Atch 21 - MECH 7 of 7 - DRAWINGS.pdf

PDF 17 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction - Marion Federal contract opportunity
Solicitation number
36C77622B0040
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This federal contract opportunity solicitation involves infrastructure upgrades and renovations to existing spaces at the Marion VA facility. The solicitation seeks contractors to perform electrical, HVAC, communication, physical security, and fiber infrastructure upgrades across multiple buildings on campus, including modification to impacted roads, walks, grading, drainage, and other utilities. Additional requirements include Data Center WAN updates and hazardous material abatement. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction - Marion, newest first.
File Type Posted
Clarifications - Marion.pdf PDF
Atch 27 - Construction Wage Rates - Grant 8-19-22.pdf PDF
36C77622B0040 0005.pdf PDF
Technical Questions - FINAL - Marion 8-11-22.pdf PDF
36C77622B0040 0004.pdf PDF
Atch 27 - Construction Wage Rates - Grant 8-12-22.pdf PDF
03 30 00 - Cast-In-Place Concrete.pdf PDF
Atch 27 - Construction Wage Rates - Grant 7-15-22.pdf PDF
36C77622B0040 0003.pdf PDF
36C77622B0040 0002.pdf PDF
Atch 27 - Construction Wage Rates - Grant 7-8-22.pdf PDF
Site Visit Sign-in Sheet - Marion 7-11-22.pdf PDF
36C77622B0040 0001.pdf PDF
36C77622B0040 - 6-27-22.pdf PDF
Atch 3 - ARCH 1of 4 - DRAWINGS.pdf PDF
Atch 8 - CIVIL 2 of 2 - DRAWINGS.pdf PDF
Atch 26 - Limitations on Subcontracting - Construction.docx DOCX document
Atch 1 - SPECIFICATIONS.pdf PDF
Atch 4 - ARCH 2 of 4 - DRAWINGS.pdf PDF
Atch 5 - ARCH 3 of 4 - DRAWINGS.pdf PDF
Atch 9 - ELEC 1 of 3 - DRAWINGS.pdf PDF
Atch 10 - ELEC 2 of 3 - DRAWINGS.pdf PDF
Atch 12 - GENERAL - DRAWINGS.pdf PDF
Atch 16 - MECH 2 of 7 - DRAWINGS.pdf PDF
Atch 20 - MECH 6 of 7 - DRAWINGS.pdf PDF
Atch 23 - TELECOM 1 of 2 - DRAWINGS.pdf PDF
Atch 27 - Construction Wage Rates - Grant 6-10-22.pdf PDF
Atch 7 - CIVIL 1 of 2 - DRAWINGS.pdf PDF
Atch 11 - ELEC 3 of 3 - DRAWINGS.pdf PDF
Atch 13 - HAZARDOUS ASBESTOS - DRAWINGS.pdf PDF
Atch 14 - HAZARDOUS LEAD BASED PAINT - DRAWINGS.pdf PDF
Atch 22 - STRUCTURAL - DRAWINGS.pdf PDF
Atch 24 - TELECOM 2 of 2 - DRAWINGS.pdf PDF
Atch 25 - COVID-19 Safety Protocols 12-14-21.pdf PDF
Atch 15 - MECH 1 of 7 - DRAWINGS.pdf PDF
Atch 2 - DRAWINGS SHEET INDEX.pdf PDF
Atch 6 - ARCH 4 of 4 - DRAWINGS.pdf PDF
Atch 17 - MECH 3 of 7 - DRAWINGS.pdf PDF
Atch 18 - MECH 4 of 7 - DRAWINGS.pdf PDF
Atch 19 - MECH 5 of 7 - DRAWINGS.pdf PDF
Atch 28 - Contractor Safety - Environmental Form.docx DOCX document
Atch 29 - Site Visit Instructions.pdf PDF
Show all 42

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A R

E A

A

A R

E A

D

A R

E A

B

A R

E A

E

A R

E A

B

A R

E A

E

A R

E A

C

A R

E A

F

AREA C

AREA B

AREA B

AREA A

2829303132333435

37383940

475052535557

30.2

43.9

39.1

40.9

46.5

R

V

U.8

V.9 W

Y

AB

AD.1

AH

AJ

AK

AE

SSOU-172-1C100A

SSOU-172-2C200B

SSOU-172-1C100B

SSOU-172-2C200A

SSOU-172-B015

SSOU-172-B005B

SSOU-172-B005A

M500

B1

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:4

:0

P

M

B172-M205-B

ROOF LEVEL FLOOR PLAN - AREA

B - MECHANICAL

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B172

04/15/2022 JMM GTS

16181

147 176

1/8" = 1'-0" F3

ROOF LEVEL FLOOR PLAN - AREA B - MECHANICAL

0 8' 16'4'

SHEET NOTES:

1. LOCATE CONDENSING UNITS AT LEAST 10 FEET FROM

EDGE OF PARAPET.

GENERAL NOTES:

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL

SYSTEMS TO BE REMOVED ARE SHOWN HATCHED

AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO

REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED

WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN

THESE DOCUMENTS ARE APPLICABLE FOR ALL PIPING,

EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER

OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE

FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR

THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION

SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM

THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT,

PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW

HORIZONTAL PLUMBING OR MECHANICAL PIPING

LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE

ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER

BUG SENSORS WITH ALARM TO THE DDC.

BUILDING 172 PENTHOUSE

LOCATE CONDENSING UNITS ON THE

SOUTH SIDE OF PENTHOUSE IN THIS

AREA. MAINTAIN A DISTANCE OF 10

FEET FROM THE EDGE OF PARAPET.

