A10-1e BP1_DWG2026-0618_15_ELECTRICAL_IHS-Whiteriver-Hospital_BID-H.pdf
PDF 10 MB Posted
- Attached to
- Whiteriver Hospital Construction
- Solicitation number
- 75H70126R00016
About this file
This document is a set of electrical construction drawings for IHS Whiteriver Hospital located at 200 W Hospital Drive, Whiteriver, Arizona 85941. The project is identified as IHS Project #131445 under IHS Contract #75H70123R00008, with an award date of February 2, 2024. The drawings are prepared by SmithGroup based on a Program of Requirements dated March 26, 2022, a POR Amendment dated February 3, 2025, and schematic drawings approved November 19, 2024.
The electrical design documents include site power plans detailing primary electrical infrastructure such as Navopache Primary Sectionalizing Cabinet (E101), utility transformer (E102), primary circuit extensions (E107), and underground electrical feeders with dedicated routing areas. Additional sheets cover detailed specifications for quadruplex receptacle pedestals with weatherproof outlets, site lighting pole and base details, and comprehensive power distribution plans for multiple building areas including simulations labs, procedure rooms, patient care areas, and equipment rooms. Interior electrical systems specifications address branch circuit wiring (minimum #10 AWG copper), dedicated neutral conductors, ground fault circuit interrupter (GFCI) protection, lighting control systems with occupancy sensors and pillow switch controllers for patient beds, emergency lighting with automatic transfer devices, and centralized lighting control with building management system integration. All work must coordinate with architectural, mechanical, and other trade drawings prior to rough-in and construction.
View the file
Other files
Show 40 more
Latest 50 of 107 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
DN
T TT T T
B,1 N 1,046,408.04E 762,639.83
B,9 N 1,046,427.03E 762,879.08
Y,28 N 1,046,658.90E 763,291.75
U,24 N 1,046,543.26E 763,174.53
A,1 N 1049396.97 E 762103.57
A,5N 1049607.57E 762146.84
C,5N 1049594.09E 762212.47
536870914 5610.87
BASE SET-AT
MISC
MISC
5407.19
SET-AT
5397.92
SET-AT
5371.38
SET-AT
5393.98
SET-AT
5532.80
SET-AT
5407.15
SET-AT
5400.37
SET-AT
5604.95
SET-AT
536870913 5398.06
BASE
WATER
T
T
J
RIM=5444.69INV N=5437.77 8"INV NE=5437.53 8"INV W=5437.59 8"
RIM=5418.45INV NE=5411.08 8"INV SW=5410.94 8"
RIM=5447.39INV W=5440.99 8"INV NW=5440.96 8"
RIM=5443.82INV E=5432.55 8"INV E=5433.22 8"INV SE=5432.24 8"INV SE=5432.36 8"
RIM=5444.04
INV NE=5434.54 8"INV SW=5434.47 8"INV W=5435.80 8"
RIM=5453.01INV NE=5445.69 18"INV SW=5445.56 18"INV NW=5445.87 18"
RIM=5446.62INV SE=5436.72 8"INV SW=5435.59 8"INV NW=5435.66 8"INV NW=5438.81 8"
RIM=5416.80INV NE=5409.66 8"INV SW=5409.50 8"
RIM=5422.88INV NE=5413.05 8"INV NE=5415.69 8"INV SE=5412.30 8"BOTTOM=5412.33
RIM=5433.33INV NE=5424.59 8"INV SW=5423.90 8"INV W=5424.75 8"
EL=5506.14
TD=5504.77
EL=5506.16
TD=5504.88
RIM=5411.07
INV SW=5405.25 8"INV NW=5405.28 8"
INV=5460.12
RIM=5429.25
RIM=5429.38
TN=5425.95
TN=5427.70
N
AV
AJ
O
D R
IV
E
B,1 N 1,046,408.04E 762,639.83
B,9 N 1,046,427.03E 762,879.08
Y,28 N 1,046,658.90E 763,291.75
U,24 N 1,046,543.26E 763,174.53
A,1 N 1049396.97E 762103.57
A,5 N 1049607.57 E 762146.84
C,5 N 1049594.09 E 762212.47
TANK
TANK
TANK
TANK
TANK
TANK
TANKTANK
TANK
KIOWA DRIVE
APACHE CIRCLE
COMMANCHE DRIVE
CHOCTAW DRIVE
KUPER DRIVE
KU
PE
R D
R
IV
E
W 36TH DRIVE
W 36
TH D
RIVE
HO
PI
D
RI
VE
W NASEYOWMA DRIVE
N
PO
W
ER
LI
NE
R O
AD
O
LD
S
AW
M
IL
L
RO
AD
402 OLD SAW
MILL ROAD
402 OLD SAW MILL ROAD
N POTTER STREET
AZ-73
AZ-73
AZ-73
AZ-73
APACHE CIRCLE
AP
AC
H E
C
IR
C
LE
INV=5438.37
INV=5439.14
INV=5505.54
INV=5505.59
INV=5505.65
INV=5504.78
INV=5443.81
INV=5443.24
INV=5504.64
INV=5394.49 60" CMP
INV=5394.46 60" CMP
INV=5394.52 60" CMP
RIM=5459.10
EL=5448.43
EL=5448.66
INV=5420.91
24" CMP
INV=5422.96
24" CMP
TOP=5423.84
24" CMP
TOP=5419.37
24" CMP
INV 18" CMP=5533.93SILTED OVER
INV=5410.92
30X42 PIPE
INV=5412.90
30X42 PIPEINV=5412.50
30X42 PIPE
INV=5398.35 36"
INV=5398.47 36"
INV=5401.46 36"
INV=5401.49 36"
INV=5394.35 60" CMP
INV=5411.07
30X42 PIPE
O
HE
O
HE
O
HE
E
E
E
EE
E E
E
E
E
E
E
E
E
E
E E
E E
E
C O
M M
(F O
C O
M M
COMM(T)
COMM
COMM
COMM
CO
M
M
COMM
COMM
COMM
COMM
C O
M M
(F O
S
6" S(
VC
P)
6"S(VCP)6"S(VCP)
8"W(PVC)8"W(PVC)
8" W
(P
VC
8"
W (P
VC
8" W
(P
VC
8"W(PVC)8"W(PVC)8"W(PVC)8"W(PVC)8"W(PVC)8"W(PVC)
8" W
(P
VC
8"
W (P
VC
W
W
8"W(PVC)
8" W
(P
VC
8" W
(P
VC
8"S
8"S
8"S
8" S
8"S
8" S
8"S 8"S 8"S 8"S
8"S(VCP)
S
8"S(VCP)
8"S(VCP)
8"S(VCP)
8" S
8" S
8" S
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
C O
M M
(F O
C O
M M
(F O
COMM
COMM
COMM
C O
M M
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM(T)
COMM(T)
COMM(T)
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
W
W
8"W
(ABAND)
8"W(ABAND)
8"W(ABAND)8"W(ABAND)
8"W(ABAND)
8"W(ABAND)
8"W(ABAND)
8"W(ABAND)
8"W(ABAND)
8"W(ABAND)8"W(ABAND)
8"W(ABAND)
8" W
(P
VC
8"W(PVC) 8"W(PVC) 8"W(PVC) 8"W(PVC)
W
W
W
8"W (P
VC)
42"X24"SD
"X
"S
D
"S
D
"S
D
SD
"S
D
"S
D
"S
D
18"SD
"S
D
"S
D
"S
D
18"SD
18"SD
"S
D
"S
D
"S
D
"S
D
"S
D
"S
D
"S
D
24"SD
24"SD
36"SD
24"SD
"S
D
"S
D
"S
D
"S
D
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G
G
G
G
G
4"W (PVC)
4" W
(P
VC
4" W
(P
VC
4" W
(P
VC
4" W
(P
VC
8"W
(ABAND)
8"W
(PVC)
8"W
(ABAND)
8"W
(ABAND)
8"W
(ABAND)
8"W
(ABAND)
8"W
(ABAND)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
12"W
(PVC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W (A
C)
6"W
(AC)
6"W
(AC)
6"W
(AC)
6"W
(AC)
12"W
(PVC)
12"W
(PVC)
W
4"W
(PVC)
4"W
(PVC)
4"W
(PVC)
4"W
(PVC)
4"W
(PVC)
8" W
(P
VC
8"
W (P
VC
8"W(PVC)
8"W(PVC)
8"W(PVC)
8"W(PVC)
8"W(PVC)
8"W(PVC)
W
W
W
W
W
6" W
(D
IP
6" W
(D
IP
6"W(DIP)
6"W(DIP)
6" W
(D
IP
6" W
(D
IP
6" W
(D
IP
6"W(DIP)
6" W
(D
IP
6" W
(D
IP
6" W
(D
IP
6" W
(D
IP
6"W(DIP)
3"W(PVC) 3"W(PVC)
3"W(PVC)
6"W(PVC)
6"W(PVC)
6"W(PVC)
W
W
W
W
W
W W
W
W
W
W
8"W(PVC)
8"W(PVC)
8"W(PVC)
8"W(PVC)
8"W(PVC)
8"W(PVC)
8" W
(P
VC
8" W
(P
VC
8" W
(P
VC
8" W
(P
VC
8" W
(P
VC
8" W
(P
VC
4"
W (P
VC
4" W
(P
VC
W
W
2" W
2" W
2" W
6"W(PVC)
6"W (P
VC)
6" W
(P
VC
6" W
(P
VC
8" W
(P
VC
8"
W (P
VC
8"W(PVC)
8"W(PVC)
8"W(PVC)
8"W(PVC)
8" W
(P
VC
8"
W (P
VC
6"W
(PVC)
6"W(PVC)
6"W(PVC)
6"W
(PVC)
3"W(PVC)
3"W(PVC)
3"W(PVC)
3"W(PVC)
6" W
(P
VC
6" W
(P
VC
6"W(PVC)
6" W
(P
VC
3"W(PVC)
3"W(PVC)
"W
(P
VC
"W
(P
VC
"W
(P
VC
"W
(P
VC
"W
(P
VC
"W
(P
VC
"W
(P
VC
"W
(P
VC
"W
(P
VC
"W
(P
VC
"W
(P
VC
"W
(P
VC
"W
(P
VC
OHE
OHE
OHE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
O H
E
OHE
OHE
OHE
OHE
O
HE
O
HE
O
HE
O H
E
O H
E O
H E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
EO
H
E O
H
EO
H E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
O H
E
OHE
OHE
O H
E
O
HE
O
HE
O
HE
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
COMM(FO)
C O
M M
(F O
C
O M
M (F
O
C O
M M
(F O
CO
M M
(F O)
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
C O
M M
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
CO
M
M
C O
M M
COMM
COMM
CO
M
M
CO
M
M
CO
M
M
C O
M M
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COM
M
CO
M
M
CO
M
M
CO
M
M
CO
MM
COMM
COMMCO
M
M
CO
M
M
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
C O
M M
COMM
COMM
COMM
CO
M
M
COMM
COMM
COMM
COMM
COMM
CO
MM
CO
MM
CO
MM
COMM
COMM
COMM
COMM
COMM COMM
C O
M M
C O
M M
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8" S
8" S
8" S
8" S
8" S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S(VCP)
8"S(VCP)
8"S(VCP)
8"S(VCP)
8"S(VCP)
8"S(VCP)
8"S(VCP)
8"S(VCP)
8"S(VCP)
8" S(V
CP)
8" S(V
CP)
8" S(V
CP)
8" S(V
CP)
8" S(V
CP)
8" S(V
CP)
8" S(V
CP)
8"S
8"S
8"S
8"S
S
S
S
S
S
8"S
8" S
S
S
8" S
8" S
8" S
8"S
8" S
8" S
8" S
8" S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8"S
8" S
8" S
8" S
8" S
8" S
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC) 8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8" S(
PV
C)
8" S(
PV
C) 8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8" S(
PV
C)
8" S(
PV
C
8" S(
PV
C)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8" S(
PV
C)
8" S(
PV
C)
8" S(
PV
C)
8"S(PVC)
8"S(PVC)
8"S(PVC)
8"S(PVC)
S
S
S
8" S
8" S
6"W (A
C)
4"W
(PVC)
2"W (P
VC)
4"W
(PVC
6"W (A
C)
4" W
(P
VC
60"SD
AB
(N) INV 5438.59 6"VCP(W) INV 5438.42 8"VCP
AB
INV 5435.33 6"VCP (N)INV 5435.16 8"VCP (E/W)
AB
INV 5443.00 6"VCP
AB
INV 5451.60 4"VCP
AB 354LF@0.92%
AB 430LF@0.40%
DESIGN
RIM = 5450.07INV IN (W) = 5447.22INV IN (W) = 5435.69INV IN (N) = 5435.71INV IN (NE) = 5435.75INV OUT (S) = 5435.49
8"W (P
VC)
8" W
(P
VC
6"
W (A
C)
3"W (PVC)
3"W (PVC)
36"SD
"X30
"SD
12"SD
"S
D
36"SD
24"SD
42"SD
42"SD
TS
TS
E
PI
2+
.0
PI 27+11.31
PC 5+26.46
PC 8+21.87
PC 9+43.64
PC 12+68.36
PC
3+
.1
PC 15+10.87
PC 17+38.55 PC
5+
.8
PC 31+73.54
PT 5+54.77
PT 8+61.16
PT 9+67.51
PT
3+
.3
PT 14+09.46
PT 15+22.32
PT
7+
.9
PT 26+41.24
PT 31+95.52
PT 336+62.61
PI 356+15
PC 10+66.38
PT 1
1+
.98
PC 16
+4
1.1
PT 17+09.71
PC 20+38.37
PT 21+15
PC 24+11.97
PT 24+70.04
L=11.46, R=63.00 Δ=010°25'08"
L=
.4 0, R= 43.00
Δ=
8 °29'41"
L= 82.43 , R= 83.00
Δ= 056 °53'58"
L=
21.98 , R= 63.50
Δ= 019°50'04"
L=
39.28 , R= 58.00
Δ= 038°48'28"
L=
.8 7, R= 2 7
.0
Δ=
°3
9'
L=
.9 9, R= 40.00
Δ=
4 °31 '41
L= 41.35, R= 25.00 Δ= 094 °46'13
1+00
2+00
3+00
4+00
6+
7+
8+
9+00
+0
+0
13+00 14 +0
+0
+0
18+00 19+00 21+00 22+00 23+00
24+00
26+00
27+00
28+00
29+00
31+00
32+00
33+00
7+
8+
9+
0+
1+
2+
3+
4+
336+00
337+00
338+00
339+00
341+00
342+00
343+00
344+00
346+00
347+00
348+00
349+00
351+00
352+00
353+00
354+00
356+00
357+00
358+00
359+00
11+00
12+00
13+00
14+00
16+00
+0
+0
+0
+0
+0
+0
+0
0+00
5+00
+0
+0
20+00
25+00
30+00
33+47.24
6+
0+
5+
340+00
345+00
350+00
355+00
360+00
360+86.75
+0
15+00
+0
+0
+5
8"W
8"W
8"S 8"S
8" S
1-1/2"PP
1- 1/
2"
PP
6"W
6"W
8" F
12"W
"W
"W
12"W
12"W
12"W
12"W
12"W
8"W
12"W 8"W
12"W 8"W
12"W
8"W
12"W
8"W
12"W
8"W
12"W
8"W
12"W
8"W
12"W
8"W
"W
"W
"W
"W
12"W
12"W
12"W
"W
"W
12"W
12"W
"W
"W
W
12"W
12"W
2" W
12"W
12"W
12"W 12"W
6" W
1.
5"
W
12"W
6"F 2"W
8"W
8"SD
"S
D
36"SD
"S
D
"S
D
36"SD
24"SD
36"SD
36"SD
36"SD
36"SD
6"SD
8"SD
"S
D
"S
D
48"SD
"S
D
30"SD
24"SD
"S
D
24"SD
24"SD
18"SD
"S
D
"S
D
"S
D
8"
SD
12"
18"SD
18"SD
18"SD
24"SD
24"SD
24"SD
12"SD12"SD
8"
SD
24"SD
24"SD
24"SD
"S
D
"S
D
"S
D
24"SD
24"SD
8"SD
8"SD
"S
D
6"SD
18"SD
"S
D
8"
SD
8"SD
4"
SD
8"SD
6"SD
3"
SD
8"
SD
10"SD
6"SD
6"SD
18"
24"SD
6"
SD
8"SD
12"SD
SD SD
SD
SD
S S
S
S
SD
SD
SD
SD
SD
SD
SD
ARV
ARV
ARV
ARV
ARV
SD
SD
SD
SD
SD
390'
Storage
140'
Gap
250'
Storage
140'
Gap
300'
Storage
137.19'
Gap
CLEAR ZONE
CLEAR ZONE
CLEAR ZONE
CLEAR ZONE
CLEAR ZONE
360'
Thru Lane Begins
10.0000
20.0000
88.0000
10.0000
20.0000
88.0000
20.0000
88.0000
7' x1
5' x8
0C F
6"S(FM)
6"S(FM)
8" W
(R
CL
M
8" W
(R
CL
M
8"W(RCLM)
8" W
(R
CL
M
8" W
(R C
LM
8"W(RCLM)
8"W(RCLM)
6" W
(R C
LM
4"W
4"W(RCLM)
8" W
(R C
LM
8"W(RCLM)
8" W
(R
CL
M
8" W
(R
CL
M
2" W
(R C
LM
8" W
(R
CL
M
8" W
(R
CL
M
8"W(RCLM)
12"W
"W
6"
8" W
"W
8" W
"W
8" W
12"W
"W
"W
"W
"W
"W
"W
8" W
"W
"W
8" W
"W
"W
8" W
8"F
1.5"W
8"W
8"W
6"
24"SD
24"SD
72"SD
"S
D
12"SD
12"SD
"S
D
"S
D
"S
D
"S
D
6"S(FM)
6"S(FM
6"S(FM)
6" S(
FM
6" S(
FM
6" S(
FM
6" S(
FM
6"S(FM)
6"S(FM)
6" S(
FM
6" S(
FM
6" S(
FM
6" S(
FM
6" S(
FM
6" S(
FM
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SD
536870914 5610.87
BASE SET-AT
FND-BCF BLMN 1050513.84E 761921.77
5735.66
FND-BCF BLMN 1047873.63E 761926.11
5530.75
FND-BCF GLON 1042593.16E 761937.40
5365.84
FND-BCF BLMN 1047880.88E 764536.91
5538.29
FND-ACF ADOTHDN 1045501.72E 762424.53
5411.24
FND-ACF ADOTHDN 1044866.75E 762085.01
5411.98
FND-RB 19817N 1048444.23E 761966.82
5564.58
FND-RB
N 1046927.40E 763978.90 5450.02
FND-RB 19817N 1045743.32E 762664.21
5411.14
FND-RB 19817N 1046592.64E 761976.48
5449.76
FND-RB 19817N 1046615.50E 761993.64
5450.04
FND-RB 19817N 1047192.16E 762263.33
5484.28
FND-RB 19817N 1047452.61E 761667.59
5497.89
FND-RB
N 1047201.48E 762267.72 5484.10
FND-ACF ADOTHDN 1045371.30E 762541.28
5398.62
FND-ACF ADOTHDN 1045551.19E 762704.33
5401.90
FND-ACF ADOTHDN 1045532.72E 762720.93
5398.80
FND-ACF ADOTHDN 1045352.80E 762558.22
5399.12
FND-BCF
N 1045192.90E 761836.06 5431.76
47SET-RB CK-67N 1053448.93E 764774.835639.85 48FND-BCFN 1054935.00E 767249.185557.18
BM FND-BCF G43N 1045372.40E 762569.85
5398.06
67SET-RB CK-47N 1053448.94E 764774.845639.79
RIM=5417.73
IN
V=5407.17
INV=5407.18
RIM=5410.38
IN
V=5400.01
INV=5400.48
RIM=5407.57
INV=5399.69
IN
V=5399.97
RIM=5405.85
INV=5398.84
IN
V=5398.92
RIM=5398.75
INV=5392.79
IN
V=5392.82
100SET-RB CK-67 CK-47 DAY2
N 1053448.91E 764774.825639.83
INV=5475.69
INV=5476.45
MISC
INV=5452.25
INV=5452.14
INV=5451.26
INV=5451.08
MP-METALPOST
MISC
MP-METALPOST
FF=5615.91 FF=5615.94RIM=5615.89RIM=5615.86MP-LIFTRIM=5615.83RIM=5615.93TN=5613.74TN=5613.69RIM=5615.70MP-UNKOWNMETAL
TN=5611.35RIM=5615.40TN=5613.40 RIM=5615.62TN=5614.522000SET-RB CK-47-67 DAY2
N 1053448.91E 764774.825639.86
INV=5397.78
INV=5398.00
INV=5397.89
INV=5397.87
INV=5405.31
INV=5407.24
INV=5475.45
MP-TANKMP-TANKMP-TANKMP-TANK MP-TANK MP-TANKMP-TANKMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATER MP-TOPOFWATER MP-TOPOFWATER MP-TOPOFWATER MP-TOPOFWATER MP-TOPOFWATER MP-TOPOFWATER MP-TOPOFWATER MP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATERMP-TOPOFWATER FF=5615.93 FF=5615.93FF=5615.86FF=5616.14 MP-ROCKPILEMP-ROCKPILEMP-ROCKPILEMP-ROCKPILE
5407.19
SET-AT
5397.92
SET-AT
5371.38
SET-AT
5393.98
SET-AT
5532.80
SET-AT
5407.15
SET-AT
5400.37
SET-AT
5604.95
SET-AT
536870913 5398.06
BASE
INV=5438.40
INV=5519.08
INV=5520.92
INV=5505.62
INV=5482.23INV=5482.20
INV=5482.00
INV=5481.85
INV=5481.72
INV=5481.84
INV=5475.86
INV=5476.84
INV=5460.29
INV=5453.38
INV=5443.83
INV=5443.08
INV=5453.63
INV=5454.68
EL=5462.36
INV=5460.34
INV=5448.73
INV=5450.62
INV=5447.91
INV=5445.74
INV=5442.53
WATER
INV=5432.04
INV=5431.84
INV=5420.92
INV=5431.91
RIM=5429.24
TN=5426.24
INV=5433.94
EL=5425.26
MP-MANGLEDCORRIGATEDPIPE
INV=5424.06
INV=5427.99
INV=5427.00
INV=5426.34
INV=5476.40
INV=5412.84
INV=5435.91
INV=5406.93
INV=5406.88
INV=5406.36
INV=5406.47
INV=5407.77
INV=5408.06
RIM=5415.75
RIM=5415.50
RIM=5416.75
RIM=5418.10
MP-NOTFOUND
MP-NOTFOUND
T
TS
A.
B.
C.
COORDINATE WITH LOCAL UTILITY FOR ALL SITE SERVICE
REQUIREMENTS.
CONTACT LOCAL UTILITY TO IDENTIFY ALL EXISTING
UNDERGROUND UTILITIES.
COORDINATE ALL UNDERGROUND ROUTINGS AND DEPTHS
WITH CIVIL PRIOR TO BEGINNING WORK.
GENERAL SHEET NOTES
EXISTING BUILDING
TO REMAIN
EXISTING BUILDING
TO REMAIN
GT
GTGT
GT
GT
GT
GT
GT
E105
TYP
E104
E106
TYP
E102
TYP
E107E108
E101
E112
E112
E109
E111
TYP
OF 2
EXISTING HOSPITAL E101
E102
E151
E107
E107
E101
E128
E128
E129
EXISTING CUP
E130
E129
EXISTING SUPPORT
BUILDING
E123
E134
E132
HT-2
E135
E1.5.P1
E133
PH-PL
E1.1.P1
E147
ELSH
ELSP
ELSH - 38,40,42
TELSP
WR
ELSP- 1
S16
ELSH- 7
E143E144
E145
E146
SHEET NUMBER
PROJECT NUMBER
SEALS AND SIGNATURES
ISSUED FOR DATE
Pl ot
Da te:
IHS Whiteriver Hospital 200 W Hospital Drive Whiteriver, Arizona, 85941
IHS Project #: 131445 IHS Contract #: 75H70123R00008 IHS Award Date: 02/02/2024
455 NORTH THIRD STREET
SUITE 250
PHOENIX, AZ 85004
602.265.2200 smithgroup.com
Drawn By: Checked By:
BASED ON PROGRAM OF REQUIREMENTS DATED [ 03/26/22],
POR AMENDMENT DATED [ 02/03/25], AND ON SCHEMATIC
DRAWINGS APPROVED [11/19/24].
6/1 8/2
6 3
:48 :06
P M
ELECTRICAL SITE POWER
PLAN PHASE 1
E1.1.P1CD
W hit tin gto n
14904.000 Whittington Baca
SHEET KEYNOTES
0 80' 160' 240'
GRAPHIC SCALE: 1" = 80' - 0"
PROJECT NORTH
E101 NEW NAVOPACHE PRIMARY SECTIONALIZING CABINET.
E102 NEW NAVOPACHE UTILITY TRANSFORMER.
E104 3/0 STRANDED BARE COPPER GROUND RING. REFER TO
GROUNDING DETAIL FOR ADDITIONAL INFORMATION.
E105 GROUND TEST WELL. COORDINATE EXACT LOCATION WITH
GENERAL AND LANDSCAPE CONTRACTOR PRIOR TO
COMMENCING WORK.
E106 HATCHED AREA INDICATES SPACE DEDICATED FOR ROUTING
OF UNDERGROUND ELECTRICAL FEEDERS. AREA SHALL BE
KEPT CLEAR OF OTHER SERVING UTILITIES AND
OBSTRUCTIONS.
E107 NEW NAVOPACHE PRIMARY CIRCUIT EXTENSION,
PREFERRED SOURCE.
E108 NEW NAVOPACHE PRIMARY CIRCUIT EXTENSION,
ALTERNATE SOURCE.
E109 RESERVED 15' X 15' SPACE FOR FUTURE UTILITY AND
DISTRIBUTION EQUIPMENT TO SERVE FUTURE 3RD PARTY
EVSE.
E111 PROVIDE (2) 1-1/2" CONDUITS STUBBED TO LOCATIONS
SHOWN FOR FUTURE 3RD PARTY EVSE.
E112 NEW NAVOPACHE PRIMARY CIRCUIT EXTENSION,
PREFERRED SOURCE, EXTENDED FROM EXISTING
OVERHEAD UTILITY INFRASTRUCTURE, TRANSITIONING TO
UNDERGROUND.
E123 EXISTING BUILDING TO REMAIN THROUGHOUT
CONSTRUCTION.
E128 EXISTING GENERATOR TO BE SALVAGED. CONTACT
MANUFACTURER AND REQUEST LONG TERM STORAGE
PREPARATION PROCEDURE. GENERATOR SHALL BE
PREPARED FOR LONG TERM STORAGE PER EQUIPMENT
MANUFACTURERS RECOMMENDATIONS. DOCUMENTED
EXECUTION OF PREPARATION PROCEDURE SHALL BE
PROVIDED TO OWNER FOR VERIFICATION. GENERATOR
SHALL BE PACKAGED FOR STORAGE AND TRANSPORTED TO
WHITE MOUNTAIN TRIBAL AUTHORITY, 1306 S INDUSTRIAL
RD, WHITERIVER, AZ 85941, AS PART OF THIS PROJECT
SCOPE. ALL ASSOCIATED LINE/LOW VOLTAGE CONDUCTORS
AND RACEWAY SHALL BE DEMOLISHED. COORDINATE TIMING
OF GENERATOR SALVAGING WITH INDIAN HEALTH SERVICES
PRIOR TO COMMENCING WORK.
E129 EXISTING BUILDING TO BE DEMOLISHED AT CONCLUSION OF
PHASE 1 / START OF PHASE 2. ELECTRICAL CONTRACTOR
SHALL COORDINATE REQUIRED ELECTRICAL DEMOLITION
SCOPE WITH GENERAL CONTRACTOR AND PROVIDE
SERVICES ACCORDINGLY. ELECTRICAL CONTRACTOR SHALL
CONTACT NAVOPACHE TO COORDINATE DEMOLITION SCOPE
ASSOCIATED WITH UTILITY.
E130 EXISTING BUILDING TO BE DEMOLISHED AT CONCLUSION OF
PHASE 1 / START OF PHASE 2. ELECTRICAL CONTRACTOR
SHALL COORDINATE REQUIRED ELECTRICAL DEMOLITION
SCOPE WITH GENERAL CONTRACTOR AND PROVIDE
SERVICES ACCORDINGLY.
E132 EXTEND PRIMARY UTILITY FEED FROM EXISTING
NAVOPACHE POWER POLE TO NEW TEMPORARY,
NAVOPACHE UTILITY TRANSFORMER.
E133 PROVIDE 100A RATED EXTERIOR RATED PAD MOUNTED
208/120V SINGLE PHASE INTEGRAL COMMERCIAL METER
PEDESTAL LOAD CENTER WITH PHOTOCELL CIRCUIT
CONTROL TO SERVE PARKING LOT LIGHTING. 8 BRANCH
CIRCUITS MINIMUM. PROVIDE 18 INCH CONCRETE PIER
FOUNDATION EXTENDING BELOW FROST LINE. EQUIPMENT
BY MILBANK CP3BA1121122GPSLME01 OR APPROVED EQUAL.
SHALL BE NAVOPACHE COMPLIANT.
E134 UPON COMPLETION OF PUMP HOUSE CONSTRUCTION, THE
TEMPORARY NAVOPACHE PRIMARY UTILITY FEED FROM
EXISTING TO POLE TO PARKING LOT LIGHTING SERVICE
ENTRANCE EQUIPMENT AND ASSOCIATED NAVOPACHE
UTILITY TRANSFORMER SHALL BE DEMOLISHED. PARKING
LOT LIGHTING SERVICE ENTRANCE EQUIPMENT SHALL BE
SERVED FROM PUMP HOUSE ELECTRICAL DISTRIBUTION
EQUIPMENT. REFER TO PUMP HOUSE ELECTRICAL PLANS.
E135 EXISTING PRIMARY UTILITY CIRCUIT SERVING EXISTING
HOSPITAL TO REMAIN THROUGH COMPLETION OF NEW
REPLACEMENT HOSPITAL CONSTRUCTION, PHASE 1.
E143 PROVIDE FIXTURE MOUNTED TOP OF FIXTURE 6 INCHES
BELOW TOP OF WALL ON RECESSED BOX.
E144 PROVIDE TIMER DEVICE WITH 1,2,4,6 HR TIME INTERVALS
WITH 5 MINUTE WARNING FLASH IN WEATHERPROOF WHILE
IN USE BOX FOR CONTROL OF LIFT STATION ENCLOSURE
FIXTURE.
E145 PROVIDE 480V/200A/3P/NEMA 3R STAINLESS STEEL /FUSED
DISCONNECT TO 72HP LIFT STATION MAINS POWER.
TERMINATE LINE CONNECTIONS. LOAD SIDE CONNECTION
PROVIDED BY SYSTEM PROVIDER. PROVIDE FUSING PER
SYSTEM PROVIDER. COORDINATE FINAL REQUIREMENTS
WITH SYSTEM PROVIDER.
E146 PROVIDE EQUIPMENT SURFACE MOUNTED TO CONCRETE
SCREEN WALL. TOP OF EQUIPMENT NO HIGHER THAN 6
INCHES FROM TOP OF WALL. TYPICAL.
E147 PROPOSED ROUTING FOR LIFT STATION UNDERGROUND
POWER FEEDER TO SOURCE PANEL IN MAIN BUILDING. FIELD
COORDINATE FINAL LOCATION WITH CIVIL. REFER TO SES-E
SINGLE LINE FOR ADDITIONAL INFORMATION.
E151 NEW NAVOPACHE PRIMARY SECTIONALIZING CABINET TO
SERVE AS ALTERNATE UTILITY CIRCUIT PATH.SCALE: 1" = 80'-0"1 ELECTRICAL SITE POWER PLAN PHASE 1
SCALE: 1" = 10'-0"2 ENLARGED LIFT STATION ELECTRICAL PLAN
FINAL CONSTRUCTION DOCUMENTS 23JAN26
BID ADDENDUM-H 18JUN26
H
06-18-26
6-30-28
24"
MIN
HEIGHT
PER
LIGHTING
SCHEDULE
#6 INSULATED GROUNDWIRE
BOND TO FIXTURE, TYPICAL.
BOND TO POLE, TYPICAL
#4 BARE COPPER GROUND WIRE;
BOND TO FIXTURE, TYPICAL.
FORM BASE USING SEAMLESS
LINER (NO SPIRAL LINES OR
CONCRETE FLASHING ALLOWED)
PROVIDE 1.5" BEVELED CORNERS.
SACK AND PATCH SURFACE TO
UNIFORM ARCHITECTURAL FINISH.
LONG RADIUS, PVC COATED,
RIGID STEEL CONDUIT ELBOWS
TYPICAL.
BOND CONDUIT GROUND
BUSHINGS & CIRCUIT GROUND
CONDUCTOR TO POLE & FIXTURE
POLE
CONCRETE POURED AGAINST WELL
COMPACTED EARTH. POLE MANUFACTURER
SHALL PROVIDE STRUCTURAL CALCULATIONS
FOR POLE BASE. CALCULATIONS SHALL BE
SEALED & SIGNED BY A STRUCTURAL ENGINEER
REGISTERED IN THE STATE OF ARIZONA &
INCLUDED IN LIGHTING SUBMITTAL PACKAGE.
PER
STRUCTURAL
ENGINEER
PE
R
ST
RU
CT
UR
AL
EN
GI
NE
ER
HAND HOLE WITH
TAMPER PROOF SCREWS
COMPACTED BACKFILL
PROVIDE CAST PULL BOX AND
WEATHER PROOF JUNCTION
BOXES FOR LINE AND LOW
VOLTAGE CIRCUITING AS
REQUIRED. REFER TO ELECTRICAL
SITE PLAN FOR ADDITIONAL
INFORMATION.
LIGHT FIXTURE, TWIN HEAD IF
APPLICABLE
REFER TO LIGHT FIXTURE
SCHEDULE
& ELECTRICAL SITE PLAN FOR
ADDITIONAL INFORMATION
LOW VOLTAGE SECURITY
CAMERA. PROVIDE ADDITIONAL
HANDHOLES IN POLE. REFER TO
'T' SERIES PLANS FOR SPECIFIC
POLE LOCATIONS AND
ADDITIONAL INFORMATION.
DETAIL NOTES:
1. PROVIDE UNDERGROUND PULL BOXES AS
REQUIRED. COORDINATE LOCATION WITH CIVIL
ENGINEER AND ARCHITECT.
40"
24"
MIN
#6 INSULATED GROUNDWIRE
BOND TO FIXTURE, TYPICAL.
BOND TO POLE, TYPICAL
#4 BARE COPPER GROUND WIRE;
BOND TO FIXTURE, TYPICAL.
FORM BASE USING SEAMLESS
LINER (NO SPIRAL LINES OR
CONCRETE FLASHING ALLOWED)
PROVIDE 1.5" BEVELED CORNERS.
SACK AND PATCH SURFACE TO
UNIFORM ARCHITECTURAL FINISH.
LONG RADIUS, PVC COATED,
RIGID STEEL CONDUIT ELBOWS
TYPICAL.
BOND CONDUIT GROUND
BUSHINGS & CIRCUIT GROUND
CONDUCTOR TO POLE & FIXTURE
POLE
CONCRETE POURED AGAINST WELL
COMPACTED EARTH. POLE MANUFACTURER
SHALL PROVIDE STRUCTURAL CALCULATIONS
FOR POLE BASE. CALCULATIONS SHALL BE
SEALED & SIGNED BY A STRUCTURAL ENGINEER
REGISTERED IN THE STATE OF ARIZONA &
INCLUDED IN LIGHTING SUBMITTAL PACKAGE.
PER
STRUCTURAL
ENGINEER
PE
R
ST
RU
CT
UR
AL
EN
GI
NE
ER
HAND HOLE WITH
TAMPER PROOF SCREWS
COMPACTED BACKFILL
LIGHT FIXTURE, TWIN HEAD IF
APPLICABLE
REFER TO LIGHT FIXTURE
SCHEDULE
& ELECTRICAL SITE PLAN FOR
ADDITIONAL INFORMATION
LOW VOLTAGE SECURITY
CAMERA. PROVIDE ADDITIONAL
HANDHOLES IN POLE. REFER TO
'T' SERIES PLANS FOR SPECIFIC
POLE LOCATIONS AND
ADDITIONAL INFORMATION.
6"
PROVIDE CAST PULL BOX AND
WEATHER PROOF JUNCTION
BOXES FOR LINE AND LOW
VOLTAGE CIRCUITING AS
REQUIRED. REFER TO ELECTRICAL
SITE PLAN FOR ADDITIONAL
INFORMATION.
HEIGHT
PER
LIGHTING
SCHEDULE
2"
12"
4"
2"
12" 12"
1'- 2"
"1.5
2'- 0"
EQ. EQ.
KEYED NOTES
RECTANGULAR STRAIGHT STEEL TUBE 3"x6"x24" LONG, 3/16" THICK.
PRIME AND PAINT, COLOR TO BE DETERMINED BY OWNER.
1/8" THICK STEEL TOP. PROVIDE CONTINUOUS WELD ALONG
PERIMETER OF CAP. PRIME AND PAINT BLACK.
QUADRUPLEX WEATHERPROOF WHILE IN USE OUTLET COVER WITH
STAINLESS STEEL LOCKING MECHANISM FLUSH IN HINGED COVER
EQUAL TO INTERMATIC #WP1010MC WITH DOUBLE GFCI BASE
CONFIGURATION. PAINT COVER TO MATCH STEEL TUBE.
WELD 1/4" STEEL NUT ONTO THE INSIDE FACE OF THE STEEL TUBE
OPPOSITE THE CONVENIENCE RECEPTACLES FOR ATTACHING
SYSTEM GROUND WIRING.
STUB UNDERGROUND CONDUITS 2" ABOVE FINISHED GRADE INSIDE
STEEL TUBE.
CLASS 'A' CONCRETE (3000 PSI).
TWO 3"x6"x3/16" STEEL PLATES (ONE EACH SIDE) WELDED TO THE
BASE OF THE STEEL TUBE.
1" WASHED RIVER ROCK.
PROVIDE 1/8" THICK BITUMINOUS COATING ON THE INSIDE AND
OUTSIDE OF THE STEEL TUBE AS INDICATED. WRAP THE OUTSIDE OF
THE TUBE WITH 10 MIL PLASTIC TAPE, HALF LAPPED.
OUTLINE OF WEATHERPROOF COVER.
OUTLINE OF QUADRA-PLEX GFCI CONVENIENCE RECEPTACLE FORM.
OUTLINE OF RECTANGULAR HOLE IN THE STEEL TUBE FOR QUADRA-
PLEX GFCI CONVENIENCE RECEPTACLE.
DRILL AND TAP HOLES IN STEEL TUBE FOR MOUNTING RECEPTACLES
AND WEATHERPROOF COVER.
CONTRACTOR IS TO STAMP CORRECT CIRCUIT NUMBER DIRECTLY ON
THE TOP OF EACH RECEPTACLE PEDESTAL WITH 1/2" LETTERS.
SECTION A SECTION A
SECTION B FRONT ELEVATION
(WEATHERPROOF COVER INSTALLED)
FRONT ELEVATION
(WEATHERPROOF COVER OFF)
P-? P-?
4 3
BB
AA
CAST METAL
"WHILE-IN-USE"
WP COVER(S) &
RECEPTACLE(S)
RIGID STEEL
CONDUIT FOR
SUPPORT PER N.E.C.
ART. 314
RIGID STEEL
CONDUIT FOR
WIRING
SECTION "A-A"
CAST METAL, 2-GANG, NEMA 3R
JUNCTION BOX WITH THREADED
HUBS.
A
A
ROOF PENETRATION
AND CONDUIT SUPPORT
DETAIL THIS SHEETELEVATION
" M
AX
[46
0 m m]
[30 5 m m]
PERGOLA BEAM
4" x 4" x 2.5" JUNCTION BOX
LIGHT FIXTURE 'S10'
8" 7-1/2"
DETAIL NOTES:
1. LIGHT FIXTURE TO BE AIMED DOWNWARD.
JUNCTION BOX TO BE INSTALLED IN PRE-CUT
POCKET AT END OF BEAM AND FED BY PRE-
INSTALLED 1/2" CONDUIT THAT RUNS THROUGH
CENTER OF BEAM. COORDINATE BEAM DETAILS
WITH ARCHITECTURAL PRIOR TO WORK.
2.
PROVIDE TWISTLOCK
RECEPTACLE AND
PLUG. MOUNT ON
JOIST OR UNISTRUT
JOIST
KELLUM GRIP
UNISTRUT ATTACHED
TO CEILING JOIST
COORDINATE RECEPTACLE TYPE
WITH EQUIPMENT REQUIREMENTS
KELLUM GRIP
PROVIDE CORD LENGTH THAT IS
COORDINATED WITH EQUIPMENT
CONNECTIONS.
277V
LINE
277V-24V TRANSFORMER
FUNCTIONAL DEVICES, #TR20VA004
OR EQUIVALENT
MOUNTED IN JBOX WITHIN
ACCESSIBLE CEILING SPACE
LIGHTING CONTROL
POWER PACK/RELAY FOR
INDICATOR LIGHT
CONTROL, 1 MINUTE
TIMEOUT
LIGHTING CONTROL
POWER PACK/RELAY FOR
GENERAL ROOM
LIGHTING, 5 MINUTE
TIMEOUT
277V
LINE
LIGHTING CONTROL
2 POLE CEILING
MOUNTED DUAL
TECHNOLOGY
OCCUPANCY SENSOR
OCCUPANCY INDICATOR LIGHT
MOUNTED ABOVE DOOR
GENERAL ROOM
LIGHTING
277V
TO LIGHTING
FIXTURE
24V SECONDARY
TO INDICATOR
LIGHT
277V PRIMARY TO
TRANSFORMER
LOW VOLTAGE
CONTROL
LOW VOLTAGE
CONTROL
NOTE
DETAIL IS DIAGRAMMATIC. INSTALL PER LIGHTING
CONTROL MANUFACTURER SPECIFICATIONS.
1. COORDINATE WITH VENDOR TO OMIT THIN WALL KNOCKOUTS SHOWN. PROVIDE PENETRATIONS TO ACCOMMODATE DUCT BANKS AS DETAILED ON
UNDERGROUND COORDINATION PLAN.
2. COORDINATE WITH VENDOR TO PROVIDE PULLING IRONS ON EACH WALL OPPOSITE CONDUIT ENTRIES. IRONS SHALL BE RATED FOR AT LEAST
10,000LBS PULLING FORCE MINIMUM.
3. CONTRACTOR SHALL PROVIDE FIBERGLASS CABLE MANAGEMENT LADDERS COMPATIBLE WITH THE VENDOR-SUPPLIED CABLE MANAGEMENT SYSTEM. SECURE ALL CABLES TO THE LADDERS TO PREVENT MOVEMENT, INCLUDING MOVEMENT RESULTING FROM FAULT CONDITIONS.
4. EQUIVALENT EQUIPMENT FROM APPROVED MANUFACTURERS IS ACCEPTABLE, PER DIV 26 SPECIFICATIONS.
NOTES :
SHEET NUMBER
PROJECT NUMBER
SEALS AND SIGNATURES
ISSUED FOR DATE
Pl ot
Da te:
IHS Whiteriver Hospital 200 W Hospital Drive Whiteriver, Arizona, 85941
IHS Project #: 131445 IHS Contract #: 75H70123R00008 IHS Award Date: 02/02/2024
455 NORTH THIRD STREET
SUITE 250
PHOENIX, AZ 85004
602.265.2200 smithgroup.com
Drawn By: Checked By:
BASED ON PROGRAM OF REQUIREMENTS DATED [ 03/26/22],
POR AMENDMENT DATED [ 02/03/25], AND ON SCHEMATIC
DRAWINGS APPROVED [11/19/24].
6/1 8/2
6 3
:48 :07
P M
ELECTRICAL DETAILS
E6.0.6CD
W hit tin gto n
14904.000 Whittington Baca
SCALE: NONE1 SITE LIGHTING POLE AND POLE BASE DETAIL
SCALE: NONE2 QUADPLEX RECEPTACLE PEDESTAL DETAIL
SCALE: N.T.S.3 ROOF RECEPTACLE MOUNTING DETAIL
SCALE: N.T.S.4 PERGOLA BEAM MOUNTED LIGHT FIXTURE DETAIL
SCALE: NONE5 DROP CORD DETAIL
SCALE: NONE6 OCCUPANCY INDICATOR LIGHT WIRING DETAIL
FINAL CONSTRUCTION DOCUMENTS 23JAN26
BID ADDENDUM-H 18JUN26
SCALE: NONE7 GENERATOR FEEDER MANHOLE DETAIL
H
PT10
PT10
DB5
PT33
PT33
PT33
PT33
ST
-X
SL
J J
J J
J J
J J
PT10
J
J J
J J
JJ
J
JJ
J
PT33
PT33
DB5
DB5
DB5
PT33
PT33
DB5
PT33 PT33 PT33 PT33
PT33
PT33
PT33
PT33
PT33
DB5
PT33 PT33 PT33 PT33
PT33
PT33
PT33
PT33
PT33
DB4
DB4 DB4
DB4
PT33
PT33
PT33
PT33
PT33
PT33
J J
JJ J
JJ
JJJJ
EQUIPMENT ALCOVE
WIS-2287A
TOILET/SHOWER, PATIENT
WIS-2287C
LDRP
WIS-2287
H-11A
H-12
STANDBY
CIRCUIT 1
CRITICAL
CIRCUIT 1
CRITICAL
CIRCUIT 2
STANDBY
CIRCUIT 2
STANDBY
CIRCUIT 3
CRITICAL
CIRCUIT 3
STANDBY
CIRCUIT 4
H
H
OR
SUR-2272
H-16
IPP1A IPP1C
+44"
+44"
+36"
+36"
+44" +44" +44"
+44"
+44"
+44"
+44"
+44"
E602E603 E604
E601
+44"
IPP1B
IPP1A- 1,3
E254
+44"
+36"
+36"
IPP1A- 1,3
IPP1A- 1,3
IPP1A- 1,3
IPP
1A
- 5 ,7
IPP
1A
- 9 ,11
IPP1A- 9,11
IPP1A- 9,11
IPP1A- 13,15
IPP1A- 9,11
IPP1A- 2,4
IPP
1A
- 2 ,4
IPP
1A
- 6 ,8
IPP
1A
- 2 ,4
IPP
1A
- 2 ,4
IPP1A- 10,12
+44" +72"
IPP
1A
- 2 ,4
IPP1A- 14,16
+36" +36"
+36" +24" +36"
IPP1C- 1,3
IPP1B- 1,3
IPP1C- 1,3
IPP1B- 1,3
IPP1B- 1,3
IPP1C- 6,8 IPP1B- 6,8
IPP1C- 2,4IPP1B- 2,4
IPP1B- 14,16IPP1C- 17,19
IPP1B- 13,15 IPP1C- 13,15
IPPLE- 1,3
IPP1B- 10,12
IPP1B- 9,11 IPP1C- 9,11
IPP1B- 5,7 IPP1C- 5,7
IPP1C- 14,16IPP1C- 10,12
IPP1B- 17,19
IPP1B- 22,24IPP1B- 18,20
IPP1C- 18,20
PREP/PACU STAGE 1
SUR-2263
PREP/PACU STAGE 1
SUR-2262
H-15
H-15
STANDBY
CIRCUIT 1
STANDBY
CIRCUIT 2
STANDBY
CIRCUIT 3
CRITICAL
CIRCUIT 1
CRITICAL
CIRCUIT 2
SIM LAB
LAB-2191
H-01
BPE2SLA
BPE2CLA
H-21
+44"
+44"
EXAM, BLOOD DRAW
PVM-2117
EXAM, TRADITIONAL MEDICINE
PVM-2114
+48"
BPE2SLC
BPE1ELB- 63
BPE1ELB- 63
BPE2SLC
41+36"
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
SEE DRAWING E0.1 FOR ABBREVIATIONS, SYMBOLS, GENERAL
NOTES AND DEVICE MOUNTING HEIGHT OF WALL MOUNTED
DEVICES, UON.
ALL BRANCH CIRCUIT WIRING SHALL BE A MINIMUM SIZE OF #10
AWG. REFER TO SHEET E0.2 FOR ADDITIONAL SIZING
INFORMATION.
COORDINATE ALL DEVICE LOCATIONS AND MOUNTING HEIGHTS
WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN.
COORDINATE ALL HEADWALL DEVICE LOCATIONS WITH
ARCHITECTURAL HEADWALL ELEVATIONS PRIOR TO ROUGH-IN.
THE CONTRACTOR SHALL COORDINATE EXACT LOCATION OF
EQUIPMENT POWER CONNECTIONS WITH EQUIPMENT INSTALLER
PRIOR TO ROUGH-IN.
CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING ANY
REQUIRED TRANSFORMER/POWER SUPPLIES FOR DOOR
HARDWARE. COORDINATE WITH ARCHITECTURAL AND SECURITY
DRAWINGS FOR DOOR HARDWARE. PROVIDE 120V POWER AS
REQUIRED.
CONTRACTOR SHALL COORDINATE AND FIELD VERIFY
REQUIREMENT OF NEUTRAL CONDUCTOR FOR ALL EQUIPMENT
AND PROVIDE NEUTRAL CONDUCTOR AS NECESSARY.
ALL CIRCUITS SHALL HAVE DEDICATED NEUTRAL CONDUCTOR,
UNLESS NOTED OTHERWISE.
ALL CONDUCTORS SHALL BE COPPER, UNLESS NOTED OR
SCHEDULED OTHERWISE.
TRIPPING OF GFCI RECEPTACLES SHALL NOT AFFECT THE
DOWNSTREAM RECEPTACLES.
NO MORE THAN 3 CIRCUITS MAY SHARE A HOMERUN.
PROVIDE 120V CIRCUITS FOR CONTROL PANELS AS REQUIRED
BY CONTROL VENDOR. CIRCUIT TO MECHANICAL PANEL WITHIN
THE SPACE.
ALL UNUSED WALL OUTLETS TO BE COVERED WITH BLANK
PLATE. ALL BLANK PLATE COLORS TO MATCH WALL COLOR.
REFER TO 'T' SERIES PLANS FOR LOW VOLTAGE BACK BOX AND
RACEWAY REQUIREMENTS.
ALL CONDUIT ROUTED WITHIN SLAB SHALL COMPLY WITH
GUIDELINES LISTED IN STRUCTURAL DRAWINGS.
FOR DEVICES LABELED WITH RECTANGULAR TAG, REFER TO
KITCHEN EQUIPMENT SCHEDULE ON E7 SERIES FOR
CONNECTIONS, CIRCUITS AND DEVICE TYPES.
WALL MOUNTED AND SUSPENDED TRANSFORMERS SHALL BE
MOUNTED SUCH THAT THE TRANSFORMER ENCLOSURE AND ALL
ELEMENTS OF THE HANGER SUPPORT SYSTEM ARE LOCATED
ABOVE THE MINIMUM WORKING SPACE HEIGHT IN COMPLIANCE
WITH NEC 110.26.
TAMPER RESISTANT RECEPTACLES SHALL BE PROVIDED IN
COMPLIANCE WITH 2023 NEC ARTICLES 406.18 AND 517.18(C) AND
IN LOCATIONS DEEMED PRUDENT FOR SAFE FACILITY
OPERATION. ENGINEER SHALL PROVIDE DOCUMENTATION
INDICATING AREAS REQUIRING TAMPER RESISTANT
RECEPTACLES DURING SUBMITTAL PROCESS.
ELECTRICAL ROOM & UPS ROOM PERSONNEL DOORS SHALL
SWING OUTWARD AND BE EQUIPPED WITH LISTED PANIC
HARDWARE OR LISTED FIRE EXIT HARDWARE.
EXTEND LINE SIDE OF NEAREST 120V GENERAL RECEPTACLE
POWER CIRCUIT TO ELECTRONIC PLUMBING VALVES.
COORDINATE ELECTRONIC PLUMBING VALVE INFRASTRUCTURE
REQUIREMENTS AND LOCATION WITH PLUMBING CONTRACTOR
AND EQUIPMENT MANUFACTURER PRIOR TO COMMENCING
WORK. INSTALL PER EQUIPMENT MANUFACTURERS
SPECIFICATIONS.
DUPLEX RECEPTACLE SHOWN AT +90" IN PATIENT CARE AREAS
IS INTENDED TO SERVE MOTORIZED PATIENT LIFT. COORDINATE
MOUNTING LOCATION AND VERIFY REQUIREMENTS WITH
EQUIPMENT INSTALLER PRIOR TO ROUGH-IN.
PROVIDE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION
FOR PERSONNEL IN A READILY ACCESSIBLE LOCATION FOR
EACH RECEPTACLE LOCATED IN THE AREAS REQUIRED BY NEC
210.8(B).
GENERAL SHEET NOTES
EXAM, IOS
PVM-2109
+48"
+36"
+90"
21BPE1ELB- 65
BPE2SLC
BPE2CLA- 1,3,5,7 BPE2CLA- 9,11,13,15
BPE2CLA- 17
BPE2CLA- 19
APW2LLA- 14
TYP
E259
TYP
E260
BPE2SLA- 30
BPE2SLA- 30
BPE2SLA- 30
BPE2SLA- 32
BP
E2
SL
A-
APW2LLA- 14
TYP
E262
AP
W2
LL
A-
AP
W2
LL
A-
AP
W2
LL
A-
AP
W2
LL
A-
CONTROL ROOM
SEC-2146
SHEET NUMBER
PROJECT NUMBER
SEALS AND SIGNATURES
ISSUED FOR DATE
Pl ot
Da te:
IHS Whiteriver Hospital 200 W Hospital Drive Whiteriver, Arizona, 85941
IHS Project #: 131445 IHS Contract #: 75H70123R00008 IHS Award Date: 02/02/2024
455 NORTH THIRD STREET
SUITE 250
PHOENIX, AZ 85004
602.265.2200 smithgroup.com
Drawn By: Checked By:
BASED ON PROGRAM OF REQUIREMENTS DATED [ 03/26/22],
POR AMENDMENT DATED [ 02/03/25], AND ON SCHEMATIC
DRAWINGS APPROVED [11/19/24].
6/1 8/2
6 3
:48 :20
P M
ENLARGED / TYPICAL
ROOM POWER PLANS -
SECOND LEVEL (UPPER
GROUND)
E6.2.4CD
W hit tin gto n
14904.000 Whittington Baca
SHEET KEYNOTES
E254 COORDINATE EXACT LOCATION OF FLOOR DEVICE WITH
EQUIPMENT PROVIDER PRIOR TO ROUGH-IN.
E259 PROVIDE FLUSH MOUNTED JUNCTION BOX WITH SPECIFIED
CIRCUIT TO SERVE GENERATOR ANNUNCIATOR PANEL.
MOUNT AT +54" AFF. COORDINATE MOUNTING LOCATION
WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN.
E260 PROVIDE FLUSH MOUNTED JUNCTION BOX WITH SPECIFIED
CIRCUIT TO SERVE ATS ANNUNCIATOR PANEL. MOUNT AT
+38" AFF. COORDINATE MOUNTING LOCATION WITH
EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN.
E262 PROVIDE FLUSH MOUNTED JUNCTION BOX WITH SPECIFIED
CIRCUIT TO SERVE SYSTEMS PANEL. COORDINATE
MOUNTING LOCATION WITH EQUIPMENT SUPPLIER PRIOR TO
ROUGH-IN.
E601 PROVIDE SURGICAL LASER OUTLET MODULE WITH INTEGRAL
REMOTE LINE ISOLATION MONITOR AND ANNUNCIATOR, PG
LIFELINK, #DLO-R, EQUIVALENT. DEVICE SHALL BE SERVED
BY PANEL IPPLE AND INSTALLED PER MANUFACTURER
SPECIFICATIONS.
E602 ALL BRANCH CIRCUIT CONDUCTORS ORIGINATING FROM
ISOLATED POWER PANELS SHALL BE TYPE XHHW-2, AND IN
COMPLIANCE WITH 2023 NEC ARTICLE 517.160. BRANCH
CIRCUITS SHALL BE ROUTED FROM ISOLATED POWER PANEL
TO ELECTRICAL DEVICE AS DIRECT AS POSSIBLE, AND WITH
NO SPLICES OR PULLING COMPOUND.
E603 PROVIDE DUPLEX ISOLATED POWER PANEL SYSTEM,
(2)10KVA 480V/1PH-120V, (32) BRANCH CIRCUITS TOTAL, PGE
LIFELINK #IPX-P, OR EQUIVALENT.
E604 PROVIDE ISOLATED POWER PANEL SYSTEM, 10KVA
480V/1PH-120V, (16) BRANCH CIRCUITS, PGE LIFELINK #IPP-P,
OR EQUIVALENT.
SCALE: 1/4" = 1'-0"1 BEDROOM, LDRP POWER PLAN
SCALE: 1/4" = 1'-0"2 LARGE PROCEDURE, OR POWER PLAN
SCALE: 1/4" = 1'-0"4 RECOVERY STAGE 1 POWER PLAN
SCALE: 1/4" = 1'-0"3 SIM LAB POWER PLAN
SCALE: 1/4" = 1'-0"5 EXAM BLOOD DRAW & TRADITIONAL MEDICINE POWER PLAN
SCALE: 1/4" = 1'-0"6 EXAM, IOS POWER PLAN
SCALE: 1/4" = 1'-0"7 CONTROL ROOM SEC-2146
FINAL CONSTRUCTION DOCUMENTS 23JAN26
BID ADDENDUM-H 18JUN26
L2D
DT
D
L2 D
DT
D
ME
D
L1 D
W C
WC
INV
LDRP
WIS-2287
TOILET/SHOWER, PATIENT
WIS-2287C
EQUIPMENT ALCOVE
WIS-2287A
DD1 D1
D3
D3
D3
D3
B1 c,d c,d g g d d
RR1
A6
A1 F1F
F1F
GG1
GG1
D3
D3
D3
D3
D3
NL
NL
D3
D3
H-11A a a a b b c c e e c d d e,f,g f
H-12
EXTEND UNSWITCHED LEG
OF CRITICAL LTG CIRCUIT
TO NIGHT LIGHTS.
E614
E615
E322 b e b
A1 AUTOMATIC ON/OFF, 100% OUTPUT, 5 MINUTE TIME-OUT
A2 AUTOMATIC ON/OFF, 50% OUTPUT, 5 MINUTE TIME-OUT
A3 AUTOMATIC ON/OFF, 50% OUTPUT, 10 MINUTE TIME-OUT
A4 AUTOMATIC ON/OFF, 50% OUTPUT, 20 MINUTE TIME-OUT
A5 AUTOMATIC ON/OFF, 100% OUTPUT, 10 MINUTE TIME-OUT
A6 AUTOMATIC ON/OFF, 100% OUTPUT, 20 MINUTE TIME-OUT
M1 MANUAL ON, AUTOMATIC OFF, 100% OUTPUT, 5 MINUTE TIME-OUT
M2 MANUAL ON, AUTOMATIC OFF, 100% OUTPUT, 10 MINUTE TIME-OUT
M3 MANUAL ON, AUTOMATIC OFF, 100% OUTPUT, 20 MINUTE TIME-OUT
SENSOR PROGRAMMING
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
SEE DRAWING E0.1 FOR ABBREVIATIONS, SYMBOLS, AND
GENERAL NOTES.
SEE LIGHTING AND LIGHTING CONTROL SCHEDULES / SoO, E7
SERIES PLANS FOR ADDITIONAL NFORMATION.
COORDINATE ALL DEVICE LOCATIONS AND MOUNTING HEIGHTS
WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN.
ALL CIRCUITS SHALL HAVE DEDICATED NEUTRAL CONDUCTOR,
UNLESS NOTED OTHERWISE.
ALL LIGHTING BRANCH CIRCUIT WIRING SHALL BE A MINIMUM
SIZE OF #10 AWG. REFER TO SHEET E0.2 FOR ADDITIONAL
SIZING INFORMATION.
ALL CONDUCTORS SHALL BE COPPER, UNLESS NOTED OR
SCHEDULED OTHERWISE.
WHERE EMERGENCY LIGHTING FIXTURES SERVED FROM LIFE
SAFETY OR CRTICAL BRANCH POWER ARE CONNECTED TO A
COMMON LIGHTING CONTROL ZONE WITH LIGHT FIXTURES
SERVED FROM OTHER BRANCHES OF POWER, A UL924
AUTOMATIC TRANSFER DEVICE SHALL BE PROVIDED.
EMERGENCY LIGHTING FIXTURES SHALL BE CONTROLLED BY
SPECIFIED LIGHTING CONTROL DEVICE WHEN NORMAL UTILITY
POWER IS AVAILABLE AND TRANSFER TO RESPECTIVE
EMERGENCY BRANCH POWER UPON LOSS OF NORMAL POWER.
LIGHTING CONTROL DEVICE SHALL BE OVERRIDDEN UPON
TRANSFER TO EMERGENCY BRANCH POWER FOR 100%
LIGHTING FIXTURE OUTPUT. PROVIDE QUANTITY OF DEVICES,
ALL ACCESSORIES AND WIRING REQUIRED PER
MANUFACTURER'S SPECIFICATIONS. LOCATE TRANSFER
DEVICE IN AN ACCESSIBLE LOCATION. LOCATION SHALL BE
REFLECTED IN AS-BUILT DOCUMENTATION.
LOWERCASE ALPHABETICAL SUBSCRIPT ON FIXTURES/DEVICES
INDICATES SWITCHING ZONE WITHIN SPACE.
WHERE MORE THAN ONE SWITCH IS SHOWN AT ANY ONE
LOCATION, GANG ALL SWITCHES UNDER ONE PLATE. PROVIDE
BARRIERS BETWEEN SWITCHES CONNECTED TO DIFFERENT
CIRCUITS. WHERE MORE THAN ONE DIMMER IS SHOWN AT ANY
ONE LOCATION, MOUNT IN A MANNER TO GIVE THE
APPEARANCE OF GANG MOUNTED UNDER ONE PLATE. FOLLOW
MANUFACTURERS INSTRUCTIONS FOR DISTANCES AND
DERATING.
COORDINATE FIXTURES WITH ARCHITECTURAL CEILING AND
WALL TYPES.
ARCHITECT HAS FINAL APPROVAL OVER ALL FINISHES.
FOR ALL CEILING MOUNTED OCCUPANCY SENSORS AND EXIT
SIGNS MOUNTED IN OPEN CEILINGS, LOCATE AT HEIGHT SO
THAT TOP OF DEVICE IS ALIGNED WITH LOWEST ADJACENT
CEILING TO MAINTAIN INTENDED OPERATIONAL RANGE AND
VISIBILITY.
WHERE GENERAL PURPOSE RECEPTACLES ARE SHOWN WITHIN
2' OF A LIGHTING CONTROL DEVICE, ALIGN DEVICES
VERTICALLY IN ELEVATION. COORDINATE LOCATIONS OF
MECHANICAL THERMOSTATS AND ALIGN WITH LIGHTING
CONTROL.
FOR ALL LIGHTING CONTROL DEVICE SYMBOLS SHOWN ON
PLANS, SEE SHEET E0.1 FOR LIGHTING CONTROL DESCRIPTION
AND TYPE/FUNCTIONALITY OF DEVICE(S) TO BE PROVIDED
WITHIN ROOM. FOR ALL LOW VOLTAGE WALL SWITCH DIMMERS,
PROVIDE SEPARATE BUTTONS FOR EACH DIMMING ZONE TO
ALLOW FULL RANGE DIMMING OF EACH ZONE.
FIELD COORDINATE LIGHT FIXTURE LOCATIONS IN ELECTRICAL,
MECHANICAL AND TELECOM ROOMS WITH EQUIPMENT, DUCTS,
PIPING, TELECOM, SECURITY, AND ALL UTILITIES IN SPACE.
EXIT SIGNS ARE REQUIRED TO BE READILY VISIBLE. ENSURE
THE EXIT SIGNS ARE NOT OBSTRUCTED.
ALL EXIT SIGNS ARE TYPE "X1" UNLESS NOTED OTHERWISE.
EXIT SIGNS SHALL BE CONNECTED TO UNSWITCHED LEG OF
SPECIFIED CIRCUIT.
PROVIDE CENTRALIZED CONTROL OF ALL LIGHTING IN
BUILDING WITH ALL REQUIRED ACCESSORIES AND SOFTWARE
FOR REMOTE CONTROLLABILITY/MANAGEMENT AND
MONITORING OF ALL LIGHTING. ALL CONTROL PANELS WITHIN
PROJECT TO TIE INTO CENTRAL SYSTEM SOFTWARE.
SOFTWARE TO BE INSTALLED ON DEVELOPER'S COMPUTERS.
QUANTITY AND LOCATION OF SOFTWARE INSTALL AS
REQUIRED OR DIRECTED BY DEVELOPER.
PROVIDE CONTROL TIE-IN TO BMS FROM LIGHTING CONTROL
SYSTEM. PROVIDE ALL SOFTWARE AND DATA CONNECTIONS
FOR TIE-IN AS REQURED BY SELECTED MANUFACTURER. FINAL
LOCATION TO BE DETERMINED BY DEVELOPER.
COMMON AREA CONTROL ZONES OUTLINED WITH DASHED LINE
ARE TO BE CONTROLLED BY RELAY PANEL WITH OCCUPANCY
SENSORS TO ACTIVATE LIGHTING AFTER HOURS. OCCUPANCY
SENSORS SHALL ACTIVATE ALL LIGHTING WITHIN MARKED
CONTROL ZONE. REFER TO LIGHTING CONTROL SCHEDULE
AND MATRIX ON E7 SHEETS FOR ADDITIONAL INFORMATION.
AT ALL IN-PATIENT BED LOCATIONS, PROVIDE INTERFACE
FROM OVER-BED LIGHTING FIXTURE(S) TO PILLOW SWITCH
CONTROLLER, FOR CONTROL OF AMBIENT AND READING
FUNCTIONS. PROVIDE ALL NECESSARY HARDWARE AND
CONNECTIVITY FOR A FUNCTIONAL SYSTEM
GENERAL SHEET NOTES
SHEET NUMBER
PROJECT NUMBER
SEALS AND SIGNATURES
ISSUED FOR DATE
Pl ot
Da te:
IHS Whiteriver Hospital 200 W Hospital Drive Whiteriver, Arizona, 85941
IHS Project #: 131445 IHS Contract #: 75H70123R00008 IHS Award Date: 02/02/2024
455 NORTH THIRD STREET
SUITE 250
PHOENIX, AZ 85004
602.265.2200 smithgroup.com
Drawn By: Checked By:
BASED ON PROGRAM OF REQUIREMENTS DATED [ 03/26/22],
POR AMENDMENT DATED [ 02/03/25], AND ON SCHEMATIC
DRAWINGS APPROVED [11/19/24].
6/1 8/2
6 3
:48 :24
P M
ENLARGED / TYPICAL
ROOM LIGHTING PLANS -
SECOND LEVEL (UPPER
GROUND)
E6.2.5CD
W hit tin gto n
14904.000 Whittington Baca
SHEET KEYNOTES
E322 PROVIDE EMERGENCY INVERTER MYERS ILLUMINATOR
LVM-250-G OR EQUIVALENT. INVERTER SHALL INTERFACE
WITH BIRTHING LIGHT SYSTEM. WHEN BIRTHING LIGHTS ARE
IN USE (ON) AND UNDER A LOSS OF UTILITY POWER,
INVERTER SHALL PROVIDE BATTERY POWER TO MAINTAIN
LIGHTING OUTPUT UNTIL THE GENERATOR SYSTEM HAS
BEEN ESTABLISHED AS THE POWER SOURCE. THE INVERTER
SHALL NOT OVERRIDE CONTROL AND SHALL NOT
ILLUMINATE BIRTHING LIGHTS WHEN THE SYSTEM IS NOT IN
USE (OFF).
E614 PROVIDE REQUIRED WALL CONTROL PANEL (KIRLIN
PRO-WALLC) FOR BIRTHING LIGHTS. COORDINATE LOCATION
PRIOR TO ROUGH IN.
E615 PROVIDE REMOTE SENSOR (KIRLIN PRO-SENSR) FOR
BIRTHING LIGHTS.
SCALE: 1/4" = 1'-0"1 BEDROOM / LDRP LIGHTING PLAN
FINAL CONSTRUCTION DOCUMENTS 23JAN26
BID ADDENDUM-H 18JUN26
H
H
DT
D
L2D
L2 D
ME
D
L1 D
VAN VAN VAN
10 MIN
OUTREACH
STAFF
10 MIN
OUTREACH
STAFF
10 MIN
OUTREACH
STAFF
VAN VAN VAN
10 MIN
OUTREACH
STAFF
10 MIN
OUTREACH
STAFF
PUMP PUMP
D2
L2 D
ME
D
DT
D
L4D
L1D
DD1
D1 D1
(TYP)
F1
(TYP)
BB1
b,c a b,c c c c b b a a
PATIENT ROOM, AII/IOS/ACC
IPC-3249
TOILET/SHOWER, PATIENT, IOS
IPC-3249A
NL
EXTEND UNSWITCHED LEG
OF CRITICAL LTG CIRCUIT
TO NIGHT LIGHTS
NL
H c c
(TYP)
G1
EXAM
PCC-3176
OL
E318 a,b a a aa b a
PATIENT ROOM
IPC-3264
TOILET/SHOWER, PATIENT
IPC-3264A
(TYP)
F1
(TYP)
BB1
(TYP)
BB1
a c,d a a b b dd
D1
D1 DD1
A6
NL
EXTEND UNSWITCHED LEG
OF CRITICAL LTG CIRCUIT
TO NIGHT LIGHTS
NL
H-21 b,c,d b c
BB1
A1 AUTOMATIC ON/OFF, 100% OUTPUT, 5 MINUTE TIME-OUT
A2 AUTOMATIC ON/OFF, 50% OUTPUT, 5 MINUTE TIME-OUT
A3 AUTOMATIC ON/OFF, 50% OUTPUT, 10 MINUTE TIME-OUT
A4 AUTOMATIC ON/OFF, 50% OUTPUT, 20 MINUTE TIME-OUT
A5 AUTOMATIC ON/OFF, 100% OUTPUT, 10 MINUTE TIME-OUT
A6 AUTOMATIC ON/OFF, 100% OUTPUT, 20 MINUTE TIME-OUT
M1 MANUAL ON, AUTOMATIC OFF, 100% OUTPUT, 5 MINUTE TIME-OUT
M2 MANUAL ON, AUTOMATIC OFF, 100% OUTPUT, 10 MINUTE TIME-OUT
M3 MANUAL ON, AUTOMATIC OFF, 100% OUTPUT, 20 MINUTE TIME-OUT
SENSOR PROGRAMMING
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
SEE DRAWING E0.1 FOR ABBREVIATIONS, SYMBOLS, AND
GENERAL NOTES.
SEE LIGHTING AND LIGHTING CONTROL SCHEDULES / SoO, E7
SERIES PLANS FOR ADDITIONAL NFORMATION.
COORDINATE ALL DEVICE LOCATIONS AND MOUNTING HEIGHTS
WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN.
ALL CIRCUITS SHALL HAVE DEDICATED NEUTRAL CONDUCTOR,
UNLESS NOTED OTHERWISE.
ALL LIGHTING BRANCH CIRCUIT WIRING SHALL BE A MINIMUM
SIZE OF #10 AWG. REFER TO SHEET E0.2 FOR ADDITIONAL
SIZING INFORMATION.
ALL CONDUCTORS SHALL BE COPPER, UNLESS NOTED OR
SCHEDULED OTHERWISE.
WHERE EMERGENCY LIGHTING FIXTURES SERVED FROM LIFE
SAFETY OR CRTICAL BRANCH POWER ARE CONNECTED TO A
COMMON LIGHTING CONTROL ZONE WITH LIGHT FIXTURES
SERVED FROM OTHER BRANCHES OF POWER, A UL924
AUTOMATIC TRANSFER DEVICE SHALL BE PROVIDED.
EMERGENCY LIGHTING FIXTURES SHALL BE CONTROLLED BY
SPECIFIED LIGHTING CONTROL DEVICE WHEN NORMAL UTILITY
POWER IS AVAILABLE AND TRANSFER TO RESPECTIVE
EMERGENCY BRANCH POWER UPON LOSS OF NORMAL POWER.
LIGHTING CONTROL DEVICE SHALL BE OVERRIDDEN UPON
TRANSFER TO EMERGENCY BRANCH POWER FOR 100%
LIGHTING FIXTURE OUTPUT. PROVIDE QUANTITY OF DEVICES,
ALL ACCESSORIES AND WIRING REQUIRED PER
MANUFACTURER'S SPECIFICATIONS. LOCATE TRANSFER
DEVICE IN AN ACCESSIBLE LOCATION. LOCATION SHALL BE
REFLECTED IN AS-BUILT DOCUMENTATION.
LOWERCASE ALPHABETICAL SUBSCRIPT ON FIXTURES/DEVICES
INDICATES SWITCHING ZONE WITHIN SPACE.
WHERE MORE THAN ONE SWITCH IS SHOWN AT ANY ONE
LOCATION, GANG ALL SWITCHES UNDER ONE PLATE. PROVIDE
BARRIERS BETWEEN SWITCHES CONNECTED TO DIFFERENT
CIRCUITS. WHERE MORE THAN ONE DIMMER IS SHOWN AT ANY
ONE LOCATION, MOUNT IN A MANNER TO GIVE THE
APPEARANCE OF GANG MOUNTED UNDER ONE PLATE. FOLLOW
MANUFACTURERS INSTRUCTIONS FOR DISTANCES AND
DERATING.
COORDINATE FIXTURES WITH ARCHITECTURAL CEILING AND
WALL TYPES.
ARCHITECT HAS FINAL APPROVAL OVER ALL FINISHES.
FOR ALL CEILING MOUNTED OCCUPANCY SENSORS AND EXIT
SIGNS MOUNTED IN OPEN CEILINGS, LOCATE AT HEIGHT SO
THAT TOP OF DEVICE IS ALIGNED WITH LOWEST ADJACENT
CEILING TO MAINTAIN INTENDED OPERATIONAL RANGE AND
VISIBILITY.
WHERE GENERAL PURPOSE RECEPTACLES ARE SHOWN WITHIN
2' OF A LIGHTING CONTROL DEVICE, ALIGN DEVICES
VERTICALLY IN ELEVATION. COORDINATE LOCATIONS OF
MECHANICAL THERMOSTATS AND ALIGN WITH LIGHTING
CONTROL.
FOR ALL LIGHTING CONTROL DEVICE SYMBOLS SHOWN ON
PLANS, SEE SHEET E0.1 FOR LIGHTING CONTROL DESCRIPTION
AND TYPE/FUNCTIONALITY OF DEVICE(S) TO BE PROVIDED
WITHIN ROOM. FOR ALL LOW VOLTAGE WALL SWITCH DIMMERS,
PROVIDE SEPARATE BUTTONS FOR EACH DIMMING ZONE TO
ALLOW FULL RANGE DIMMING OF EACH ZONE.
FIELD COORDINATE LIGHT FIXTURE LOCATIONS IN ELECTRICAL,
MECHANICAL AND TELECOM ROOMS WITH EQUIPMENT, DUCTS,
PIPING, TELECOM, SECURITY, AND ALL UTILITIES IN SPACE.
EXIT SIGNS ARE REQUIRED TO BE READILY VISIBLE. ENSURE
THE EXIT SIGNS ARE NOT OBSTRUCTED.
ALL EXIT SIGNS ARE TYPE "X1" UNLESS NOTED OTHERWISE.
EXIT SIGNS SHALL BE CONNECTED TO UNSWITCHED LEG OF
SPECIFIED CIRCUIT.
PROVIDE CENTRALIZED CONTROL OF ALL LIGHTING IN
BUILDING WITH ALL REQUIRED ACCESSORIES AND SOFTWARE
FOR REMOTE CONTROLLABILITY/MANAGEMENT AND
MONITORING OF ALL LIGHTING. ALL CONTROL PANELS WITHIN
PROJECT TO TIE INTO CENTRAL SYSTEM SOFTWARE.
SOFTWARE TO BE INSTALLED ON DEVELOPER'S COMPUTERS.
QUANTITY AND LOCATION OF SOFTWARE INSTALL AS
REQUIRED OR DIRECTED BY DEVELOPER.
PROVIDE CONTROL TIE-IN TO BMS FROM LIGHTING CONTROL
SYSTEM. PROVIDE ALL SOFTWARE AND DATA CONNECTIONS
FOR TIE-IN AS REQURED BY SELECTED MANUFACTURER. FINAL
LOCATION TO BE DETERMINED BY DEVELOPER.
COMMON AREA CONTROL ZONES OUTLINED WITH DASHED LINE
ARE TO BE CONTROLLED BY RELAY PANEL WITH OCCUPANCY
SENSORS TO ACTIVATE LIGHTING AFTER HOURS. OCCUPANCY
SENSORS SHALL ACTIVATE ALL LIGHTING WITHIN MARKED
CONTROL ZONE. REFER TO LIGHTING CONTROL SCHEDULE
AND MATRIX ON E7 SHEETS FOR ADDITIONAL INFORMATION.
AT ALL IN-PATIENT BED LOCATIONS, PROVIDE INTERFACE
FROM OVER-BED LIGHTING FIXTURE(S) TO PILLOW SWITCH
CONTROLLER, FOR CONTROL OF AMBIENT AND READING
FUNCTIONS. PROVIDE ALL NECESSARY HARDWARE AND
CONNECTIVITY FOR A FUNCTIONAL SYSTEM
GENERAL SHEET NOTES
SHEET NUMBER
PROJECT NUMBER
SEALS AND SIGNATURES
ISSUED FOR DATE
Pl ot
Da te:
IHS Whiteriver Hospital 200 W Hospital Drive Whiteriver, Arizona, 85941
IHS Project #: 131445 IHS Contract #: 75H70123R00008 IHS Award Date: 02/02/2024
455 NORTH THIRD STREET
SUITE 250
PHOENIX, AZ 85004
602.265.2200 smithgroup.com
Drawn By: Checked By:
BASED ON PROGRAM OF REQUIREMENTS DATED [ 03/26/22],
POR AMENDMENT DATED [ 02/03/25], AND ON SCHEMATIC
DRAWINGS APPROVED [11/19/24].
6/1 8/2
6 3
:48 :30
P M
ENLARGED / TYPICAL
ROOM LIGHTING PLANS -
THIRD LEVEL
E6.3.4CD
W hit tin gto n
14904.000 Whittington Baca
SHEET KEYNOTES
E318 LIGHT FIXTURE 'OL' IS AN OCCUPANCY INDICATOR LIGHT
INSTALLED ABOVE EXAM ROOM DOORS ON TEAM ROOM
SIDE. PROVIDE 277V-24V TRANSFORMER. USE ASSOCIATED
EXAM ROOM LIGHTING CRITICAL BRANCH CIRCUIT FOR
POWER. REFER TO LIGHT FIXTURE SCHEDULE FOR
ADDITIONAL INFORMATION. REFER TO DETAIL 6 ON SHEET
E6.0.6 AND DETAIL 7 ON SHEET E6.0.15 FOR ADDITIONAL
INFORMATION.
SCALE: 1/4" = 1'-0"1 AII / IOS / ADA PATIENT ROOM LIGHTING PLAN
SCALE: 1/4" = 1'-0"2 EXAM LIGHTING PLAN
SCALE: 1/4" = 1'-0"3 PATIENT ROOM LIGHTING PLAN
FINAL CONSTRUCTION DOCUMENTS 23JAN26
BID ADDENDUM-H 18JUN26
H
H
| E1.1.P1 - ELECTRICAL SITE POWER PLAN PHASE 1 |
| E6.0.6 - ELECTRICAL DETAILS |
| E6.2.4 - ENLARGED / TYPICAL ROOM POWER PLANS - SECOND LEVEL (UPPER GROUND) |
| E6.2.5 - ENLARGED / TYPICAL ROOM LIGHTING PLANS - SECOND LEVEL (UPPER GROUND) |
| E6.3.4 - ENLARGED / TYPICAL ROOM LIGHTING PLANS - THIRD LEVEL |
File details come from the government source that posted it. Updated .