01.AS.101-C Conc partial fp1.pdf
PDF 1 MB Posted
- Solicitation number
- 36C25926R0028
About this file
This is an architectural as-built floor plan document for Level 1 of a healthcare facility in Aurora, Colorado, dated February 13, 2024. The plan depicts two areas (Concourse and Area D) at scales of 1 1/8" = 1'-0" and shows the most current conditions as of the document timestamp.
The Level 1 layout includes multiple functional spaces typical of a healthcare system: concourse areas with seating and retail displays (C1-148 through C1-154), pharmacy operations with prescription filling/assembly and receiving windows (F1-102, F1-105, F1-135, F1-135A), administrative and clinical areas with offices, waiting areas, and reception (E1-200 through E1-216), corridors, elevators, and stairs throughout. Specialized spaces include consultation rooms, HAC (Headache Assessment Center) locations, coffee station, exhibition display, and stretcher/wheelchair storage. The plan indicates typical unit dimensions, corridor widths, and elevation references. The document was created in Revit and prepared by architects/engineers with professional seals, consultants identified, and orientation marked with cardinal directions and a key plan inset showing the building's overall layout.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
UP
DN
CR
MHO
MHO
UP
DN
CE-V06
ELEV
01-01-PGE5
CE-V05
ELEV
01-01-PGE6
C1-149
SEATING
01-01-A16-02
H1-ST1
STAIR
04-01-ST1
HE-P02
ELEV
04-01-PE4
HE-P01
ELEV
04-01-PE3
C
D
B
A
F1-130
CONSULT
03-01-A1-01
F1-132
HAC
03-01-B1-02
03-01-A1-02
CORRIDOR
H1-100
ELEV VEST
04-01-A3-01
G1-ST1
STAIR
08-01-ST1G1-C09
CORRIDOR
08-01-A2-10
G1-200A
TREAT 2
08-01-A2-01 08-01-A3-02
GYM
E
.A
S .2
S E
E
.A
S .1
-B
S E
E
.A
S .1
-C
01.AS.305
01.AS.305
XX.AS.502
XX.AS.501
XX.AS.502
XX.AS.545
XX.AS.SILL8
XX.AS.SILL7
99' - 0"
Z
RS01-A
01.AS.304
01.AS.304
01.AS.302
01.AS.302
01.AS.201
01.AS.202
2 XX.AS.502
SIM
XX.AS.502
2 TYP. UNITS
2'-1"
6'-2 1/8"
2 TYP. UNITS
3'-0"
2'-1 3/4"
XX.AS.503
2A
E8
3'-5 1/4"2'-1 1/8" 2'-7 5/8"
01.AS.306
C1-153
FEMALE TLT
01-01-A15-06
C1-151
HAC
01-01-A16-01
C1-154
COFFEE STATION
01-01-A17-02
C1-152
SEATING
01-01-A17-01
C1-150
SEATING
01-01-A18-03
C1-C01
EXHIB DISPLAY
01-01-A18-02
C1-148
RETAIL DISPLAY
01-01-A18-01
C1-145
SEATING
01-01-A21-01
C1-146
RETAIL DISPLAY
01-01-A22-01
C1-147
SEATING
01-01-A22-02
01-01-ST3
STAIR
CE-V04
ELEV
01-01-PGE7
CE-V03
ELEV
01-01-PGE8
CE-V01
ELEV
01-01-PGE10
CE-V02
ELEV
01-01-PGE9
C
D
B
A
F1-C10
CORRIDOR
03-01-A2-03F1-130
CONSULT
03-01-A1-01
F1-132
HAC
03-01-B1-02
03-01-A1-02
CORRIDOR
F1-135A
PRESCRIP
RECEIVING
WINDOW
03-01-A3-01
F1-102
PRESCRIP
RECEIVING
WINDOW
03-01-A3-01A
F1-105
WAIT
03-01-A4-01
F1-101
WAIT
03-01-A5-01
D1-C19
CORRIDOR
03-01-A6-05
03-01-A8-07
HALL
F1-C07
CORRIDOR
03-01-B3-07
F1-135
PRESCRIP
FILLING/ASSEMBLY
03-01-B2-01
D1-175
OFFICE
03-01-A7-01
E1-C02
CORRIDOR
09-01-A3-06A
E1-205A
OFFICE
09-01-A3-02
E1-216
WAIT
09-01-B2-07
E1-200
RECEPT
09-01-A3-06
E1-201A
OFFICE
09-01-A4-02
E1-300
STRETCHER/W.C.STOR
09-01-A1-01
E1-ST1
STAIR
09-01-ST1
E
.A
S .2
S E
E
.A
S .1
-C
S E
E
.A
S .1
-D
E11
01.AS.305
01.AS.305
01.AS.305
01.AS.305
/8
E
Q P
A N
E L S
'-5
XX.AS.501
99' - 0"
Z
01.AS.201
XX.AS.502
XX.AS.501
XX.AS.502
3'-0 1/2"
2'-1 1/4"
1 TYP. UNIT
3'-5 1/4" 2'-7 5/8"
E10
XX.AS.507
01.AS.306
C1-142
RETAIL DISPLAY
01-01-A23-02
C1-144 MY HEALTHe VET
01-01-A23-01
C1-143 MY HEALTHe VET
01-01-A24-01
C1-147
SEATING
01-01-A22-02
C1-139
SEATING
01-01-A28-01
C1-141
SEATING
01-01-A27-01
C1-C06
PUBLIC
01-01-A30-09
NOTES
1. REFER TO 01.SS.905 FOR OVERALL PROJECT GRID LAYOUT
DIMENSIONS
2. REFER TO 01.SS.904 FOR DETAILED CON GRID LAYOUT
DIMENSIONS - SOUTH
3. REFER TO 01.SS.903 FOR DETAILED CON GRID LAYOUT
DIMENSIONS - NORTH
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R E
S
D A
T
IB
S
IB
N
E N
C
C L C
C B
N
C B
C
C B
S
P S
N
P V
N
P V
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E o n e e ig h th i n c h o n e f o o t
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
Professional Seal
THESE ARE THE MOST CURRENT AS-BUILT CONDITIONS AS OF:
/1
/2
:1
:5
A
M C
U s e rs \h a u n g
\D o c u m e n ts
\A S
-C E
N T
R A
L h a u n g
G
H V
P .r v t
2/13/2024 8:14:54 AM
01.AS.101-C
LEVEL 1 PLAN - AREA C/D
CONCOURSE
08/31/2012
1/8" = 1'-0"1
LEVEL 1 PLAN - AREA C
0' 4' 8' 16' 32'0' 4' 8' 16' 32'
NORTH
FE
DBA C
1/8" = 1'-0"2
LEVEL 1 PLAN - AREA D
0' 4' 8' 16' 32'0' 4' 8' 16' 32'
| Sheets |
| 01.AS.100-A - SERVICE LEVEL PLAN - AREA A |
| 01.AS.100-B - SERVICE LEVEL PLAN - AREA B |
| 01.AS.100-C - SERVICE LEVEL PLAN - AREA C/D |
| 01.AS.100-D - SERVICE LEVEL PLAN - AREA E/F |
| 01.AS.101-A - LEVEL 1 PLAN - AREA A |
| 01.AS.101-B - LEVEL 1 PLAN - AREA B |
| 01.AS.101-C - LEVEL 1 PLAN - AREA C/D |
| 01.AS.101-D - LEVEL 1 PLAN - AREA E/F |
| 01.AS.102-B - LEVEL 2 PLAN - AREA B |
| 01.AS.102-C - LEVEL 2 PLAN - AREA C/D |
| 01.AS.102-D - LEVEL 2 PLAN - AREA E/F |
| 01.AS.103-B - LEVEL 3 PLAN - AREA B |
| 01.AS.103-C - LEVEL 3 PLAN - AREA C/D |
| 01.AS.103-D - LEVEL 3 PLAN - AREA E/F |
| 01.AS.104-B - ROOF LEVEL PLAN - AREA B |
| 01.AS.104-C - ROOF LEVEL PLAN - AREA C/D |
| 01.AS.104-D - ROOF LEVEL PLAN - AREA E/F |
File details come from the government source that posted it. Updated .