PHOTO 01

INDICATES POINT OF VIEW OF REFERENCE PHOTO

IN SHEET WITH CORRESPONDING NUMBER.

Revisions: Date:

E A

A

A R

E A

D

A R

E A

B

A R

E A

E

A R

E A

B

A R

E A

E

A R

E A

C

A R

E A

F

AREA F

AREA E

AREA E

AREA D

13581112

15161718192021

23242526

282930 13.6

16.117.9

30.2

26.8

11.5

R

V

U.8

V.9 W

Y

AB

AD.1

AH

AJ

AK

AM

AE

SSOU-172-1D100B

SSOU-172-2D200A

SSOU-172-2D200B

SSOU-172-1D100A

M500

B1

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:4

:0

P

M

B172-M205-E

ROOF LEVEL FLOOR PLAN - AREA

E - MECHANICAL

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B172

04/15/2022 JMM GTS

16181

148 176

1/8" = 1'-0" F3

ROOF LEVEL FLOOR PLAN - AREA E - MECHANICAL

0 8' 16'4'

SHEET NOTES:

1. LOCATE CONDENSING UNITS AT LEAST 10 FEET FROM EDGE OF PARAPET.

GENERAL NOTES:

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE

ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

LOCATE CONDENSING UNITS ON THE

NORTH SIDE OF PENTHOUSE IN THIS

AREA. MAINTAIN A DISTANCE OF 10

FEET FROM THE EDGE OF PARAPET.

BUILDING 172 PENTHOUSE

PHOTO 01

INDICATES POINT OF VIEW OF REFERENCE PHOTO IN SHEET WITH CORRESPONDING NUMBER.##

T H

HT

HT

HT T H

323334

P.8

R

SSIU-172-1C100A

SSIU-172-1C100B

OFFICE

1C-102

TR

1C-100

8x8 SA

D2

6"x6"

CP-2

3/4" CD UP

1" CD

6ø

6x6

3/4" PC

FDFD

232425

P.8

R

SSIU-172-1D100A

SSIU-172-1D100B

TR

1D-100

OFFICE

1D-102

100 100

6x6

D2

6"x6"

8x8

3/4" CD UP

26x20 SA

1" CD

FDFD

30.2

V.9

W

Y

ENTRANCE

FACILITY

B005

SSIU-172-B005A

SSIU-172-B005B

3/4" CD

3/4" PC

SSIU-172-B015 1

1" CD

CP-1

323334

P.8

R

TR

2C-200

OFFICE

2C-202

3/4" CD DN

100 100

8x8

6x6

D2

6"x6"

SSIU-172-2C200B

SSIU-172-2C200A

FDFD

232425

P.8P.8

R

TR

2D-200

OFFICE

2D-202

3/4" CD DN

SSIU-172-2D200B

SSIU-172-2D200A

D2

6"x6"

100 100

6x6

8x8

2 FDFD

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:4

:1

P

M

B172-M400

MECHANICAL - ENLARGED PLANS EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B172

04/15/2022 JMM GTS

16181

149 176

1/4" = 1'-0" C4

ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM 1C-100

0 4' 8'2'

1/4" = 1'-0" F1

ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM 1D-100

0 4' 8'2'

SHEET NOTES:

1. BOTTOM OF NEW EQUIPMENT SHALL BE 7'-6" ABOVE FINISHED FLOOR.

2. ROUTE REFRIGERANT SUCTION AND LIQUID LINES FROM CONDENSING UNIT TO CORRESPONDING DUCT-

FREE SYSTEM. PIPE SIZES SHOWN ARE FOR COST ESTIMATING PUPOSES. SIZE LINES ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL ACCESSORIES REQUIRED FOR A COMPLETE AND

OPERABLE SYSTEM.

3. ROUTE ¾” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-172-1C100B NORTH. COMBINE WITH SSIU-172-1C100A CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS AS 3/4” LINE TO

CP-1.

4. REBALANCE EXISTING RETURN GRILLE TO 110 CFM.

5. REBALANCE EXISTING SUPPLY GRILLE TO 220 CFM.

6. ROUTE ¾” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-172-B005B NORTH. COMBINE WITH SSIU-172-B005A

CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS, COMBINE WITH SSIU-172-B015

DRAIN LINE AND CONTINUE AS 1” LINE TO CP-1.

7. PROVIDE WATER BUG AT FLOOR TO ALARM TO DDC WHEN ACTIVATED.

8. ROUTE REFRIGERANT LINES UP TO AIR COOLED CONDENSING UNITS ON LEVEL 2 ROOF.

9. LOCATE NEW SPRINKLERS IN SPACE TO ACCOMMODATE NEW ROOM LAYOUT. PROVIDE SPRINKLER GUARDS

ON ALL SPRINKLERS IN TR ROOM.

10. REINSTALL SALVAGED RETURN GRILL AND SUPPLY DIFFUSER AND BALANCE TO CFM INDICATED ON PLANS.

11. CONNECT 3/4" PUMPED CONDENSATE INTO 1" CONDENSATE DRAIN LINE. PUMPED CONDENSATE SHALL

SLOPE TOWARDS GRVITY CONDENSATE DRAIN.

12. ROUTE ¾” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-172-1D100B NORTH. COMBINE WITH

SSIU-172-1D100A CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS AS 3/4” LINE TO

CP-1.

