20-26-00085 Plans - 46142473 1st Ave NW SS Drainplan 2025-07-11.pdf
PDF 6 MB Posted
- Solicitation number
- IFB-26-00085
- Issued by
- Hillsborough County, Florida
About this file
This document consists of final construction plans for Hillsborough County Public Works Administration Engineering & Operations Department for CIP #46142473, the 1st Avenue NW Culvert Replacement project located at 111 1st Avenue NW in Ruskin, Florida. The project involves the in-kind replacement of two existing 18-inch reinforced concrete pipes (RCPs) spanning approximately 0.027 miles (145 linear feet) between stations 10+00.00 and 11+45.34. Work includes milling and resurfacing asphalt pavement (366 square yards), constructing 18-inch Class IV RCP sections with slopes of 0.46% and 1.89%, installing three concrete endwalls with manatee grates, removing and relocating existing water mains and force mains, adjusting underground communications infrastructure, and implementing stormwater pollution prevention measures. The plans were prepared by Haylee C. LaTorre, P.E. (License No. 61732) of Plummer Associates Inc. under Purchase Order No. 221215015 and Work Order No. PWPDD20210026, with final plans dated July 11, 2025. The project is governed by Florida Department of Transportation FY 2023-2024 Standard Plans, the 2023 Manual of Uniform Minimum Standards for Design and Construction (Florida Greenbook), the 2024 FDOT Drainage Manual, and Hillsborough County Public Works Department standards.
The construction plans indicate the project must comply with temporary traffic control restrictions limiting road closures to 8:00 AM to 6:00 PM with a maximum closure period of four weeks, requiring notification to adjacent property owners 48 hours in advance and maintenance of pedestrian crossing access per ADA requirements. Utility coordination is mandatory with Hillsborough County Water Resources Department, Frontier Communications, and Charter Communications, with specialized construction notes addressing protection of existing water mains and force mains during excavation and grading operations. The project includes erosion and sediment control measures consisting of 380 linear feet of silt fence, inlet protection devices, temporary stabilization practices using artificial coverings and turf, and permanent stabilization through asphalt, concrete, and sodding. Environmental considerations include 0.03 acres of wetland area within the project boundary with temporary impact areas totaling 95.51 square feet and permanent impact areas of 24.49 square feet, requiring wetland flagging and protection measures throughout construction. The contract specifies compliance with Section 104 Erosion Control Plan requirements, FDEP Rule Chapter 62-25, Hillsborough County EPC wetlands regulations, and Ordinance 21-42 regarding nitrogen and phosphorous fertilizer restrictions.
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
7 8
Ta mi am i
19th Ave.
Gulf City
Ruskin
IS. 674
RUSKIN
N
HILLSBOROUGH COUNTY
PUBLIC WORKS ADMINISTRATION
ENGINEERING & OPERATIONS DEPARTMENT
FINAL CONTRACT PLANS
111 1ST AVE NW
CRRP
CIP #46142473 LOCATION OF PROJECT
THE BOARD OF COUNTY COMMISSIONERS
PLANS PREPARED BY:
HAYLEE C. LATORRE, P.E., NO. 61732
PLUMMER ASSOCIATES INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
(813) 641-1200
PURCHASE ORDER NO: 221215015
WORK ORDER NO: PWPDD20210026
ENGINEER OF RECORD:HAYLEE C. LATORRE, P.E.
P.E. NO.: 61732
NTS
SUN CITY
CENTER
BEGIN PROJECT
℄ CONSTR. 1ST AVE NW
STA. 10+00.00
N 1231087.0440 E 515300.6724
LOCATION MAP
LENGTH OF PROJECT
DESCRIPTION LIN. FT. MILES
0.027145
BRIDGES
NET LENGTH OF PROJECT
EXCEPTIONS
GROSS LENGTH OF PROJECT
COUNTY C.I.P. PROJECT MANAGER VANESSA HERNANDEZ, C.F.M.
CONTRACT PLANS COMPONENTS:
ROADWAY PLANS
INDEX OF DRAINAGE PLANS
SHEET NO. SHEET DESCRIPTION
GOVERNING DESIGN STANDARDS:
Florida Department of Transportation, FY 2023-2024 Standard Plans for Road and Bridge Construction and applicable Interim Revisions (IRs), 2023 Manual of Uniform Minimum Standards for Design, Construction and Maintenance (Florida Greenbook), 2024 FDOT Drainage Manual, Florida Administrative Codes, 2023 Hillsborough County Public Works Department Stormwater Technical Manual, and Hillsborough County Public Works Technical Bulletins.
Standard Plans for Road Construction and associated IRs are available at the following website: http://www.fdot.gov/design/standardplans
GOVERNING STANDARD SPECIFICATIONS:
REVISIONS
DATE BY DESCRIPTION
CIP NO.
2546142473
KEN HAGAN CHAIR
GWEN MYERS VICE CHAIR
DONNA CAMERON CEPEDA CHAPLAIN
HARRY COHEN COMMISSIONER
PAT KEMP COMMISSIONER
CHRISTINE MILLER COMMISSIONER
JOSHUA WOSTAL COMMISSIONER
KEY SHEET
SIGNATURE SHEET
SUMMARY OF PAY ITEMS
DRAINAGE MAP
TYPICAL SECTION
GENERAL NOTES
ROADWAY PLAN
CROSS SECTIONS
STORMWATER POLLUTION PREVENTION PLAN
TEMPORARY TRAFFIC CONTROL PLANS
TEMPORARY TRAFFIC CONTROL PLANS
UTILITY ADJUSTMENTS
MISCELLANEOUS DETAILS
SUMMARY OF QUANTITIES
9 - 11 12-A
SQ-1
1ST AVE NW
ROADWAY (ROAD 2)
SECTION 07, TOWNSHIP 32S, RANGE 19E
FISCAL
YEAR
SHEET
NO
0000.00 0000.00
0000.00
0.000 0.000 0.027 0.000 0.027
END PROJECT
℄ CONST. 1ST AVE NW
STA. 11+45.34
N 1231115.4697 E 515443.4307
Hillsborough County Public Works Standard Specifications for Construction OCTOBER_2023 and FDOT Standard Specifications for Roadway and Bridge Construction, Divisions II & III as directed under the Hillsborough County Standard Specifications for Construction.
LAST UPDATE: 07/11/2025
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\1 KEY SHEET.dwg10:43:04 AM2/22/2024HLATORRE
SU
N
CI
TY
TH
E O
F F
IC
IA
L
R E C
OR
D O
F T
H
IS
S H E E T
IS
T
H E E
LE
C
TR
ON
IC
F
IL
E D
IG
IT
AL
LY
S
IG
N E D A
N D S
E
AL
E D U
N D E R R
U
LE
1G
-2
3.
4, F
.A .C
NOTE: THE SCALE OF THESE PLANS MAY
HAVE CHANGED DUE TO REPRODUCTION.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text N
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text U.S. 41
AutoCAD SHX Text U.S. 301
AutoCAD SHX Text I-75
AutoCAD SHX Text S.R. 674
AutoCAD SHX Text S.R. 60
AutoCAD SHX Text S.R. 39
AutoCAD SHX Text U.S. 41
AutoCAD SHX Text I-275
AutoCAD SHX Text Race TracK Rd.
AutoCAD SHX Text Ehrlich Rd
AutoCAD SHX Text Dale Mabry Hwy.
AutoCAD SHX Text Hillsborough Ave.
AutoCAD SHX Text S.R. 580
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR
THE FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004‚ F.A.C.
SHEET NO. SHEET DESCRIPTION
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS SHT. NO.
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\2 SIGNATURE SHEET.dwgLaTorre, Haylee 7/11/2025 10:43:13 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
SIGNATURE SHEET 2
STATE OF
No.
PR
O
FESSIONAL ENGIN
EE
R
HA
YL
EE C. LATORRE
FLORI'A
61732
KEY SHEET
SIGNATURE SHEET
SUMMARY OF PAY ITEMS
DRAINAGE MAP
TYPICAL SECTION
GENERAL NOTES
ROADWAY PLAN
CROSS SECTIONS
STORMWATER POLLUTION PREVENTION PLAN
TEMPORARY TRAFFIC CONTROL PLANS
TEMPORARY TRAFFIC CONTROL PLANS
UTILITY ADJUSTMENTS
MISCELLANEOUS DETAILS
SUMMARY OF QUANTITIES
9 - 11 12-A
SQ-1
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY
ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED AND SEALED, AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
PLUMMER ASSOCIATES INC.
2 URBAN CENTRE,
4890 KENNEDY BLVD, SUITE 985
HAYLEE C. LATORRE, P.E. NO. 61732
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS SHT. NO.
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\3 SUMMARY OF PAY ITEMS.dwgLaTorre, Haylee 7/11/2025 10:43:23 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
SUMMARY OF PAY ITEMS 3
B
eg. S
TA. 10+00.00
E nd S
TA. 11+45.34
CONTROL POINT
N: 1231095.85 E: 515406.48
ELEV: 2.88
LANDMARK 2000
CONTROL POINT
N: 1231099.55 E: 515274.95
ELEV: 2.96
CAPPED IRON ROD SET (LB 5122)
2.8 2.1
1.2 1.9 3.0
2.78 3.09
2.88
3.1
2.7
2.7
INV 12" RCP
ELEV= 1.03
INV 12" RCP
ELEV= 1.25
INV 18" RCP
ELEV= 0.25
2.94
2.95
3.34
2.8 2.5
1.0
2.3
2.6
2.7
0.6 1.2
2.3
3.4 3.6
3.45 3.41 3.04
3.1 3.2 3.2
T
2.94 2.83
3.00
2.9 3.4
3.25 3.28
2.64 2.8
2.5 2.4
TOP ELEV=2.79
INV 18" RCP
ELEV= 0.30
3.19
3.02
3.2
3.0 2.5
INV 18" RCP
ELEV= -0.97
2.1
INV 15" ADS
ELEV= -0.02
V V
C2-8
C2-7
C2-6 C2-5
C2-4
C2-3 C2-2 C2-1
INV 18" RCP
ELEV= 0.20
INV 18" RCP
ELEV= 0.28
2.5 2.0
1.0 0
2.5
2.0 1.0 0 -1.0
-1.0
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS SHT. NO.
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\4 DRAINAGE MAP.dwgLaTorre, Haylee 7/11/2025 10:46:56 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
DRAINAGE MAP 4
N
1"
LEGEND
EXIST. FLOW DIRECTION
EXIST. STRUCTURE ID NO.
PROP. STRUCTURE ID NO.
S-#
S-#
S-1A
EXIST DITCH TOB
REPLACE EXIST 18" RCPs
℄ OF CONST.
S-1
S-2
S-3
EXIST. DITCH TOS EXIST 18" RCPs
EXIST. GRATE INLET
HYDRAULIC & HYDROLOGY NOTES:
THIS PROJECT PROPOSES AN IN-KIND REPLACEMENT OF TWO (2) EXISTING 18" RCPs.
THE OUTFALL PIPE INVERTS WILL BE MAINTAINED. ALTHOUGH THE LENGTHS OF THE
PROPOSED OUTFALL PIPES ARE PROPOSED TO BE SHORTENED (TO AVOID IMPACTS
TO MANGROVES AND IMPROVE MAINTENANCE ACCESS), THIS IS NOT EXPECTED TO
HAVE ANY HYDRAULIC & HYDROLOGIC IMPACTS. NO UPSTREAM OR DOWNSTREAM
IMPACTS SHOULD RESULT FROM THIS CULVERT REPLACEMENT PROJECT.
BEGIN PROJECT
STA. 10+00.00
END PROJECT
STA. 11+45.34
1ST AVE NW
1S T
S T
N W
PROP. 6"-12" CLEAN
RUBBLE RIPRAP
TEMPORARY WETLAND
IMPACT AREA (17.06 SF)
TEMPORARY WETLAND
IMPACT AREA (78.45 SF)
WETLAND FLAG (TYP)
WETLAND LINE
WETLAND AREA WITHIN PROJECT
BOUNDARY = 0.03 AC (1404 SF)
TOTAL IMPERVIOUS SURFACE AREA
PROPOSED = 44 SF (HEAD/END WALLS AT
S-1, S-2, AND S-3)
TOTAL PERVIOUS SURFACE AREA PROPOSED
= 38 SF (RUBBLE RIPRAP AT S-1 AND S-2)
MHWL=0.52' ESTIMATED EXIST GRADES BASED
IN LIDAR AND FIELD INSPECTIONS
ROW
PROPOSED AREA FOR
DREDGING BELOW MHWL
APPROX 36 SF
PROPOSED AREA FOR
DREDGING BELOW MHWL
APPROX 2 SF
PROP. PIPE END GUARD/MANATEE
GRATE-FIXED, NON-HINGED
(SEE DETAIL SHEET 14)
PROP. PIPE END GUARD/MANATEE
GRATE-FIXED, NON-HINGED
(SEE DETAIL SHEET 14)
PROP. PERMANENT
IMPACT AREA (9.94 SF)
PROP. PERMANENT
IMPACT AREA (14.55 SF)
3.6'1.6'
4.2'3.4' 1.5'
3.9'
3.9'
3.4'
0.6'
1.4'
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\5 TYPICAL SECTION.dwgLaTorre, Haylee 7/11/2025 10:47:07 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
TYPICAL SECTION 5
EXIST. GRADE
TYPICAL SECTION
1ST AVE NW STA 10+00 TO 11+45.34
NOT TO SCALE (VERTICAL SCALE EXAGGERATED)
TRAFFIC DATA
ESTIMATED OPENING YEAR = N/A (EXISTING)
ESTIMATED DESIGN YEAR = UNKNOWN
POSTED SPEED = 25 MPH
DESIGN SPEED = 25 MPH
LOCAL ROAD
MILLING AND RESURFACING (STA. 10+00.00 TO STA. 11+45.34)
MILLING: MILL EXISTING PAVEMENT 1-1/2" AVERAGE DEPTH
SURFACE: TYPE SP STRUCTURAL COURSE (1.5")
NEW CONSTRUCTION (CROSS DRAIN PAVEMENT RESTORATION)
SURFACE: 1.5" ASPHALT TYPE SP (TRAFFIC C)
BASE: OBG 11
R/W LINE (PER HC R/W
INVENTORY MAP_
1ST AVE NW ROW (VARIES)
APPROX. 50'-59' WITHIN PROJECT AREA
R/W LINE (PER HC R/W
INVNTORY MAP)
8.5'±
TRAVEL
LANE
8.5'±
TRAVEL
LANE
PROP. ASPHALT RESURFACING
MAINTAIN EXIST. GRADE
EXIST. BASE
6'
CLEAR
ZONE
6'
CLEAR
ZONE
1.34% 0.92%
NOTES:
1. NO UNDERGROUND INSTALLATIONS OR IMPROVEMENTS HAVE BEEN LOCATED, EXCEPT AS NOTED.
2. NO INSTRUMENTS OF RECORD REFLECTING EASEMENTS, RIGHTS OF WAY, AND/OR OWNERSHIP WERE
FURNISHED TO THIS SURVEYOR, EXCEPT AS SHOWN.
3. UNLESS OTHERWISE SHOWN HEREON, NO JURISDICTIONAL WETLAND AREAS OR OTHER TOPOGRAPHIC
FEATURES HAVE BEEN LOCATED.
4. THIS OFFICE DID NOT PERFORM A TITLE SEARCH OF THE PUBLIC RECORDS TO VERIFY OR CONFIRM
OWNERSHIP NOR WAS ONE PROVIDED BY THE CLIENT.
5. COORDINATES SHOWN HEREON ARE GRID COORDINATES, EXPRESSED IN US SURVEY FEET, BASED ON THE
FLORIDA WEST ZONE TRANSVERSE MERCATOR STATE PLANE COORDINATE SYSTEM NAD83 (2011
ADJUSTMENT)
6. ELEVATIONS SHOWN HEREON ARE EXPRESSED IN US SURVEY FEET AND WERE DERIVED FROM
HILLSBOROUGH COUNTY BENCHMARK "LANDMARK," HAVING AN ELEVATION OF 2.882, NAVD88.
7. THIS IS A TOPOGRAPHIC SURVEY OF AREAS REQUESTED BY THE CLIENT.
8. THE LAST DAY OF FIELD WORK WAS SEPTEMBER 13, 2021.
9. THE RIGHT-OF-WAY LINES WERE NOT SURVEYED PER HILLSBOROUGH COUNTY PROJECT MANAGER.
LEGEND:
WOOD BOLLARD
COMMUNICATIONS PEDESTAL
COMMUNICATIONS VAULT
WATER VALVE
WETLANDS FLAG
ABBREVIATIONS:
ADS = TRADE NAME FOR A CORRUGATED PLASTIC PIPE
ELEV = ELEVATION
INV = INVERT
RCP = REINFORCED CONCRETE PIPE
T
V
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS SHT. NO.
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\6 GENERAL NOTES.dwgLaTorre, Haylee 7/11/2025 10:58:34 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
GENERAL NOTES 6
SURVEY NOTES, SYMBOLS, AND LEGEND
1. COMPLY WITH ALL STATE, COUNTY, AND LOCAL ORDINANCES AND OBTAIN NECESSARY WORK PERMITS THAT ARE REQUIRED
PRIOR TO CONSTRUCTION.
2. LOCATION, ELEVATION, AND DIMENSIONS OF EXISTING UTILITIES, STRUCTURES, AND OTHER FEATURES ARE SHOWN IN
ACCORDANCE WITH THE BEST INFORMATION AVAILABLE AT THE TIME OF THE PREPARATION OF THESE PLANS, BUT DO NOT PURPORT TO BE ABSOLUTELY CORRECT. VERIFY THE LOCATION, ELEVATION, AND DIMENSIONS OF ALL EXISTING
UTILITIES, STRUCTURES, AND OTHER FEATURES AFFECTING THE WORK.
3. PROVIDE TWO WORKING DAYS NOTICE TO UTILITY AGENCY/OWNER’S (UAO), AND HILLSBOROUGH COUNTY TRAFFIC OPERATIONS, IN ORDER TO LOCATE AND IDENTIFY THEIR EXISTING UNDERGROUND FACILITIES PRIOR TO CONSTRUCTION, AS ESTABLISHED BY THE "UNDERGROUND FACILITY DAMAGE PREVENTION AND SAFETY ACT". KNOWN UAO’S ARE:
GENERAL NOTES
4. COORDINATE CONSTRUCTION SCHEDULING WITH UTILITY AGENCY/OWNER’S. MEET WITH UAOs PRIOR TO THE PRE-CONSTRUCTION CONFERENCE TO ADJUST THEIR SCHEDULES TO COINCIDE WITH THE CONSTRUCTION SCHEDULE.
5. UTILITY ADJUSTMENTS SHOWN IN THIS CONTRACT PLAN SET MUST BE PERFORMED BY THE UTILITY AGENCY WHEN UTILITY
CONSTRUCTION PLANS ARE NOT INCLUDED IN THE CONTRACT PLAN SET.
6. ERECT EROSION CONTROL DEVICES PRIOR TO LAND ALTERATIONS, MAINTAIN THEM DURING CONSTRUCTION, AND REMOVE THEM FOLLOWING SOIL STABILIZATION AND FINAL DRESSING. INSTALL AND MAINTAIN EROSION CONTROL DEVICES AS REQUIRED BY ACTUAL SITE CONDITIONS TO REFLECT PROJECT PHASING REQUIREMENTS, AND AS DIRECTED BY THE
COUNTY'S ENGINEER.
7. DO NOT DISCHARGE DIRECTLY TO RECEIVING WATERS OR EXISTING CONVEYANCES THAT DISCHARGE TO RECEIVING WATERS OR WETLAND SYSTEMS DURING DEWATERING OPERATIONS. UTILIZE TEMPORARY SEDIMENT BASINS OR TRAPS TO COLLECT THE DISCHARGE FROM DEWATERING ACTIVITIES TO ELIMINATE THE POTENTIAL FOR OFFSITE SEDIMENT TRANSPORT.
8. CONNECTIONS TO ADJACENT PROPERTIES SHOWN ON THE PLANS MAY BE MOVED, ADJUSTED, MODIFIED, ADDED OR DELETED AT THE PROPERTY OWNER’S REQUEST SUBSEQUENT TO APPROVAL BY THE COUNTY'S ENGINEER.
9. THE COUNTY MAY SUBSTITUTE A GRAVITY WALL FOR A GRADED AND HARMONIZED SLOPE OR VICE VERSA PURSUANT TO THE
PROPERTY OWNER'S REQUEST AND CONTINGENT UPON APPROVAL BY THE COUNTY’S ENGINEER.
10. CONNECTION TO EXISTING ACCESS NOT INDICATED ON THE PLANS MUST BE MADE AT THE DIRECTION OF THE COUNTY'S
ENGINEER.
11. ALL CONNECTION APPROVALS BY THE COUNTY'S ENGINEER MUST BE SUBJECT TO CONFORMANCE WITH APPLICABLE STANDARDS, CODES AND REGULATIONS, AND CONDITIONED UPON GRANT OF RIGHT OF ENTRY BY THE PROPERTY OWNER.
12. ALL EXISTING DRAINAGE STRUCTURES WITHIN THE RIGHT OF WAY MUST BE REMOVED UNLESS SHOWN ON THE PLANS AS
TO REMAIN.
13. PROPOSED PIPE MUST BE REINFORCED CONCRETE PIPE (RCP) CLASS IV UNLESS OTHERWISE NOTED ON THE PLANS.
14. SPECIAL ATTENTION IS DIRECTED TO THE FACT THAT PORTIONS OF SOME DRAINAGE STRUCTURES EXTEND INTO THE
STABILIZED PORTION OF THE ROAD BED AND EXTREME CAUTION WILL BE NECESSARY IN STABILIZATION OPERATIONS AT
THOSE LOCATIONS.
15. ALL CONCRETE COLLARS AND CONCRETE JACKETS MUST BE CURED AND INSPECTED TO BE FREE OF CRACKING PRIOR TO
BACKFILLING.
16. TREE TRIMMING MAY BE REQUIRED TO PROVIDE VERTICAL OR HORIZONTAL CLEARANCES OR ADEQUATE SIGHT DISTANCE AS DIRECTED BY THE COUNTY'S ENGINEER. ANY TREE TRIMMING REQUIRED SHALL BE PERFORMED OR DIRECTED BY A CERTIFIED ARBORIST AND COMPLY WITH ANSI A-300 STANDARDS AND BEST PRACTICES. ALL EXPENSES INCURRED FOR
THIS WORK WILL BE INCLUDED IN THE BID PRICE FOR CLEARING AND GRUBBING.
17. ANY DAMAGE TO STATE, COUNTY, OR LOCAL ROADS CAUSED BY HAULING OR EXCAVATION EQUIPMENT MUST BE REPAIRED TO
THE SATISFACTION OF THE COUNTY'S ENGINEER AT THE CONTRACTOR’S EXPENSE.
18. ANY U.S.C. & G.S. MONUMENT WITHIN LIMITS OF CONSTRUCTION IS TO BE PROTECTED. IF IN DANGER OF DAMAGE, PROJECT
ENGINEER SHOULD NOTIFY;
DIRECTOR, NATIONAL GEODETIC SURVEY
1315 EAST-WEST HIGHWAY
SILVER SPRING, MARYLAND 20910-3282
PHONE: (301) 713-3242
19. ALL STATION AND OFFSET REFERENCES ARE TO BASELINE OF SURVEY, UNLESS OTHERWISE NOTED.
20. BEARINGS AND COORDINATES ARE REFERENCED TO THE FLORIDA STATE PLANE COORDINATE SYSTEM, FLORIDA WEST
ZONE, NORTH AMERICAN DATUM OF 1983, 2011 ADJUSTMENT. ALL ELEVATIONS ARE REFERENCED TO N.A.V.D. 1988.
21. MISCELLANEOUS OR INCIDENTAL ITEMS SUCH AS BYPASS PUMPING, COFFERDAMS AND SPECIAL COFFERDAMS BEYOND
DEWATERING, CUTTING, PATCHING, GRADING, SAW-CUTTING, CONCRETE PIPE COLLARS, ELECTRICAL HARDWARE, BOLTS, NUTS, FITTINGS, VIBRATION MONITORING, ETC., OR OTHER ANCILLARY ITEMS MAY BE REQUIRED TO COMPLETE THE CONSTRUCTION AS INDICATED ON THE PLANS OR IN THE SCOPE OF WORK. IF NO SPECIFIC BID ITEM IS SHOWN, SUCH MISCELLANEOUS OR INCIDENTAL ITEMS ARE TO BE INCLUDED IN THE UNIT PRICE (S) FOR THE ITEM (S) WITH WHICH THEY ARE ASSOCIATED. SEPARATE PAYMENT FOR MISCELLANEOUS OR INCIDENTAL ITEMS SHALL NOT BE MADE BY THE COUNTY.
ALL COMPONENTS SHOWN AND DESCRIBED ON THE BID DOCUMENTS ARE TO BE INCLUDED IN THE BID ITEMS SHOWN ON
THE BID FORM.
HC UTILITY (WATER RESOURCES DEPT)
WARREN GILBREATH
GILBREATHW@HILLSBOROUGHCOUNTY.ORG
813-209-3075
FRONTIER BUSINESS
RANDALL JAMES
RANDALL.JAMES@FTR.COM
813-892-9692
CHARTER COMMUNICATIONS
PAUL BUSTAMANTE
PAUL.BUSTAMANTE@CHARTER.COM
O: 813-302-0749 C:813-538-2924
CONTROL POINT
N: 1231095.85 E: 515406.48
ELEV: 2.88
LANDMARK 2000
CONTROL POINT
N: 1231099.55 E: 515274.95
ELEV: 2.96
CAPPED IRON ROD SET (LB 5122)
2.8
2.1
1.2 1.9 3.0
2.78 3.09
2.88 3.1
2.7 2.7
INV 12" RCP
ELEV= 1.03
INV 12" RCP
ELEV= 1.25
INV 18" RCP
ELEV= 0.25
2.94
2.95
3.34
2.8 2.5
1.0
2.3
2.6
2.7
0.6 1.2
2.3
3.4 3.6
3.45 3.41 3.04
3.1 3.2 3.2
T
2.94 2.83
3.00
2.9 3.4
3.25
3.28
2.64
2.8
2.5 2.4
TOP ELEV=2.79
INV 18" RCP
ELEV= 0.30
3.19
3.02
3.2
3.0 2.5
INV 18" RCP
ELEV= -0.97
2.1
INV 15" ADS
ELEV= -0.02
V V
C2-8
C2-7
C2-6 C2-5
C2-4
C2-3 C2-2 C2-1
INV 18" RCP
ELEV= 0.20
INV 18" RCP
ELEV= 0.28
1 ST AVENUE NW
CARLYLE BLVD (P)
(ASPHALT)
ST
S
TR
EE
T
N W
3R D
ST
RE
ET
(P
(A
SP
HA
LT
LOT 194
FOLIO No. 055866-0000
PORTIONS OF LOTS 87
THROUGH 90, INCLUSIVE
FOLIO No. 055803-0000
FOLIO No. 056240-0000
MAP OF RUSKIN CITY IN HILLSBOROUGH COUNTY, FLORIDA
PLAT BOOK 5, PAGE 75
8" CONCRETE
HEADWALL
NOTE:
CONFLICTING PIPE SIZES AND
MATERIALS WERE CONFIRMED.
TH
TH
TH
TH
TH-4
TH-1
TH-2
TH-3
B
eg. S
TA. 10+00.00
E nd S
TA. 11+45.34
2.
2.
1.
2.5 2.0
1.0 0
2.5
2.0
1.0 0
-1.0
2.5
2.0
1.0 0 -1.0
-1.0
2.
1.
-1 .0
BTV(
D)
BTV(
D)
BTV(
D)
BTV(
D)
BT
V( D)
BTV(D)
BTV(D)
BTV(D)
BTV(D)
BTV(D)
BTV(D)
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BT
V
BT
V
BT
V
BT
V BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV
BT
BT
BT
BT
BT
BT
BT
BT
BT
B T
B T
B T
B T
B T
B T
B T
B T
B T
B T
B T
B T
BT
BT
BT
BT
BT
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS SHT. NO.
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\7 ROADWAY PLAN.dwgLaTorre, Haylee 7/11/2025 10:58:57 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
ROADWAY PLAN 7
S-1
STA. 10+86.52 (27.3' RT.)
U-TYPE CONC. ENDWALL 1:2
SLOPE W/ GRATE PER SP
INDEX 430-011
FL -0.97 (18" RCP)
S-1A
STA. 10+98.76 (36.0' LT.)
EXIST. GRATE INLET
GRATE EL. 2.79
FL 0.28 (N) (18" RCP)
FL 0.30 (E) (18" RCP)
FL 0.20 (S) (18" RCP)
S-2
STA. 10+36.47 (25.5' RT.)
U-TYPE CONC. ENDWALL 1:2
SLOPE W/ GRATE PER FDOT
SP INDEX 430-011
FL -0.02 (18" RCP)
S-3
STA. 10+51.38 (28.4' LT.)
WINGED CONC. ENDWALL PER
FDOT SP INDEX 430-040
FL 0.25 (18" RCP)
DRAINAGE STRUCTURES TABLE
N
1"
0'
NOTES:
1. SOD ALL DISTURBED PERVIOUS AREAS.
2. THE CONSTRUCTION EQUIPMENT STAGING WILL BE LIMITED
TO THE 1ST AVE R/W. NO STAGING IS ALLOWED WITHIN 25’
OF THE WETLAND LIMITS.
PAVEMENT RESTORATION PER
HC UAG, APPENDIX K (9 SY)
S-1A
S-1
S-2
S-3
PAVEMENT RESTORATION PER
HC UAG, APPENDIX K (13 SY)
MILL AND RESURFACE
ASPHALT PAVEMENT (366 SY)
REMOVE EXIST. 18" RCP/15" ADS PIPE AND
CONST. 59 LF 18" CLASS IV RCP @ 0.46% SLOPE
REMOVE EXIST. 18" RCP, AND CONST. 62
LF 18" CLASS IV RCP @ 1.89% SLOPE
BEGIN PROJECT
STA. 10+00.00
END PROJECT
STA. 11+45.34
REMOVE AND REPLACE WOOD BOLLARD
REMOVE AND REPLACE
WOOD BOLLARD
EXIST. 12" RCP TO REMAIN
EXIST. CONC. HEADWALL TO REMAIN
EXIST. 18" RCPs TO REMAIN
(PIPE DESILTING)
EXIST. GRATE INLET TO REMAIN
(PROVIDE INLET PROTECTION).
CONNECT PROP. 18" RCP CLASS IV TO EXIST. GRATE INLET
S-#
LEGEND
MILL AND RESURFACE
PAVEMENT RESTORATION
EXIST. STRUCTURE ID NO.
EXIST. STRUCTURE ID NO.
S-#
S-#
ESTIMATED EXIST GRADES BASED
IN LIDAR AND FIELD INSPECTIONS
EXIST WETLAND LINE
MATCH EXIST. GRADE (TYP)
R/W LINE PER HC R/W
INVENTORY MAP
R/W LINE PER HC R/W
INVENTORY MAP
MHWL=0.52'
TEMPORARY WETLAND
IMPACT AREA (17.06 SF)
TEMPORARY WETLAND
IMPACT AREA (78.45 SF)
WETLAND FLAG (TYP)
REMOVE AND DEFLECT 10LF
OF EXIST 2" PVC WM
WITH (4) 45 DEG BENDS.
REMOVE AND DEFLECT 10LF
OF EXIST 3" PVC FM
WITH (4) 45 DEG BENDS
PROP. PIPE END GUARD/MANATEE
GRATE-FIXED, NON-HINGED
(SEE DETAIL SHEET 14)
PROP. PIPE END GUARD/MANATEE GRATE-FIXED,
NON-HINGED (SEE DETAIL SHEET 14)
REMOVE ASH TREE OF
APPROXIMATE DIAMETER 26"
REMOVE PINE TREE OF
APPROXIMATE DIAMETER 34"
REMOVE ASH TREE OF
APPROXIMATE DIAMETER 26"
REMOVE PALM TREE OF
APPROXIMATE DIAMETER 36"
PROP. PERMANENT
IMPACT AREA (9.94 SF)
PROP. PERMANENT
IMPACT AREA (14.55 SF)
3.6'
4.2' 3.4'
3.9'
3.9'
3.4'
0.1'
0.1'
0.6' 1.5'
EXIST UG CATV
SPECTRUM
4-4" CONDUIT 2-W/BT
FRONTIER
4-4" CONDUIT 2-W/BT
FRONTIER
PROP. 1-1/2" W/FOC
FRONTIER
PROP. UG CATV
SPECTRUM
EXIST. 18" RCPs TO REMAIN
(PIPE DESILTING)
PROP. 1-1/2" W/FOC ADJUST/PROTECT FOR S-3 APPROX DEPTH 48"/52" BORED
FRONTIER
COMMUNICATION CABINET
FRONTIER
PEDESTAL
FRONTIER
10+43.73 -5
0 20 400204060
10+91.82 -5
0 20 400204060
0.27%
4'
1" = 20' Horizontal 1" = 5' Vertical
LaTorre, Haylee
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS SHT. NO.
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\8 CROSS SECTIONS.dwg7/11/2025 10:59:01 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
CROSS SECTIONS 8
Regular Exc.Embankment A(sf) V(cy)V(cy)A(sf)
EXIST. GRADE
EXIST. 18" RCPs
REMOVE EXIST. 18" RCP
CONST. 18" RCPCONNECT. PROP. 18" RCP
TO EXIST. GRATE INLET STA. 10+86.52 (27.3' RT.)
PROP. U-TYPE CONC. ENDWALL
1:2 SLOPE PER FDOT INDEX 430-011.
STA. 10+36.47 (25.5' RT.)
PROP. U-TYPE CONC. ENDWALL
1:2 SLOPE PER FDOT INDEX 430-011
REMOVE EXIST.
18" RCP/15" ADS PIPE
CONST. 18" RCP
STA. 10+36.47 (25.5' RT.)
PROP. CONC. HEADWALL PER
FDOT SP INDEX 430-040
EXIST. GRADE
PROP. GRADE (TYP.)
PROP. GRADE 1:6
1ST AVE NW
EOP
1ST AVE NW
EOP
℄ OF CONST.
5% SLOPE
MATCH EXIST GRADE
MATCH EXIST GRADE
MATCH EXIST GRADE
MATCH EXIST GRADE
PROTECT AND MAINTAIN
EXIST 3" PVC FM AT PIPE
INVERT ELEVATION -0.95'.
(DESIGN EXCEPTION)
PROTECT AND MAINTAIN
EXIST 2" PVC WM AT PIPE INVERT ELEVATION -1.41'.
(DESIGN EXCEPTION)
EXIST 2" PVC WM
NOTE: BASE LEVEL A SUE WAS CONDUCTED
ADJACENT TO THE EX. 18" RCP.
TO BE RELOCATED.
EXIST 3" PVC FM
NOTE: BASE LEVEL A SUE WAS CONDUCTED
ADJACENT TO THE EX. 18" RCP.
TO BE RELOCATED.
R/W LINE (PER HC
INVENTORY MAP)
16.3'
15'
R/W LINE (PER HC
INVENTORY MAP)
S-1
S-2
MHWL = 0.52'
W E
TL
AN
D B
OU
N D
AR
Y
W E
TL
AN
D B
OU
N D
AR
Y
1.5' THICK DITCH LINING
CLEAN RUBBLE RIPRAP PER
FDOT SPECIFICATION 530.
RELOCATE 2" PVC WM AT PIPE
INVERT ELEVATION -1.85'.
RELOCATE 3" PVC FM AT PIPE
INVERT ELEVATION -2.66'.
℄ OF CONST.
1.5' 1.5'
0.4'
1'
PROP. PIPE END GUARD/MANATEE GRATE-FIXED,
NON-HINGED (SEE DETAIL SHEET 14)
MHWL = 0.52'
PROP. PIPE END GUARD/MANATEE GRATE-FIXED,
NON-HINGED (SEE DETAIL SHEET 14)
1' THICK BEDDING STONE PER FDOT
SPECIFICATION 530.
1.5' THICK DITCH LINING
CLEAN RUBBLE RIPRAP PER
FDOT SPECIFICATION 530.
1' THICK BEDDING STONE PER FDOT
SPECIFICATION 530.
EXIST. UG CATV
SPECTRUM
APPROXIMATELY 1.5' TO 2' DEEP
APPROXIMATE LOCATION OF PROP. UG CATV SPECTRUM
NOTE: TO BE ADJUSTED BY SPECTRUM PRIOR TO THE
START OF CONSTRUCTION
EXIST. 1-1/2" W/FOC
FRONTIER
NOTE: TO BE ADJUSTED BY FRONTIER
PRIOR TO THE START OF CONSTRUCTION
EXIST. UG CATV
SPECTRUM
PROP. UG CATV
SPECTRUM
NOTE:
THE CROSS SECTIONS STATIONING ARE BASED ON
THE LOCATION AT CULVERT CROSSING AT SURVEY
BASELINE
ADJUST 1-1/2" W/ FOC FOR S-3
APPOX DEPTH 48"/52" BORED
FRONTIER
STA. 10+98.76 (36.0' LT.)
EXIST INLET S-1A
S-3
THE FOLLOWING NARRATIVE OF THE STORMWATER
POLLUTION PREVENTION PLAN CONTAINS REFERENCES TO
THE STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE
CONSTRUCTION, THE DESIGN STANDARDS, AND OTHER
SHEETS OF THESE CONSTRUCTION PLANS. THE FIRST
SHEET OF THE CONSTRUCTION PLANS (CALLED THE KEY
SHEET) CONTAINS AN INDEX TO THE OTHER SHEETS. THE
COMPLETE STORMWATER POLLUTION PREVENTION PLAN
INCLUDES SEVERAL ITEMS: THIS NARRATIVE DESCRIPTION,
THE DOCUMENTS REFERENCED IN THIS NARRATIVE, THE
CONTRACTOR'S APPROVED EROSION CONTROL PLAN
REQUIRED BY SPECIFICATION SECTION 104, AND REPORTS
OF INSPECTIONS MADE DURING CONSTRUCTION.
1.0 SITE DESCRIPTION:
1.A. NATURE OF CONSTRUCTION ACTIVITY:
THE PROJECT IS THE REPLACEMENT AND RENEWAL OF
EXISTING CULVERT CROSSING UNDER 1ST AVE NW. THIS
INVOLVES CONSTRUCTING ROADWAY SURFACE,
UNDERGROUND STORM DRAIN AND CROSS DRAIN SYSTEMS,
AND EROSION PROTECTION. THE PROJECT IMPACTS 1ST AVE
NW LOCATED BETWEEN 2ND ST NW AND S TAMIAMI TRAIL,
A DISTANCE OF APPROXIMATELY 0.028 MILES.
1.B. SEQUENCE OF MAJOR SOIL DISTURBING ACTIVITIES:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE
CONTRACTOR SHALL PROVIDE A DETAILED SEQUENCE OF
CONSTRUCTION FOR ALL CONSTRUCTION ACTIVITIES. THE
CONTRACTOR SHALL FOLLOW THE SEQUENCE OF MAJOR
ACTIVITIES DESCRIBED BELOW, UNLESS THE CONTRACTOR
PROPOSES A DIFFERENT SEQUENCE THAT IS EQUAL OR
BETTER AT CONTROLLING EROSION AND TRAPPING
SEDIMENT AND IS APPROVED BY THE ENGINEER.
FOR EACH CONSTRUCTION PHASE, INSTALL PERIMETER
CONTROLS AFTER CLEARING AND GRUBBING NECESSARY FOR
INSTALLATION OF CONTROLS BUT BEFORE BEGINNING OTHER
WORK FOR THE CONSTRUCTION PHASE. REMOVE PERIMETER
CONTROLS ONLY AFTER ALL UPSTREAM AREAS ARE
STABILIZED.
1. CLEARING AND GRUBBING, EARTHWORK, AND
STORM DRAIN CONSTRUCTION FOR THE UNDERGROUND
STORM DRAIN SYSTEMS.
2. STORM DRAIN AND ROADWAY UNDERDRAIN
CONSTRUCTION. CONSTRUCT THE STORM DRAIN PIPE IN
THE UPSTREAM DIRECTION.
3. EARTHWORK ASSOCIATED WITH THE
CONSTRUCTION OF ROADWAY, SUBGRADE, BASE, AND
PAVEMENT.
AREA ESTIMATES:
TOTAL SITE AREA: 0.25 ACRES
TOTAL AREA TO BE DISTURBED: 0.16 ACRES
1.C SOILS DATA: NO GEOTECHNICAL
INVESTIGATION WAS CONDUCTED FOR THIS
PROJECT. SOILS INFORMATION FROM NRCS
INDICATE THAT THE SOILS WITHIN THE PROJECT
IS COMPOSED OF WABASSO SOIL (SANDY AND
LOAMY).
1.D OUTFALL/DISCHARGE INFORMATION:
THE PROJECT OUTFALLS TO RUSKIN INLET.
LOCATION: LATITUDE 27° 43' 11.6” N,
LONGITUDE, 82° 26' 06.5” W.
EST. DRAINAGE AREA SIZE: 5.33 ACRES
(OVERLAND RUNOFF TO EXIST INLETS)
RECEIVING WATER NAME: RUSKIN INLET
1.E SITE MAP:
THE CONSTRUCTION PLANS ARE BEING USED AS
THE SITE MAPS. THE LOCATION OF THE
REQUIRED INFORMATION IS DESCRIBED BELOW.
THE SHEET NUMBERS FOR THE PLAN SHEETS
REFERENCED ARE IDENTIFIED ON THE KEY SHEET
OF THESE CONSTRUCTION PLANS.
* DRAINAGE PATTERNS: THE DRAINAGE
BASIN DIVIDES AND FLOW DIRECTIONS ARE
SHOWN ON THE DRAINAGE MAPS. THE ARROWS
ABOVE AND BELOW THE PROFILE REPRESENT THE
FLOW DIRECTION AT THE LEFT AND RIGHT
PROPERTY LINE, RESPECTIVELY. ARROWS
POINTING TO THE PROFILE INDICATE RUNOFF
COMING TO THE SITE. POINTING AWAY FROM
THE SITE INDICATE RUNOFF LEAVING THE SITE.
*APPROXIMATE SLOPES: THE SLOPES OF THE
SITE CAN BE SEEN IN THE CROSS SECTION
SHEETS AND THE PLAN-PROFILE SHEETS.
*AREAS OF SOIL DISTURBANCE: THE AREAS TO
BE DISTURBED ARE INDICATED ON THE
PLAN-PROFILE SHEETS AND THE CROSS SECTION
SHEETS. ANY AREAS WHERE PERMANENT
FEATURES ARE SHOWN TO BE CONSTRUCTED
ABOVE OR BELOW GROUND WILL BE DISTURBED.
*AREAS NOT TO BE DISTURBED: ESSENTIALLY
THE WHOLE PROJECT WILL BE DISTURBED DURING
CONSTRUCTION.
*LOCATIONS OF TEMPORARY CONTROLS:
THESE ARE SHOWN ON THE EROSION CONTROL
PLAN. TABLES PROVIDING SUMMARIES OF
TEMPORARY EROSION AND SEDIMENT CONTROL
ITEMS ARE PROVIDED IN THE SUMMARY OF
QUANTITY SHEETS.
* AREAS TO BE STABILIZED: TEMPORARY
STABILIZATION PRACTICES ARE SHOWN IN THE
SAME LOCATION AS THE TEMPORARY CONTROLS
MENTIONED ABOVE. PERMANENT STABILIZATION
IS SHOWN ON THE TYPICAL SECTION SHEETS,
THE PLAN-PROFILE SHEETS.
* SURFACE WATERS: OTHER SURFACE
WATERS ARE LOCATED WITHIN THE SITE. THESE
AREAS INCLUDE THE ROADSIDE SWALES. THIS IS
LOCATED ON THE PLAN AND PROFILE SHEETS.
* DISCHARGE POINTS TO SURFACE
WATERS: THE PIPE CULVERTS DISCHARGES
TOWARDS THE NORTHEAST AS SHOWN ON THE
DRAINAGE MAP AND PLAN AND PROFILE SHEET.
1.F RECEIVING WATERS:
SEE ITEM 1.D. FOR THE OUTFALL LOCATIONS AND
RECEIVING WATER NAMES. THE UNAMED
TRIBUTARY MAY BE CONSIDERED AS
WETLANDS/OTHER SURFACE WATER.
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS SHT. NO.
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\9 STORMWATER POLLUTION PREVENTION PLAN.dwgLaTorre, Haylee 7/11/2025 10:59:31 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
STORMWATER POLLUTION
PREVENTION PLAN
2.0 CONTROLS:
2.A. EROSION AND SEDIMENT CONTROLS:
IN THE SEDIMENT AND EROSION CONTROL PLAN,
THE CONTRACTOR SHALL DESCRIBE THE
PROPOSED STABILIZATION AND STRUCTURAL
PRACTICES BASED ON THE CONTRACTOR'S
PROPOSED TEMPORARY TRAFFIC CONTROL (TTC)
PLAN. THE FOLLOWING RECOMMENDED
GUIDELINES ARE BASED ON THE TEMPORARY
TRAFFIC CONTROL PLAN OUTLINED IN THE
CONSTRUCTION PLANS. WHERE FOLLOWING THE
TEMPORARY TRAFFIC CONTROL PLAN OUTLINED IN
THESE CONSTRUCTION PLANS, THE CONTRACTOR
MAY CHOSE TO ACCEPT THE FOLLOWING
GUIDELINES OR MODIFY THEM IN THE SEDIMENT
AND EROSION CONTROL PLAN, SUBJECT TO
APPROVAL BY THE ENGINEER. AS WORK
PROGRESSES, THE CONTRACTOR SHALL MODIFY
THE PLAN TO ADAPT TO SEASONAL VARIATION,
CHANGES IN CONSTRUCTION ACTIVITIES, AND
THE NEED FOR BETTER PRACTICES.
FOR EACH CONSTRUCTION PHASE, INSTALL
PERIMETER CONTROLS AFTER CLEARING AND
GRUBBING NECESSARY FOR INSTALLATION OF
CONTROLS BUT BEFORE BEGINNING OTHER WORK
FOR THE CONSTRUCTION PHASE. REMOVE
PERIMETER CONTROLS ONLY AFTER ALL UPSTREAM
AREAS ARE STABILIZED.
TEMPORARY TRAFFIC CONTROL PLANS:
1ST AVE NW, STATION 10+00 TO 11+45.34
ROADWAY CLOSURE - MAINTAIN LOCAL TRAFFIC
ACCESS FOR RESIDENTS LOCATED NORTHWEST
OF THE PROJECT SITE TO THE 1ST AVE NW
DEADEND AND RESIDENTS LOCATED ON
DAGWOOD WAY.
2.A.1 STABILIZATION PRACTICES:
IN THE SEDIMENT AND EROSION CONTROL PLAN,
THE CONTRACTOR SHALL DESCRIBE THE
STABILIZATION PRACTICES PROPOSED TO
CONTROL EROSION. THE CONTRACTOR SHALL
INITIATE ALL STABILIZATION MEASURES AS SOON
AS PRACTICAL, BUT IN NO CASE MORE THAN 7
DAYS, IN PORTIONS OF THE SITE WHERE
CONSTRUCTION ACTIVITIES HAVE TEMPORARILY
OR PERMANENTLY CEASED. THE STABILIZATION
PRACTICES SHALL INCLUDE AT LEAST THE
FOLLOWING, UNLESS OTHERWISE APPROVED BY
THE ENGINEER.
TEMPORARY:
* ARTIFICIAL COVERINGS IN ACCORDANCE
WITH SPECIFICATION SECTION 104.
* TURF AND SOD IN ACCORDANCE WITH
SPECIFICATION SECTION 104.
PERMANENT:
* ASPHALT OR CONCRETE SURFACE.
* SOD IN ACCORDANCE WITH
SPECIFICATION SECTION 570.
2.A.2 STRUCTURAL PRACTICES:
IN THE SEDIMENT AND EROSION CONTROL PLAN,
THE CONTRACTOR SHALL DESCRIBE THE
PROPOSED STRUCTURAL PRACTICES TO CONTROL
OR TRAP SEDIMENT AND OTHERWISE PREVENT
THE DISCHARGE OF POLLUTANTS FROM EXPOSED
AREAS OF THE SITE. SEDIMENT CONTROLS SHALL
BE IN PLACE BEFORE DISTURBING SOIL UPSTREAM
OF THE CONTROL. THE STRUCTURAL PRACTICES
SHALL INCLUDE AT LEAST THE FOLLOWING,
UNLESS OTHERWISE APPROVED BY THE ENGINEER:
TEMPORARY:
* SEDIMENT BARRIERS AND FLOATING
TURBIDITY BARRIERS IN ACCORDANCE WITH
DESIGN STANDARD 102 AND SPECIFICATION
SECTION 104.
* INLET PROTECTION IN ACCORDANCE
WITH DESIGN STANDARD 102 AND SPECIAL
DETAILS SHOWN IN THE TTC PLAN.
PERMANENT:
* SOD.
2.B STORMWATER MANAGEMENT:
TEMPORARY PUMPING BYPASS WILL BE UTILIZED
AS NEEDED DURING INSTALLATION OF THE
CULVERT SYSTEM. BEST MANAGEMENT PRACTICES
WILL BE UTILIZED TO MINIMIZE DOWNSTREAM
EROSION AND POLLUTION.
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS SHT. NO.
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\9 STORMWATER POLLUTION PREVENTION PLAN.dwgLaTorre, Haylee 7/11/2025 10:59:31 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
STORMWATER POLLUTION
PREVENTION PLAN
TH
TH
TH
TH
B
eg. S
TA. 10+00.00
E nd S
TA. 11+45.34
2.C OTHER CONTROLS:
2.C.1 WASTE DISPOSAL:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL
DESCRIBE THE PROPOSED METHODS TO PREVENT THE DISCHARGE OF SOLID
MATERIALS, INCLUDING BUILDING MATERIALS, TO WATERS OF THE UNITED
STATES. THE PROPOSED METHODS SHALL INCLUDE AT LEAST THE
FOLLOWING, UNLESS OTHERWISE APPROVED BY THE ENGINEER:
* PROVIDING LITTER CONTROL AND COLLECTION WITHIN THE
PROJECT DURING CONSTRUCTION ACTIVITIES.
* DISPOSING OF ALL FERTILIZER OR OTHER CHEMICAL CONTAINERS
ACCORDING TO EPA'S STANDARD PRACTICES AS DETAILED BY THE
MANUFACTURER.
* DISPOSING OF SOLID MATERIALS INCLUDING BUILDING AND
CONSTRUCTION MATERIALS OFF THE PROJECT SITE BUT NOT IN SURFACE
WATERS, OR WETLANDS.
2.C.2 OFF-SITE VEHICLE TRACKING & DUST CONTROL:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL
DESCRIBE THE PROPOSED METHODS FOR MINIMIZING OFFSITE VEHICLE
TRACKING OF SEDIMENTS AND GENERATING DUST. THE PROPOSED
METHODS SHALL INCLUDE AT LEAST THE FOLLOWING, UNLESS OTHERWISE
APPROVED BY THE ENGINEER.
* COVERING LOADED HAUL TRUCKS WITH TARPAULINS.
* REMOVING EXCESS DIRT FROM ROADS DAILY.
* STABILIZING CONSTRUCTION ENTRANCES ACCORDING TO DESIGN
STANDARD 106.
* USING ROADWAY SWEEPERS DURING DUST GENERATING ACTIVITIES
SUCH AS EXCAVATION AND MILLING OPERATIONS.
2.C.3 STATE AND LOCAL REGULATIONS FOR WASTE DISPOSAL, SANITARY
SEWER, OR SEPTIC TANK REGULATIONS:
IN THE SECTION 104 EROSION CONTROL PLAN, THE CONTRACTOR SHALL
DESCRIBE THE PROPOSED PROCEDURES TO COMPLY WITH APPLICABLE
STATE AND LOCAL REGULATIONS FOR WASTE DISPOSAL, AND SANITARY
SEWER OR SEPTIC SYSTEMS.
2.C.4 FERTILIZERS AND PESTICIDES:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL
DESCRIBE THE PROCEDURES FOR APPLYING FERTILIZERS AND PESTICIDES.
THE PROPOSED PROCEDURES SHALL COMPLY WITH HILLSBOROUGH COUNTY
ORDINANCE 21-42, REGULATION OF THE USE OF FERTILIZERS CONTAINING
NITROGEN AND PHOSPHOROUS.
2.C.5 TOXIC SUBSTANCES:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL
PROVIDE A LIST OF TOXIC SUBSTANCES THAT ARE LIKELY TO BE USED ON
THE JOB AND PROVIDE A PLAN ADDRESSING THE GENERATION,
APPLICATION, MIGRATION, STORAGE, AND DISPOSAL OF THESE SUBSTANCES.
2.D.4 APPROVED STATE AND LOCAL PLANS AND PERMITS:
* FDEP RULE CHAPTER 62-25 F.A.C.
* RULES OF THE ENVIRONMENTAL PROTECTION COMMISSION OF
HILLSBOROUGH COUNTY CHAPTER 1-11 WETLANDS.
3.0 MAINTENANCE:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL
PROVIDE A PLAN FOR MAINTAINING ALL EROSION AND SEDIMENT CONTROLS
THROUGHOUT CONSTRUCTION. THE MAINTENANCE PLAN SHALL AT A
MINIMUM, COMPLY WITH THE FOLLOWING:
* SILT FENCE: MAINTAIN PER SECTION 104. THE CONTRACTOR
SHOULD ANTICIPATE REPLACING SILT FENCE ON 12 MONTH INTERVALS.
* SEDIMENT BARRIERS: REMOVE SEDIMENT AS PER MANUFACTURER'S
RECOMMENDATIONS OR WHEN WATER PONDS IN UNACCEPTABLE AMOUNTS
OR AREAS.
4.0 INSPECTIONS:
QUALIFIED PERSONNEL SHALL INSPECT THE FOLLOWING ITEMS AT LEAST
ONCE EVERY SEVEN CALENDAR DAYS AND WITHIN 24 HOURS OF THE END
OF A STORM THAT IS 0.50 INCHES OR GREATER. TO COMPLY, THE
CONTRACTOR SHALL INSTALL AND MAINTAIN RAIN GAUGES AND RECORD THE
DAILY RAINFALL. WHERE SITES HAVE BEEN PERMANENTLY STABILIZED,
INSPECTIONS SHALL BE CONDUCTED AT LEAST ONCE EVERY MONTH. THE
CONTRACTOR SHALL ALSO INSPECT THAT CONTROLS INSTALLED IN THE
FIELD AGREE WITH THE LATEST STORMWATER POLLUTION PREVENTION
PLAN.
* POINTS OF DISCHARGE TO WATERS OF THE UNITED STATES.
* POINTS OF DISCHARGE TO MUNICIPAL SEPARATE STORM DRAIN
SYSTEMS.
* DISTURBED AREAS OF THE SITE THAT HAVE NOT BEEN FINALLY
STABILIZED.
* AREAS USED FOR STORAGE OF MATERIALS THAT ARE EXPOSED TO
PRECIPITATION.
* STRUCTURAL CONTROLS.
* STORMWATER MANAGEMENT SYSTEMS.
* LOCATIONS WHERE VEHICLES ENTER OR EXIT THE SITE.
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS SHT. NO.
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
STORMWATER POLLUTION
PREVENTION PLAN
THE CONTRACTOR SHALL INITIATE REPAIRS WITHIN 24 HOURS OF
INSPECTIONS THAT INDICATE ITEMS ARE NOT IN GOOD WORKING ORDER.
IF INSPECTIONS INDICATE THAT THE INSTALLED STABILIZATION AND
STRUCTURAL PRACTICES ARE NOT SUFFICIENT TO MINIMIZE EROSION,
RETAIN SEDIMENT, AND PREVENT DISCHARGING POLLUTANTS, THE
CONTRACTOR SHALL PROVIDE ADDITIONAL MEASURES, AS APPROVED BY THE
ENGINEER.
5.0 NON-STORMWATER DISCHARGES:
IN THE SECTION 104 EROSION CONTROL PLAN, THE CONTRACTOR SHALL
IDENTIFY ALL ANTICIPATED NON-STORMWATER DISCHARGES (EXCEPT FLOWS
FROM FIRE FIGHTING ACTIVITIES). THE CONTRACTOR SHALL DESCRIBE THE
PROPOSED MEASURES TO PREVENT POLLUTION OF THESE NON-STORMWATER
DISCHARGES. IF THE CONTRACTOR ENCOUNTERS CONTAMINATED SOIL OR
GROUNDWATER, CONTACT THE ENGINEER AND HILLSBOROUGH COUNTY.
N
1"
EROSION CONTROL PLAN
INSTALL 80 LF SILT FENCE
INSTALL 80 LF SILT FENCE
INSTALL 40 LF
SILT FENCE
INSTALL 180 LF SILT FENCE
IN COMPLIANCE TO EPC MINOR WORK PERMIT, THE CONTRACTOR SHALL
PROVIDE THE METHOD OF DREDGING TO BE USED INCLUDING DETAILS SUCH AS
EQUIPMENT SIZE, AMOUNT TO BE DREDGED, HOURS OF OPERATION, METHOD OF
TRANSPORT, MATERIAL TRANSFER METHODS, TRANSPORTATION AND ACCESS
ROUTES, UPLAND DISPOSAL AREA LOCATION, DIMENSIONS OF SPOIL DISPOSAL
BERMS, DISPOSAL METHODS, FINAL DISPOSAL LOCATION OR DISPOSAL
CONTRACTOR INFORMATION.
THE CONTRACTOR SHALL UTILIZE AERATION TANKS OR BASINS, AIR STRIPPERS,
WET SCRUBBERS, INCINERATORS, CAUSTICS OR MASKING AGENTS, OR ANY OTHER
CONTROL PROCEDURES OR TECHNOLOGIES.
CONTROL POINT
N: 1231095.85 E: 515406.48
ELEV: 2.88
LANDMARK 2000
CONTROL POINT
N: 1231099.55 E: 515274.95
ELEV: 2.96
CAPPED IRON ROD SET (LB 5122)
2.8 2.1
1.2 1.9
3.0
2.78 3.09
2.88 3.1
2.7
2.7
INV 12" RCP
ELEV= 1.03
INV 12" RCP
ELEV= 1.25
INV 18" RCP
ELEV= 0.25
2.94
2.95
3.34
2.8 2.5
1.0
2.3 2.6
2.7
0.6
1.2
2.3
3.4 3.6
3.45 3.41 3.04
3.1 3.2 3.2
T
2.94 2.83
3.00
2.9 3.4
3.25 3.28
2.64
2.8
2.5
2.4
TOP ELEV=2.79
INV 18" RCP
ELEV= 0.30
3.19 3.02
3.2 3.0
2.5
INV 18" RCP
ELEV= -0.97
2.1
INV 15" ADS
ELEV= -0.02
V V
INV 18" RCP
ELEV= 0.20
INV 18" RCP
ELEV= 0.28
1 ST AVENUE NW
CARLYLE BLVD (P)
(ASPHALT)
ST
S
TR
EE
T
N W
3R D
ST
RE
ET
(P
(A
SP
HA
LT
LOT 194
FOLIO No. 055866-0000
PORTIONS OF LOTS 87
THROUGH 90, INCLUSIVE
FOLIO No. 055803-0000
FOLIO No. 056240-0000
MAP OF RUSKIN CITY IN HILLSBOROUGH COUNTY, FLORIDA
PLAT BOOK 5, PAGE 75
8" CONCRETE
HEADWALL
NOTE:
CONFLICTING PIPE SIZES AND
MATERIALS WERE CONFIRMED.
TH
TH
TH
TH
TH-4
TH-1
TH-2
TH-3
B
eg. S
TA. 10+00.00
E nd S
TA. 11+45.34
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS SHT. NO.
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\12 TEMPORARY TRAFFIC CONTROL PLANS.dwgLaTorre, Haylee 7/11/2025 11:01:44 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
N
1"
TEMPORARY TRAFFIC CONTROL
PLANS
EOP (TYP.)
TEMPORARY TRAFFIC CONTROL NOTES:
1. MAINTENANCE OF TRAFFIC MUST BE IN ACCORDANCE WITH HILLSBOROUGH COUNTY PUBLIC WORKS STANDARD SPECIFICATIONS, SECTION 01500 MAINTENANCE OF TRAFFIC. USE THE FOLLOWING INFORMATION IN DEVELOPING A
MAINTENANCE OF TRAFFIC PLAN:
· THE REGULATORY SPEED MUST REMAIN THE SAME AS THE EXISTING POSTED SPEED LIMIT.
· WORK ZONE SPEED LIMIT = 25 MPH
· PROVIDE PORTABLE CHANGEABLE MESSAGE SIGNS (PCMS) ONE WEEK IN ADVANCE NOTIFYING THE START OF
CONSTRUCTION DATE.
· ROAD CLOSURE RESTRICTIONS WILL BE ALLOWED BETWEEN THE HOURS 8:00 AM TO 6:00 PM.
· UTILIZE STANDARD PLAN INDEXES 102-600, 102-601, 102-602, AND 102-603 IN DEVELOPING THE
MAINTENANCE OF TRAFFIC PLAN.
2. NOTIFY ADJACENT PROPERTY OWNERS 48 HOURS IN ADVANCE OF CONSTRUCTION ACTIVITIES WHICH SHALL
RESTRICT ACCESS, DELIVERY, ETC., TO PRIVATE OR COMMERCIAL PROPERTIES.
3. MAINTAIN PEDESTRIAN CROSSING ACCESS PER FDOT DESIGN STANDARD INDEXES AND AMERICAN DISABILITIES ACT ACCOMMODATION GUIDE REQUIREMENTS AT ALL TIMES. IT MAY BE NECESSARY TO ESTABLISH A TEMPORARY CROSSING IN ACCORDANCE WITH THE SPECIFICATIONS IN ORDER TO PROVIDE SAFE PASSAGE FOR PEDESTRIANS.
TWO-LANE, WORK ON SHOULDER
FDOT SP INDEX 102-602 (TYP.)
1ST AV
E NW
1S T
S T
N W
LANE CLOSURE USING FLAGGERS
FDOT SP INDEXES 102-603 AND 102-625
TWO-LANE ROADWAY, WORK BEYOND THE SHOULDER
FDOT SP INDEX 102-601 (TYP.)
S-1A
S-1
S-2
S-3
BEGIN PROJECT
STA. 10+00.00
END PROJECT
STA. 11+45.34
℄ OF CONST.S-#
LEGEND
LANE CLOSURE
EXIST. STRUCTURE ID NO.
EXIST. STRUCTURE ID NO.
S-#
S-#
1ST AVE NW AT 1ST ST SW CRRP RECOMMENDED DETOUR ROUTE FOR MOT
1. THE PROPOSED DETOUR ROUTE FOR THE 1ST AVE NW CULVERTS REPLACEMENT ROAD
CLOSURE PROPOSES TO DIRECT LOCAL TRAFFIC TO THE FOLLOWING ROADWAYS:
· 2ND AVE NW
·SHELL POINT RD
·S TAMIAMI TRAIL (US HWY 41)
2. ALL MOT SIGNS ARE TO ADHERE TO FDOT STANDARD PLANS INDEXES 102-600.
3. ALL ADVANCED WARNING SIGNS ARE TO BE POST-MOUNTED.
4. ALL SIGNAGE AND VMBs ARE TO BE PLACED FOR ADVANCED WARNING 2 WEEKS PRIOR
TO ROAD CLOSURE.
5. ROAD CLOSURES ARE NOT TO EXCEED 4 WEEKS.
6. CONTRACTOR SHALL NOTIFY AFFECTED RESIDENTS 48 HOURS PRIOR TO DRIVEWAY
CLOSURE.
7. CONTRACTOR MUST SUBMIT A SIGNED AND SEALED DETOUR PLAN FOR REVIEW WHEN
APPLYING FOR THEIR TTC PERMIT.
1 ST AVENUE NW
CARLYLE BLVD (P)
(ASPHALT)
ST
S
TR
EE
T
N W
3R D
ST
RE
ET
(P
(A
SP
HA
LT
U S
HW
Y
(A
SP
HA
LT
LOT 194
FOLIO No. 055866-0000
PORTIONS OF LOTS 87
THROUGH 90, INCLUSIVE
FOLIO No. 055803-0000
FOLIO No. 056240-0000
MAP OF RUSKIN CITY IN HILLSBOROUGH COUNTY, FLORIDA
PLAT BOOK 5, PAGE 75
8" CONCRETE
HEADWALL
NOTE:
CONFLICTING PIPE SIZES AND
MATERIALS WERE CONFIRMED.
TH
TH
TH
TH
TH-4
TH-1
TH-2
TH-3
B
eg. S
TA. 10+00.00
E nd S
TA. 11+45.34
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS SHT. NO.
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\12-A TEMPORARY TRAFFIC CONTROL PLANS.dwgLaTorre, Haylee 7/11/2025 11:05:41 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
N
1"
TEMPORARY TRAFFIC CONTROL
PLANS
12A
1ST AVE
NW
1ST AVE NW
W SHELL POINT RD
S T
AM
IA
M I
TR
AI
L
S T
AM
IA
M I
TR
AI
L
PCMS READS:
1ST ST NW AND 1ST AVE
NW ARE CLOSED AHEAD
TO THRU TRAFFIC, USE
W SHELL POINT RD
DETOUR DETOUR
ROAD CLOSED
THRU TRAFFIC
TO
ROAD CLOSED
THRU TRAFFIC
TO
ROAD CLOSED
THRU TRAFFIC
TO
LEGEND
ROAD CLOSURE
WORK ZONE SIGN
ROADWAY CLOSURE PLAN
DETOUR
2n d
S T
N W
1s t S T
N W
NOTE:
THE CONTRACTOR MUST SUBMIT A SIGNED
AND SEALED DETOUR PLAN FOR REVIEW
WHEN APPLYING FOR THEIR TTC PERMIT. THE
INCLUDED DETOUR PLANS ONLY SHOW THE
PROPOSED ROUTE.
B
eg. S
TA. 10+00.00
E nd S
TA. 11+45.34
CONTROL POINT
N: 1231095.85 E: 515406.48
ELEV: 2.88
LANDMARK 2000
CONTROL POINT
N: 1231099.55 E: 515274.95
ELEV: 2.96
CAPPED IRON ROD SET (LB 5122)
2.8
2.1
1.2 1.9
3.0 2.78
3.09 2.88
3.1
2.7 2.7
INV 12" RCP
ELEV= 1.03
INV 12" RCP
ELEV= 1.25
INV 18" RCP
ELEV= 0.25
2.94
2.95
3.34
2.8 2.5
1.0
2.3
2.6
2.7
0.6 1.2
2.3
3.4 3.6
3.45 3.41 3.04
3.1 3.2 3.2
T
2.94 2.83
3.00
2.9 3.4
3.25 3.28
2.64
2.8 2.5
2.4
TOP ELEV=2.79
INV 18" RCP
ELEV= 0.30
3.19
3.02
3.2
3.0 2.5
INV 18" RCP
ELEV= -0.97
2.1
INV 15" ADS
ELEV= -0.02
V V
C2-8
C2-7
C2-6 C2-5
C2-4
C2-3 C2-2 C2-1
INV 18" RCP
ELEV= 0.20
INV 18" RCP
ELEV= 0.28
TH
TH
TH
TH
BTV(
D)
BTV(
D)
BTV(
D)
BTV(
D)
BT
V( D)
BTV(D)
BTV(D)
BTV(D)
BTV(D)
BTV(D)
BTV(D)
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BTV
BT
V
BT
V
BT
V
BT
V BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV BTV
BT
BT
BT
BT
BT
BT
BT
BT
BT
B T
B T
B T
B T
B T
B T
B T
B T
B T
B T
B T
B T
BT
BT
BT
BT
BT
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS SHT. NO.
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\13 UTILITY ADJUSTMENTS.dwgLaTorre, Haylee 7/11/2025 11:06:40 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
N
1"
UTILITY ADJUSTMENTS 13
3" FM / TO BE PROTECTED
HCWRD
2" PVC WM /TO BE PROTECTED
HCWRD
UG CATV / TO BE ADJUSTED
SPECTRUM
1-1/2" W/FOC/TO BE ADJUSTED/PROTECTED
FRONTIER
S-1A
S-1
S-2
S-3
NOTES:
LOCATIONS OF ALL UNDERGROUND UTILITIES MAY NOT REFLECT ACTUAL LOCATIONS.
CONTRACTOR IS TO FIELD VERIFY THE PIPE LOCATIONS AND MATERIALS OF ALL
POTENTIAL IMPACTED UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION AND
COORDINATE WITH AFFECTED UAO'S.
2" PVC WM /TO BE ADJUSTED
HCWRD
SEE NOTES ON ROADWAY PLAN SHEET 7
AND CROSS SECTIONS SHEET 8
3" FM / TO BE ADJUSTED
HCWRD
SEE NOTES ON ROADWAY PLAN SHEET 7
AND CROSS SECTIONS SHEET 8
SPECIAL CONSTRUCTION NOTES FOR WORKING NEAR WATER MAINS & FORCEMAINS:
1. NO HEAVY EQUIPMENT IS TO BE PLACED OVER THE EXISTING WATER MAIN OR FORCEMAIN UNTIL THE STABILIZED SUB-GRADE
AND BASE ARE IN PLACE COVERING THESE PIPES.
2. THE ENGINEER-OF-RECORD, OR SOMEONE UNDER THEIR SUPERVISION, IS TO BE ON SITE DURING THE REMOVAL OF THE EXISTING GROUND COVER, AND THE REPLACEMENT OF THE STABILIZED SUB-GRADE AND BASE. SPECIAL ATTENTION IS TO BE
GIVEN TO PREVENTING UNDUE STRESS ON THE EXISTING PIPES.
3. THE CONTRACTOR SHALL CONTACT TERRY SHIFLETT, WATER RESOURCES DEPARTMENT'S SOUTH LINE MAINTENANCE SUPERVISOR@ (813) 298-3960, AT LEAST 1-WEEK IN ADVANCE OF PERFORMING ANY WORK NEAR THE EXISTING WATER MAIN.
4. THE CONTRACTOR SHALL CONTACT BRIAN SLANE, WATER RESOURCES DEPARTMENT'S LOW PRESSURE SANITARY SEWER MAINTENANCE SUPERVISOR@ (813) 612-7714, AT LEAST 1-WEEK IN ADVANCE OF PERFORMING ANY WORK NEAR THE EXISTING
FORCEMAIN.
5. THE CONTRACTOR SHALL CONTACT THE UTILITY COORDINATION TEAM BY EMAIL TO UTILITYCOORDINATION@HCFLGOV.NET AT LEAST 1-WEEK IN ADVANCE OF PERFORMING ANY WORK NEAR THE EXISTING WATER MAIN OR FORCEMAIN.
6. THE CONTRACTOR WILL NEED TO HAVE MATERIALS ON-SITE TO REPAIR EITHER LINE IN THE EVENT OF A BREAK (2-INCH AND 3-INCH PIPE, CLAMPS, SLEEVES, FITTINGS, BLEACH, ETC...) AND THEY MUST CONTACT THE COUNTY IMMEDIATELY AT (813)671-7604.
4-4" CONDUIT 2-W/BT/TO REMAIN
FRONTIER
UG CATV/PROPOSED
SPECTRUM
1-1/2" W/FOC
FRONTIER
PEDESTAL
FRONTIER
1-1/2" W/FOC ADJUST/PROTECT FOR APPROX DEPTH 48"/52" BORED
FRONTIER
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\14 MISCELLANEOUS DETAILS.dwgLaTorre, Haylee 7/11/2025 11:07:06 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
MISCELLANEOUS DETAILS 14
NOTE: CONTRACTOR TO PROTECT AND MAINTAIN EXISTING CONDITIONS OF WETLANDS WITHIN PROJECT LIMITS.
Z:\Shared\Projects\Water\5003\001-13\CAD\Construction\SQ-1 SUMMARY OF QUANTITIES.dwgLaTorre, Haylee 7/11/2025 11:07:14 AM
PLUMMER ASSOCIATES, INC.
2 URBAN CENTRE,
4890 W KENNEDY BLVD, SUITE 985
TAMPA, FL 33609
CAPITAL PROGRAMS DEPARTMENT
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
CIP NO.
46142473
111 1ST AVE NW CULVERT REPLACEMENT
T H E O
F F
IC
IA
L R E C O R D O
F T
H
IS
S
H E E T I S T
H E E
LE
C T R O N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N E D A
N D S
E A
LE
D U
N D E R R
U
LE
1G
-2 .0 4, F
.A .C
SUMMARY OF QUANTITIES SQ-1
| Sheets and Views |
| 1 KEY SHEET |
| 2 SIGNATURE SHEET |
| 3 SUMMARY OF PAY ITEMS |
| 4 DRAINAGE MAP |
| 5 TYPICAL SECTION |
| 6 GENERAL NOTES |
| 7 ROADWAY PLAN |
| 8 CROSS SECTIONS |
| 9 STORMWATER POLLUTION PREVENTION PLAN |
| 10 STORMWATER POLLUTION PREVENTION PLAN |
| 11 STORMWATER POLLUTION PREVENTION PLAN |
| 12 TEMPORARY TRAFFIC CONTROL PLANS |
| 12A TEMPORARY TRAFFIC CONTROL PLANS |
| 13 UTILITY ADJUSTMENTS |
| 14 MISCELLANEOUS DETAILS |
| SQ-1 SUMMARY OF QUANTITIES |
| 2025-07-11T11:09:12-0400 | |
| Haylee C LaTorre |
File details come from the government source that posted it. Updated .