Atch 20 - BLDG 29.pdf

PDF 10 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud Federal contract opportunity
Solicitation number
36C77622B0035
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document provides details for a federal contract solicitation to upgrade infrastructure at the St. Cloud Veterans Affairs Health Care System facility. The solicitation seeks a contractor to provide all labor, materials, tools and equipment for electrical, bonding, UPS, building management system, access security, and HVAC improvements. Additional requirements include assessing needs for new and upgraded systems, expanding and renovating existing space, upgrading physical security for data center and server rooms, installing diversified fiber pathways, and accessing and upgrading the campus-wide fiber infrastructure backbone within and between buildings. The contractor must also address any hazardous materials abatement needs. All work must be completed according to the specifications and contract drawings. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud, newest first.
File Type Posted
Atch 41 - Construction Wage Rates - Stearns 7-29-22.pdf PDF
Atch 3 - Specifications Volume 3 - Asbestos addendum.pdf PDF
Atch 4 - General 1 of 2 addendum.pdf PDF
Atch 6 - BLDG 1 - 1 of 2 addendum.pdf PDF
Atch 8 - BLDG 2 addendum.pdf PDF
Atch 9 - BLDG 3 addendum.pdf PDF
Atch 12 - BLDG 6 addendum.pdf PDF
Atch 13 - BLDG 7 and 13 addendum.pdf PDF
Atch 27 - BLDG 96 addendum.pdf PDF
Atch 30 - BLDG 111 addendum.pdf PDF
Atch 31 - BLDG 112 addendum.pdf PDF
Atch 5 - General 2 of 2 addendum.pdf PDF
Atch 14 - BLDG 8 addendum.pdf PDF
Atch 15 - BLDG 9 addendum.pdf PDF
Atch 20 - BLDG 29 addendum.pdf PDF
Atch 22 - BLDG 49 addendum.pdf PDF
Atch 24 - BLDG 51 addendum.pdf PDF
Atch 25 - BLDG 54 and 69 addendum.pdf PDF
Atch 32 - BLDG 115 addendum.pdf PDF
OIT Design Requirements - St. Cloud - Backbone Cabling.zip ZIP file
Atch 10 - BLDG 4 addendum.pdf PDF
Atch 21 - BLDG 48 addendum.pdf PDF
36C77622B0035 0001.pdf PDF
36C77622B0035 - 6-9-22.pdf PDF
Atch 6 - BLDG 1 - 1 of 2.pdf PDF
Atch 16 - BLDG 10.pdf PDF
Atch 19 - BLDG 28.pdf PDF
Atch 22 - BLDG 49.pdf PDF
Atch 35 - ADHC.pdf PDF
Atch 1 - Specifications Volume 1.pdf PDF
Atch 7 - BLDG 1 - 2 of 2.pdf PDF
Atch 12 - BLDG 6.pdf PDF
Atch 15 - BLDG 9.pdf PDF
Atch 18 - BLDG 14.pdf PDF
Atch 21 - BLDG 48.pdf PDF
Atch 25 - BLDG 54 and 69.pdf PDF
Atch 26 - BLDG 95 and 88.pdf PDF
Atch 28 - BLDG 108.pdf PDF
Atch 30 - BLDG 111.pdf PDF
Atch 32 - BLDG 115.pdf PDF
Atch 36 - Parking Structure.pdf PDF
Atch 40 - Limitations on Subcontracting - Construction.docx DOCX document
Atch 43 - Site Visit Instructions.pdf PDF
Atch 4 - General 1 of 2.pdf PDF
Atch 5 - General 2 of 2.pdf PDF
Atch 8 - BLDG 2.pdf PDF
Atch 23 - BLDG 50.pdf PDF
Atch 24 - BLDG 51.pdf PDF
Atch 27 - BLDG 96.pdf PDF
Atch 31 - BLDG 112.pdf PDF
Show all 50

Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXISTING FIBER - INSIDE

VFY EXIST

EXISTING FIBER - OUTSIDE

VFY EXIST

FIBER ROUTE - INSIDE

SEE TELECOM

FIBER ROUTE - OUTSIDE

SEE CIVIL

BUILDING OUTLINE

VFY EXIST

CORRIDOR OUTLINE

VFY EXIST

LEGEND

TO 8TH ST WEST ONLYTO 8TH ST EAST & WEST

44TH AVE.

TRAIL 1

TRAIL 2

TRANSFER

SWITCH

CAPACITOR

BANK (3)

SWITCH

(2)

15KV

MAIN

SW

BATT

35 KV

TO

15 KV

TRANSFORMER

35KV

FUSED

SWITCH

METER 35KV

SWITCH

GRAVEL

GRAVEL

GRAVEL

EXISTING

ROAD

CHAIN LINK FENCE

CHAIN LINK FENCE

16' GATE

GRAVEL

ELECTRICAL

SUBSTATION

G E N E R A T O R

FUEL LINES

CONDU ITS TO TU NNEL

M V

D U

C T

B A

N K

1 1 2 W

PHARMACY ADDITION

11 2 E

G E N E R A T O R

B

CORRIDOR LINK

A

C T

TR

A

IL

ER

174 s .f.

256 s .f.

185 s .f.

149 s ..f.

155 s .f.

104 s .f.

70 s. .f .

72 s .f.

110 s .f.

276 s .f.

112 s .f.

99 s .f.

57 s .f.

146 s .f.

434 s .f.

R A

MP

U P

1:

M A X

R A

MP

U P

1:

M A X

RA

M P

UP

1:2 0 M

AX

TRANSFER

SWITCH

CAPACITOR

BANK (3)

SWITCH

(2) 15KV

MAIN

SW

BATT

35 KV

TO

15 KV

TRANSFORMER

35KV

FUSED

SWITCH

METER 35KV

SWITCH

.3

TRANSFORMER

BUILD ING

#91

5,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

EXISTIN G G AS SU P P LY EQ U IP M EN T TO R EM AIN

O P ER ATIO N AL DU R IN G D EM O LITIO N AN D N EW

C O N STR U C TIO N. P R O TEC T EQU IP M EN T AN D

P IP ELIN ES IN AC C O R D AN C E W ITH G AS SU P P LIER 'S

R EC O M M EN D ATIO N S

N EW G AS SU P P LY M AIN

IN TO B U ILD IN G

SP AR E

P H O N E LIN E

EXTEN D S TO

E XISTIN G

P H O N E IN

B O ILER R O O M

P ER P LAN .

SP AR E

P H O N E

LIN E TO

M ETER

TU N N EL

E XTEN D S

A D D ITIO N AL

2'- 0" U N D ER

B U ILD IN G

FUEL LINE

VENT LINE

1,000 GAL.

UNDERGROUND

DIESEL FUEL

TANK

1,000/5,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

1,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

1,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

S 1

LIG H T

N EW G AS SU P P LY

(C O O R D IN ATE W ITH SU P P LIER )

12"D

10"D

"D

TP TP

EXIST. BUILDING

EXIST.

BUS STOP

CC

L O

O P

16"

20"

12"

3"

8"

DN

0.

0’

BIRDCAGE

B

IR

D C

A G

E

NSP ELECTRICAL

FOR HWY DEPT

T101

I.T.

CHILLER

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

VESTIBULE

DN

DN

DN

FD

DN

F B

F

B

F B

F

B

F B

F

B

SOUTH

VESTIBULE

PASS

THROUGH

LINK TO

BUILDI NG 51

6 3. 32 56

1 13 5. 35 78

PARKING

NO

PARKING

93 49

37 6

109 5

1A

S M

O K

E B

L D

G

SMOKE

BLDG

SMOKE

BLDG

S M

O K

E B

L D

G

SMOKE

BLDG

M.H.

STOR.

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

STOR.

BIO-

HAZ.

SAUK RIVER

GP

HOLDING POND29

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

OWNER AND

CONSULTANTS:

CONTACT:

ADDRESS:

MIKE ENGMARK

ST CLOUD VA MEDICAL CENTER

4801 VETERANS DRIVE

ST. CLOUD, MN 56303

NAME:

ADDRESS:

CONTACT:

ADVANCED STRUCTURAL TECHNOLOGIES

7301 OHMS LANE; SUITE 215

EDINA, MN 55439

ZACHARY CRAIG

PHONE:

NAME:

ADDRESS:

CONTACT:

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

KRIS BURNHAM

PHONE: 402-991-5520

NAME:

ADDRESS:

CONTACT:

PHONE:

NAME:

ADDRESS:

CONTACT:

PHONE:

NAME:

ADDRESS:

CONTACT:

PHONE:

ANDERSON ENGINEERING OF MN, LLC

13605 1ST AVE NORTH, SUITE 100

PLYMOUTH, MN 55441

IAN WEBER

763-412-4000

ARCHITECT:

ANDERSON ENGINEERING OF MN, LLC

13605 1ST AVE NORTH, SUITE 100

PLYMOUTH, MN 55441

EDWARD MARKFORT

763-412-4000

952-854-9302

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

KRIS BURNHAM

402-991-5520

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

COVER

DATE:

APPROVED: APPROVED: PROJECTS SECTION MANAGER

APPROVED: OIT MANAGER DATE: APPROVED: ASSISTANT CHIEF ENGINEER DATE:

APPROVED: SAFETY MANAGER

APPROVED: CHIEF OF POLICE

APPROVED: PATIENT SAFETY

DATE:

DATE:

DATE: APPROVED: EMS MANAGER

APPROVED: M/O MANAGER

DATE:

DATE:

DATE:DATE:

APPROVED: MEDICAL CENTER DIRECTOR

APPROVED: PROJECT COR DATE:

APPROVED: INFECTION CONTROL NURSE DATE:

APPROVED: SERVICE LINE DIRECTOR

APPROVED: GEMS COORDINATOR DATE:

DATE:

APPROVED: NURSE EXECUTIVE

APPROVED: CHIEF OF STAFF DATE:

APPROVED: DIRECTOR FMS

APPROVED: ASSOCIATE DIRECTOR

DATE:

DATE:

DATE:

DATE:APPROVED: DATE:

APPROVED: DATE:

APPROVED: DATE:

Main Campus, St. Cloud, Minnesota St. Cloud VA Health Care System

N

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

VICINITY MAP:

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHONE: 320-252-1670

CIVIL ENGINEER:

VA COR:

TELECOMMUNICATIONS ENGINEER:

CONTACT:

ADDRESS:

JONATHAN WEST

ST CLOUD VA MEDICAL CENTER

4801 VETERANS DRIVE

ST. CLOUD, MN 56303

PHONE: 504-250-2699

PROGRAM MANAGER:

EMAIL: Jonathan.West@vciint.com

STRUCTURAL ENGINEER:

MECH/ELEC/PLUMB/FIRE ENGINEER:

C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -2

-R

E

M a rk fo rt

.r v t

/2

/2

:0 :4

P

M

29-GI000

BUILDING 29 COVER SHEET &

SHEET INDEX

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

BUILDING 29 - EHRM INFRASTRUCTURE UPGRADES

03/30/2022

0APPROX 150' 300'75'

SHEET INDEX - BUILDING 29

SHEET NO. SHEET TITLE

29-TN120 SECOND FLOOR PLAN - TELECOMMUNICATIONS

29-TN130 ATTIC FLOOR PLAN - TELECOMMUNICATIONS

29-TN200 BASEMENT FLOOR PLAN - TELECOM - CABLE DISTANCE

29-TN210 FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE

29-TN400 ENLARGED PLANS - TELECOMMUNICATIONS

29-TN401 ENLARGED PLANS - TELECOMMUNICATIONS

29-E200 BASEMENT - ELECTRICAL

29-E201 FIRST FLOOR - ELECTRICAL

29-E300 ELECTRICAL ENLARGED PLANS

29-M100 BASEMENT DEMOLITION - MECHANICAL

29-M101 FIRST FLOOR DEMOLITION - MECHANICAL

29-M200 BASEMENT FLOOR - MECHANICAL

29-M201 FIRST FLOOR REMODEL - MECHANICAL

SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION

SHEET INDEX - BUILDING 29

SHEET NO. SHEET TITLE

29-GI000 BUILDING 29 COVER SHEET & SHEET INDEX

29-GI101 BASEMENT FLOOR - INFECTION CONTROL & PHASING PLAN

29-GI111 FIRST FLOOR - INFECTION CONTROL & PHASING PLAN

29-HA-1A REFERENCE - BASEMENT FLOOR ASBESTOS RE-SURVEY

29-HA-2A REFERENCE - FIRST FLOOR ASBESTOS RE-SURVEY

29-HA-3A REFERENCE - SECOND FLOOR ASBESTOS RE-SURVEY

29-HA-4A REFERENCE - ATTIC FLOOR ASBESTOS RE-SURVEY

29-AS100 BASEMENT PLANS

29-AS110 FIRST FLOOR PLANS

29-AS120 SECOND FLOOR - OVERALL PLAN

29-TD100 BASEMENT FLOOR PLAN - TELECOM - DEMOLITION

29-TD110 FIRST FLOOR PLAN - TELECOM - DEMOLITION

29-TD120 SECOND FLOOR PLAN - TELECOM - DEMOLITION

29-TD130 ATTIC FLOOR PLAN - TELECOM - DEMOLITION

29-TN100 BASEMENT FLOOR PLAN - TELECOMMUNICATIONS

29-TN110 FIRST FLOOR PLAN - TELECOMMUNICATIONS

ROOM SCHEDULE

NO. NAME C

A

B

LI

N G

P A

T C

H P

A N

E L

F

IB

E R

P O

W E

R

B O

N D

IN

G

U P

S

D E

D

IC

A T

E D

C O

O

LI

N G

T E

M P

E R

A T

U R

E

H U

M

ID

IT

Y

R A

C K

S E

N S

O R

S P

A C

E

AREA

WIDTH

(FT)

LENGTH

(FT)

HT TO

CLG

STRUCT REMARKS

BASEMENT

015 TELECOM ROOM X X X X X X X X 116 SF 7.5 15.6 10.00 UPDATE EXIST IT/DATA ROOM TO EHRM TELECOM

ROOM STANDARDS. SEE TELECOM DRAWINGS

FIRST FLOOR

144 TELECOM ROOM X X X X 88 SF 6.0 14.7 10.25 UPDATE EXIST IT/DATA ROOM TO EHRM TELECOM

ROOM STANDARDS. SEE TELECOM DRAWINGS

OPENING SCHEDULE

VA Building Number

ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION

H D

W G

R O

U P

F

IR

E L

A B

E L

(M

IN

G A

S K

E T

E

LE

C T

R

IC

A L

S L

A B

E L

COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT

PANEL

TYPE

2ND

PANEL

TYPE

PANEL

GLAZING FRAME TYPE

FRAME

GLAZING

HAZARDOUS MATERIAL SCHEDULE

LEVEL

ROOM

NO. ROOM NAME

QUESTIONABLE HAZARDOUS

ELEMENT POSSIBLE ABATEMENT ACTION

BASEMENT 015 TELECOM ROOM NONE. SEE 29-HA-1A NONE. ABATEMENT COMPLETE UNDER SEPARATE CONTRACT

FIRST FLOOR 144 TELECOM ROOM NONE. WINDOW CAULK OUTSIDE OF

ROOM. SEE 29-HA-2A

NONE. ACM TO REMAIN UNDISTURBED

HAZARDOUS MATERIALS MAY BE ENCOUNTERED THROUGHOUT THE DISTRIBUTION ROUTING THROUGH CEILING PLENUMS AND UTILITY TUNNELS. INSTALLATION OF DISTRIBUTION SHALL NOT

DISTURB QUESTIONABLE HAZARDOUS MATERIAL.

LEAK PREVENTION / DIVERTER SCHEDULE

LEVEL

ROOM

NO. ROOM NAME OVERHEAD LEAK DIVERTER AND DRAIN PIPING LEAK PREVENTION BARRIER WATERPROOFING

BASEMENT 015 TELECOM ROOM

FIRST FLOOR 144 TELECOM ROOM

SEE GENERAL NOTES SHEET FOR DETAIL. MWP = MEMBRANE WATERPROOFING. MASONRY = FLUID-APPLIED WATERPROOFING. INT = INTERIOR. EXT = EXTERIOR

ICRA PHASE CONSTRUCTION ROOM SCHEDULE

LEVEL

ROOM

NO. ROOM NAME

CAI BLDG NAME /

FUNCTION

CONSTRUCTION

PROJECT ACTIVITY

INFECTION CONTROL

RISK GROUP

CONTROL

PROCEDURE CLASS SECTION

CONSTRUCTION ZONE /

OCCUPIED CONSTR

DAY /

NIGHT

BASEMENT 015 TELECOM ROOM PRIMARY CARE /

ADMINISTRATION

TYPE C GROUP 2 CLASS III WEST OCCUPIED CONSTRUCTION NIGHT

FIRST FLOOR 144 TELECOM ROOM PRIMARY CARE /

ADMINISTRATION

TYPE C GROUP 2 CLASS III WEST OCCUPIED CONSTRUCTION NIGHT

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S

KNOWLEDGE. FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

P2 P11A

TOILET

MALE

LOCKER

C0C

CORRIDOR

XFMR

STORAGE

20D

STORAGE

20C

STORAGE

OT/LOW

VISION

STORAGE

20A

STAIR

HALL

ENG

STORAGE

MAS

STORAGE

MALE

BATHROOM

AUDIOLOGY

RECEP/WAITING

STORAGE

20B

HAC

22FEMALE

LOCKER

STOR

PIPE

CHASE

VESTIBULE

19 TOILET

19H

CORR

C0C

TOILET

1A

TANK ROOM

STORAGE

20E

WAITING

6A

STAIR

STAIR

026 STORAGE

RECEPTION/

SECRETARY

19A

OFFICE

19B

MECHANICAL

19W

ADMIN

OFFICER

19C

EXAM

19V

RECEPTION/

SIGN-OUT

5A

EXAM

5G

OFFICE

5I

OFFICE

5J

OFFICE

5K

FITTING

5H

EXAM

5C

AUX.

ROOM

5B

EXAM

5E

SUB

WAITING

5L

EXAM

5F

MULTI

PURPOSE

5D

CLEAN

STORAGE

6B

EXAM

19U

EXAM

19T

EXAM

19S

EXAM

19I

EXAM

19J

EXAM

19K

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

F

IR

E

ACCESS PANEL

TELECOM

ROOM

INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND

LIMITS OF CONSTRUCTION

1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER

LOCATION, AND DOOR, WHERE SHOWN

TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER

LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.

UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -2

-R

E

M a rk fo rt

.r v t

/2

/2

:5 :0

A

M

29-GI101

BASEMENT FLOOR -

INFECTION CONTROL &

PHASING PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM BMW

16305

03/30/2022

1/8" = 1'-0"

BASEMENT - CONST BARRIER PLAN

ROOM ICRA SCHEDULE

LEVEL

ROOM

NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS

BASEMENT 015 TELECOM ROOM PRIMARY CARE / ADMINISTRATION TYPE C GROUP 2 CLASS III

FIRST FLOOR 144 TELECOM ROOM PRIMARY CARE / ADMINISTRATION TYPE C GROUP 2 CLASS III

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S

KNOWLEDGE. FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

N

0 8' 16'4'

REF.

U C

F

UCF

U C

F

U C

F

REF.

F E

C

F E

C

F E

C

FEC

F E

C

FEC

113A

C1C

C1W

113B

123 132 134

142A

C1E

143A

167 154

149151

146142140

130129

163 165

161 164

162159

157 160

155 158

153 156

C7

C6

127128

126 125

114 115

C2

107106

104 105

103102

101100

C1

C le a n U tility

B la n k e t W a rm e r

TELECOM

ROOM

INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND

LIMITS OF CONSTRUCTION

1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER

LOCATION, AND DOOR, WHERE SHOWN

TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER

LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.

UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -2

-R

E

M a rk fo rt

.r v t

/2

/2

:5 :0

A

M

29-GI111

FIRST FLOOR - INFECTION

CONTROL & PHASING PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM BMW

16305

03/30/2022

1/8" = 1'-0"

FIRST FLOOR - CONST BARRIER PLAN

ROOM ICRA SCHEDULE

LEVEL

ROOM

NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS

BASEMENT 015 TELECOM ROOM PRIMARY CARE / ADMINISTRATION TYPE C GROUP 2 CLASS III

FIRST FLOOR 144 TELECOM ROOM PRIMARY CARE / ADMINISTRATION TYPE C GROUP 2 CLASS III

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S

KNOWLEDGE. FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

N

0 8' 16'4'

-ASBESTOS-CONTAINING FIRE DOOR

-ASBESTOS-CONTAINING PIPE INSULATION (VERTICAL RISERS)

-ASBESTOS-CONTAINING BLACK MASTIC UNDER CARPET

-ASBESTOS-CONTAINING WINDOW CAULK

-ASBESTOS-CONTAINING MASTIC UNDER 12" FLOOR TILE

-ASBESTOS-CONTAINING PIPE INSULATION (HORIZONTAL RUNS)

CASTLE HILL ASSOCIATES, LLC.

N

S

W E

LEGEND

BUILDING #29 - BASEMENT FLOOR PLAN

-ASBESTOS-CONTAINING CONVECTOR REFRACTORY

-ASBESTOS-CONTAINING BASE COVE ADHESIVE

-ASBESTOS-CONTAINING WINDOW CAULK

CASTLE HILL ASSOCIATES, LLC.

N

S

W E

BUILDING #29 - FIRST FLOOR PLAN

-ASBESTOS-CONTAINING CONVECTOR REFRACTORY

-ASBESTOS-CONTAINING WINDOW CAULK

-ASBESTOS-CONTAINING PIPE INSULATION (VERTICAL RISERS)

-ASBESTOS-CONTAINING MASTIC UNDER 12" FLOOR TILE

CASTLE HILL ASSOCIATES, LLC.

N

S

W E

BUILDING #29 - SECOND FLOOR PLAN

-ASBESTOS-CONTAINING PIPE INSULATION (VERTICAL RISERS)

-ASBESTOS-CONTAINING PIPE INSULATION (HORIZONTAL RUNS)

CASTLE HILL ASSOCIATES, LLC.

N

S

W E

LEGEND BUILDING #29 - ATTIC FLOOR PLAN

P2 P11A

TOILET

MALE

LOCKER

C0C

CORRIDOR

XFMR

STORAGE

20D

STORAGE

20C

STORAGE

OT/LOW

VISION

STORAGE

20A

STAIR

HALL

ENG

STORAGE

MAS

STORAGE

MALE

BATHROOM

AUDIOLOGY

RECEP/WAITING

STORAGE

20B

HAC

22FEMALE

LOCKER

STOR

PIPE

CHASE

VESTIBULE

19 TOILET

19H

CORR

C0C

TOILET

1A

TANK ROOM

STORAGE

20E

WAITING

6A

STAIR

STAIR

026 STORAGE

RECEPTION/

SECRETARY

19A

OFFICE

19B

MECHANICAL

19W

ADMIN

OFFICER

19C

EXAM

19V

RECEPTION/

SIGN-OUT

5A

EXAM

5G

OFFICE

5I

OFFICE

5J

OFFICE

5K

FITTING

5H

EXAM

5C

AUX.

ROOM

5B

EXAM

5E

SUB

WAITING

5L

EXAM

5F

MULTI

PURPOSE

5D

CLEAN

STORAGE

6B

EXAM

19U

EXAM

19T

EXAM

19S

EXAM

19I

EXAM

19J

EXAM

19K

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

F

IR

E

ACCESS PANEL

TELECOM

ROOM

7'-5 3/4"

'-6

/2

29-AS100

TELECOM

ROOM

3'-9 1/2" 4" 3'-2 1/4"

TELECOM

ROOM

TELECOM

ROOM

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -2

-R

E

M a rk fo rt

.r v t

/2

/2

:5 :0

A

M

29-AS100

BASEMENT PLANS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

03/30/2022

N

0 8' 16'4' 1/8" = 1'-0"

BASEMENT FLOOR - OVERALL PLAN

1/4" = 1'-0"

ENLARGED FLOOR PLAN

N

0 8' 16'4'

N

0 4' 8'2'

N

0 4' 8'2'

1/4" = 1'-0"2

DEMOLITION PLAN

1/4" = 1'-0"

REFLECTED CEILING PLAN

RC1 RC2

_DEMOLITION PLAN KEYED NOTES

DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM

REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

_FLOOR PLAN KEYED NOTES

FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”

TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH

HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT

FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT

OVER FIRE RATING STAMP.

FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE

TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST

THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS

WITH FIRE CAULK.

FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

_REFLECTED CEILING PLAN KEYED NOTES

RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET

ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE

VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET

ROW OR SECTION.

RC2 OPEN TO STRUCTURAL FLOOR ABOVE

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

FL1

DE1 DE1

DE1

FL3 FL3

FL3

FL20

_SHEET NOTES

1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL

INFORMATION, LIFE SAFETY, ICRA, AND PHASING

2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING

CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO

THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND

ENGINEERS.

3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS

AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH

OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND

ENGINEERS.

4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND

PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL

DEMOLITION AND CONSTRUCTION REQUIREMENTS.

5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS

DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED

SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM

ROOMS.

C

F

UCF

U C

F

U C

F

REF.

F E

C

F E

C

F E

C

FEC

F E

C

FEC

113A

C1C

C1W

113B

123 132 134

142A

C1E

143A

167 154

149151

146142140

130129

163 165

161 164

162159

157 160

155 158

153 156

C7

C6

127128

126 125

114 115

C2

107106

104 105

103102

101100

C1

C le a n U tility

B la n k e t W a rm e r

CORRIDOR

TELECOM

ROOM

6'-0 1/4"

'-8

/2

29-AS110

TELECOM

ROOM

2'-9 3/4" 4" 2'-10 1/2"

TELECOM

ROOM

TELECOM

ROOM

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -2

-R

E

M a rk fo rt

.r v t

/2

/2

:5 :1

A

M

29-AS110

FIRST FLOOR PLANS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

03/30/2022

1/8" = 1'-0"

FIRST FLOOR - OVERALL PLAN

N

0 8' 16'4'

N

0 8' 16'4'

N

0 4' 8'2'

N

0 8' 16'4'

1/4" = 1'-0"

ENLARGED FLOOR PLAN

1/4" = 1'-0"

DEMOLITION PLAN

1/4" = 1'-0"

REFLECTED CEILING PLAN

FL3

RC1 RC2

_DEMOLITION PLAN KEYED NOTES

DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM

REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

_FLOOR PLAN KEYED NOTES

FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”

TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH

HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT

FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT

OVER FIRE RATING STAMP.

FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE

TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST

THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS

WITH FIRE CAULK.

FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

_REFLECTED CEILING PLAN KEYED NOTES

RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET

ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE

VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET

ROW OR SECTION.

RC2 OPEN TO STRUCTURAL FLOOR ABOVE

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

FL1

DE1 DE1

DE1

FL3

FL3

FL20

_SHEET NOTES

1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL

INFORMATION, LIFE SAFETY, ICRA, AND PHASING

2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING

CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO

THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND

ENGINEERS.

3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS

AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH

OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND

ENGINEERS.

4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND

PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL

DEMOLITION AND CONSTRUCTION REQUIREMENTS.

5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS

DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED

OFFICE

STAIR

HALL

OFFICE

STORAGE

OFFICE

OFFICE

OFFICE

OFFICE

SPD

STORAGE

PIPE CHASE

214A

PIPE CHASE

215A

PIPE CHASE

243A

OFFICE

OFFICE

CORRIDOR

C2CW

CORRIDOR

C2SW

OFFICE

TOUCHDOWN

ROOM

HAC

CORRIDOR

C2W

TOILET

TOILET

OFFICE

OFFICE

LOBBY

OFFICE

BATH

253A

PIPE CHASE

244A

OFFICE

OFFICE

CORRIDOR

C2SE

OFFICE

OFFICE

245A

OFFICE

245B

OFFICE

OFFICE

OFFICE

CLEAN

LINEN

201A

TOILET

LACTATION

ROOM

HAC

STOR.

TOI

204B

STOR.

OFFICE

STORAGE

OFFICE

231PHONE

CLOSET

231A

OFFICE

OFFICE

CONFERENCE

ROOM

STAIR

HALL

OFFICE

HAC

TOILET

PIPE CHASE

243A

CORRIDOR

C2E

STORAGE

ROOM

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORRIDOR

C2CE

CORRIDOR

C2SW

EXAM

ROOM

208A

EXAM

ROOM

208B

EXAM

ROOM

209A

EXAM

ROOM

209B

EXAM

ROOM

210A

EXAM

ROOM

210B

EXAM

ROOM

213B

EXAM

ROOM

213A

EXAM

ROOM

212B

EXAM

ROOM

212A

EXAM

ROOM

211B

EXAM

ROOM

211A

CORRIDOR

C2SW

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -2

-R

E

M a rk fo rt

.r v t

/2

/2

:5 :1

A

M

29-AS120

SECOND FLOOR - OVERALL

PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

03/30/2022

1/8" = 1'-0"1

SECOND FLOOR - OVERALL PLAN

N

0 8' 16'4'

_SHEET NOTES

1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL

INFORMATION, LIFE SAFETY, ICRA, AND PHASING

2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING

CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO

THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND

ENGINEERS.

3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS

AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH

OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND

ENGINEERS.

4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND

PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL

DEMOLITION AND CONSTRUCTION REQUIREMENTS.

5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS

DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED

UP

DISCHARGE

UP

UP

DN

RAMP

UP

UP

EXISTING GLYCOL TANK

EXISTING PUMPS/ EQUIPMENT

FEC

FEC

FEC

FEC

24x36

TABLE

24x48

TABLE

1A

TOILET

5B

ROOM

AUX.

5A

SIGN-OUT

RECEPT/

RECEP/WAITING

OPTOMETRY

MALE

CHASE

PIPE

C0C

CORRIDOR

C 0W

C O

R R

ID

O

R

STAIR

6F

OFFICE

6E

OFFICE

ELECTRICAL

STORE

CANTEEN

OFFICE

DATA

ROOM

TANK

STAIR

INTERN OFFICE

CHAPLAINS

20A

MECHANICAL

20D

CLASSROOM

20E

CLASSROOM

20C

CLASSROOM

20B

CLASSROOM

RECEPTION

5F

EXAM

5H

ROOM

EXAM

5I

OFFICE

5J

OFFICE

5K

OFFICE

STAIR

CHASE

CORR 027

CHASE

STAIR

STAIR

STAIR

HAC

5C

EXAM

5D

PURPOSE

MULTI

5E

EXAM

5G

EXAM

5L

CORR

20L

CLOSET

20K

CLOSET

20J

CLOSET

20I

CLOSET

20H

CLOSET

20G

CLOSET

20F

CLOSET

P1

ELEV

P1

ELEV

P2

ELEV

LOCKER

FEMALE

6D

OFFICE

6C

OFFICE

6B

LAB

AUDIOLOGY

RECEPTION

6A

WAITING

AUDIOLOGY

7A

FITTING

OFFICE

7B

FITTING

OFFICE

7C

FITTING

OFFICE

7D

FITTING

OFFICE

7E

OFFICE

EXAM

10A

MECHANICAL

SUITE

AUDIO/EXAM

SUITE

AUDIO/EXAM

SUITE

AUDIO/EXAM

STORAGE

SPD

CO2A

VOLTAGE

LOW

COWA

STOR

SOILED

CO1

HALL

CO1A

STORAGE

LINEN

CO1B

STORAGE

PROSTHETICS

CO2

CORRIDOR

EXIT

1-B

PHONE

EMERGENCY

19I

EXAM

19J

EXAM

19K

EXAM

19L

EXAM

19F

EXAM

19G

EXAM

19H

EXAM

19C

EXAM

19D

EXAM

19E

EXAM

19S

EXAM

19T

EXAM

19U

EXAM

19V

EXAM

19B

WAITING

19B.1

RECEPTION 19N

PRE-TEST

19O

PRE-TEST

19Q

PRE-TEST

19P

OFFICE

19Y

SUPPORT

C19-1

CORRIDOR

C19-3

CORRIDOR

19X

WAITING

DILATION

C19-4

CORRIDOR

19R

MEDS

19W

MECHANICAL

C 19-2

C O

R R

ID

O

R

18A

CORRIDOR

P

IP

E C

H A

S E 19A

ENTRY

F

IR

E

ACCESS PANEL

C

DATA

29-TD100

LIMITS OF DATA CABLING DEMOLITION

LIMITS OF DATA CABLING REPLACEMENT

FROM ROOM 015

FURNITURE FEED

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E

E E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E E E

E

E

E

E

E E

E

E

E

E

E E

E

E

E

EE

E

E

E

E

E

E

EE

E

E

E

E

E

E

E

E

EEE

E

E

E E

E E

E E

E

E

E

E E

E E

E

E

E

E

E E

E E

E

E

E

E

E E

E

E

E E

E

E E

E

4D

4D

4D

4D

2D/2V

2D/2V

4D

4D

4D

4D

5D 4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D 4D

4D

4D

4D

4D

4D

4D 4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D4D

4D

4D

4D

4D 4D

1V

4D

4D

4D 4D

4D 4D

4D

4D

4D 4D

4D

4D

4D 4D

4D

4D 4D

4D

4D 4D

4D

4D

4D

4D

4D 4D

4D

4D 4D

4D

4D 4D

4D

4D 4D

4D

4D 4D

4D

4D 4D

4D

4D

4D

4D

4D

4D 4D

4D

4D 4D

4D

4D

4D

4D

4D 4D

4D

4D 4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

1V

2D/2V

2D/2V

2D/2V

2D/2V

2D 4D

4D

4D

2D

2D

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

4D E

2D /2

V

2D/2V

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

EEE

E

E

E

E E

E

EE

E

E

E

12"x4" 12"x4" 12"x4"

"x

4"

"x 4"

"x

4"

12"x4"

"x

4"

"x

4"

EE

E

12"x4"

"x

4"

12"x4" 12"x4"

"x

4"

"x 4"

R

SP

TW

SP

AC

FAPS

D

E

E

E

E

E

DATA

RACK

CABLE

TRAY

R

DATA

RACKD

D

D

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:3

:5

P

M

29-TD100

BASEMENT FLOOR PLAN -

TELECOM - DEMOLITION

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

SHEET NOTES:

1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.

REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING

ROUTES.

2. EXISTING TELECOMMUNICATIONS CAGE AND RACK SHALL BE INCLUDED WITHIN THE SCOPE OF DEMOLITION.

EXISTING CABLING AND ASSOCIATED OUTLETS SHALL BE REMOVED AND REPLACED 1 FOR 1 AND REFED FROM DISTRIBUTION EQUIPMENT LOCATED WITHIN THE NEW TELECOMMUNICATIONS ROOM. REFER TO GENERAL CABLING NOTES FOR APPROXIMATE QUANTITIES. REFER TO NEW WORK PLANS FOR SERVING

COMMUNICATIONS ROOM LOCATION AND NEW CABLING ROUTES.

N

0 8' 16'4' 1/8" = 1'-0"

BASEMENT FLOOR PLAN - TELECOM - DEMOLITION

1/4" = 1'-0"

TELECOM DEMO - ENLARGED PLAN -EXIST RM 15

N

0 4' 8'2'

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

CABLING NOTE:

CABLING NOTES:

A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE

RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE

PROJECT.

1. ROOM 015

EXISTING CABLE COUNT

DATA (CAT6): 0

DATA (CAT5e): 460

DATA (CAT5): 0

DATA (CAT3): 0

CABLE RELOCATION COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

EXISTING CABLE TO REMAIN

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

FINAL CABLE COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

C

F

UCF

U C

F

U C

F

REF.

F E

C

F E

C

F E

C

FEC

F E

C

FEC

137A

STAIR

119A

STAIR

ENCOUNTER

PATIENT

TEAM 5 & 6

EXAM

EXAM

EXAM

EXAM

TOILET

PROCEDURE

C1E

CORRIDOR

142A

CHASE

PIPE

TEAM 3 & 4

143A

CHASE

PIPE

LOUNGE

STAFF

STORAGE

WAITING

SPD

CLEAN/

SOILED

MECH.

EXAM

EXAM

C3

CORR

WAITING

OPTOMETRY

TEAM 7 & 8

113B

CHASE

PIPE

113A

CHASE

PIPE

STAIR123

STAIR

RECEPTION

VESTIBULE

RECEPTION

P2

ELEV

P1

ELEV

TOILET

EXAM RM

OPTOMETRY

TOILET

LOBBY

TOILET

LINEN

C4

CORRIDOR

TEAM 1

TEAM 2

EXAM 1

EXAM 1

EXAM 2

EXAM 2

EXAM 3

EXAM 3

EXAM 4

EXAM 4

EXAM 5

EXAM 5

C7

CORRIDOR

STOR.

MED.

EXAM

C6

CORR.

EXAM

EXAM

STORAGE

MED

INFUSION

INFUSION

INFUSION

INFUSION

AREA

WORK122

INFUSION

INFUSION

INFUSION

INFUSION

INFUSION

INFUSION

WAITING

WAITING

TOILET

STORAGE

MED.

C2

CORRIDOR

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM

ENCOUNTER

PATIENT

ENCOUNTER

PATIENT

HAC

UTILITY

CLEAN

C1

CORRIDOR

C5

CORRIDOR

UTILITY

SOILEDC

le a n U tility

B la n k e t W a rm e r

REF.

U C

F

UCF

U C

F

U C

F

REF.

F E

C

F E

C

F E

C

FEC

F E

C

FEC

137A

STAIR

119A

STAIR

ENCOUNTER

PATIENT

TEAM 5 & 6

EXAM

EXAM

EXAM

EXAM

TOILET

PROCEDURE

C1E

CORRIDOR

142A

CHASE

PIPE

TEAM 3 & 4

143A

CHASE

PIPE

LOUNGE

STAFF

STORAGE

WAITING

SPD

CLEAN/

SOILED

MECH.

EXAM

EXAM

C3

CORR

WAITING

OPTOMETRY

TEAM 7 & 8

113B

CHASE

PIPE

113A

CHASE

PIPE

STAIR123

STAIR

RECEPTION

VESTIBULE

RECEPTION

P2

ELEV

P1

ELEV

TOILET

EXAM RM

OPTOMETRY

TOILET

LOBBY

TOILET

LINEN

C4

CORRIDOR

TEAM 1

TEAM 2

EXAM 1

EXAM 1

EXAM 2

EXAM 2

EXAM 3

EXAM 3

EXAM 4

EXAM 4

EXAM 5

EXAM 5

C7

CORRIDOR

STOR.

MED.

EXAM

C6

CORR.

EXAM

EXAM

STORAGE

MED

INFUSION

INFUSION

INFUSION

INFUSION

AREA

WORK122

INFUSION

INFUSION

INFUSION

INFUSION

INFUSION

INFUSION

WAITING

WAITING

TOILET

STORAGE

MED.

C2

CORRIDOR

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM

ENCOUNTER

PATIENT

ENCOUNTER

PATIENT

HAC

UTILITY

CLEAN

C1

CORRIDOR

C5

CORRIDOR

UTILITY

SOILEDC

le a n U tility

B la n k e t W a rm e r

C C C C

C

E

3D

3D 3D

3D

3D 3D

3D

3D 3D

3D

3D

3D

3D

3D3D

3D

3D

3D

3D

3D 3D

3D

3D

3D

3D 3D3D3D

3D 3D

3D

3D

3D

3D

3D

3D

3D

3D 3D 3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D3D

3D

3D

3D

3D

3D

3D

3D

3D 3D

3D

3D 3D

3D 3D

3D 3D 3D 3D 3D 3D 3D 3D

3D 3D3D 3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D 3D

3D 3D 3D

3D 1D 3D

3D 3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D 3D3D 3D

3D3D 3D3D3D

WAP

E E E E

E

E

E E

E

E

E

E

E E

E

E

E

E E E E

E E

E

E

E

E

E

E

E

E

EEE

E

E

E

E

E

E

E

E

E

E

EE

E E

E

E

E

E

E

E E E

E E

E E

E

EE

E

E

E

E

E E

E

E

E

E E E E E E E E

E E

E E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

EEE

E E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

EEEEE

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

EEEE

29-TD110

LIMITS OF DATA CABLING DEMOLITION

LIMITS OF DATA CABLING REPLACEMENT

FROM ROOM 144

E

E

E E E E

EE

E

E

E

E

E

E

"x

4"

"x

4"

"x

4"

"x

4"

"x

4"

"x 4"

12"x4"12"x4"

12"x4"

12"x4"

DATA RACK

D

D

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:3

:5

P

M

29-TD110

FIRST FLOOR PLAN -

TELECOM - DEMOLITION

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

N

0 8' 16'4' 1/8" = 1'-0"

FIRST FLOOR PLAN - TELECOM - DEMOLITION

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

1/4" = 1'-0"

TELECOM DEMO - ENLARGED PLAN -EXIST RM 144

N

0 4' 8'2'

CABLING NOTE:

CABLING NOTES:

A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE

RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE

PROJECT.

1. ROOM 144

EXISTING CABLE COUNT

DATA (CAT6): 0

DATA (CAT5e): 484

DATA (CAT5): 0

DATA (CAT3): 0

CABLE RELOCATION COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

EXISTING CABLE TO REMAIN

DATA (CAT6): 484

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

FINAL CABLE COUNT

DATA (CAT6): 484

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

SHEET NOTES:

1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.

REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING

ROUTES.

2. EXISTING TELECOMMUNICATIONS CAGE AND RACK SHALL BE INCLUDED WITHIN THE SCOPE OF DEMOLITION.

EXISTING CABLING AND ASSOCIATED OUTLETS SHALL BE REMOVED AND REPLACED 1 FOR 1 AND REFED FROM DISTRIBUTION EQUIPMENT LOCATED WITHIN THE NEW TELECOMMUNICATIONS ROOM. REFER TO GENERAL CABLING NOTES FOR APPROXIMATE QUANTITIES. REFER TO NEW WORK PLANS FOR SERVING

COMMUNICATIONS ROOM LOCATION AND NEW CABLING ROUTES.

30x30

DESK

30x30

DESK

30x30

DESK

30x54

DESK

24x48

DESK

24x48

DESK

FILE

LAT

P R

IN

T

E R

24x48

DESK

29-

EC2-1

214A

CHASE

PIPE

BATH

STORAGE

SPDC2W

CORR

HAC

ROOM

TOUCHDOWN

OFFICE

OFFICE

STORAGE

OFFICE

OFFICE

OFFICE

STAIR

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE 230

OFFICE 231

OFFICE

OFFICE

OFFICE

R.O.I.

STAIR

STOR

HAC

ROOM

LACTATION

OFFICE

OFFICE

CONFERENCE

C2E

CORR

HAC

STORAGE

COPY

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

243A

CHASE

PIPE

BATH

244A

CHASE

PIPE

OFFICE

245B

STORAGE

245A

OFFICE

OFFICE

OFFICE

C2SE

CORR

OFFICE

OFFICE

C2CW

CORRIDOR

OFFICE

C2CE

CORRIDOR

208A

ROOM

EXAM

208B

ROOM

EXAM

209A

ROOM

EXAM

209B

ROOM

EXAM

210A

ROOM

EXAM

210B

ROOM

EXAM

211A

ROOM

EXAM

211B

ROOM

EXAM

212A

ROOM

EXAM

212B

ROOM

EXAM

213A

ROOM

EXAM

213B

OFFICE

C2SW

CORR

OFFICE

LOBBY

OFFICE

253A

STORAGE

E02

ELEV

E01

ELEV

2D

2D

2D/2V

2D/2V

2D/2V

2D/1V

6D1D

5D/1V

3D 3D 3D 3D

2D

2D

2D

2D

2D

2D

2D

2D

1D

4D

4D

2D/2V

2D/2V 2D/2V

2D/2V

2D/2V

1D

2D/2V

2D/2V

2D/2V

2D/2V

2D/2V

2D/2V

2D/2V2D/2V

2D/2V

2D/2V

2D/2V

2D/2V 2D/2V

2D/2V

2D/2V

4D

4D

2D/3V

2D/3V

1D/1V

1D

1D/2V

2D/2V

1D

1D

1D/1V

3D/1V 1D/2V

3D

1D/2V

1D/2V

2D/2V E

E

E

E

E

E

E

E

E

E

WAP

WAP

WAP

WAP

WAP

1D

WAP

WAP

WAP

PROJECTOR

WAP

WAP

E

E

E

E

E

E

E

E

EE

E

E

E

E

E

E

EEEE

E

E

E

E E

E E

E

EE

E

E

E

E E

EE

E

E

E

E

E

E

E

E

EE

E

E

E

E

E

E

E

E

EE

E

E E

E

E E

E

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D1D

4D

4D

4D

4D

4D/1V

4D 4D 4D

4D

3D/1V

3D/1V

3D

3D

3D

2V

E

WAP

WAP

E

E

E

E E

E

E

E

E

E

E

E

E E

E E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

4D

4D

4D

4D

4D

4D

E 4D

E

E

E EE

E

E

E

E

E

E

"x

4"

"x

4"

"x 4"

"x

4"

"x 4"

12"x4" 12"x4"

LIMITS OF DATA CABLING DEMOLITION

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:3

:5

P

M

29-TD120

SECOND FLOOR PLAN -

TELECOM - DEMOLITION

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

N

0 8' 16'4' 1/8" = 1'-0"

SECOND FLOOR PLAN - TELECOM - DEMOLITION

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

SHEET NOTES:

1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.

REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING

ROUTES.

E

PENTHOUSE

ATTIC

E 3D

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:3

:5

P

M

29-TD130

ATTIC FLOOR PLAN -

TELECOM - DEMOLITION

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1/8" = 1'-0"

ATTIC FLOOR PLAN - ELECTRICAL - DEMOLITION

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

EXISTING GLYCOL TANK

EXISTING PUMPS/ EQUIPMENT

P2 P11A

TOILET

MALE

LOCKER

C0C

CORRIDOR

XFMR

STORAGE

20D

STORAGE

20C

STORAGE

OT/LOW

VISION

STORAGE

20A

STAIR

HALL

ENG

STORAGE

MAS

STORAGE

MALE

BATHROOM

AUDIOLOGY

RECEP/WAITING

STORAGE

20B

HAC

22FEMALE

LOCKER

STOR

PIPE

CHASE

VESTIBULE

19 TOILET

19H

CORR

C0C

TOILET

1A

TANK ROOM

STORAGE

20E

WAITING

6A

STAIR

STAIR

026 STORAGE

RECEPTION/

SECRETARY

19A

OFFICE

19B

MECHANICAL

19W

ADMIN

OFFICER

19C

EXAM

19V

RECEPTION/

SIGN-OUT

5A

EXAM

5G

OFFICE

5I

OFFICE

5J

OFFICE

5K

FITTING

5H

EXAM

5C

AUX.

ROOM

5B

EXAM

5E

SUB

WAITING

5L

EXAM

5F

MULTI

PURPOSE

5D

CLEAN

STORAGE

6B

EXAM

19U

EXAM

19T

EXAM

19S

EXAM

19I

EXAM

19J

EXAM

19K

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

F

IR

E

ACCESS PANEL

EXISTING GLYCOL TANK

EXISTING PUMPS/ EQUIPMENT

P2 P11A

TOILET

MALE

LOCKER

C0C

CORRIDOR

XFMR

STORAGE

20D

STORAGE

20C

STORAGE

OT/LOW

VISION

STORAGE

20A

STAIR

HALL

ENG

STORAGE

MAS

STORAGE

MALE

BATHROOM

AUDIOLOGY

RECEP/WAITING

STORAGE

20B

HAC

22FEMALE

LOCKER

STOR

PIPE

CHASE

VESTIBULE

19 TOILET

19H

CORR

C0C

TOILET

1A

TANK ROOM

STORAGE

20E

WAITING

6A

STAIR

STAIR

026 STORAGE

RECEPTION/

SECRETARY

19A

OFFICE

19B

MECHANICAL

19W

ADMIN

OFFICER

19C

EXAM

19V

RECEPTION/

SIGN-OUT

5A

EXAM

5G

OFFICE

5I

OFFICE

5J

OFFICE

5K

FITTING

5H

EXAM

5C

AUX.

ROOM

5B

EXAM

5E

SUB

WAITING

5L

EXAM

5F

MULTI

PURPOSE

5D

CLEAN

STORAGE

6B

EXAM

19U

EXAM

19T

EXAM

19S

EXAM

19I

EXAM

19J

EXAM

19K

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

F

IR

E

ACCESS PANEL

TELECOM ROOM

LIMITS OF DATA CABLING REPLACEMENT

FROM ROOM 015

12"x4"

12"x4"

"x

4"

12"x4"

12"x4"

G

G

FURNITURE FEED

WAP

WAP

WAP

E

4D

4D

4D

4D

2D/2V

2D/2V

4D

4D

4D

4D

5D 4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D 4D

4D

4D

4D

4D

4D 4D

4D

4D

4D

4D

4D

4D

4D

4D

4D 4D

4D4D

4D

4D

4D

4D 4D

1V

4D

4D

4D 4D

4D 4D

4D

4D

4D 4D

4D

4D

4D 4D

4D

4D 4D

4D

4D 4D

4D

4D

4D

4D

4D 4D

4D

4D 4D

4D

4D 4D

4D

4D 4D

4D

4D 4D

4D

4D 4D

4D

4D

4D

4D

4D

4D 4D

4D

4D 4D

4D

4D

4D

4D

4D 4D

4D

4D 4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

1V

2D/2V

2D/2V

2D/2V

2D/2V

2D 4D

4D

4D

2D

2D

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

E E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E

E E

E

E E

E

E

E

E

E

E E

E

E

E

E

E

E E E

E

E

E

E

E E

E

E

E

E

E E

E

E

E

EE

E

E

E

E

E

E

2D/2V

2D /2

V

EE

E

E

E

E

E

E

E

E

EEE

E

E

E E

E E

E E

E

E

E

E E

E E

E

E

E

E

E E

E E

E

E

E

E

E E

E

E

E E

E

E E

E

E 4D

E

2D

CABLE TRAY

29-TN400

4"

"x

4"

"x 4"

"x

4"

"x

4"

12"x4"

12"x4" 12"x4"

E

E

E

E

E E

EEEE

E

E

E

E E

E

EE

E

E

E

4"

EE

E

"x

4"

12"x4"

"x

4"

"x 4"

C5 126"

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:3

:5

P

M

29-TN100

BASEMENT FLOOR PLAN -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

SHEET NOTES:

1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.

2. PROVIDE JUNCTION BOX TO CONNECT FIBER CONDUIT ENTRY TO EXTEND CONDUIT PATHWAY TO THE NEW

TELECOM ROOM.

1/8" = 1'-0"

BASEMENT FLOOR PLAN - TELECOMMUNICATIONS

N

0 8' 16'4'

A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.

C

F

UCF

U C

F

U C

F

REF.

F E

C

F E

C

F E

C

FEC

F E

C

FEC

113A

C1C

C1W

113B

123 132 134

142A

C1E

143A

167 154

149151

146142140

130129

163 165

161 164

162159

157 160

155 158

153 156

C7

C6

127128

126 125

114 115

C2

107106

104 105

103102

101100

C1

C le a n U tility

B la n k e t W a rm e r

REF.

U C

F

UCF

U C

F

U C

F

REF.

F E

C

F E

C

F E

C

FEC

F E

C

FEC

113A

C1C

C1W

113B

123 132 134

142A

C1E

143A

167 154

149151

146142140

130129

163 165

161 164

162159

157 160

155 158

153 156

C7

C6

127128

126 125

114 115

C2

107106

104 105

103102

101100

C1

C le a n U tility

B la n k e t W a rm e r

C C C C

C

TELECOM ROOM

WAP E

3D

3D 3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D 3D3D3D

3D 3D

3D

3D

3D

3D

3D

3D

3D

3D 3D 3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D 3D

3D3D

3D

3D

3D

3D

3D

3D

3D

3D 3D 3D

3D 3D

3D 3D

3D 3D 3D 3D 3D 3D 3D 3D

3D 3D 3D 3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D 3D

3D 3D 3D

3D 1D 3D

3D 3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D

3D 3D3D 3D

3D3D 3D3D3D

E

EEEE

E

E E

E

E

E

E

E E

E

E

E

E E E E

E E

E

E

E

E

E

E

E

E

EEE

E

E

E

E

E

E

E

E

E

E

EE

E E

E

E

E

E

E

E E E

E E

E E

E

EE

E

E

E

E

E E

E

E

E

E E E E E E E E

E E

E E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

EEE

E E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

EEEEE

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

EEEE

LIMITS OF DATA CABLING REPLACEMENT

FROM ROOM 144

29-TN401

12"x4" 12"x4" 12"x4"

12"x4"

"x

4"

"x

4"

"x

4"

"x

4"

"x 4"

"x

4"

E

E

E E E E

EE

E

E

E

E

E

E

C5 126"

12"x4"

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:3

:0

P

M

29-TN110

FIRST FLOOR PLAN -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1/8" = 1'-0"

FIRST FLOOR PLAN - TELECOMMUNICATIONS

N

0 8' 16'4'

GENERAL NOTES:

A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.

SHEET NOTES:

1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.

OFFICE

STAIR

HALL

OFFICE

STORAGE

OFFICE

OFFICE

OFFICE

OFFICE

SPD

STORAGE

PIPE CHASE

214A

PIPE CHASE

215A

PIPE CHASE

243A

OFFICE

OFFICE

CORRIDOR

C2CW

CORRIDOR

C2SW

OFFICE

TOUCHDOWN

ROOM

HAC

CORRIDOR

C2W

TOILET

TOILET

OFFICE

OFFICE

LOBBY

OFFICE

BATH

253A

PIPE CHASE

244A

OFFICE

OFFICE

CORRIDOR

C2SE

OFFICE

OFFICE

245A

OFFICE

245B

OFFICE

OFFICE

OFFICE

CLEAN

LINEN

201A

TOILET

LACTATION

ROOM

HAC

STOR.

TOI

204B

STOR.

OFFICE

STORAGE

OFFICE

231PHONE

CLOSET

231A

OFFICE

OFFICE

CONFERENCE

ROOM

STAIR

HALL

OFFICE

HAC

TOILET

PIPE CHASE

243A

CORRIDOR

C2E

STORAGE

ROOM

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORRIDOR

C2CE

CORRIDOR

C2SW

EXAM

ROOM

208A

EXAM

ROOM

208B

EXAM

ROOM

209A

EXAM

ROOM

209B

EXAM

ROOM

210A

EXAM

ROOM

210B

EXAM

ROOM

213B

EXAM

ROOM

213A

EXAM

ROOM

212B

EXAM

ROOM

212A

EXAM

ROOM

211B

EXAM

ROOM

211A

CORRIDOR

C2SW

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

1D

PROJECTOR

2D

2D

2D/2V

2D/2V

2D/2V

2D/1V

6D1D

5D/1V

3D 3D 3D 3D

2D

2D

2D

2D

2D

2D

2D

2D

1D

4D

4D

2D/2V

2D/2V 2D/2V

2D/2V

2D/2V

1D

2D/2V

2D/2V

2D/2V

2D/2V

2D/2V

2D/2V

2D/2V2D/2V

2D/2V

2D/2V

2D/2V

2D/2V 2D/2V

2D/2V 2D/2V

4D

4D

2D/3V

2D/3V

1D/1V

1D

1D/2V

2D/2V

1D

1D

1D/1V

3D/1V 1D/2V

3D

1D/2V

1D/2V

2D/2V

WAP

E

E

E

E

E

E

E

WAP

E

WAP

WAP

E

WAP

E

WAP

WAP

WAP

WAP

WAP

E

E

E

E

E

E

E

E

EE

E

E

E

E

E

E

EEEE

E

E

E

E E

E E

E

EE

E

E

E

E E

EE

E

E

E

E

E

E

E

E

EE

E

E

E

E

E

E

E

E

EE

E

E E

E

E E

WAP

WAP

E

E

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D

4D1D

4D

4D

4D

4D

4D/1V

4D 4D 4D

4D

3D/1V

3D/1V

3D

3D

3D

2V

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E E

E

E

E

E

4D

4D 4D

4D

4D

4D

E

E

E

E

E

E

4D E

E

E

E E

EE

E

E

E

E

E

E

E

"x

4"

"x 4" 12

"x 4"

"x

4"

"x

4"

12"x4"12"x4"

LIMITS OF DATA CABLING REPLACEMENT

FROM ROOM 015

12" LADDER

"x

4"

F2

"x

4"

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:3

:0

P

M

29-TN120

SECOND FLOOR PLAN -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1/8" = 1'-0"

SECOND FLOOR PLAN - TELECOMMUNICATIONS

N

0 8' 16'4'

GENERAL NOTES:

A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.

SHEET NOTES:

1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.

PENTHOUSE

ATTIC

B29-ATTIC

3D E

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:3

:0

P

M

29-TN130

ATTIC FLOOR PLAN -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1/8" = 1'-0"

THIRD FLOOR PLAN - TELECOMMUNICATIONS

P2 P11A

TOILET

MALE

LOCKER

C0C

CORRIDOR

XFMR

STOR AGE

20D

STOR AGE

20C

STOR AGE

OT/ LOW

VISION

STOR AGE

20A

STAIR

HALL

ENG

STOR AGE

MAS

STOR AGE

MALE

BATHR OOM

AUD IOLOGY

RECEP/W AITING

STOR AGE

20B

HAC

22FEMALE

LOCK ER

STOR

PIPE

CHASE

VESTI BULE

19 TOILET

19H

CORR

C0C

TOILET

1A

TANK ROOM

STOR AGE

20E

WAITING

6A

STAIR

STAIR

026 STOR AGE

REC EPTI ON /

SEC R ET AR Y

19A

OF FI C E

19B

MEC H ANI C AL

19W

AD MI N

OF F IC ER

19C

EXAM

19V

RECEPTION/

SIGN-OUT

5A

EXA M

5G

OFFICE

5I

OFFICE

5J

OFFICE

5K

FITTING

5H

EXA M

5C

AUX.

ROOM

5B

EXA M

5E

SUB

WAITING

5L

EXA M

5F

MULTI

PUR POSE

5D

CLEAN

STOR AGE

6B

EXAM

19U

EXAM

19T

EXAM

19S

EXAM

19I

EXAM

19J

EXAM

19K

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

F

IR

E

ACCESS PANEL

EXISTING GLYCOL TANK

EXISTING PUMPS/ EQUIPMENT

P2 P11A

TOILET

MALE

LOCKER

C0C

CORRIDOR

XFMR

STOR AGE

20D

STOR AGE

20C

STOR AGE

OT/ LOW

VISION

STOR AGE

20A

STAIR

HALL

ENG

STOR AGE

MAS

STOR AGE

MALE

BATHR OOM

AUD IOLOGY

RECEP/W AITING

STOR AGE

20B

HAC

22FEMALE

LOCK ER

STOR

PIPE

CHASE

VESTI BULE

19 TOILET

19H

CORR

C0C

TOILET

1A

TANK ROOM

STOR AGE

20E

WAITING

6A

STAIR

STAIR

026 STOR AGE

REC EPTI ON /

SEC R ET AR Y

19A

OF FI C E

19B

MEC H ANI C AL

19W

AD MI N

OF F IC ER

19C

EXAM

19V

RECEPTION/

SIGN-OUT

5A

EXA M

5G

OFFICE

5I

OFFICE

5J

OFFICE

5K

FITTING

5H

EXA M

5C

AUX.

ROOM

5B

EXA M

5E

SUB

WAITING

5L

EXA M

5F

MULTI

PUR POSE

5D

CLEAN

STOR AGE

6B

EXAM

19U

EXAM

19T

EXAM

19S

EXAM

19I

EXAM

19J

EXAM

19K

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

EXAM

19V

F

IR

E

ACCESS PANEL

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:3

:0

P

M

29-TN200

BASEMENT FLOOR PLAN -

TELECOM - CABLE DISTANCE

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

N

0 30' 60'15' 1" = 30'-0"

BASEMENT FLOOR PLAN - TELECOM - CABLE DISTANCE

C

F

UCF

U C

F

U C

F

REF.

F E

C

F E

C

F E

C

FEC

F E

C

FEC

113A

C1C

C1W

113B

123 132 134

142A

C1E

143A

167 154

149151

146142140

130129

163 165

161 164

162159

157 160

155 158

153 156

C7

C6

127128

126 125

114 115

C2

107106

104 105

103102

101100

C1

C le a n

U tility

B la n k e t W a rm e r

REF.

U C

F

UCF

U C

F

U C

F

REF.

F E

C

F E

C

F E

C

FEC

F E

C

FEC

113A

C1C

C1W

113B

123 132 134

142A

C1E

143A

167 154

149151

146142140

130129

163 165

161 164

162159

157 160

155 158

153 156

C7

C6

127128

126 125

114 115

C2

107106

104 105

103102

101100

C1

C le a n

U tility

B la n k e t W a rm e r

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:3

:1

P

M

29-TN210

FIRST FLOOR PLAN -

TELECOM - CABLE DISTANCE

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

N

0 30' 60'15' 1" = 30'-0"

FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE

STORAGESTORAGE

AC

CR

C

29-TN400

1 - a b

1 - c d

FAPS

AC

SP

TW

SP

E

E

E

E

E

TELECOM ROOM

DATA

RACK

CABLE

TRAY

C5 126"

KEYPAD

W

E

4"

12"x4"

E

R

DATA

RACK

DATA

RACK

DATA

RACK

"x

4"

"x

4"

12"x4"

12"x4"

NOTES:

1. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.

2. COORDINATE EXACT RACK COUNT AND LOCATION WITH OWNER PRIOR TO PERMANENT INSTALLATION.

3. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL RACK COMPONENTS.

4. RACK ELEVATION SHOWS A FULLY CONFIGURED SAMPLE RACK. CONTRACTOR TO PROVIDE REQUIRED EQUIPMENT TO

SUPPORT THE FINAL DATA COUNT FROM THE ENLARGED NEW SHEET. (NOT TO EXCEED 288 PORTS PER RACK).

5. COORDINATE FINAL RACK COMPONENT LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.

6. CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE COUNT, QUANTITY OF PATCH PANELS, SWITCHES, FIBER ENCLOSURES, BLANKING PANELS, CABLE MANAGEMENT, AND MOUNTING HARDWARE NOT MARKED AS “OIT PROVIDED”.

7. PUNCHDOWN COPPER BACKBONES ON RACK MOUNT PATCH PANELS. TERMINATE ONE (1) PAIR PER PATCH PANEL PORT.

VERTICAL CABLE

MANAGEMENT (TYP)

RACK 1

1U 144 STRAND OM4 AND OS2 DISTRIBUTION PANEL

1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)

1U 48 PORT CAT5E BACKBONE PATCH PANEL

1U CABLE MANAGEMENT

1U CABLE MANAGEMENT

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

6U 5KW RACK MOUNT UPS

V E

R T

IC

A

L R

A C

K P

D U

V E

R T

IC

A

L R

A C

K P

D U

NEMA L21-20R (TYP)

CHANNEL RACK (TYP)

D

PROVIDE DATA CABLE TO RACK

MOUNTED UPS FOR CONNECTION

TO MONITORING SYSTEM

RACK 1

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

1U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

6U 5KW RACK MOUNT UPS

V E

R T

IC

A

L R

A C

K P

D U

V E

R T

IC

A

L R

A C

K P

D U

NEMA L21-20R (TYP)

D

RACK 2

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

1U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

6U 5KW RACK MOUNT UPS

V E

R T

IC

A

L R

A C

K P

D U

V E

R T

IC

A

L R

A C

K P

D U

NEMA L21-20R (TYP)

D

RACK 3

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

1U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

RACK 2 RACK 3

6U SPACE FOR FUTURE USE. PROVIDE BLANK

PANELS FOR UNUSED SPACES.

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

SPACE FOR FUTURE HORIZONTAL CABLE

DISTRIBUTION. PROVIDE BLANKING PANELS FOR

UNUSED SPACES.

6U SPACE FOR FUTURE USE. PROVIDE BLANK

PANELS FOR UNUSED SPACES.

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

SPACE FOR FUTURE HORIZONTAL CABLE

DISTRIBUTION. PROVIDE BLANKING PANELS FOR

UNUSED SPACES.

6U SPACE FOR FUTURE USE. PROVIDE BLANK

PANELS FOR UNUSED SPACES.

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

SPACE FOR FUTURE HORIZONTAL CABLE

DISTRIBUTION. PROVIDE BLANKING PANELS FOR

UNUSED SPACES.

1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

6U 5KW RACK MOUNT UPS

V E

R T

IC

A

L R

A C

K P

D U

V E

R T

IC

A

L R

A C

K P

D U

NEMA L21-20R (TYP)

D

RACK 3

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

1U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

RACK 3

6U SPACE FOR FUTURE USE. PROVIDE BLANK

PANELS FOR UNUSED SPACES.

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

SPACE FOR FUTURE HORIZONTAL CABLE

DISTRIBUTION. PROVIDE BLANKING PANELS FOR

UNUSED SPACES.

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:3

:1

P

M

29-TN400

ENLARGED PLANS -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

N

0 2' 4'1'

0 4' 8'2' 0 4' 8'2' 0 4' 8'2' 0 4' 8'2'

CABLING NOTE:

CABLING NOTES:

A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.

THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED

FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE

PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.

1. ROOM 15

EXISTING CABLE COUNT

DATA (CAT6): 0

DATA (CAT5e): 460

DATA (CAT5): 0

DATA (CAT3): 0

CABLE RELOCATION COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

EXISTING CABLE TO REMAIN

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

FINAL CABLE COUNT

DATA (CAT6A): 460

DATA (CAT6): 0

1/2" = 1'-0"

ENALRGED PLAN - TR 15 - TELECOM

1/4" = 1'-0"

1 - a 1/4" = 1'-0"

1 - b

1/4" = 1'-0"

1 - c

1/4" = 1'-0"

1 - d

NOT TO SCALE

COMMUNICATIONS - TYPICAL FOUR RACK ELEVATION WITH RACK MOUNT UPS - TR 15

AC

CR

C

29-TN400

1 - a b

1 - c d

29-TN401

2 - a

29-TN401

b

29-TN401

d

29-TN401

2 - c

TELECOM ROOM

KEYPAD

W

24"x4"

DATA

RACK

CABLE

TRAY

12"x4"

"x

4"

"x

4"

12"x4"

C5 126"

DATA

RACK

NOTES:

1. REFER TO NEW WORK…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .