This federal contract opportunity solicitation involves infrastructure upgrades and renovations to existing spaces at the Marion VA facility. The solicitation seeks contractors to perform electrical, HVAC, communication, physical security, and fiber infrastructure upgrades campus wide within and between buildings. Additional requirements include modifying impacted roads, walks, grading and drainage, updating other existing utilities and the WAN, as well as hazardous material abatement. The soliciting agency is the Department of Veterans Affairs Technology Acquisition Center located in Austin.
View the file
Other files for this federal contract opportunity
Show all 42
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REMARKS:
1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.
2. PROVIDE THE FOLLOWING ACCESSORIES: MANUFACTURER'S DISCONNECT AND LINESET.
3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT
BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR
PRIOR TO ORDERING EQUIPMENT.
REMARKS:
1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.
2. PROVIDE CONCRETE PAD AND ANCHOR EXTERIOR UNIT TO PAD.
3. PROVIDE CURB RAILS AND ROOF SUPPORTS FOR OUTDOOR UNIT.
4. PROVIDE THE FOLLOWING ACCESSORIES: SINGLE POINT POWER CONNECTION, DISCONNECT, HAIL GUARDS, LOW AMBIENT KIT, WIND BAFFLES.
5. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT
BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR
PRIOR TO ORDERING EQUIPMENT.
REMARKS:
1. PROVIDE WITH WINDOW INSTALLATION KIT.
REMARKS:
1. PROVIDE DISCONNECT.
2. PROVIDE VIBRATION ISOLATION.
3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS.
EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING EQUIPMENT.
REMARKS:
1. PROVIDE MAGNAHELIC GAUGE ACROSS HOUSING FILTER.
2. PROVIDE FILTER BANK HOLDING FRAME. SUPPORT FRAME FROM STRUCTURE.
REMARKS:
1. PROVIDE WITH INTEGRAL CONDENSATE COOLER, BLOWER PACK.
REMARKS:
1. COORDINATE EXACT MODEL AND FRAME WITH CEILING / WALL TYPE.
REMARKS:
1. PERFORMANCE BASED ON FLUID AND CONDITIONS INDICATED IN THIS SCHEDULE.
2. PROVIDE WITH HIGH WATER LEVEL (OVERFLOW DETECTION) SWITCH WITH TERMINAL FOR CONNECTION TO DDC
EXTERNAL ALARM.
3. PROVIDE WITH BRASS CHECK VALVES.
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459
NON-SPRINKLERED
Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
B124-M600
MECHANICAL SCHEDULES EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B124
04/15/2022 JMM GTS
16181
80 176
SPLIT SYSTEM AIR CONDITIONER - INDOOR SCHEDULE
MARK
ROOM SERVED
NOMINAL
CAPACITY
[TONS]
TOTAL COOLING
CAPACITY
[MBH]
CONDENSATE DRAIN
SIZE
INDOOR UNIT ELECTRICAL DATA
MANUFACTURER REMARKSNAME NUMBER
DIMENSIONS [IN] EAT
(DB / WB)
[°F] MODEL FLA VOLTAGE PHASE MCA DISCONNECT BY SCCRLENGTH WIDTH HEIGHT
SSIU-124-136A TR 136 2.5 30 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0301KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-124-136B TR 136 3.0 30 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0301KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-124-217A TR 217 3.0 30 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0301KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-124-217B TR 217 3.0 30 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0301KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-124-314A TR 314 3.0 30 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0301KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-124-314B TR 314 3.0 30 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0301KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SPLIT SYSTEM AIR CONDITIONER - OUTDOOR SCHEDULE
MARK
ROOM SERVED
NOMINAL
CAPACITY
[TONS]
TOTAL COOLING
CAPACITY
[MBH]
OUTDOOR UNIT ELECTRICAL DATA
MANUFACTURER REMARKSNAME NUMBER
DIMENSIONS [IN] SUMMER AMBIENT
AIR
[°F]
WINTER AMBIENT
AIR
[°F]
OPERATING
WEIGHT
[LBS] MODEL FLA VOLTAGE PHASE MCA MOCP DISCONNECT BY SCCRLENGTH WIDTH HEIGHT
SSOU-124-136A TR 136 2.5 30 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0301KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-124-136B TR 136 2.5 30 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0301KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-124-217A TR 217 2.5 30 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0301KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-124-217B TR 217 2.5 30 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0301KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-124-314A TR 314 2.5 30 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0301KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-124-314B TR 314 2.5 30 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0301KA70NA 7.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
WINDOW AIR CONDITIONER SCHEDULE
MARK SERVES NOMINAL TONS
DIMENSIONS [IN] AMBIENT TEMPERATURE
(SUMMER )
[°F]
TOTAL COOLING
CAPACITY
[MBH]
ELECTRICAL DATA
MODEL MANUFACTURER REMARKSLENGTH WIDTH HEIGHT VOLTAGE PHASE
AC-1 BREAK ROOM 341 1.25 29" 26" 18" 90 15 115 V 1 LW1521ERSM LG (1)
DIFFUSER, REGISTER, AND GRILLE SCHEDULE
MARK IMAGE DESCRIPTION MAX S.P. MATERIAL FINISH
FACE SIZE
NECK SIZE AIRFLOW MANUFACTURER MODEL REMARKSLENGTH WIDTH
G1 PERFORATED RETURN
GRILLE
0.10 in-wg STEEL PAINT, WHITE 24" 24" 6"x6" 8"x8"
10"x10" 12"x12" 14"x14"
0-125 126-180 181-210 211-300 301-410
TITUS
KRUEGER
PRICE
PAR
PDDR
(1)
G6 SINGLE DEFLECTION
RETURN GRILLE
0.10 in-wg STEEL PAINT, WHITE 6" 6" SEE PLAN SEE PLAN TITUS 350RL/SL (1)
FAN SCHEDULE
MARK TYPE
MAX WEIGHT
[LBS]
AIRFLOW
[CFM]
TOTAL S.P.
