Atch 21 - MECH 7 of 7 - DRAWINGS.pdf
PDF 17 MB Posted
- Attached to
- Y1AZ--EHRM Infrastructure Upgrades Construction - Marion Federal contract opportunity
- Solicitation number
- 36C77622B0040
About this file
This federal contract opportunity solicitation involves infrastructure upgrades and renovations to existing spaces at the Marion VA facility. The solicitation seeks contractors to perform electrical, HVAC, communication, physical security, and fiber infrastructure upgrades across multiple buildings on campus, including modification to impacted roads, walks, grading, drainage, and other utilities. Additional requirements include Data Center WAN updates and hazardous material abatement. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.
View the file
Other files for this federal contract opportunity
Show all 42
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A R
E A
A
A R
E A
D
A R
E A
B
A R
E A
E
A R
E A
B
A R
E A
E
A R
E A
C
A R
E A
F
AREA C
AREA B
AREA B
AREA A
2829303132333435
37383940
475052535557
30.2
43.9
39.1
40.9
46.5
R
V
U.8
V.9 W
Y
AB
AD.1
AH
AJ
AK
AE
SSOU-172-1C100A
SSOU-172-2C200B
SSOU-172-1C100B
SSOU-172-2C200A
SSOU-172-B015
SSOU-172-B005B
SSOU-172-B005A
M500
B1
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:4
:0
P
M
B172-M205-B
ROOF LEVEL FLOOR PLAN - AREA
B - MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B172
04/15/2022 JMM GTS
16181
147 176
1/8" = 1'-0" F3
ROOF LEVEL FLOOR PLAN - AREA B - MECHANICAL
0 8' 16'4'
SHEET NOTES:
1. LOCATE CONDENSING UNITS AT LEAST 10 FEET FROM
EDGE OF PARAPET.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL
SYSTEMS TO BE REMOVED ARE SHOWN HATCHED
AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO
REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED
WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN
THESE DOCUMENTS ARE APPLICABLE FOR ALL PIPING,
EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER
OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE
FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR
THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION
SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM
THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT,
PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW
HORIZONTAL PLUMBING OR MECHANICAL PIPING
LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER
BUG SENSORS WITH ALARM TO THE DDC.
BUILDING 172 PENTHOUSE
LOCATE CONDENSING UNITS ON THE
SOUTH SIDE OF PENTHOUSE IN THIS
AREA. MAINTAIN A DISTANCE OF 10
FEET FROM THE EDGE OF PARAPET.
PHOTO 01
INDICATES POINT OF VIEW OF REFERENCE PHOTO
IN SHEET WITH CORRESPONDING NUMBER.
Revisions: Date:
E A
A
A R
E A
D
A R
E A
B
A R
E A
E
A R
E A
B
A R
E A
E
A R
E A
C
A R
E A
F
AREA F
AREA E
AREA E
AREA D
13581112
15161718192021
23242526
282930 13.6
16.117.9
30.2
26.8
11.5
R
V
U.8
V.9 W
Y
AB
AD.1
AH
AJ
AK
AM
AE
SSOU-172-1D100B
SSOU-172-2D200A
SSOU-172-2D200B
SSOU-172-1D100A
M500
B1
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:4
:0
P
M
B172-M205-E
ROOF LEVEL FLOOR PLAN - AREA
E - MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B172
04/15/2022 JMM GTS
16181
148 176
1/8" = 1'-0" F3
ROOF LEVEL FLOOR PLAN - AREA E - MECHANICAL
0 8' 16'4'
SHEET NOTES:
1. LOCATE CONDENSING UNITS AT LEAST 10 FEET FROM EDGE OF PARAPET.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.
LOCATE CONDENSING UNITS ON THE
NORTH SIDE OF PENTHOUSE IN THIS
AREA. MAINTAIN A DISTANCE OF 10
FEET FROM THE EDGE OF PARAPET.
BUILDING 172 PENTHOUSE
PHOTO 01
INDICATES POINT OF VIEW OF REFERENCE PHOTO IN SHEET WITH CORRESPONDING NUMBER.##
T H
HT
HT
HT T H
323334
P.8
R
SSIU-172-1C100A
SSIU-172-1C100B
OFFICE
1C-102
TR
1C-100
8x8 SA
D2
6"x6"
CP-2
3/4" CD UP
1" CD
6ø
6x6
3/4" PC
FDFD
232425
P.8
R
SSIU-172-1D100A
SSIU-172-1D100B
TR
1D-100
OFFICE
1D-102
100 100
6x6
D2
6"x6"
8x8
3/4" CD UP
26x20 SA
1" CD
FDFD
30.2
V.9
W
Y
ENTRANCE
FACILITY
B005
SSIU-172-B005A
SSIU-172-B005B
3/4" CD
3/4" PC
SSIU-172-B015 1
1" CD
CP-1
323334
P.8
R
TR
2C-200
OFFICE
2C-202
3/4" CD DN
100 100
8x8
6x6
D2
6"x6"
SSIU-172-2C200B
SSIU-172-2C200A
FDFD
232425
P.8P.8
R
TR
2D-200
OFFICE
2D-202
3/4" CD DN
SSIU-172-2D200B
SSIU-172-2D200A
D2
6"x6"
100 100
6x6
8x8
2 FDFD
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:4
:1
P
M
B172-M400
MECHANICAL - ENLARGED PLANS EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B172
04/15/2022 JMM GTS
16181
149 176
1/4" = 1'-0" C4
ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM 1C-100
0 4' 8'2'
1/4" = 1'-0" F1
ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM 1D-100
0 4' 8'2'
SHEET NOTES:
