589A7-18-302 Wichita Bid Drawings - 7_Mechanical (SI) 3 of 4.pdf
PDF 7 MB Posted
- Solicitation number
- 36C25522R0079
About this file
This solicitation is for a firm-fixed-price construction contract to install new boilers in Building 13 at the Robert J. Dole VA Medical Center in Wichita, Kansas. The Department of Veterans Affairs, through the Veterans Health Administration and Veterans Integrated Service Network 15, is seeking proposals to remove and replace two existing boilers and associated equipment with three new high-efficiency condensing boilers. Offerors must submit proposals by July 15th, 2022. The period of performance is 270 calendar days following award of the contract, which is expected by September 30th, 2022. The solicitation is designated as a service-disabled veteran-owned small business set-aside.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAIN LEVEL
CATWALK LEVEL
UPPER ROOF -
HIGH POINT
12338
1 2 3 4 5
13-DA-1
254HPS
76HPS
203HPS
38HPS
51HPS
51FWPD 51FWPD
51FWPD
TO 13-B-1
51FWPD
TO 13-B-2
TO 13-B-3
76HPS
13-FWP-3
32HPR
32HPR
PIPING IN
BOILER ROOM TRENCH
38FOR
38FOS
38V
254HPS BYPASS
51FWPD
FUEL-OIL
BACK PRESSURE
VALVE
203HPS
254HPS
38FOR
152 LPS TO
DA
TO STEAM SILENCER
203HPS
CONTROL
ROOM
M-8
BOILER
ROOM
M-18
76CPTD
32HPR 32HPR
(TYP)
508x711 508x711
203HPS TO
NORTH LOOP
203HPS FROM BOILER 3
203HPS BYPASS
FOR NORTH LOOP
203HPS FROM
BOILER #2
203HPS FROM
BOILER #1 3
TO DA
38HPS TO
BUILDING 20
203HPS BYPASS
TO SOUTH LOOP
203HPS
51FWPD
51FWPD
TO BUILDING 12203HPS
254HPS
TO DA
203HPS BYPASS
TO SOUTH LOOP
DA ACCESS
CATWALK
STAIRS
BEYOND
76CPTD
MAIN LEVEL
UPPER ROOF -
HIGH POINT
12338
E1E3
BOILER
ROOM
M-18
152HPS
SAFETY
RELIEF VALVE
152LPS
TO DA
76HPS
REFER TO DETAIL #7
ON DRAWING M-503
76LPS
32HPR
711x508
(N)76HPS
13-SF-1
x
102SV
BOD: MIN 3200
457x457
SG-12
457x457
SG-9
610x610
SG-4
x
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
NO. DESCRIPTION DATE
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER
o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
MR PROJECT NO:
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
C U s e rs
\g s tr o h \D o c u m e n ts
\0 -0
-W ic h it a B o ile rs -M e tr ic M
E P
-C E
N T
R A
L -R g s tr o h Q
H E
Z
.r v t
/9
/2
:4
:5
A
M
13-M-302
MECHANICAL
SECTIONS
INSTALL NEW BOILERS IN
BUILDING 13
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
589A7-18-302
Project Director
2021-09-03 AP GDS0499-0121
100% BID SET
FULLY SPRINKLERED
SCALE: 1 : 481 SECTION @ STEAM HEADER
GENERAL SHEET NOTES:
SHEET KEYNOTES:
1 STEAM MAIN DRIP LEG. REFER TO DETAIL 5 ON DRAWING M-503.
2 PROVIDE DRIP PAN ELBOW PER DETAIL 8 ON DRAWING M-503.
3 203 DIA HPS TO TEMPORARY CONNECTION FOR FUTURE RENTAL BOILER.
4 ALL ISOLATION VALVES MUST BE ACCESSIBLE FROM A WALKABLE SURFACE.
5 152 DIA VALVED SPARE CONNECTION WITH 300# BLIND FLANGE.
6 ALL MAIN STEAM VALVES TO HAVE 25 BYPASS LINE WITH GLOBE VALVE FOR WARM-UP. NOT
SHOWN FOR CLARITY.
7 76 CTPD - DA TANK BYPASS DOWN TO FEEDWATER PUMP SUCTION HEADER.
SCALE: 1 : 482 SECTION @ DA PRV STATION
REF. MP121.02 REF. MP121.02
1. REFER TO DRAWING M-001 FOR NOTES, SYMBOLS AND ABBREVIATIONS.
2. REFER TO DRAWINGS MP601, MP602, MP603 AND MP604 FOR SYSTEM FLOW
DIAGRAMS.
3. REFER TO DRAWINGS M-701, M-702, M-703 AND M-704 FOR EQUIPMENT
SCHEDULES.
4. CONTRACTOR SHALL SUBMIT A DETAILED LOCKOUT/TAGOUT PROCEDURE TO THE VA A
MINIMUM OF 4 WORKING DAYS PRIOR TO PERFORMING ANY WORK ON ANY LIVE
STEAM OR STEAM CONDENSATE SYSTEM OR EQUIPMENT.
5. ALL VALVE HANDLES MUST BE ACCESSIBLE FROM A WALKABLE SURFACE. COORDINATE
LOCATION WITH ALL TRADES.
MAIN LEVEL
CATWALK LEVEL
UPPER ROOF -
LOW POINT
12060
F H KJG
13-CS-1
13-DA-1
102SV152SV
102SV
76FWPD
76FWPD
13-FWP-1
13-FWP-2
13-FWP-3
38V
CATWALK FOR
ACCESS TO DA
PRV STATION
FOR DA
SAFETY RELIEF
VALVE
102PC
102PC
13-UH-5
711x508 x
BOILER
ROOM
M-18
(N)76CPTD
76PC
CTPD
(TANK
BYPASS)
13-EF-1
203HPS
102OFL
610x610
SG-2
457x457
SG-2
BOD: MIN 3200
76CPTD
SHOP LEVEL
TUNNEL LEVEL
-1829
BASEMENT LEVEL
-3454
MAIN LEVEL
CATWALK LEVEL
UPPER ROOF -
LOW POINT
12060
UPPER ROOF
PARAPET
12795
LOW ROOF
PARAPET
4 5 6
NEW PUMP
ROOM
B-3
BOILER
ROOM
M-18
32LPR
13-GRV-3
76PC
TO EXISTING
NORTH LOOP
51FOR
51FOS
203HPS
76V
76V
76NG
BOILER SPOOL PIPE
REFER TO DRAWING
MP601 FOR DETAILS
102PC
152SV
32HPR
x
EQUIPMENT
ROOM
M-17
38FOS
38FOR
13-FOP-1/2
(N)203HPS
13-EF-6
FROM/TO 13-FOP-3/4
FROM/TO 13-FOP-3/4
38FOR
38FOS
(N)76V
(N)127V
203HPS
NON-RETURN VALVE
BOILER STOP VALVE
127V
76SW
FROM MAIN
STEAM HEADER
FROM MAIN
STEAM HEADER
51LPS
13-EF-5
305x305
254x508
610x610
SG-2
457x457
SG-2
x
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
NO. DESCRIPTION DATE
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER
o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
MR PROJECT NO:
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
C U s e rs
\g s tr o h \D o c u m e n ts
\0 -0
-W ic h it a B o ile rs -M e tr ic M
E P
-C E
N T
R A
L -R g s tr o h Q
H E
Z
.r v t
/9
/2
:4
:5
A
M
13-M-303
MECHANICAL
SECTIONS
INSTALL NEW BOILERS IN
BUILDING 13
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
589A7-18-302
Project Director
2021-09-03 AP GDS0499-0121
100% BID SET
FULLY SPRINKLERED
SCALE: 1 : 481 SECTION @ DA & SURGE TANK
GENERAL SHEET NOTES:
SCALE: 1 : 482 SECTION @ 8" HPS DROP TO NORTH LOOP & FUEL OIL PIPING
SHEET KEYNOTES:
1 SLOPE DA OVERFLOW LINE 1/203 PER FT. TOWARDS CONDENSATE SURGE TANK (13-CS-1).
2 102 TANK SURGE TANK BYPASS CONNECT TO CONDENSATE TRANSFER PUMP SUCTION HEADER.
PROVIDE SEPARATE VALVED PIPE TO DRAIN. REFER TO DRAWING MP603 FOR ADDTIONAL
DETAILS.
3 76 CTPD - DA TANK BYPASS DOWN TO FEEDWATER PUMP SUCTION HEADER.
1. REFER TO DRAWING M-001 FOR NOTES, SYMBOLS AND ABBREVIATIONS.
2. REFER TO DRAWINGS MP601, MP602, MP603 AND MP604 FOR SYSTEM FLOW
DIAGRAMS.
3. REFER TO DRAWINGS M-701, M-702, M-703 AND M-704 FOR EQUIPMENT
SCHEDULES.
4. CONTRACTOR SHALL SUBMIT A DETAILED LOCKOUT/TAGOUT PROCEDURE TO THE VA A
MINIMUM OF 4 WORKING DAYS PRIOR TO PERFORMING ANY WORK ON ANY LIVE
STEAM OR STEAM CONDENSATE SYSTEM OR EQUIPMENT.
INTERMEDIATE
ROOF - HIGH
POINT
MAIN LEVEL
CATWALK LEVEL
1 2
13-CS-1
203HPS
610x610
SG-2
1133 L/s x
BOILER
ROOM
M-18
508x711 508x711
102SV
76CPTD
38FOR
152NG
102LPR
(N)76CPTD
(N)152NG
(N)203HPS
(N)25LPR
32LPS
13-CTP-1
BOD: MIN 3200
457x457
SG-2
614 L/s
EXISTING
CATWALK LEVEL
MAIN LEVEL
CATWALK LEVEL
LOW ROOF
PARAPET
HK J
38FOR
38FOS
152NG
76DCW
152HPS
OVERHEAD DOOR
102PC/FWPD
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
NO. DESCRIPTION DATE
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER
o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
MR PROJECT NO:
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
C U s e rs
\g s tr o h \D o c u m e n ts
\0 -0
-W ic h it a B o ile rs -M e tr ic M
E P
-C E
N T
R A
L -R g s tr o h Q
H E
Z
.r v t
/1
/2
:4 :4
P
M
13-M-304
MECHANICAL
SECTIONS
INSTALL NEW BOILERS IN
BUILDING 13
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
589A7-18-302
Project Director
2021-09-03 AP Author0499-0121
100% BID SET
FULLY SPRINKLERED
SCALE: 1 : 481 SECTION @ TEMPORARY BOILER CONNECTIONS
GENERAL SHEET NOTES:
SHEET KEYNOTES:
1 HPS & PC CONNECTIONS FOR FUTURE TEMPORARY BOILER. PROVIDE BLIND FLANGE, VALVE
AND CAP.
SCALE: 1 : 482 ELEVATION VIEW @ TEMPORARY BOILER CONNECTIONS
REF. MP111.02REF. MP111.02
1. REFER TO DRAWING M-001 FOR NOTES, SYMBOLS AND ABBREVIATIONS.
2. REFER TO DRAWINGS MP601, MP602, MP603 AND MP604 FOR SYSTEM FLOW
DIAGRAMS.
3. REFER TO DRAWINGS M-701, M-702, M-703 AND M-704 FOR EQUIPMENT
SCHEDULES.
4. CONTRACTOR SHALL SUBMIT A DETAILED LOCKOUT/TAGOUT PROCEDURE TO THE VA A
MINIMUM OF 4 WORKING DAYS PRIOR TO PERFORMING ANY WORK ON ANY LIVE
STEAM OR STEAM CONDENSATE SYSTEM OR EQUIPMENT.
INTERMEDIATE
ROOF - HIGH
POINT
MAIN LEVEL
CATWALK LEVEL
DCBA
203x864
254x254
152Ø x
13-ERV-2
13-AC-4
203x1372
254x254
457x305
381x381 381x381
203x1372
CONTRACTOR
TOUCHDOWN
M-6
PASSAGE
M-7
TOILET
M-1 x
254x254
152x152
203x152 x x
ER-1
59 L/s
CD-3
47 L/s
CD-4
142 L/s
CD-4
142 L/s RG-3
295 L/s
RG-3
295 L/s
305x305
13-GRV-8 13-GRV-7
x
203x864
MAIN LEVEL
CATWALK LEVEL
UPPER ROOF -
HIGH POINT
12338
203x406
305x356
203x1067
13-AC-3
x
457x203 x
RG-1
106 L/s
CD-2
106 L/s
CD-2
106 L/s
254x1067
192x192
CONTROL
ROOM
M-8
STORAGE
13-42
OFFICE
M-9
LOW ROOF
HIGH ROOF
19CD RL/RS
RL/RS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
NO. DESCRIPTION DATE
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER
o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
MR PROJECT NO:
NORTHKEYPLAN
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
C U s e rs
\g s tr o h \D o c u m e n ts
\0 -0
-W ic h it a B o ile rs -M e tr ic M
E P
-C E
N T
R A
L -R g s tr o h Q
H E
Z
.r v t
/9
/2
:4
:0
A
M
13-M-305
MECHANICAL
SECTIONS
INSTALL NEW BOILERS IN
BUILDING 13
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
589A7-18-302
Project Director
2021-09-03 AP GDS0499-0121
100% BID SET
FULLY SPRINKLERED
SCALE: 1 : 481 SECTION - DUCTWORK PLAN PHASE 3
SCALE: 1 : 482 SECTION - DUCTWORK PLAN PHASE 2
MECHANICAL DETAILS
M-501
GDSMH
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
M-502
GDSMH
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
M-503
GDSMH
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
MECHANICAL
DETAILS
M-504
GDSMH
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
M-505
GDSMH
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
M-506
GDSMH
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
MECHANICAL
DETAILS
M-507
ARFMH
M A
T C
H L
IN
E
S E
E D
W G
M P
F O
R C
O N
T
IN
U A
T
IO
N
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
MECHANICAL STEAM GENERATION
FLOW DIAGRAM - BOILERS
MP601
GDSMH
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
M A
T C
H L
IN
E
S E
E D
W G
M P
F O
R C
O N
T
IN
U A
T
IO
N
File details come from the government source that posted it. Updated .