4. E1.0 - FP Demo - 12.24.24.pdf

PDF 234 KB Posted

Attached to
ITB-2425-111 Rex Putnam High School Chiller Replacement Project
Solicitation number
S-P03012-00012402
Issued by
Clackamas County, Oregon

About this file

This is an electrical demolition floor plan drawing (sheet E1.0) for what appears to be a school or athletic facility renovation project. The drawing shows a partial floor plan at 1/4"=1'-0" scale depicting several rooms including a Team Room (G26), Coaches Room (G25), Boiler Room (G31), and Storage Room (G32). The plan details electrical demolition work focused on HVAC-related electrical systems.

The drawing indicates the removal of existing chiller feeders and shows the locations of various mechanical equipment including boilers, heat exchangers, pumps (HWP-1, HWP-2, CHWP-1), and associated electrical components such as motor starters and VFDs (Variable Frequency Drives). There is an outdoor chiller courtyard shown and a mezzanine level where some electrical equipment is located. The drawing provides detailed technical information for contractors to understand the scope of electrical demolition work required in these mechanical spaces.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEMOLITION SCOPE OF WORK:

SCOPE: THE SCOPE OF WORK INCLUDES THE REMOVAL OF

THE EXISTING CHILLER AND SELECTED PUMPS. THE WORK

WILL INCLUDE BUT NOT BE LIMITED TO DEMOLITION (SEE

BELOW) OF THE POWER, AND MECHANICAL EQUIPMENT

INCLUDING BUT NOT BE LIMITED TO CONDUIT, CONDUCTORS,

JUNCTION BOXES AND SUPPORTS. THE DEMOLITION OF

MECHANICAL EQUIPMENT WILL BE BY OTHERS, THE

ELECTRICAL CONTRACTOR WILL DISCONNECT THE

EQUIPMENT PRIOR TO REMOVAL.

DEMOLITION: ELECTRICAL DRAWINGS ARE DIAGRAMMATIC,

DEMOLITION INFORMATION HAS BEEN LISTED ON THE

CONSTRUCTION DRAWINGS, IN THE SPECIFICATIONS OR

INDICATED BELOW. ELECTRICAL DEVICES AND EQUIPMENT

ARE FROM PICTURES, EXISTING RECORD DRAWINGS AND / OR

SITE OBSERVATIONS. THEIR ACCURACY IS NOT GUARANTEED.

IT SHALL BE THE ELECTRICAL CONTRACTORS RESPONSIBILITY

TO VISIT THE SITE PRIOR TO BID AND VERIFY ALL EXISTING

CONDITIONS AND INCLUDE ALL LABOR AND MATERIAL

REQUIRED FOR THE WORK INDICATED IN THE CONSTRUCTION

SET.

THE PURPOSE OF THE DEMOLITION INFORMATION IS TO

OUTLINE A GENERAL DIRECTION OF WHAT NEEDS TO BE

REMOVED TO ACCOMPLISH THE RENOVATION WORK. THE

WORK IS DIAGRAMMATIC IN NATURE AND IS NOT INTENDED TO

BE ALL INCLUSIVE. THE CONTRACTOR IS RESPONSIBLE TO

VERIFY EXISTING CONDITIONS AT THE SITE AND INCLUDE ALL

WORK EVIDENT BY SITE INSPECTION WHETHER OR NOT

SHOWN ON THE DRAWINGS, TO ACHIEVE THE DESIRED

RESULTS INDICATED ON THE DOCUMENTS FOR THE FINISHED

SPACES.

POWER - EXISTING POWER DEVICES WILL BE REMOVED

UNLESS NOTED OTHERWISE ON DRAWINGS. REMOVE DEVICES

AND ASSOCIATED CIRCUITING INCLUDING BUT NOT BE

LIMITED TO CONDUIT, CONDUCTORS, AND SUPPORTS BACK TO

PANEL.

MECHANICAL - SEE MECHANICAL DRAWINGS FOR DEMOLITION

OF EXISTING MECHANICAL EQUIPMENT.

MECHANICAL DEMOLITION - ELECTRICAL CONTRACTOR WILL

DISCONNECT THE POWER AND ASSOCIATED CIRCUITING

INCLUDING BUT NOT BE LIMITED TO CONDUIT, CONDUCTORS,

AND SUPPORTS BACK TO PANEL

TEAM ROOM

G26

COACHES

G25

BOILER

ROOM

G31

STORAGE

G32

1/4"=1'-0"

PARTIAL FLOOR PLAN - ELECTRICAL - DEMO1

E1.0

EECC

HEAT EXCHANGER /

BOILER-1

BOILER-2

HW STORAGE TANK

OUTDOOR

CHILLER

COURTYARD

EXISTING

CHILLER

HWP-1

CHWP-1

HWP-2

C-A

X

C-B

E

LINE OF MEZZANINE

SD-EN

E

4EN

E

V F

D

MOTOR STARTER -

CHWP-1 (P-13)

VFD - HWP-2

SMALL PUMP

MOTOR STARTER -

HWP-1 (P-12)

X

X

X

F

F X

X

(P-13)

(SMALL PUMP)

(P-12)

X

REMOVE EXISTING

CHILLER FEEDERS

DS

DS

DSDS

X

X

X

X

LINE OF MEZZANINE

2-EC

E

N O

R T

H

REMOVE EXISTING

CHILLER FEEDERS

ELECTRICAL EQUIPMENT

LOCATED ON MEZZANINE

REVISIONS:

ISSUE DATE:

SDC JOB #:

DESIGNED BY:

CHECKED BY:

DRAWN BY:

SET TYPE:

R

EX

P U

TN

A

M H

IG

H

S C

H O

O L

C H

IL

LE

R R

EP

LA

C

EM

EN

T

N O

R

TH

C

LA

C K

A M

A S

SC

H

O O

L D

IS

T.

S E

R O

ET

H

E R

D M

IL

W

A U

K

IE

, O R

EG

O

N

SYSTEM DESIGN CONSULTANTS INC.

333 SE SECOND AVE

SUITE 100

PORTLAND OR

97214

503-248-0227

NCS2401

12/24/2024

O EH

18197

OREGON

C.ED 5991,6

ENGI REEN

N F R A GRKN

LA

NOISSEFORPDE

R

RETSIGE

EXPIRES 12/31/26

O RJ S

E1.0

JFR

FLOOR PLAN -

ELECTRICAL

JJD

JJD

CONTACT: JEFFREY DAVIS

File details come from the government source that posted it. Updated .