02.AS.201 Bldg B elv.pdf
PDF 1 MB Posted
- Solicitation number
- 36C25926R0028
About this file
This document is an architectural drawing set showing building elevations and material specifications for a multi-level residential and commercial facility in Aurora, Colorado. The building contains multiple levels including a Service Level (80' - 0"), Level 1 (100' - 0"), Level 2 (116' - 0"), Level 3 (132' - 0"), Penthouse Level (148' - 0"), Roof Level (168' - 0"), and Canopy Level (175' - 7"). The drawing includes north, south, and partial elevation views with detailed cross-sections showing structural elements, MEP systems including standpipe/sprinkler drains with 8" AFG piping, and various utility connections (DTN/ACN/ACS and UPI systems) at different floor levels.
The material legend specifies construction components including precast concrete panels (PC51, PC61, PC71, PC81), stone cladding (ST51, ST52), various glazing systems (laminated glass, insulating glass, fire-rated glass, BIPV glass), corrugated and insulated metal wall panels (MP51-MP55, MP61), aluminum framing (MTL61, MTL73), stainless steel miscellaneous metals (MTL51), blast louvers (LVR51, LVR53), insulation products (INSUL01-03), and fire-rated glazing walls and doors (FRGW01, FRGD01). The elevation drawings indicate the Healthcare System facility is located in Eastern Colorado and show the integration of structural framing, building envelope systems, and mechanical/plumbing infrastructure across all floor levels.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SERVICE LEVEL
80' - 0"
LEVEL 2 - RES
116' - 0"
LEVEL 3 - RES
132' - 0"
ROOF LEVEL - RES
168' - 0"
02-AS-310
A
B
C
D
E
F
G
H
J
K
ROOF - RES
168' - 0"
PH LEVEL - RES
148' - 0"
LEVEL 3 - RES
132' - 0"
LEVEL 2 - RES
116' - 0"
LEVEL 1
100' - 0"
SERV LEVEL
80' - 0"
CANOPY LEVEL - RES
175' - 7"
02-AS-310
L
02-AS-311
02-AS-311
XX.AS.540
XX.AS.540
MP52
GL82
GL51
GL51
GL82
GL51
GL82
GL82
GL51
02-AS-201
XX.AS.540
SIM
STANDPIPE/
SPRINKLER
DRAIN
8" A
FG
STANDPIPE/
SPRINKLER
DRAIN
EQEQ
8" A
FG
1'-5"
MP52
5408' - 0"
DTN / ACN / ACS - LEVEL 2
5408' - 0"
DTN / ACN / ACS - LEVEL 2
5368' - 0"
DTN / ACN / ACS - SERVICE
5368' - 0"
DTN / ACN / ACS - SERVICE
5428' - 0"
DTN / ACN / ACS - LEVEL 3
5428' - 0"
DTN / ACN / ACS - LEVEL 3
5448' - 0"
DTN / ACN / ACS - PENTHOUSE
5448' - 0"
DTN / ACN / ACS - PENTHOUSE
5404' - 0"
UPI - LEVEL 2
5404' - 0"
UPI - LEVEL 2
5389' - 0"
UPI - LEVEL 1
5389' - 0"
UPI - LEVEL 1
5433' - 4"
UPI - LEVEL 4
5433' - 4"
UPI - LEVEL 4
80' - 0"
SERVICE LEVEL
80' - 0"
SERVICE LEVEL
98' - 4 1/2"
LEVEL 1 T.O.S
98' - 4 1/2"
LEVEL 1 T.O.S
91' - 6"
SERVICE LEVEL INTERSTITIAL
91' - 6"
SERVICE LEVEL INTERSTITIAL
45' - 3 15/16"
LEVEL 5
45' - 3 15/16"
LEVEL 5
LEVEL 1
100' - 0"
LEVEL 3 - RES
132' - 0"
PH LEVEL - RES
148' - 0"
ROOF LEVEL - RES
168' - 0"
A
B
C
D
E
F
G
H
J
K
ROOF - RES
168' - 0"
PH LEVEL - RES
148' - 0"
LEVEL 3 - RES
132' - 0"
LEVEL 1
100' - 0"
CANOPY LEVEL - RES
175' - 7"
L
EVACUATED
TUBE SOLAR
COLLECTOR
MP51
MP52
5428' - 0"
DTN / ACN / ACS - LEVEL 3
5428' - 0"
DTN / ACN / ACS - LEVEL 3
5448' - 0"
DTN / ACN / ACS - PENTHOUSE
5448' - 0"
DTN / ACN / ACS - PENTHOUSE
5404' - 0"
UPI - LEVEL 2
5404' - 0"
UPI - LEVEL 2
5433' - 4"
UPI - LEVEL 4
5433' - 4"
UPI - LEVEL 4
100' - 0"
LEVEL 1
100' - 0"
LEVEL 1
120' - 0"
LEVEL 2
120' - 0"
LEVEL 2
MATERIAL
LEGEND
CODE
PC51
MATERIAL
PRECAST CONCRETE
PC61 PRECAST CONCRETE
ST51 STONE
ST52 STONE
MTL61 ALUMINUM - WHITE
MP51A CORRUGATED METAL WALL
PANEL
MP51 CORRUGATED METAL WALL
PANEL - INSULATED BACK-UP
MTL73 ALUMINUM - COPPER METALLIC
EPSS PAINTED EXPOSED
STRUCTURAL STEEL
GL03 FIRE-RATED GLASS
GL61 LAMINATED GLASS
MTL51 MISCELLANEOUS METALS
STAINLESS STEEL
SST SECURITY MESHMTL52
GL62 BIPV LAMINATED GLASS
GL81 INSULATING LAMINATED
GLASS - CUSTOM FRIT
PC71 PRECAST CONCRETE
MP53 METAL PANEL SOFFIT
MP55 METAL WALL PANEL
MP61 CORRUGATED METAL WALL
PANEL
LVR51 BLAST LOUVER
LVR52 LOUVER
MP52 INSULATED METAL WALL
PANEL
INSULATED METAL WALL
PANEL
MP54
INSUL01
INSUL02
INSUL03
EXTRUDED POLYSTYRENE
HIGH-DENSITY EXTRUDED
POLYSTYRENE
MINERAL FIBER
INSULATION
GL82 MONOLITHIC SPANDREL
GLASS
GL52 INSULATING LAMINATED GLASS
W/ INTEGRAL HORIZ BLINDS
GL51 INSULATING LAMINATED GLASS
LVR53 BLAST LOUVER
MP52A UNINSULATED METAL WALL
PANEL
PC81 PRECAST CONCRETE
FRGW01 FIRE RATED GLAZING WALL
FRGD01 FIRE RATED GLAZING
DOOR
MTL01 MISCELLANEOUS METALS
GL04 LAMINATED GLASS
GL05 LAMINATED GLASS
INSULATING LAMINATED GLASS W/
INTEGRAL HORIZ BLINDS AND
LAMINATED OUTBOARD LITE
GL53
100' - 0"
LVL 1
100' - 0"
LVL 1
116' - 0"
LVL 2
116' - 0"
LVL 2
168' - 0"
ROOF LVL
168' - 0"
ROOF LVL
148' - 0"
PH LVL
148' - 0"
PH LVL
132' - 0"
LVL 3
132' - 0"
LVL 3
B
C D F G H
J
K
E
100' - 0"
LEVEL 1
100' - 0"
LEVEL 1
A
L
116' - 0"
LEVEL 2 - RES
116' - 0"
LEVEL 2 - RES
132' - 0"
LEVEL 3 - RES
132' - 0"
LEVEL 3 - RES
148' - 0"
PH LEVEL - RES
148' - 0"
PH LEVEL - RES
168' - 0"
ROOF LEVEL - RES
168' - 0"
ROOF LEVEL - RES
175' - 7"
CANOPY LEVEL - RES
175' - 7"
CANOPY LEVEL - RES
XX.AS.540
MP52
GL82
GL51
MP52
XX.AS.541
SIM
LEVEL 1
100' - 0"
MP52MP52
160' - 0"
PH LVL
160' - 0"
PH LVL
LEVEL 1
100' - 0"
A
B
J
K
LEVEL 2 - RES
116' - 0"
LEVEL 3 - RES
132' - 0"
PH LEVEL - RES
148' - 0"
CANOPY LEVEL - RES
175' - 7"
L
GL82
GL51
GL82
GL51
XX.AS.540
SIM
MP52
MP52
LEVEL 1
100' - 0"
MP52MP52
160' - 0"
PH LVL
160' - 0"
PH LVL
160' - 0"
PH LEVEL
160' - 0"
PH LEVEL
148' - 0"
PH LEVEL - RES
148' - 0"
PH LEVEL - RES
168' - 0"
ROOF LEVEL - RES
168' - 0"
ROOF LEVEL - RES
175' - 7"
CANOPY LEVEL - RES
175' - 7"
CANOPY LEVEL - RES
2.9
MP52
MP52
MP52
REMOVABLE
PANEL 8' X 12' LVR53
GL82
MP52
MP52
5428' - 0"
DTN / ACN / ACS - LEVEL 3
5428' - 0"
DTN / ACN / ACS - LEVEL 3
LEVEL 2 - RES
116' - 0"
LEVEL 2 - RES
116' - 0"
LEVEL 1
100' - 0"
8' -4
9' -4
" LEVEL 1
100' - 0"
XX.AS.541
1' -0
8'
-4
9' -4
LEVEL 1
100' - 0"
LEVEL 2 - RES
116' - 0"
LEVEL 3 - RES
132' - 0"
140' - 0"
LEVEL 3
140' - 0"
LEVEL 3
B
C
D
F
G
H
J
K
E
A
B
C
D
E
F
G
H
J
K
PH LEVEL - RES
148' - 0"
GL82
MTL61
GL51
GL82
EPSS
P51
5389' - 0"
UPI - LEVEL 1
5389' - 0"
UPI - LEVEL 1
140' - 0"
LEVEL 3
140' - 0"
LEVEL 3
98' - 4 1/2"
LEVEL 1 T.O.S
98' - 4 1/2"
LEVEL 1 T.O.S
100' - 0"
LEVEL 1
100' - 0"
LEVEL 1
100' - 0"
LEVEL 1
100' - 0"
LEVEL 1
1' -0
7'
-0
GL51
GL82
XX.AS.541
GL51
1' -0
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key PlanCONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R
ES
D
AT
IB
S
IB
N
EN
C
C
LC
C
BN
C
BC
C
BS
PS
N
PV
N
PV
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E th re e th irt y-se co nd in ch o ne fo ot
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:Professional Seal
5/
/2
6:
:2
PM
C :\U se rs
\C
AD
U se r 2 \D oc um en ts
\A S-
C
EN
TR
AL
_c ha rlo tte
.b la ck w oo d.
rv t
02-AS-201
BUILDING ELEVATIONS
RESEARCH BUILDING
08/31/2012
3/32" = 1'-0"1 NORTH ELEVATION
3/32" = 1'-0"2 SOUTH ELEVATION
3/32" = 1'-0"4 SOUTH PARTIAL ELEVATION
3/32" = 1'-0"5 SOUTH PARTIAL ELEVATION
3/32" = 1'-0"6 PARTIAL PH-ELEV
1/4" = 1'-0"8 DOOR E2 ELEV (02 RES)
3/32" = 1'-0"3 SOUTH ELEVATION-BEYOND SOLAR TUBE
1/4" = 1'-0"9 DOOR E3 ELEV (02 RES) (RFI 2221a)
Sheets: 02-AS-201 - BUILDING ELEVATIONS
File details come from the government source that posted it. Updated .