Atch 17 - MECH 3 of 7 - DRAWINGS.pdf

PDF 17 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction - Marion Federal contract opportunity
Solicitation number
36C77622B0040
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This federal contract opportunity solicitation involves infrastructure upgrades and renovations at the Marion VA Medical Center. The solicitation seeks contractors to perform electrical, HVAC, communication, physical security, and fiber infrastructure upgrades across multiple buildings on campus. Additional requirements include modifying impacted roads, walks, grading, drainage and other utilities. Data center WAN updates and hazardous material abatement are also within the scope of work. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction - Marion, newest first.
File Type Posted
Clarifications - Marion.pdf PDF
Atch 27 - Construction Wage Rates - Grant 8-19-22.pdf PDF
36C77622B0040 0005.pdf PDF
36C77622B0040 0004.pdf PDF
Atch 27 - Construction Wage Rates - Grant 8-12-22.pdf PDF
03 30 00 - Cast-In-Place Concrete.pdf PDF
Technical Questions - FINAL - Marion 8-11-22.pdf PDF
36C77622B0040 0003.pdf PDF
Atch 27 - Construction Wage Rates - Grant 7-15-22.pdf PDF
36C77622B0040 0002.pdf PDF
Atch 27 - Construction Wage Rates - Grant 7-8-22.pdf PDF
Site Visit Sign-in Sheet - Marion 7-11-22.pdf PDF
36C77622B0040 0001.pdf PDF
36C77622B0040 - 6-27-22.pdf PDF
Atch 3 - ARCH 1of 4 - DRAWINGS.pdf PDF
Atch 8 - CIVIL 2 of 2 - DRAWINGS.pdf PDF
Atch 26 - Limitations on Subcontracting - Construction.docx DOCX document
Atch 21 - MECH 7 of 7 - DRAWINGS.pdf PDF
Atch 7 - CIVIL 1 of 2 - DRAWINGS.pdf PDF
Atch 11 - ELEC 3 of 3 - DRAWINGS.pdf PDF
Atch 13 - HAZARDOUS ASBESTOS - DRAWINGS.pdf PDF
Atch 14 - HAZARDOUS LEAD BASED PAINT - DRAWINGS.pdf PDF
Atch 22 - STRUCTURAL - DRAWINGS.pdf PDF
Atch 24 - TELECOM 2 of 2 - DRAWINGS.pdf PDF
Atch 25 - COVID-19 Safety Protocols 12-14-21.pdf PDF
Atch 15 - MECH 1 of 7 - DRAWINGS.pdf PDF
Atch 2 - DRAWINGS SHEET INDEX.pdf PDF
Atch 6 - ARCH 4 of 4 - DRAWINGS.pdf PDF
Atch 18 - MECH 4 of 7 - DRAWINGS.pdf PDF
Atch 19 - MECH 5 of 7 - DRAWINGS.pdf PDF
Atch 28 - Contractor Safety - Environmental Form.docx DOCX document
Atch 29 - Site Visit Instructions.pdf PDF
Atch 1 - SPECIFICATIONS.pdf PDF
Atch 4 - ARCH 2 of 4 - DRAWINGS.pdf PDF
Atch 5 - ARCH 3 of 4 - DRAWINGS.pdf PDF
Atch 9 - ELEC 1 of 3 - DRAWINGS.pdf PDF
Atch 10 - ELEC 2 of 3 - DRAWINGS.pdf PDF
Atch 12 - GENERAL - DRAWINGS.pdf PDF
Atch 16 - MECH 2 of 7 - DRAWINGS.pdf PDF
Atch 20 - MECH 6 of 7 - DRAWINGS.pdf PDF
Atch 23 - TELECOM 1 of 2 - DRAWINGS.pdf PDF
Atch 27 - Construction Wage Rates - Grant 6-10-22.pdf PDF
Show all 42

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REMARKS:

1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.

2. PROVIDE THE FOLLOWING ACCESSORIES: MANUFACTURER'S DISCONNECT AND LINESET.

3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT

BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR

PRIOR TO ORDERING EQUIPMENT.

REMARKS:

1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.