13. ROUTE REFRIGERANT LINES DN TO COOLING UNITS IN TR ROOM ON FIRST FLOOR.

14. ROUTE ¾” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-172-2C200A NORTH. COMBINE WITH

SSIU-172-2C200B CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS AS 3/4” LINE DN TO

FIRST FLOOR.

15. ROUTE ¾” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-172-2D200A NORTH. COMBINE WITH SSIU-172-2D200B CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS AS 3/4” LINE DN TO

FIRST FLOOR.

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

GENERAL NOTES:

1/4" = 1'-0" C1

ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM B005

0 4' 8'2'

NOT TO SCALEF4

ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM 2C-200

NOT TO SCALEF7

ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM 2D-200

0 4' 8'2' 0 4' 8'2'

REMARKS:

1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.

2. PROVIDE THE FOLLOWING ACCESSORIES: MANUFACTURER'S DISCONNECT AND LINESET.

3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT

BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR

PRIOR TO ORDERING EQUIPMENT.

REMARKS:

1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.

2. PROVIDE CONCRETE PAD AND ANCHOR EXTERIOR UNIT TO PAD.

3. PROVIDE CURB RAILS AND ROOF SUPPORTS FOR OUTDOOR UNIT.

4. PROVIDE THE FOLLOWING ACCESSORIES: SINGLE POINT POWER CONNECTION, DISCONNECT, HAIL GUARDS, LOW AMBIENT KIT, WIND BAFFLES.

5. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT

BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR

PRIOR TO ORDERING EQUIPMENT.

REMARKS:

1. PERFORMANCE BASED ON FLUID AND CONDITIONS INDICATED IN THIS SCHEDULE.

2. PROVIDE WITH HIGH WATER LEVEL (OVERFLOW DETECTION) SWITCH WITH TERMINAL FOR CONNECTION TO DDC

EXTERNAL ALARM.

3. PROVIDE WITH 6’, 3-CONDUCTOR CABLE WITH GROUNDED 3-PRONGE PLUG.

4. MAXIMUM 5’ OF 3/8” VINYL DISCHARGE TUBING FOR TRANSITION CONNECTION TO COPPER PUMPED CONDENSATE

PIPING.

REMARKS:

1. COORDINATE EXACT MODEL AND FRAME WITH CEILING / WALL TYPE.

2. WHEN INSTALLED IN A WALL, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE HORIZONTAL (PARALLEL TO THE

FLOOR). WHEN INSTALLED IN A CEILING, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE PARALLEL TO THE LONG

DIMENSION OF THE GRILLE.

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:4

:1

P

M

B172-M600

MECHANICAL SCHEDULES EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B172

04/15/2022 JMM GTS

16181

150 176

SPLIT SYSTEM AIR CONDITIONER - INDOOR SCHEDULE

MARK

ROOM SERVED

NOMINAL

CAPACITY

[TONS]

TOTAL COOLING

CAPACITY

[MBH]

CONDENSATE DRAIN

SIZE

INDOOR UNIT ELECTRICAL DATA

MANUFACTURER REMARKSNAME NUMBER

DIMENSIONS [IN] EAT

(DB / WB)

[°F] MODEL FLA VOLTAGE PHASE MCA DISCONNECT BY SCCRLENGTH WIDTH HEIGHT

SSIU-172-1C100A TR 1C-100 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-172-1C100B TR 1C-100 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-172-1D100A TR 1D-100 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-172-1D100B TR 1D-100 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-172-2C200A TR 2C-200 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-172-2C200B TR 2C-200 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-172-2D200A TR 2D-200 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-172-2D200B TR 2D-200 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-172-B005A ENTRANCE FACILITY B005 3.0 36 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0361KA70A 0.57 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-172-B005B ENTRANCE FACILITY B005 3.0 36 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0361KA70A 0.57 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-172-B015 ELEC B015 2.0 24 3/4" 36 7/16" 9 3/16" 12 11/16" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SPLIT SYSTEM AIR CONDITIONER - OUTDOOR SCHEDULE

MARK

ROOM SERVED

NOMINAL

CAPACITY

[TONS]

TOTAL COOLING

CAPACITY

[MBH]

OUTDOOR UNIT ELECTRICAL DATA

MANUFACTURER REMARKSNAME NUMBER

DIMENSIONS [IN] SUMMER AMBIENT

AIR

[°F]

WINTER AMBIENT

AIR

[°F]

OPERATING

WEIGHT

[LBS] MODEL FLA VOLTAGE PHASE MCA MOCP DISCONNECT BY SCCRLENGTH WIDTH HEIGHT

SSOU-172-1C100A TR 1C-100 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-172-1C100B TR 1C-100 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-172-1D100A TR 1D-100 2.0 24 38" 11 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-172-1D100B TR 1D-100 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-172-2C200A TR 2C-200 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-172-2C200B TR 2C-200 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-172-2D200A TR 2D-200 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-172-2D200B TR 2D-200 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-172-B005A ENTRANCE FACILITY B005 3.0 36 41 5/16" 13" 52 11/16" 95 / 75 -10 211 TRUYA0361KA70NA 8 208 V 1 25 31 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-172-B005B ENTRANCE FACILITY B005 3.0 36 41 5/16" 13" 52 11/16" 95 / 75 -10 211 TRUYA0361KA70NA 8 208 V 1 25 31 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-172-B015 ELEC B015 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

PUMP SCHEDULE

MARK

FLOW

[GPH]

TOTAL HEAD

[FT]

SHUT-OFF HEAD

[FT]

SUCTION /

DISCHARGE SIZE

[IN]

