01.AS.101-D Conc partial fp2.pdf
PDF 2 MB Posted
- Solicitation number
- 36C25926R0028
About this file
This document is an architectural floor plan depicting Level 1 of a facility with multiple functional areas. The plan shows as-built conditions as of February 28, 2024, and is presented at scales of 1 1/8" = 1'-0" for the Area Concourse section and 2 1/8" = 1'-0" for Areas E and F.
The facility contains diverse spaces organized across multiple zones. Area E includes administrative and security functions such as PES (likely Personnel Entry Screening) interview and observation rooms, security examination and toilet facilities, staff lockers and showers, and offices for chief and assistant chief positions. The concourse area incorporates public amenities including dining facilities (multiple dining areas labeled C1-110 through C1-114), an auditorium with associated storage and AV control facilities, seating areas, restrooms, and a family room. Additional spaces include interview and holding areas, workstations, vital sign stations, serving areas, and various support functions such as storage, information desks, and security desk locations. The plan references mechanical systems including an EKG alcove, heating/air conditioning (HAC) systems, and a snow melt system with details referenced in specification 14/XX.AS.562. Dimensions throughout the plan indicate structural bays ranging from 6'-0" to 30'-0" and various room-specific measurements. The document identifies consultants and architect/engineers involvement and includes professional seals for project authorization.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
UP
DN
FDFD
FDFD
UP
01-01-ST3
STAIR
C1-ST1
STAIR
01-01-ST5
CE-S01
ELEV
01-01-SE15
C1-C05
VEST
01-01-SB30-01
C1-127
LOBBY VEST
01-01-A30-10
C1-C03
CORRIDOR
01-01-A36-08
01-01-A32-12
VEST
C
D
B
A
D1-ST1
STAIR
03-01-ST3
03-01-A8-07
HALL
D1-168
PES INTERVIEW
03-01-A8-02
D1-173
HAC
03-01-A8-01
D1-166A
SECURITY TLT
03-01-A7-03
D1-166
PES OBSERV
03-01-A8-03
D1-138
PES INTERVIEW
03-01-A8-04
D1-140
EXAM
03-01-B8-01
D1-C12
CORRIDOR
03-01-B8-04
D1-171
STAFF
LOUNGE/LOCKERS
03-01-A9-01
D1-169
OFFICE
03-01-A8-05
D1-136
SECURITY EXAM
03-01-A8-06
D1-134
SECURITY TLT
03-01-A9-03
D1-132
SECURITY EXAM
03-01-A9-04 D1-130
PAT TLT
03-01-A9-07
D1-171A
STAFF
TLT/SHOWER
03-01-A9-02
D1-C07
CORRIDOR
03-01-B9-06
D1-128
EKG ALCOVE
03-01-A9-08
03-01-A10-01
VEST D1-100
SECRETARY/WAIT
03-01-A11-01
D1-C01
VEST
03-01-A11-03 D1-101
CHIEF OFFICE
03-01-A11-04
D1-102
STAFF TLT
03-01-A11-02
D1-103
ASST CHIEF
OFFICE
03-01-A11-05
03-01-A11-06
INV OFFICE
D1-104
INTERVIEW
03-01-B11-01
D1-106
HOLDING
03-01-B11-02
D1-C02
CORRIDOR
03-01-B11-08
D1-105
WORKSTATIONS
03-01-B11-05
D1-120
WAIT
03-01-B10-04 03-01-B11-09
CORRIDOR
D1-122
VITAL SIGN STN
03-01-A10-05
D1-123
VITAL SIGN STN
03-01-B10-01
D1-C06
CORRIDOR
03-01-A9-05
[NA] SHARES A
WAYF.# WITH
D1-135
PROVIDER WORK
03-01-B9-01D1-135
PES WORK
03-01-B8-02
D1-126
PSA
03-01-B9-02
E
.A
S .2
S E
E
.A
S .1
-C
S E
E
.A
S .1
-D
S38
SB
S37
S36
S35
S34
S33
S32
S31
S30
SA
01.AS.401
E16
E11
01.AS.306
01.AS.306
01.AS.306
01.AS.306
01.AS.306
01.AS.306
A
.A
S .2
.A
S .2
.A
S .2
.A
S .2
.A
S .2
.A
S .2
.A
S .2
30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"30'-0"
1'-5"5 PANELS @ 6'-0" TYP6'-0"3'-0"12'-0"3'-0"6'-0"1'-5"10'-10 1/4"6'-0"11'-8 3/4"
/8
/8
/8
/8
/8
/8
/8
/8
/2
E
Q P
A N
E L S
'-5
11'-6"2'-5 1/2"
/8
/8
8"
XX.AS.501
XX.AS.503
XX.AS.502
XX.AS.503
A
E13
E14
E17
K4
K4
K4
K4
K4
K4
K4S
K4
K4
K4
B4
K4
XX.AS.509
XX.AS.509
XX.AS.509
XX.AS.509
S34.6
SD
SC
S29.3
Z
