Police Department Tile Roof Replacement
Solicitation number
26-03-ITB
Issued by
Indian River County, Florida

About this file

This is a roofing details exhibit prepared by Kimley-Horn for the City of Sebastian, Florida, in support of a tile roof replacement project at the Sebastian Police Department located at 1201 Main Street, Sebastian, Florida 32958. The project scope includes the removal and replacement of the existing clay barrel tile roof with a new clay barrel tile roof, along with waterproofing repairs to identified Roof Top Units (RTUs) on the low-sloped roof sections. The total roof area is 23,234 square feet across 24 roof facets with a predominant pitch of 4/12. The document provides a site plan identifying the location of gutters and downspouts, as well as eight typical roofing details sourced from the 2024 NRCA Roofing Manual and existing construction drawings prepared by REG Incorporated dated October 6, 2003. These details cover standard conditions including eaves with and without gutters, eave/rake transitions, ridge conditions, hip details, sidewall flashing, valleys, clay tile transitions at parapets, and ridge tile transitions to pyramid roof sections.

The document includes two detailed schematics for RTU flashing repair work, with notes establishing that the contractor must perform a test pilot flashing repair at one RTU prior to completing repairs at all identified RTUs to determine efficacy and feasibility. The contractor is required to conduct destructive testing to verify that site conditions align with the proposed flashing details, notify the owner if field conditions prevent completion of RTU flashing repairs, and propose alternative solutions as necessary. Additionally, the contractor must inspect the interior side of each RTU curb for damage, remove and reinstall or reroute conduits as needed, and comply with NRCA Roofing Guidelines when modifying and replacing roof membranes. The document references a Kimley-Horn ClaimsReady Report dated September 11, 2025, with roof measurements and analysis provided by EagleView Technologies.

View the file

Other files

File Type Posted
I_-_26-03-ITB_-_Police_Department_Tile_Roof_Replacement_Stay_of_Procurement_Cancellation.pdf PDF
H_-_26-03-ITB_-_Police_Department_Tile_Roof_Replacement_Stay_of_Procurement.pdf PDF
G_-_26-03-ITB_-_Police_Department_Tile_Roof_Replacement_Intent_to_Award.pdf PDF
G_-_26-03-ITB_-_Police_Department_Tile_Roof_Replacement_Bid_Tabulation_Sheet.pdf PDF
F_-_26-03-ITB_-_Police_Department_Tile_Rook_Replacement_Bid_Opening_Agenda.pdf PDF
E_-_26-03-ITB_-_Police_Department_Tile_Roof_Replacement__Addendum_2.pdf PDF
E_-_26-03-ITB_-_Police_Department_Tile_Roof_Replacement_Addendum_1.pdf PDF
A_-_26-03-ITB_-_EXHIBIT_A_-_Electronic_Price_Sheet_-_Addendum_1.xlsx XLSX spreadsheet
D_-_26-03-ITB_-_Police_Department_Tile_Roof_Replacement_Pre-Bid_Meeting_Sign_In_Sheet.pdf PDF
D_-_26-03-ITB_-_Police_Department_Tile_Roof_Replacement_Pre-Bid_Meeting_Power_Point.pdf PDF
A_-_26-03-ITB_-_EXHIBIT_B_-_Sample_Contract.pdf PDF
A_-_26-03-ITB_-_EXHIBIT_C_-_Section_070150.19_-_Preparation_For_Reroofing.pdf PDF
A_-_26-03-ITB_-_EXHIBIT_E_-_Section_073213_-_Clay_Roof_Tiles.pdf PDF
A_-_26-03-ITB_-_Police_Department_Tile_Roof_Replacement.pdf PDF
A_-_26-03-ITB_-_EXHIBIT_A_-_Electronic_Price_Sheet.xlsx XLSX spreadsheet
A_-_26-03-ITB_-_EXHIBIT_D_-_Section_061600_-_Sheathing.pdf PDF
C_-_26-03-ITB_-_Police_Department_Tile_Roof_Replacement_Pre-Bid_Meeting_Notice.pdf PDF
Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

kimley-horn.com 11601 Kew Gardens Avenue, Suite 200, Palm Beach Gardens, FL 33410 561-463-0665

Legend

Limits of Tile Roof Replacement:

RTUs to be Waterproofed:

Gutter / Downspout (DS):

Job: Sebastian Police Department - Tile Roof Replacement

Location: 1201 Main St, Sebastian, FL 32958

Site Plan

Main St.

F rie nd sh ip L n.

DS 1 DS 2

Eave1 Eave With Gutter2

Source: 2024 NRCA Roofing Manual

Typical Roofing Details

Eave/Rake3 Ridge4

Hip5 Sidewall Flashing With One-Piece Counterflashing

Valley7 Clay Tile Transition at Parapet8

Source: 2024 NRCA Roofing Manual & Construction Drawings Prepared By REG Incorporated and Dated 10/6/2003

Ridge Tile at Transition To Pyramid Roof

Source: Construction Drawings Prepared By REG Incorporated and Dated 10/6/2003

EXISTING RTU FLASHING, TYP.10

PROPOSED RTU FLASHING, TYP.11

RTU AND SKIRT TO

REMAIN IN PLACE

REMOVE TERMINATION BAR, DETERMINE LIMITS

OF SHEET METAL - CONTRACTOR TO DETERMINE

FUNCTIONALITY AND NECESSITY OF SHEET

METAL - INSTALL FLASHING PER DETAIL 11

INSPECT REINFORCED PIB

FLASHING FOR DAMAGE -

REPAIR WITH HOT AIR

WELDED OR ADHEARED

MEMBRANE IF DAMAGED

MODIFY ROOF MEMBRANE AND

CORNER FLASHING AS NECESSARY

TO COMPLETE REPAIR - PLACE

BACK MEMBRANE IN ACCORDANCE

WITH NRCA ROOFING GUIDELINES

NOTES:

1. CONTRACTOR TO PERFORM A TEST PILOT

FLASHING REPAIR AT ONE (1) RTU TO DETERMINE

EFFICACY AND FEASIBILITY OF REPAIR PRIOR TO

COMPLETING DEMO AND REPAIR AT ALL IDENTIFIED

RTUS.

2. DETAIL 11 SHOWS A GENERALIZED SCHEMATIC OF

PROPOSED FLASHING AT AN RTU. DESTRUCTIVE

TESTING MAY SHOW THAT ON SITE CONDITIONS VARY

FROM THOSE SHOWN IN DETAIL 11.

3. CONTRACTOR TO NOTIFY OWNER IF FIELD

CONDITIONS PREVENT COMPLETION OF THE RTU

FLASHING REPAIR AND PROPOSE ALTERNATIVE

SOLUTION TO OWNER.

4. CONTRACTOR TO INSPECT INTERIOR SIDE OF RTU

CURB UNDER EACH RTU FOR DAMAGE AND REPORT

FINDINGS TO OWNER.

REMOVE AND REINSTALL OR

REROUTE CONDUITS AS

NECESSARY TO COMPLETE

REPAIRS, TYP.

LAG BOLT THRU EQUIPMENT CURB

FLANGE TO REMAIN

NEOPRENE STRIP TO REMAIN

RTU SKIRT TO REMAIN

PRESSURE TREATED WOOD

NAILER STRIP TO REMAIN

RTU BASE

EQUIPMENT SUPPORT CURB

AND FRAME TO REMAIN

ADHERE REINFORCED PIB

FLASHING TO ROOF PIB

FIELD MEMBRANE - LAP 4"

CANT STRIP

TO REMAIN

MODIFY ROOF MEMBRANE AS

NECESSARY TO COMPLETE

REPAIR - PLACE BACK MEMBRANE

IN ACCORDANCE WITH NRCA

ROOFING GUIDELINES

ROOF RIGID

INSULATION TO REMAIN

ROOF JOIST

TO REMAIN

ROOF DECK TO REMAIN

Kimley-Horn ClaimsReady™ Report September 11, 2025

© 2008-2025 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152;

8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Measurements provided by www.eagleview.com www.eagleview.com/Guarantee.aspx

1201 Main St, Sebastian, FL 32958

In this 3D model, facets appear as semi-transparent to reveal overhangs.

Report Details Roof Details Report Contents

Report: 67381534 Total Roof Area = 23,234 sq ft Total Roof Facets = 24 Predominant Pitch = 4/12 Number of Stories <=1 Total Ridges/Hips = 380 ft Total Valleys = 108 ft Total Rakes = 39 ft Total Eaves = 1,270 ft Total Penetrations = 37 Total Penetrations Perimeter = 294 ft Total Penetrations Area = 348 sq ft

Images Length Diagram Pitch Diagram Area Diagram Notes Diagram Penetrations Diagram Report Summary

Contact: Jason Goldman Company: Kimley-Horn Address: 1920 Wekiva Way West Palm Beach FL 33411 Phone: 561-593-0423 http://www.eagleview.com/ http://www.eagleview.com/Guarantee.aspx

1201 Main St, Sebastian, FL 32958 September 11, 2025

Report: 67381534 © 2008-2025 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Kimley-Horn Page 1

Images The following aerial images show different angles of this structure for your reference.

Report: 67381534 © 2008-2025 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Kimley-Horn Page 2

North Side

South Side

Report: 67381534 © 2008-2025 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Kimley-Horn Page 3

East Side

West Side

Report: 67381534 © 2008-2025 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Kimley-Horn Page 4

Length Diagram Total Line Lengths:

Ridges = 54 ft Hips = 326 ft

Valleys = 108 ft Rakes = 39 ft Eaves = 1,270 ft

Flashing = 155 ft Step flashing = 88 ft Parapets = 495 ft

Note: This diagram contains segment lengths (rounded to the nearest whole number) over 5 feet. In some cases, segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9).

20 20

39 18 39

SN

W

E

E ag le

V ie w T ec hn ol og ie s, In c.

, A ll

R ig ht s

R es er ve d.

Report: 67381534 © 2008-2025 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Kimley-Horn Page 5

Pitch Diagram Pitch values are shown in inches per foot, and arrows indicate slope direction. The predominant pitch on this roof is 4/12.

Note: This diagram contains labeled pitches for facet areas larger than 20 square feet. In some cases, pitch labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9). Blue shading indicates a pitch of 3/12 and greater. Gray shading indicates flat, 1/12 or 2/12 pitches. If present, a value of "F" indicates a flat facet (no pitch).

4 4

F

SN

W

E

E ag le

V ie w T ec hn ol og ie s, In c.

, A ll

R ig ht s

R es er ve

Report: 67381534 © 2008-2025 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Kimley-Horn Page 6

Area Diagram Total Area = 23,234 sq ft, with 24 facets.

Note: This diagram shows the square feet of each roof facet (rounded to the nearest foot). The total area in square feet, at the top of this page, is based on the non-rounded values of each roof facet (rounded to the nearest square foot after being totaled).

SN

W

E

E ag le

V ie w T ec hn ol og ie s, In c.

, A ll

R ig ht s

R es er ve

Report: 67381534 © 2008-2025 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Kimley-Horn Page 7

Notes Diagram Roof facets are labeled from smallest to largest (A to Z) for easy reference.

T

P S

E

G

U

V

H

F

Q

J

W

L

R

C

X

M

O

K

N

I

DB

A

SN

W

E

E ag le

V ie w T ec hn ol og ie s, In c.

, A ll

R ig ht s

R es er ve

1201 Main St, Sebastian, FL, 32958 September 11, 2025

Report: 67381534 © 2008-2025 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961;

9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Kimley-Horn Page 8

Penetrations Notes Diagram Penetrations are labeled from smallest to largest for easy reference.

Total Penetrations = 37 Total Penetrations Area = 348 sq ft Total Penetrations Perimeter = 294 ft Total Roof Area Less Penetrations = 22,886 sq ft

18 19

21 22

SN

W

E

E ag le

V ie w T ec hn ol og ie s, In c.

, A ll

R ig ht s

R es er ve

Report: 67381534 © 2008-2025 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Kimley-Horn Page 9

Report Summary Below is a measurement summary using the values presented in this report.

All Structures

Areas per Pitch Roof Pitches Area (sq ft) % of Roof

0/12 2/12 4/12

9607.1 2486.2 11139.8 41.3% 10.7% 47.9%

The table above lists each pitch on this roof and the total area and percent (both rounded) of the roof with that pitch.

Penetrations

Area (sq ft) Perimeter (ft)

1-9 10-26 27-28 29 30 31 32 33 34 35

0.2 1 2.2 2.3 4 4.5 24 34.3 41.6 70 2 4 6 6 8 9 20 24.2 25.8 34

Area (sq ft) Perimeter (ft)

36 37

70 73.5 34 35

Any measured penetration smaller than 3x3 feet may need field verification. Accuracy is not guaranteed. The total penetration area is not subtracted from the total roof area.

All Structures Totals

Total Roof Facets = 24 Total Penetrations = 37

Lengths, Areas and Pitches Ridges = 54 ft (3 Ridges) Hips = 326 ft (16 Hips).

Valleys = 108 ft (4 Valleys) Rakes † = 39 ft (2 Rakes) Eaves/Starter ‡ = 1,270 ft (31 Eaves) Drip Edge (Eaves + Rakes) = 1,309 ft (33 Lengths) Parapet Walls = 495 (16 Lengths).

Flashing = 155 ft (5 Lengths) Step flashing = 88 ft (8 Lengths) Total Penetrations Area = 348 sq ft Total Roof Area Less Penetrations = 22,886 sq ft Total Penetrations Perimeter = 294 ft Predominant Pitch = 4/12 Total Area (All Pitches) = 23,234 sq ft

Property Location Longitude = -80.4742917 Latitude = 27.8176023

Notes This was ordered as a commercial property. There were no changes to the structure in the past four years.

Parapet Wall Area Table Wall Height (ft) Vertical Wall Area (sq ft)

1 2 3 4 5 6 7 495 990 1485 1980 2475 2970 3465

This table provides common parapet wall heights to aid you in calculating the total vertical area of these walls. Note that these values assume a 90 degree angle at the base of the wall. Allow for extra materials to cover cant strips and tapered edges.

SN

W

E

E ag le

V ie w T ec hn ol og ie s, In c.

, A ll

R ig ht s

R es er ve d.

† Rakes are defined as roof edges that are sloped (not level).

‡ Eaves are defined as roof edges that are not sloped and level.

Report: 67381534 © 2008-2025 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Kimley-Horn Page 10

Online Maps Online map of property http://maps.google.com/maps?f=g&source=s_q&hl=en&geocode=&q=1201+Main+St,Sebastian,FL,32958 Directions from Kimley-Horn to this property http://maps.google.com/maps?f=d&source=s_d&saddr=1920+Wekiva+Way,West+Palm+Beach,FL,33411&daddr=1201+Main+St,Seb astian,FL,32958

Enclosed is your ClaimsReady report. Please click the link to supplement your report with a walls report that includes areas of facets and cut-outs, line lengths, a notes diagram, and waste table calculations. Request a walls report.

http://maps.google.com/maps?f=g&source=s_q&hl=en&geocode=&q=1201+Main+St,Sebastian,FL,32958 http://maps.google.com/maps?f=d&source=s_d&saddr=1920+Wekiva+Way,West+Palm+Beach,FL,33411&daddr=1201+Main+St,Sebastian,FL,32958 http://maps.google.com/maps?f=d&source=s_d&saddr=1920+Wekiva+Way,West+Palm+Beach,FL,33411&daddr=1201+Main+St,Sebastian,FL,32958 http://maps.google.com/maps?f=d&source=s_d&saddr=1920+Wekiva+Way,West+Palm+Beach,FL,33411&daddr=1201+Main+St,Sebastian,FL,32958 http://maps.google.com/maps?f=d&source=s_d&saddr=1920+Wekiva+Way,West+Palm+Beach,FL,33411&daddr=1201+Main+St,Sebastian,FL,32958 https://apps.eagleview.com/myev/orders/upgrade?upgradeReportId=bTRjY1lTdnFVRVdSNk95bXRJYU5ZUT09

Report: 67381534 © 2008-2025 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436;

8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Important Legal Notice and Disclaimer

Notice and Disclaimer

No Warranty: The Copyrighted Materials are provided to you "as is," and you agree to use it at your own risk.

EagleView Technologies makes no guarantees, representations or warranties of any kind, express or implied, arising by law or otherwise, including but not limited to, content, quality, accuracy, completeness, effectiveness, reliability, fitness for a particular purpose, usefulness, use or results to be obtained from the Copyrighted Materials.

Contractors agree to always conduct a preliminary site survey to verify Roof Report ordered. In the event of an error in a Report, your sole remedy will be a refund of the fees paid by you to obtain this Report.

File details come from the government source that posted it. Updated .