1. BOTTOM OF NEW EQUIPMENT SHALL BE 7'-6" ABOVE FINISHED FLOOR.
2. ROUTE REFRIGERANT SUCTION AND LIQUID LINES FROM CONDENSING UNIT TO CORRESPONDING DUCT-
FREE SYSTEM. PIPE SIZES SHOWN ARE FOR COST ESTIMATING PUPOSES. SIZE LINES ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL ACCESSORIES REQUIRED FOR A COMPLETE AND
OPERABLE SYSTEM.
3. ROUTE ¾” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-172-1C100B NORTH. COMBINE WITH SSIU-172-1C100A CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS AS 3/4” LINE TO
CP-1.
4. REBALANCE EXISTING RETURN GRILLE TO 110 CFM.
5. REBALANCE EXISTING SUPPLY GRILLE TO 220 CFM.
6. ROUTE ¾” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-172-B005B NORTH. COMBINE WITH SSIU-172-B005A
CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS, COMBINE WITH SSIU-172-B015
DRAIN LINE AND CONTINUE AS 1” LINE TO CP-1.
7. PROVIDE WATER BUG AT FLOOR TO ALARM TO DDC WHEN ACTIVATED.
8. ROUTE REFRIGERANT LINES UP TO AIR COOLED CONDENSING UNITS ON LEVEL 2 ROOF.
9. LOCATE NEW SPRINKLERS IN SPACE TO ACCOMMODATE NEW ROOM LAYOUT. PROVIDE SPRINKLER GUARDS
ON ALL SPRINKLERS IN TR ROOM.
10. REINSTALL SALVAGED RETURN GRILL AND SUPPLY DIFFUSER AND BALANCE TO CFM INDICATED ON PLANS.
11. CONNECT 3/4" PUMPED CONDENSATE INTO 1" CONDENSATE DRAIN LINE. PUMPED CONDENSATE SHALL
SLOPE TOWARDS GRVITY CONDENSATE DRAIN.
12. ROUTE ¾” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-172-1D100B NORTH. COMBINE WITH
SSIU-172-1D100A CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS AS 3/4” LINE TO
CP-1.
13. ROUTE REFRIGERANT LINES DN TO COOLING UNITS IN TR ROOM ON FIRST FLOOR.
14. ROUTE ¾” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-172-2C200A NORTH. COMBINE WITH
SSIU-172-2C200B CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS AS 3/4” LINE DN TO
FIRST FLOOR.
15. ROUTE ¾” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-172-2D200A NORTH. COMBINE WITH SSIU-172-2D200B CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS AS 3/4” LINE DN TO
FIRST FLOOR.
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.
GENERAL NOTES:
1/4" = 1'-0" C1
ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM B005
0 4' 8'2'
NOT TO SCALEF4
ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM 2C-200
NOT TO SCALEF7
ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM 2D-200
0 4' 8'2' 0 4' 8'2'
REMARKS:
1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.
2. PROVIDE THE FOLLOWING ACCESSORIES: MANUFACTURER'S DISCONNECT AND LINESET.
3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT
BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR
PRIOR TO ORDERING EQUIPMENT.
REMARKS:
1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.
2. PROVIDE CONCRETE PAD AND ANCHOR EXTERIOR UNIT TO PAD.
3. PROVIDE CURB RAILS AND ROOF SUPPORTS FOR OUTDOOR UNIT.
4. PROVIDE THE FOLLOWING ACCESSORIES: SINGLE POINT POWER CONNECTION, DISCONNECT, HAIL GUARDS, LOW AMBIENT KIT, WIND BAFFLES.
5. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT
BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR
PRIOR TO ORDERING EQUIPMENT.
REMARKS:
1. PERFORMANCE BASED ON FLUID AND CONDITIONS INDICATED IN THIS SCHEDULE.
2. PROVIDE WITH HIGH WATER LEVEL (OVERFLOW DETECTION) SWITCH WITH TERMINAL FOR CONNECTION TO DDC
EXTERNAL ALARM.
3. PROVIDE WITH 6’, 3-CONDUCTOR CABLE WITH GROUNDED 3-PRONGE PLUG.
4. MAXIMUM 5’ OF 3/8” VINYL DISCHARGE TUBING FOR TRANSITION CONNECTION TO COPPER PUMPED CONDENSATE
PIPING.
