Atch 12 22-215Y BD Dwgs _Part2.pdf
PDF 2 MB Posted
- Solicitation number
- 36C24926R0064
About this file
These are bid documents for a video surveillance security improvement project at the Alvin C. York Campus (Murfreesboro VA Medical Center) in Murfreesboro, Tennessee. The project, designated VA Project Number 22-215 with ACG Project Number 626A4-22-104, consists of technology site plans and building security plans prepared by Apogee Consulting Group, P.A. for the U.S. Department of Veterans Affairs, Office of Construction and Facilities Management.
The scope of work includes demolishing existing cameras and cabling, installing new cameras with updated positioning throughout the campus, and running new four-pair unshielded twisted pair (4 PR UTP) cabling from cameras to designated IT equipment rooms in Buildings 1, 2, 3, 4, 8, 9, 117, and 120. Key technical requirements specify that all exterior cameras must be weatherproof, 270-degree cameras must be mounted directly on building corners, new CCTV cabling must be run on J-hooks spaced 2 feet on center above ceilings in corridors, and conduit must be a minimum of 3/4 inch. For camera runs exceeding 295 feet, fiber optic cable is required. Exterior conduit must be painted to match building colors prior to rough-in. The contractor must maintain active CCTV services outside construction areas, coordinate all new camera locations with the Contracting Officer's Representative prior to rough-in, and coordinate mounting heights with interior ceiling heights to minimize exterior conduit runs. Removed cameras and equipment must be turned over to the police department. The construction documents are dated June 13, 2024.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H6 N #133
WP
H6 N #139
WP
H6
RP
#140
WP
H6
RP
#141
WP
H6 N #134
WP
H6
RP
#137
WP
H6
RP
#138
WP
H6 N #135
WP
N #132
WP
H6 N #136
WP
N #107
WP
H6 N #111
WPH6
N #110
WP
H6 N #112
WP
FIXED
RV
WP
H6 N #109
WP
H6 N #97
WP
N #95
WP
N #94
WP
H6 N #96
WP
BLDG 6
RM 'G25'
BLDG 6
RM 'G25'
BLDG 6
RM 'G25'
BLDG 6
RM 'G25'
BLDG 5
RM '115'
BLDG 5
RM '115'
BLDG 5
RM '115'
BLDG 5
RM '115'
BLDG 7
RM '102'
BLDG 7
RM '102' BLDG 7
RM '102'
BLDG 7
RM '102'
BLDG 7
RM '102' BLDG 7
RM '102'
BLDG 7
RM '102'
BLDG 7
RM '102'
BLDG 7
RM '102'
BLDG 7
RM '102'
3 3
FIXED
RV
WP
2 5
N #108
WPBLDG 6
RM 'G25'
BLDG 6
RM 'G25'
1 1
IRM SERVER ROOM "115"
TR ROOM "G25"
TR ROOM "102"
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:2
:1
P
M C
U s e rs
\l s ta rn e s \D o c u m e n ts
\E -2
-2
Y
-V A
Y o rk
-V id e o S e c I m p ro v -T
N ls ta rn e s C
B U
M B
.r v t
TS101
TECHNOLOGY SITE PLAN
2 26LAS
VIDEO SURVEILLANCE
SECURITY YORK
ALVIN C. YORK CAMPUS
3400 LEBANON ROAD
MURFREESBORO, TN 37129 JUNE 13, 2024
BID DOCUMENTS
626A4-22-10422-215
JVE
1 EXISTING CAMERA APPROXIMATELY 12 FEET AFG
TO BE REMOVED AND REPLACED WITH NEW
CAMERA.
2 PROVIDE CORNER MOUNT BRACKET.
3 PROVIDE FLAT WALL BRACKET.
5 LENS OF MULTISENSOR CAMERA TO BE
DIRECTED TO COVER ENTRANCE OF BUILDING.
Scale: 1" = 110'-0"
SITE PLAN - MURFREESBORO VAMC - NORTH
A. DEMOLISH CAMERAS AS NOTED (SEE CAMERA
ABBREVIATIONS). REMOVE CABLING AND
CONDUIT BACK TO SOURCE. PATCH/REPAIR
AND PAINT SURFACES AFFECTED BY
DEMOLITION TO MATCH SURROUNDING AREA.
REPLACE ANY CEILING TILES DAMAGED OR
BROKEN DURING DEMOLITION AT NO
ADDITIONAL COST TO THE VA.
B. PROVIDE AND INSTALL NEW CAMERAS AS
NOTED (SEE CAMERA ABBREVIATIONS). RUN
NEW 4 PR UTP TO CCTV EQUIPMENT IN
DESIGNATED IT ROOM.
C. REMOVE AND REPLACE CAMERAS AS NOTED
(SEE CAMERA ABBREVIATIONS). RUN NEW 4 PR
UTP TO CCTV EQUIPMENT IN DESIGNATED IT
ROOM.
D. CCTV SERVICES ARE TO REMAIN ACTIVE
OUTSIDE AREAS UNDER ACTIVE
CONSTRUCTION AT ALL TIMES. FIELD VERIFY
CIRCUITS SHOWN AND RETAIN SERVICES TO
ALL DEVICES AND/OR SYSTEMS DURING
DEMOLITION AND REMODEL OF THE
RESPECTIVE AREAS.
E. ALL EXISTING CONDITIONS AND DEVICES ARE
BASED ON THE BEST AVAILABLE INFORMATION
AT THE TIME OF SURVEY AND VISUAL
INSPECTION. VERIFY EXISTING CONDITIONS IN
FIELD.
F. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'
OC ABOVE CEILING IN CORRIDORS.
G. ALL CONDUIT SECURITY JUNCTION BOXES AND
RACEWAY PROVIDED BY ELECTRICAL
CONTRACTOR UNO. ALL CONDUIT SHALL BE
3/4" MINIMUM. ELECTRICAL CONTRACTOR TO
SIZE CONDUIT PER THE MOST CURRENT
EDITION OF THE NEC.
H. ALL EXPOSED BOXES AND PANELS MOUNTED
ON OR IN THE EXTERIOR WALLS SHALL BE
WEATHERPROOF AND RAIN-TIGHT.
I. WHERE LENGTH FROM CAMERA TO RACK
EQUIPMENT EXCEEDS 295' (90M) CONTRACTOR
SHALL USE FIBER OPTIC CABLE.
J. ALL CAMERAS AND EQUIPMENT THAT IS
REMOVED SHALL BE TURNED OVER TO THE
POLICE DEPARTMENT. COORDINATE WITH
COR.
K. ALL EXTERIOR CAMERAS TO BE
WEATHERPROOF.
M. ALL EXTERIOR 270 DEGREE CAMERAS TO BE
MOUNTED DIRECTLY ON THE CORNERS OF THE
BUILDINGS.
N. CONTRACTOR SHALL PLAN PENETRATIONS
AND CONDUIT RUNS FROM EXTERIOR
CAMERAS INTO THE BUILDINGS SO AS TO
MINIMIZE THE CHANGES TO THE BUILDINGS
EXTERIOR AND WILL MINIMIZE THE NECESSARY
CONDUIT RUNS ON THE EXTERIOR OF THE
BUILDING.
O. COORDINATE EXTERIOR CAMERA MOUNTING
HEIGHT WITH THE INTERIOR CEILING HEIGHT
TO MINIMIZE EXTERIOR CONDUIT RUNS. REUSE
EXISTING CONDUIT RUNS AND BUILDING
PENETRATIONS WHEN POSSIBLE.
P. COORDINATE ALL NEW CAMERA LOCATIONS
WITH COR PRIOR TO ROUGH-IN.
Q. ALL CONDUIT RUNS ON THE EXTERIOR OF THE
BUILDING SHALL BE PAINTED TO MATCH THE
BUILDING COLOR PRIOR TO ROUGH-IN.
N O
R T
H
0 3015 60
Docusign Envelope ID: B9B77CD2-F0C1-4BAA-8538-6B315B443E44
7/24/2024
H6 N #157
WP
H6 N #191
WP
H6 N #192
WP
H6 N #193
WP
N #189
WP
H6 N #194
WP
H6 N #195
WP
H6 N #196
WP
H6 N #197
WP
H6 N #198
WP
H6 N #199
WP
RP
#190
WP
H6 N #37
WP
H6 N #38
WP
H6 N #39
WP
RP
#36
WP
H6 N #40
WP
H6 N #41
WP
H6 N #42
WPH6
N #74
WP
H6 N #75
WP
H6 N #76
WP
H6 N #77
WP
H6 N #78
WP
H6 N #79
WP
N #71
WP
RP
#72
WP
N #73
WP
N #236
WP
N #17
WP
N #16
WP
N #18
WP
H6 N #21
WP
N #19
WP
H6 N #22
WP
RP
#20
WP
H6 N #160
WP
N #156
WP
H6 N #158
WP
H6 N #159
WP
H6 N #89
WP
H6 N #90
WP
H6 N #91
WPH6
N #88
WP
H6 N #92
WP
BLDG 4
RM 'G112A'
BLDG 4
RM 'G112A'
BLDG 4
RM 'G112A'
BLDG 4
RM 'G112A'
BLDG 4
RM 'G112A'
BLDG 3
RM 'G03A'
BLDG 3
RM 'G03A'
BLDG 3
RM 'G03A'
BLDG 3
RM 'G03A'
BLDG 3
RM 'G03A'
BLDG 3
RM 'G03A'
BLDG 3
RM 'G03A'
BLDG 3
RM 'G03A'
BLDG 2
RM 'G20A'
BLDG 2
RM 'G20A'
BLDG 2
RM 'G20A'
BLDG 2
RM 'G20A'
BLDG 2
RM 'G20A'
BLDG 2
RM 'G20A'
BLDG 2
RM 'G20A'
BLDG 117
RM 'G63'
BLDG 1
RM '106A'
BLDG 1
RM '106A'
BLDG 1
RM '106A'
BLDG 1
RM '106A'
BLDG 1
RM '106A'
BLDG 1
RM '106A'
BLDG 9
RM '127'
BLDG 9
RM '127'
BLDG 9
RM '127'BLDG 9
RM '127'
BLDG 9
RM '127'
BLDG 9
RM '127'
BLDG 9
RM '127'
BLDG 9
RM '127'
BLDG 9
RM '127'
BLDG 8
RM '143'
BLDG 8
RM '143'
BLDG 8
RM '143'
BLDG 8
RM '143'
BLDG 8
RM '143'
1 2
1 21 2
1 22
BLDG 9
RM '127'
BLDG 3
RM 'G03A'
BLDG 1
RM '106A'
BLDG 9
RM '127'
TR RM '106A'
TR RM 'G20A'
TR RM 'G03A'
TR RM 'G112A'
TR RM '143'
TR RM 'G63'
RP
#241
WP
BLDG 120
RM 'G02'
2 H6 N #242
WP
BLDG 120
RM 'G02'
BLDG 120
RM 'G02'
RP
#240
WP
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:2
:4
P
M C
U s e rs
\l s ta rn e s \D o c u m e n ts
\E -2
-2
Y
-V A
Y o rk
-V id e o S e c I m p ro v -T
N ls ta rn e s C
B U
M B
.r v t
TS102
TECHNOLOGY SITE PLAN
3 26LAS
VIDEO SURVEILLANCE
SECURITY YORK
ALVIN C. YORK CAMPUS
3400 LEBANON ROAD
MURFREESBORO, TN 37129 JUNE 13, 2024
BID DOCUMENTS
626A4-22-10422-215
JVE
Scale: 1" = 110'-0"
SITE PLAN - MURFREESBORO VAMC - SOUTH
1 EXISTING CAMERA APPROXIMATELY 12 FEET AFG
TO BE REMOVED AND REPLACED WITH NEW
CAMERA.
2 PROVIDE CORNER MOUNT BRACKET.
3 PROVIDE FLAT WALL BRACKET.
4 REPLACE CAMERA AT ENTRANCE UNDER
OVERHANG.
5 LENS OF MULTISENSOR CAMERA TO BE
DIRECTED TO COVER ENTRANCE OF BUILDING.
A. DEMOLISH CAMERAS AS NOTED (SEE CAMERA
ABBREVIATIONS). REMOVE CABLING AND
CONDUIT BACK TO SOURCE. PATCH/REPAIR
AND PAINT SURFACES AFFECTED BY
DEMOLITION TO MATCH SURROUNDING AREA.
REPLACE ANY CEILING TILES DAMAGED OR
BROKEN DURING DEMOLITION AT NO
ADDITIONAL COST TO THE VA.
B. PROVIDE AND INSTALL NEW CAMERAS AS
NOTED (SEE CAMERA ABBREVIATIONS). RUN
NEW 4 PR UTP TO CCTV EQUIPMENT IN
DESIGNATED IT ROOM.
C. REMOVE AND REPLACE CAMERAS AS NOTED
(SEE CAMERA ABBREVIATIONS). RUN NEW 4 PR
UTP TO CCTV EQUIPMENT IN DESIGNATED IT
ROOM.
D. CCTV SERVICES ARE TO REMAIN ACTIVE
OUTSIDE AREAS UNDER ACTIVE
CONSTRUCTION AT ALL TIMES. FIELD VERIFY
CIRCUITS SHOWN AND RETAIN SERVICES TO
ALL DEVICES AND/OR SYSTEMS DURING
DEMOLITION AND REMODEL OF THE
RESPECTIVE AREAS.
E. ALL EXISTING CONDITIONS AND DEVICES ARE
BASED ON THE BEST AVAILABLE INFORMATION
AT THE TIME OF SURVEY AND VISUAL
INSPECTION. VERIFY EXISTING CONDITIONS IN
FIELD.
F. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'
OC ABOVE CEILING IN CORRIDORS.
G. ALL CONDUIT SECURITY JUNCTION BOXES AND
RACEWAY PROVIDED BY ELECTRICAL
CONTRACTOR UNO. ALL CONDUIT SHALL BE
3/4" MINIMUM. ELECTRICAL CONTRACTOR TO
SIZE CONDUIT PER THE MOST CURRENT
EDITION OF THE NEC.
H. ALL EXPOSED BOXES AND PANELS MOUNTED
ON OR IN THE EXTERIOR WALLS SHALL BE
WEATHERPROOF AND RAIN-TIGHT.
I. WHERE LENGTH FROM CAMERA TO RACK
EQUIPMENT EXCEED 295' (90M) CONTRACTOR
SHALL USE FIBER OPTIC CABLE.
J. ALL CAMERAS AND EQUIPMENT THAT IS
REMOVED SHALL BE TURNED OVER TO THE
POLICE DEPARTMENT. COORDINATE WITH
COR.
K. ALL EXTERIOR CAMERAS TO BE
WEATHERPROOF.
M. ALL EXTERIOR 270 DEGREE CAMERAS TO BE
MOUNTED DIRECTLY ON THE CORNERS OF THE
BUILDINGS.
N. CONTRACTOR SHALL PLAN PENETRATIONS
AND CONDUIT RUNS FROM EXTERIOR
CAMERAS INTO THE BUILDINGS SO AS TO
MINIMIZE THE CHANGES TO THE BUILDINGS
EXTERIOR AND WILL MINIMIZE THE NECESSARY
CONDUIT RUNS ON THE EXTERIOR OF THE
BUILDING.
O. COORDINATE EXTERIOR CAMERA MOUNTING
HEIGHT WITH THE INTERIOR CEILING HEIGHT
TO MINIMIZE EXTERIOR CONDUIT RUNS. REUSE
EXISTING CONDUIT RUNS AND BUILDING
PENETRATIONS WHEN POSSIBLE.
P. COORDINATE ALL NEW CAMERA LOCATIONS
WITH COR PRIOR TO ROUGH-IN.
Q. ALL CONDUIT RUNS ON THE EXTERIOR OF THE
BUILDING SHALL BE PAINTED TO MATCH THE
BUILDING COLOR PRIOR TO ROUGH-IN.
N O
R T
H
0 3015 60
BUILDING 1BUILDING 120
BUILDING 1
BUILDING 117
2 2
RM 'A-17A'
RM '106A'
RM 'G63'
N #1
H6SL
N #6
SW
N #7
H6 N #4
N #2
N #3
SW
N #8
H6 N #5
RM '106A'
RM '106A'
RM '106A'
RM '106A'
RM '106A'
RM '106A'
RM '106A'
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:2
:5
P
M C
U s e rs
\l s ta rn e s \D o c u m e n ts
\E -2
-2
Y
-V A
Y o rk
-V id e o S e c I m p ro v -T
N ls ta rn e s C
B U
M B
.r v t
1.T-101
BUILDING 1 GROUND FLOOR SECURITY
PLAN
4 26LAS
VIDEO SURVEILLANCE
SECURITY YORK
ALVIN C. YORK CAMPUS
3400 LEBANON ROAD
MURFREESBORO, TN 37129 JUNE 13, 2024
BID DOCUMENTS
626A4-22-10422-215
JVE
Scale: 3/32" = 1'-0"
BUILDING 1 GROUND FLOOR SECURITY PLAN
1 ROUTE UTP CABLING UP TO TELECOM ROOM
ABOVE.
2 INSTALL NEW CAMERAS. PROVIDE NEW 4 PR
UTP CABLING FROM CAMERA TO NEW POE
SWITCH IN TELECOM ROOM. REPAIR/
REPLACE SURFACES AFFECTED BY CAMERA
EQUIPMENT INSTALLATION TO MATCH
SIMILAR/EXISTING CONDITIONS.
CONTRACTOR TO REPLACE DAMAGED
CEILING TILE AND GRID ASSOCIATED WITH
WORK AT NO ADDITIONAL COST TO
GOVERNMENT.
A. REFERENCE SHEET TS101 AND TS102 FOR
EXTERIOR CAMERA LOCATIONS.
B. ALL EXISTING CONDITIONS ARE BASED ON THE
BEST AVAILABLE INFORMATION AT THE TIME
OF SURVEY.
C. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'
OC ABOVE CEILING IN CORRIDORS.
D. ALL CONDUIT SHALL BE 3/4" MINIMUM.
ELECTRICAL CONTRACTOR TO SIZE CONDUIT.
PER THE MOST CURRENT EDITION OF THE NEC.
E. WHERE LENGTH FROM CAMERA TO RACK
EQUIPMENT EXCEEDS 295' (90M) CONTRACTOR
SHALL USE FIBER OPTIC CABLE.
F. COORDINATE AND CONFIRM ALL ROUTING
WITH COR PRIOR TO ROUGH-IN.
G. SEE SHEET G-100 FOR ICRA MEASURES.
H. USE MOBILE CONTAINMENT CART (6/G-100)
ALONG CORRIDORS.
N O
R T
H
0 84 16
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
TR ROOM 106A:
3 PR SPARE MMF1 2 3 4
1 2
RP
#10
FIXED
RV
FIXED
RV
H6 N #13
SW
N #15
N #11
H6 N #14
RM '106A'
RM '106A'
RM '106A'
RM '106A'
BUILDING 1BUILDING 120
BUILDING 1
BUILDING 117
BUILDING
BUILDING 117
BUILDING 1
RM '106A'
H5A FE
N #9
RP
#12
RM '106A'
RM '106A'
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:2
:0
P
M C
U s e rs
\l s ta rn e s \D o c u m e n ts
\E -2
-2
Y
-V A
Y o rk
-V id e o S e c I m p ro v -T
N ls ta rn e s C
B U
M B
.r v t
1.T-102
BULIDING 1 FIRST FLOOR SECURITY
PLAN
5 26LAS
VIDEO SURVEILLANCE
SECURITY YORK
ALVIN C. YORK CAMPUS
3400 LEBANON ROAD
MURFREESBORO, TN 37129 JUNE 13, 2024
BID DOCUMENTS
626A4-22-10422-215
JVE
Scale: 3/32" = 1'-0"
BUILDING 1 FIRST FLOOR SECURITY PLAN
1 REMOVE EXISTING CAMERAS AND CABLING
BACK TO SOURCE. REPAIR/REPLACE
EXISTING SURFACES AFFECTED BY
REMOVAL OF CAMERA EQUIPMENT TO
MATCH SIMILAR EXISTING CONDITIONS.
2 INSTALL NEW CAMERAS. PROVIDE NEW 4 PR
UTP CABLING FROM CAMERA TO NEW POE
SWITCH IN TELECOM ROOM. REPAIR/
REPLACE SURFACES AFFECTED BY CAMERA
EQUIPMENT INSTALLATION TO MATCH
SIMILAR/EXISTING CONDITIONS.
CONTRACTOR TO REPLACE DAMAGED
CEILING TILE AND GRID ASSOCIATED WITH
WORK AT NO ADDITIONAL COST TO
GOVERNMENT.
3 PROPOSED LOCATION OF NEW CISCO 9300
SWITCH AND PATCH PANEL. VERIFY
LOCATION WITH COR AND OIT
REPRESENTATIVE.
4 ROUTE MMF FROM TELECOM ROOM TO
RACKS IN BUILDING 5 SERVER ROOM.
N O
R T
H
0 84 16
A. REFERENCE SHEET TS101 AND TS102 FOR
EXTERIOR CAMERA LOCATIONS.
B. ALL EXISTING CONDITIONS ARE BASED ON THE
BEST AVAILABLE INFORMATION AT THE TIME
OF SURVEY.
C. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'
OC ABOVE CEILING IN CORRIDORS.
D. ALL CONDUIT SHALL BE 3/4" MINIMUM.
ELECTRICAL CONTRACTOR TO SIZE CONDUIT.
PER THE MOST CURRENT EDITION OF THE NEC.
E. WHERE LENGTH FROM CAMERA TO RACK
EQUIPMENT EXCEEDS 295' (90M) CONTRACTOR
SHALL USE FIBER OPTIC CABLE.
F. COORDINATE AND CONFIRM ALL ROUTING
WITH COR PRIOR TO ROUGH-IN.
G. SEE SHEET G-100 FOR ICRA MEASURES.
H. USE MOBILE CONTAINMENT CART (6/G-100)
ALONG CORRIDORS.
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
| 22-215YELEC |
| Sheets |
| 1.T-101 - BUILDING 1 GROUND FLOOR SECURITY PLAN |
| 1.T-102 - BULIDING 1 FIRST FLOOR SECURITY PLAN |
| TS101 - TECHNOLOGY SITE PLAN |
| TS102 - TECHNOLOGY SITE PLAN |
File details come from the government source that posted it. Updated .