02.AS.201 Bldg B elv.pdf

PDF 1 MB Posted

Attached to
Z1DA--554-26-105 Replace Damaged Windows at RMRVAMC (Const) (VA-26-00010269)
Solicitation number
36C25926R0028
Issued by

About this file

This document is an architectural drawing set showing building elevations and material specifications for a multi-level residential and commercial facility in Aurora, Colorado. The building contains multiple levels including a Service Level (80' - 0"), Level 1 (100' - 0"), Level 2 (116' - 0"), Level 3 (132' - 0"), Penthouse Level (148' - 0"), Roof Level (168' - 0"), and Canopy Level (175' - 7"). The drawing includes north, south, and partial elevation views with detailed cross-sections showing structural elements, MEP systems including standpipe/sprinkler drains with 8" AFG piping, and various utility connections (DTN/ACN/ACS and UPI systems) at different floor levels.

The material legend specifies construction components including precast concrete panels (PC51, PC61, PC71, PC81), stone cladding (ST51, ST52), various glazing systems (laminated glass, insulating glass, fire-rated glass, BIPV glass), corrugated and insulated metal wall panels (MP51-MP55, MP61), aluminum framing (MTL61, MTL73), stainless steel miscellaneous metals (MTL51), blast louvers (LVR51, LVR53), insulation products (INSUL01-03), and fire-rated glazing walls and doors (FRGW01, FRGD01). The elevation drawings indicate the Healthcare System facility is located in Eastern Colorado and show the integration of structural framing, building envelope systems, and mechanical/plumbing infrastructure across all floor levels.

View the file

Other files

File Type Posted
RFI 554-26-105 Replace Damaged Windows 1 14 2026.pdf PDF
36C25926R0028 0003.pdf PDF
RFI 554-26-105 Replace Damaged Windows 1 14 2026.docx DOCX document
Bldg K IBN_Tractel_As-Builts.pdf PDF
11 24 24-022_PSN_As-Builts_Tractel_Stamped_Calcs.pdf PDF
03.AS.102-B Bldg F.D fp2.pdf PDF
01.AS.302 Conc elv.pdf PDF
01.AS.101-D Conc partial fp2.pdf PDF
36C25926R0028 0002.docx DOCX document
Appendix A SOW - 554-26-105 Replace Damaged Windows-rev1.xlsx XLSX spreadsheet
Concourse CON_Tractel _Stamped_Calcs.pdf PDF
Bldg F 11 24 24-022_DAT_As-Builts_Tractel.pdf PDF
Bldg B RES_Tractel_Davit_Arms_As-Builts.pdf PDF
01.AS.304 Conc elv cont2.pdf PDF
Site Visit document.docx DOCX document
Bldg K IBN_Stamped_Calcs.pdf PDF
Bldg F 11 24 24-022_DAT_As-Builts_Tractel_Stamped_Calcs.pdf PDF
03.AS.102-A Bldg F.D fp1.pdf PDF
01.AS.303 Conc elv cont1.pdf PDF
Concourse CON_Tractel_As-Builts.pdf PDF
Bldg B RES_Tractel_Davit_Arms_Stamped_Calcs.pdf PDF
554-26-105 Replace Damaged Windows Sign-in sheet.pdf PDF
11 24 24-022_PSN_As Builts Tractel.pdf PDF
03.AS.202 - Bldg F to D Courtyard elv.pdf PDF
01.AS.101-C Conc partial fp1.pdf PDF
Instructions to Offerors.docx DOCX document
36C25926R0028 0001.docx DOCX document
RFR - 554-26-105 Replace Damaged Windows at RMRVAMC.pdf PDF
Past Performance Questionnaire_Blank.docx DOCX document
Prime and Sub Contractor Construction Breakdown.xlsx XLSX spreadsheet
Self-Performed and Subcontracted Worksheet.docx DOCX document
Appendix A SOW - 554-26-105 Replace Damaged Windows.xlsx XLSX spreadsheet
852.219-75 LOS Certification.docx DOCX document
36C25926R0028.docx DOCX document
ICRA- 554-26-105 Replace Damaged Windows.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SERVICE LEVEL

80' - 0"

LEVEL 2 - RES

116' - 0"

LEVEL 3 - RES

132' - 0"

ROOF LEVEL - RES

168' - 0"

02-AS-310

A

B

C

D

E

F

G

H

J

K

ROOF - RES

168' - 0"

PH LEVEL - RES

148' - 0"

LEVEL 3 - RES

132' - 0"

LEVEL 2 - RES

116' - 0"

LEVEL 1

100' - 0"

SERV LEVEL

80' - 0"

CANOPY LEVEL - RES

175' - 7"

02-AS-310

L

02-AS-311

02-AS-311

XX.AS.540

XX.AS.540

MP52

GL82

GL51

GL51

GL82

GL51

GL82

GL82

GL51

02-AS-201

XX.AS.540

SIM

STANDPIPE/

SPRINKLER

DRAIN

8" A

FG

STANDPIPE/

SPRINKLER

DRAIN

EQEQ

8" A

FG

1'-5"

MP52

5408' - 0"

DTN / ACN / ACS - LEVEL 2

5408' - 0"

DTN / ACN / ACS - LEVEL 2

5368' - 0"

DTN / ACN / ACS - SERVICE

5368' - 0"

DTN / ACN / ACS - SERVICE

5428' - 0"

DTN / ACN / ACS - LEVEL 3

5428' - 0"

DTN / ACN / ACS - LEVEL 3

5448' - 0"

DTN / ACN / ACS - PENTHOUSE

5448' - 0"

DTN / ACN / ACS - PENTHOUSE

5404' - 0"

UPI - LEVEL 2

5404' - 0"

UPI - LEVEL 2

5389' - 0"

UPI - LEVEL 1

5389' - 0"

UPI - LEVEL 1

5433' - 4"

UPI - LEVEL 4

5433' - 4"

UPI - LEVEL 4

80' - 0"

SERVICE LEVEL

80' - 0"

SERVICE LEVEL

98' - 4 1/2"

LEVEL 1 T.O.S

98' - 4 1/2"

LEVEL 1 T.O.S

91' - 6"

SERVICE LEVEL INTERSTITIAL

91' - 6"

SERVICE LEVEL INTERSTITIAL

45' - 3 15/16"

LEVEL 5

45' - 3 15/16"

LEVEL 5

LEVEL 1

100' - 0"

LEVEL 3 - RES

132' - 0"

PH LEVEL - RES

148' - 0"

ROOF LEVEL - RES

168' - 0"

A

B

C

D

E

F

G

H

J

K

ROOF - RES

168' - 0"

PH LEVEL - RES

148' - 0"

LEVEL 3 - RES

132' - 0"

LEVEL 1

100' - 0"

CANOPY LEVEL - RES

175' - 7"

L

EVACUATED

TUBE SOLAR

COLLECTOR

MP51

MP52

5428' - 0"

DTN / ACN / ACS - LEVEL 3

5428' - 0"

DTN / ACN / ACS - LEVEL 3

5448' - 0"

DTN / ACN / ACS - PENTHOUSE

5448' - 0"

DTN / ACN / ACS - PENTHOUSE

5404' - 0"

UPI - LEVEL 2

5404' - 0"

UPI - LEVEL 2

5433' - 4"

UPI - LEVEL 4

5433' - 4"

UPI - LEVEL 4

100' - 0"

LEVEL 1

100' - 0"

LEVEL 1

120' - 0"

LEVEL 2

120' - 0"

LEVEL 2

MATERIAL

LEGEND

CODE

PC51

MATERIAL

PRECAST CONCRETE

PC61 PRECAST CONCRETE

ST51 STONE

ST52 STONE

MTL61 ALUMINUM - WHITE

MP51A CORRUGATED METAL WALL

PANEL

MP51 CORRUGATED METAL WALL

PANEL - INSULATED BACK-UP

MTL73 ALUMINUM - COPPER METALLIC

EPSS PAINTED EXPOSED

STRUCTURAL STEEL

GL03 FIRE-RATED GLASS

GL61 LAMINATED GLASS

MTL51 MISCELLANEOUS METALS

STAINLESS STEEL

SST SECURITY MESHMTL52

GL62 BIPV LAMINATED GLASS

GL81 INSULATING LAMINATED

GLASS - CUSTOM FRIT

PC71 PRECAST CONCRETE

MP53 METAL PANEL SOFFIT

MP55 METAL WALL PANEL

MP61 CORRUGATED METAL WALL

PANEL

LVR51 BLAST LOUVER

LVR52 LOUVER

MP52 INSULATED METAL WALL

PANEL

INSULATED METAL WALL

PANEL

MP54

INSUL01

INSUL02

INSUL03

EXTRUDED POLYSTYRENE

HIGH-DENSITY EXTRUDED

POLYSTYRENE

MINERAL FIBER

INSULATION

GL82 MONOLITHIC SPANDREL

GLASS

GL52 INSULATING LAMINATED GLASS

W/ INTEGRAL HORIZ BLINDS

GL51 INSULATING LAMINATED GLASS

LVR53 BLAST LOUVER

MP52A UNINSULATED METAL WALL

PANEL

PC81 PRECAST CONCRETE

FRGW01 FIRE RATED GLAZING WALL

FRGD01 FIRE RATED GLAZING

DOOR

MTL01 MISCELLANEOUS METALS

GL04 LAMINATED GLASS

GL05 LAMINATED GLASS

INSULATING LAMINATED GLASS W/

INTEGRAL HORIZ BLINDS AND

LAMINATED OUTBOARD LITE

GL53

100' - 0"

LVL 1

100' - 0"

LVL 1

116' - 0"

LVL 2

116' - 0"

LVL 2

168' - 0"

ROOF LVL

168' - 0"

ROOF LVL

148' - 0"

PH LVL

148' - 0"

PH LVL

132' - 0"

LVL 3

132' - 0"

LVL 3

B

C D F G H

J

K

E

100' - 0"

LEVEL 1

100' - 0"

LEVEL 1

A

L

116' - 0"

LEVEL 2 - RES

116' - 0"

LEVEL 2 - RES

132' - 0"

LEVEL 3 - RES

132' - 0"

LEVEL 3 - RES

148' - 0"

PH LEVEL - RES

148' - 0"

PH LEVEL - RES

168' - 0"

ROOF LEVEL - RES

168' - 0"

ROOF LEVEL - RES

175' - 7"

CANOPY LEVEL - RES

175' - 7"

CANOPY LEVEL - RES

XX.AS.540

MP52

GL82

GL51

MP52

XX.AS.541

SIM

LEVEL 1

100' - 0"

MP52MP52

160' - 0"

PH LVL

160' - 0"

PH LVL

LEVEL 1

100' - 0"

A

B

J

K

LEVEL 2 - RES

116' - 0"

LEVEL 3 - RES

132' - 0"

PH LEVEL - RES

148' - 0"

CANOPY LEVEL - RES

175' - 7"

L

GL82

GL51

GL82

GL51

XX.AS.540

SIM

MP52

MP52

LEVEL 1

100' - 0"

MP52MP52

160' - 0"

PH LVL

160' - 0"

PH LVL

160' - 0"

PH LEVEL

160' - 0"

PH LEVEL

148' - 0"

PH LEVEL - RES

148' - 0"

PH LEVEL - RES

168' - 0"

ROOF LEVEL - RES

168' - 0"

ROOF LEVEL - RES

175' - 7"

CANOPY LEVEL - RES

175' - 7"

CANOPY LEVEL - RES

2.9

MP52

MP52

MP52

REMOVABLE

PANEL 8' X 12' LVR53

GL82

MP52

MP52

5428' - 0"

DTN / ACN / ACS - LEVEL 3

5428' - 0"

DTN / ACN / ACS - LEVEL 3

LEVEL 2 - RES

116' - 0"

LEVEL 2 - RES

116' - 0"

LEVEL 1

100' - 0"

8' -4

9' -4

" LEVEL 1

100' - 0"

XX.AS.541

1' -0

8'

-4

9' -4

LEVEL 1

100' - 0"

LEVEL 2 - RES

116' - 0"

LEVEL 3 - RES

132' - 0"

140' - 0"

LEVEL 3

140' - 0"

LEVEL 3

B

C

D

F

G

H

J

K

E

A

B

C

D

E

F

G

H

J

K

PH LEVEL - RES

148' - 0"

GL82

MTL61

GL51

GL82

EPSS

P51

5389' - 0"

UPI - LEVEL 1

5389' - 0"

UPI - LEVEL 1

140' - 0"

LEVEL 3

140' - 0"

LEVEL 3

98' - 4 1/2"

LEVEL 1 T.O.S

98' - 4 1/2"

LEVEL 1 T.O.S

100' - 0"

LEVEL 1

100' - 0"

LEVEL 1

100' - 0"

LEVEL 1

100' - 0"

LEVEL 1

1' -0

7'

-0

GL51

GL82

XX.AS.541

GL51

1' -0

11 12 08 09 13

03040506

Drawing Number

Building Number

Project NumberProject Title

Location

Date Checked Drawn

Drawing Title

Approved: Project Director

Key PlanCONSULTANTS:

DateRevisions

1 2 3 4 5 6 7 8 9 10 11 12

D

C

B

A

554-501REPLACEMENT MEDICAL CENTER

FACILITY, EASTERN COLORADO

HEALTH CARE SYSTEM

AURORA, COLORADO

N

C O

N

R

ES

D

AT

IB

S

IB

N

EN

C

C

LC

C

BN

C

BC

C

BS

PS

N

PV

N

PV

S

13 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14

E th re e th irt y-se co nd in ch o ne fo ot

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT/ENGINEERS:Professional Seal

5/

/2

6:

:2

PM

C :\U se rs

\C

AD

U se r 2 \D oc um en ts

\A S-

C

EN

TR

AL

_c ha rlo tte

.b la ck w oo d.

rv t

02-AS-201

BUILDING ELEVATIONS

RESEARCH BUILDING

08/31/2012

3/32" = 1'-0"1 NORTH ELEVATION

3/32" = 1'-0"2 SOUTH ELEVATION

3/32" = 1'-0"4 SOUTH PARTIAL ELEVATION

3/32" = 1'-0"5 SOUTH PARTIAL ELEVATION

3/32" = 1'-0"6 PARTIAL PH-ELEV

1/4" = 1'-0"8 DOOR E2 ELEV (02 RES)

3/32" = 1'-0"3 SOUTH ELEVATION-BEYOND SOLAR TUBE

1/4" = 1'-0"9 DOOR E3 ELEV (02 RES) (RFI 2221a)

Sheets: 02-AS-201 - BUILDING ELEVATIONS

File details come from the government source that posted it. Updated .