REMARKS:
1. COORDINATE EXACT MODEL AND FRAME WITH CEILING / WALL TYPE.
2. WHEN INSTALLED IN A WALL, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE HORIZONTAL (PARALLEL TO THE
FLOOR). WHEN INSTALLED IN A CEILING, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE PARALLEL TO THE LONG
DIMENSION OF THE GRILLE.
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:4
:1
P
M
B172-M600
MECHANICAL SCHEDULES EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B172
04/15/2022 JMM GTS
16181
150 176
SPLIT SYSTEM AIR CONDITIONER - INDOOR SCHEDULE
MARK
ROOM SERVED
NOMINAL
CAPACITY
[TONS]
TOTAL COOLING
CAPACITY
[MBH]
CONDENSATE DRAIN
SIZE
INDOOR UNIT ELECTRICAL DATA
MANUFACTURER REMARKSNAME NUMBER
DIMENSIONS [IN] EAT
(DB / WB)
[°F] MODEL FLA VOLTAGE PHASE MCA DISCONNECT BY SCCRLENGTH WIDTH HEIGHT
SSIU-172-1C100A TR 1C-100 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-172-1C100B TR 1C-100 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-172-1D100A TR 1D-100 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-172-1D100B TR 1D-100 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-172-2C200A TR 2C-200 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-172-2C200B TR 2C-200 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-172-2D200A TR 2D-200 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-172-2D200B TR 2D-200 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-172-B005A ENTRANCE FACILITY B005 3.0 36 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0361KA70A 0.57 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-172-B005B ENTRANCE FACILITY B005 3.0 36 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0361KA70A 0.57 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-172-B015 ELEC B015 2.0 24 3/4" 36 7/16" 9 3/16" 12 11/16" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SPLIT SYSTEM AIR CONDITIONER - OUTDOOR SCHEDULE
MARK
ROOM SERVED
NOMINAL
CAPACITY
[TONS]
TOTAL COOLING
CAPACITY
[MBH]
OUTDOOR UNIT ELECTRICAL DATA
MANUFACTURER REMARKSNAME NUMBER
DIMENSIONS [IN] SUMMER AMBIENT
AIR
[°F]
WINTER AMBIENT
AIR
[°F]
OPERATING
WEIGHT
[LBS] MODEL FLA VOLTAGE PHASE MCA MOCP DISCONNECT BY SCCRLENGTH WIDTH HEIGHT
SSOU-172-1C100A TR 1C-100 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-172-1C100B TR 1C-100 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-172-1D100A TR 1D-100 2.0 24 38" 11 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-172-1D100B TR 1D-100 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-172-2C200A TR 2C-200 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-172-2C200B TR 2C-200 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-172-2D200A TR 2D-200 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-172-2D200B TR 2D-200 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-172-B005A ENTRANCE FACILITY B005 3.0 36 41 5/16" 13" 52 11/16" 95 / 75 -10 211 TRUYA0361KA70NA 8 208 V 1 25 31 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-172-B005B ENTRANCE FACILITY B005 3.0 36 41 5/16" 13" 52 11/16" 95 / 75 -10 211 TRUYA0361KA70NA 8 208 V 1 25 31 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-172-B015 ELEC B015 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
PUMP SCHEDULE
MARK
FLOW
[GPH]
TOTAL HEAD
[FT]
SHUT-OFF HEAD
[FT]
SUCTION /
DISCHARGE SIZE
[IN]
ELECTRICAL DATA
MANUFACTURER MODEL REMARKSHP FLA VOLTAGE
CP-1 10 20 21 3/8" 0.033 1.5 115 V LITTLE GIANT VCMX-20ULS (1)(2)(3)(4)
CP-2 10 20 21 3/8" 0.033 1.5 115 V LITTLE GIANT VCMX-20ULS (1)(2)(3)(4)
CP-2 10 20 21 3/8" 0.033 1.5 115 V LITTLE GIANT VCMX-20ULS (1)(2)(3)(4)
DIFFUSER, REGISTER, AND GRILLE SCHEDULE
MARK IMAGE DESCRIPTION MAX S.P. MATERIAL FINISH
FACE SIZE
NECK SIZE AIRFLOW MANUFACTURER MODEL REMARKSLENGTH WIDTH
D2 DOUBLE DEFLECTION
SUPPLY GRILLE
0.10 in-wg STEEL PAINT, WHITE SEE PLAN SEE PLAN SEE PLAN SEE PLAN TITUS
KRUEGER
PRICE
300RL/SL
(1)(2)
TH
A B C D E
TOILET
TOILET
CORRIDOR
C101
CORRIDOR
C100
BREAKROOM /
WORK ROOM
CORRIDOR
C103
GREENHOUSE
CORRIDOR
C102
GREENHOUSE
OFFICE
A B C D E
B173-M400
F3
TR
SSIU-173-109A
SSOU-173-109A
SSOU-173-109B
SSIU-173-109B
M500
B7
G1
12x12
KEY PLAN
MAIN
ENTRY
BUILDING 173
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459
NON-SPRINKLERED
Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:5
:3
P
M
B173-M201
FIRST LEVEL FLOOR PLAN -
MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B173
04/15/2022 JMM GTS
16181
151 176
1/4" = 1'-0" F3
FIRST LEVEL FLOOR PLAN - MECHANICAL
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.