[IN W.C.] MAX FAN RPM MAX FAN BHP
ELECTRICAL DATA
MANUFACTURER MODEL REMARKSFLA VOLTAGE PHASE DISCONNECT BY
F-1 IN-LINE 24 100 0.54 1288 0.03 1.5 115 V 1 MECHANICAL GREENHECK CSP-A390-VG (1)(2)
F-2 IN-LINE 24 100 0.54 1288 0.03 1.5 115 V 1 MECHANICAL GREENHECK CSP-A390-VG (1)(2)
F-3 IN-LINE 24 100 0.54 1288 0.03 1.5 115 V 1 MECHANICAL GREENHECK CSP-A390-VG (1)(2)
FILTER SCHEDULE
MARK ASSOCIATED EQUIPMENT TYPE
DEPTH
[IN] MERV RATING REMARKS
PF-1 F-1 12"x12" 2" 11 (1)(2)
PF-2 F-2 12"x12" 2" 11 (1)(2)
PF-3 F-3 12"x12" 2" 11 (1)(2)
ELECTRODE STEAM HUMIDIFIER SCHEDULE
MARK SERVICE
MAKE UP WATER
CONNECTION SIZE
WATER PIPING ELECTRICAL DATA
MANUFACTURER MODEL REMARKS
CAPACITY
[LB / HR]
DRAIN PIPE CONNECTION
SIZE KW VOLTAGE PHASE
H-1 TR 314 1/2" 5.6 3/4" 1.9 120 V 1 DRISTEEM XRT (1)
H-2 TR 314 1/2" 5.6 3/4" 1.9 120 V 1 DRISTEEM XRT (1)
H-3 TR 314 1/2" 5.6 3/4" 1.9 120 V 1 DRISTEEM XRT (1)
PUMP SCHEDULE
MARK
FLOW
[GPH]
TOTAL HEAD
[FT]
SHUT-OFF HEAD
[FT]
SUCTION /
DISCHARGE SIZE
[IN]
ELECTRICAL DATA
MANUFACTURER MODEL REMARKSHP FLA VOLTAGE
CP-1 200 20 32 3/8" 0.125 1.4 115 V LITTLE GIANT HT-VCL-30-P (1)(2)(3)
Revisions: Date:
UPS ROOM
100A
CLOSET
101B
PHONE ROOM
ELEC/UPS
ENTRANCE
FACILITY
2" F
1/
4" F
1"
1"
1"
KEY PLAN
MAIN
ENTRY
BUILDING 127
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:5
P
M
B127-F201
FIRST LEVEL FLOOR PLAN - FIRE
PROTECTION
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B127
04/15/2022 JLK SSK
16181
81 176
1/4" = 1'-0" F4
FIRST LEVEL FLOOR PLAN - FIRE PROTECTION
0 2' 4'1'
SHEET NOTES:
1. 2" FIRE PROTECTION PIPING FROM BUILDING 15. SEE SHEET B15-F201 FOR CONTINUATION.
2. PROVIDE CLEAN AGENT FIRE PROTECTION SYSTEM TO SERVE ENTRANCE FACILITY. ENTRANCE FACILITY IS
275 SQ FT. PROVIDE ONE CYLINDER, CONTROL PANEL, AND ASSOCIATED PIPING TO FEED ENTRANCE
FACILITY.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.
KEY PLAN
MAIN
ENTRY
BUILDING 127
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:5
P
M
B127-M101
FIRST LEVEL FLOOR PLAN -
MECHANICAL DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B127
04/15/2022 JMM GTS
16181
82 176
1/4" = 1'-0" F4
FIRST LEVEL FLOOR PLAN - MECHANICAL - DEMO
0 2' 4'1'
SHEET NOTES:
1. DEMOLISH ABOVE CEILING FAN COIL UNIT, ASSOCIATED DUCTWORK, ROOF MOUNTED CONDENSING UNIT
AND PIPING SERVING EXISTING COMM ROOM 102. PATCH ALL PENETRATIONS TO MATCH EXISTING
CONSTRUCTION AND ROOF WARRANTIES.
2. DEMOLISH ALL PLUMBING SUPPLY, VENT AND WASTE PIPING BACK TO CONNECTION TO MAINS.
3. DEMOLISH ALL ABOVE CEILING DUCTWORK BACK TO CONNECTIONS TO MAINS OUTSIDE OF ROOM.
4. DEMOLISH EXISTING ROOM SPRINKLER HEADS.
5. DEMOLISH THE EXISTING COOLING UNITS, ASSOCIATED DUCTWORK, EXTERIOR CONDENSING AND PIPING
SERVING THE EXISTING OFFICE SPACE AND HALLWAY. REPAIR ROOFING WHERE EXISTING ROOFTOP UNITS
AND PIPE PENETRATIONS ARE REMOVED.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.
