44-Attachment G - SUE - C. CIP 46142490 303 4th Ave SE SUE.pdf
PDF 929 KB Posted
- Solicitation number
- IFB-26-00085
- Issued by
- Hillsborough County, Florida
About this file
This is a Subsurface Utility Engineering (SUE) test hole data report prepared by ECHO UES, Inc. for Hillsborough County in Ruskin, Florida, documenting utility locations at 303 4th Avenue SE (CIP 46142490). The report documents five test holes (TH 1-1 through TH 1-5) excavated on May 8, 2023, to identify subsurface utilities prior to the culvert replacement project. The survey identified multiple utilities including water mains (cast iron and ductile iron pipe ranging from 2 to 6 inches in diameter), force mains (3-inch PVC), and other infrastructure at depths ranging from 0.72 to 4.90 feet below the surface. Test hole 1-5 presented challenges due to water infiltration and cave-in conditions, preventing visual verification of a possible 4-inch PVC utility. Coordinates are provided using NAD83/11 horizontal and NAVD88 vertical datums, with all utilities identified as belonging to Hillsborough County.
The report was prepared by EU/CM on May 9, 2023, and checked by MA on May 12, 2023, using survey crew members JB and PW. This SUE documentation supports the larger Lenwood Lane/1st Avenue NW/4th Avenue SE Culvert Replacements project, a competitive sealed bid solicitation by Hillsborough County Engineering and Operations Department valued at $1,958,866.12 for three culvert replacement locations. The project includes a 6% SBE (Small Business Enterprise) subcontractor participation goal, and all questions and interpretation requests must be submitted no later than 14 calendar days after solicitation issuance, site visit, or pre-bid conference, whichever is later.
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Crew Members: JB,PW
ECHO Project #: City, State: Ruskin, FL
General Location: 303 4th Ave SE
Coordinate Unit of Measure: US Survey Feet
EP= Edge of Pavement BC = Back of Curb BL = Baseline of Survey COORD = Survey Coordinates
N Horizontal: NAD83/11 Vertical: NAVD88
Utility Direction
1-1 FM PVC 3" 4.84' IRC NG N/A
HILLSBOROUGH
COUNTY
4.10' -0.74'
1-2 WM CI 2” 2.57' IRC NG N/A
HILLSBOROUGH
COUNTY
4.41' 1.84'
1-3 WM DIP 6” 1.72' IRC NG N/A
HILLSBOROUGH
COUNTY
4.22' 2.50'
1-4 WM DIP 6” 0.72' IRC NG N/A
HILLSBOROUGH
COUNTY
4.47' 3.75'
1-5 FM PVC 3" 4.90' IRC NG N/A
HILLSBOROUGH
COUNTY
3.84' -1.06'
Notes:
WM = Water Main GS = Gas Service CMP = Corrugated Metal Pipe SAN = Sanitary Sewer WS = Water Service CONC = Concrete VCP = Vitrified Clay Pipe Surface Type
FOC = Fiber Optic Cable NAVD = North American Vertical Datum
HUB = Survey Hub CL = Centerline
UNK = Unknown
TS = Traffic Signal
STL = Steel X = "X" in Concrete
1229664.64' 516825.74'
DBC = Direct Buried Cable PVC = Polyvinyl Chloride SLEEVE = Sleeve NL = Nail & Disk "ECHO TEST HOLE"
IRR = Irrigation Line
Utility Elevation
Northing Easting
PCCP = Prestressed Cylinder Concrete Pipe
1229688.62' 516801.20'
Datums: Ground Elevation
ST = Swing Ties
Date: 05/08/2023 Test Hole Data Report 23-077 4803 George Road, Ste. 350
Tampa, Florida 33634 400 SR 434, Ste. 1024 Oviedo, Florida 32765
ECHO UES, Inc.
www.echoues.com
888.778.ECHOFinancial Project #: N/A
Truck No.: D-13 - GROW, INSPIRE, MAKE A DIFFERENCE-
GM = Gas Main SL = Street Light CP = Concrete Pipe PE = Polyethylene Pipe
N/A = Not Applicable
Utility Type Utility Material Identified By: Abbreviations Offset Measured From:
BE = Buried Electrical RCW = Reclaimed Water AC = Transite GALV = Galvanized Pipe HUB = Survey Hub
CI= Cast Iron HDPE = High Density Polyethylene Pipe IRC = Iron Rod & Cap "ECHO TEST HOLE" NAD = North American DatumBT = Buried Telephone
RCP = Reinforced Concrete Pipe NG = Natural Ground X = "X" in Concrete
RW = Right of Way
Identified By Surface Type Surface
Thickness inches
Apparent Utility Owner
TH# 1-5 - POSSIBLE 4" PVC, UNABLE TO VISUALLY VERIFY SIZE AND MATERIAL DUE TO WATER AND CAVE-IN.
1229685.54' 516846.61'
1229687.22' 516809.66'
STM = Storm Sewer UNK = Unknown Utility CPP = Corrugated Plastic Pipe ASPH = Asphalt
Cross Sectional View
CATV = Cable Television BED = Buried Electrical Duct DCT = Duct CONC = Concrete FM = Force Main BTD = Buried Telephone Duct DIP = Ductile Iron Pipe
Test Hole Utility Type Utility
Material
Utility Size Outside
Diameter inches
Utility Manual Depth feet
1229664.94' 516804.19'
Checked by: MA Date: 05/12/2023
Prepared by: EU/CM Date: 05/09/2023
© 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom
W(B)
W B
W B
W B
W(B)
W(B) W(B)
W(B) W(B)
W(B)
S(B)
S(B)
S(B) S B
S B
S( B) S(B)
B F O C B
BFOC(B)
BFOC(B)
BFOC(B)
BFO
C(B
BF
OC
(B
TH
TH
TH
TH
TH
WATER
1-1
1-2
1-3 1-4
1-5
Feet
0 20 40
23-077 HC - 303 4th Ave SE
)25 E;H,%,7 38532SES 21/<
7H,S ,S 127 A S859E<
File details come from the government source that posted it. Updated .