SE
A
RS32
01.AS.302
01.AS.303
01.AS.303
01.AS.201
01.AS.202
XX.AS.503
XX.AS.503
XX.AS.503
SIM
XX.AS.501
XX.AS.503
B4
K4
/8
/2 "6
/8
7'-0"1'-2" 1'-2 1/8"7'-0"
K4
K4
/8
/2
2"9'-0"
'-1
/8
5'-5 1/2"
9 5/8"
/8
4 3/8"
G2 K4
B4
K4 K4
8'-4 3/8"11'-5 3/4"5 3/4"
1'-5" 15'-5 3/8" 31'-11 7/8" 32'-0 1/8" 32'-0" 18'-3 3/8" 18'-2 1/8" 8 1/4"
K4 K4
5 1/4" 1'-7 1/2"
/8
/8
EXTENT OF SNOW MELT
SYSTEM, REFER TO
14/XX.AS.562 FOR DET
XX.AS.501
'-4
'-1 " E
Q E
Q
6'-0 1/8" 6'-0 1/8"
6'-0 1/8" 6'-5 1/4"
5'-3"5"
XX.AS.503
14A
.A
S .2
XX.AS.510
E12
2'-0 1/4"
4'-0 1/2"
/2
XX.AS.507
XX.AS.507
XX.AS.507
XX.AS.507
OPEN TO
BELOW
OPEN TO
BELOW
OPEN TO
BELOW
OPEN TO
BELOW
4 1/2"
2'-2 1/2"
4 1/2" EJC 12
E15
'-8
C1-132
SEATING
01-01-A30-01
C1-130
SEATING
01-01-A31-07
C1-C06
PUBLIC
01-01-A30-09
C1-120
EXHIB DISPLAY
01-01-A32-01
C1-114
DINING
01-01-A34-01
C1-112
DINING
01-01-A35-01
C1-110
DINING
01-01-A36-01
C1-108
DINING
01-01-A37-01
C1-106
DINING
01-01-A38-01
C1-109
FAMILY RM
01-01-A37-02
C1-103
HAC
01-01-A37-04
C1-105
FEMALE TLT
01-01-A37-06
C1-107
MALE TLT
01-01-A37-05
C1-111
SERVING
01-01-A36-02
C1-111
SERVING
01-01-A36-02
C1-111B
NON-FOOD STOR
01-01-A37-08
C1-C02
PUBLIC
01-01-A34-06
C1-113
DINING
01-01-A34-03
C1-115; C1-117; C1-119; C1-125
AUDITORIUM
01-01-A32-05
C1-115C
AV CONTROL
01-01-A33-03
C1-115A
STOR
01-01-A33-04
01-01-A34-02
VEST C1-115B
STOR
01-01-A34-05
01-01-A34-04
VEST
01-01-A32-09
VEST
C1-117A
STOR
01-01-A33-0701-01-A33-06
STORC1-125A
STOR
01-01-A33-05
01-01-A32-11
VEST
C1-C04
VEST
01-01-A32-08
C1-123
W.C. STOR
01-01-A32-07
01-01-A32-06
STOR
01-01-A32-02
SECURITY STOR
C1-119A
STOR
01-01-A33-08
01-01-A32-03
VEST C1-119B
STOR
01-01-A33-02
C1-127
LOBBY VEST
01-01-A30-1001-01-A30-11
ELEV VEST
C1-135
MALE TLT
01-01-A30-05
C1-133
FEMALE TLT
01-01-A30-06
C1-137
VEND
01-01-A30-04
C1-131
HAC
01-01-A30-02
C1-C06
PUBLIC
01-01-A30-09 C1-129
OFFICE
01-01-A31-01
01-01-A31-03
INFO
01-01-A31-04
SECURITY DESK
C1-127
VEST SEATING
01-01-A31-06
C1-100
VEST
01-01-A41-01
A1-C29
CORR
10-01-12A.1-01
10-ST3
STAIR
C
D
B
A
B1-C01
CORRIDOR
02-01-A2-01
E
S E
E
.A
S .1
-D
01.AS.306
01.AS.306
E Q
'-0
E Q
3 EQ PANELS
12'-1 1/8"
01.AS.303
01.AS.303
E19
E18
XX.AS.506
XX.AS.506
XX.AS.502
RS32
RS01
01.AS.201
01.AS.202
.A
S .2
XX.AS.502
XX.AS.502
XX.AS.501
E Q
'-0
E Q
6'-7 5/8" 1'-0"
6'-8 1/2" 1'-0"
XX.AS.502
C1-106
DINING
01-01-A38-01
C1-104
PLAY
01-01-A39-01
C1-C01
EXHIB DISPLAY
01-01-A39-02
C1-102
SECURITY DESK
01-01-A40-05
NOTES
1. REFER TO 01.SS.905 FOR OVERALL PROJECT GRID LAYOUT
DIMENSIONS
2. REFER TO 01.SS.904 FOR DETAILED CON GRID LAYOUT
DIMENSIONS - SOUTH
3. REFER TO 01.SS.903 FOR DETAILED CON GRID LAYOUT
DIMENSIONS - NORTH
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R E
S
D A
T
IB
S
IB
N
E N
C
C L C
C B
N
C B
C
C B
S
P S
N
P V
N
P V
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E o n e e ig h th i n c h o n e f o o t
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
Professional Seal
THESE ARE THE MOST CURRENT AS-BUILT CONDITIONS AS OF:
/2
/2
:2
:3
P
M C
U s e rs \h a u n g
\D o c u m e n ts
\A S
-C E
N T
R A
L h a u n g
G
H V
P .r v t
2/28/2024 3:28:35 PM
01.AS.101-D
LEVEL 1 PLAN - AREA E/F
CONCOURSE
08/31/2012
1/8" = 1'-0"1
LEVEL 1 PLAN - AREA E
0' 4' 8' 16' 32'0' 4' 8' 16' 32'
NORTH
FE
DBA C
1/8" = 1'-0"2
LEVEL 1 PLAN - AREA F
0' 4' 8' 16' 32'0' 4' 8' 16' 32'
| Sheets |
| 01.AS.101-D - LEVEL 1 PLAN - AREA E/F |
| 01.AS.103-C - LEVEL 3 PLAN - AREA C/D |
| 01.AS.202 - BUILDING ELEVATIONS |
| 01.AS.401 - STAIR PLANS AND SECTIONS |
File details come from the government source that posted it. Updated .