CR AC
UPS ROOM
100A
CLOSET
101B
PHONE ROOM
ELEC/UPS
ENTRANCE
FACILITY
SSIU-127-102B SSIU-127-102C
1 1
SSIU-127-101C
SSIU-127-101B
SSIU-127-101A
SSIU-127-102A
G1
14"x14"
D2
8"x8"
D2
6"x6"
D2
6"x6"
D2
6"x6"
D2
6"x6"
D2
6"x6"
8"x8"
GE7
EF-1 ON
ROOF ABOVE
8x8 EA
12x12 RA 12x12 SA
10x8 SA
200 CFM SIDEWALL
SUPPLY. REFER TO
BUILDING 15.SF-1
FSFS
FSFS
PF-1
H-2
H-1
CP-1
CP-2
3/4" PC
3/4" CD
3/4" CD
121212
3/4" PC
13 13
1" PC
8x8 SA
6x6 SA
3/4" CD
3/4" CD
1" CD
M501
D1
M501
D1
1/2"
1" CD
KEY PLAN
MAIN
ENTRY
BUILDING 127
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:0
P
M
B127-M201
FIRST LEVEL FLOOR PLAN -
MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B127
04/15/2022 JMM GTS
16181
83 176
1/4" = 1'-0" F4
FIRST LEVEL FLOOR PLAN - MECHANICAL
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.
SHEET NOTES:
1. REFRIGERANT LINES UP TO CONDENSING UNITS ON ROOF.
2. ROUTE CONDENSATE FROM UNIT TO COMMON CONDENSATE DRAIN LINE AS SHOWN.
3. LOCATE NEW SPRINKLERS IN SPACE TO ACCOMMODATE NEW ROOM LAYOUT.
4. LOCATE CONDENSERS FOR ROOM COOLING UNITS ON ROOF ABOVE. SEE PHOTO FOR LOCATION
COORDINATION. MOUNT ON ROOF PER DETAIL B1 ON SHEET M500.
5. PROVIDE UPDATED SPRINKLER LAYOUT COORDINATED WITH NEW EQUIPMENT AND WALL REVISIONS.
6. ROUTE PUMPED CONDENSATE TO FLOOR DRAIN APPROXIMATELY IN THIS LOCATION. DO NOT ROUTE DRAIN
OVER EXISTING ELECTRICAL EQUIPMENT.
7. MOUNT FROM CEILING WITH UNISTRUT.
8. CONDENSING UNITS MAY BE LOCATED IN SPACES VACATED BY EXISTING EQUIPMENT TO BE DEMOLISHED.
PROVIDE MANUFACTURERS RECOMMENDED CLEARANCES FROM ADJACENT WALLS AND OTHER PIECES OF
EQUIPMENT.
9. PROVIDE WATER BUG AT FLOOR TO ALARM TO DDC WHEN ACTIVATED.
10. PROVIDE FILTER RACK UPSTREAM OF SUPPLY FAN SF-1. PROVIDE TRANSITION DUCT FROM PRE-FILTER TO
FAN INLET.
11. EXTEND NEW DOMESTIC COLD WATER LINE FROM EXISTING WATER LINE AT DEMOLISHED SINK TO SERVE
BACKFLOW PREVENTER FOR HUMIDIFIER MAKE-UP WATER.
12. BOTTOM OF COOLING UNIT SHALL BE A MINIMUM OF 7-0” A.F.F. ADJUST MOUNTING HEIGHT TO AVOID
CONFLICTS WITH CABLE TRAY. MAINTAIN MANUFACTURERS SERVICE CLEARANCE RECOMMENDATIONS.
13. ROUTE 3/8" REFRIGERANT LIQUID LINE AND 5/8" REFRIGERANT HOT GAS LINE FROM CONDENSING UNIT TO
CORRESPONDING DUCT-FREE SYSTEM. PIPE SIZES ARE FOR COST ESTIMATING PURPOSES, AND BASED ON
BASIS OF DESIGN MANUFACTURE AS LISTED IN THE SCHEDULE. SIZE LINES ACCORDING TO
MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL ACCESSORIES REQUIRED FOR A COMPLETE AND
OPERABLE SYSTEM.
14. DISCHARGE 3/4" PUMPED CONDENSATE INTO TOP OF 1" PUMPED CONDENSATE LINE.
15. PUMPED CONDENSATE SHALL SLOPE TOWARDS DISCHARGE.
16. CONDENSATE PUMP LOCATED ON FLOOR BELOW HUMIDIFIER. DISCHARGE ALL ENTRANCE FACILITY 102
COOLING CONDENSATE DRAINS INTO A COMMON GRAVITY HEADER AND COMBINE WITH HUMIDIFIER-1 & 2 DRAIN AND ASSOCIATED RO DRAINS AND ROUTE TO CONDENSATE PUMP. PROVIDE DRAIN PAN UNDER
CONDENSATE PIPING WITHIN ROOM 102 WITH WATER BUG ALARM TO DDC.
17. CONDENSATE PUMP LOCATED ON FLOOR BELOW COOLING UNIT AND COLLECTS GRAVITY CONDENSATE
FROM SSIU-127-101A, SSIU-127-101B, AND SSIU-127-101C.
18. PROVIDE 1/2" NON-POTABLE WATER TO HUMIDIFIER AND RO SYSTEM. PROVIDE DRAIN PAN UNDER PIPING
WITHIN ENTRANCE FACILITY 102 WITH WATER BUG ALARM TO DDC.
19. PROVIDE 1/2" NON-POTABLE WATER TO HUMIDIFIER AND RO SYSTEM FROM BACKFLOW PREVENTER.
20. PROVIDE REDUCED PRESSURE ZONE BACKFLOW PREVENTER ON WALL AND ROUTE 1/2" DOMESTIC COLD
WATER TO BACKFLOW PREVENTER.
