Atch 23 - TELECOM 1 of 2 - DRAWINGS.pdf

PDF 12 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction - Marion Federal contract opportunity
Solicitation number
36C77622B0040
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This federal contract opportunity solicitation involves infrastructure upgrades and renovations at the Department of Veterans Affairs Marion facility. The project scope includes electrical, bonding, UPS, building management system interfaces, HVAC, communication, physical security upgrades, and fiber infrastructure backbone campus wide within and between buildings, including modification to impacted roads, walks, grading and drainage, and other existing utilities. Data Center WAN updates and hazardous material abatement are also required. Offerors are to respond to solicitation number 36C77622B0040 by the specified deadline for consideration of award.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction - Marion, newest first.
File Type Posted
36C77622B0040 0005.pdf PDF
Clarifications - Marion.pdf PDF
Atch 27 - Construction Wage Rates - Grant 8-19-22.pdf PDF
03 30 00 - Cast-In-Place Concrete.pdf PDF
Technical Questions - FINAL - Marion 8-11-22.pdf PDF
36C77622B0040 0004.pdf PDF
Atch 27 - Construction Wage Rates - Grant 8-12-22.pdf PDF
Atch 27 - Construction Wage Rates - Grant 7-15-22.pdf PDF
36C77622B0040 0003.pdf PDF
36C77622B0040 0002.pdf PDF
36C77622B0040 0001.pdf PDF
Atch 27 - Construction Wage Rates - Grant 7-8-22.pdf PDF
Site Visit Sign-in Sheet - Marion 7-11-22.pdf PDF
Atch 2 - DRAWINGS SHEET INDEX.pdf PDF
Atch 6 - ARCH 4 of 4 - DRAWINGS.pdf PDF
Atch 17 - MECH 3 of 7 - DRAWINGS.pdf PDF
Atch 18 - MECH 4 of 7 - DRAWINGS.pdf PDF
Atch 19 - MECH 5 of 7 - DRAWINGS.pdf PDF
Atch 28 - Contractor Safety - Environmental Form.docx DOCX document
Atch 29 - Site Visit Instructions.pdf PDF
Atch 1 - SPECIFICATIONS.pdf PDF
Atch 4 - ARCH 2 of 4 - DRAWINGS.pdf PDF
Atch 5 - ARCH 3 of 4 - DRAWINGS.pdf PDF
Atch 9 - ELEC 1 of 3 - DRAWINGS.pdf PDF
Atch 10 - ELEC 2 of 3 - DRAWINGS.pdf PDF
Atch 12 - GENERAL - DRAWINGS.pdf PDF
Atch 16 - MECH 2 of 7 - DRAWINGS.pdf PDF
Atch 20 - MECH 6 of 7 - DRAWINGS.pdf PDF
Atch 27 - Construction Wage Rates - Grant 6-10-22.pdf PDF
Atch 7 - CIVIL 1 of 2 - DRAWINGS.pdf PDF
Atch 11 - ELEC 3 of 3 - DRAWINGS.pdf PDF
Atch 13 - HAZARDOUS ASBESTOS - DRAWINGS.pdf PDF
Atch 14 - HAZARDOUS LEAD BASED PAINT - DRAWINGS.pdf PDF
Atch 22 - STRUCTURAL - DRAWINGS.pdf PDF
Atch 24 - TELECOM 2 of 2 - DRAWINGS.pdf PDF
Atch 25 - COVID-19 Safety Protocols 12-14-21.pdf PDF
Atch 15 - MECH 1 of 7 - DRAWINGS.pdf PDF
36C77622B0040 - 6-27-22.pdf PDF
Atch 3 - ARCH 1of 4 - DRAWINGS.pdf PDF
Atch 8 - CIVIL 2 of 2 - DRAWINGS.pdf PDF
Atch 26 - Limitations on Subcontracting - Construction.docx DOCX document
Atch 21 - MECH 7 of 7 - DRAWINGS.pdf PDF
Show all 42

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TELECOMMUNICATIONS ABBREVIATIONS

ABBREVIATION DESCRIPTION

REFER TO OTHER SCHEDULES AND NOTES FOR ADDITIONAL ABBREVIATIONS.

MOUNTING HEIGHT TO CENTERLINE (ABOVE FINISHED FLOOR)

ABOVE FINISHED FLOOR

CEILING

COPPER

DATA (WHEN APPLIED TO COMMUNICATIONS OUTLET)

DEMO (WHEN APPLIED TO EXISTING/DEMO ITEMS)

EXISTING

MAXIMUM

MINIMUM

NOT IN CONTRACT

PARTIAL

RELOCATE

TYPICAL

UNLESS NOTED OTHERWISE

VOICE

WALL PHONE

WIRE

WEATHER RESISTANT

AFF

C

CU

D

D

E

MAX

MIN

NIC

PART

R

TYP

UNO

V

W

W

WR

A. REFER TO VA OIT "INFRASTRUCTURE STANDARD FOR TELECOMMUNICATIONS SPACES VERSION 3.1" FOR ADDITIONAL REQUIREMENTS INCLUDING MANUFACTURER AND MODEL NUMBERS FOR THE BASIS OF DESIGN EQUIPMENT. ALL EQUIPMENT PROVIDED AS PART OF THIS PROJECT MUST BE EQUIVALENT TO THE BASIS OF DESIGN EQUIPMENT

LISTED.

B. FOR ALL CONDUIT AND OTHER ITEMS PENETRATING A FIRE RATED WALL, PROVIDE UL LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM THAT IS SPECIFIC TO THE WALL CONSTRUCTION ASSEMBLY AND COMPLIANT WITH ASTM E814. INSTALL SYSTEM IN STRICT COMPLIANCE WITH THE FIRE STOPPING MANUFACTURER’S U.L.

APPROVED DETAIL. WHERE EXISTING WALLS ARE BEING UPGRADED TO FIRE RATED WALLS OR THE FIRE RATING IS BEING MODIFIED, PROVIDE U.L. LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM FOR ALL NEW AND EXISTING PENETRATIONS. REFER TO THE ARCHITECTURAL LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED WALLS.

C. PROVIDE ADDITIONAL SUPPORTS AS REQUIRED TO INDEPENDENTLY SUPPORT ALL EXISTING TO REMAIN CABLING.

D. PROVIDE ONE (1) CATEGORY 6A CABLE TO EACH UPS WITHIN PROJECT. CENTRALIZED UPS'S ARE SHOWN ON THE

ELECTRICAL DRAWING SET AND RACK MOUNTED UPS'S ARE SHOWN ON THE TELECOMMUNICATIONS ROOM RACK ELEVATIONS FOR EACH ROOM. UPS'S SHALL BE CONNECTED TOGETHER IN A CENTRALIZED UPS MONITORING

SYSTEM.

E. PROVIDE ONE (1) CATEGORY 6A CABLE TO EACH NEW PANELBOARD, DISTRIBUTION BOARD, AND SWITCHBOARD WITHIN PROJECT. PANELS SHALL BE CONNECTED TOGETHER IN A CENTRALIZED ELECTRICAL METERING SYSTEM.

F. IT IS THE CONTRACTORS RESPONSIBILITY TO ENSURE ALL VOICE AND DATA CABLING AND ASSOCIATED OUTLETS ARE UPGRADED AS A PART OF THIS PROJECT. DRAWINGS REFLECT GENERAL DEVICE OUTLET LOCATIONS BASED ON FIELD OBSERVATIONS AND CABLE QUANTITIES BASED ON SURVEYS PROVIDED BY THE VA OIT TEAM. FIELD INVESTIGATIONS DURING CONSTRUCTION WILL BE REQUIRED TO CONFIRM EXACT QUANTITIES AND DEVICE

LOCATIONS.

G. CABLE QUANTITIES INDICATED FOR EACH BUILDING ARE APPROXIMATE BASED ON FIELD OBSERVATIONS. ACCOUNT FOR 20% ADDITIONAL CABLES, DEVICES, AND PATCH PANELS IN ORDER TO ACCOMMODATE THE FULL SCOPE OF THE

PROJECT.

H. IT IS THE CONTRACTORS RESPONSIBILITY TO ENSURE ALL ENTRANCE, BACKBONE, AND HORIZONTAL CABLING IS TERMINATED EACH END, TESTED, AND LABELED PER SPECIFICATIONS. FIBER OPTIC CABLING SHALL BE TERMINATED WITHIN RACK MOUNT FIBER ENCLOSURES EACH END. EXACT PART AND MODEL NO WILL NOT BE IDENTIFIED WITHIN RACK ELEVATIONS OR SCHEMATICS. REFER TO SPECIFICATIONS. UTP CABLING SHALL BE TERMINATED EACH END ON SPECIFIED CAT 6A PATCH PANELS WITHIN THE TRS AND SPECIFIED CAT 6A JACKS AT THE USER OUTLET.

I. CABLE QUANTITIES INDICATED FOR EACH BUILDING ARE APPROXIMATE BASED ON FIELD OBSERVATIONS AND READINESS INFRASTRUCTURE SELF-ASSESSMENTS PROVIDED BY THE VA. SOME LOCATIONS WERE UNABLE TO BE SURVEYED FOR EXISTING COMMUNICATIONS OUTLETS AND CABLING DUE TO PATIENT CARE. CONTRACTOR SHALL ACCOUNT FOR ADDITIONAL CABLES REQUIRED. CONTRACTOR SHALL ACCOUNT FOR AN ADDITIONAL 20% OF CABLES, DEVICES, AND PATCH PANELS INDICATED ON DRAWINGS IN ORDER TO ACCOMMODATE THE FULL SCOPE OF THE

PROJECT WITHIN BASE BID.

J. EXISTING CEILINGS THROUGHOUT CORRIDORS AND ROOMS WITH EXISTING CABLING WILL NEED TO BE REMOVED AND REPLACED TO ACCOMMODATE CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR IDENTIFICATION OF SCOPE OF WORK ASSOCIATED WITH THIS REMOVAL WITHIN BASE BID. WHERE EXISTING CEILINGS ARE LAYIN TILE, GRID

SYSTEM MAY REMAIN IN PLACE AND ONLY THE EXISTING TILES WILL REQUIRE REMOVAL AND

REPLACEMENT. EXISTING CEILING MOUNTED COMPONENTS SHALL BE TEMPORARILY SUPPORTED AND BE REINSTALLED IN NEW CEILINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR COST OF REPLACEMENT OF CEILING ELEMENTS THAT ARE DAMAGED OR DESTROYED DURING THE PROJECT. REFER TO ARCHITECTURAL DRAWINGS FOR FURTHER INFORMATION. COORDINATE WITH OWNER FOR PROCUREMENT OF REPLACEMENT CEILING TILES OR

OTHER ELEMENTS.