GENERAL NOTES:
0 4' 8'2'
A
SSIU-173-109A1
REFS
REFL
SSIU-173-109B
TR
6"x6"
G6
PF-1
F-1
FDFD
12x12
3/4" CD
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459
NON-SPRINKLERED
Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:5
:4
P
M
B173-M400
MECHANCIAL - ENLARGED PLANS EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B173
04/15/2022 JMM GTS
16181
152 176
1/2" = 1'-0" F3
ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM 109
0 2' 4'1'
SHEET NOTES:
1. BOTTOM OF COOLING UNIT SHALL BE A MINIMUM OF 7-0” A.F.F. ADJUST MOUNTING HEIGHT TO AVOID
CONFLICTS WITH CABLE TRAY. MAINTAIN MANUFACTURERS SERVICE CLEARANCE RECOMMENDATIONS.
2. ROUTE 3/8" REFRIGERANT LIQUID LINE AND 5/8" REFRIGERANT HOT GAS LINE FROM CONDENSING UNIT TO
CORRESPONDING DUCT-FREE SYSTEM. PIPE SIZES ARE FOR COST ESTIMATING PURPOSES, AND BASED ON
BASIS OF DESIGN MANUFACTURE AS LISTED IN THE SCHEDULE. SIZE LINES ACCORDING TO
MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL ACCESSORIES REQUIRED FOR A COMPLETE AND
OPERABLE SYSTEM.
3. ROUTE ¾” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-173-109A NORTH. COMBINE WITH SSIU-173-109B CONDENSATE DRAIN LINE. CONTINUE GRAVITY 3/4" CONDENSATE DRAIN LINE AS SHOWN ON PLANS AND
DRAIN CONDENSATE TO ADJACENT GRADE.
4. PROVIDE WATER BUG AT FLOOR TO ALARM TO DDC WHEN ACTIVATED.
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.
GENERAL NOTES:
2. PROVIDE THE FOLLOWING ACCESSORIES: MANUFACTURER'S DISCONNECT AND LINESET.
3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT
BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR
PRIOR TO ORDERING EQUIPMENT.
REMARKS:
1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.
2. PROVIDE CONCRETE PAD AND ANCHOR EXTERIOR UNIT TO PAD.
3. PROVIDE CURB RAILS AND ROOF SUPPORTS FOR OUTDOOR UNIT.
4. PROVIDE THE FOLLOWING ACCESSORIES: SINGLE POINT POWER CONNECTION, DISCONNECT, HAIL GUARDS, LOW AMBIENT KIT, WIND BAFFLES.
5. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT
BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR
PRIOR TO ORDERING EQUIPMENT.
REMARKS:
1. PROVIDE MAGNAHELIC GAUGE ACROSS HOUSING FILTER.
2. PROVIDE FILTER BANK HOLDING FRAME. SUPPORT FRAME FROM STRUCTURE.
REMARKS:
1. PROVIDE DISCONNECT.
2. PROVIDE VIBRATION ISOLATION.
3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT BASED
ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING
EQUIPMENT.
REMARKS:
1. COORDINATE EXACT MODEL AND FRAME WITH CEILING / WALL TYPE.
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459
NON-SPRINKLERED
Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:5
:4
P
M
B173-M600
MECHANICAL SCHEDULES EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B173
04/15/2022 JMM GTS
16181
153 176
SPLIT SYSTEM AIR CONDITIONER - INDOOR SCHEDULE
MARK
ROOM SERVED
NOMINAL
CAPACITY
[TONS]
TOTAL COOLING
CAPACITY
[MBH]
CONDENSATE DRAIN
SIZE
INDOOR UNIT ELECTRICAL DATA
MANUFACTURER REMARKSNAME NUMBER
DIMENSIONS [IN] EAT
(DB / WB)
[°F] MODEL FLA VOLTAGE PHASE MCA DISCONNECT BY SCCRLENGTH WIDTH HEIGHT
SSIU-173-109A TR 109 2.5 30 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0301KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-173-109B TR 109 2.5 30 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0301KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SPLIT SYSTEM AIR CONDITIONER - OUTDOOR SCHEDULE
MARK
ROOM SERVED
NOMINAL
CAPACITY
[TONS]
TOTAL COOLING
CAPACITY
[MBH]
OUTDOOR UNIT ELECTRICAL DATA
MANUFACTURER REMARKSNAME NUMBER
DIMENSIONS [IN] SUMMER AMBIENT
AIR
[°F]
WINTER AMBIENT
AIR
[°F]
OPERATING
WEIGHT
[LBS] MODEL FLA VOLTAGE PHASE MCA MOCP DISCONNECT BY SCCRLENGTH WIDTH HEIGHT
SSOU-173-109A TR 109 2.5 30 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0301HA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-173-109B TR 109 2.5 30 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0301HA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
DIFFUSER, REGISTER, AND GRILLE SCHEDULE
MARK IMAGE DESCRIPTION MAX S.P. MATERIAL FINISH
FACE SIZE
NECK SIZE AIRFLOW MANUFACTURER MODEL REMARKSLENGTH WIDTH
G1 PERFORATED RETURN
GRILLE
0.10 in-wg STEEL PAINT, WHITE 24" 24" 6"x6" 8"x8"
10"x10" 12"x12" 14"x14"
0-125 126-180 181-210 211-300 301-410
TITUS
KRUEGER
PRICE
PAR
PDDR
(1)
G6 SINGLE DEFLECTION
RETURN GRILLE
0.10 in-wg STEEL PAINT, WHITE 6" 6" SEE PLAN SEE PLAN TITUS 350RL/SL (1)
FAN SCHEDULE
MARK TYPE
MAX WEIGHT
[LBS]
AIRFLOW
[CFM]
TOTAL S.P.