2. PROVIDE CONCRETE PAD AND ANCHOR EXTERIOR UNIT TO PAD.

3. PROVIDE CURB RAILS AND ROOF SUPPORTS FOR OUTDOOR UNIT.

4. PROVIDE THE FOLLOWING ACCESSORIES: SINGLE POINT POWER CONNECTION, DISCONNECT, HAIL GUARDS, LOW AMBIENT KIT, WIND BAFFLES.

5. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT

BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR

PRIOR TO ORDERING EQUIPMENT.

REMARKS:

1. COORDINATE EXACT MODEL AND FRAME WITH CEILING / WALL TYPE.

2. WHEN INSTALLED IN A WALL, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES

ARE HORIZONTAL (PARALLEL TO THE FLOOR). WHEN INSTALLED IN A CEILING, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE PARALLEL TO THE LONG DIMENSION OF THE

GRILLE.

REMARKS:

1. PROVIDE DISCONNECT.

2. PROVIDE VIBRATION ISOLATION.

3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT BASED ON

PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC.

RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING

EQUIPMENT.

REMARKS:

1. PROVIDE MAGNAHELIC GAUGE ACROSS HOUSING FILTER.

2. PROVIDE FILTER BANK HOLDING FRAME. SUPPORT FRAME FROM STRUCTURE.

REMARKS:

1. PROVIDE WITH INTEGRAL CONDENSATE COOLER, BLOWER PACK.

REMARKS:

1. PERFORMANCE BASED ON FLUID AND CONDITIONS INDICATED IN THIS SCHEDULE.

2. PROVIDE WITH HIGH WATER LEVEL (OVERFLOW DETECTION) SWITCH WITH TERMINAL FOR CONNECTION TO DDC

EXTERNAL ALARM.

3. PROVIDE WITH BRASS CHECK VALVE.

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459

NON-SPRINKLERED

Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

-5

.T

R

.r v t

/1

/2

:2

:2

P

M

B51-52-M600

MECHANICAL SCHEDULES EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B51-52

04/15/2022 JMM GTS

16181

51 176

SPLIT SYSTEM AIR CONDITIONER - INDOOR SCHEDULE

MARK

ROOM SERVED

NOMINAL

CAPACITY

[TONS]

TOTAL COOLING

CAPACITY

[MBH]

CONDENSATE DRAIN

SIZE

INDOOR UNIT ELECTRICAL DATA

MANUFACTURER REMARKSNAME NUMBER

DIMENSIONS [IN] EAT

(DB / WB)

[°F] MODEL FLA VOLTAGE PHASE MCA DISCONNECT BY SCCRLENGTH WIDTH HEIGHT

SSIU-51-001JA TR 001J 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-51-001JB TR 001J 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SPLIT SYSTEM AIR CONDITIONER - OUTDOOR SCHEDULE

MARK

ROOM SERVED

NOMINAL

CAPACITY

[TONS]

TOTAL COOLING

CAPACITY

[MBH]

OUTDOOR UNIT ELECTRICAL DATA

MANUFACTURER REMARKSNAME NUMBER

DIMENSIONS [IN] SUMMER AMBIENT

AIR

[°F]

WINTER AMBIENT

AIR

[°F]

OPERATING

WEIGHT

[LBS] MODEL FLA VOLTAGE PHASE MCA MOCP DISCONNECT BY SCCRLENGTH WIDTH HEIGHT

SSOU-51-001JA TR 001J 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-51-001JB TR 001J 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

DIFFUSER, REGISTER, AND GRILLE SCHEDULE

MARK IMAGE DESCRIPTION MAX S.P. MATERIAL FINISH

FACE SIZE

NECK SIZE AIRFLOW MANUFACTURER MODEL REMARKSLENGTH WIDTH

G6 SINGLE DEFLECTION

RETURN GRILLE

0.10 in-wg STEEL PAINT, WHITE 6" 6" SEE PLAN SEE PLAN TITUS 350RL/SL (1)(2)

FAN SCHEDULE

MARK TYPE

MAX WEIGHT

[LBS]

AIRFLOW

[CFM]

TOTAL S.P.

