01.AS.304 Conc elv cont2.pdf

PDF 811 KB Posted

Attached to
Z1DA--554-26-105 Replace Damaged Windows at RMRVAMC (Const) (VA-26-00010269)
Solicitation number
36C25926R0028
Issued by

About this file

This is an architectural drawing document displaying building sections for a concourse area. The document represents the most current as-built conditions as of February 13, 2024, and includes two partial section views at a scale of 3/32 inch equals 1 foot. The drawing depicts a multi-story healthcare facility with multiple levels showing structural systems, mechanical/electrical infrastructure, and spatial organization. The facility appears to include clinic buildings identified as North (Building 08) and Center (Building 09), along with parking facilities (Building 12).

The sections illustrate vertical circulation, floor plates with multiple stories, fenestration patterns, and building envelope systems. The drawing includes a comprehensive building legend indicating various material and system types, and references consultant and architect/engineer professional seals. File naming conventions and project tracking information indicate this is part of a Building Information Modeling (BIM) project file (AS-CENTRAL_haung3GHVP.rvt). The document is intended to serve as reference documentation for existing building conditions and does not contain procurement requirements, response deadlines, pricing information, or other contractual elements typical of federal solicitation documents.

View the file

Other files

File Type Posted
RFI 554-26-105 Replace Damaged Windows 1 14 2026.pdf PDF
36C25926R0028 0003.pdf PDF
Appendix A SOW - 554-26-105 Replace Damaged Windows-rev1.xlsx XLSX spreadsheet
Concourse CON_Tractel _Stamped_Calcs.pdf PDF
Bldg F 11 24 24-022_DAT_As-Builts_Tractel.pdf PDF
Bldg B RES_Tractel_Davit_Arms_As-Builts.pdf PDF
RFI 554-26-105 Replace Damaged Windows 1 14 2026.docx DOCX document
Bldg K IBN_Tractel_As-Builts.pdf PDF
11 24 24-022_PSN_As-Builts_Tractel_Stamped_Calcs.pdf PDF
03.AS.102-B Bldg F.D fp2.pdf PDF
02.AS.201 Bldg B elv.pdf PDF
01.AS.302 Conc elv.pdf PDF
01.AS.101-D Conc partial fp2.pdf PDF
36C25926R0028 0002.docx DOCX document
Site Visit document.docx DOCX document
Bldg K IBN_Stamped_Calcs.pdf PDF
Bldg F 11 24 24-022_DAT_As-Builts_Tractel_Stamped_Calcs.pdf PDF
03.AS.102-A Bldg F.D fp1.pdf PDF
01.AS.303 Conc elv cont1.pdf PDF
Concourse CON_Tractel_As-Builts.pdf PDF
Bldg B RES_Tractel_Davit_Arms_Stamped_Calcs.pdf PDF
554-26-105 Replace Damaged Windows Sign-in sheet.pdf PDF
11 24 24-022_PSN_As Builts Tractel.pdf PDF
03.AS.202 - Bldg F to D Courtyard elv.pdf PDF
01.AS.101-C Conc partial fp1.pdf PDF
Instructions to Offerors.docx DOCX document
36C25926R0028 0001.docx DOCX document
Past Performance Questionnaire_Blank.docx DOCX document
Prime and Sub Contractor Construction Breakdown.xlsx XLSX spreadsheet
Self-Performed and Subcontracted Worksheet.docx DOCX document
Appendix A SOW - 554-26-105 Replace Damaged Windows.xlsx XLSX spreadsheet
RFR - 554-26-105 Replace Damaged Windows at RMRVAMC.pdf PDF
852.219-75 LOS Certification.docx DOCX document
36C25926R0028.docx DOCX document
ICRA- 554-26-105 Replace Damaged Windows.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

09- CLINIC BUILDING (CENTER)

09.AS.301

09.AS.301

08 -CLINIC BUILDING (NORTH)

XX.AS.592

LEVEL 1

100' - 0"

LEVEL 2

120' - 0"

LEVEL 3

140' - 0"