ELECTRICAL DATA

MANUFACTURER MODEL REMARKSHP FLA VOLTAGE

CP-1 10 20 21 3/8" 0.033 1.5 115 V LITTLE GIANT VCMX-20ULS (1)(2)(3)(4)

CP-2 10 20 21 3/8" 0.033 1.5 115 V LITTLE GIANT VCMX-20ULS (1)(2)(3)(4)

CP-2 10 20 21 3/8" 0.033 1.5 115 V LITTLE GIANT VCMX-20ULS (1)(2)(3)(4)

DIFFUSER, REGISTER, AND GRILLE SCHEDULE

MARK IMAGE DESCRIPTION MAX S.P. MATERIAL FINISH

FACE SIZE

NECK SIZE AIRFLOW MANUFACTURER MODEL REMARKSLENGTH WIDTH

D2 DOUBLE DEFLECTION

SUPPLY GRILLE

0.10 in-wg STEEL PAINT, WHITE SEE PLAN SEE PLAN SEE PLAN SEE PLAN TITUS

KRUEGER

PRICE

300RL/SL

(1)(2)

TH

A B C D E

TOILET

TOILET

CORRIDOR

C101

CORRIDOR

C100

BREAKROOM /

WORK ROOM

CORRIDOR

C103

GREENHOUSE

CORRIDOR

C102

GREENHOUSE

OFFICE

A B C D E

B173-M400

F3

TR

SSIU-173-109A

SSOU-173-109A

SSOU-173-109B

SSIU-173-109B

M500

B7

G1

12x12

KEY PLAN

MAIN

ENTRY

BUILDING 173

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459

NON-SPRINKLERED

Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:5

:3

P

M

B173-M201

FIRST LEVEL FLOOR PLAN -

MECHANICAL

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B173

04/15/2022 JMM GTS

16181

151 176

1/4" = 1'-0" F3

FIRST LEVEL FLOOR PLAN - MECHANICAL

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

GENERAL NOTES:

0 4' 8'2'

A

SSIU-173-109A1

REFS

REFL

SSIU-173-109B

TR

6"x6"

G6

PF-1

F-1

FDFD

12x12

3/4" CD

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459

NON-SPRINKLERED

Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:5

:4

P

M

B173-M400

MECHANCIAL - ENLARGED PLANS EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B173

04/15/2022 JMM GTS

16181

152 176

1/2" = 1'-0" F3

ENLARGED MECHANICAL AND PLUMBING PLAN - ROOM 109

0 2' 4'1'

SHEET NOTES:

1. BOTTOM OF COOLING UNIT SHALL BE A MINIMUM OF 7-0” A.F.F. ADJUST MOUNTING HEIGHT TO AVOID

CONFLICTS WITH CABLE TRAY. MAINTAIN MANUFACTURERS SERVICE CLEARANCE RECOMMENDATIONS.

2. ROUTE 3/8" REFRIGERANT LIQUID LINE AND 5/8" REFRIGERANT HOT GAS LINE FROM CONDENSING UNIT TO

CORRESPONDING DUCT-FREE SYSTEM. PIPE SIZES ARE FOR COST ESTIMATING PURPOSES, AND BASED ON

BASIS OF DESIGN MANUFACTURE AS LISTED IN THE SCHEDULE. SIZE LINES ACCORDING TO

MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL ACCESSORIES REQUIRED FOR A COMPLETE AND

OPERABLE SYSTEM.

3. ROUTE ¾” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-173-109A NORTH. COMBINE WITH SSIU-173-109B CONDENSATE DRAIN LINE. CONTINUE GRAVITY 3/4" CONDENSATE DRAIN LINE AS SHOWN ON PLANS AND

DRAIN CONDENSATE TO ADJACENT GRADE.

4. PROVIDE WATER BUG AT FLOOR TO ALARM TO DDC WHEN ACTIVATED.

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

GENERAL NOTES:

2. PROVIDE THE FOLLOWING ACCESSORIES: MANUFACTURER'S DISCONNECT AND LINESET.

3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT

BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR

PRIOR TO ORDERING EQUIPMENT.

REMARKS:

1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.

2. PROVIDE CONCRETE PAD AND ANCHOR EXTERIOR UNIT TO PAD.

3. PROVIDE CURB RAILS AND ROOF SUPPORTS FOR OUTDOOR UNIT.

4. PROVIDE THE FOLLOWING ACCESSORIES: SINGLE POINT POWER CONNECTION, DISCONNECT, HAIL GUARDS, LOW AMBIENT KIT, WIND BAFFLES.

5. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT

BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR

PRIOR TO ORDERING EQUIPMENT.

REMARKS:

1. PROVIDE MAGNAHELIC GAUGE ACROSS HOUSING FILTER.

2. PROVIDE FILTER BANK HOLDING FRAME. SUPPORT FRAME FROM STRUCTURE.

REMARKS:

1. PROVIDE DISCONNECT.

2. PROVIDE VIBRATION ISOLATION.

3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT BASED

ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING

EQUIPMENT.