21. ROUTE BACKFLOW PREVENTER DRAIN LINE TO FLOOR DRAIN APPROXIMATELY IN THIS LOCATION. DO NOT
ROUTE DRAIN OVER EXISTING ELECTRICAL EQUIPMENT.
22. MAINTAIN HUMIDIFIER MANUFACTURERS REQUIRED “NON-WETTING” CLEARANCES FROM
HUMIDIFIER. COORDINATE WITH OTHER TRADES TO ENSURE NO SOLID SURFACES OR OBJECTS ARE
LOCATED WITHIN THE MANUFACTURES “NON-WETTING” DISTANCES.
GENERAL NOTES:
0 2' 4'1'
CLOUDED AREAS ARE
ACCEPTABLE LOCATIONS
FOR CONDENSING UNITS.
PHOTO 01
REMARKS:
1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.
2. PROVIDE THE FOLLOWING ACCESSORIES: MANUFACTURER'S DISCONNECT AND LINESET.
3. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT
BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR
PRIOR TO ORDERING EQUIPMENT.
REMARKS:
1. PERFORMANCE BASED ON CONDITIONS INDICATED IN THIS SCHEDULE.
2. PROVIDE CONCRETE PAD AND ANCHOR EXTERIOR UNIT TO PAD.
3. PROVIDE CURB RAILS AND ROOF SUPPORTS FOR OUTDOOR UNIT.
4. PROVIDE THE FOLLOWING ACCESSORIES: SINGLE POINT POWER CONNECTION, DISCONNECT, HAIL GUARDS, LOW AMBIENT KIT, WIND BAFFLES.
5. "SCCR" - VALUE INDICATED IS AVAILABLE SHORT CIRCUIT CURRENT (SCC) IN KILOAMPS AT THE EQUIPMENT
BASED ON PRELIMINARY DESIGN PHASE CALCULATIONS. EQUIPMENT SCCR SHALL BE MINIMUM 120% OF THE AVAILABLE SCC. RATING SHALL BE ADJUSTED IF REQUIRED BASED ON FINAL SCC CALCULATION. EQUIPMENT INDICATED WITH 5 KA MAY BE PROVIDED WITH 5 KA SCCR. REVIEW SCCR WITH ELECTRICAL CONTRACTOR
PRIOR TO ORDERING EQUIPMENT.
REMARKS:
1. PROVIDE DISCONNECT.
2. PROVIDE VIBRATION ISOLATION.
3. PROVIDE WITH 18" ROOF CURB.
4. PROVIDE AUTOMATIC BACKDRAFT DAMPER INTERLOCKED WITH MOTOR.
REMARKS:
1. PROVIDE FILTER BANK HOLDING FRAME. SUPPORT FRAME FROM STRUCTURE.
2. PROVIDE 24" x 12" FILTER.
REMARKS:
1. PROVIDE WITH INTEGRAL CONDENSATE COOLER, BLOWER PACK.
REMARKS:
1. PERFORMANCE BASED ON FLUID AND CONDITIONS INDICATED IN THIS SCHEDULE.
2. PROVIDE WITH HIGH WATER LEVEL (OVERFLOW DETECTION) SWITCH WITH TERMINAL FOR CONNECTION TO DDC
EXTERNAL ALARM.
3. PROVIDE WITH 6’, 3-CONDUCTOR CABLE WITH GROUNDED 3-PRONGE PLUG.
4. MAXIMUM 5’ OF 3/8” VINYL DISCHARGE TUBING FOR TRANSITION CONNECTION TO COPPER PUMPED CONDENSATE
PIPING.
5. PROVIDE WITH BRASS CHECK VALVE.
REMARKS:
1. COORDINATE EXACT MODEL AND FRAME WITH CEILING / WALL TYPE.
2. WHEN INSTALLED IN A WALL, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE HORIZONTAL (PARALLEL TO THE
FLOOR). WHEN INSTALLED IN A CEILING, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE PARALLEL TO THE LONG
DIMENSION OF THE GRILLE.