[IN W.C.] MAX FAN RPM MAX FAN BHP
ELECTRICAL DATA
MANUFACTURER MODEL REMARKSFLA VOLTAGE PHASE DISCONNECT BY
F-1 IN-LINE 24 100 0.54 1288 0.03 1.5 115 V 1 MECHANICAL GREENHECK CSP-A390-VG (1)(2)(3)
FILTER SCHEDULE
MARK ASSOCIATED EQUIPMENT TYPE
DEPTH
[IN] MERV RATING REMARKS
PF-1 F-1 12"x12" 2" 11 (1)(2)
A B C D E G H J K L M N P Q R SB.5
2" HWS
2" HWR
1" 1"
48x30
KEY PLAN
MAIN
ENTRY
BUILDING 174
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
B174-M101
FIRST LEVEL FLOOR PLAN -
MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B174
04/15/2022 JMM GTS
16181
154 176
1/8" = 1'-0" F2
FIRST LEVEL FLOOR PLAN - MECHANICAL - DEMO
0 8' 16'4'
SHEET NOTES:
1. SALVAGE EXISTING TERMINAL BOX FOR RELOCATION UNDER NEW WORK.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.
T H
A B C D E G H J K L M N P Q R SB.5
FREEZER
118C
FREEZER
118B
FREEZER
118A
FREEZER
118D
DOCK OFFICE
(CLERK)
FOOD STORAGE
TR
UTILITY
H.A.C.
113A
CAFETERIA
SEATING
ASSISTANT CHIEF
OFFICE
103B
CHIEF OFFICE
103A
OFFICE
H.A.C.
100A
TOILET
111C
CLERK
104K
SUPERVISOR
104J
H.A.C.
ELECTRICAL
CORRIDOR
C1-10
CORRIDOR
CI-5
CORRIDOR
C1-1
STORAGE
ELEVATOR
256 STAIR
OFFICE
MENS TOILET
124A
H.A.C.
FOOD
PRODUCTION
OFFICE
LOUNGE
CORRIDOR
CI-3
FOOD SERVICE
COORD CENTER
CORRIDOR
CI-2
NON FOOD
STORAGE
CORRIDOR
CI-12
CORRIDOR
C1-11
OFFICE
101A
SEC. WAIT
STORAGE
FREEZER
110D
INGRED CONTROL
CLERK
MENS LOCKERS
124AA
WOMEN LOCKERS
124BB
WOMENS TOILET
124B
FMS
111B
SUBSISTENCE
STORAGE
STAIR
ELEVATOR
MAIN FOOD PREP
AREA
DISH WASHING
SHIPPING AND
RECIVING
CLINIC DIET
104A
CLINIC DIET
104B
STORAGE
104C
CLINIC DIET
104D
CLINIC DIET
104E
STORAGE
104F
TOILET
104G
STORAGE
CI-6
CLOSET
104L
DINING ROOM
COOK LINE
100B
LOBBY
CI-4
CORRIDOR
CI-8
B174-M400
D1
STORAGE
COOLER
RECEIVING AREA
111A
B174-M400
D4
KEY PLAN
MAIN
ENTRY
BUILDING 174
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
B174-M201
FIRST LEVEL FLOOR PLAN -
MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B174
04/15/2022 JMM GTS
16181
155 176
1/8" = 1'-0" F2
FIRST LEVEL FLOOR PLAN - MECHANICAL
0 8' 16'4'
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
A B C D E G H J K L M N P Q R SB.5
SSOU-174-110A
SSOU-174-110B
M500
B1
KEY PLAN
MAIN
ENTRY
BUILDING 174
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
B174-M202
ROOF LEVEL FLOOR PLAN -
MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B174
04/15/2022 JMM GTS
16181
156 176
1/8" = 1'-0" F2
ROOF LEVEL PLAN - MECHANICAL
0 8' 16'4'
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.