K. TELECOM DEVICES SHALL BE REPLACED AT ALL LOCATIONS WITH A TWO (2) PORT DATA DEVICE AS INDICATED PER THESE CONSTRUCTION DOCUMENTS. WHERE AN EXISTING TELECOM OUTLET CURRENTLY HAS A COMBINATION OF PORTS WHETHER DATA OR ANALOG WITH A TOTAL CABLE QUANTITY GREATER THAN TWO (2) DATA, THE CONTRACTOR SHALL DOCUMENT WHAT NUMBER OF PORTS IS BEING UTILIZED BY ANALOG OR DATA CONNECTIONS.

ANALOG PORTS CURRENTLY BEING UTILIZED SHALL BE EXISTING TO REMAIN AND SHALL BE REINSTALLED IN THE NEW FACEPLATE PROVIDED BY THE CONTRACTOR. ASSOCIATED WALL FIELD SERVING THAT DEVICE WILL REMAIN REGARDLESS IF SHOWN TO BE DEMOLISHED OR REMAIN EXISTING ON THE DOCUMENTS. DATA PORTS CURRENTLY BEING UTILIZED BEYOND A QUANTITY OF TWO (2), SHALL BE REPLACED WITH NEW CABLING AND JACKS PER THE DOCUMENTS. WHERE AN EXISTING TELECOM DEVICE HAS UNUSED ANALOG OR DATA PORTS BEYOND TWO (2) DATA PORTS, THOSE JACKS AND ASSOCIATED CABLING SHALL BE REMOVED. WHERE EXISTING ANALOG WALL FIELDS ARE COMPLETELY ABANDONED AS A PART OF THIS PROJECT, WALL FIELD COMPONENTS AND BACKBONE CABLING SHALL

BE REMOVED IN THEIR ENTIRETY.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

TELECOMMUNICATIONS GENERAL NOTES:

LEGEND: (LOW VOLTAGE COORDINATION LEGEND)

CF: CONTRACTOR FURNISHED

CI: CONTRACTOR INSTALLED

OF: OWNER FURNISHED

OI: OWNER INSTALLED

REMARKS: (LOW VOLTAGE COORDINATION LEGEND)

1. PATCH PANELS SHALL BE CONTRACTOR FURNISHED AND CONTRACTOR INSTALLED PER

SPECIFICATION. REFER TO TYPICAL COMMUNICATION TERMINATION DETAIL.

2. ACCESS CONTROL SYSTEMS FOR TELECOMMUNICATIONS CLOSETS IS AN EXTENSION OF AN

EXISTING STANLEY SECURITY SYSTEM. NEW DEVICES SHALL FUNCTION AS AN EXTENSION

OF THE EXISTING SYSTEM. VENDOR CONTACT; STANLEY SECURITY (MYRA SCHNITZLER)

(317) 922-6565

3. SECURITY SURVEILLANCE (CCTV) SYSTEM IS AN EXTENSION OF AN EXISTING AXIS

COMMUNICATIONS SYSTEM. NEW DEVICES SHALL FUNCTION AS AN EXTENSION OF THE

EXISTING SYSTEM. VENDOR CONTACT; WILLIAMS ELECTRONICS (SCOTT KEEN) (260)

918-2255

4. PATCH CABLES TO BE PROVIDE BY CONTRACTOR PER TYPICAL COMMUNICATION

TERMINATION DETAIL. CERNER WILL FURNISH PATCH CABLES FOR CABLING FROM RACK TO

SWITCH AND DEVICE TO WALL AND SHALL BE INSTALLED BY THE CONTRACTOR WITH OIT

PRESENCE.

GENERAL NOTES: (LOW VOLTAGE COORDINATION LEGEND)

A. REFER TO SYMBOL LEGENDS AND SPECIFICATIONS FOR SPECIFIC REQUIREMENTS.

B. COORDINATE ROUGH-IN REQUIREMENTS WITH FINAL EQUIPMENT SELECTION FOR ALL

SYSTEMS.

C. COORDINATE ROUGH-IN REQUIREMENTS WITH OWNER FOR OWNER FURNISHED SYSTEMS.

D. CONDUITS SHALL ROUTE CONCEALED INSIDE WALL TO ABOVE NEAREST ACCESSIBLE

CEILING SPACE, UNLESS OTHERWISE INDICATED.

E. WHERE CABLING IS CONTRACTOR FURNISHED AND CONTRACTOR INSTALLED, TERMINATE

AND TEST ALL CABLING PER SPECIFICATION.

A. THE INTENT OF THE DEMOLITION DRAWINGS IS TO DEFINE THE SCOPE OF ELECTRICAL DEMOLITION WORK. PROVIDE

DEMOLITION FOR ITEMS AS SHOWN.

B. ITEMS INDICATED WITH A SUBSCRIPT 'E' SHALL BE EXISTING TO REMAIN (E-EXISTING). ITEMS INDICATED WITH A SUBSCRIPT 'D' OR SHOWN DASHED SHALL BE REMOVED (D-DEMOLITION). ITEMS INDICATED WITH A SUBSCRIPT 'R'

SHALL BE REMOVED, STORED, AND REINSTALLED PER NEW WORK (R-RELOCATION).

C. THESE DRAWINGS DO NOT IDENTIFY EACH INDIVIDUAL ITEM TO BE REMOVED. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING ITEMS WHICH MUST BE REMOVED TO FACILITATE NEW CONSTRUCTION. SEE ARCHITECTURAL PLANS FOR EXACT LIMITS OF DEMOLITION AND CONSTRUCTION. THESE PLANS ARE BASED ON PAST PROJECT DRAWINGS AND SITE OBSERVATIONS. THE DRAWINGS ARE PROVIDED TO THE CONTRACTOR AS AN AID IN DETERMINING THE EXTENT OF WORK REQUIRED FOR DEMOLITION AND TO PROVIDE GENERAL INFORMATION ABOUT EXISTING SYSTEMS. THESE DRAWINGS MAY NOT BE ACCURATE IN ALL AREAS. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS AND IS ENCOURAGED TO REVIEW FACILITY DRAWINGS PRIOR

TO THE BID DATE.

D. THE OWNER SHALL HAVE FIRST SALVAGE RIGHTS TO ALL ITEMS REMOVED. IF OWNER REFUSES SALVAGE, CONTRACTOR IS RESPONSIBLE FOR DISPOSAL.

E. WHERE EXISTING WALLS ARE TO BE REMOVED, ALL ASSOCIATED TELECOMMUNICATIONS EQUIPMENT SHALL BE REMOVED. SEE ARCHITECTURAL DRAWINGS FOR WALLS TO BE REMOVED. ABANDON CONCEALED CONDUITS WHERE WALLS ARE NOT REMOVED. CONCEALED CONDUITS MAY BE REUSED WHERE AVAILABLE. WHERE EXISTING CABLING IS TO BE DEMOLISHED AND NOT REUSED, REMOVE CABLES AND ASSOCIATED ACCESSIBLE RACEWAYS/CONDUIT BACK TO THE SOURCE. WHERE EXISTING CONDUITS TO BE DEMOLISHED ARE EMBEDDED IN CONCRETE FLOORS OR WALLS, CONDUITS MAY BE ABANDONED IN PLACE. EXISTING CABLES SHALL BE REMOVED BACK TO SOURCE AND CONDUITS SHALL BE CUT AT SURFACE OF CONCRETE AND FILLED. EXISTING BACK BOXES AND CONDUITS REMAINING FROM DEVICES BEING REMOVED MAY BE UTILIZED FOR NEW DEVICES WHERE LOCATIONS PERMIT. REMOVE AND PATCH

WHERE BOXES ARE NOT REUSED.

F. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL ELECTRICAL DEMOLITION ITEMS. DISCONNECT AND REMOVE ELECTRICAL DEVICES, EQUIPMENT AND ASSOCIATED WIRING AS REQUIRED TO ACCOMMODATE NEW WORK. IF THE CONTRACTOR IS UNCLEAR REGARDING A SPECIFIC ITEM TO REMAIN OR BE REMOVED, THE CONTRACTOR SHALL SEEK

CLARIFICATION FROM THE ARCHITECT.

G. SYSTEMS SERVING ADJACENT AREAS AND ITEMS THAT REMAIN SHALL BE MAINTAINED AT ALL TIMES. MODIFY SYSTEMS AS REQUIRED THROUGHOUT CONSTRUCTION TO MAINTAIN CONTINUITY OF SERVICE. DO NOT INTERRUPT SERVICE WITHOUT OWNER'S PRIOR WRITTEN APPROVAL. LIMIT DURATION OF INTERRUPTION ONLY TO THE TIME NECESSARY FOR DISCONNECTION AND IMMEDIATE RECONNECTION. INTERRUPTION TO SERVICE DEEMED BY OWNER AS ESSENTIAL MAY REQUIRE PREMIUM TIME AND SHALL BE INCLUDED WITH THE BID. EXTREME CARE SHALL BE TAKEN BY THE CONTRACTOR TO IDENTIFY EXISTING SYSTEM COMPONENTS ASSOCIATED WITH THESE SERVICES.

APPROPRIATE METHODS OF MARKING THESE SHALL OCCUR TO ELIMINATE THE POSSIBILITY OF ACCIDENTAL INTERRUPTION. FOR CONDUIT AND CABLING THAT CAN REMAIN, PROVIDE SUPPORT AS REQUIRED. RELOCATE

EXISTING JUNCTION BOXES THAT BECOME INACCESSIBLE DUE TO NEW WORK.

H. COORDINATE DEMOLITION WITH THE WORK OF OTHER TRADES. PROVIDE TEMPORARY SERVICES AS REQUIRED TO

ALLOW THE WORK OF OTHER TRADES TO PROCEED.