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:0
:0
P
M
B127-M600
MECHANICAL SCHEDULES EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B127
04/15/2022 JMM GTS
16181
84 176
SPLIT SYSTEM AIR CONDITIONER - INDOOR SCHEDULE
MARK
ROOM SERVED
NOMINAL
CAPACITY
[TONS]
TOTAL COOLING
CAPACITY
[MBH]
CONDENSATE DRAIN
SIZE
INDOOR UNIT ELECTRICAL DATA
MANUFACTURER REMARKSNAME NUMBER
DIMENSIONS [IN] EAT
(DB / WB)
[°F] MODEL FLA VOLTAGE PHASE MCA DISCONNECT BY SCCRLENGTH WIDTH HEIGHT
SSIU-127-101A ELEC/UPS 101 2.5 30 3/4" 46 1/16" 11 5/8" 14 3/8" 90/72 PKA-A30KA7 0.36 208 V 1 1 MANUFACTURER 5 MITSUBISHI ELECTRIC (1)(2)(3)
SSIU-127-101B ELEC/UPS 101 2.5 30 3/4" 46 1/16" 11 5/8" 14 3/8" 90/72 PKA-A30KA7 0.36 208 V 1 1 MANUFACTURER 5 MITSUBISHI ELECTRIC (1)(2)(3)
SSIU-127-101C ELEC/UPS 101 2.5 30 3/4" 46 1/16" 11 5/8" 14 3/8" 90/72 PKA-A30KA7 0.36 208 V 1 1 MANUFACTURER 5 MITSUBISHI ELECTRIC (1)(2)(3)
SSIU-127-102A ENTRANCE FACILITY 102 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-127-102B ENTRANCE FACILITY 102 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SSIU-127-102C ENTRANCE FACILITY 102 2.0 24 3/4" 46 1/16" 11 5/8" 14 3/8" 80/67 TPKA0A0241KA70A 0.36 208 V 1 1 MANUFACTURER 5 TRANE (1)(2)(3)
SPLIT SYSTEM AIR CONDITIONER - OUTDOOR SCHEDULE
MARK
ROOM SERVED
NOMINAL
CAPACITY
[TONS]
TOTAL COOLING
CAPACITY
[MBH]
OUTDOOR UNIT ELECTRICAL DATA
MANUFACTURER REMARKSNAME NUMBER
DIMENSIONS [IN] SUMMER AMBIENT
AIR
[°F]
WINTER AMBIENT
AIR
[°F]
OPERATING
WEIGHT
[LBS] MODEL FLA VOLTAGE PHASE MCA MOCP DISCONNECT BY SCCRLENGTH WIDTH HEIGHT
SSOU-127-101A ELEC/UPS 101 2.5 30 37 7/16" 13 3/16" 37 1/8" 115 -40 151 PUY-A30NHA7 0.4 208 V 1 19 26 ELEC 5 MITSUBISHI ELECTRIC (1)(2)(3)(4)(5)
SSOU-127-101B ELEC/UPS 101 2.5 30 37 7/16" 13 3/16" 37 1/8" 115 -40 151 PUY-A30NHA7 0.4 208 V 1 19 26 ELEC 5 MITSUBISHI ELECTRIC (1)(2)(3)(4)(5)
SSOU-127-101C ELEC/UPS 101 2.5 30 37 7/16" 13 3/16" 37 1/8" 115 -40 151 PUY-A30NHA7 0.4 208 V 1 19 26 ELEC 5 MITSUBISHI ELECTRIC (1)(2)(3)(4)(5)
SSOU-127-102-A ENTRANCE FACILITY 102 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241HA70NA 11.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-127-102-B ENTRANCE FACILITY 102 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241HA70NA 11.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
SSOU-127-102-C ENTRANCE FACILITY 102 2.0 24 38" 13 3/8" 38" 95 / 75 -10 151 TRUYA0241HA70NA 11.4 208 V 1 19 26 ELEC 5 TRANE (1)(2)(3)(4)(5)
FAN SCHEDULE
MARK TYPE
AIRFLOW
[CFM]
DUCT CONNECTION SIZE
[IN]
TOTAL S.P.
[IN W.C.] MAX FAN RPM MAX FAN BHP
ELECTRICAL DATA
MANUFACTURER MODEL REMARKSHP VOLTAGE PHASE
SF-1 INLINE 700 18 x 18 0.75 1,393 0.19 0.5 115 V 1 GREENHECK SQ-130HP-VG (1)(2)
EF-1 DOWNBLAST 200 8 x 8 0.38 1,589 0.03 0.1 115 V 1 GREENHECK G-070-VG (3)(4)
FILTER SCHEDULE
MARK ASSOCIATED EQUIPMENT FUNCTION TYPE
DEPTH
[IN] MERV RATING REMARKS
PF-1 SF-1 PREFILTER PLEATED 2 8 (1)(2)
ELECTRODE STEAM HUMIDIFIER SCHEDULE
MARK SERVICE
MAKE UP WATER
CONNECTION SIZE
WATER PIPING ELECTRICAL DATA
MANUFACTURER MODEL REMARKS
CAPACITY
[GAL / HR]
DRAIN PIPE CONNECTION
SIZE KW VOLTAGE PHASE
H-1 ENTRANCE FACILITY 102 1/2" 5.6 3/4" 1.9 120 V 1 DRISTEEM XTR (1)
H-2 ELEC/UPS 101 1/2" 5.6 3/4" 1.9 120 V 1 DRISTEEM XTR (1)
PUMP SCHEDULE
MARK
FLOW
[GPH]
TOTAL HEAD
[FT]
SHUT-OFF HEAD
[FT]
SUCTION /
DISCHARGE SIZE
[IN]
ELECTRICAL DATA
MANUFACTURER MODEL REMARKSHP FLA VOLTAGE
CP-1 200 20 32 3/8" 0.125 1.4 115 V LITTLE GIANT HT-VCL-30-P (1)(2)(5)
CP-2 10 20 21 3/8" 0.033 1.5 115 V LITTLE GIANT VCMX-20ULS (1)(2)(3)(4)
DIFFUSER, REGISTER, AND GRILLE SCHEDULE add remarks
MARK IMAGE DESCRIPTION MAX S.P. MATERIAL FINISH
FACE SIZE
NECK SIZE AIRFLOW MANUFACTURER MODEL REMARKSLENGTH WIDTH
D2 DOUBLE DEFLECTION
SUPPLY GRILLE
0.10 in-wg STEEL PAINT, WHITE SEE PLAN SEE PLAN SEE PLAN SEE PLAN TITUS
KRUEGER
PRICE
300RL/SL
(1)(2)
G1 SINGLE DEFLECTION
RETURN GRILLE
0.10 in-wg STEEL PAINT, WHITE SEE PLAN SEE PLAN SEE PLAN SEE PLAN TITUS
KRUEGER
PRICE
350RL/SL
S80
(1)
GE7 SINGLE DEFLECTION
RETURN GRILLE
0.10 in-wg STEEL PAINT, WHITE SEE PLAN SEE PLAN SEE PLAN SEE PLAN TITUS
KRUEGER
PRICE
350RL/SL
S80
(1)
A R
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
A R
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
TU R 27 28 29
23m
24s
25s 25 2626s
22 23s
191817161515s
13 14
14s13s
10KL
MNOPQS
5s 6 6s 7m
7s
J
Jw
Cm
2 3
4 4s
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
KEY PLAN
MAIN
ENTRY
BUILDING 138
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:0
P
M
B138-M100
BASEMENT LEVEL FLOOR PLAN -
OVERALL - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
85 176
3/32" = 1'-0" F2
BASEMENT LEVEL FLOOR PLAN - MECHANICAL - DEMO - OVERALL*
0 8' 16'4'
E A
A
A R
E A
B
A R
E A
A
A R
E A
B
TU R
10KL
MNOPQS
5s 6 6s 7m
7s
J
Jw
Cm
2 3
4 4s
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
4" SAN 4" SAN
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:0
P
M
B138-M100-A
BASEMENT LEVEL FLOOR PLAN -
AREA A - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
86 176
1/8" = 1'-0" F3
BASEMENT LEVEL FLOOR PLAN - AREA A - MECHANICAL - DEMO
0 8' 16'4'
SHEET NOTES:
1. REMOVE SECTION OF EXISTING 22X7 DUCT AND RELOCATE EAST. REFER TO NEW WORK PLAN FOR
RELOCATION.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
ROOMS. DRAIN PANS TO BE PROVIDED WITH WATER BUG SENSORS WITH ALARM TO THE DDC.
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
A R
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
191817161515s
13 14
14s13s
J
Jw
Cm
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
DCW
DHW
DHWC
18x16 20x12
14x12 8ø
HPS
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:0
P
M
B138-M100-B
BASEMENT LEVEL FLOOR PLAN -
AREA B - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
87 176
1/8" = 1'-0" F3
BASEMENT LEVEL FLOOR PLAN - AREA B - MECHANICAL - DEMO
0 8' 16'4'
SHEET NOTES:
1. WATER CLOSET AND TRIM TO BE REPLACED WITH NEW. REFER TO NEW WORK PLAN.
2. LAVATORY TO BE SALVAGED FOR RELOCATION. DEMOLISH EXISTING LAVATORY FAUCET AND TRIM. REFER
TO NEW WORK PLAN FOR ADDITIONAL INFORMATION. EXISTING BRANCH WATER LINES AND ISOLATION
VALVES TO BE REUSED.
3. EXISTING WATER AND STEAM LINES IN SPACE TO REMAIN. REFER TO NEW WORK PLANS FOR DRAIN PAN
AND SENSOR REQUIREMENTS.
4. DEMOLISH EXISTING EXHAUST DUCTWORK SERVING BATHROOM.
5. DEMOLISH EXISTING SPRINKLER HEADS.
6. DEMOLISH ONE EXISTING SUPPLY DUCT AND ONE EXISTING RETURN DUCT AND ASSOCIATED DIFFUSERS
AND GRILLES THAT SERVE THE ROOM TO A POINT TWO FEET OUTSIDE THE PERIMETER OF THE ROOM.
ESTIMATED DUCT SIZES ARE NINE INCH.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
E A
B
A R
E A
C
A R
E A
B
A R
E A
C
27 28 29
23m
24s
25s 25 2626s
22 23s
J
Jw
Cm
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
DCW
DHW
DHWC
18x16 20x12
14x12
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:1
P
M
B138-M100-C
BASEMENT LEVEL FLOOR PLAN -
AREA C - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
88 176
1/8" = 1'-0" F3
BASEMENT LEVEL FLOOR PLAN - AREA C - MECHANICAL - DEMO
0 8' 16'4'
SHEET NOTES:
1. PRETEST SUPPLY AND EXHAUST OUTLETS IN MORGUE UNDER ALL OPERATING CONDITIONS AND RECORD
AND SUBMIT RESULTS TO THE COR. RECORD ROOM PRESSURIZATION LEVELS AS PART OF THE TEST AND
BALANCE.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
A R
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
TU R 27 28 29
23m
24s
25s 25 2626s
22 23s
191817161515s
13 14
14s13s
10KL
MNOPQS
5s 6 6s 7m
7s
J
Jw
Cm
2 3
4 4s
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
KEY PLAN
MAIN
ENTRY
BUILDING 138
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:1
P
M
B138-M101
FIRST LEVEL FLOOR PLAN -
OVERALL - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
89 176
3/32" = 1'-0"F2
FIRST LEVEL FLOOR PLAN - MECHANICAL - DEMO - OVERALL*
E A
A
A R
E A
B
A R
E A
A
A R
E A
B
TU R
10KL
MNOPQS
5s 6 6s 7m
7s
J
Jw
Cm
2 3
4 4s
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:1
P
M
B138-M101-A
FIRST LEVEL FLOOR PLAN - AREA
A - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
90 176
1/8" = 1'-0" F3
FIRST LEVEL FLOOR PLAN - AREA A - MECHANICAL - DEMO
0 8' 16'4'
SHEET NOTES:
1. DEMOLISH EXISTING ROOM SPRINKLER HEADS. DEMOLISH EXISTING SPRINKLER PIPING AS NECESSARY TO
ACCOMMODATE NEW WORK PLAN.
2. DEMOLISH HEATING HOT WATER LINES ROUTING TO EXISTING CABINET HEATER IN STAIRWELL. SEE NEW
WORK PLAN FOR NEW LINES TO SERVE CABINET UNIT HEATER.
3. EXISTING TERMINAL BOX TO BE SAVED FOR RELOCATION. REFER TO NEW PLAN FOR NEW LOCATION.
CONFIRM EXISTING BALANCE AIRFLOW BEFORE REMOVED.
4. DEMOLISH HEATING HOT WATER LINE SERVING TERMINAL AIR BOX AND UNIT HEATER. REFER TO NEW WORK
PLAN FOR NEW HEATING HOT WATER LINES.
5. UNIDENTIFIED BLACK COATED PIPE IN CEILING. DEMOLISH EXTENTS OF PIPE WITHIN BOUNDARIES OF NEW
TR ROOM.
6. EXISTING STEAM LINES TO REMAIN. PROVIDE DRAIN PAN WITH WATERBUG ALARM. ALARM TO BUILDING
MANAGEMENT SYSTEM.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
A R
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
191817161515s
13 14
14s13s
J
Jw
Cm
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
EXPECTED AREA OF
DEMOLITION AND REWORK
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:1
P
M
B138-M101-B
FIRST LEVEL FLOOR PLAN - AREA
B - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
91 176
1/8" = 1'-0" F3
FIRST LEVEL FLOOR PLAN - AREA B - MECHANICAL - DEMO
0 8' 16'4'
SHEET NOTES:
1. DEMOLISH SUPPLY DUCTWORK AS SHOWN AND CAP END OF EXISTING DUCT. TEST UPSTREAM TERMINAL
BOX AND DOWNSTREAM OUTLETS BEFORE DEMOLITION AND RECORD RESULTS. REBALANCE EXISTING DIFFUSERS TO REMAIN TO PRE-BALANCE READINGS AND REDUCE TERMINAL AIR BOX SETTING TO NEW
VALUES.
2. DEMOLISH HEATING HOT WATER MAINS ROUTING THROUGH PROPOSED TR SPACE AS SHOWN. REFER TO
NEW WORK PLAN FOR REROUTING.
3. DEMOLISH HEATING HOT WATER LINES ROUTING TO EXISTING HEATING UNIT IN STAIRWELL. REFER TO NEW
WORK PLAN FOR REROUTING.
4. EXISTING STEAM LINES SERVING HEATER IN STAIRWELL TO REMAIN. PROVIDE DRAIN PAN UNDER PIPING
WITH WATERBUG ALARM TO DDC.
5. EXISTING ISOLATION EXHAUST DUCT TO REMAIN.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
E A
B
A R
E A
C
A R
E A
B
A R
E A
C
27 28 29
23m
24s
25s 25 2626s
22 23s
J
Jw
Cm
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
EXPECTED AREA
OF DEMOLITION
AND REWORK
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:2
P
M
B138-M101-C
FIRST LEVEL FLOOR PLAN - AREA
C - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
92 176
1/8" = 1'-0" F3
FIRST LEVEL FLOOR PLAN - AREA C - MECHANICAL - DEMO
0 8' 16'4'
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
A R
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
TU R 27 28 29
23m
24s
25s 25 2626s
22 23s
191817161515s
13 14
14s13s
10KL
MNOPQS
5s 6 6s 7m
7s
J
Jw
Cm
2 3
4 4s
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
KEY PLAN
MAIN
ENTRY
BUILDING 138
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:2
P
M
B138-M102
SECOND LEVEL FLOOR PLAN -
OVERALL - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
93 176
3/32" = 1'-0" F2
SECOND LEVEL FLOOR PLAN - MECHANICAL - DEMO - OVERALL*
E A
A
A R
E A
B
A R
E A
A
A R
E A
B
TU R
10KL
MNOPQS
5s 6 6s 7m
7s
J
Jw
Cm
2 3
4 4s
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
1 2
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:3
P
M
B138-M102-A
SECOND LEVEL FLOOR PLAN -
AREA A - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
94 176
1/8" = 1'-0" F3
SECOND LEVEL FLOOR PLAN - AREA A - MECHANICAL - DEMO
0 8' 16'4'
SHEET NOTES:
1. DEMOLISH SUPPLY DIFFUSER AND ASSOCIATED SUPPLY DUCT SERVING OFFICE 226. REFER TO NEW WORK
PLAN FOR SUPPLY AIR REVISIONS TO THIS SPACE. EXISTING SUPPLY DUCT THROUGH SPACE TO REMAIN.
2. DEMOLISH EXISTING RETURN DUCT AND RETURN DIFFUSER IN OFFICE 226 BACK TO CONNECTION TO MAIN.
3. DEMOLISH EXISTING ROOM SPRINKLER HEADS. DEMOLISH EXISTING SPRINKLER PIPING AS NECESSARY TO
ACCOMMODATE NEW WORK PLAN.
4. REMOVE SECTION OF DUCT AT PENETRATION OF WALL AND REPLACE WITH MINIMUM 22 GAUGE SHEET
METAL AND THROUGH PENETRATION FIRE STOPPING TO MEET WALL RATINGS TO AVOID INSTALLATION OF
FIRE DAMPER.
5. CONFIRM AIR BALANCE OF SUPPLY DIFFUERS DOWNSTREAM OF EXISTING OFFICE 226. AFTER COMPLETION
OF NEW WORK, RETURN DIFFUSERS TO PREVIOUS AIR BALANCE VALUES.
6. EXISTING STEAM RISERS AND LATERAL PIPING IN SPACE TO REMAIN. PROVIDE DRAIN PAN WITH WATER BUG
SENSOR ALARM IN DRAIN PAN. WATER BUG TO ALARM TO BUILDING MANAGEMENT SYSTEM.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
A R
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
191817161515s
13 14
14s13s
J
Jw
Cm
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:3
P
M
B138-M102-B
SECOND LEVEL FLOOR PLAN -
AREA B - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
95 176
1/8" = 1'-0" F3
SECOND LEVEL FLOOR PLAN - AREA B - MECHANICAL - DEMO
0 8' 16'4'
SHEET NOTES:
1. REMOVE SUPPLY DUCTWORK TO OUTSIDE THE ROOM.
2. REMOVE ALL DOMESTIC AND SANITARY PIPING SERVING SINK. BACK TO THEIR CONNECTIONS TO MAINS AND
CAP. REMOVE PIPING AND VALVES ABOVE THE CEILING BACK TO MAIN CONNECTIONS AND CAP.
3. CAP EXISTING EXHAUST DUCT SERVING PHYSIATRY HOOD ABOVE CEILING.
4. DEMOLISH EXISTING ROOM SPRINKLER HEADS. DEMOLISH EXISTING SPRINKLER PIPING AS NECESSARY TO
ACCOMMODATE NEW WORK PLAN.
5. DEMOLISH WALL HUNG LAVATORY. PREPARE PLUMBING CONNECTIONS FOR CONNECTION TO NEW SINK.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
A R
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
TU R 27 28 29
23m
24s
25s 25 2626s
22 23s
191817161515s
13 14
14s13s
10KL
MNOPQS
5s 6 6s 7m
7s
J
Jw
Cm
2 3
4 4s
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
KEY PLAN
MAIN
ENTRY
BUILDING 138
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:3
P
M
B138-M103
THIRD LEVEL FLOOR PLAN -
OVERALL - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
96 176
3/32" = 1'-0" F2
THIRD LEVEL FLOOR PLAN - MECHANICAL - DEMO - OVERALL*
E A
A
A R
E A
B
A R
E A
A
A R
E A
B
TU R
10KL
MNOPQS
5s 6 6s 7m
7s
J
Jw
Cm
2 3
4 4s
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
STAIRS
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:3
P
M
B138-M103-A
THIRD LEVEL FLOOR PLAN - AREA
A - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
97 176
1/8" = 1'-0"F3
THIRD LEVEL FLOOR PLAN - AREA A - MECHANICAL - DEMO
0 8' 16'4'
SHEET NOTES:
1. REMOVE MEDICAL GAS PIPING IN CEILING BACK TO CONNECTION TO MAIN AND CAP.
2. REMOVE ALL DOMESTIC AND SANITARY PIPING SERVING SINK BACK TO THEIR CONNECTIONS TO MAINS AND
CAP. REMOVE PIPING AND VALVES ABOVE THE CEILING BACK TO MAIN CONNECTIONS AND CAP.
3. STEAM PIPING RISER SERVING THIRD FLOOR TO REMAIN. PROVIDE WATER BUG ALARM SENSOR AT FLOOR
LEVEL. WATER BUG TO ALARM TO BUILDING MANAGEMENT SYSTEM.
4. DEMOLISH EXISTING ROOM SPRINKLER HEADS.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
A R
E A
A
A R
E A
B
A R
E A
B
A R
E A
C
191817161515s
13 14
14s13s
J
Jw
Cm
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
STAIRS
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022
B
IM
/2
V
A M a ri o n E
H R
M I n fr a s tr u c tu re U p g ra d e s D e s ig n /6
-7
.B
.T
R
.r v t
/1
/2
:3
:4
P
M
B138-M103-B
THIRD LEVEL FLOOR PLAN - AREA
B - MECHANICAL - DEMO
EHRM INFRASTRUCTURE
UPGRADES, MARION, IN
MARION, IN
610-21-701
B138
04/15/2022 JMM GTS
16181
98 176
1/8" = 1'-0" F3
THIRD LEVEL FLOOR PLAN - AREA B - MECHANICAL - DEMO
0 8' 16'4'
SHEET NOTES:
1. REMOVE AND SALVAGE EXISTING WINDOW AIR CONDITIONERS FOR RE-USE.
2. DEMOLISH EXISTING ROOM SPRINKLER HEADS.
3. DEMOLISH TWO PERIMETER CABINET UNIT HEATERS AND PIPING BACK TO CONNECTION TO MAIN.
GENERAL NOTES:
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR
DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER
PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
5. WHETHER INDICATED BY OTHER PLAN NOTES OR NOT, PROVIDE A DRAIN PAN UNDER ALL EXISTING OR NEW HORIZONTAL PLUMBING OR MECHANICAL PIPING LOCATED IN TR ROOMS, SERVER ROOMS OR ENTRANCE
E A
B
A R
E A
C
A R
E A
B
A R
E A
C
27 28 29
23m
24s
25s 25 2626s
22 23s
J
Jw
Cm
Im
Iw
Hm
A
B
C
D
E
F
G
H
Am
Bw
I
STAIRS
BATH
340A
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com
SES PROJECT #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% FINAL STAMPED
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
20459 Sheet of
04/15/2022