[IN W.C.] MAX FAN RPM MAX FAN BHP

ELECTRICAL DATA

MANUFACTURER MODEL REMARKSFLA VOLTAGE PHASE DISCONNECT BY

F-1 IN-LINE 24 100 0.54 1288 0.03 1.5 115 V 1 MECHANICAL GREENHECK CSP-A390-VG (1)(2)(3)

FILTER SCHEDULE

MARK ASSOCIATED EQUIPMENT TYPE

DEPTH

[IN] MERV RATING REMARKS

PF-1 F-1 12"x12" 2" 11 (1)(2)

ELECTRODE STEAM HUMIDIFIER SCHEDULE

MARK SERVICE

MAKE UP WATER

CONNECTION SIZE

STEAM TO STEAM ELECTRIC ELECTRICAL DATA

MANUFACTURER MODEL REMARKS

CAPACITY

[LB / HR]

DRAIN PIPE CONNECTION

SIZE KW VOLTAGE PHASE

H-1 TR 001J 1/2" 5.6 3/4" 1.9 120 V 1 DRISTEEM XTR (1)

PUMP SCHEDULE

MARK

FLOW

[GPH]

TOTAL HEAD

[FT]

SHUT-OFF HEAD

[FT]

SUCTION /

DISCHARGE SIZE

[IN]

ELECTRICAL DATA

MANUFACTURER MODEL REMARKSHP FLA VOLTAGE

CP-1 200 20 32 3/8" 0.125 1.4 115 V LITTLE GIANT HT-VCL-30-P (1)(2)(3)(4)

Revisions: Date:

HGFECAwall face

FACE OF

BRICK

6D

KEY PLAN

MAIN

ENTRY

BUILDING 55

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459

NON-SPRINKLERED

Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:3

:5

P

M

B55-M100

BASEMENT LEVEL FLOOR PLAN -

MECHANICAL- DEMO

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B55

04/15/2022 JMM GTS

16181

52 176

1/8" = 1'-0" F3

BASEMENT LEVEL FLOOR PLAN - MECHANICAL - DEMO

SHEET NOTES:

1. DEMOLISH EXISTING 10 INCH OA DUCT AND PLENUM. PATCH WALL TO MATCH EXISTING CONSTRUCTION.

REFER TO NEW WORK FOR DUCT REROUTE.

2. REMOVE SECTIONS OF EXISTING SPRINKLER PIPING IN AREA OF NEW CONSTRUCTION. REFER TO NEW

WORK PLAN FOR ADDITIONAL INFORMATION.

3. REMOVE SECTION OF ONE INCH DOMESTIC COLD WATER THAT ROUTES THROUGH PROPOSED TR ROOM.

REFER TO NEW PLAN FOR PIPE REROUTE.

4. REMOVE SECTION OF EXISTING SUPPLY AIR DUCT. REFER TO NEW PLAN FOR DUCT MODIFICATIONS TO

ALLOW FOR WALKING ACCESS.

5. REMOVE 4 INCH ABANDONED SANITARY SEWER LINE .

6. REMOVE 3 INCH PVC COMBUSTION AND AIR INTAKE DUCTS FROM VERTICAL RISER BACK TO AIR HANDLING

UNIT TO ALLOW ROUTING OF RELOCATED OUTSIDE AIR DUCT. REFER TO NEW WORK PLAN FOR GUIDELINES

ON REINSTALLATION OF PVC DUCTS.

0 8' 16'4'

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

GENERAL NOTES:

PHOTO 01

PHOTO 02

INDICATES POINT OF VIEW OF REFERENCE PHOTO ON SHEET WITH CORRESPONDING NUMBER.##

HT

STORAGE

002A

STAIR

CRAWL SPACE

CRAWL SPACE

STORAGE

FMS

002B

ELEVATOR MECH

CRAWL SPACE

002D

STORAGE

ELEV

P1

TR

002C

ELEC

HGFECAwall face

FACE OF

BRICK

6D

B55-M400

F1

1" DCW

PC

1" DCW

3/4" PC

1" PC

1" DCW

12x16

10ø OA

PC

1/2" NPW

1/2" DCW

KEY PLAN

MAIN

ENTRY

BUILDING 55

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459

NON-SPRINKLERED

Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:3

:0

P

M

B55-M200

BASEMENT LEVEL FLOOR PLAN -

MECHANICAL

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B55

04/15/2022 JMM GTS

16181

53 176

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

SHEET NOTES:

1. EXTEND 10" OA DUCT THROUGH WALL AND EXPAND TO 14"X14" BEVELED INLET.

2. CONNECT NEW 1/2" DOMESTIC COLD WATER LINE TO EXISTING. PROVIDE REDUCED PRESSURE ZONE

BACKFLOW PREVENTER ON WALL AND ROUTE DRAIN LINE TO FLOOR DRAIN. ROUTE 1/2" NON-POTABLE COLD WATER TO NEW HUMIDIFIER AND ASSOCIATED RO SYSTEM IN TR ROOM. PROVIDE DRAIN PAN UNDER

WATER LINE WITHIN TR ROOM WITH WATER BUG ALARM TO BMS.

3. ROUTE REFRIGERANT LINES THROUGH CRAWL SPACE TO EXTERIOR CONDENSERS. REFER TO B55-M201 FOR GRADE LOCATION. PIPE SIZES SHOWN ARE FOR COST ESTIMATING PUPOSES. SIZE LINES ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL ACCESSORIES REQUIRED FOR A COMPLETE AND

OPERABLE SYSTEM.

4. REINSTALL 3 IN PVC COMBUSTION AND AIR INTAKE DUCTS TO ACCOMMMODATE NEW OUTSIDE AIR DUCT.

RAISE PIPE ELEVATIONS APPROXIMATELY ONE FOOT FROM ORIGINAL ELEVATION AND STAND OFF WALL APPROXIMATLEY 6 INCHES TO ACCOMMODATE EXISTING NATURAL GAS LINE. SLOPE COMBUSTION AIR

DUCT BACK TO FURNACE.

5. RELOCATED PUMPED CONDENSATE LINE SERVING EXISTING AIR HANDLING UNIT, MATCH EXISTING SIZE.

GENERAL NOTES:

1/8" = 1'-0" F3

BASEMENT LEVEL FLOOR PLAN - MECHANICAL

0 8' 16'4'

ELEVATOR

P-1

Room

STORAGE

103A

STORAGE

102A

Room

Room

STORAGE

OFFICE

BREAKROOM

BATH

101B

BATH

DOCK

100A

VESTIBULE

VESTIBULE

103B

VESTIBULE

101A

OFFICE

Room

P7

Room

P8

Room

P3

Room

P4

OFFICE

RECEIVING

H.A.C.

OFFICE

OFFICE

Room

P5

STORAGE

Room

P2

STORAGE

Room

STORAGE

wallfaceHGFECAwall face

WALL FACE.

FACE OF

BRICK

6D

Room

P6

SSOU-55-002CA SSOU-55-002CB

M500

B7

KEY PLAN

MAIN

ENTRY

BUILDING 55

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459

NON-SPRINKLERED

Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:3

:0

P

M

B55-M201

FIRST LEVEL FLOOR PLAN -

MECHANICAL

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B55

04/15/2022 JMM GTS

16181

54 176

1/8" = 1'-0" F3

FIRST LEVEL FLOOR PLAN - MECHANICAL

SHEET NOTES:

1. REFRIGERANT LINES INTO CRAWL SPACE BENEATH STORAGE ROOM.

0 8' 16'4'

GENERAL NOTES:

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE

ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

HT

A

FACE OF

BRICK

TR

002C

SSIU-55-002CA

SSIU-55-002CB

6"x6"

D6

FDFD

6x6 SA

H-1

CP-1

3/4" CD 1" CD

3/4" PC

1/ 2"

N P

W

M501

D1

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459

NON-SPRINKLERED

Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:3

:0

P

M

B55-M400

MECHANICAL - ENLARGED PLANS EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B55

04/15/2022 JMM GTS

16181

55 176

1/2" = 1'-0" F1

ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM 002C

0 2' 4'1'

SHEET NOTES:

1. BOTTOM OF COOLING UNIT SHALL BE A MINIMUM OF 7-0” A.F.F. ADJUST MOUNTING HEIGHT TO AVOID

CONFLICTS WITH CABLE TRAY. MAINTAIN MANUFACTURERS SERVICE CLEARANCE RECOMMENDATIONS.