SERVICE LEVEL

80' - 0"

ROOF - CON

171' - 2"

12 - PARKING VISITOR (NORTH)

LEVEL 1

100' - 0"

LEVEL 2

120' - 0"

LEVEL 3

140' - 0"

SERVICE LEVEL

80' - 0"

ROOF - CON

171' - 2"

MTL73

MATERIAL LEGEND

CODE

PC51

MATERIAL

PRECAST CONCRETE

PC61 PRECAST CONCRETE

ST51 STONE

ST52 STONE

MTL61 ALUMINUM - WHITE

MP51A CORRUGATED METAL WALL

PANEL

MP51

CORRUGATED METAL WALL

PANEL - INSULATED BACK-UP

MTL73 ALUMINUM - COPPER METALLIC

EPSS

PAINTED EXPOSED

STRUCTURAL STEEL

GL03 FIRE-RATED GLASS

GL61 LAMINATED GLASS

MTL51 MISCELLANEOUS METALS

STAINLESS STEEL

SST SECURITY MESHMTL52

GL62 BIPV LAMINATED GLASS

GL81 INSULATING LAMINATED

GLASS - CUSTOM FRIT

PC71 PRECAST CONCRETE

MP53 METAL PANEL SOFFIT

MP55 METAL WALL PANEL

MP61

CORRUGATED METAL WALL

PANEL

LVR51 BLAST LOUVER

LVR52 LOUVER

MP52 INSULATED METAL WALL

PANEL

INSULATED METAL WALL

PANEL

MP54

INSUL01

INSUL02

INSUL03

EXTRUDED POLYSTYRENE

HIGH-DENSITY EXTRUDED

POLYSTYRENE

MINERAL FIBER

INSULATION

GL82 MONOLITHIC SPANDREL

GLASS

GL52 INSULATING LAMINATED GLASS

W/ INTEGRAL HORIZ BLINDS

GL51 INSULATING LAMINATED GLASS

LVR53 BLAST LOUVER

MP52A UNINSULATED METAL WALL

PANEL

PC81 PRECAST CONCRETE

FRGW01 FIRE RATED GLAZING WALL

FRGD01 FIRE RATED GLAZING

DOOR

MTL01 MISCELLANEOUS METALS

GL04 LAMINATED GLASS

GL05 LAMINATED GLASS

INSULATING LAMINATED GLASS W/

INTEGRAL HORIZ BLINDS AND

LAMINATED OUTBOARD LITE

GL53

11 12 08 09 13

03040506

Drawing Number

Building Number

Project NumberProject Title

Location

Date Checked Drawn

Drawing Title

Approved: Project Director

Key Plan

CONSULTANTS:

DateRevisions

1 2 3 4 5 6 7 8 9 10 11 12

D

C

B

A

554-501REPLACEMENT MEDICAL CENTER

FACILITY, EASTERN COLORADO

HEALTH CARE SYSTEM

AURORA, COLORADO

N

C O

N

R E

S

D A

T

IB

S

IB

N

E N

C

C L C

C B

N

C B

C

C B

S

P S

N

P V

N

P V

S

13 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14

E th re e t h ir ty

-s e c o n d i n c h o n e f o o t

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT/ENGINEERS:

Professional Seal

THESE ARE THE MOST CURRENT AS-BUILT CONDITIONS AS OF:

/1

/2

:1

:3

P

M C

U s e rs \h a u n g

\D o c u m e n ts

\A S

-C E

N T

R A

L h a u n g

G

H V

P .r v t

2/13/2024 5:16:34 PM

01.AS.304

BUILDING SECTIONS

CONCOURSE

08/31/2012

3/32" = 1'-0"1

PARTIAL SECTION

3/32" = 1'-0"2

PARTIAL SECTION

Sheets
01.AS.302 - BUILDING SECTIONS
01.AS.303 - BUILDING SECTIONS
01.AS.304 - BUILDING SECTIONS
01.AS.305 - BUILDING SECTIONS
01.AS.306 - BUILDING SECTIONS

File details come from the government source that posted it. Updated .