ROOF OF BUILDING 174
PHOTO 01
INDICATES POINT OF VIEW OF REFERENCE PHOTO ON SHEET WITH CORRESPONDING NUMBER.##
M N
TR
CORRIDOR
C1-10
SSIU-174-110B
SSIU-174-110A
DDC
D1
D3
D7
CP-1
FDFD
10x10 SA
10x10 SA
2" HWS
2" HWR
HWR
3/4" HWR
3/4" HWS
48x30 SA
RELOCATED
TERMINAL
UNIT
M N
CORRIDOR
C1-10
SSIU-174-110BSSIU-174-110A
3/4" PC
DDC
CP-1
TR
UTILITY
ELECTRICAL
3/4" PC
V
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:3
P
M
B174-M400
MECHANICAL - ENLARGED PLANS EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B174
04/15/2022 JMM GTS
16181
157 176
1/4" = 1'-0" D1
ENLARGED MECHANICAL PLAN - ROOM 110
0 2' 4'1'
SHEET NOTES:
1. BOTTOM OF NEW EQUIPMENT SHALL BE 7'-6" ABOVE FINISHED FLOOR.
2. ROUTE 3/8" REFRIGERANT LIQUID LINE AND 5/8" REFRIGERANT HOT GAS LINE FROM CONDENSING UNIT TO
CORRESPONDING DUCT-FREE SYSTEM. PIPE SIZES ARE FOR COST ESTIMATING PURPOSES, AND BASED ON
BASIS OF DESIGN MANUFACTURE AS LISTED IN THE SCHEDULE. SIZE LINES ACCORDING TO
MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL ACCESSORIES REQUIRED FOR A COMPLETE AND
OPERABLE SYSTEM.
3. ROUTE 3/4” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-174-110A EAST. COMBINE WITH SSIU-174-110B CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS AND ROUTE 3/4" CONDENSATE
DRAIN TO CP-1.
4. PROVIDE WATER BUG AT FLOOR TO ALARM TO DDC WHEN ACTIVATED.
5. ROUTE 3/4" PUMPED CONDENSATE FROM CP-1 ABOVE CEILING OF UTILITY ROOM AND DROP DOWN
THROUGH CEILING AT MOP SINK. SEAL PENETRATION OF CEILING WATER TIGHT AND ROUTE CONDENSATE DOWN WALL AND DISCHARGE WITHIN TWO INCHES OF MOP SINK IN UTILITY 107 AND DISCHARGE WITH ONE
INCH AIR GAP.
6. LOCATE NEW SPRINKLERS IN SPACE TO ACCOMMODATE NEW ROOM LAYOUT. PROVIDE SPRINKLER GUARDS
ON ALL SPRINKLERS IN TR ROOM.
7. REFRIGERANT LINES UP THROUGH ROOF TO AIR COOLED CONDENSING UNIT.
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.
GENERAL NOTES:
1/4" = 1'-0" D4
ENLARGED PLUMBING PLAN - ROOM 110
0 2' 4'1'
2. PROVIDE THE FOLLOWING ACCESSORIES: MANUFACTURER'S DISCONNECT AND LINESET.
3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT
BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR
PRIOR TO ORDERING EQUIPMENT.
REMARKS:
1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.
2. PROVIDE CONCRETE PAD AND ANCHOR EXTERIOR UNIT TO PAD.
3. PROVIDE CURB RAILS AND ROOF SUPPORTS FOR OUTDOOR UNIT.
4. PROVIDE THE FOLLOWING ACCESSORIES: SINGLE POINT POWER CONNECTION, DISCONNECT, HAIL GUARDS, LOW AMBIENT KIT, WIND BAFFLES.
5. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT
BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR
PRIOR TO ORDERING EQUIPMENT.
REMARKS:
1. PERFORMANCE BASED ON FLUID AND CONDITIONS INDICATED IN THIS SCHEDULE.
2. PROVIDE WITH HIGH WATER LEVEL (OVERFLOW DETECTION) SWITCH WITH TERMINAL FOR CONNECTION TO DDC
EXTERNAL ALARM.
3. PROVIDE WITH 6’, 3-CONDUCTOR CABLE WITH GROUNDED 3-PRONGE PLUG.
4. MAXIMUM 5’ OF 3/8” VINYL DISCHARGE TUBING FOR TRANSITION CONNECTION TO COPPER PUMPED CONDENSATE
PIPING.
REMARKS:
1. COORDINATE EXACT MODEL AND FRAME WITH CEILING / WALL TYPE.
2. WHEN INSTALLED IN A WALL, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE HORIZONTAL (PARALLEL TO THE
FLOOR). WHEN INSTALLED IN A CEILING, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE PARALLEL TO THE LONG
DIMENSION OF THE GRILLE.
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:3
P
M
B174-M600
MECHANICAL SCHEDULES EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B174
04/15/2022 JMM GTS
16181
158 176
SPLIT SYSTEM AIR CONDITIONER - INDOOR SCHEDULE
MARK
ROOM SERVED
NOMINAL
CAPACITY
[TONS]
TOTAL COOLING
CAPACITY
[MBH]
CONDENSATE DRAIN
SIZE
INDOOR UNIT ELECTRICAL DATA
MANUFACTURER REMARKSNAME NUMBER
DIMENSIONS [IN] EAT
(DB / WB)
[°F] MODEL FLA VOLTAGE PHASE MCA DISCONNECT BY SCCRLENGTH WIDTH HEIGHT
SSIU-174-110A TR 110 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-174-110B TR 110 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SPLIT SYSTEM AIR CONDITIONER - OUTDOOR SCHEDULE
MARK
ROOM SERVED
NOMINAL
CAPACITY
[TONS]
TOTAL COOLING
CAPACITY
[MBH]
OUTDOOR UNIT ELECTRICAL DATA
MANUFACTURER REMARKSNAME NUMBER
DIMENSIONS [IN] SUMMER AMBIENT
AIR
[°F]
WINTER AMBIENT
AIR
[°F]
OPERATING
WEIGHT
[LBS] MODEL FLA VOLTAGE PHASE MCA MOCP DISCONNECT BY SCCRLENGTH WIDTH HEIGHT
SSOU-174-110A TR 110 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-174-110B TR 110 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
PUMP SCHEDULE
MARK
FLOW
[GPH]
TOTAL HEAD
[FT]
SHUT-OFF HEAD
[FT]
SUCTION /
DISCHARGE SIZE
[IN]
ELECTRICAL DATA
MANUFACTURER MODEL REMARKSHP FLA VOLTAGE
CP-1 10 20 21 3/8" 0.033 1.5 115 V LITTLE GIANT VCMX-20ULS (1)(2)(3)(4)
DIFFUSER, REGISTER, AND GRILLE SCHEDULE
MARK IMAGE DESCRIPTION MAX S.P. MATERIAL FINISH
FACE SIZE
NECK SIZE AIRFLOW MANUFACTURER MODEL REMARKSLENGTH WIDTH
D3 PLAQUE FACE STYLE
SUPPLY DIFFUSER
0.10 in-wg STEEL PAINT, WHITE 12" 12" 6" 8"
0-140 141-210
TITUS
KRUEGER
PRICE
OMNI
PLQ
SPD
(1)
D7 DOUBLE DEFLECTION
SUPPLY GRILLE
0.10 in-wg STEEL PAINT, WHITE SEE PLAN SEE PLAN SEE PLAN SEE PLAN TITUS
KRUEGER
PRICE
300RL/SL
(1)(2)
EPO EPO
EPO
A B C
STAIR
#1
GENERATION
ROOM
MAIN ELECTRICAL
ROOM
1 1
KEY PLAN
MAIN
ENTRY
BUILDING 175
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:5
A
M
B175-M101
FIRST LEVEL FLOOR PLAN -
MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B175
04/15/2022 JMM GTS
16181
159 176
0 8' 16'4'
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
1/8" = 1'-0" E4
FIRST LEVEL FLOOR PLAN - MECHANICAL - DEMO
PHOTO 01
SHEET NOTES:
1. REMOVE EXISTING LOUVER BLANK OFF PANELS.
E
E
EPO EPO
EPO EPO
E
A B C
STAIR
#1
GENERATION
ROOM
MAIN ELECTRICAL
ROOM
D-3
D-1
D-2
INTAKE
EXHAUST
6 EA UP
KEY PLAN
MAIN
ENTRY
BUILDING 175
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:5
A
M
B175-M201
FIRST LEVEL FLOOR PLAN -
MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B175
04/15/2022 JMM GTS
16181
160 176
0 8' 16'4'
SHEET NOTES:
1. PROVIDE 12'X12' INTAKE DAMPER. REFER TO PHOTO FOR EXAMPLE OF EXISTING.
2. 12'-0"x12'-0"x1'-0" DOUBLE WALL, INSULATED SHEET METAL PLENUM.
3. 12'-0"x12'-0"x1'-1" DOUBLE WALL, INSULATED SHEET METAL PLENUM. CONNECT TO GENERATOR RADIATOR.
4. PROVIDE 2'-0"x7'-0" BYPASS DAMPER.
5. EMERGENCY GENERATOR EXHAUST MUFFLER WITH 12" INCH INLET AND 12" INCH OUTLET. ROUTE 12" INCH
PIPE INLET TO GENERATOR AND REDUCE AT GENERATOR AS NECESSARY TO CONNECT TO GENERATOR FLEXT CONNECTION. DISCHARGE 12" INCH STEEL PIPE DISCHARGE THROUGH ROOF AS INDICATED. REFER
TO SPECIFICATION 263213 FOR PERFORMANCE AND CONSTRUCTION REQUIREMENTS.