I. PROTECT EXISTING TELECOMMUNICATIONS EQUIPMENT THAT REMAINS. IF DAMAGED OR DISTURBED IN THE COURSE OF THE WORK, REMOVE DAMAGED PORTIONS AND INSTALL NEW PRODUCTS OF EQUAL CAPACITY, QUALITY, AND

FUNCTIONALITY.

J. PATCH AND REPAIR OPENINGS IN EXISTING WALLS AND FLOORS RESULTANT FROM SPECIFIED ELECTRICAL DEMOLITION. PATCH SHALL MATCH EXISTING CONSTRUCTION, FIRE RATING, AND FINISH. SEE ARCHITECTURAL

SPECIFICATIONS FOR MEANS AND METHODS.

K. THIS PROJECT WILL BE PHASED. SEE PROJECT MANUAL AND ARCHITECTURAL PLANS FOR DETAILS. SYSTEM SERVICES TO AREAS NOT IN THE CURRENT PHASE OF CONSTRUCTION SHALL BE MAINTAINED AT ALL TIMES.

L. WHERE DEMOLITION OF EQUIPMENT INVOLVES REMOVAL OF EQUIPMENT LOCATED ON CONCRETE HOUSEKEEPING PADS, PADS SHALL ALSO BE REMOVED AND FLOOR/GRADE SHALL BE FINISHED TO MATCH ADJACENT SURFACE.

M. ALL UNLABELED TELECOMMUNICATIONS DEVICES SHALL BE TRACED AS NEEDED WITH A LABEL PROVIDED.

N. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT OF ALL CABLING, PATHWAYS, AND SYSTEMS LOCATED ABOVE

CEILING THAT ARE REQUIRED TO BE MODIFIED AS A PART OF THE PROJECT. CONTRACTOR SHALL REPLACE ANY

ITEMS DAMAGED FROM TEMPORARY SUPPORT.

O. EXISTING ANALOG DEVICES ACTIVELY SERVING EQUIPMENT SHALL BE EXISTING TO REMAIN REGARDLESS IF SHOWN AS BEING REMOVED. CONNECTIONS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING. THE CONTRACTOR SHALL

FIELD VERIFY DURING CONSTRUCTION.

a. FAX, ELEVATORS, PATIENT TELEPHONES, BLUE PHONES, CODE BLUE DEVICES, FIRE ALARM, MEDICAL ANALOG

EQUIPMENT, PANIC DURESS, ETC.

P. WITHIN EXISTING SPACES THAT ARE TO BE DEMOLISHED TO BE CONVERTED INTO A TR OR MCR, REROUTE ANY

EXISTING LOW VOLTAGE CABLING OUTSIDE THE ROOM. SPLICE AND EXTEND CONDUCTORS AS REQUIRED. REPLACE

ANY CATEGORY CABLES NEEDING TO BE REROUTED.

(ELECTRICAL DEMOLITION NOTES APPLY TO ALL ELECTRICAL DEMOLITION PLANS AND

ALL ELECTRICAL DEMOLITION WORK)

ELECTRICAL DEMOLITION GENERAL NOTES:

PHASING SEQUENCE LISTED BELOW IS FOR INFORMATION ONLY. CONTRACTOR SHALL BE RESPONSIBLE FOR DEVELOPING PROJECT SCHEDULE AND PHASING AND SHALL INCLUDE WORK REQUIRED TO ACCOMMODATE PHASING.

SUBMIT PHASING PLAN TO OWNER FOR REVIEW AND APPROVAL AND COORDINATE WITH OWNER PRIOR TO BEGINNING

CONSTRUCTION.

EXISTING ENTRANCE FACILITY ROOM: LOCATED IN BUILDING 127

EXISTING MAIN COMPUTER ROOMS (QTY 2): LOCATED IN BUILDINGS 124 AND 127

NEW ENTRANCE FACILITY ROOM: LOCATED IN BUILDING 172

NEW MAIN COMPUTER ROOM: LOCATED IN BUILDING 15

A. NEW ENTRANCE FACILITY ROOM AND NEW MAIN COMPUTER ROOM: CONSTRUCT THE NEW ENTRANCE FACILITY ROOM AND THE NEW MAIN COMPUTER ROOM TO BE OPERATIONAL. ROUTE NEW TELECOMMUNICATIONS PROVIDER ENTRANCE CABLING FROM THE PROVIDER’S NEW ORIGINATION POINT ON THE CAMPUS SITE TO THE NEW ENTRANCE FACILITY ROOM, AND SUBSEQUENT CABLING FROM THERE TO THE NEW MAIN COMPUTER ROOM. PROVIDE FIBER INTERCONNECTIONS BETWEEN THE EXISTING MAIN COMPUTER ROOMS AND THE NEW MAIN COMPUTER ROOM FOR PARALLEL NETWORK OPERATIONS OF THE EXISTING AND NEW DISTRIBUTION NETWORKS FOR THE DURATION OF CONSTRUCTION. COORDINATE WITH THE VA FOR THEIR RELOCATION EQUIPMENT FROM THE EXISTING MAIN COMPUTER ROOM TO THE NEW MAIN COMPUTER ROOM. MAINTAIN THE EXISTING ENTRANCE FACILITY ROOM AND EXISTING MAIN COMPUTER ROOM AS CURRENTLY CONSTRUCTED TO BE OPERATIONAL AND ACTIVE IN A PARALLEL

CONDITION UNTIL THE END OF THE PROJECT.

B. SITE FIBER TO BUILDINGS: CONSTRUCT REDUNDANT SITE FIBER LOOP FROM NEW MAIN COMPUTER ROOM TO ALL BUILDINGS. MAINTAIN EXISTING FIBER PATHWAYS FROM THE EXISTING MAIN COMPUTER ROOM AS CURRENTLY

CONSTRUCTED UNTIL THE END OF THE PROJECT.

C. NEW TELECOMMUNICATIONS ROOMS AND RESUPPORTED EXISTING TELECOMMUNICATIONS ROOMS: CONSTRUCT NEW TELECOMMUNICATIONS ROOMS TO BE OPERATIONAL. RESUPPORT EXISTING TELECOMMUNICATIONS ROOMS TO REMAIN WITH NEW RACKS AND BACKBONE CABLING. PROVIDE NEW A/B POWER PANELS AND GROUNDING IN NEW AND EXISTING TO REMAIN ROOMS. POWER ALL TELECOMMUNICATIONS ROOM LOADS FROM THE NEW PANELS.

ROUTE NEW PRIMARY AND REDUNDANT FIBER TO NEW TELECOMMUNICATIONS ROOMS AND EXISTING TO REMAIN TELECOMMUNICATIONS ROOMS, FROM THE NEW MAIN COMPUTER ROOM. UPON ACTIVATION OF THESE NEW AND RESUPPORTED ROOMS, BOTH THE NEW AND EXISTING DISTRIBUTION NETWORKS WILL BE SIMULTANEOUSLY ACTIVE TO ALLOW FOR RE-CABLING THE PROGRESSIVE TRANSITION FROM THE EXISTING NETWORK TO THE NEW NETWORK

FOR EACH AREA OUTLET INDIVIDUALLY.

D. EXISTING TELECOMMUNICATIONS ROOMS: MAINTAIN THE EXISTING TELECOMMUNICATIONS ROOMS AND EXISTING BACKBONE CABLING UNTIL THE AREA OUTLETS BEING SERVED BY EACH RESPECTIVE TELECOMMUNICATIONS ROOM

HAS BEEN TRANSITIONED TO THE NEW TELECOMMUNICATIONS ROOM.

E. RE-CABLING: FOR NEW TELECOMMUNICATIONS ROOMS, PROVIDE NEW CABLES FROM THE EXISTING AREA OUTLETS TO THE NEW RACKS. REMOVE EXISTING CATEGORY 5E OR LOWER CABLING AFTER NEW CABLES HAVE BEEN PULLED TO THE OUTLETS TO MAINTAIN OPERATIONAL CAPABILITY OF THE SPACES TO THE GREATEST EXTENT POSSIBLE.

F. EXISTING CABLE REMOVAL: AFTER NEW CABLING HAS BEEN INSTALLED AND ACTIVATED, REMOVE EXISTING BACKBONE CABLING AND EXISTING AREA OUTLET CABLING FROM TELECOMMUNICATIONS ROOMS BEING ABANDONED. REMOVE UNUSED CABLING IN PREVIOUSLY ABANDONED TELECOMMUNICATIONS ROOMS.

G. INTERBUILDING BACKBONE: REPLACE THE EXISTING INTERBUILDING BACKBONE CABLING WITH NEW BACKBONE CABLING. REUSE THE EXISTING BACKBONE PATHWAYS FOR NEW BACKBONE CABLE INSTALLATION. SIDE A FIBER ROUTE SHALL UTILIZE EXISTING PATHWAYS. EXISTING FIBER UTILIZING EXISTING PATHWAYS SHALL NOT BE REMOVED UNTIL NEW FIBER ROUTE B IS COMPLETE AND NEW TELECOMMUNICATIONS ROOMS ARE ONLINE AND FUNCTIONING.

H. EXISTING TELECOMMUNICATIONS PROVIDER: REMOVE THE TELECOMMUNICATIONS PROVIDER CABLING TO THE EXISTING ENTRANCE FACILITY ROOM AND SUBSEQUENT EXISTING BACKBONE CABLING FROM THERE TO THE EXISTING MAIN COMPUTER ROOMS. COORDINATE WITH THE VA AND REMOVE/RELOCATE ANY REMAINING ITEMS

FROM THE EXISTING MAIN COMPUTER ROOM. DEMOLISH THE EXISTING MAIN COMPUTER ROOM.

I. SERVER MIGRATION: WITH BOTH THE EXISTING AND NEW DISTRIBUTION NETWORKS BEING SIMULTANEOUSLY ACTIVE THROUGHOUT THE PROGRESSION OF RE-CABLINGS AND OUTLET TRANSITIONS, MIGRATION OF SERVERS FROM THE EXISTING SERVER ROOM TO THE NEW MAIN COMPUTER ROOM SHALL OCCUR BETWEEN THE TIME THAT THE NEW NETWORK IS ACTIVE (AND READY TO ACCEPT NEW CABLES), BUT BEFORE THE OLD NETWORK IS DEACTIVATED AND REMOVED. AT ALL TIMES, TWO (2) CORE SWITCHES NEED TO BE ACTIVE TO MAINTAIN UTILIZATION OF EXISTING SERVER ROOM AND NEW SERVER ROOM TO ACCOMMODATE PHASING OF SYSTEMS FROM OLD ROOM TO NEW

ROOM.

J. NETWORK ELECTRONICS COORDINATION: CONSIDERING THE ABOVE PHASING, COORDINATION WILL BE REQUIRED BETWEEN THE VA AND CABLING CONTRACTOR IN ORDER TO PROPERLY SEQUENCE THE ACQUISITION, CONFIGURATION, AND ACTIVATION OF NETWORK ELECTRONICS IN COORDINATION WITH THE ACTIVATION OF EACH NEW NETWORK DISTRIBUTION POINT, ACTIVATION OF EACH RE-CABLED OUTLET, AND THE SUBSEQUENT DEACTIVATION OF BOTH EXISTING OUTLET CABLES AND EXISTING NETWORK DISTRIBUTION POINTS.

(NOTES SHALL APPLY TO OVERALL PROJECT PHASING)

OVERALL PHASING NOTES:

1. WORK RESTRICTIONS IN OPERATIONAL ROOMS: WORK WITHIN EXISTING ROOMS (ENTRANCE FACILITY, MAIN COMPUTER ROOMS, TELECOMMUNICATIONS ROOMS) SHALL REQUIRE THE PRESENCE OF A VA ESCORT WHILE THE EXISTING ROOM IS STILL OPERATIONAL AND ACTIVE. WORK WITHIN NEW ROOMS (ENTRANCE FACILITY, MAIN COMPUTER ROOM, TELECOMMUNICATIONS ROOMS) SHALL REQUIRE THE PRESENCE OF A VA ESCORT ONCE THE

NEW ROOM BECOMES OPERATIONAL AND ACTIVE.

2. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR WORK RESTRICTIONS WITHIN EACH BUILDING FOR TIME OF DAY AVAILABILITY OF SPACES AND LEVEL OF INFECTION CONTROL REQUIRED BY THE CONTRACTOR.

CONTRACTOR SHALL ACCOUNT FOR OFF HOURS WORK REQUIRED.

(NOTES SHALL APPLY TO OVERALL PROJECT RESTRICTIONS)

WORK RESTRICTION NOTES:

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 04/15/2022

Sheet of

B

IM

/2

V A

M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.C A

M P

U S

M

A R

IO

N

R

.r v t

/1

/2

:3

:5

A

M

T000

TELECOMMUNICATIONS SYMBOLS

AND ABBREVIATIONS

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

JLK SSK

16181

1 313

ELECTRICAL MISC SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

CABLE TRAY PROVIDE CABLE TRAY AT LOCATIONS INDICATED ON PLANS. REFER TO FLOOR PLANS FOR TYPE DESIGNATION.

COORDINATE MOUNTING WITH OTHER TRADES AND REQUIREMENTS IN SPECIFICATION.

TYPE 'WIDTH x DEPTH", WIRE BASKET CABLE TRAY:

PROVIDE CABLE TRAY IN DIMENSION INDICATED ON FLOOR PLANS.

LOW VOLTAGE COORDINATION LEGEND

SYSTEMS

ROUGH-INS &

PATHWAYS

CABLING &

TERMINATIONS

DEVICES &

EQUIPMENT REMARKS

ACCESS CONTROL CF / CI CF / CI CF / CI 2

SECURITY SURVEILLANCE (CCTV) CF / CI CF / CI CF / CI 3

TELEVISION (CATV) CF / CI CF / CI OF / OI -

VOICE / DATA CF / CI CF / CI OF / OI 1,4

WIRELESS ACCESS POINTS CF / CI CF / CI OF / CI 1

SECURITY SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

ACCESS CONTROL DEVICE GENERAL:

PROVIDE ACCESS CONTROL COMPONENTS AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH ACCESS CONTROLLED DEVICE TYPE AT DOORS INDICATED. REFER TO FLOOR PLANS FOR DEVICE DESIGNATION. PROVIDE ROUGH-INS PER ACCESS CONTROL ROUGH-IN DETAIL. DOOR ACCESS COMPONENTS SHALL BE RATED FOR CONTINUOUS OPERATION IN THEIR INSTALLED PROJECT CONDITIONS AS REQUIRED IN SPECIFICATION SECTION 281300. COORDINATE REQUIRED CONDUITS TO DOOR FRAME AND WALL MOUNTED DEVICES WITH DOOR HARDWARE CONTRACTOR. PROVIDE SURFACE MOUNTED CONDUIT AND BACK BOX IN UNFINISHED AREAS. PROVIDE 20A 120V BRANCH CIRCUIT TO DOOR CONTROLLERS LOCATED WITHIN ACCESS CONTROL CABINET IN ASSOCIATED TR. PROVIDE FINAL CONNECTION OF 120V BRANCH CIRCUIT TO ALL POWER SUPPLIES REQUIRED FOR EACH DOOR FUNCTION. REFER TO E-SERIES ELECTRICAL FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATIONS. PROVIDE ACCESS CONTROL CABLING FROM DOOR CONTROLLER TO COMPONENTS REQUIRED BY THE DOOR HARDWARE SPECIFICATION INCLUDING BUT NOT LIMITED TO CARD READER, DOOR POSITION SWITCH, ELECTRIC STRIKE, ELECTRIFIED HINGE, DOOR RELEASE PUSH BUTTON, MAGNETIC LOCK, AND REQUEST TO EXIT. PROVIDE DOOR POSITION SWITCH AND REQUEST TO EXIT AT EACH ACCESS CONTROLLED DOOR, UNLESS PROVIDED BY DOOR HARDWARE CONTRACTOR. CONTRACTOR SHALL TERMINATE ACCESS CONTROL CABLING TO DEVICES AT DOOR LOCATION AND PROVIDE A 7'-0" PIGTAIL WITHIN TR AT ACCESS CONTROL CABINET WITH APPROPRIATE DEVICE LABEL. COORDINATE ALL TERMINATION REQUIREMENTS AND EXACT LOCATION OF TERMINATIONS WITH OWNER'S ACCESS CONTROL MANAGER. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTION 281300 INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, AND CABLING. WHERE DOOR IS ALSO SPECIFIED/SHOWN TO UTILIZE DOOR OPERATOR, PROVIDE INTERLOCK TO ALLOW AUTOMATIC DOOR OPENING FROM THE ACCESS CONTROL SYSTEM UPON SUCCESSFUL CARD READ. SUBMIT SHOP DRAWINGS FOR APPROVAL. PROVIDE FIRE ALARM SYSTEM CONNECTION FOR DOOR RELEASE UPON ALARM. INTEGRATE ACCESS CONTROL SYSTEM WITH DOOR OPERATORS, FIRE ALARM, WANDER PREVENTION, INTERCOM, AND DOOR HARDWARE. REFER TO ACCESS CONTROL AND ARCHITECTURAL DOOR HARDWARE SPECIFICATIONS FOR COORDINATION OF FEATURES, DEVICES, AND

CONNECTIONS REQUIRED.

ACCESS CONTROL PANEL CIRCUIT CONTROL PANEL TO 20A 120V BRANCH CIRCUIT IN LOCAL BRANCH PANEL (GENERATOR FEED WHEN BUILDING HAS GENERATOR BACKUP). REFER TO FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATIONS.

COORDINATE CONNECTION REQUIREMENTS WITH FINAL EQUIPMENT SELECTION AND PROVIDE NEMA 5-20

RECEPTACLE OR HARD-WIRED CONNECTION TO CABINET AS REQUIRED.

CREDENTIAL CARD READER GENERAL:

PROVIDE PROXIMITY CARD READER AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH CARD READER TYPE AT APPROXIMATE LOCATION INDICATED. REFER TO FLOOR PLANS FOR CARD READER DESIGNATION. PROVIDE ROUGH-IN PER ACCESS CONTROL ROUGH-IN DETAIL. WHERE SHOWN MOUNTED ON DOOR/WINDOW SYSTEM MULLION, PROVIDE MULLION MOUNT CARD READER SURFACE MOUNTED ON MULLION.

CABLING SHALL BE ROUTED RECESSED WITHIN MULLION TO ACCESSIBLE CEILING SPACE. COORDINATE INSTALLATION WITH MULLION MANUFACTURER. CARD READERS SHALL BE RATED FOR CONTINUOUS OPERATION IN THEIR INSTALLED PROJECT CONDITIONS AS REQUIRED IN SPECIFICATION SECTION 281300. SUBMIT SHOP DRAWINGS FOR APPROVAL. COORDINATE EXACT LOCATION OF CARD READER WITH ARCHITECT, ARCHITECTURAL INTERIOR ELEVATIONS, AND OTHER DOOR COMPONENTS INCLUDING BUT NOT LIMITED TO PUSH PLATE ACTUATORS, REQUEST TO EXIT PUSH BUTTONS, INTERCOM STATIONS, NURSE CALL CANCEL STATIONS, INTRUSION DETECTION KEYPADS, WANDER PREVENTION KEYPADS, AND INFANT PROTECTION KEYPADS. REFER TO ACCESS

CONTROL SYMBOL LEGEND DESCRIPTION FOR CABLING AND ADDITIONAL REQUIREMENTS.

TYPE ‘KEYPAD’, COMBINATION KEYPAD PROXIMITY CARD READER:

PROVIDE COMBINATION KEYPAD PROXIMITY CARD READER PER SPECIFICATION.

DOOR RELEASE PUSH BUTTON PROVIDE MOMENTARY CONTACT DOOR RELEASE PUSH BUTTON AT APPROXIMATE LOCATION INDICATED. PUSH BUTTON SHALL RELEASE DOORS OF SAME TYPE AS INDICATED ON FLOOR PLANS. PROVIDE 4" SQUARE BACK BOX MOUNTED [AT 48" AFF] [5" ABOVE BACKSPLASH AT DESK LOCATION INDICATED] WITH SINGLE GANG TRIM RING AND ONE (1) 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING FOR CABLING. PROVIDE DOOR RELEASE UPON ACTIVATION OF PUSH BUTTON. DOOR SHALL RETURN TO SECURED STATE UPON RELEASE OF PUSH BUTTON.

DEVICE SHALL HAVE A PUSH BUTTON DEDICATED TO EACH DOOR INDICATED TO BE CONTROLLED WITH DOOR NUMBER/DESCRIPTION PROVIDED ON FACEPLATE. PROVIDE LABELS PER SPECIFICATION SECTION 260553.

PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTION 281300 INCLUDING, BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, AND CABLING. SUBMIT SHOP DRAWINGS FOR APPROVAL. INTEGRATE DOOR RELEASE WITH DOOR HARDWARE AND ACCESS CONTROL SYSTEM.

REFER TO ACCESS CONTROL AND ARCHITECTURAL DOOR HARDWARE SPECIFICATIONS FOR COORDINATION OF

FEATURES, DEVICES, AND CONNECTIONS REQUIRED.

INTRUSION DETECTION SYSTEM

- CONTROL PANEL

CIRCUIT CONTROL PANEL TO 20A 120V BRANCH CIRCUIT IN LOCAL UPS BRANCH PANEL OF THE ASSOCIATED CONSTRUCTION PHASE. REFER TO FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATIONS. COORDINATE CONNECTION REQUIREMENTS WITH FINAL EQUIPMENT SELECTION AND PROVIDED NEMA 5-20 RECEPTACLE OR HARD-WIRED CONNECTION TO CONTROL PANEL AS REQUIRED. PROVIDE ONE (1) NETWORK DATA CABLE FROM ASSOCIATED COMMUNICATIONS DISTRIBUTION ROOM. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTIONS 280513 AND 281300 INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, ROUGH-INS, AND CABLING. SUBMIT SHOP DRAWINGS FOR APPROVAL. COORDINATE EXACT LOCATION OF KEYPAD WITH ENGINEER, ARCHITECT, AND ARCHITECTURAL INTERIOR ELEVATIONS.

INTRUSION DETECTION SYSTEM

- KEYPAD

PROVIDE KEYPAD FOR INTRUSION DETECTION SYSTEM AT APPROXIMATE LOCATION INDICATED ON FLOOR PLANS, MOUNTED AT 48" AFF. COORDINATE CABLING AND ROUGH-IN REQUIREMENTS WITH MANUFACTURER. PROVIDE CABLING TO INTRUSION DETECTION SYSTEM CONTROL PANEL PER MANUFACTURER INSTALLATION REQUIREMENTS. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. PROVIDE CABLING PER SPECIFICATION SECTIONS 280513 AND 281300. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTIONS 280513 AND 281300 INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, ROUGH-INS, AND CABLING. SUBMIT SHOP DRAWINGS FOR APPROVAL. COORDINATE EXACT LOCATION OF KEYPAD WITH ENGINEER, ARCHITECT, AND

ARCHITECTURAL INTERIOR ELEVATIONS.

INTRUSION DETECTION SYSTEM

- MOTION SENSOR

PROVIDE MOTION SENSOR COVERAGE OF SPACE INDICATED FOR INTRUSION DETECTION SYSTEM. EXACT QUANTITIES AND LOCATIONS OF DEVICES SHALL BE DETERMINED BY MANUFACTURER REQUIREMENTS. MOUNT DEVICES IN ACCESSIBLE LOCATIONS. PROVIDE BACK BOX AND CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING FOR CABLING AT LOCATIONS INDICATED WITHIN GYP CEILINGS OR WHERE EXPOSED WITHIN UNFINISHED AREAS.

COORDINATE CABLING AND ROUGH-IN REQUIREMENTS WITH MANUFACTURER. PROVIDE CABLING TO INTRUSION DETECTION SYSTEM CONTROL PANEL PER MANUFACTURER INSTALLATION REQUIREMENTS. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS.

PROVIDE CABLING PER SPECIFICATION SECTIONS 280513 AND 281300. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTIONS 280513 AND 281300 INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, ROUGH-INS, AND CABLING. SUBMIT SHOP DRAWINGS FOR APPROVAL.

SECURITY SURVEILLANCE

CAMERA - CEILING

GENERAL;

PROVIDE POWER, ROUGH-INS, AND CABLING FOR POWER OVER ETHERNET (POE) SECURITY SURVEILLANCE CAMERA (AXIS M3067-P) AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH CAMERA TYPE AT LOCATIONS INDICATED. REFER TO FLOOR PLANS FOR CAMERA INSTALLATION LOCATION. SECURITY SURVEILLANCE COMPONENTS SHALL BE RATED FOR CONTINUOUS OPERATION IN THEIR INSTALLED PROJECT CONDITIONS AS REQUIRED IN SPECIFICATION SECTION 282300. PROVIDE ONE (1) CATEGORY 6A NETWORK DATA CABLE FROM ASSOCIATED COMMUNICATIONS DISTRIBUTION ROOM TO APPROXIMATE LOCATION INDICATED ON FLOOR PLANS, COILED ABOVE FINISHED CEILING WITH 10' OF SLACK. FOR CEILING TILE INSTALLATIONS, TERMINATE THE CEILING END WITH A RJ-45 FEMALE CONNECTOR MOUNTED IN A SURFACE MOUNT BLOCK. PROVIDE A 3' PATCH CABLE TO CONNECT THE CAMERA TO THE FEMALE RJ-45 CONNECTOR. INSTALL CAMERA CENTERED IN CEILING TILE. FOR LOCATIONS INDICATED WITHIN GYP CEILINGS, PROVIDE A BACK BOX WITH SINGLE GANG TRIM RING AND ONE (1) 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING FOR CABLING. IN UNFINISHED AREAS, PROVIDE SURFACE MOUNTED CONDUIT AND BACK BOX. COORDINATE ROUGH-IN REQUIREMENTS, PENDANT MOUNTS, PROTECTIVE DOMES, AND OTHER REQUIRED ACCESSORIES FOR EXTERIOR CAMERA LOCATIONS WITH SELECTED MANUFACTURER. PROVIDE 20A 120V NORMAL BRANCH CIRCUIT TO CAMERA LOCATIONS AS REQUIRED BY SELECTED MANUFACTURER FOR HEATED ENCLOSURES, PAN-TILT-ZOOM FUNCTIONS, AND ACCESSORIES.

COORDINATE CABLING, POWER, AND ROUGH-IN REQUIREMENTS WITH SELECTED MANUFACTURER FOR CAMERA LOCATIONS WITH NETWORK DATA CABLE LENGTHS EXCEEDING 100 METERS. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. PROVIDE NETWORK DATA CABLES AND JACKS PER SPECIFICATION SECTION 280513. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTION 282300 INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, AND CABLING. SUBMIT SHOP DRAWINGS FOR APPROVAL. COORDINATE EXACT

MOUNTING LOCATION WITH OWNER PRIOR TO INSTALLATION.

SECURITY SURVEILLANCE

CAMERA - WALL

PROVIDE POWER, ROUGH-INS, AND CABLING FOR POWER OVER ETHERNET (POE) SECURITY SURVEILLANCE CAMERA AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH CAMERA TYPE AT LOCATIONS INDICATED. REFER TO FLOOR PLANS FOR CAMERA INSTALLATION LOCATION. SECURITY SURVEILLANCE COMPONENTS SHALL BE RATED FOR CONTINUOUS OPERATION IN THEIR INSTALLED PROJECT CONDITIONS AS REQUIRED IN SPECIFICATION SECTION 282300. PROVIDE ONE (1) CATEGORY 6A NETWORK DATA CABLE FROM ASSOCIATED COMMUNICATIONS DISTRIBUTION ROOM TO APPROXIMATE LOCATION INDICATED ON FLOOR PLANS, COILED ABOVE FINISHED CEILING WITH 10' OF SLACK. PROVIDE 4" SQUARE BACK BOX, MOUNTED AT 84” AFF WITH SINGLE GANG TRIM RING AND ONE (1) 1" CONDUIT TO ABOVE FINISHED ACCESSIBLE CEILING IN UNFINISHED AREAS, PROVIDE SURFACE MOUNTED CONDUIT AND BACK BOX. COORDINATE ROUGH-IN REQUIREMENTS, PENDANT MOUNTS, PROTECTIVE DOMES, AND OTHER REQUIRED ACCESSORIES FOR EXTERIOR CAMERA LOCATIONS WITH SELECTED MANUFACTURER. PROVIDE 20A 120V NORMAL BRANCH CIRCUIT TO CAMERA LOCATIONS AS REQUIRED BY SELECTED MANUFACTURER FOR HEATED ENCLOSURES, PAN-TILT-ZOOM FUNCTIONS, AND ACCESSORIES. COORDINATE CABLING, POWER, AND ROUGH-IN REQUIREMENTS WITH SELECTED MANUFACTURER FOR CAMERA LOCATIONS WITH NETWORK DATA CABLE LENGTHS EXCEEDING 100 METERS.

CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. PROVIDE NETWORK DATA CABLES AND JACKS PER SPECIFICATION SECTION 280513. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTION 282300 INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, AND CABLING. SUBMIT SHOP DRAWINGS FOR APPROVAL.

COORDINATE EXACT MOUNTING LOCATION WITH OWNER PRIOR TO INSTALLATION.

DATA SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

COMMUNICATIONS OUTLET -

CEILING

PROVIDE ONE (1) CATEGORY 6A NETWORK DATA CABLE FROM ASSOCIATED COMMUNICATIONS DISTRIBUTION ROOM TO APPROXIMATE LOCATION INDICATED ON FLOOR PLANS. TERMINATE CABLE WITH RJ45 CONNECTOR IN FACEPLATE, CENTERED IN CEILING TILE. PROVIDE WITH 15' OF CABLE SLACK AT LOCATION INDICATED. PROVIDE ROUGH-IN PER COMMUNICATIONS OUTLET DETAIL AT LOCATIONS INDICATED WITHIN GYP CEILINGS. PROVIDE SURFACE MOUNTED CONDUIT AND BACK BOX IN UNFINISHED AREAS. CABLE SHALL BE ROUTED WITHIN CABLE

TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS.

COMMUNICATIONS OUTLET -

WALL

GENERAL:

PROVIDE COMMUNICATIONS OUTLET AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH OUTLET TYPE. REFER TO PLANS FOR OUTLET DESIGNATION AND QUANTITIES OF NETWORK VOICE/DATA CABLES TO BE PROVIDED TO OUTLET FROM ASSOCIATED NEAREST COMMUNICATIONS DISTRIBUTION ROOM. PROVIDE ROUGH-IN PER COMMUNICATIONS OUTLET DETAIL. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTION 271500 INCLUDING, BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, JACKS, INSERTS, FACEPLATES, AND CABLING. SUBMIT SHOP DRAWINGS FOR APPROVAL. COORDINATE EXACT FINAL LOCATION WITH ARCHITECTURAL INTERIOR ELEVATIONS PRIOR TO INSTALLATION. PROVIDE CABLING AS LISTED BELOW. OUTLETS WITH NO CABLING DESIGNATION SHALL BE EMPTY WITH A BLANK WALL PLATE.

CABLING DESIGNATIONS ARE TYPICAL FOR ALL WALL, FLOOR, AND CEILING COMMUNICATIONS DEVICES. REFER TO

SPECIFICATIONS FOR CABLING REQUIREMENTS FOR EACH TYPE.

-V = ONE (1) VOICE CABLE

-D = ONE (1) DATA CABLE

TYPE ‘W’, WALL PHONE:

PROVIDE ONE (1) NETWORK VOICE CABLE, MOUNTED IN WALL PHONE MOUNTING BRACKET FACEPLATE, MOUNTED AT 48” AFF. COORDINATE MOUNTING LOCATION WITH OTHER TRADES AND FINAL EQUIPMENT SELECTION.

WIRELESS ACCESS POINT -

CEILING

OWNER PROVIDED WIRELESS ACCESS POINT AT APPROXIMATE LOCATION INDICATED. PROVIDE TWO (2) CATEGORY 6A NETWORK DATA CABLE FROM ASSOCIATED COMMUNICATIONS DISTRIBUTION ROOM TO APPROXIMATE LOCATION INDICATED ON FLOOR PLANS, COILED ABOVE FINISHED CEILING. TERMINATE CABLE WITH RJ45 CONNECTOR WITH COMMSCOPE CEILING CONNECTOR ASSEMBLY (OR PRIOR APPROVED EQUIVALENT).

PROVIDE WITH 15' OF CABLE SLACK AT LOCATION INDICATED. PROVIDE ROUGH-IN PER COMMUNICATIONS OUTLET DETAIL AT LOCATIONS INDICATED WITHIN GYP CEILINGS. PROVIDE SURFACE MOUNTED CONDUIT AND BACK BOX IN UNFINISHED AREAS. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. LOCATIONS SHOWN ARE PRELIMINARY. CONFIRM FINAL LOCATION WITH

OWNER PRIOR TO PULLING CABLE.

COMMUNICATION SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

4 POST COMMUNICATIONS RACK PROVIDE 7'-0" TALL 45U, 4 POST TELECOMMUNICATIONS CHANNEL RACK AT APPROXIMATE LOCATIONS INDICATED ON FLOOR PLANS. PROVIDE MIGHTY MO 20 CABLE MANAGEMENT RACK 30" DEPTH, WHITE FINISH MODEL NUMBER:

OR-MM2073038-W (OR PRIOR APPROVED EQUIVALENT) WITH VERTICAL CABLE MANAGEMENT OR-MM20VMD706 (OR PRIOR APPROVED EQUIVALENT). REFER TO FLOOR PLANS FOR DATA SWITCH ELECTRICAL SOURCE AND REQUIREMENTS. PROVIDE TELECOMMUNICATIONS RACK AND ALL ACCESSORIES PER SPECIFICATION SECTION 271100. PROVIDE ALL ACCESSORIES FOR A COMPLETE INSTALLATION, INCLUDING BUT NOT LIMITED TO: BRACKETS, MOUNTING FRAMES, HORIZONTAL AND VERTICAL WIRE MANAGEMENT, AND GROUNDING CONNECTIONS.

PROVIDE WITH RACK MOUNTED PDU:

APC AP8861 RPDU (OR PRIOR APPROVED EQUIVALENT); RACK PDU 2G, METERED; L21-20 PLUG; THREE PHASE;

120/208V INPUT; 20A; ZERO U, 5.7 KW, 208V, (36) C13 & (6) C19 & (2) 5-20 OUTLETS; A-SIDE BLACK, B-SIDE WHITE OR

OTHER DISTINCTIVE COLOR.

WHERE INDICATED ON PLANS PROVIDE:

EATON BLADE UPS ZC0517700110000 (OR PRIOR APPROVED EQUIVALENT), RACK-MOUNTED 5 KW, 6RU, 19" RACK-MOUNTABLE, 208V UNINTERRUPTIBLE POWER SUPPLY (UPS) WITH NEMA 20A L21-20P INPUT AND L21-20R

OUTPUT.

REFER TO VA OIT "INFRASTRUCTURE STANDARD FOR TELECOMMUNICATIONS SPACES VERSION 3.1" FOR ALL COMPONENT REQUIREMENTS. COORDINATE EXACT FINAL LOCATION WITH OWNER'S IT REPRESENTATIVE PRIOR TO INSTALLATION. PROVIDE ALL POWER CONNECTIONS INDICATED ON FLOOR PLANS AT FINAL RACK LOCATION. REFER

TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

COMMUNICATIONS CABINET PROVIDE 7'-0" TALL 45U, TELECOMMUNICATIONS CABINET AT APPROXIMATE LOCATIONS INDICATED ON FLOOR PLANS. REFER TO FLOOR PLANS FOR DATA SWITCH ELECTRICAL SOURCE AND REQUIREMENTS. PROVIDE TELECOMMUNICATIONS CABINET AND ALL ACCESSORIES PER SPECIFICATION SECTION 271100. PROVIDE ALL ACCESSORIES FOR A COMPLETE INSTALLATION, INCLUDING BUT NOT LIMITED TO: BRACKETS, MOUNTING FRAMES, HORIZONTAL AND VERTICAL INTEGRATED WIRE MANAGEMENT, LASHING MANAGER, RADIUS DROPS, PDU

BRACKETS, AND GROUNDING CONNECTIONS.

TYPE: SERVER CABINET WITH VERTICAL EXHAUST DUCT

PROVIDE TERAFRAME F-SERIES GEN 3 CABINET FF1N-111C-E52-B (OR PRIOR APPROVED EQUIVALENT). PROVIDE

WITH ALL ACCESSORIES AS DEFINED IN OIT STANDARDS.

TYPE: NETWORK CABINET WITH VERTICAL EXHAUST DUCT

PROVIDE CHATSWORTH NF8N-115N-E52-1 (OR PRIOR APPROVED EQUIVALENT). PROVIDE WITH SIDE PANELS WITH BRUSH SEALED CABLE OPENINGS CHATSWORTH 39043-E63 (OR PRIOR APPROVED EQUIVALENT) ORDERED SEPERATELY FROM CABINET. PROVIDE WITH ALL ACCESSORIES AS DEFINED IN OIT STANDARDS.

REFER TO VA OIT "INFRASTRUCTURE STANDARD FOR TELECOMMUNICATIONS SPACES VERSION 3.0" FOR ALL COMPONENT REQUIREMENTS. COORDINATE EXACT FINAL LOCATION WITH OWNER'S IT REPRESENTATIVE PRIOR TO INSTALLATION. PROVIDE ALL POWER CONNECTIONS INDICATED ON FLOOR PLANS AT FINAL CABINET LOCATION.

REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

COMMUNICATIONS FIRE RATED

PATHWAY - FLOOR

PROVIDE STI FIRESTOP EZ-PATH COMMUNICATIONS FIRE RATED PATHWAY THROUGH FLOOR AT LOCATIONS INDICATED ON FLOORPLANS. COORDINATE MOUNTING LOCATION WITH STRUCTURE, EQUIPMENT WITHIN ROOM, ACCESS TO EQUIPMENT, WALLS BELOW ROOM, AND OTHER TRADES. INSTALL PER MANUFACTURERS RECOMMENDATIONS. REFER TO FLOOR PLANS FOR PATHWAY TYPE AND QUANTITIES. PROVIDE PATHWAY TYPES AS

INDICATED BELOW.

(F1) - FULL KIT CATALOG # EZDP144FKS2 (1-4"x4" PATHWAY) (F2) - FULL KIT CATALOG # EZDG444S2 (4-4"x4" PATHWAYS) (F3) - FLOOR GRID CATALOG # EZG844 AND ONE (1) PATHWAY MODULE CATALOG # EZD444MBS2 (4-4"x4" PATHWAYS & 4-4"x4" SPACES) (F4) - FULL KIT CATALOG # EZDG844S2 (8-4"x4" PATHWAYS)

COMMUNICATIONS FIRE RATED

PATHWAY – WALL

PROVIDE STI FIRESTOP EZ-PATH COMMUNICATIONS FIRE RATED PATHWAY AT LOCATIONS INDICATED ON FLOORPLANS. MOUNT PATHWAYS ABOVE ACCESSIBLE CEILING SPACES. COORDINATE MOUNTING HEIGHT WITH CABLE TRAY, TELECOMMUNICATION RACK HEIGHTS, CEILING, AND OTHER TRADES. INSTALL PER MANUFACTURERS RECOMMENDATIONS. COORDINATE REQUIRED WALL OPENING WITH STUD SPACING. REFER TO FLOOR PLANS FOR

PATHWAY TYPE AND QUANTITIES. PROVIDE PATHWAY TYPES AS INDICATED BELOW.

(A1) - FULL KIT CATALOG # EZDP133CWK (1-3"x3" PATHWAY) (A2) - FULL KIT CATALOG # EZDP233GK (2-3"x3" PATHWAYS) (A3) - FULL KIT CATALOG # EZDP333GK (3-3"x3" PATHWAYS) (A4) - FULL KIT CATALOG # EZDP433GK (4-3"x3" PATHWAYS) (A7) - FULL KIT CATALOG # EZDP733GK (7-3"x3" PATHWAYS) (A8) - TWO (2) FULL KIT CATALOG # EZDP433GK (8-3"x3" PATHWAYS) (STACKED) (B1) - FULL KIT CATALOG # EZD22 (1-2"x2" PATHWAY) (C1) - FULL KIT CATALOG # EZDP44S2 (1-4"x4" PATHWAY) (C2) - TWO (2) MODULE CATALOG # EZD44S2 & ONE (1) EZP544W (2-4"x4" PATHWAYS) (C3) - THREE (3) CATALOG # EZD44S2 & ONE (1) EZP544W (3-4"x4" PATHWAYS) (C4) - FOUR (4) CATALOG # EZD44S2 & ONE (1) EZP544W (4-4"x4" PATHWAYS) (REQUIRES 16" STUD SPACING) (C5) - FIVE (5) CATALOG # EZD44S2 & ONE (1) EZP544W (5-4"x4" PATHWAYS) (REQUIRES 24" STUD SPACING)

PROVIDE STI FIRESTOP EZ-PATH CABLE SPILLWAY AT LOCATIONS INDICATED ON FLOORPLANS WITH SUBSCRIPT 'S'.

PROVIDE ONE (1) SPILLWAY PER SLEEVE. REFER TO FLOORPLANS FOR SPILLWAY TYPE AND QUANTITIES.

(A#S) - CATALOG NO. RCM33

(C#S) - CATALOG NO. EZRCM44S

PROVIDE STI FIRESTOP EZ-PATH EXTENSION MODULES AT LOCATIONS INDICATED ON PLANS WITH SUBSCRIPT 'E'.

PROVIDE ONE (1) EXTENSION MODULE PER SLEEVE. WHERE PATHWAY IS INDICATED WITH SUBSCRIPT 'EE', PROVIDE ONE (1) EXTENSION MODULES ON EACH END. REFER TO FLOORPLANS FOR EXTENSION MODULE TYPE AND

QUANTITIES.

(A#E) - CATALOG NO. EZD33E

(C#E) - CATALOG NO. EZD44ES

PLYWOOD BACKBOARD PROVIDE 3/4" THICK X 4' WIDE X 8' HIGH A/C GRADE FIRE-RETARDANT TREATED PLYWOOD BACKBOARD AT APPROXIMATE LOCATION INDICATED. REFER TO FLOORPLANS FOR WIDTHS. CUT ADDITIONAL PLYWOOD TO FIT APPROXIMATE WIDTH INDICATED ON FLOORPLANS. MOUNT PLYWOOD VERTICALLY. BUTT ADJACENT SHEETS TIGHTLY, AND FORM SMOOTH GAP-FREE CORNERS AND JOINTS. PROVIDE WITH TWO (2) COATS OF WHITE PAINT ON ALL FACES AND EDGES. PROVIDE WITH LABEL ON EACH SHEET OF PLYWOOD WITH FIRE RATINGS, VISIBLE

AFTER PAINTING. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

TELECOMMUNICATIONS

GROUND BAR

PROVIDE LENGTH AS REQUIRED TO ACCOMMODATE TERMINATIONS, MINIMUM 10" IN LENGTH. REFER TO

SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

WALL MOUNT COMMUNICATIONS

RACK

PROVIDE 48" TALL 26U WALL MOUNT TELECOMMUNICATIONS CABINET AT APPROXIMATE LOCATIONS INDICATED ON FLOOR PLANS. PROVIDE CUBE-IT WALL-MOUNT CABINET; GEN 3; 26U; #12-24 TAPPED RAILS; TEMPERED GLASS DOOR; GLACIER WHITE (OR PRIOR APPROVED EQUIVALENT). PROVIDE TWO (2) RACK MOUNTED POWER STRIPS WITH L5-20 INPUT AND 5-15 OUTPUT, 1RU AT EACH RACK; CHATSWORTH 12820-708 (OR PRIOR APPROVED EQUIVALENT). REFER TO FLOOR PLANS FOR DATA SWITCH ELECTRICAL SOURCE AND REQUIREMENTS. PROVIDE TELECOMMUNICATIONS RACK AND ALL ACCESSORIES PER SPECIFICATION SECTION 271200. PROVIDE ALL ACCESSORIES FOR A COMPLETE INSTALLATION, INCLUDING BUT NOT LIMITED TO: PLYWOOD BACKING, BRACKETS, MOUNTING FRAMES, HORIZONTAL AND VERTICAL WIRE MANAGEMENT, BRUSH KIT, FAN KIT, FRONT AND REAR RAIL

KIT, FAN FILTER KIT, SHELF (TWO PER CABINET), AND GROUNDING CONNECTIONS.

PROVIDE WITH CABINET MOUNTED UPS:

EATON UPS (OR PRIOR APPROVED EQUIVALENT), 3 KW, 2RU, 19" RACK-MOUNTABLE, 208V UNINTERRUPTIBLE POWER

SUPPLY (UPS) WITH NEMA 20A L5-20P INPUT AND L5-20R OUTPUT.

REFER TO VA OIT "OIT DESIGN GUIDE FOR NATIONAL CEMETERY INSIDE PLANT TELECOMMUNICATIONS WALL-MOUNTED CABINET" FOR ALL COMPONENT REQUIREMENTS. COORDINATE EXACT FINAL LOCATION WITH OWNER'S IT REPRESENTATIVE PRIOR TO INSTALLATION. PROVIDE ALL POWER CONNECTIONS INDICATED ON FLOOR PLANS AT FINAL RACK LOCATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

DATA SYMBOLS

PLAN SYMBOL NAME

FLOOR BOX - VOICE/DATA

ELECTRICAL EQUIPMENT SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

DIRECT DIGITAL CONTROL

SYSTEM CONTROL PANEL

CIRCUIT CONTROL PANEL TO 20A 120V BRANCH CIRCUIT IN LOCAL BRANCH PANEL (GENERATOR FEED WHEN BUILDING HAS GENERATOR BACKUP). REFER TO FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATIONS.

COORDINATE CONNECTION REQUIREMENTS WITH FINAL EQUIPMENT SELECTION AND PROVIDED NEMA 5-20 RECEPTACLE OR HARD-WIRED CONNECTION TO CABINET AS REQUIRED. PROVIDE ONE (1) NETWORK DATA CABLE

FROM ASSOCIATED COMMUNICATIONS DISTRIBUTION ROOM.

Revisions: Date:

S

S

BLD 2S TY BRI CK

BL D1 GR EE N HS E

851. 33

851. 69

535 0

611 8

GR I N DE R MOTOR

848. 69 262 7

PM

FP OL EFP OL E

839. 49

843. 36920. 67

249 2

503 3246 6

P

P

P

841. 70

844. 42

843. 68

210 6

267 2

563 6

UP GU Y

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

858. 03

839. 49

841. 46

843. 42

843. 22

844. 17

841. 77

849. 77

848. 95

848. 68

845. 91

850. 91

844. 09

843. 72

848. 19

846. 73

849. 28

208 3

234 2

234 3

234 4

234 6

234 7

234 8

261 9

262 0 262 1

262 2

285 6

507 8 513 1

513 2

516 6 516 7

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON EPH ON E

PH ON E M A RK E RPH ON E

MH TE L FO

PH ON EPH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

MH TE L

MH TE L

MH TE L

844. 84

845. 51

845. 86

845. 17

843. 89

844. 45

842. 46

841. 03

841. 38841. 11

838. 28838. 17

841. 02

843. 31843. 16

845. 31

842. 38

841. 61

846. 88

846. 60

847. 95

846. 41

846. 51

847. 28

839. 32

846. 03

841. 88

201 2

202 2 202 3

213 3

213 4

213 8

217 0 219 2

233 0233 1

233 7233 8

253 1

261 4 261 5

261 6

261 7

261 8

262 4

262 5

265 5

269 7

269 8

285 7

302 7

317 0

337 4

PT

PT

PT

PT

PT

PT

PT

PT

PT PT

PT PT

T

PT

PT

PT

PT

PT

PT

PT

PT

PT

PT

PT

T

T

T

G

G

G

G

G

G G

G

G

G

G

G

G

G

G

G

847. 28

846. 66

846. 84

846. 48

844. 92

841. 18

840. 65

840. 61

841. 06

839. 43

837. 26

836. 86

839. 65

843. 22

840. 49

831. 07

200 0

200 2

200 3

200 4

209 2

210 9 211 0

211 1

211 3

211 6

235 5

235 6

235 8

264 4

324 1

512 9

RR T

RR T1

RR T2

RR T3

RR T3

RR T2

RR T1

RR T

RR T

RR T1RR T2

RR T3

RRT3 ERRT 1

RR TRRT2 E

823. 54

823. 53

823. 42

823. 41

823. 33

823. 28

823. 44

823. 46

823. 30

823. 27823. 28

823. 25

823. 23823. 22

823. 22823. 23

150151

153154 155156

FL B

FL

FL

FL

FL

824. 46

824. 20

824. 89

824. 91

826. 99

FP

839. 17

BP

BP

38TH STREET

L

IN

C O

L N

B O

U L E

V A

R D

T H

E C

H

IC

A G

O , S

A

IN

T

LO

U

IS

A N

D P

IT

T S B U

R G

R A

IL

R O

A D

M

IS

S

IS

S

IN

E W

A R

IV

ER

HOME AVENUE

STEEL CIRCLE DRIVE

VINE RO

AD

G R

A Y

R O

A D

DOCTORS ROAD

VIN

E R

O

AD

B L A

C K

R O

A D

C O

T T

A G

E A

V E

N U

E

B L A

C K

R O

A D

C O

T T

A G

E A

V E

N U

E

NELSON AVENUE

ORCHARD AVENUE

WATER STREET

BLAC

K R

O

AD

M C

M A

H O

N A

V N

E U

E

BLACK ROAD

BLACK R

OAD

WATER STREET

RAILROAD AVENUE

M E

C H

A N

I C S

A V

E N

U E

CHAPMAN AVENUE

IN

D

IA

N

A A

V E

N U

E

S T

E E

L C

IR

C L E

D R

IV

E

O R

C H

A R

D A

V E

N U

E

S H

O R

T S

T R

E E

T

G R

A Y

R O

A D

G R

A Y

R O

A D

M C

M A

H O

N A

V E

N U

E

WATER STREET

6"

6"

6" VC P

10" VCP

10 " VCP

36" R C

P

6" PVC

6" VCP

PER RECORD

4 " R

C P

" R C

P

" V

C P

6" P

VC

8" V

C P

10" V C

P

4" R

C P

8" P

VC

12"

0" P

V C

8" V C

P

8" VCP

" V C

P

4"

12 " VCP

24 " VCP

24" V

CP

" V C

P

1 8

6" PVC

P

V C

P

V C

P

V C

P

V C

12" 15" 15" 15"

24" RCP

R C

P

" R C

P

" PV

C

8" PVC

12" PVC

21" RCP

" VC

P

" VC

P

10"

12" P

VC

8" PVC

V C

P

10" VCP

12" PVC

P

V C

15"

12"

10"

8"

15" PVC

15" PVC

24 " VCP

12"

12" VCP

24" VCP

8" VCP

10" VCP

V

C P

" V

C P

10"

10"

6" V

CP

8" V

C P

8" CPP

6" STEEL

6"

6"

10 "

1 0

P V

C

10" PVC

" P

V C

6" PVC

" P

V C

P V

C

12" PV

C

" P V

C

8 " R

C P

12 " C

PP

6" PVC

" P

V C

12" CPP

6"

10"

10"

6"

2 "

15" PVC

12"

4"

R C

P

1 2 " P

V C

12" PVC

12" PV

C

" PV

C

" R C

P

V C

P

P V

C

15" RCP 15" RCP

5 "

P V

C

P

V C

8" VCP

8 "

6" VCP

" V

C P

8" V C

P

" PV

C

3 0"

30" VCP

30" VCP

12" CPP

6 " V C

P

6" VCP

6" VCP

8" VCP

10" VCP

V C

P

" V

C P

0"

P V

C

18" VCP

10" V

CP

12" R

CP

12" R

CP

29 30 31

T516

153 156

T504

HA-4

S

12"

6" VCP

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

W SW S

W F

W F

PM

BLD 2S TY BRI CK

BL D1 GR EE N HS E

851. 33

851. 69

535 0

611 8

GR I N DE R MOTOR

848. 69 262 7

PM

FP OL EFP OL E

839. 49

843. 36920. 67

249 2

503 3246 6

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON EPH ON E

PH ON E M A RK E RPH ON E

MH TE L FO

PH ON EPH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

PH ON E

MH TE L

MH TE L

MH TE L

844. 84

845. 51

845. 86

845. 17

843. 89

844. 45

842. 46

841. 03

841. 38841. 11

838. 28838. 17

841. 02

843. 31843. 16

845. 31

842. 38

841. 61

846. 88

846. 60

847. 95

846. 41

846. 51

847. 28

839. 32

846. 03

841. 88

201 2

202 2 202 3

213 3

213 4

213 8

217 0 219 2

233 0233 1

233 7233 8

253 1

261 4 261 5

261 6

261 7

261 8

262 4

262 5

265 5

269 7

269 8

285 7

302 7

317 0

337 4

PT

PT

PT

PT

PT

PT

PT

PT

PT PT

PT PT

T

PT

PT

PT

PT

PT

PT

PT

PT

PT

PT

PT

T

T

T

R R T

RR T1

RR T2

RR T3

RR T3

RR T2

RR T1

R R T

R R T

RR T1RR T2

RR T3

RRT3 ERRT 1

R R TRRT2 E

823. 54

823. 53

823. 42

823. 41

823. 33

823. 28

823. 44

823. 46

823. 30

823. 27823. 28

823. 25

823. 23823. 22

823. 22823. 23

150151

153154 155156

FL B

FL

FL

FL

FL

824. 46

824. 20

824. 89

824. 91

826. 99

FP

839. 17

BP

BP

38TH STREET

L

IN

C O

L N

B O

U L E

V A

R D

T H

E C

H

IC

A G

O , S

A

IN

T

LO

U

IS

A N

D P

IT

T S B U

R G

R A

IL

R O

A D

M

IS

S

IS

S

IN

E W

A R

IV

ER

HOME AVENUE

STEEL CIRCLE DRIVE

VINE RO

AD

G R

A Y

R O

A D

DOCTORS ROAD

VIN

E R

O

AD

B L A

C K

R O

A D

C O

T T

A G

E A

V E

N U

E

B L A

C K

R O

A D

C O

T T

A G

E A

V E

N U

E

NELSON AVENUE

ORCHARD AVENUE

WATER STREET

BLAC

K R

O

AD

M C

M A

H O

N A

V N

E U

E

BLACK ROAD

BLACK R

OAD

WATER STREET

RAILROAD AVENUE

M E

C H

A N

I C S

A V

E N

U E

CHAPMAN AVENUE

IN

D

IA

N

A A

V E

N U

E

S T

E E

L C

IR

C L E

D R

IV

E

O R

C H

A R

D A

V E

N U

E

S H

O R

T S

T R

E E

T

G R

A Y

R O

A D

G R

A Y

R O

A D

M C

M A

H O

N A

V E

N U

E

WATER STREET

29 30 31

T516

153 156

T504

HA-4

S

12"

6" VCP

U

U

U

U

U

U U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

W SW S

W F

W F

PM

NEW 4" SERVICE

ENTRANCE CONDUIT

NEW SERVICE ENTRANCE ROOM

B005 LOCATED WITHIN BASEMENT

LEVEL OF BUILDING 172

TOTAL SERVICE PROVIDER FIBER

LENGTH FROM PROPERTY LINE

TO NEW SERVICE DEMARC IS

APPROXIMATELY 1300'.

EXISTING SERVICE ENTRANCE

ROOM LOCATED WITHIN FIRST

FLOOR OF BUILDING 127

SIDE B

CABLING

ROUTING

(TYP)

SERVER

ROOM

DASHED LINES SHOWN ON PLANS ARE APPROXIMATE

LOCATION OF EXISTING PATHWAYS TO BE USED FOR

ROUTING OF FIBER SIDE A AFTER INSTALLATION OF SIDE B

AND REMOVAL OF EXISTING. EXISTING PATHWAYS ARE

NOTED FROM FIELD VERIFICATION AND EXISTING PLANS.

CONTRACTOR IS RESPONSIBLE FOR FIELD INVESTIGATION

OF EXACT ROUTING OF EXISTING PATHWAYS TO BE REUSED.

(TYP)

SIDE A

CABLING

ROUTING

(TYP)

NEW DUCTBANK -

REFER TO CIVIL

PLANS

T506

C1

T506

C1

T506

C1

T506

C1

T506

C1

T506

C1

T506

C1

T506

C1

T506

F1

T506

F1

T506

F1 T506

C1

T506

C1

T506

F1

T506

F1

T506

F1

T506

C1

T506

C1

KEY PLAN

MAIN

ENTRY

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 04/15/2022

Sheet of

B

IM

/2

V A

M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.C A

M P

U S

M

A R

IO

N

R

.r v t

/1

/2

:3

:5

A

M

T100

SITE PLAN -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

JLK SSK

16181

2 313

SHEET NOTES:

1. THE CONTRACTOR SHALL INCLUDE WITHIN THEIR BID, ALL WORK BEING PROVIDED BY THE

TELECOMMUNICATIONS UTILITY PROVIDER, AT&T. COSTS ASSOCIATED WITH THE NEW

TELECOMMUNICATIONS SERVICE SHALL BE INCLUDED WITHIN THE BASE BID AND SHALL NOT BE AN ADDITIONAL COST TO THE PROJECT AFTER THE BID PHASE. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT AT&T, COORDINATE SCOPE OF WORK, DIVISION OF LABOR, AND RECEIVE A PRICE. THE CONTRACTOR SHALL INCLUDE ALL SCOPE ASSOCIATED WITH THE NEW SERVICE INCLUDING BUT NOT LIMITED TO EXCAVATION, SHORING, NEW CONDUIT AS INDICATED ON PLANS, BACKFILL, AND FINISH TO MATCH EXISTING CONDITIONS. CONTRACTOR SHALL RECEIVE THE WORK REQUEST FORM FROM THE VA, SUBMIT THE SERVICE REQUEST TO AT&T, AND INCORPORATE ENGINEERING FEES AND PHYSICAL WORK

PERFORMED IN THE CONTRACTORS BID.

2. PROVIDE JUNCTION BOX WITHIN BUILDING 3 CENTER OF BUILDING TO ALLOW FOR NEW FIBER TO BE PULLED INTO A NEW TR IN BUILDING 3 IN THE FUTURE. SIZE JUNCTION BOX SIMILAR TO OTHER BUILDINGS OF SIMILAR

SHAPE AND SIZE.

1" = 160'-0" F2

SITE PLAN - TELECOMMUNICATIONS

GENERAL NOTES:

A. EXTERIOR DUCTBANK WILL BE PROVIDED BY VA CONTRACTOR. LOCAL SERVICE PROVIDER TO PULL

SERVICE FIBER THROUGH PROVIDED PATHWAY INTO BUILDING 172. SERVICE ENTRANCE CONDUIT WILL BE PROVIDED WITHIN BUILDING 172 FROM ENTRANCE LOCATION INTO BUILDING TO NEW ENTRANCE FACILITY

DEMARC ROOM. PULL BOXES WILL BE INCLUDED WITHIN PATHWAYS TO ALLOW FOR EASE OF

INSTALLATION.

B. REFER TO CIVIL PLANS FOR CONCRETE ENCASED CONDUIT DUCTBANK DESIGN. CONDUIT QUANTITIES WITHIN EACH SEGMENT OF DUCTBANK ARE INDICATED ON SHEETS CU-201 THROUGH CU-212. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF SCOPE OF WORK ASSOCIATED WITH SCOPE SHOWN ON CIVIL

PLANS WITH OTHER CONTRACTORS PRIOR TO BID TO ENSURE ALL SCOPE HAS BEEN CAPTURED.

DELINEATION OF DUCTBANK DESIGN SHOWN ON CIVIL PLANS AND PATHWAYS SHOWN ON

TELECOMMUNICATIONS SHEETS IS AT A PULLBOX LOCATED ADJACENT TO EACH BUILDING. REFER TO TELECOMMUNICATIONS DETAILS ON SHEET T505 FOR SCOPE FROM PULLBOXES INTO THE RESPECTIVE

BUILDINGS.

SIDE A

SIDE B

EXISTING PATHWAYS

NEW DUCTBANK

LINE TYPE KEY

(9) 4" C. FEEDING OUT-BUILDINGS (4) 4" C. FEEDING OUT-BUILDINGS

(1) 4" C. FOR SERVICE PROVIDER

(13) 4" C. FEEDING OUT-BUILDINGS

(SIDE B)

KEY PLAN

MAIN

ENTRY

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S.…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .