Homogeneous Areas with Special Considerations
2.3.3 Inaccessible Areas Presumed to be Lead-Based Painted
2.4 Lead Regulatory Levels
Table 2-1: Lead Regulatory Levels
2.5 Conditions and Limitations—Disclaimer
2.6 Abatement Conditions
2.7 Recommendations
2.8 Environmental Assessment Report Certification
Section 3: Appendices
List of Appendices Appendix A: Certifications, Licenses, and Accreditations Appendix B: XRF Sampling Data Appendix C: XRF’s Performance Characteristics Sheet Appendix D: Photographic Record Appendix E: Location of Positive Materials
Section 1: Executive Summary
1.1 Introduction
A Lead-Based Paint inspection was conducted on September 30, 2024, at Various Buildings Areas- DPW at Camp Santiago, Salinas, Puerto Rico. The lead-based paint inspection was performed to identify paint that contains lead above allowable levels and to assist with compliance with local, state, and federal regulations.
1.2 Summary of Property Evaluation
The inspection consisted of the evaluation of the interior and exterior areas of the project mentioned above. The inspection determined that lead-based paint was present in selective components and surfaces throughout the project on the inspection date. Table 1-1 identifies the components positive for lead. Table 2-1 identifies lead-based paint as defined by the U.S.
Environmental Protection Agency (EPA) and the Department of Natural and Environmental Resources (DRNA) of Puerto Rico. For specific locations and additional details on the lead location- reference Sections 2 and 3.
1.3 Property Locations of Building Components with Lead-Based Paint
Table 1-1 summarizes the site components and surfaces coated with lead-based paint. Additional details identifying positive lead-based paint findings within specific areas and on surfaces are provided in Section 2: Lead-Based Paint Inspection Report. The “substrate” is the building component material directly beneath the painted surface. Photographic documentation is for reference purposes and doesn't necessarily include all the surfaces with lead-based paint and/or components containing lead. The quantification of positive materials presented in this table is only an estimate. If an abatement of the materials will be conducted, the Contractors shall estimate the amount of materials to be abated.
If homogeneous materials not accounted for are identified in areas not described in this report or inaccessible areas described in Section 2.3.3, they shall be managed as containing lead. If suspected components that could contain lead are encountered underneath currently installed tiles or other construction material, they shall be managed as containing lead until the appropriate test is performed. Refer to Appendix E: Location of Positive Materials for specific locations.
Note:
1. The quantification of positive materials presented in this table is only an estimate. If an abatement of the materials will be conducted, the Contractors shall estimate the amount of materials to be abated.
Table 1-1: Summary of Components Containing Lead
Structure Area Component Color Substrate Approx. Amount
1 1-1 Base Yellow Concrete 8 Ft2
057/ 058 1-1 Floor Lines Yellow Concrete 225 Ln Ft
1-3 & 1-7 Sink White Ceramic 2 Units
1-1 Wall Surfaces (B, C and D) Gray Concrete
660 Ft2
1-4 Wall Surfaces (C and D) Gray Concrete
1-2 & 1-3 Wall Surfaces (B and C) Gray/ Cream Concrete
1-7 Wall Surface
(A and D) Cream Concrete
1-3 Floor Lines Yellow Concrete 25 Ln Ft
Exterior Area A
Columns Cream Metal 6 Units (10 Ft2 Each)
Corner Guards Cream Metal 2 Units (10 Ft2 Each)
Site
Fence Poles Yellow Metal 2 Units
Cannon Red/Black Metal 2 Units
Light Poles Yellow/ Gray Wood/Metal 3 Wooden Units (Up to 5 Ft) & 1 Metal Unit
Bollard Yellow Metal 1 Unit
Section 2: Lead-Based Paint Inspection Report
2.1 Overview of the Evaluation
This lead-based paint inspection is an investigation to identify all lead-based paint on a surface-by-surface basis. A lead-based paint inspection conforming to HUD guidelines was performed at the project mentioned above.
An average of 603 samples were taken at identified surfaces of the evaluated areas using an X-ray fluorescence (XRF) analyzer. The evaluation found that lead-based paint was present in selective components and surfaces through the project on the assessment date (See Table 1-1).
Some of the remaining XRF test locations exhibited lead-in-paint levels below the level that EPA identifies as lead-based paint, namely 1.0 mg/cm2. Such surfaces could create dust-lead or soil-lead hazards if the paint is turned into dust by abrasion, scraping, or sanding. Should these or any lead-containing components or surfaces be disturbed in any manner that generates dust, care should be taken to limit its spread.
Testing was performed by Dilia Rosado, state-certified risk assessor LBPRA-19924-238, by Alicia Garcia, state-certified risk assessor LBPRA-07124-074, and by Harry Peña, state-certified risk assessor LBPRA-19924-239, using the Niton XLp-300A XRF, SN-101222, the Niton XLp- 300A XRF, SN-18574 and the Niton XLp-300A XRF, SN-25492, respectively. The credentials are provided in Section 3, Appendix A: Certifications, Licenses, and Accreditations. The XRF analyzer is designed to measure the lead content of surface coatings on various building surfaces, substrates, and components. The measurement is rapid and nondestructive and, according to the manufacturer, can detect lead concentrations within numerous layers of various surface coatings.
Please refer to the XRF Testing Results Section 3, Appendix B: XRF Sampling Data for each inspected area's detailed analytical testing results. The reports provide complete testing data.
2.2 Sampling Procedure
The Lead-Based Paint Sampling Procedure was designed to evaluate and document all the data obtained from the inspection in a sequential method that provided confidence at the moment of the presentation of the results.
The survey followed the methodology established in the HUD Guidelines for the Evaluation and Control of Lead-Based Paint in Housing (2012 revision) and the Department of Natural and Environmental Resources (DRNA) of Puerto Rico Regulation 9098: Regulation for Proper Management of Lead-Based Paint Activities. The surface-by-surface evaluation was performed as follows:
• If the lead concentration measured by the XRF Spectrum Analyzer is less than 1.0 mg/cm2, it is considered negative.
• If the lead concentration measured by the XRF Spectrum Analyzer is equal to or greater than
1.0 mg/cm2, it is considered positive.
A name was assigned to each functional space of the project based on the use of that space. A code letter or number was assigned if no name could be assigned.
Each wall surface was named with letters beginning with wall A, the wall facing the main entrance direction. The wall on your left will be wall B, the wall in front wall C, and the wall on your right will be wall D.
2.3 Results Presentation
This section describes the project components and surfaces coated with lead-based paint (LBP), which were observed in the inspection. Please note that the recommendations given are the minimum required action, which should be taken based on our professional judgment.
According to the DRNA lead regulations, before demolishing a structure containing lead-based paint, the contaminated surfaces or substrates must be abated or removed. The abatement firm must be certified as an abatement firm by the DRNA.
2.3.1 Specific Findings
The following LBP was found to contain more than 1.0 mg/cm2 for what the Department of Natural and Environmental Resources (DRNA) of Puerto Rico identifies as lead-based paint or materials containing lead:
• Base
• Bollard
• Cannon
• Fence Poles
• Floor Lines
• Light Poles
• Column • Sink
• Corner Guards • Wall Surfaces
2.3.2 Homogeneous Areas with Special Considerations
NONE
2.3.3 Inaccessible Areas Presumed to be Lead-Based Painted
NONE
2.4 Lead Regulatory Levels
The lead regulatory levels provided below are those used when preparing this lead-based paint evaluation or when evaluating data collected. The EPA regulatory levels are the same as the state regulatory levels provided in the following table.
Table 2-1: Lead Regulatory Levels
EPA/DRNA Levels
Lead-Based Paint
1.0 mg/cm2 or 0.5% by weight (or 5,000 ppm)
2.5 Conditions and Limitations—Disclaimer
Zimmetry Environmental Management Corp. has performed this lead-based paint inspection thoroughly and professionally, consistent with commonly accepted industry standards. The Preparer cannot guarantee and does not warrant that this evaluation has identified all adverse environmental factors and/or conditions affecting this project on the evaluation date.
The results reported, and conclusions reached by the Preparer are solely for the Owner's benefit.
The results and opinions in this report, based solely on the conditions found at the project on the evaluation date, are valid only on that date. The Preparer assumes no obligation to advise the client of any changes in any actual or potential lead-based paint hazards at this project beyond the date of the evaluation.
The lead inspection was performed to ready accessible components and surfaces. If suspected components that could contain lead are encountered underneath currently installed tiles or other construction material, they shall be managed as containing lead until the appropriate test is performed. According to the DRNA in the “Regulation for the Proper Management of Lead-Based Paint Activities” Rule 139 (Section E, Part 17), all lead-based paint reports have a validity period of five (5) years.
2.6 Abatement Conditions
As defined by HUD and the Department of Natural and Environmental Resources (DRNA) of Puerto Rico, abatement means any set of measures designed to permanently eliminate lead-based paint and/or lead-based paint hazards. The people providing these services must be trained under the DRNA licensing/certification requirements. The product manufacturer and/or contractor must warrant abatement methods to last at least 20 years, or these methods must have a design life of at least 20 years.
• onsite or offsite removal of lead-based paint from substrates and components
• replacement of components or fixtures painted with lead-based paint
• permanent enclosure of lead-based paint with construction materials mechanically fastened to the substrate
• encapsulation of lead-based paint with specially designed encapsulant products
• removal or permanent covering (concrete or asphalt) of soil-lead-based paint hazards
If enclosure or encapsulation is conducted as an abatement method, the lead-based paint remains on the property, so ongoing lead-based paint maintenance is required.
2.7 Recommendations
According to the DRNA lead regulations, before demolishing a structure containing lead-based paint, the contaminated surfaces or substrates must be abated or removed. The waste generated has to be characterized to determine if the waste generated is hazardous or non-hazardous waste.
The abatement firm must be certified as an abatement firm by the DRNA. Workers conducting abatement must be trained and certified as abatement workers by a training provider accredited by the DRNA.
2.8 Environmental Assessment Report Certification
Zimmetry Environmental Management Corp. has performed this lead-based paint inspection thoroughly and professionally, consistent with commonly accepted industry standards. The inspection was conducted on September 30, 2024, by Dilia Rosado, state-certified risk assessor LBPRA-19924-238, by Alicia Garcia, state-certified risk assessor LBPRA-07124-07, and by Harry Peña, state-certified risk assessor LBPRA-19924-239, all qualified by experience, education, and training in the recognition of lead-based paint and approved sampling techniques using the Niton XLp-300A XRF, SN-101222, the Niton XLp-300A XRF, SN-18574 and the Niton XLp-300A XRF, SN-25492, respectively.
Dilia Rosado, MEM Environmental Risk Assessor
Alicia García Justiniano, MSc
Harry Peña, MSEM
Section 3: Appendices Appendix A: Certifications, Licenses, and Accreditations Appendix B: XRF Sampling Data Appendix C: XRF’s Performance Characteristics Sheet Appendix D: Photographic Record Appendix E: Location of Positive Materials
APPENDIX A
Certifications, Licenses and
Accreditations
APPENDIX B
XRF Sampling Data
PROJECT:
DATE: 9/30/2024
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
1 Calibration 1.00
2 Calibration 1.00
3 Calibration 1.00
4 Area 1-1 Door Brown Metal 0.00 Negative
5 Area 1-1 Door Frame Brown Metal 0.00 Negative
6 Area 1-1 Floor Tile Gray Ceramic 0.02 Negative
7 Area 1-1 Baseboard Gray Ceramic 0.01 Negative
8 Area 1-1 Wall A Cream Concrete 0.01 Negative
9 Area 1-1 Wall A Cream Concrete 0.00 Negative
10 Area 1-1 Wall C Cream Concrete 0.01 Negative
11 Area 1-1 Wall D Cream Concrete 0.00 Negative
12 Area 1-1 Wall B Cream Wood 0.00 Negative
13 Area 1-1 Window Shutter White Metal 0.00 Negative
14 Area 1-2 Door Brown Wood 0.00 Negative
15 Area 1-2 Door Frame Brown Wood 0.00 Negative
16 Area 1-2 Floor Tile Gray Ceramic 0.03 Negative
17 Area 1-2 Floor Tile Gray Ceramic 0.01 Negative
18 Area 1-2 Baseboard Gray Ceramic 0.02 Negative
19 Area 1-2 Wall A Cream Concrete 0.00 Negative
20 Area 1-2 Wall B Cream Drywall 0.00 Negative
21 Area 1-2 Wall C Cream Concrete 0.00 Negative
22 Area 1-2 Wall D Brown Wood 0.00 Negative
23 Area 1-2 Window Shutter White Metal 0.02 Negative
24 Area 1-2 Window Shutter White Metal 0.00 Negative
25 Area 1-2 Door Brown Metal 0.00 Negative
26 Area 1-2 Door Frame Brown Metal 0.00 Negative
27 Area 1-3 Door Brown Metal 0.00 Negative
28 Area 1-3 Door Frame Brown Metal 0.00 Negative
29 Area 1-3 Wall A Cream Concrete 0.02 Negative
30 Area 1-3 Wall B Cream Concrete 0.00 Negative
31 Area 1-3 Wall C Cream Concrete 0.00 Negative
32 Exterior Area Wall A Cream Concrete 0.00 Negative
33 Exterior Area Wall B Cream Concrete 0.00 Negative
34 Exterior Area Wall C Cream Concrete 0.02 Negative
35 Exterior Area Wall D Cream Concrete 0.00 Negative
36 Exterior Area Wall A Cream Concrete 0.03 Negative
37 Exterior Area Wall B Cream Concrete 0.00 Negative
38 Exterior Area Wall C Cream Concrete 0.03 Negative
39 Exterior Area Wall D Cream Concrete 0.00 Negative
40 Exterior Area Wall A Cream Concrete 0.00 Negative
41 Exterior Area Wall B Cream Concrete 0.01 Negative
42 Exterior Area Wall C Cream Concrete 0.00 Negative
43 Exterior Area Wall D Cream Concrete 0.00 Negative
44 Exterior Area Wall A Cream Concrete 0.00 Negative
45 Exterior Area Wall B Cream Concrete 0.00 Negative
46 Exterior Area Wall C Cream Concrete 0.02 Negative
47 Exterior Area Wall D Cream Concrete 0.00 Negative
48 Exterior Area Wall A Cream Concrete 0.01 Negative
49 Exterior Area Wall B Cream Concrete 0.00 Negative
50 Exterior Area Wall C Cream Concrete 0.00 Negative
51 Exterior Area Wall D Cream Concrete 0.00 Negative
52 Exterior Area Wall A Cream Concrete 0.03 Negative
53 Exterior Area Wall B Cream Concrete 0.00 Negative
54 Exterior Area Wall C Cream Concrete 0.00 Negative
55 Exterior Area Wall D Cream Concrete 0.00 Negative
56 Exterior Area Wall A Cream Concrete 0.00 Negative
57 Exterior Area Wall B Cream Concrete 0.01 Negative
58 Exterior Area Wall C Cream Concrete 0.00 Negative
59 Exterior Area Wall D Cream Concrete 0.02 Negative
60 Exterior Area Wall A Cream Concrete 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Bldg. 56 LBP Inspector: Alicia García
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
61 Exterior Area Wall B Cream Concrete 0.02 Negative
62 Exterior Area Wall C Cream Concrete 0.00 Negative
63 Exterior Area Wall D Cream Concrete 0.02 Negative
64 Exterior Area Soffit Cream Wood 0.00 Negative
65 Exterior Area Soffit Cream Metal 0.00 Negative
66 Exterior Area Wall B Cream Metal 0.00 Negative
67 Exterior Area Wall D Cream Metal 0.00 Negative
68 Exterior Area Soffit Cream Wood 0.01 Negative
69 Exterior Area Soffit Cream Metal 0.00 Negative
LBP Inspector: Alicia GarcíaBldg. 56
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
70 Area 1-1 Wall A Cream Concrete 0.00 Negative
71 Area 1-1 Wall B Cream Concrete 0.00 Negative
72 Area 1-1 Wall C Cream Concrete 0.02 Negative
73 Area 1-1 Wall D Cream Concrete 0.00 Negative
74 Area 1-1 Wall A Cream Concrete 0.02 Negative
75 Area 1-1 Wall B Cream Concrete 0.00 Negative
76 Area 1-1 Wall C Cream Concrete 0.00 Negative
77 Area 1-1 Wall D Cream Concrete 0.00 Negative
78 Area 1-1 Floor Marking White Concrete 0.00 Negative
79 Area 1-1 Floor Line Yellow Concrete 4.50 Positive
80 Area 1-1 Floor Line Yellow Concrete 10.20 Positive
81 Area 1-1 Window Shutter White Metal 0.00 Negative
82 Area 1-1 Window Shutter White Metal 0.00 Negative
83 Area 1-1 Door Green Wood 0.00 Negative
84 Area 1-1 Door Frame Green Wood 0.00 Negative
85 Area 1-1 Beam Red Metal 0.00 Negative
86 Area 1-2 Wall A White Wood 0.01 Negative
87 Area 1-2 Wall B White Wood 0.00 Negative
88 Area 1-2 Wall B White Concrete 0.00 Negative
89 Area 1-2 Wall C White Wood 0.00 Negative
90 Area 1-2 Wall D Cream Concrete 0.02 Negative
91 Area 1-2 Ceiling Cream Wood 0.00 Negative
92 Area 1-2 Floor Gray Concrete 0.00 Negative
93 Area 1-3 Wall A White Wood 0.00 Negative
94 Area 1-3 Wall B Gray Concrete 0.02 Negative
95 Area 1-3 Wall C Gray Concrete 0.00 Negative
96 Area 1-3 Wall D Gray Concrete 0.00 Negative
97 Area 1-3 Rolling Door Gray Metal 0.00 Negative
98 Area 1-3 Rolling Door Frame Gray Metal 0.00 Negative
99 Area 1-3 Window Shutter White Metal 0.00 Negative
100 Area 1-3 Door White Wood 0.00 Negative
101 Area 1-3 Door Frame White Wood 0.00 Negative
102 Area 1-3 Sink White Ceramic 30.50 Positive
103 Area 1-4 Under sink Cabinet Wall A Cream Concrete 0.00 Negative
104 Area 1-4 Under sink Cabinet Wall C Cream Concrete 0.00 Negative
105 Area 1-4 Under sink Cabinet Wall D Cream Concrete 0.03 Negative
106 Area 1-4 Under sink Cabinet Ceiling Varnish Wood 0.00 Negative
107 Area 1-4 Under sink Cabinet Door White Wood 0.00 Negative
108 Area 1-4 Under sink Cabinet Door Frame Gray Wood 0.00 Negative
109 Area 1-5 Wall A White Concrete 0.00 Negative
110 Area 1-5 Wall B White Concrete 0.01 Negative
111 Area 1-5 Wall D White Concrete 0.00 Negative
112 Area 1-5 Wall C White Wood 0.00 Negative
113 Area 1-5 Door Green Wood 0.00 Negative
114 Area 1-5 Door Frame Green Wood 0.00 Negative
115 Area M-1 Wall B White Concrete 0.02 Negative
116 Area M-1 Wall D White Concrete 0.00 Negative
117 Area M-1 Floor Green Wood 0.00 Negative
118 Area M-1 Beam Red Metal 0.01 Negative
119 Area 1-6 Door Green Wood 0.00 Negative
120 Area 1-6 Door Frame Green Wood 0.00 Negative
121 Area 1-6 Floor Gray Concrete 0.00 Negative
122 Area 1-6 Wall A White Concrete 0.02 Negative
123 Area 1-6 Wall B White Concrete 0.00 Negative
124 Area 1-6 Wall D White Concrete 0.00 Negative
125 Area 1-7 Sink White Ceramic 27.20 Positive
126 Area 1-7 Floor Gray Concrete 0.00 Negative
127 Area 1-7 Wall A Cream Wood 0.00 Negative
128 Area 1-7 Column Gray Wood 0.00 Negative
129 Area 1-7 Wall B Cream Concrete 0.02 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Bldg. 057/ 058 LBP Inspector: Alicia Garcia
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
130 Area 1-7 Wall C Cream Wood 0.00 Negative
131 Area 1-7 Wall D Cream Wood 0.00 Negative
132 Area 1-7 Ceiling Cream Wood 0.01 Negative
133 Area 1-7 Baseboard Cream Wood 0.00 Negative
134 Area 1-7 Door White Wood 0.03 Negative
135 Area 1-7 Door Frame White Wood 0.00 Negative
136 Area 1-8 Door White Wood 0.00 Negative
137 Area 1-8 Door Frame White Wood 0.00 Negative
138 Area 1-8 Wall A Gray Concrete 0.02 Negative
139 Area 1-8 Wall B Gray Concrete 0.00 Negative
140 Area 1-8 Wall C Gray Concrete 0.01 Negative
141 Area 1-8 Rolling Door Gray Metal 0.00 Negative
142 Area 1-8 Rolling Door Frame Gray Metal 0.00 Negative
143 Area 1-8 Urinal White Ceramic 0.02 Negative
144 Area 1-8 Window Shutter White Metal 0.00 Negative
145 Area M-2 Floor Green Wood 0.00 Negative
146 Area M-2 Wall B White Concrete 0.00 Negative
147 Area M-2 Wall D White Concrete 0.01 Negative
148 Area M-2 Beam Red Metal 0.00 Negative
Bldg. 057/ 058
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
LBP Inspector: Alicia Garcia
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
149 Area 1-1 Rolling Door Gray Metal 0.00 Negative
150 Area 1-1 Rolling Door Frame Gray Metal 0.00 Negative
151 Area 1-1 Wall A Cream Concrete 0.00 Negative
152 Area 1-1 Wall B Gray Concrete 5.00 Positive
153 Area 1-1 Wall B Cream Metal 0.00 Negative
154 Area 1-1 Window Shutter White Metal 0.00 Negative
155 Area 1-1 Wall C Gray Concrete 3.20 Positive
156 Area 1-1 Wall C Cream Metal 0.00 Negative
157 Area 1-1 Wall D Gray Concrete 5.30 Positive
158 Area 1-1 Wall D Cream Metal 0.00 Negative
159 Area 1-1 Lavatory White Ceramic 0.02 Negative
160 Area 1-1 Door Green Metal 0.00 Negative
161 Area 1-1 Door Frame Green Metal 0.00 Negative
162 Area 1-1 Wall C White Wood 0.00 Negative
163 Area 1-2 Wall A Varnish Wood 0.00 Negative
164 Area 1-2 Wall B Cream Metal 0.00 Negative
165 Area 1-2 Wall B Gray Concrete 5.00 Positive
166 Area 1-2 Wall C Cream Concrete 5.20 Positive
167 Area 1-2 Wall C Cream Metal 0.00 Negative
168 Area 1-3 Wall B Gray Concrete 3.00 Positive
169 Area 1-3 Wall C Gray Concrete 3.60 Positive
170 Area 1-3 Wall C Cream Metal 0.00 Negative
171 Area 1-3 Window Shutter White Metal 0.00 Negative
172 Area 1-3 Floor Line Yellow Concrete 2.00 Positive
173 Area 1-3 Wall D Cream Wood 0.00 Negative
174 Area 1-4 Door Cream Wood 0.00 Negative
175 Area 1-4 Door Frame Cream Wood 0.00 Negative
176 Area 1-4 Wall A Cream Wood 0.00 Negative
177 Area 1-4 Wall B Cream Wood 0.00 Negative
178 Area 1-4 Wall C Gray Concrete 3.50 Positive
179 Area 1-4 Wall D Gray Concrete 5.00 Positive
180 Area 1-4 Window Shutter White Metal 0.00 Negative
181 Area 1-4 Wall D Cream Metal 0.00 Negative
182 Area 1-4 Wall C Cream Metal 0.00 Negative
183 Area 1-6 Bathroom Floor Tile Cream Ceramic 0.01 Negative
184 Area 1-6 Bathroom Wall Tile Cream Ceramic 0.02 Negative
185 Area 1-6 Bathroom Lavatory Yellow Ceramic 0.02 Negative
186 Area 1-6 Bathroom Urinal White Ceramic 0.03 Negative
187 Area 1-6 Bathroom Toilet White Ceramic 0.01 Negative
188 Area 1-6 Bathroom Window Shutter White Metal 0.00 Negative
189 Area 1-6 Bathroom Wall A Cream Concrete 0.02 Negative
190 Area 1-6 Bathroom Wall B Cream Concrete 0.00 Negative
191 Area 1-6 Bathroom Wall C Cream Concrete 0.00 Negative
192 Area 1-6 Bathroom Wall D Cream Concrete 0.00 Negative
193 Area 1-6 Bathroom Door White Metal 0.00 Negative
194 Area 1-6 Bathroom Door Frame White Metal 0.00 Negative
195 Area 1-6 Bathroom Ceiling Cream Concrete 0.02 Negative
196 Area 1-7 Door Green Metal 0.00 Negative
197 Area 1-7 Door Frame Green Metal 0.00 Negative
198 Area 1-7 Wall A Cream Metal 0.00 Negative
199 Area 1-7 Wall A Cream Concrete 1.40 Positive
200 Area 1-7 Wall B Cream Metal 0.00 Negative
201 Area 1-7 Wall C Varnish Wood 0.00 Negative
202 Area 1-7 Wall D Cream Concrete 1.00 Positive
203 Exterior Area Column Cream Metal 3.50 Positive
204 Exterior Area Wall A Cream Wood 0.00 Negative
205 Exterior Area Wall A Cream Concrete 0.00 Negative
206 Exterior Area Wall A Green Wood 0.00 Negative
207 Exterior Area Corner Guard Cream Metal 5.20 Positive
208 Exterior Area Beam Cream Metal 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Bldg. 050 LBP Inspector: Alicia Garcia
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
209 Exterior Area Beam Cream Metal 0.01 Negative
210 Exterior Area Wall B Cream Concrete 0.00 Negative
211 Exterior Area Wall B Cream Concrete 0.00 Negative
212 Exterior Area Wall B Cream Metal 0.03 Negative
213 Exterior Area Wall B Cream Metal 0.00 Negative
214 Exterior Area Wall C Cream Concrete 0.00 Negative
215 Exterior Area Wall D Cream Concrete 0.00 Negative
216 Exterior Area Wall C Cream Metal 0.03 Negative
217 Exterior Area Wall D Cream Metal 0.00 Negative
218 Exterior Area Wall C Cream Wood 0.00 Negative
219 Exterior Area Wall C Black Wood 0.00 Negative
220 Calibration 1.00
221 Calibration 1.00
222 Calibration 1.00
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Bldg. 050 LBP Inspector: Alicia Garcia
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
223 Calibration 1.00
224 Calibration 1.00
225 Calibration 1.00
226 Area 1-1 Wall A Cream Concrete 0.00 Negative
227 Area 1-1 Wall B Cream Concrete 0.03 Negative
228 Area 1-1 Wall C Cream Concrete 0.00 Negative
229 Area 1-1 Wall D Cream Concrete 0.02 Negative
230 Area 1-1 Baseboard Brown Wood 0.00 Negative
231 Area 1-1 Door Blue Metal 0.00 Negative
232 Area 1-1 Door Frame Blue Metal 0.00 Negative
233 Area 1-1 Window Casing Brown Metal 0.00 Negative
234 Area 1-1 Door Brown Metal 0.00 Negative
235 Area 1-1 Door Frame Brown Metal 0.00 Negative
236 Area 1-2 Wall A Cream Concrete 0.01 Negative
237 Area 1-2 Wall C Cream Concrete 0.00 Negative
238 Area 1-2 Baseboard Brown Wood 0.00 Negative
239 Area 1-3 Door Brown Wood 0.00 Negative
240 Area 1-3 Door Frame Brown Wood 0.00 Negative
241 Area 1-3 Wall A Cream Concrete 0.02 Negative
242 Area 1-3 Wall B Cream Concrete 0.00 Negative
243 Area 1-3 Wall C Cream Concrete 0.03 Negative
244 Area 1-3 Wall D Cream Concrete 0.00 Negative
245 Area 1-3 Baseboard Brown Wood 0.01 Negative
246 Area 1-4 Door Brown Wood 0.00 Negative
247 Area 1-4 Door Frame Brown Wood 0.00 Negative
248 Area 1-4 Wall Tile White Ceramic 0.01 Negative
249 Area 1-4 Floor Tile Cream Ceramic 0.01 Negative
250 Area 1-4 Wall A Brown Concrete 0.00 Negative
251 Area 1-4 Wall B Brown Concrete 0.00 Negative
252 Area 1-4 Wall C Brown Concrete 0.00 Negative
253 Area 1-4 Wall D Brown Concrete 0.03 Negative
254 Area 1-4 Window Shutter White Metal 0.00 Negative
255 Area 1-5 Door Brown Wood 0.00 Negative
256 Area 1-5 Door Frame Brown Wood 0.00 Negative
257 Area 1-5 Wall A Cream Wood 0.00 Negative
258 Area 1-5 Wall B Cream Concrete 0.00 Negative
259 Area 1-5 Wall C Cream Concrete 0.02 Negative
260 Area 1-5 Wall D Cream Concrete 0.01 Negative
261 Area 1-5 Window Shutter White Metal 0.00 Negative
262 Area 1-5 Baseboard Brown Wood 0.00 Negative
263 Area 1-6 Wall C Cream Drywall 0.00 Negative
264 Area 1-6 Wall A Cream Concrete 0.00 Negative
265 Area 1-6 Wall B Cream Concrete 0.02 Negative
266 Area 1-6 Wall D Cream Concrete 0.00 Negative
267 Area 1-6 Baseboard Brown Wood 0.03 Negative
268 Area 1-6 Door Brown Wood 0.00 Negative
269 Area 1-6 Door Frame Brown Wood 0.00 Negative
270 Area 1-6 Window Shutter White Metal 0.00 Negative
271 Area 1-6 Crown Molding Brown Wood 0.00 Negative
272 Area 1-7 Door Brown Wood 0.02 Negative
273 Area 1-7 Door Frame Brown Wood 0.00 Negative
274 Area 1-7 Wall A Cream Concrete 0.00 Negative
275 Area 1-7 Wall B Cream Concrete 0.00 Negative
276 Area 1-7 Wall C Cream Concrete 0.01 Negative
277 Area 1-7 Wall D Cream Concrete 0.01 Negative
278 Area 1-8 Floor Tile Gray Ceramic 0.02 Negative
279 Area 1-8 Baseboard Gray Ceramic 0.02 Negative
280 Area 1-8 Wall A Gray Concrete 0.00 Negative
281 Area 1-8 Wall B Gray Concrete 0.00 Negative
282 Area 1-8 Wall C Gray Concrete 0.03 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Bldg. #5 LBP Inspector: Dilia Rosado
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
283 Area 1-8 Wall D Gray Concrete 0.00 Negative
284 Area 1-8 Door Brown Wood 0.00 Negative
285 Area 1-8 Door Frame Brown Wood 0.00 Negative
286 Area 1-8 Door Brown Wood 0.02 Negative
287 Area 1-8 Door Frame Brown Wood 0.00 Negative
288 Area 1-9 Door Brown Wood 0.00 Negative
289 Area 1-9 Door Frame Brown Wood 0.01 Negative
290 Area 1-9 Wall Tile White Ceramic 0.01 Negative
291 Area 1-9 Floor Tile Gray Ceramic 0.01 Negative
292 Area 1-9 Toilet White Ceramic 0.02 Negative
293 Area 1-9 Lavatory White Ceramic 0.03 Negative
294 Area 1-9 Window Shutter White Metal 0.00 Negative
295 Area 1-9 Ceiling Brown Wood 0.00 Negative
296 Area 1-9 Window Shutter White Metal 0.00 Negative
297 Area 1-10 Wall Tile White Ceramic 0.01 Negative
298 Area 1-10 Floor Tile Gray Ceramic 0.02 Negative
299 Area 1-10 Door Brown Wood 0.00 Negative
300 Area 1-10 Door Frame Brown Wood 0.00 Negative
301 Area 1-10 Toilet White Ceramic 0.02 Negative
302 Area 1-10 Lavatory White Ceramic 0.03 Negative
303 Area 1-10 Ceiling Brown Wood 0.00 Negative
304 Calibration 1.00
305 Calibration 1.00
306 Calibration 1.00
307 Area 1-11 Door Brown Wood 0.00 Negative
308 Area 1-11 Door Frame Brown Wood 0.00 Negative
309 Area 1-11 Wall A Cream Concrete 0.00 Negative
310 Area 1-11 Wall B Cream Concrete 0.02 Negative
311 Area 1-11 Wall C Cream Concrete 0.00 Negative
312 Area 1-11 Wall D Cream Concrete 0.00 Negative
313 Area 1-11 Baseboard Brown Wood 0.00 Negative
314 Area 1-11 Window Shutter White Metal 0.00 Negative
315 Area 1-12 Door Brown Wood 0.00 Negative
316 Area 1-12 Door Frame Brown Wood 0.00 Negative
317 Area 1-12 Wall A Cream Concrete 0.03 Negative
318 Area 1-12 Wall B Cream Concrete 0.00 Negative
319 Area 1-12 Wall C Cream Concrete 0.01 Negative
320 Area 1-12 Wall D Cream Concrete 0.00 Negative
321 Area 1-12 Window Shutter White Metal 0.00 Negative
322 Area 1-12 Baseboard Brown Wood 0.00 Negative
323 Area 1-13 Wall A Cream Concrete 0.00 Negative
324 Area 1-13 Wall B Cream Concrete 0.02 Negative
325 Area 1-13 Wall C Cream Concrete 0.00 Negative
326 Area 1-13 Wall D Cream Concrete 0.00 Negative
327 Area 1-13 Window Casing Black Metal 0.00 Negative
328 Area 1-13 Door Black Metal 0.00 Negative
329 Area 1-13 Door Frame Black Metal 0.00 Negative
330 Area 1-13 Floor Tile Cream Ceramic 0.02 Negative
331 Area 1-13 Baseboard Cream Ceramic 0.01 Negative
332 Area 1-14 Door Brown Wood 0.00 Negative
333 Area 1-14 Door Frame Brown Wood 0.00 Negative
334 Area 1-14 Wall A Cream Concrete 0.00 Negative
335 Area 1-14 Wall B Cream Concrete 0.02 Negative
336 Area 1-14 Wall C Cream Concrete 0.00 Negative
337 Area 1-14 Wall D Cream Concrete 0.01 Negative
338 Area 1-14 Window Casing Brown Metal 0.00 Negative
339 Area 1-14 Window Shutter White Metal 0.00 Negative
340 Exterior Area Wall A Cream Concrete 0.00 Negative
341 Exterior Area Wall A Cream Concrete 0.02 Negative
342 Exterior Area Wall A Cream Concrete 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
343 Exterior Area Column Cream Metal 0.00 Negative
344 Exterior Area Column Cream Metal 0.00 Negative
345 Exterior Area Soffit Brown Wood 0.01 Negative
346 Exterior Area Soffit Brown Wood 0.00 Negative
347 Exterior Area Fascia Brown Wood 0.00 Negative
348 Exterior Area Fascia Brown Wood 0.00 Negative
349 Exterior Area Ceiling White Metal 0.00 Negative
350 Exterior Area Ceiling White Metal 0.02 Negative
351 Exterior Area Column Cream Metal 0.00 Negative
352 Exterior Area Column Cream Metal 0.00 Negative
353 Exterior Area Column Cream Metal 0.03 Negative
354 Exterior Area Wall B Cream Concrete 0.00 Negative
355 Exterior Area Wall B Cream Concrete 0.01 Negative
356 Exterior Area Siding Cream Metal 0.00 Negative
357 Exterior Area Fascia Cream Metal 0.00 Negative
358 Exterior Area Soffit Cream Metal 0.00 Negative
359 Exterior Area Wall C Cream Concrete 0.03 Negative
360 Exterior Area Wall C Cream Concrete 0.00 Negative
361 Exterior Area Soffit Brown Wood 0.00 Negative
362 Exterior Area Wall D Cream Concrete 0.00 Negative
363 Exterior Area Siding Cream Metal 0.00 Negative
364 Exterior Area Fascia White Metal 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
365 Area 1-1 Door Brown Wood 0.24 Negative
366 Area 1-1 Door Frame Brown Wood 0.24 Negative
367 Area 1-1 Wall A Cream Concrete 0.00 Negative
368 Area 1-1 Wall B Cream Concrete 0.00 Negative
369 Area 1-1 Wall C Cream Concrete 0.00 Negative
370 Area 1-1 Wall D Cream Concrete 0.02 Negative
371 Area 1-1 Beam White Metal 0.00 Negative
372 Area 1-1 Window Shutter White Metal 0.00 Negative
373 Area 1-1 Lavatory White Ceramic 0.01 Negative
374 Area 1-4 Door Brown Wood 0.02 Negative
375 Area 1-4 Door Frame Brown Wood 0.00 Negative
376 Area 1-4 Wall A Cream Concrete 0.00 Negative
377 Area 1-4 Wall B Cream Concrete 0.02 Negative
378 Area 1-4 Wall C Cream Concrete 0.01 Negative
379 Area 1-4 Wall D Cream Concrete 0.00 Negative
380 Area 1-4 Beam White Metal 0.00 Negative
381 Area 1-4 Shelve Brown Wood 0.00 Negative
382 Area 1-4 Cabinet White Metal 0.00 Negative
383 Area 1-2 Door Brown Metal 0.03 Negative
384 Area 1-2 Door Frame Brown Metal 0.00 Negative
385 Area 1-2 Wall A Gray Concrete 0.00 Negative
386 Area 1-2 Wall B Gray Concrete 0.01 Negative
387 Area 1-2 Wall C Gray Concrete 0.01 Negative
388 Area 1-2 Wall D Gray Concrete 0.00 Negative
389 Area 1-2 Window Shutter White Metal 0.00 Negative
390 Area 1-2 Beam White Metal 0.00 Negative
391 Area 1-3 Door Gray Wood 0.00 Negative
392 Area 1-3 Door Frame Gray Wood 0.02 Negative
393 Area 1-3 Wall A Gray Concrete 0.00 Negative
394 Area 1-3 Wall B Gray Concrete 0.00 Negative
395 Area 1-3 Wall C Gray Concrete 0.00 Negative
396 Area 1-3 Wall D Gray Concrete 0.02 Negative
397 Area 1-3 Beam White Metal 0.00 Negative
398 Area 1-3 Grille White Metal 0.00 Negative
399 Area 1-3 Urinal White Ceramic 0.03 Negative
400 Area 1-5 Door Brown Wood 0.00 Negative
401 Area 1-5 Door Frame Brown Wood 0.00 Negative
402 Area 1-5 Wall A Cream Concrete 0.00 Negative
403 Area 1-5 Wall B Cream Concrete 0.01 Negative
404 Area 1-5 Wall C Cream Concrete 0.02 Negative
405 Area 1-5 Wall D Cream Concrete 0.00 Negative
406 Area 1-5 Window Shutter White Metal 0.00 Negative
407 Area 1-5 Beam White Metal 0.00 Negative
408 Area 1-5 Shelve Brown Wood 0.00 Negative
409 Area 1-5 Cabinet Brown Wood 0.00 Negative
410 Area 1-5 Cabinet Yellow Metal 0.00 Negative
411 Area 1-6 Door Brown Wood 0.02 Negative
412 Area 1-6 Door Frame Brown Wood 0.01 Negative
413 Area 1-6 Wall A Cream Concrete 0.00 Negative
414 Area 1-6 Wall B Cream Concrete 0.01 Negative
415 Area 1-6 Wall C Cream Concrete 0.00 Negative
416 Area 1-6 Wall D Cream Concrete 0.00 Negative
417 Area 1-6 Beam White Metal 0.00 Negative
418 Area 1-6 Grille White Metal 0.00 Negative
419 Area 1-6 Lavatory White Ceramic 0.02 Negative
420 Area 1-7 Door Brown Wood 0.00 Negative
421 Area 1-7 Door Frame Brown Wood 0.00 Negative
422 Area 1-7 Wall A Cream Concrete 0.00 Negative
423 Area 1-7 Wall B Cream Concrete 0.01 Negative
424 Area 1-7 Wall C Cream Concrete 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Bldg. #038 LBP Inspector: Dilia Rosado
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
425 Area 1-7 Wall D Cream Concrete 0.00 Negative
426 Area 1-7 Grille White Metal 0.00 Negative
427 Area 1-7 Cabinet Brown Wood 0.00 Negative
428 Area 1-7 Grille White Metal 0.02 Negative
429 Area 1-7 Beam White Metal 0.00 Negative
430 Area 1-8 (Terraza) Wall B Cream Concrete 0.00 Negative
431 Area 1-8 (Terraza) Column Brown Metal 0.00 Negative
432 Area 1-8 (Terraza) Beam Brown Metal 0.02 Negative
433 Area 1-8 (Terraza) Beam Cream Metal 0.01 Negative
434 Area 1-8 (Terraza) Column Base Cream Metal 0.00 Negative
435 Exterior Area Wall C Cream Concrete 0.00 Negative
436 Exterior Area Wall C Cream Concrete 0.00 Negative
437 Exterior Area Wall C Cream Concrete 0.03 Negative
438 Exterior Area Column Cream Metal 0.00 Negative
439 Exterior Area Wall B Cream Concrete 0.02 Negative
440 Exterior Area Wall B Cream Concrete 0.00 Negative
441 Exterior Area Wall B Cream Concrete 0.01 Negative
442 Exterior Area Column Cream Metal 0.00 Negative
443 Exterior Area Wall A Cream Concrete 0.00 Negative
444 Exterior Area Wall C Cream Wood 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Bldg. #038 LBP Inspector: Dilia Rosado
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
445 Area 1-1 Wall A Cream Concrete 0.00 Negative
446 Area 1-1 Wall B Cream Concrete 0.02 Negative
447 Area 1-1 Wall C Cream Concrete 0.00 Negative
448 Area 1-1 Wall D Cream Concrete 0.00 Negative
449 Area 1-1 Window Shutter White Metal 0.00 Negative
450 Area 1-1 Window Grille White Metal 0.03 Negative
451 Area 1-1 Cabinet Yellow Metal 0.01 Negative
452 Area 1-1 Door Brown Metal 0.00 Negative
453 Area 1-1 Ceiling White Concrete 0.00 Negative
454 Exterior Area Wall A Cream Concrete 0.00 Negative
455 Exterior Area Wall B Cream Concrete 0.02 Negative
456 Exterior Area Wall C Cream Concrete 0.00 Negative
457 Exterior Area Wall D Cream Concrete 0.01 Negative
458 Exterior Area Soffit Cream Concrete 0.00 Negative
459 Exterior Area Fascia Brown Concrete 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Bldg. #037 A LBP Inspector: Dilia Rosado
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
460 Area 1-1 Wall A White Metal 0.00 Negative
461 Area 1-1 Wall B White Metal 0.03 Negative
462 Area 1-1 Wall C White Metal 0.00 Negative
463 Area 1-1 Wall D White Metal 0.02 Negative
464 Area 1-1 Door White Metal 0.00 Negative
465 Area 1-1 Door Frame White Metal 0.00 Negative
466 Area 1-1 Ceiling White Metal 0.00 Negative
467 Exterior Area Wall A White Metal 0.00 Negative
468 Exterior Area Wall B White Metal 0.01 Negative
469 Exterior Area Wall C White Metal 0.00 Negative
470 Exterior Area Wall D White Metal 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Structure #2 LBP Inspector: Dilia Rosado
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
471 Area 1-1 Door Green Wood 0.00 Negative
472 Area 1-1 Door Frame Green Wood 0.03 Negative
473 Area 1-1 Siding White Metal 0.00 Negative
474 Exterior Area Wall A White Metal 0.00 Negative
475 Exterior Area Wall B White Metal 0.01 Negative
476 Exterior Area Wall C White Metal 0.00 Negative
477 Exterior Area Wall D White Metal 0.00 Negative
478 Exterior Area Beam Cream Metal 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Structure #3 LBP Inspector: Dilia Rosado
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
479 Area 1-1 Wall A White Concrete 0.00 Negative
480 Area 1-2 Wall B White Concrete 0.00 Negative
481 Area 1-3 Wall C White Concrete 0.02 Negative
482 Area 1-4 Wall D White Concrete 0.00 Negative
483 Area 1-5 Gate White Metal 0.00 Negative
484 Area 1-6 Gate White Metal 0.03 Negative
485 Exterior Area Wall A White Concrete 0.00 Negative
486 Exterior Area Wall B White Concrete 0.00 Negative
487 Exterior Area Wall C White Concrete 0.01 Negative
488 Exterior Area Wall D White Concrete 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Structure #4 LBP Inspector: Dilia Rosado
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
489 Area 1-1 Column Green Metal 0.02 Negative
490 Area 1-1 Column Green Metal 0.00 Negative
491 Area 1-1 Beam Green Metal 0.00 Negative
492 Area 1-1 Base Concrete Metal 14.70 Positive
493 Area 1-1 Siding White Metal 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Structure #1 LBP Inspector: Dilia Rosado
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
494 Area 1-1 Door Brown Wood 0.00 Negative
495 Area 1-1 Door Frame Brown Wood 0.00 Negative
496 Area 1-1 Wall A Cream Concrete 0.00 Negative
497 Area 1-1 Wall B Cream Concrete 0.01 Negative
498 Area 1-1 Wall C Cream Concrete 0.00 Negative
499 Area 1-1 Wall D Cream Concrete 0.00 Negative
500 Area 1-1 Column Brown Metal 0.21 Negative
501 Area 1-1 Column Base Brown Concrete 0.00 Negative
502 Area 1-1 Floor Brown Concrete 0.00 Negative
503 Area 1-1 Partition Brown Wood 0.00 Negative
504 Area 1-1 Shelve Blue Wood 0.02 Negative
505 Area 1-1 Ceiling Blue Wood 0.00 Negative
506 Area 1-2 Door Brown Wood 0.00 Negative
507 Area 1-2 Door Frame Brown Wood 0.00 Negative
508 Area 1-2 Floor Tile Gray Ceramic 0.01 Negative
509 Area 1-2 Wall Tile White Ceramic 0.01 Negative
510 Area 1-2 Wall A Cream Concrete 0.00 Negative
511 Area 1-2 Wall B Cream Concrete 0.00 Negative
512 Area 1-2 Wall C Cream Concrete 0.02 Negative
513 Area 1-2 Wall D Cream Concrete 0.00 Negative
514 Area 1-2 Window Shutter White Metal 0.00 Negative
515 Area 1-2 Toilet White Ceramic 0.03 Negative
516 Area 1-2 Lavatory White Ceramic 0.02 Negative
517 Area 1-2 Urinal White Ceramic 0.02 Negative
518 Area 1-3 Wall B Cream Concrete 0.00 Negative
519 Area 1-3 Column White Concrete 0.00 Negative
520 Area 1-3 Beam White Concrete 0.00 Negative
521 Area 1-3 Gate Brown Metal 0.02 Negative
522 Area 1-3 Window Shutter White Metal 0.00 Negative
523 Area 1-3 Column Cream Metal 0.02 Negative
524 Area 1-3 Column Base Cream Concrete 0.00 Negative
525 Area 1-4 Wall A Gray Wood 0.00 Negative
526 Area 1-4 Wall B Gray Wood 0.00 Negative
527 Area 1-4 Wall C Gray Wood 0.00 Negative
528 Area 1-4 Wall D Gray Wood 0.01 Negative
529 Area 1-4 Window Shutter White Metal 0.00 Negative
530 Area 1-4 Door Cream Wood 0.00 Negative
531 Area 1-4 Door Frame Cream Wood 0.00 Negative
532 Area 1-5 Floor Line Yellow Concrete 0.00 Negative
533 Area 1-5 Wall B White Concrete 0.02 Negative
534 Area 1-5 Lower Wall White Concrete 0.01 Negative
535 Area 1-5 Wall D White Concrete 0.00 Negative
536 Area 1-5 Beam Green Metal 0.00 Negative
537 Area 1-5 Column Gray Metal 0.00 Negative
538 Area 1-6 Wall A Green Concrete 0.00 Negative
539 Area 1-6 Wall B Green Concrete 0.03 Negative
540 Area 1-6 Wall C Green Concrete 0.00 Negative
541 Area 1-6 Wall D Green Concrete 0.01 Negative
542 Area 1-6 Door Green Metal 0.00 Negative
543 Area 1-6 Door Frame Green Metal 0.00 Negative
544 Exterior Area Wall A Cream Concrete 0.03 Negative
545 Exterior Area Wall A Cream Wood 0.00 Negative
546 Exterior Area Wall B Cream Concrete 0.00 Negative
547 Exterior Area Column Cream Metal 0.07 Negative
548 Exterior Area Column Base Cream Metal 0.00 Negative
549 Exterior Area Soffit White Wood 0.01 Negative
550 Exterior Area Wall C Cream Concrete 0.00 Negative
551 Exterior Area Column Cream Metal 0.00 Negative
552 Exterior Area Column Base Cream Metal 0.02 Negative
553 Exterior Area Wall D White Concrete 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Structure #054 LBP Inspector: Dilia Rosado
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
554 Exterior Area Column White Metal 0.02 Negative
555 Exterior Area Column Base White Metal 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Structure #054 LBP Inspector: Dilia Rosado
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
556 Area 1-1 Gate White Metal 0.00 Negative
557 Area 1-1 Wall A Cream Concrete 0.00 Negative
558 Area 1-1 Wall B Cream Concrete 0.01 Negative
559 Area 1-1 Wall C Cream Concrete 0.03 Negative
560 Area 1-1 Wall D Cream Concrete 0.00 Negative
561 Area 1-1 Column Red Metal 0.00 Negative
562 Exterior Area Wall A Cream Concrete 0.00 Negative
563 Exterior Area Wall B Cream Concrete 0.00 Negative
564 Exterior Area Wall C Cream Concrete 0.02 Negative
565 Exterior Area Wall D Cream Concrete 0.00 Negative
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Structure #5 LBP Inspector: Dilia Rosado
Sample ID. Functional Space Location Color Subst.
XRF Reading mg/cm2 Pos/Neg Comments
566 Calibration 1.00
567 Calibration 1.00
568 Calibration 1.00
569 Exterior Side A Pipeline Base Yellow Concrete 0.00 Negative
570 Exterior Side A Bollard Yellow Metal 0.00 Negative
571 Exterior Side A Flag Base Yellow Concrete 0.00 Negative
572 Exterior Side A Parking Line Yellow Concrete 0.00 Negative
573 Exterior Side D Bollard Yellow Metal 5.30 Positive
574 Exterior Side D Bollard Yellow Metal 0.00 Negative
575 Exterior Side D Parking Line Yellow Concrete 0.00 Negative
576 Exterior Side D Parking Line Yellow Concrete 0.00 Negative
577 Exterior Side D Bollard Yellow Metal 0.00 Negative
578 Exterior Side D Light Pole Yellow Wood 5.60 Positive
579 Exterior Side D Light Pole White Wood 0.00 Negative
580 Exterior Side D Water Valve Green Metal 0.00 Negative
581 Exterior Side D Light Pole Yellow Wood 4.90 Positive
582 Exterior Side D Light Pole Yellow Wood 5.90 Positive
583 Exterior Side C Light Pole Gray Metal 2.10 Positive
584 Exterior Side C Canon Red Metal 5.60 Positive
585 Exterior Side C Canon Black Metal 4.10 Positive
586 Exterior Side B Fence Pole Yellow Metal 3.30 Positive
587 Exterior Side B Fence Pole Yellow Metal 2.90 Positive
588 Exterior Side A Gate Brown Metal 0.00 Negative
589 Exterior Side A Portal Brown Concrete 0.00 Negative
590 Exterior Side A Wheel Stop Yellow Concrete 0.00 Negative
591 Exterior Side A Pav Mal White Concrete 0.00 Negative
592 Exterior Side A Pav Mal Yellow Concrete 0.03 Negative
593 Exterior Side A Window Shutter Yellow Concrete 0.00 Negative
594 Exterior Side A Pavement Marking Yellow Concrete 0.00 Negative
595 Exterior Side A Parking Line Yellow Concrete 0.00 Negative
596 Exterior Side A Parking Line Yellow Concrete 0.03 Negative
597 Exterior Side A Parking Line Blue Concrete 0.00 Negative
598 Exterior Side A Parking Line Yellow Concrete 0.00 Negative
599 Exterior Side A Window Shutter Yellow Concrete 0.02 Negative
600 Exterior Side A Pavement Marking Blue Concrete 0.00 Negative
601 Calibration 1.00
602 Calibration 1.00
603 Calibration 1.00
Various Building Areas- DPW at Campamento Santiago, Salinas PR CLIENT: PRNG
Site LBP Inspector: Harry Peña
APPENDIX C
XRF Performance Characteristic
Sheet
Niton XLp 300, 9/24/2004, ed. 1
Performance Characteristic Sheet
EFFECTIVE DATE: September 24, 2004 EDITION NO.: 1
MANUFACTURER AND MODEL:
Make: Niton LLC
Tested Model: XLp 300
Source:
Cd
Note: This PCS is also applicable to the equivalent model variations indicated below, for the Lead-in-Paint K+L variable reading time mode, in the XLi and
XLp series:
XLi 300A, XLi 301A, XLi 302A and XLi 303A.
XLp 300A, XLp 301A, XLp 302A and XLp 303A.
XLi 700A, XLi 701A, XLi 702A and XLi 703A.
XLp 700A, XLp 701A, XLp 702A, and XLp 703A.
Note: The XLi and XLp versions refer to the shape of the handle part of the instrument. The differences in the model numbers reflect other modes available, in addition to Lead-in-
Paint modes. The manufacturer states that specifications for these instruments are identical for the source, detector, and detector electronics relative to the Lead-in-Paint mode.
FIELD OPERATION GUIDANCE
OPERATING PARAMETERS:
Lead-in-Paint K+L variable reading time mode.
XRF CALIBRATION CHECK LIMITS:
0.8 to 1.2 mg/cm (inclusive)
The calibration of the XRF instrument should be checked using the paint film nearest 1.0 mg/cm in the NIST
Standard Reference Material (SRM) used (e.g., for NIST SRM 2579, use the 1.02 mg/cm film).
If readings are outside the acceptable calibration check range, follow the manufacturer's instructions to bring the instruments into control before XRF testing proceeds.
SUBSTRATE CORRECTION:
For XRF results using Lead-in-Paint K+L variable reading time mode, substrate correction is not needed for:
Brick, Concrete, Drywall, Metal, Plaster, and Wood
INCONCLUSIVE RANGE OR THRESHOLD:
K+L MODE
READING DESCRIPTION
SUBSTRATE THRESHOLD
(mg/cm2)
Results not corrected for substrate bias on any substrate
Brick
Concrete
Drywall
Metal
Plaster
Wood
1.0
1.0
1.0
1.0
1.0
1.0
BACKGROUND INFORMATION
EVALUATION DATA SOURCE AND DATE:
This sheet is supplemental information to be used in conjunction with Chapter 7 of the HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing ("HUD Guidelines"). Performance parameters shown on this sheet are calculated from the EPA/HUD evaluation using archived building components. Testing was conducted in August 2004 on 133 testing combinations. The instruments that were used to perform the testing had new sources; one instrument’s was installed in November 2003 with
40 mCi initial strength, and the other’s was installed June 2004 with 40 mCi initial strength.
OPERATING PARAMETERS:
Performance parameters shown in this sheet are applicable only when properly operating the instrument using the manufacturer's instructions and procedures described in Chapter 7 of the HUD Guidelines.
SUBSTRATE CORRECTION VALUE COMPUTATION:
Substrate correction is not needed for brick, concrete, drywall, metal, plaster or wood when using Lead-in-
Paint K+L variable reading time mode, the normal operating mode for these instruments. If substrate correction is desired, refer to Chapter 7 of the HUD Guidelines for guidance on correcting XRF results for substrate bias.
EVALUATING THE QUALITY OF XRF TESTING:
Randomly select ten testing combinations for retesting from each house or from two randomly selected units in multifamily housing. Use the K+L variable time mode readings.
Conduct XRF retesting at the ten testing combinations selected for retesting.
Determine if the XRF testing in the units or house passed or failed the test by applying the steps below.
Compute the Retest Tolerance Limit by the following steps:
Determine XRF results for the original and retest XRF readings. Do not correct the original or retest results for substrate bias. In single-family housing a result is defined as the average of three readings. In multifamily housing, a result is a single reading.
Therefore, there will be ten original and ten retest XRF results for each house or for the two selected units.
Calculate the average of the original XRF result and retest XRF result for each testing combination.
Square the average for each testing combination.
Add the ten squared averages together. Call this quantity C.
Multiply the number C by 0.0072. Call this quantity D.
Ad…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .