This document is an architectural drawing set showing building sections for a concourse facility. The drawing depicts partial sections at a scale of 3/32" = 1'-0" and includes detailed as-built conditions current as of February 13, 2024. The document references a Clinic Building (South) and Research Building with associated structural and mechanical systems.

The drawing illustrates multi-story building sections with metal cladding, roof elements, and extensive interior structural framing including vertical supports and horizontal floor systems. The sections show ground-level clinic spaces with multiple doors and windows, mid-level research areas with repetitive structural bays, and upper-level mechanical/roof systems. Material callouts reference metal cladding components (4 1/2" EJC, 1/2" roof EJC), and the drawing includes a comprehensive materials legend on the right side. The document originates from architectural/engineering consultants and is prepared as current as-built conditions documentation for a healthcare facility in Aurora, Colorado. The file was created in Revit software and includes standard architectural drawing conventions with grid references, elevation markers, and professional consultant seals.

View the file

Other files

File Type Posted
RFI 554-26-105 Replace Damaged Windows 1 14 2026.pdf PDF
36C25926R0028 0003.pdf PDF
RFI 554-26-105 Replace Damaged Windows 1 14 2026.docx DOCX document
Bldg K IBN_Tractel_As-Builts.pdf PDF
11 24 24-022_PSN_As-Builts_Tractel_Stamped_Calcs.pdf PDF
03.AS.102-B Bldg F.D fp2.pdf PDF
02.AS.201 Bldg B elv.pdf PDF
01.AS.302 Conc elv.pdf PDF
01.AS.101-D Conc partial fp2.pdf PDF
36C25926R0028 0002.docx DOCX document
Appendix A SOW - 554-26-105 Replace Damaged Windows-rev1.xlsx XLSX spreadsheet
Concourse CON_Tractel _Stamped_Calcs.pdf PDF
Bldg F 11 24 24-022_DAT_As-Builts_Tractel.pdf PDF
Bldg B RES_Tractel_Davit_Arms_As-Builts.pdf PDF
01.AS.304 Conc elv cont2.pdf PDF
Site Visit document.docx DOCX document
Bldg K IBN_Stamped_Calcs.pdf PDF
Bldg F 11 24 24-022_DAT_As-Builts_Tractel_Stamped_Calcs.pdf PDF
03.AS.102-A Bldg F.D fp1.pdf PDF
Concourse CON_Tractel_As-Builts.pdf PDF
Bldg B RES_Tractel_Davit_Arms_Stamped_Calcs.pdf PDF
554-26-105 Replace Damaged Windows Sign-in sheet.pdf PDF
11 24 24-022_PSN_As Builts Tractel.pdf PDF
03.AS.202 - Bldg F to D Courtyard elv.pdf PDF
01.AS.101-C Conc partial fp1.pdf PDF
Instructions to Offerors.docx DOCX document
36C25926R0028 0001.docx DOCX document
RFR - 554-26-105 Replace Damaged Windows at RMRVAMC.pdf PDF
Past Performance Questionnaire_Blank.docx DOCX document
Prime and Sub Contractor Construction Breakdown.xlsx XLSX spreadsheet
Self-Performed and Subcontracted Worksheet.docx DOCX document
Appendix A SOW - 554-26-105 Replace Damaged Windows.xlsx XLSX spreadsheet
852.219-75 LOS Certification.docx DOCX document
36C25926R0028.docx DOCX document
ICRA- 554-26-105 Replace Damaged Windows.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

02-RESEARCH BUILDING

MWP01

LEVEL 1

100' - 0"

LEVEL 2

120' - 0"

LEVEL 3

140' - 0"

SERVICE LEVEL

80' - 0"

ROOF - CON

171' - 2"

01.AS.312

MTL73

MWP01

METAL

CLADDING

FRGW01

4 1/2"

EJC 12

4 1/2"

ROOF

EJC 01

LEVEL 1

100' - 0"

LEVEL 2

120' - 0"

LEVEL 3

140' - 0"

SERVICE LEVEL

80' - 0"

ROOF - CON

171' - 2"

MWP01

MTL73

METAL

CLADDING

10-CLINIC BUILDING

(SOUTH)

MATERIAL LEGEND

CODE

PC51

MATERIAL

PRECAST CONCRETE

PC61 PRECAST CONCRETE

ST51 STONE

ST52 STONE

MTL61 ALUMINUM - WHITE

MP51A CORRUGATED METAL WALL

PANEL

MP51

CORRUGATED METAL WALL

PANEL - INSULATED BACK-UP

MTL73 ALUMINUM - COPPER METALLIC

EPSS

PAINTED EXPOSED

STRUCTURAL STEEL

GL03 FIRE-RATED GLASS

GL61 LAMINATED GLASS

MTL51 MISCELLANEOUS METALS

STAINLESS STEEL

SST SECURITY MESHMTL52

GL62 BIPV LAMINATED GLASS

GL81 INSULATING LAMINATED

GLASS - CUSTOM FRIT

PC71 PRECAST CONCRETE

MP53 METAL PANEL SOFFIT

MP55 METAL WALL PANEL

MP61

CORRUGATED METAL WALL

PANEL

LVR51 BLAST LOUVER

LVR52 LOUVER

MP52 INSULATED METAL WALL

PANEL

INSULATED METAL WALL

PANEL

MP54

INSUL01

INSUL02

INSUL03

EXTRUDED POLYSTYRENE

HIGH-DENSITY EXTRUDED

POLYSTYRENE

MINERAL FIBER

INSULATION

GL82 MONOLITHIC SPANDREL

GLASS

GL52 INSULATING LAMINATED GLASS

W/ INTEGRAL HORIZ BLINDS

GL51 INSULATING LAMINATED GLASS

LVR53 BLAST LOUVER

MP52A UNINSULATED METAL WALL

PANEL

PC81 PRECAST CONCRETE

FRGW01 FIRE RATED GLAZING WALL

FRGD01 FIRE RATED GLAZING

DOOR

MTL01 MISCELLANEOUS METALS

GL04 LAMINATED GLASS

GL05 LAMINATED GLASS

INSULATING LAMINATED GLASS W/

INTEGRAL HORIZ BLINDS AND

LAMINATED OUTBOARD LITE

GL53

11 12 08 09 13

03040506

Drawing Number

Building Number

Project NumberProject Title

Location

Date Checked Drawn

Drawing Title

Approved: Project Director

Key Plan

CONSULTANTS:

DateRevisions

1 2 3 4 5 6 7 8 9 10 11 12

D

C

B

A

554-501REPLACEMENT MEDICAL CENTER

FACILITY, EASTERN COLORADO

HEALTH CARE SYSTEM

AURORA, COLORADO

N

C O

N

R E

S

D A

T

IB

S

IB

N

E N

C

C L C

C B

N

C B

C

C B

S

P S

N

P V

N

P V

S

13 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14

E th re e t h ir ty

-s e c o n d i n c h o n e f o o t

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT/ENGINEERS:

Professional Seal

THESE ARE THE MOST CURRENT AS-BUILT CONDITIONS AS OF:

/1

/2

:1

:0

P

M C

U s e rs \h a u n g

\D o c u m e n ts

\A S

-C E

N T

R A

L h a u n g

G

H V

P .r v t

2/13/2024 5:18:07 PM

01.AS.303

BUILDING SECTIONS

CONCOURSE

08/31/2012

3/32" = 1'-0"1

PARTIAL SECTION

3/32" = 1'-0"2

PARTIAL SECTION

Sheets
01.AS.303 - BUILDING SECTIONS

File details come from the government source that posted it. Updated .