2. ROUTE 3/8" REFRIGERANT LIQUID LINE AND 5/8" REFRIGERANT HOT GAS LINE FROM CONDENSING UNIT TO

CORRESPONDING DUCT-FREE SYSTEM. PIPE SIZES ARE FOR COST ESTIMATING PURPOSES, AND BASED ON

BASIS OF DESIGN MANUFACTURE AS LISTED IN THE SCHEDULE. SIZE LINES ACCORDING TO

MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL ACCESSORIES REQUIRED FOR A COMPLETE AND

OPERABLE SYSTEM.

3. ROUTE 3/4” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-55-002CA SOUTH. COMBINE WITH SSIU-55-002CB CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS, COMBINE WITH HUMIDIFIER DRAIN

AND RO DRAIN LINE AND CONTINUE AS 1” LINE TO CP-1.

4. PROVIDE WATER BUG AT FLOOR TO ALARM TO DDC WHEN ACTIVATED.

5. SUPPLY DIFFUSER TO BE PLACED 6" AFF.

6. REVISE SPRINKLER LAYOUT IN TR002C AND SURROUNDING SPACE AS NECESSARY TO MEET CODE

REQUIRED SPRINKLER COVERAGE. PROVIDE SPRINKLER GUARDS ON ALL SPRINKLERS IN TR 002C.

7. CONNECT 1/2" NON-POTABLE WATER TO HUMIDIFER AND RO SYSTEM.

8. MAINTAIN HUMIDIFIER MANUFACTURERS REQUIRED “NON-WETTING” CLEARANCES FROM

HUMIDIFIER. COORDINATE WITH OTHER TRADES TO ENSURE NO SOLID SURFACES OR OBJECTS ARE

LOCATED WITHIN THE MANUFACTURES “NON-WETTING” DISTANCES.

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

GENERAL NOTES:

REMARKS:

1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.

2. PROVIDE THE FOLLOWING ACCESSORIES: MANUFACTURER'S DISCONNECT AND LINESET.

3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT

BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR

PRIOR TO ORDERING EQUIPMENT.

REMARKS:

1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.

2. PROVIDE CONCRETE PAD AND ANCHOR EXTERIOR UNIT TO PAD.

3. PROVIDE CURB RAILS AND ROOF SUPPORTS FOR OUTDOOR UNIT.

4. PROVIDE THE FOLLOWING ACCESSORIES: SINGLE POINT POWER CONNECTION, DISCONNECT, HAIL GUARDS, LOW AMBIENT KIT, WIND BAFFLES.

5. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT

BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR

PRIOR TO ORDERING EQUIPMENT.

REMARKS:

1. COORDINATE EXACT MODEL AND FRAME WITH CEILING / WALL TYPE.

2. WHEN INSTALLED IN A WALL, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE HORIZONTAL (PARALLEL TO THE FLOOR). WHEN INSTALLED IN A CEILING, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT

THE FRONT BLADES ARE PARALLEL TO THE LONG DIMENSION OF THE GRILLE.

REMARKS:

1. PROVIDE WITH INTEGRAL CONDENSATE COOLER, BLOWER PACK.

REMARKS:

1. PERFORMANCE BASED ON FLUID AND CONDITIONS INDICATED IN THIS SCHEDULE.

2. PROVIDE WITH HIGH WATER LEVEL (OVERFLOW DETECTION) SWITCH WITH TERMINAL FOR CONNECTION TO DDC

EXTERNAL ALARM.

3. PROVIDE WITH BRASS CHECK VALVE.

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459

NON-SPRINKLERED

Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:5

:5

A

M

B55-M600

MECHANICAL SCHEDULES EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B55

04/15/2022 JMM GTS

16181

56 176

SPLIT SYSTEM AIR CONDITIONER - INDOOR SCHEDULE

MARK

ROOM SERVED

NOMINAL

CAPACITY

[TONS]

TOTAL COOLING

CAPACITY

[MBH]

CONDENSATE DRAIN

SIZE

INDOOR UNIT ELECTRICAL DATA

MANUFACTURER REMARKSNAME NUMBER

DIMENSIONS [IN] EAT

(DB / WB)

[°F] MODEL FLA VOLTAGE PHASE MCA DISCONNECT BY SCCRLENGTH WIDTH HEIGHT

SSIU-55-002CA TR 002C 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-55-002CB TR 002C 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SPLIT SYSTEM AIR CONDITIONER - OUTDOOR SCHEDULE

MARK

ROOM SERVED

NOMINAL

CAPACITY

[TONS]

TOTAL COOLING

CAPACITY

[MBH]

OUTDOOR UNIT ELECTRICAL DATA

MANUFACTURER REMARKSNAME NUMBER

DIMENSIONS [IN] SUMMER AMBIENT

AIR

[°F]

WINTER AMBIENT

AIR

[°F]

OPERATING

WEIGHT

[LBS] MODEL FLA VOLTAGE PHASE MCA MOCP DISCONNECT BY SCCRLENGTH WIDTH HEIGHT

SSOU-55-002CA TR 002C 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241HA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-55-002CB TR 002C 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241HA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

DIFFUSER, REGISTER, AND GRILLE SCHEDULE

MARK IMAGE DESCRIPTION MAX S.P. MATERIAL FINISH

FACE SIZE

NECK SIZE AIRFLOW MANUFACTURER MODEL REMARKSLENGTH WIDTH

D6 DOUBLE DEFLECTION

SUPPLY GRILLE

0.10 in-wg STEEL PAINT, WHITE 6" 6" SEE PLAN SEE PLAN TITUS 300RL/SL (1)(2)

ELECTRODE STEAM HUMIDIFIER SCHEDULE

MARK SERVICE

MAKE UP WATER

CONNECTION SIZE

WATER PIPING ELECTRICAL DATA

MANUFACTURER MODEL REMARKS

CAPACITY

[LB / HR]

DRAIN PIPE CONNECTION

SIZE KW VOLTAGE PHASE

H-1 TR 002C 1/2" 5.6 3/4" 1.9 120 V 1 DRISTEEM XTR (1)

PUMP SCHEDULE

MARK

FLOW

[GPM]

TOTAL HEAD

[FT]

SHUT-OFF HEAD

[FT]

SUCTION /

DISCHARGE SIZE

[IN]

ELECTRICAL DATA

MANUFACTURER MODEL REMARKSHP FLA VOLTAGE

CP-1 200 20 32 3/8" 0.125 1.4 115 V LITTLE GIANT HT-VCL-30-P (1)(2)(3)

KEY PLAN

MAIN

ENTRY

BUILDING 65

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459

NON-SPRINKLERED

Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:4

:3

P

M

B65-M100

BASEMENT LEVEL FLOOR PLAN -

MECHANICAL - DEMO

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B65

04/15/2022 JMM GTS

16181

57 176

1/8" = 1'-0" F3

BASEMENT LEVEL FLOOR PLAN - MECHANICAL - DEMO

0 8' 16'4'

SHEET NOTES:

1. RELOCATE SANITARY PIPE OUTSIDE OF FUTURE TR SPACE.

2. RELOCATE GROUND SOURCE HEAT PUMP DISTRIBUTION PUMPS, HEAT EXCHANGERS AND ACCESSORIES TO

MECHANICAL SPACE TO THE NORTH. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION.

3. ELIMINATE HEATING HOT WATER PIPING AND UNIT HEATER INSIDE OF FUTURE TR SPACE.

GENERAL NOTES:

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE

ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

PHOTO 01 PHOTO 02 PHOTO 03

## INDICATES POINT OF VIEW OF REFERENCE PHOTO ON SHEET WITH CORRESPONDING NUMBER.

610-701.M.20220415 51
610-701.M.20220415 52
610-701.M.20220415 53
610-701.M.20220415 54
610-701.M.20220415 55
610-701.M.20220415 56
610-701.M.20220415 57

File details come from the government source that posted it. Updated .