589A7-18-302 Wichita Bid Drawings - 2_Civil (SI) 2 of 3.pdf
PDF 8 MB Posted
- Solicitation number
- 36C25522R0079
About this file
This document package includes civil site utility drawings for a federal construction project to install new boilers in Building 13 at the Robert J. Dole VA Medical Center in Wichita, Kansas. The drawings show plans for site work including utility lines for water, sanitary sewer, storm drainage, and rain leaders. Details include pipe locations, sizes, cleanouts, manholes, and connections to existing infrastructure. Sheet notes provide installation specifications. The involved federal agency is the Department of Veterans Affairs and the solicitation number is 36C25522R0079.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X X
X X
X
X X
X X
X
X
X X
X X
X X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
IRP
1349.24
IRP
IRP
1349.64
IRP
ELX
1349.16
ELX
1347.96
LP
1349.90
LP
LP
1349.76
LP
LP
1348.20
LP
1350.55
LP
1353.25
LP
1347.29
LP
1351.68
LP
EM
1349.49
EM
LP
1349.57
LP
BOR P-1
1350.82
BOR P-1
BOR B-2
1350.16
BOR B-2
BOR P-2
1350.78
BOR P-2
X
XXX
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
WOOD FENCE
WOOD FENCE
CH
AI
N
LIN
K
FE
NC
E
CH
AI
N
LIN
K
FE
NC
E
CITY R.O.W.
> LP
1353.25
LP
X X
X
X
X X
X X
X
NEW BUILDING ADDITION
E. WATERMAN STREET
S.
E
D G
EM
O
O R
D R
IV
E
15.24m M
in. Standoff
DN
161110
411.46
411.76
411.46
411.46
INSTALL SILT FENCE
INSTALL SILT FENCE
INSTALL INLET PROTECTION
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
VA FORM 08-6231
NORTH
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Se rv ic e
D i s ab l ed
Vet eran Owned Sma l l Business
SDVOSB
CVE
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
1320 12
34, 34A
1B
2A
5B
1A
35A
7A
1C
5A
3A
KEYPLAN
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
DRC SMT / DSB
CG102.01
CIVIL SITE
EROSION CONTROL PLAN, PHASE 1
0 6.10m 12.20m3.05m
EROSION CONTROL LEGEND
PROPOSED SILT FENCE
PROPOSED INLET PROTECTION
EROSION CONTROL NOTES:
1. THE CONTRACTOR SHALL PREPARE AND SUBMIT
A STORM WATER POLLUTION PREVENTION PLAN
(SWPPP) IN ACCORDANCE WITH KDPHE
REQUIREMENTS TO THE V.A. FOR APPROVAL
PRIOR TO START OF CONSTRUCTION.
2. THE CONTRACTOR SHALL INSTALL ANY
ADDITIONAL EROSION AND SEDIMENT CONTROL
MEASURES AS NEEDED TO PREVENT SEDIMENT
TRANSPORT INTO STORM SEWERS, GUTTERS, OR
OFF-SITE DURING CONSTRUCTION.
3. SEE SHEET C-001 FOR ADDITIONAL EROSION
CONTROL AND SEEDING NOTES.
09/03/2021
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
VA FORM 08-6231
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Se rv ic e
D i s ab l ed
Vet eran Owned Sma l l Business
SDVOSB
CVE
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
DRC SMT / DSB
CG501
CIVIL SITE
BACK OF CURB PROTECTION AND
CONSTRUCTION ENTRANCE
NO. DESCRIPTION DATE
VA FORM 08-6231
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Se rv ic e
D i s ab l ed
Vet eran Owned Sma l l Business
SDVOSB
CVE
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
DRC SMT / DSB
CG502
CIVIL SITE
SLIT FENCE DITCH CHECK AND BARRIER
DETAILS
NO. DESCRIPTION DATE
VA FORM 08-6231
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Se rv ic e
D i s ab l ed
Vet eran Owned Sma l l Business
SDVOSB
CVE
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
DRC SMT / DSB
CG503
CIVIL SITE
STRAW BALE DITCH CHECK AND BARRIER
NO. DESCRIPTION DATE
VA FORM 08-6231
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Se rv ic e
D i s ab l ed
Vet eran Owned Sma l l Business
SDVOSB
CVE
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
DRC SMT / DSB
CG504
CIVIL SITE
STREET IMPROVEMENT PROJECTS DETAILS
NO. DESCRIPTION DATE
VA FORM 08-6231
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Se rv ic e
D i s ab l ed
Vet eran Owned Sma l l Business
SDVOSB
CVE
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
DRC SMT / DSB
CG505
CIVIL SITE
SUBDIVISION DEVELOPMENT PROCESS
U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E
U E
U E
U E
G G
G G
G G
G G
G G
G G
G G
G G
G
GG
G G
G G
G G
G G
G G
X X
X X
X
X X
X X
>O E O E
X
X
X X
X X
X X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
O E O E O E O E O E O E O E O E O E
O E O E
O E O E
O E O E
O E O E
O E
CP120
1347.85
CP 120
CP121
1349.38
CP 121
CP122
1349.22
CP 122
BM220
1348.40
BM 220
BM223
1349.91
BM 223
BM225
1352.57
BM 225
IRP
1349.24
IRP
IRP
1349.64
IRP
CP605
1346.53
CP MARKER
CP606
1346.61
CP MARKER
CP650
1355.63
CP 60D
CP651
1350.48
CP MAG
CP652
1350.61
CP MAG
CP653
1349.45
CP 60D
ELX
1349.16
ELX
ELR
1350.45
ELR
GV
1349.48
GV
GTV
1348.15
GTV
1347.96
WV
1348.28
WV
LP
1349.90
LP
LP
1349.76
LP
LP
1348.20
LP
WV
1348.50
WV
E
WV
1346.60
WV
GP
1348.71
GP
GP
1348.86
GP
GP
1349.92
GP
GP
1350.10
GP
GP
1350.80
GP
GP
1351.07
GP
H
WV (PIV)
1349.74
WV (PIV)
WV
1345.75
WV
WV
1349.30
WV
WV
1349.26
WV
WV
1349.22
WVWV
1349.14
WV
E
1350.55
WV
1346.62
WV
1346.32
ELR
1346.57
ELR
ELR
1346.52
ELR
E
WV (PIV)
1350.40
WV (PIV)
LP
1353.25
LP
GP
1353.61
GP
WV (TN=1346.08)
WV (TN=1347.16)
WV (TN=1347.25)
1349.80
WV (TN=1347.25)
WV (TN=1347.68)
WV (PIV)
1350.18
WV (PIV)
WV (TN=1347.83)
1350.88
WV (TN=1347.83)
WV (TN=1347.70)
1347.29
DDM 0
1351.79
DDM 0
LP
1351.68
LP
EM
1349.49
EM
LP
1349.57
LP
1349.12
ELR
1348.95
ELR
BOR P-1
1350.82
BOR P-1
BOR B-2
1350.16
BOR B-2
BOR P-2
1350.78
BOR P-2
WV
1348.55
WV
WV
1348.54
WV
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
G
G
G
G
G
G G
G G
G G
G G
G
U E U E U E U E
G G G G G G G G G G G G G
G G
G
G G G G G G
W W
W W
W W
W W W U
E
U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E
U E
U E
U E
U E
UT
U E
UT
UT
UT
UT
U E
U E
U E
U E U E
U E
U E U E
U E
U E
U E U E
U E
U E
U E U E
UT UT UT
UT
UT
U E U E
U E U E
U E
UT
UT
UT UT UT UT UT
UT
UT
UT
UT UT
U E
U E
U E
U E
W W
W
W
UT
U E U E
CONTROL BOX
ELR
1351.21
ELR
ELR
1351.36
ELR
ELR
1350.05
ELR
ELR
1350.27
ELR
ELR
1351.42
ELR
ELR
ELR
1346.98
ELRELR
1346.58
ELR
TR
1346.87
TR
E
ELR (5)
1346.76
ELR (5)
ELR
1346.95
ELR
ELR
1347.38
ELR
1348.62
ELR
1349.91
ELR
ELR
1350.83
ELR
ELR
1350.53
ELR
ELR
1346.64
ELR
ELR
1346.62
ELR
ELR
1345.44
ELR
ELR
1348.73
ELR
ELR
1347.17
ELR
O E O E O E O E O E O E O E O E O E
X
XXX
UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT
W
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
G G G G G G G G G G G G G G
WOOD FENCE
WOOD FENCE
CH
AI
N
LIN
K
FE
NC
E
CH
AI
N
LIN
K
FE
NC
E
U E U E
U E
W
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
U E W W W
W
W
W W
W W
W W
W W
W
W
W
6" (RECORD SIZE)
W W W W W W W W
W W
W W
W W
W W
W
W
4" SOFT WATER (REC. SIZE & LOC.)
4" (REC. SIZE & LOC.)
4" SOFT WATER (REC. SIZE & LOC.)
6" (REC. SIZE)
8" (REC. SIZE)
8" (R
EC
. S
IZ
E
LO
C.
4" (REC. SIZE & LOC.))
8" (
REC. S
IZE & LO
C.)
8" (REC. SIZE & LOC.)
6" (REC. SIZE)
4" S
OF
T
W
AT
ER
(R
EC
. S
IZ
E
LO
C.
W W W W W W W W W W W W W W W W W W W W
W W
W W
W
W
W
W W
W
W W
4" (REC. SIZE & LOC.)
4" (REC. SIZE & LOC.)
8" (REC. SIZE & LOC.)
6" (REC. SIZE & LOC.) 8" (REC. SIZE & LOC.)
8" (R
EC
. S
IZ
E
LO
C.
8" (REC. SIZE & LOC.)
8" (REC. SIZE & LOC.)
W W W W W W W W
W W
W
U E
U E
U E
U E
U E
U E
U E
U E
CITY R.O.W.
O E O E O E O E O E O E O E O E O E
CP654
1355.63
CP 60D
LP
1353.25
LP
GP
1353.61
GP
E
E
E
ELR
1355.69
ELR
ELR
1355.86
ELR
GP
1354.23
GP
GP
1354.73
GP
E
X X
X
X
X X
X X
X X
X
U E
U E U E
U E U E
U E
U E U E U E U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E U E
UT
UT
UT
UT
UT UT
U E
U E U E U E U E U E U E U E
DUCT BANKU E
U E
U E U E U E
U E
U E
U E
15.24m M
in. Standoff
DN
W W
W W
W
W W W W W W W W W W W W W W
W W
G G
G G G
W
W
W
W W W
W
F F
F
W W
W
W
W
W
W W
G
G G G G G G G G G G
G
G
G G G G G G G G G G G
G
G
NEW RELOCATED 200mm WATERLINE.
SEE SHEET CU221.01.
NEW WATER TANK.
APPROX. 300,000 LITERS
NEW PRECAST STEAM PIPE
TRENCH AND CONDENSATE LINE.
SEE MECHANICAL PLANS.
EXISTING
WEST TANK
EXISTING
EAST TANK
TEMPORARY 100mm GAS SERVICE LINE.**
TEMPORARY 75mm DOMESTIC
SERVICE LINE.**
NEW ELECTRIC
NEW BUILDING ADDITION
NEW 75mm WATER SERVICE, SEE SHEET CU201.01.
NEW STEAM MANHOLE.
SEE MECHANICAL PLANS.
NEW RELOCATED SWS LINE (TYP.).
SEE SHEET CU301.01.
NEW ELECTRIC FEEDER
FROM SWITCH TO BUILDING 13
ADDITION TRANSFORMER.
NEW RAIN LEADER, SEE
SHEET CU301.01.
RELOCATED GENERATOR
RECONNECT EXISTING
FEEDS AS NEEDED. SEE
ELECTRICAL PLANS.
NEW ROUTE ELECTRIC
SERVICE TO GATE ARMS.
SEE ELECTRICAL PLANS.
161110
9.14m DIA.
INSTALL 14.6m OF 150mm PVC SANITARY
SEWER SERVICE @ 1.0% MIN. SLOPE.
SEE PLUMBING PLANS FOR CONTINUATION.
NEW 150mm FIRE SERVICE LINE, SEE SHEET CU223.01.
TEMPORARY 75mm
DOMESTIC SERVICE &
VALVE.**
SEE MECH. PLANS
TEMPORARY 100mm
GAS SERVICE AND
VALVE.**
INSTALL TRENCH DRAINS
(TYP.). SEE SHEET CU301.01.
NEW 150mm GAS SERVICE
LINE FROM BLDG. 17.
NEW FIRE HYDRANT
NEW 100mm WATER SERVICE
TO TANK
SEE MECHANICAL PLANS
FOR GAS SERVICE
CONNECTION.
SEE MECHANICAL PLANS
FOR GAS SERVICE
CONNECTION.
INSTALL 25.2m (TOTAL) 100mm PVC SANITARY
SEWER SERVICE @ 2.0% MIN. SLOPE. ENTIRE
LENGTH TO BE ENCASED IN CONCRETE. SEE
PLUMBING PLANS FOR CONTINUATION. N: 1684511.8317, E: 1667611.8461
NEW 150mm SANITARY SEWER CONNECTION TO 200mm MAIN. *
FL=409.13
N: 1684511.3793, E: 1667581.8815 NEW 2.25m OF 100mm PVC SANITARY
SEWER SERVICE @ 2% MIN SLOPE.
SEE PLUMBING PLANS FOR
CONTINUATION.
CONNECT TO EX. 200mm MAIN FL=409.10 *
N: 1684510.1821, E: 1667500.9160 NEW 100mm SANITARY SEWER
CONNECTION TO 200mm MAIN. *
FL=409.02
N: 1684573.6542; E: 1667500.9204 1- 45° 100mm BEND & CLEANOUT
FL=409.48
N: 1684584.5267; E: 1667511.7929 1- 45° 100mm BEND
FL=410.70
N: 1684584.5267 E: 1667513.5513
INSTALL SANITARY CLEANOUT
N: 1684517.0948 E: 1667581.8090
INSTALL SANITARY
CLEANOUT
N: 1684557.8827 E: 1667610.8514
INSTALL SANITARY
CLEANOUT
NEW SUMP PUMP DRAIN LINE.
SEE SHEET CU302.01.
NEW SUMP PUMP DRAIN LINE.
SEE SHEET CU302.01.
NEW SUMP PUMP DRAIN LINE.
SEE SHEET CU302.01.
CAUTION!!
PROP. ELECTRIC
CAUTION!!
PROP. ELECTRIC
CAUTION!!
PROP. WATERLINE
CAUTION!!
PROP. UTILITIES
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
VA FORM 08-6231
NORTH
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Se rv ic e
D i s ab l ed
Vet eran Owned Sma l l Business
SDVOSB
CVE
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
1320 12
34, 34A
1B
2A
5B
1A
35A
7A
1C
5A
3A
KEYPLAN
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
DRC SMT / DSB
0 6.10m 12.20m
CU101.01
CIVIL SITE
UTILITY PLAN, PHASE 1
PROPOSED SANITARY SEWER
PROPOSED SANITARY SEWER CLEANOUT
UTILITY LEGEND
PROPOSED STORM SEWER
PROPOSED STORM SEWER MANHOLE
PROPOSED WATERLINEW W
PROPOSED UNDERGROUND ELECTRIC
PROPOSED UNDERGROUND TELECOM/CABLEUT UT
GENERAL NOTES
1. SEE ELECTRICAL SITE PLAN FOR
ADDITIONAL UG ELECTRIC AND TELECOM
INFORMATION. COORDINATE ALL WORK
WITH ELECTRICAL PLANS.
* PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR
SHALL EXCAVATE THE EXISTING 200mm SANITARY SEWER
PIPE AT TIE-IN LOCATION TO VERIFY ITS HORIZONTAL AND
VERTICAL LOCATION. THE PIPE LOCATION SHALL BE
REPORTED TO THE ENGINEER SO THAT ANY NECESSARY
PLAN MODIFICATIONS CAN BE MADE. ANY ADDITIONAL LABOR
OR MATERIALS NECESSARY TO COMPLETE THE CONNECTION
SHALL BE CONSIDERED SUBSIDIARY TO THE PROJECT.
** REMOVE TEMPORARY SERVICES PRIOR TO CONSTRUCTION
OF ADA RAMP
3.05m
PROPOSED GAS SERVICE LINEG G
U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E
X X
X X
X X
X X
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
O E
O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E
CP651
1350.48
CP MAG
15" CEDAR
15" CEDAR15" CEDAR15" CEDAR
15" CEDAR
WV (PIV)
1350.40
WV (PIV)
NO PARKING
WV (TN=1346.08)
WV (TN=1347.16)
WV (TN=1347.25)
1349.80
WV (TN=1347.25)
WV (TN=1347.68)
DDM 0
1351.79
DDM 0
LP
1351.68
LP
BOR P-1
1350.82
BOR P-1
BOR B-2
1350.16
BOR B-2
BOR P-2
1350.78
BOR P-2
U E U E U E U E
W
W W W W
U E
U E
U E
ELR
1351.42
ELR
ELR
TR
1346.87
TR
ELR
1349.91
ELR
ELR
1350.83
ELR
ELR
1350.53
ELR
O E O E
G G G G G G G G G G G G
WOOD FENCE
U E U E U E U E U E
W
W W
UT
UT
UT
UT
UT
UT
W W W W W W W W
W W
4" SOFT WATER (REC. SIZE & LOC.)
4" SOFT WATER (REC. SIZE & LOC.)
6" (REC. SIZE)
W W W W W W
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
15.24m M
in. Standoff
DN
W W
W W
W W
W W
W W
W
W W W W W W W W W W W W W W W W W W W W W W W W W W W W
W W
W W
G G
G G
G G G G G G
W
W
W
W
W
W
W W W W W W W
W W
W
W
F F
F F
F F
F
W
W W
W W
W W
W
W
W
W W
W
W
W
W
W
W W
W W
W
G G
G
G G G G G G G G G G G G G G G G G G G G
G
G
G
G
G
G G G G G G G
W
EXISTING WEST
TANK
EXISTING EAST
TANK
NEW BUILDING ADDITION
APPROX. 300,000 LITER
WATER STORAGE
NEW 200mm WATERLINE, SEE SHEET CU221.01.
INSTALL 14.52m 75mm DOMESTIC SERVICE LINE.
NOTE: SEE PLUMBING PLANS
FOR STORAGE TANK PIPING
INFORMATION AND DETAILS
INSTALL 6.70m 100mm PVC
INSTALL 9.05m 100mm PVC
INSTALL 10.06m 100mm PVC
INSTALL 3.18m 100mm PVC
CAUTION!!
PROP. ELECTRIC
NEW 150mm FIRE SERVICE
LINE, SEE SHEET CU223.01.
N: 1,684,606.9207, E: 1,667,579.3768 75mm DOMESTIC SERVICE LINE.
SEE PLUMBING PLANS FOR CONTINUATION.
N: 1,684,652.1620, E: 1,667,476.2057 CONNECT 75mm DOMESTIC SERVICE LINE TO NEW 200mm WATERLINE.
1 - 200mm x 100mm TEE 1 - 100mm VALVE (S)
N: 1,684,653.5694, E: 1,667,578.7269 75mm DOMESTIC SERVICE TAP AND VALVE CONN. TO NEW 200mm WATERLINE.
N: 1,684,641.2243, E: 1,667,476.3559 REFERENCE PLUMBING PLANS FOR 100mm
WATERLINE CONTINUATION.
N: 1,684,612.5387, E: 1,667,466.9865 CONNECT 100mm WATERLINE TO STORAGE
TANK. REFERENCE PLUMBING PLANS.
N: 1,684,575.7242, E: 1,667,481.7839 1 - 100mm 45° BEND
N: 1,684,552.3752, E: 1,667,505.1330 1 - 100mm 45° BEND
N: 1,684,522.6412, E: 1,667,505.6615 1 - 100mm 90° BEND
N: 1,684,522.8266, E: 1,667,516.0922 100mm TANK WATER SERVICE WITH VALVE.
SEE PLUMBING PLANS FOR CONTINUATION.
CAUTION!!
PROP. ELECTRIC
NEW STORM SEWER LINE,
SEE SHEET CU321.01.
NEW 200mm WATERLINE, SEE SHEET CU221.01.
CAUTION!!
PROP. ELECTRIC
CAUTION!!
PROP. STEAM TRENCH. LOWER LINE
AS NEEDED FOR INSTALLATION.
CAUTION!!
PROP. RAIN LEADER
CAUTION!!
PROP. STORM SEWER
CAUTION!!
EXIST. STORM SEWER. INSTALL
100mm WATER LINE BELOW EX.
STORM.
INSTALL 21.73m (TOTAL) 75mm
DOMESTIC SERVICE LINE
N: 1,684,581.5315, E: 1,667,644.3181 CAP 100mm LINE.
N: 1,684,569.1750, E: 1,667,644.7737 75mm TAP TO EXISTING 200mm LINE. CAP
WHEN TEMPORARY LINE IS REMOVED.
N: 1,684,548.2036, E: 1,667,645.3543 1 - 75mm 90° BEND
N: 1,684,547.6595, E: 1,667,595.0243 75mm TEMP. DOMESTIC SERVICE LINE WITH VALVE.
SEE PLUMBING PLANS FOR CONTINUATION.
CAUTION!!
PROP. ELECTRIC
CAUTION!!
PROP. ELECTRIC
HOT BOX FOR RPZ.
SEE PLUMBING PLANS.
N: 1,684,597.6903, E: 1,667,481.7538 1 - 100mm 45° BEND
INSTALL 6.38m 100mm PVC
CAUTION!!
PROP. ELECTRIC
CAUTION!!
EX. ELECTRIC
CAUTION!!
EX. STEAM TRENCH. LOWER LINE
AS NEEDED FOR INSTALLATION.
CAUTION!!
PROP. GAS LINE
CAUTION!!
PROP. GAS LINE
N: 1,684,622.4453, E: 1,667,672.7655
NEW FIRE HYDRANT ASSEMBLY
INSTALL 3.32m 150mm PIPE
CAUTION!!
PROP. SANITARY SEWER
CAUTION!!
EX. STORM LINE
CAUTION!!
PROP. SANITARY SEWER
CAUTION!!
PROP. SUMP PUMP
DRAIN LINE
CAUTION!!
PROP. ELECTRIC
CAUTION!!
PROP. ELECTRIC
CAUTION!!
PROP. SUMP PUMP
DRAIN LINE
W W
W W
W W
W
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
VA FORM 08-6231
NORTH
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Se rv ic e
D i s ab l ed
Vet eran Owned Sma l l Business
SDVOSB
CVE
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
1320 12
34, 34A
1B
2A
5B
1A
35A
7A
1C
5A
3A
KEYPLAN
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
DRC SMT / DSB
0 3.05m 6.10m
CU201.01
CIVIL SITE
OVERALL WATER PLAN, PHASE 1
UTILITY LEGEND
PROPOSED STORM SEWER
PROPOSED STORM SEWER MANHOLE
PROPOSED WATERLINEW W
PROPOSED UNDERGROUND ELECTRIC
PROPOSED UNDERGROUND TELECOM/CABLEUT UT
* PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR
SHALL EXCAVATE THE EXISTING 200mm PVC PIPE AT
WATERLINE NO. 1 STATIONS 00+00.00 AND 3+17.09 TO VERIFY
ITS HORIZONTAL AND VERTICAL LOCATION. THE PIPE
LOCATION SHALL BE REPORTED TO THE ENGINEER SO THAT
ANY NECESSARY PLAN MODIFICATIONS CAN BE MADE. ANY
ADDITIONAL LABOR OR MATERIALS NECESSARY TO
COMPLETE THE CONNECTION SHALL BE CONSIDERED
SUBSIDIARY TO THE PROJECT.
PROPOSED FIRE LINEF F
PROPOSED GAS SERVICE LINEG G
U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E
X X
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
O E
O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E
CP651
1350.48
CP MAG
15" CEDAR
15" CEDAR15" CEDAR15" CEDAR
15" CEDAR
6" BUSH
CO
1346.26
CO
CO
1348.10
CO
RD
MB
1348.77
MB
RD RD
6 STEPS
FUEL LID
LID
LID
DRAIN
4" VENT
VENT PIPE
RD
CO
1346.91
CO
7 STEPS
RD
RD
44" LID
WV (PIV)
1350.40
WV (PIV)
RD
A/C UNIT
1350.55
NO PARKING
PIPE SUPPORT
PIPE SUPPORT
WV (TN=1346.08)
WV (TN=1347.16)
WV (TN=1347.25)
1349.80
WV (TN=1347.25)
WV (TN=1347.68)
RD
DDM 0
1351.79
DDM 0
LP
1351.68
LP
BOR P-1
1350.82
BOR P-1
BOR B-2
1350.16
BOR B-2
BOR P-2
1350.78
BOR P-2
U E
W
W
U E
U E
U E
ELR
1351.42
ELR
ELR
TR
1346.87
TR
ELR
1349.91
ELR
ELR
1350.83
ELR
ELR
1350.53
ELR
TANK NOT FOUND
O E O E O E O E
G G G G G G G G G G G G G G G
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
GRAVEL SIDEWALK
GRATE
GRATE
GRATE
GRATE
U E U E U E U E U E
SSM-28
SSM-25
SDM-16
SDM-5500
SDM-15
SDA-7
SDA-6
SDA-5
SDA-3
SDA-14SDA-4
SDA-27
" R
C P
" R
C P
24" RCP
6" CIP30" RCP
" R
CP
6" (T
YP
E
U N
KN
O
W N
6" C
IP
6" CIP
6" C
IP
8" VCP
8" C
IPTANK OUTER WALL TANK OUTER WALL
W
W W
GRAVEL
GRAVEL
GRASS
GRASS
CONCRETE
GRASS
GRASS
GRASS
GRASS
ASPHALT
CONCRETE
ASPHALT
ASPHALT
CONCRETE
HANDRAIL
HANDRAIL
LID
LID
MANHOLE
STEAM LINE
UT
UT
UT
UT
UT
UT
6" (RECORD SIZE)
W W W W W W W W W W
W W
4" SOFT WATER (REC. SIZE & LOC.)
4" SOFT WATER (REC. SIZE & LOC.)
W W W W W W W W
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
4" CIP (RECORD)
15.24m M
in. Standoff
DN
W W
W W
W W
W W
W W
W
W W W W W W W W W W W W W W W W W W W W W W W W W W W W
W W
W W
G G
G G
G G G G G G
W
W
W
W
W
W
W W W W W W W
W W
W
W
F F
F F
F F
F
W
W W
W W
W W
W
W
W
W W
W
W
W
W
W
W W
W W
W
G G
G
G G G G G G G G G G G G G G G G G G G G
G
G
G
G
G
G G G G G G G G G G
W
EXISTING WEST
TANK
EXISTING EAST
TANK
NEW BUILDING ADDITION
N: 1,684,552.8023, E: 1,667,639.5037
INSTALL CATCH BASIN
ON EX. 150mm STORM LINE * 300mm NYLOPLAST DRAIN BASIN
(OR EQUAL) W/ TRAFFIC RATED COVER
TOP=410.66
FL=409.02
INSTALL 9.1m 150mm 6" PVC
CONNECT TO EXISTING
BUILDING 13 RAIN LEADER. *
EXTEND 100mm RAIN
LEADER FROM BUILDING
12 *
INSTALL CAST IRON
DOWNSPOUT BOOT WITH
CLEANOUT TO 150mm PVC R.L.
FL=410.88
(TYP. AT EACH DOWNSPOUT)
INSTALL 15.3m 200mm PVC R.L.
150mm PVC RAIN LEADER @ 1%
(TYP. AT EACH DOWNSPOUT)
INSTALL 13.0m 200mm PVC R.L.
INSTALL 4.9m 150mm 6" PVC
N: 1,684,552.2776, E: 1,667,609.7688 CONSTRUCT 150mm CLEANOUT
TOP=410.91
FL=409.84
INSTALL 4.0m 150mm PVC
N: 1,684,565.5518, E: 1,667,637.1908
INSTALL CATCH BASIN
300mm NYLOPLAST DRAIN BASIN
(OR EQUAL) W/ TRAFFIC RATED COVER
TOP=411.25
FL=409.26
INSTALL 9.5m 150mm PVC
FROM SUMP PUMP. REF PLUMBING
PLANS FOR CONTINUATION IN BLDG.
3.00'
NEW RELOCATED 200mm WATERLINE.
SEE SHEET CU221.01.
NEW WATER SERVICE, SEE
SHEET CU201.01. NEW RELOCATED SWS LINE (TYP.).
SEE SHEET CU301.01.
NEW 150mm FIRE SERVICE LINE, SEE SHEET CU223.01.
NEW PRECAST STEAM PIPE
TRENCH AND CONDENSATE LINE.
SEE MECHANICAL PLANS.
INSTALL TRENCH DRAINS. ACO S100K OR
APPROVED EQUAL. PROVIDE ALL
REQUIRED ADAPTORS AND FITTINGS.
(TYP.) COORDINATE INSTALLATION WITH
SECURITY BOLLARD FOUNDATIONS.
INSTALL 8.5m 200mm PVC R.L. @ 1%
CONNECT 200mm PVC R.L. TO INLET.
FL = 409.63
SEE SHEET CU321.01.
CONNECT 150mm PVC FROM
SUMP PUMP TO INLET.
FL=409.33
SEE SHEET CU321.01.
1.22m 3.35m 3.35m 3.35m 1.22m 3.69m 2.13m
CAUTION!
NEW STEAM TRENCH. ROUTE PVC
PIPES BELOW TRENCH AS NEEDED.
CAUTION!
150mm GAS LINE
N: 1,684,609.1963 E: 1,667,527.3785
INSTALL 150mm CLEANOUT W/
TRAFFIC RATED LID.
FL=410.85
N: 1,684,609.7944 E: 1,667,570.3479
INSTALL CLEANOUT.
FL IN=410.70
FL OUT=409.72
N: 1,684,610.4819 E: 1,667,620.0121 INSTALL 150mm CLEANOUT W/
TRAFFIC RATED LID.
FL=410.85
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
VA FORM 08-6231
NORTH
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Se rv ic e
D i s ab l ed
Vet eran Owned Sma l l Business
SDVOSB
CVE
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
1320 12
34, 34A
1B
2A
5B
1A
35A
7A
1C
5A
3A
KEYPLAN
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
DRC SMT / DSB
0 3.05m 6.10m
CU301.01
CIVIL SITE
RAIN LEADER PLAN, PHASE 1
PROPOSED SANITARY SEWER
PROPOSED SANITARY SEWER MANHOLE
PROPOSED SANITARY SEWER CLEANOUT
UTILITY LEGEND
PROPOSED STORM SEWER
PROPOSED STORM SEWER MANHOLE
PROPOSED WATERLINEW W
PROPOSED UNDERGROUND ELECTRIC
1. CONTRACTOR TO INCLUDE ALL PIPE, FITTINGS, LABOR IN BID
PRICE. THE SIZES SHALL BE AS SHOWN ON THE UTILITY PLAN.
2. MINIMUM SLOPE FOR ALL PIPING SHALL BE 1.0%, UNLESS
OTHERWISE NOTED.
3. CLEAN-OUT TOP ELEVATION SHALL MATCH FINAL GRADES.
4. ALL RAIN LEADER PIPING 150mm OR LESS SHALL BE SCH 40 PVC.
ALL RAIN LEADER PIPING 200mm SHALL BE SDR 35 PVC.
RAIN LEADER NOTES:
* PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR
SHALL EXCAVATE THE EXISTING PIPE TO VERIFY ITS
HORIZONTAL AND VERTICAL LOCATION. THE PIPE LOCATION
SHALL BE REPORTED TO THE ENGINEER SO THAT ANY
NECESSARY PLAN MODIFICATIONS CAN BE MADE. ANY
ADDITIONAL LABOR OR MATERIALS NECESSARY TO
COMPLETE THE CONNECTION SHALL BE CONSIDERED
SUBSIDIARY TO THE PROJECT.
U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E
>O E O E
X
X
X X
X X
X X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
O E O E O E O E O E O E O E O E O E
BM225
1352.57
BM 225
CP606
1346.61
CP MARKER
CP650
1355.63
CP 60D
CP651
1350.48
CP MAG
15" CEDAR15" CEDAR15" CEDAR15" CEDAR
15" CEDAR
INFO
CO
1346.26
CO
CO
1348.10
CORD
MB
1348.77
MB
RD
RD RD
6 STEPS
FUEL LID
LID
LID
DRAIN
4" VENT
VENT PIPE
RDCO
1346.91
CO 7 STEPS
RD
RD
6 STEPS
RD
6 STEPS
44" LID
VAULT ACCESS
A/C UNIT
RD
WV (PIV)
1350.40
WV (PIV)
RD
A/C UNIT
1350.55
NO PARKING
STOP
STOP
LP
1353.25
LP
GP
1353.61
GP LP
1353.44
LP
PIPE SUPPORT
PIPE SUPPORT
WV (TN=1346.08)
WV (TN=1347.16)
WV (TN=1347.25)
1349.80
WV (TN=1347.25)
WV (TN=1347.68)
RD WV (PIV)
1350.18
WV (PIV)
WV (TN=1347.70)
DDM 0
1351.79
DDM 0
LP
1351.68
LP
BOR P-1
1350.82
BOR P-1
BOR B-2
1350.16
BOR B-2
BOR P-2
1350.78
BOR P-2
U E
U E
U E
U E
U E
U E
U E U E U E U E
W W
W W
W
W W W
U
E ELR
1350.05
ELR
ELR
1351.42
ELR
ELR
TR
1346.87
TR
ELR
1349.91
ELR
ELR
1350.83
ELR
ELR
1350.53
ELR
TANK NOT FOUND
ELR
1347.17
ELR
O E O E O E O E O E O E
G G G G G G G G G G G G
4' STEAM TUNNEL
4' STEAM TUNNEL
VAULT
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
GRAVEL SIDEWALK
GRATE
GRATE
GRATE
WOOD FENCE
WOOD FENCE
U E U E
SSM-28
SSM-25
SDM-16
SDM-5500
SDA-30
SDM-15
SDA-6
SDA-5
SDA-3
SDA-27
30" RCP
" R
C P
" R
C P
24" RCP
6" CIP30" RCP
" R
CP
6" (T
YP
E
U N
KN
O
W N
6" C
IP
6" CIP
6" C
IP
8" VCP
8" C
IPTANK OUTER WALL TANK OUTER WALL
W
GRAVEL
GRAVEL
GRASS
GRASS
GRASS
GRASS
CONCRETE
CONCRETE
CONCRETE
GRAVEL
GRAVEL
GRASS
GRASS
GRASS
GRASS
ASPHALT
CONCRETE
ASPHALT ASPHALT ASPHALT
CONCRETE
HANDRAIL
HANDRAIL
LID
LID
MANHOLE
STEAM LINE
UT
UT
UT
W
6" (RECORD SIZE)
W W W W W W W W
W
W
4" SOFT WATER (REC. SIZE & LOC.)
4" (REC. SIZE & LOC.)
4" SOFT WATER (REC. SIZE & LOC.)
6" (REC. SIZE)
W W W W W W W
U E
U E
U E
U E
U E
U E
U E
4" CIP (RECORD)
O E O E O E O E O E O E O E O E O E O E
CP654
1355.63
CP 60D
VAULT ACCESS
LP
1353.25
LP
GP
1353.61
GP
LP
1353.44
LP
NO PARKINGGP
1355.18
GP
E
E
E SPEED LIMIT 15
ELR
1355.69
ELR
ELR
1355.86
ELR
HOSPITAL
GP
1354.23
GP
GP
1354.73
GP
7" ELM
LP
1358.24
LP
EM
1356.92
EM
ELR (TYP. OF 4)
E
X
X X
X X
X
X
X X
X X
X X
XXXX
U E
U E U E
U E U E
U E
U E U E U E U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E U E
UT
UT
UT
UT
UT UT
U E U E
U E
U E U E
U E U E U E U E U E U E U E U E
DUCT BANKU E
U E
U E U E U E
U E
U E
U E
15.24m M
in. Standoff
DN
W W
W W
W
W W W W W W W W W W W W W W
W W
G G
G G G
W
W
W
W W W
W
F F
F
W W
W
W
W
W
W W
G
G G G G G G G G G G
G
G
G G G G G G G G G G
EXISTING
WEST TANK
EXISTING
EAST TANK
NEW BUILDING ADDITION
INSTALL 25.6m 100mm PVC
NEW RELOCATED 200mm WATERLINE.
SEE SHEET CU221.01.
NEW WATER SERVICE, SEE
SHEET CU201.01.
NEW RELOCATED SWS LINE (TYP.).
SEE SHEET CU301.01.
NEW 6" FIRE SERVICE LINE,
SEE SHEET CU223.01.
N: 1,684,622.4974 E: 1,667,296.7772
CONNECT TO MANHOLE
SUMP PUMP OUTLET
INSTALL 100mm CLEANOUT
FL=411.46
N: 1,684,623.2286 E: 1,667,380.8296
INSTALL 100mm 45° BEND
WITH CLEANOUT
FL=411.46
REMOVE AND REPLACE PAVEMENT
AS NEEDED FOR PIPE INSTALLATION
NEW PRECAST STEAM TRENCH.
SEE MECHANICAL PLANS.
NEW RAIN LEADER.
SEE SHEET CU301.01.
N: 1,684,663.1452 E: 1,667,420.3198
INSTALL 100mm 45° BEND
WITH CLEANOUT
FL=411.05
N: 1,684,661.7863 E: 1,667,498.2276
INSTALL 2 - 100mm 45° BENDS
WITH CLEANOUT
FL=409.45
N: 1,684,639.2407 E: 1,667,498.5258
INSTALL 2 - 100mm 45° BENDS 1 - 100mm 45° DOUBLE WYE
WITH CLEANOUT
FL=409.30
INSTALL 16.5m 100mm PVC
INSTALL 23.7m 100mm PVC
INSTALL 7.4m 100mm PVC
CONNECT TO MANHOLE
SEE SHEET CU321.01.
FL= 409.23
INSTALL 3.5m 100mm PVC
N: 1,684,583.9748 E: 1,667,497.2202
CONNECT TO MANHOLE
SUMP PUMP OUTLET
INSTALL 100mm CLEANOUT
FL=410.39
N: 1,684,657.4323 E: 1,667,640.2840
CONNECT TO MANHOLE
SUMP PUMP OUTLET
INSTALL 100mm CLEANOUT
FL=409.33
CONNECT TO MANHOLE
SEE SHEET CU321.01.
FL= 409.17
INSTALL 16.6m 100mm PVC
INSTALL 6.0m 100mm PVCCAUTION!
PROP. ELECTRIC
CAUTION!
EX. ELECTRIC
CAUTION!
PROP. WATERLINE
CAUTION!
PROP. ELECTRIC
CAUTION!
PROP. STEAM TUNNEL
CAUTION!
PROP. WATER LINE
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
VA FORM 08-6231
NORTH
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Se rv ic e
D i s ab l ed
Vet eran Owned Sma l l Business
SDVOSB
CVE
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
1320 12
34, 34A
1B
2A
5B
1A
35A
7A
1C
5A
3A
KEYPLAN
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
DRC SMT / DSB
0 6.10m 12.20m
CU302.01
CIVIL SITE
MANHOLE SUMP PUMP PIPING PLAN, PHASE 1
PROPOSED SANITARY SEWER
PROPOSED SANITARY SEWER MANHOLE
PROPOSED SANITARY SEWER CLEANOUT
UTILITY LEGEND
PROPOSED STORM SEWER
PROPOSED STORM SEWER MANHOLE
PROPOSED WATERLINEW W
PROPOSED UNDERGROUND ELECTRIC
1. CONTRACTOR TO INCLUDE ALL PIPE, FITTINGS, LABOR IN BID
PRICE. THE SIZES SHALL BE AS SHOWN ON THE UTILITY PLAN.
2. MINIMUM SLOPE FOR ALL PIPING SHALL BE 2.0%, UNLESS
OTHERWISE NOTED.
3. CLEAN-OUT TOP ELEVATION SHALL MATCH FINAL GRADES.
SUMP PUMP LINE NOTES:
150mm DIA. PLASTIC
ROOF DRAIN PIPE
150mm 45° PLASTIC BEND
200mm DIA. PLASTIC
STORM DRAIN PIPE
200mm X 150mm 45° PLASTIC WYE
PLAN
VARIES
75mm X 100mm DOWNSPOUT
CAST IRON DOWNSPOUT SHOE WITH CLEANOUT
(NEENAH R-4929-02C OR APPROVED EQUAL)
FINISHED GRADE
BUILDING WALL
FOOTING
0150mm DIA. PLASTIC
ROOF DRAIN PIPE
150mm 45 PLASTIC
BEND
200mm DIA. PLASTIC
STORM DRAIN PIPE
300mm X 150mm 45°
PLASTIC WYE
MANUFACTURER'S STANDARD
TRANSITIONAL COUPLING
100mm DIA. PLASTIC PIPE
100mm X 150mm PLASTIC ENLARGER
2 EACH 150mm 45° PLASTIC ELBOWS
1%
PROFILE
CAST IRON COVER AND
FRAME (NEENAH R-1791-C
OR APPROVED EQUAL
2 EACH 200mm 45°
PLASTIC BENDS
200mm DIA. PLASTIC
PIPE
150mm THICK (MIN.)
CONCRETE BASE
FINISHED GRADE
CLEANOUT
200mm X 150mm 45°
PLASTIC WYE
200mm DIA. PLASTIC
STORM DRAIN PIPE
FL
O
W
FLOW
200mm 45° PLASTIC
BEND
200mm DIA. PLASTIC
STORM DRAIN
PIPE
CLEANOUT
200mm X 150mm 45°
PLASTIC WYE
200mm DIA. PLASTIC
STORM DRAIN
PIPE
150mm DIA. PLASTIC
ROOF DRAIN
PIPE
150mm 45° PLASTIC
BEND
PLAN
PLAN
FL
O
W
FROM
BLDG
SECTION 1
NOTES:
1. STORM DRAIN CLEANOUTS SHALL BE INSTALLED AT THE END OF
STORM DRAIN LINES AND AT EACH 90 DEGREE TURN IN STORM
DRAIN LINES AS INDICATED.
MANUFACTURER'S STANDARD ADAPTOR AS REQUIRED
1 TYPICAL ROOF DRAIN DETAILS
NOT TO SCALE
2 STORM DRAIN CLEANOUT DETAILS
NOT TO SCALE
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
VA FORM 08-6231
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Se rv ic e
D i s ab l ed
Vet eran Owned Sma l l Business
SDVOSB
CVE
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
DRC SMT / DSB
CU501
CIVIL SITE
ROOF DRAIN DETAILS
1 CLASS A
NOT TO SCALE
2 CLASS B
NOT TO SCALE
3 CLASS C
NOT TO SCALE
4 PIPE ZONE BACKFILLING
NOT TO SCALE
5 TRENCH ZONE BACKFILLING
NOT TO SCALE
GRANULAR BEDDING MATERIAL OR SAND-GRAVEL BEDDING
GRANULAR BEDDING MATERIAL SHALL BE AN APPROVED MATERIAL CONSISTING OF
DURABLE CRUSHED ROCK CONFORMING WITH THE REQUIREMENTS OF THE LATEST
REVISION OF ASTM C-33 SIZE NO. 67 (3/4" TO NO. 4); TO BE PLACED IN NOT MORE
THAN 6" LAYERS AND COMPACTED BY SLICING WITH A SHOVEL OR VIBRATING.
SOUNDNESS, ABRASION, AND ABSORPTION LIMITS SHALL BE AS REQUIRED FOR
COARSE AGGREGATES IN 03 30 00 CAST-IN-PLACE CONCRETE IN THE
SPECIFICATIONS.
SAND-GRAVEL BEDDING MATERIAL - SAND-GRAVEL MIX MEETING TYPE UD-1 OF THE
2015 KANSAS STANDARD SPECIFICATIONS FOR STATE ROAD AND BRIDGE
CONSTRUCTION.
COMPACTED EMBEDMENT SHALL BE AN APPROVED SAND MATERIAL FREE FROM
DEBRIS, ORGANIC MATERIAL, AND STONES WITH 100% PASSING THE 3/4" SIEVE TO
BE PLACED IN UNIFORM LAYERS NOT MORE THAN 6" THICK AND COMPACTED TO 95
PERCENT MAXIMUM DENSITY AS DETERMINED BY ASTM D698. GRANULAR BEDDING
MATERIAL MAY BE SUBSTITUTED FOR ALL OR PART OF COMPACTED EMBEDMENT
MATERIALS.
UNCOMPACTED EARTH BACKFILL
COMPACTED EARTH BACKFILL
Bc = OUTSIDE PIPE DIAMETER
DEPTH OF BEDDING MATERIAL BELOW PIPE
D d (MIN) SOIL d (MIN) ROCK
700mm & SMALLER 100mm 150mm
750mm TO 1500mm 125mm 225mm
1650mm & LARGER 150mm 300mm
Bc + MIN.
1-1/4 Bc
Bc
1/
Bc
0m m
M
IN
1/4 D FOR D < 1.8m 150mm MIN. (TYP.)
#5 BARS (600mm CTRS.)
#5 BARS
Bc + (300mm TO 450mm)
TYPICAL
Bc
50mm CLR. (TYP.)
0m m M
IN
Bc1/
Bc d
0m m M
IN
Bc d
0m m M
IN
Bc d
0m m M
IN
Bc
1/
Bc d
Bc + (450mm)
VA
R
IE
S
0m mBc
Bc1/
Bc m m M
IN
U N
D
ER
B
AR
R
EL
CLASS A, B, OR C
BEDDING
600mm BELOW BOTTOM
OF PAVEMENT
FLOWABLE FILL
MATERIAL
Bc + (300mm TO 450mm)
TR
EN
C H
Z O
N E
0m m T
O m m
Bc
CLASS A, B, OR C
BEDDING
CLASS A, B, OR C
BEDDING
Bc
COMPACTED EMBEDMENT
CONCRETE
Bc = OUTSIDE PIPE DIAMETER
H = BACKFILL FROM TOP OF
PIPE TO EXISTING GROUND
D = INSIDE PIPE DIAMETER
d = DEPTH OF BEDDING
MATERIAL BELOW PIPE
CLASS A "CONCRETE CRADLE" AND/OR CLASS A "CONCRETE ENCASEMENT" IS NOT
REQUIRED UNLESS SPECIFIED ON THE PLANS. HOWEVER, WHERE UNEXPECTED
TRENCH CONDITIONS EXIST OR IMPROPER TRENCHING IS PERFORMED CLASS A
BEDDING MAY BE REQUIRED AS DETERMINED BY THE ENGINEER.
CLASS B BEDDING SHALL BE USED FOR ALL FLEXIBLE PIPE.
A. CLASS B NORMAL BEDDING SHALL BE USED FOR PVC PIPE UNLESS WET
CONDITIONS ARE ENCOUNTERED.
B. CLASS B IMPROVED BEDDING SHALL BE USED FOR OTHER FLEXIBLE PIPE, AND
FOR PVC PIPE IN WET CONDITIONS.
CLASS C BEDDING SHALL BE USED FOR ALL RIGID PIPE.
A. CLASS C ORDINARY BEDDING SHALL BE USED FOR ALL RIGID PIPE UNLESS WET
CONDITIONS ARE ENCOUNTERED.
B. CLASS C IMPROVED BEDDING SHALL BE USED FOR WET CONDITIONS EXISTING IN
THE TRENCH, AS DIRECTED BY THE ENGINEER, AT NO ADDITIONAL COST TO THE
OWNER. THE DIMENSIONS SHALL BE EQUAL TO THAT REQUIRED FOR "ROCK"
EXCAVATION (SEE SPECIFICATIONS).
COMPACTED GRANULAR BACKFILL
COMPACTED GRANULAR BACKFILL MATERIAL SHALL BE AN
APPROVED SAND MATERIAL FREE FROM DEBRIS, ORGANIC
MATERIAL AND STONES WITH 100% PASSING THE 20mm SIEVE
AND NOT MORE THAN 15% PASSING A NO. 200 SIEVE; TO BE
JETTED AND MECHANICALLY VIBRATED INTO PLACE AND
COMPACTED TO 95% DENSITY AS DETERMINED BY ASTM D698.
UNCOMPACTED EARTH BACKFILL MATERIAL MAY BE NATURAL
SOIL FREE FROM LARGE CLODS OR STONES, BRUSH, ROOTS
MORE THAN 2 INCHES IN DIAMETER, DEBRIS, AND JUNK.
FLOODING WITH WATER SHALL BE PROVIDED AS DIRECTED BY
THE ENGINEER.
COMPACTED EARTH BACKFILL SHALL CONSIST OF MATERIAL
EXISTING PRIOR TO TRENCHING OR SELECTED MATERIAL AS
DIRECTED BY THE ENGINEER, AND SHALL BE COMPACTED TO
90% DENSITY AS DETERMINED BY ASTM D698.
BACKFILL: BACKFILL MATERIAL AND COMPACTION
REQUIREMENTS SHALL CONFORM TO EITHER TYPE I, TYPE II OR
TYPE III AS SPECIFIED IN THE PLANS. ONE YEARS
MAINTENANCE WILL BE REQUIRED ON ALL BACKFILL.
BACKFILLING THROUGH ROCK: BACKFILLING THROUGH ROCK
SHALL BE PERFORMED AS SPECIFIED IN THE PARAGRAPH
BACKFILL ABOVE, EXCEPT THAT THE PIPE ZONE IS INCREASED
TO PROVIDE EIGHTEEN (18) INCHES OF COVER OVER THE PIPE.
WHEN APPROVED BY THE ENGINEER THE REMAINDER OF THE
BACKFILL MAY BE EXCAVATED ROCK PROVIDED THE
EXCAVATED ROCK HAS BEEN BROKEN UP SO THAT EARTH AND
ROCK WILL THOROUGHLY MIX AND NOT RESULT IN VOIDS
AROUND THE LARGER PIECES OF ROCK. ANY EXCESS ROCK
REMAINING AFTER THE TRENCH HAS BEEN BACKFILLED SHALL
BE REMOVED OR WASTED AS DIRECTED BY THE ENGINEER.
BACKFILLING UNDER PAVEMENT: BACKFILLING UNDER
EXISTING OR PROPOSED PAVEMENT SHALL BE PERFORMED AS
BACKFILL TYPE I OR BACKFILL - FLOWABLE FILL TO A LEVEL OF
TWO (2) FEET FROM THE BOTTOM OF THE PAVEMENT. THE
REMAINDER OF THE TRENCH SHALL BE BACKFILLED WITH
SELECTED MATERIAL, SUFFICIENTLY DAMP TO BE PROPERLY
COMPACTED IN LAYERS NOT EXCEEDING SIX (6) INCHES IN
DEPTH, COMPACTION SHALL BE PERFORMED WITH
MECHANICAL TAMPERS AND CONTINUED UNTIL A RELATIVE
DENSITY OF 100 PERCENT OF STANDARD DENSITY, IN
CONFORMANCE WITH ASTM D698 IS ATTAINED.
BACKFILLING UNDER GRAVEL STREETS: WHERE THE TRENCH
CROSSES OR IS IN EXISTING GRAVEL SURFACED STREETS, THE
BACKFILL SHALL BE COMPACTED AS PROVIDED IN THE
PARAGRAPH "BACKFILLING UNDER PAVEMENT".
CONCRETE CRADLE CONCRETE ENCASEMENT
NORMAL BEDDING IMPROVED BEDDING
ORDINARY BEDDING IMPROVED BEDDING
BACKFILL - FLOWABLE FILL BACKFILL TYPE I
BACKFILL TYPE III
1/4 D OR
150mm MIN.
ROBERT J. DOLE VA MEDICAL CENTER
WICHITA, KANSAS
NO. DESCRIPTION DATE
VA FORM 08-6231
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Se rv ic e
D i s ab l ed
Vet eran Owned Sma l l Business
SDVOSB
CVE
MR PROJECT NO: 0499-0121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANTS INSTALL NEW BOILERS IN
BUILDING 13
589A7-18-302
Project Director
2021-09-03
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
PROFESSIONAL ENGINEERING CONSULTANTS, P.A.
303 SOUTH TOPEKA, WICHITA, KS 67202
PHONE: (316)262-2691
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
ELECTRONIC SECURITY
MAGNA ENGINEERS
861 CORPORATE DRIVE, SUITE 210, LEXINGTON, KY 40503
PHONE: (859)309-2990
PHYSICAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304, BELLEAIR BEACH, FL 33786
PHONE: (502)836-4232
DRC SMT / DSB
CU502
CIVIL SITE
PIPE INSTALLATION DETAILS
File details come from the government source that posted it. Updated .