6. 12" GENERATOR EXHAUST UP THROUGH ROOF. LOCATION IS APPROXIMATE. REFER TO PHOTO 01 THIS
SHEET FOR SIMILAR MUFFLER INSTALLTION.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
1/8" = 1'-0" E4
FIRST LEVEL FLOOR PLAN - MECHANICAL
PHOTO 01
A B C
EA DN
KEY PLAN
MAIN
ENTRY
BUILDING 175
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:5
A
M
B175-M202
ROOF LEVEL FLOOR PLAN -
MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B175
04/15/2022 JMM GTS
16181
161 176
0 8' 16'4'
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
1/8" = 1'-0" E4
ROOF LEVEL PLAN - MECHANICAL
E A
A
A R
E A
C
A R
E A
B
A R
E A
D
A R
E A
A
A R
E A
C
AREA C
A R
E A
B
A R
E A
D
AREA D
AREA A
AREA B
15.1
B1
B2
B3 B4
B5 B6
B7
B8
B7.1
B4.1
BA
BB
BC
BD
BD.1
A1
A2
A3
A4
A5
AA AB
AC
AD
AE
AF AG
AH
CA
CB
CC
CD
CE
CF
CG
CH
0.10.2
0.7
J.2J.1
A
B C
D
E
F
G H G.1
F.1E.2E.1
C.1A.2
J
D1
D2 D3
D4
D5 D6
D7
D8
D8.1
D8.2
DA
DB
DC
DD
DD.1
C1
C2
C3
C4
C5
KEY PLAN
MAIN
ENTRY
BUILDING 185
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:1
:2
P
M
B185-M101
FIRST LEVEL FLOOR PLAN -
OVERALL - MECHANICAL DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B185
04/15/2022 JMM GTS
16181
162 176
1/16" = 1'-0" F3
FIRST LEVEL FLOOR PLAN - MECHANICAL - DEMO - OVERALL*
0 16' 32'8'
E A
B
A R
E A
D
A R
E A
A
A R
E A
C
AREA C
A R
E A
B
A R
E A
D
AREA D
0.7 J.2J.1F G H G.1F.1E.2E.1 J
D1
D2
D3
D4
D5
D6
D7
D8
D8.1
D8.2
DA
DB
DC
DDDD.1
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:1
:2
P
M
B185-M101-D
FIRST LEVEL FLOOR PLAN - AREA
D - MECHANICAL DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B185
04/15/2022 JMM GTS
16181
163 176
1/8" = 1'-0"F3
FIRST LEVEL FLOOR PLAN - AREA D - MECHANICAL - DEMO
0 8' 16'4'
SHEET NOTES:
1. SALVAGE EXISTING TERMINAL AIR BOX AND RELOCATE AS SHOWN ON NEW WORK PLAN B185-F101D.
2. DEMOLISH EXISTING ROOM SPRINKLER HEADS. DEMOLISH EXISTING SPRINKLER PIPING AS NECESSARY TO
ACCOMMODATE NEW WORK PLAN.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.
E A
A
A R
E A
C
A R
E A
B
A R
E A
D
A R
E A
A
A R
E A
C
AREA C
A R
E A
B
A R
E A
D AREA D
AREA A
AREA B
15.1
B1
B2
B3 B4
B5 B6
B7
B8
B7.1
B4.1
BA
BB
BC
BD
BD.1
A1
A2
A3
A4
A5
AA AB
AC
AD
AE
AF AG
AH
CA
CB
CC
CD
CE
CF
CG
CH
0.10.2
0.7
J.2J.1
A
B C
D
E
F
G H G.1
F.1E.2E.1
C.1A.2
J
D1
D2 D3
D4
D5 D6
D7
D8
D8.1
D8.2
DA
DB
DC
DD
DD.1
C1
C2
C3
C4
C5
KEY PLAN
MAIN
ENTRY
BUILDING 185
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:1
:2
P
M
B185-M102
SECOND LEVEL FLOOR PLAN -
OVERALL - MECHANICAL DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B185
04/15/2022 JMM GTS
16181
164 176
1/16" = 1'-0" F3
SECOND LEVEL FLOOR PLAN - MECHANICAL - DEMO - OVERALL*
0 8' 16'4'
E A
B
A R
E A
D
A R
E A
A
A R
E A
C
AREA C
A R
E A
B
A R
E A
D
AREA D
0.7 J.2J.1F G H G.1F.1E.2E.1 J
D1
D2
D3
D4
D5
D6
D7
D8
D8.1
D8.2
DA
DB
DC
DDDD.1
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:1
:3
P
M
B185-M102-D
SECOND LEVEL FLOOR PLAN -
AREA D - MECHANICAL DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B185
04/15/2022 JMM GTS
16181
165 176
1/8" = 1'-0"F3
SECOND LEVEL FLOOR PLAN - AREA D - MECHANICAL - DEMO
0 8' 16'4'
SHEET NOTES:
1. SALVAGE EXISTING TERMINAL AIR BOX AND RELOCATE AS SHOWN ON NEW WORK PLAN B185-F201-D.
2. DEMOLISH EXISTING ROOM SPRINKLER HEADS. DEMOLISH EXISTING SPRINKLER PIPING AS NECESSARY TO
ACCOMMODATE NEW WORK PLAN.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR
R
E A
A
A R
E A
C
A R
E A
B
A R
E A
D
A R
E A
A
A R
E A
C
AREA C
A R
E A
B
A R
E A
D AREA D
AREA A
AREA B
15.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .