Appendix A SOW - 554-26-105 Replace Damaged Windows.xlsx
XLSX spreadsheet 10 MB Posted
- Solicitation number
- 36C25926R0028
About this file
This document is an Appendix A Statement of Work (SOW) detailing window replacement specifications for the Rocky Mountain Regional VA Medical Center in Aurora, Colorado. The comprehensive replacement project involves 20 windows and 4 doors across multiple building locations, including specific rooms like K1-224, F1-249, B2-121B, and various corridors and vestibules. The windows vary in size, ranging from 34"x66" to 84"x124", and include specifications such as 1 1/4" low-e insulated glass, 7/16" laminated spandrel, and 9/16" clear laminated types.
The project requires careful coordination with medical facility operations to minimize disruption, with specific points of contact including Tina Collins, Maintenance Staff, and Pam Rice. Contractors must validate window types with the Contracting Officer's Representative (COR) before ordering and adhere to strict safety requirements, including having a Competent Person with a 30-hour OSHA card on-site and ensuring all employees have at least 10-hour OSHA construction safety training certificates. The work must conform to VA standards, OSHA regulations, AIA Construction Guidelines, Joint Commission Environment of Care Standards, and applicable building codes.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Item # | Room Number | Glass size / Description | Notes | ICRA notes | POC |
| 1 | K1-224 - Rehab Gym | 38"x98" - 1 1/4" low-e, insulated | biomed move equipment? | Tina Collins | |
| 2 | K1-224 - spandrel | 38"x98" - 7/16" laminated spandrel | Tina Collins | ||
| 3 | K1-137 | 48"x96" - 7/16" laminated spandrel | Tina Collins | ||
| 4 | F1/H1 Corridor | 48"x66" - 1 1/4" low-e, insulated | Tina Collins / Maint Staff | ||
| 5 | F1/H1 Corridor | 47"x65" - 1 1/4" low-e, insulated | Tina Collins / Maint Staff | ||
| 6 | H1-117 | 47"x95" - 1 1/4" low-e, insulated | Tina Collins | ||
| 7 | CON/H2 Interior door | 42"x 99" - 1/2"Lam Glass door | use existing hardware? | Maint Staff | |
| 8 | CON @ H2 hall glass | 72"x118" 9/16" frosted/laminated | overnight/after hours | Maint Staff | |
| 9 | CON/H3 Interior door | 42"x 99" - 1/2"Lam Glass door | use existing hardware? | Maint Staff | |
| 10 | CON /F3 - top pane | 84"x84" 9/16" frosted/laminated | overnight/after hours | Maint Staff | |
| 11 | F1-249 | 47"x89" - 1 1/4" low-e, insulated | |||
| 12 | F1-249 - spandrel | 48"x124" - 7/16" laminated spandrel | |||
| 13 | CON L2 @ Bldg B - top | 36"x120" - 1 1/4" low-e, insulated | Maint Staff | ||
| 14 | CON L2 @ Bldg B - bottom | 48"x54" - 1 1/4" low-e, insulated | Maint Staff | ||
| 15 | B2-121B (#1) | 84"x72" - 1 1/4" low-e, insulated | Solar Tubes | Pam Rice? | |
| 16 | B2-121B (#2) | 84"x72" - 1 1/4" low-e, insulated | Solar Tubes | Pam Rice? | |
| 17 | B2-121B (#3) | 84"x72" - 1 1/4" low-e, insulated | Solar Tubes | Pam Rice? | |
| 18 | CON @ Colfax vestibule | 66"x34" - 1 1/4" low-e, insulated | Maint Staff | ||
| 19 | A1-201 Door | 8' storefront door Lam/Low-e | |||
| 20 | A4-209 | 8' storefront door Lam/Low-e | |||
| 21 | D2 courtyard @ D2-105 | 48"x96" - 1 1/4" low-e, insulated | |||
| 22 | PSN NE Stair @ L3-4 | 49"x120" - 9/16 clear laminated | Maint Staff | ||
| 23 | PSN Elev Lobby | 45"x108" - 9/16 clear laminated | Maint Staff | ||
| 24 | Ped Bridge | 52"x80" (irregular) - 9/16 clear laminated | Above 17th Ave - closure necessary? | Maint Staff |
image1.png image10.png image11.png image12.png image13.png image14.png image15.png image16.png image17.png image18.png image19.png image2.png image20.png image21.png image22.png image23.png image24.png image25.png image26.png image27.png image28.png image3.png image4.png image5.png image6.png image7.png image8.png image9.png
File details come from the government source that posted it. Updated .