REMARKS:

1. COORDINATE EXACT MODEL AND FRAME WITH CEILING / WALL TYPE.

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459

NON-SPRINKLERED

Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:5

:4

P

M

B173-M600

MECHANICAL SCHEDULES EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B173

04/15/2022 JMM GTS

16181

153 176

SPLIT SYSTEM AIR CONDITIONER - INDOOR SCHEDULE

MARK

ROOM SERVED

NOMINAL

CAPACITY

[TONS]

TOTAL COOLING

CAPACITY

[MBH]

CONDENSATE DRAIN

SIZE

INDOOR UNIT ELECTRICAL DATA

MANUFACTURER REMARKSNAME NUMBER

DIMENSIONS [IN] EAT

(DB / WB)

[°F] MODEL FLA VOLTAGE PHASE MCA DISCONNECT BY SCCRLENGTH WIDTH HEIGHT

SSIU-173-109A TR 109 2.5 30 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0301KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-173-109B TR 109 2.5 30 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0301KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SPLIT SYSTEM AIR CONDITIONER - OUTDOOR SCHEDULE

MARK

ROOM SERVED

NOMINAL

CAPACITY

[TONS]

TOTAL COOLING

CAPACITY

[MBH]

OUTDOOR UNIT ELECTRICAL DATA

MANUFACTURER REMARKSNAME NUMBER

DIMENSIONS [IN] SUMMER AMBIENT

AIR

[°F]

WINTER AMBIENT

AIR

[°F]

OPERATING

WEIGHT

[LBS] MODEL FLA VOLTAGE PHASE MCA MOCP DISCONNECT BY SCCRLENGTH WIDTH HEIGHT

SSOU-173-109A TR 109 2.5 30 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0301HA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-173-109B TR 109 2.5 30 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0301HA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

DIFFUSER, REGISTER, AND GRILLE SCHEDULE

MARK IMAGE DESCRIPTION MAX S.P. MATERIAL FINISH

FACE SIZE

NECK SIZE AIRFLOW MANUFACTURER MODEL REMARKSLENGTH WIDTH

G1 PERFORATED RETURN

GRILLE

0.10 in-wg STEEL PAINT, WHITE 24" 24" 6"x6" 8"x8"

10"x10" 12"x12" 14"x14"

0-125 126-180 181-210 211-300 301-410

TITUS

KRUEGER

PRICE

PAR

PDDR

(1)

G6 SINGLE DEFLECTION

RETURN GRILLE

0.10 in-wg STEEL PAINT, WHITE 6" 6" SEE PLAN SEE PLAN TITUS 350RL/SL (1)

FAN SCHEDULE

MARK TYPE

MAX WEIGHT

[LBS]

AIRFLOW

[CFM]

TOTAL S.P.

[IN W.C.] MAX FAN RPM MAX FAN BHP

ELECTRICAL DATA

MANUFACTURER MODEL REMARKSFLA VOLTAGE PHASE DISCONNECT BY

F-1 IN-LINE 24 100 0.54 1288 0.03 1.5 115 V 1 MECHANICAL GREENHECK CSP-A390-VG (1)(2)(3)

FILTER SCHEDULE

MARK ASSOCIATED EQUIPMENT TYPE

DEPTH

[IN] MERV RATING REMARKS

PF-1 F-1 12"x12" 2" 11 (1)(2)

A B C D E G H J K L M N P Q R SB.5

2" HWS

2" HWR

1" 1"

48x30

KEY PLAN

MAIN

ENTRY

BUILDING 174

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:0

:2

P

M

B174-M101

FIRST LEVEL FLOOR PLAN -

MECHANICAL - DEMO

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B174

04/15/2022 JMM GTS

16181

154 176

1/8" = 1'-0" F2

FIRST LEVEL FLOOR PLAN - MECHANICAL - DEMO

0 8' 16'4'

SHEET NOTES:

1. SALVAGE EXISTING TERMINAL BOX FOR RELOCATION UNDER NEW WORK.

GENERAL NOTES:

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE

ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

T H

A B C D E G H J K L M N P Q R SB.5

FREEZER

118C

FREEZER

118B

FREEZER

118A

FREEZER

118D

DOCK OFFICE

(CLERK)

FOOD STORAGE

TR

UTILITY

H.A.C.

113A

CAFETERIA

SEATING

ASSISTANT CHIEF

OFFICE

103B

CHIEF OFFICE

103A

OFFICE

H.A.C.

100A

TOILET

111C

CLERK

104K

SUPERVISOR

104J

H.A.C.

ELECTRICAL

CORRIDOR

C1-10

CORRIDOR

CI-5

CORRIDOR

C1-1

STORAGE

ELEVATOR

256 STAIR

OFFICE

MENS TOILET

124A

H.A.C.

FOOD

PRODUCTION

OFFICE

LOUNGE

CORRIDOR

CI-3

FOOD SERVICE

COORD CENTER

CORRIDOR

CI-2

NON FOOD

STORAGE

CORRIDOR

CI-12

CORRIDOR

C1-11

OFFICE

101A

SEC. WAIT

STORAGE

FREEZER

110D

INGRED CONTROL

CLERK

MENS LOCKERS

124AA

WOMEN LOCKERS

124BB

WOMENS TOILET

124B

FMS

111B

SUBSISTENCE

STORAGE

STAIR

ELEVATOR

MAIN FOOD PREP

AREA

DISH WASHING

SHIPPING AND

RECIVING

CLINIC DIET

104A

CLINIC DIET

104B

STORAGE

104C

CLINIC DIET

104D

CLINIC DIET

104E

STORAGE

104F

TOILET

104G

STORAGE

CI-6

CLOSET

104L

DINING ROOM

COOK LINE

100B

LOBBY

CI-4

CORRIDOR

CI-8

B174-M400

D1

STORAGE

COOLER

RECEIVING AREA

111A

B174-M400

D4

KEY PLAN

MAIN

ENTRY

BUILDING 174

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:0

:2

P

M

B174-M201

FIRST LEVEL FLOOR PLAN -

MECHANICAL

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B174

04/15/2022 JMM GTS

16181

155 176

1/8" = 1'-0" F2

FIRST LEVEL FLOOR PLAN - MECHANICAL

0 8' 16'4'

GENERAL NOTES:

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE

A B C D E G H J K L M N P Q R SB.5

SSOU-174-110A

SSOU-174-110B

M500

B1

KEY PLAN

MAIN

ENTRY

BUILDING 174

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:0

:2

P

M

B174-M202

ROOF LEVEL FLOOR PLAN -

MECHANICAL

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B174

04/15/2022 JMM GTS

16181

156 176

1/8" = 1'-0" F2

ROOF LEVEL PLAN - MECHANICAL

0 8' 16'4'

GENERAL NOTES:

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE

ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

ROOF OF BUILDING 174

PHOTO 01

INDICATES POINT OF VIEW OF REFERENCE PHOTO ON SHEET WITH CORRESPONDING NUMBER.##

M N

TR

CORRIDOR

C1-10

SSIU-174-110B

SSIU-174-110A

DDC

D1

D3

D7

CP-1

FDFD

10x10 SA

10x10 SA

2" HWS

2" HWR

HWR

3/4" HWR

3/4" HWS

48x30 SA

RELOCATED

TERMINAL

UNIT

M N

CORRIDOR

C1-10

SSIU-174-110BSSIU-174-110A

3/4" PC

DDC

CP-1

TR

UTILITY

ELECTRICAL

3/4" PC

V

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:0

:3

P

M

B174-M400

MECHANICAL - ENLARGED PLANS EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B174

04/15/2022 JMM GTS

16181

157 176

1/4" = 1'-0" D1

ENLARGED MECHANICAL PLAN - ROOM 110

0 2' 4'1'

SHEET NOTES:

1. BOTTOM OF NEW EQUIPMENT SHALL BE 7'-6" ABOVE FINISHED FLOOR.

2. ROUTE 3/8" REFRIGERANT LIQUID LINE AND 5/8" REFRIGERANT HOT GAS LINE FROM CONDENSING UNIT TO

CORRESPONDING DUCT-FREE SYSTEM. PIPE SIZES ARE FOR COST ESTIMATING PURPOSES, AND BASED ON

BASIS OF DESIGN MANUFACTURE AS LISTED IN THE SCHEDULE. SIZE LINES ACCORDING TO

MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL ACCESSORIES REQUIRED FOR A COMPLETE AND

OPERABLE SYSTEM.

3. ROUTE 3/4” GRAVITY CONDENSATE DRAIN LINE FROM SSIU-174-110A EAST. COMBINE WITH SSIU-174-110B CONDENSATE DRAIN LINE. CONTINUE DRAIN LINE AS SHOWN ON PLANS AND ROUTE 3/4" CONDENSATE

DRAIN TO CP-1.

4. PROVIDE WATER BUG AT FLOOR TO ALARM TO DDC WHEN ACTIVATED.

5. ROUTE 3/4" PUMPED CONDENSATE FROM CP-1 ABOVE CEILING OF UTILITY ROOM AND DROP DOWN

THROUGH CEILING AT MOP SINK. SEAL PENETRATION OF CEILING WATER TIGHT AND ROUTE CONDENSATE DOWN WALL AND DISCHARGE WITHIN TWO INCHES OF MOP SINK IN UTILITY 107 AND DISCHARGE WITH ONE

INCH AIR GAP.

6. LOCATE NEW SPRINKLERS IN SPACE TO ACCOMMODATE NEW ROOM LAYOUT. PROVIDE SPRINKLER GUARDS

ON ALL SPRINKLERS IN TR ROOM.

7. REFRIGERANT LINES UP THROUGH ROOF TO AIR COOLED CONDENSING UNIT.

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

GENERAL NOTES:

1/4" = 1'-0" D4

ENLARGED PLUMBING PLAN - ROOM 110

0 2' 4'1'

2. PROVIDE THE FOLLOWING ACCESSORIES: MANUFACTURER'S DISCONNECT AND LINESET.

3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT

BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR

PRIOR TO ORDERING EQUIPMENT.

REMARKS:

1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.

2. PROVIDE CONCRETE PAD AND ANCHOR EXTERIOR UNIT TO PAD.

3. PROVIDE CURB RAILS AND ROOF SUPPORTS FOR OUTDOOR UNIT.

4. PROVIDE THE FOLLOWING ACCESSORIES: SINGLE POINT POWER CONNECTION, DISCONNECT, HAIL GUARDS, LOW AMBIENT KIT, WIND BAFFLES.

5. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT

BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR

PRIOR TO ORDERING EQUIPMENT.

REMARKS:

1. PERFORMANCE BASED ON FLUID AND CONDITIONS INDICATED IN THIS SCHEDULE.

2. PROVIDE WITH HIGH WATER LEVEL (OVERFLOW DETECTION) SWITCH WITH TERMINAL FOR CONNECTION TO DDC

EXTERNAL ALARM.

3. PROVIDE WITH 6’, 3-CONDUCTOR CABLE WITH GROUNDED 3-PRONGE PLUG.

4. MAXIMUM 5’ OF 3/8” VINYL DISCHARGE TUBING FOR TRANSITION CONNECTION TO COPPER PUMPED CONDENSATE

PIPING.

REMARKS:

1. COORDINATE EXACT MODEL AND FRAME WITH CEILING / WALL TYPE.

2. WHEN INSTALLED IN A WALL, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE HORIZONTAL (PARALLEL TO THE

FLOOR). WHEN INSTALLED IN A CEILING, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE PARALLEL TO THE LONG

DIMENSION OF THE GRILLE.

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:0

:3

P

M

B174-M600

MECHANICAL SCHEDULES EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B174

04/15/2022 JMM GTS

16181

158 176

SPLIT SYSTEM AIR CONDITIONER - INDOOR SCHEDULE

MARK

ROOM SERVED

NOMINAL

CAPACITY

[TONS]

TOTAL COOLING

CAPACITY

[MBH]

CONDENSATE DRAIN

SIZE

INDOOR UNIT ELECTRICAL DATA

MANUFACTURER REMARKSNAME NUMBER

DIMENSIONS [IN] EAT

(DB / WB)

[°F] MODEL FLA VOLTAGE PHASE MCA DISCONNECT BY SCCRLENGTH WIDTH HEIGHT

SSIU-174-110A TR 110 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SSIU-174-110B TR 110 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)

SPLIT SYSTEM AIR CONDITIONER - OUTDOOR SCHEDULE

MARK

ROOM SERVED

NOMINAL

CAPACITY

[TONS]

TOTAL COOLING

CAPACITY

[MBH]

OUTDOOR UNIT ELECTRICAL DATA

MANUFACTURER REMARKSNAME NUMBER

DIMENSIONS [IN] SUMMER AMBIENT

AIR

[°F]

WINTER AMBIENT

AIR

[°F]

OPERATING

WEIGHT

[LBS] MODEL FLA VOLTAGE PHASE MCA MOCP DISCONNECT BY SCCRLENGTH WIDTH HEIGHT

SSOU-174-110A TR 110 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

SSOU-174-110B TR 110 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)

PUMP SCHEDULE

MARK

FLOW

[GPH]

TOTAL HEAD

[FT]

SHUT-OFF HEAD

[FT]

SUCTION /

DISCHARGE SIZE

[IN]

ELECTRICAL DATA

MANUFACTURER MODEL REMARKSHP FLA VOLTAGE

CP-1 10 20 21 3/8" 0.033 1.5 115 V LITTLE GIANT VCMX-20ULS (1)(2)(3)(4)

DIFFUSER, REGISTER, AND GRILLE SCHEDULE

MARK IMAGE DESCRIPTION MAX S.P. MATERIAL FINISH

FACE SIZE

NECK SIZE AIRFLOW MANUFACTURER MODEL REMARKSLENGTH WIDTH

D3 PLAQUE FACE STYLE

SUPPLY DIFFUSER

0.10 in-wg STEEL PAINT, WHITE 12" 12" 6" 8"

0-140 141-210

TITUS

KRUEGER

PRICE

OMNI

PLQ

SPD

(1)

D7 DOUBLE DEFLECTION

SUPPLY GRILLE

0.10 in-wg STEEL PAINT, WHITE SEE PLAN SEE PLAN SEE PLAN SEE PLAN TITUS

KRUEGER

PRICE

300RL/SL

(1)(2)

EPO EPO

EPO

A B C

STAIR

#1

GENERATION

ROOM

MAIN ELECTRICAL

ROOM

1 1

KEY PLAN

MAIN

ENTRY

BUILDING 175

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:0

:5

A

M

B175-M101

FIRST LEVEL FLOOR PLAN -

MECHANICAL - DEMO

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B175

04/15/2022 JMM GTS

16181

159 176

0 8' 16'4'

GENERAL NOTES:

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

1/8" = 1'-0" E4

FIRST LEVEL FLOOR PLAN - MECHANICAL - DEMO

PHOTO 01

SHEET NOTES:

1. REMOVE EXISTING LOUVER BLANK OFF PANELS.

E

E

EPO EPO

EPO EPO

E

A B C

STAIR

#1

GENERATION

ROOM

MAIN ELECTRICAL

ROOM

D-3

D-1

D-2

INTAKE

EXHAUST

6 EA UP

KEY PLAN

MAIN

ENTRY

BUILDING 175

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:0

:5

A

M

B175-M201

FIRST LEVEL FLOOR PLAN -

MECHANICAL

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B175

04/15/2022 JMM GTS

16181

160 176

0 8' 16'4'

SHEET NOTES:

1. PROVIDE 12'X12' INTAKE DAMPER. REFER TO PHOTO FOR EXAMPLE OF EXISTING.

2. 12'-0"x12'-0"x1'-0" DOUBLE WALL, INSULATED SHEET METAL PLENUM.

3. 12'-0"x12'-0"x1'-1" DOUBLE WALL, INSULATED SHEET METAL PLENUM. CONNECT TO GENERATOR RADIATOR.

4. PROVIDE 2'-0"x7'-0" BYPASS DAMPER.

5. EMERGENCY GENERATOR EXHAUST MUFFLER WITH 12" INCH INLET AND 12" INCH OUTLET. ROUTE 12" INCH

PIPE INLET TO GENERATOR AND REDUCE AT GENERATOR AS NECESSARY TO CONNECT TO GENERATOR FLEXT CONNECTION. DISCHARGE 12" INCH STEEL PIPE DISCHARGE THROUGH ROOF AS INDICATED. REFER

TO SPECIFICATION 263213 FOR PERFORMANCE AND CONSTRUCTION REQUIREMENTS.

6. 12" GENERATOR EXHAUST UP THROUGH ROOF. LOCATION IS APPROXIMATE. REFER TO PHOTO 01 THIS

SHEET FOR SIMILAR MUFFLER INSTALLTION.

GENERAL NOTES:

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

1/8" = 1'-0" E4

FIRST LEVEL FLOOR PLAN - MECHANICAL

PHOTO 01

A B C

EA DN

KEY PLAN

MAIN

ENTRY

BUILDING 175

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:0

:5

A

M

B175-M202

ROOF LEVEL FLOOR PLAN -

MECHANICAL

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B175

04/15/2022 JMM GTS

16181

161 176

0 8' 16'4'

GENERAL NOTES:

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

1/8" = 1'-0" E4

ROOF LEVEL PLAN - MECHANICAL

E A

A

A R

E A

C

A R

E A

B

A R

E A

D

A R

E A

A

A R

E A

C

AREA C

A R

E A

B

A R

E A

D

AREA D

AREA A

AREA B

15.1

B1

B2

B3 B4

B5 B6

B7

B8

B7.1

B4.1

BA

BB

BC

BD

BD.1

A1

A2

A3

A4

A5

AA AB

AC

AD

AE

AF AG

AH

CA

CB

CC

CD

CE

CF

CG

CH

0.10.2

0.7

J.2J.1

A

B C

D

E

F

G H G.1

F.1E.2E.1

C.1A.2

J

D1

D2 D3

D4

D5 D6

D7

D8

D8.1

D8.2

DA

DB

DC

DD

DD.1

C1

C2

C3

C4

C5

KEY PLAN

MAIN

ENTRY

BUILDING 185

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:1

:2

P

M

B185-M101

FIRST LEVEL FLOOR PLAN -

OVERALL - MECHANICAL DEMO

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B185

04/15/2022 JMM GTS

16181

162 176

1/16" = 1'-0" F3

FIRST LEVEL FLOOR PLAN - MECHANICAL - DEMO - OVERALL*

0 16' 32'8'

E A

B

A R

E A

D

A R

E A

A

A R

E A

C

AREA C

A R

E A

B

A R

E A

D

AREA D

0.7 J.2J.1F G H G.1F.1E.2E.1 J

D1

D2

D3

D4

D5

D6

D7

D8

D8.1

D8.2

DA

DB

DC

DDDD.1

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:1

:2

P

M

B185-M101-D

FIRST LEVEL FLOOR PLAN - AREA

D - MECHANICAL DEMO

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B185

04/15/2022 JMM GTS

16181

163 176

1/8" = 1'-0"F3

FIRST LEVEL FLOOR PLAN - AREA D - MECHANICAL - DEMO

0 8' 16'4'

SHEET NOTES:

1. SALVAGE EXISTING TERMINAL AIR BOX AND RELOCATE AS SHOWN ON NEW WORK PLAN B185-F101D.

2. DEMOLISH EXISTING ROOM SPRINKLER HEADS. DEMOLISH EXISTING SPRINKLER PIPING AS NECESSARY TO

ACCOMMODATE NEW WORK PLAN.

GENERAL NOTES:

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.

E A

A

A R

E A

C

A R

E A

B

A R

E A

D

A R

E A

A

A R

E A

C

AREA C

A R

E A

B

A R

E A

D AREA D

AREA A

AREA B

15.1

B1

B2

B3 B4

B5 B6

B7

B8

B7.1

B4.1

BA

BB

BC

BD

BD.1

A1

A2

A3

A4

A5

AA AB

AC

AD

AE

AF AG

AH

CA

CB

CC

CD

CE

CF

CG

CH

0.10.2

0.7

J.2J.1

A

B C

D

E

F

G H G.1

F.1E.2E.1

C.1A.2

J

D1

D2 D3

D4

D5 D6

D7

D8

D8.1

D8.2

DA

DB

DC

DD

DD.1

C1

C2

C3

C4

C5

KEY PLAN

MAIN

ENTRY

BUILDING 185

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:1

:2

P

M

B185-M102

SECOND LEVEL FLOOR PLAN -

OVERALL - MECHANICAL DEMO

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B185

04/15/2022 JMM GTS

16181

164 176

1/16" = 1'-0" F3

SECOND LEVEL FLOOR PLAN - MECHANICAL - DEMO - OVERALL*

0 8' 16'4'

E A

B

A R

E A

D

A R

E A

A

A R

E A

C

AREA C

A R

E A

B

A R

E A

D

AREA D

0.7 J.2J.1F G H G.1F.1E.2E.1 J

D1

D2

D3

D4

D5

D6

D7

D8

D8.1

D8.2

DA

DB

DC

DDDD.1

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES PROJECT #

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

20459 Sheet of

04/15/2022

B

IM

/2

V

A M a ri o n E

H R

M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6

-7

.B

.T

R

.r v t

/1

/2

:1

:3

P

M

B185-M102-D

SECOND LEVEL FLOOR PLAN -

AREA D - MECHANICAL DEMO

EHRM INFRASTRUCTURE

UPGRADES, MARION, IN

MARION, IN

610-21-701

B185

04/15/2022 JMM GTS

16181

165 176

1/8" = 1'-0"F3

SECOND LEVEL FLOOR PLAN - AREA D - MECHANICAL - DEMO

0 8' 16'4'

SHEET NOTES:

1. SALVAGE EXISTING TERMINAL AIR BOX AND RELOCATE AS SHOWN ON NEW WORK PLAN B185-F201-D.

2. DEMOLISH EXISTING ROOM SPRINKLER HEADS. DEMOLISH EXISTING SPRINKLER PIPING AS NECESSARY TO

ACCOMMODATE NEW WORK PLAN.

GENERAL NOTES:

1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR

DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR

R

E A

A

A R

E A

C

A R

E A

B

A R

E A

D

A R

E A

A

A R

E A

C

AREA C

A R

E A

B

A R

E A

D AREA D

AREA A

AREA B

15.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .