4-250523 ESTF Structural Plans.pdf
PDF 1 MB Posted
- Solicitation number
- US.251947
- Issued by
- Somerset County, Pennsylvania
About this file
Summary of ESTF Structural Plans
This file comprises structural plans for the Schuylkill County Emergency Training Facility construction project in Pennsylvania, which will be procured through sealed competitive bidding managed by the Schuylkill County Controller. The project is divided into four separate prime contracts: General Construction, Plumbing Construction, HVAC Construction, and Electrical Construction. Sealed bids will be received online via the PennBid Program until Wednesday, October 21, 2026, at 9:00 AM, with bid results posted online following the Board of Commissioners meeting. The tentative award date is Wednesday, October 28, 2026. All bidding documents are available at no cost through the PennBid portal at http://PennBid.bonfirehub.com. Bidders requiring assistance with the PennBid platform may contact support via email at info@pennbid.net or by phone at 610-693-4769.
Each bid submission must include a certified check, bank draft, or satisfactory Bid Bond payable to Schuylkill County in the amount of 10 percent of the total bid; money orders are not acceptable. The successful bidder will be required to provide Performance and Payment Bonds each equal to 100 percent of the contract price with a corporate surety approved by the county. Davis-Bacon wage rates apply to all contracts. Non-discrimination requirements prohibit discrimination based on race, age, color, religion, sex, national origin, or disability. The county reserves the right to waive informalities or reject any or all bids in its best interest.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONCRETE
GENERAL NOTES
DESIGN LOADS
2018 INTERNATIONAL BUILDING CODE
LIVE LOADS
ROOF LIVE LOAD = 20 PSF
FLOOR LIVE LOADS
SLAB ON GRADE TYPICAL DESIGN LOAD
8" SLAB (GARAGE)
MAXIMUM AXLE REACTION = 15,600 LB
SNOW LOADS
GROUND SNOW LOAD = 40 PSF
FLAT ROOF SNOW LOAD, Pf = 44 PSF
SNOW EXPOSURE FACTOR, Ce = 1.0
SNOW LOAD IMPORTANCE FACTOR, Is = 1.2
THERMAL FACTOR, Ct
WIND LOADS
Vult = 125 MPH
RISK CATEGORY = IV
INTERNAL PRESSURE COEFFICIENT = ± 0.18
EXPOSURE CATEGORY = C
SEISMIC
RISK CATEGORY = IV
IMPORTANCE FACTOR, Ie = 1.50
MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS
SS = 0.150 g
S1 = 0.041 g
SITE CLASS = D
DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS
SDS = 0.240 g
SD1 = 0.098 g
SEISMIC RESPONSE MODIFICATION FACTOR, R = 3 (STEEL SYSTEM NOT SPECIFICALLY
DETAILED FOR SEISMIC RESISTANCE)
DESIGN BASE SHEAR = 7.92 KIPS
SEISMIC RESPONSE COEFFICIENT, CS = 0.08
ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE
SEISMIC DESIGN CATEGORY = B
STRUCTURAL SYMBOLS
DENOTES FOOTING SIZE AND ELEVATION
DENOTES PIER SIZE AND ELEVATION
STEP DENOTES FOUNDATION STEP
F# (###.##)
P# [###.##]
1. MANUFACTURERS OF OPEN WEB STEEL JOISTS AND JOIST GIRDERS SHALL BE MEMBERS OF THE
STEEL JOIST INSTITUTE. OPEN WEB STEEL JOISTS SHALL BE DESIGNED, FABRICATED AND
ERECTED IN ACCORDANCE WITH PROVISIONS FOUND IN THE STEEL JOIST INSTITUTE
PUBLICATION, STANDARD SPECIFICATIONS, LOAD TABLES AND WEIGHT TABLES FOR STEEL
JOISTS AND JOIST GIRDERS, LATEST EDITION.
2. WHERE NOTED, OPEN WEB STEEL JOISTS AND JOIST GIRDERS SHALL BE DESIGNED FOR
ADDITIONAL CONCENTRATED LOADS AND MOMENTS AS WELL AS FOR NONSTANDARD MEMBER
GEOMETRIES AS INDICATED ON DRAWINGS AND LOADING DIAGRAMS. CONTRACTOR SHALL
SUBMIT DESIGN CALCULATIONS FOR OPEN WEB STEEL JOISTS AND JOIST GIRDERS DESIGNED
TO RESIST CONCENTRATED LOADS AND MOMENTS.
3. OPEN WEB STEEL JOISTS AND JOIST GIRDERS SHALL RECEIVE ONE SHOP COAT OF PRIMER
PAINT, U.N.O.
4. MODIFY JOIST SHOES, PANEL POINT SPACING, MEMBER CROSS-SECTIONS AND GEOMETRY AS
INDICATED ON ARCHITECTURAL AND STRUCTURAL DRAWINGS TO CONFIRM TO DESIGN
REQUIREMENTS.
5. BRIDGING SHALL MEET THE MINIMUM REQUIREMENTS OF SJI, U.N.O. HORIZONTAL BRIDGING
SHALL BE CONTINUOUS TOP AND BOTTOM, ANCHORED AT EACH END AND WELDED AT SPLICE
LOCATIONS AND TO EACH JOIST. DIAGONAL BRIDGING SHALL BE BOLTED TO EACH JOIST AND
CLAMPED OR WELDED PER REQUIREMENT OF SJI.
6. CONCENTRATED LOADS DUE TO HANGERS, HEADERS, MECHANICAL EQUIPMENT ETC. SHALL BE
SUPPORTED ONLY AT JOIST PANEL POINTS WHERE CONCENTRATED LOADS SUPPORT DO NOT
ALIGN WITH JOIST PANEL POINTS, CONTRACTOR SHALL CONTACT THE ENGINEER AND PROVIDE
SUPPLEMENTAL MEMBERS AS REQUIRED.
1. METAL DECK SHALL BE AS NOTED ON DRAWINGS, FABRICATED AND ERECTED IN ACCORDANCE WITH THE STEEL DECK INSTITUTE, “SDI SPECIFICATIONS, FOR STEEL COMPOSITE DECK, FORM
DECK AND ROOF DECK".
2. THE CONTRACTOR SHALL FURNISH ALL ACCESSORIES INCLUDING CLOSURES, “Z” CLOSURES, COLUMN CLOSURES, SCREED ANGLES AND GIRDER FILLERS, AS REQUIRED.
3. ROOF DECK SHALL RECEIVE ONE SHOP COAT OF PRIMER PAINT.
ROOF DECK SPECIFICATION:
VULCRAFT 1-1/2" TYPE B 18 GAUGE WIDE RIB DECK
ROOF DECK ATTACHMENT:
5/8" PUDDLE WELDS, 36/4 SUPPORT PATTERN WITH #10 TEK SCREW SIDE LAP
CONNECTION
4. CONTRACTOR SHALL PROVIDE PUBLISHED MANUFACTURER'S DATA AND INDEPENDENTLY
CERTIFIED TEST DATA VERIFYING THE SPECIFIED DECK REQUIREMENTS TO THE
ARCHITECT/ENGINEER FOR REVIEW. PROVIDE ENGINEERED AND CHECKED SHOP DRAWINGS
INDICATING LOCATION, GAGE AND SIZE OF EACH PIECE OF DECKING. SHOP DRAWINGS SHALL
CLEARLY SHOW WELDING DETAILS TO CONNECT METAL DECK WITH STRUCTURAL FRAMING AND
SIDE LAP CONNECTION DETAILS.
5. METAL DECK SHALL BE WELDED TO STRUCTURAL STEEL BY WELDERS QUALIFIED FOR THE
PROCEDURE USED, CONSISTENT WITH ANSI/AWS D1.3, “STRUCTURAL WELDING CODE-SHEET
STEEL.” CONTRACTOR SHALL ESTABLISH A WELDING PROCEDURE FOR CONNECTING STEEL
DECKING TO THE STRUCTURAL STEEL. PRIOR TO STEEL DECK ERECTION, EACH WELDER SHALL
BE QUALIFIED USING THE ESTABLISHED PROCEDURE AS WITNESSED BY THE OWNER'S TESTING
AGENCY.
6. NO LOADS SHALL BE HUNG DIRECTLY ABOVE FROM ROOF DECK WITH THE EXCEPTION OF
TERTIARY FIRE PROTECTION PIPING BRANCHES. ALL OTHER HANGERS FOR CEILINGS,
DUCTWORK, ELECTRICAL CONDUIT, PIPING, PRIMARY FIRE PROTECTION PIPING, ETC., SHALL BE
HUNG DIRECTLY FROM STRUCTURAL STEEL WORK OR SUPPLEMENTARY MEMBERS CONNECTED
BETWEEN STRUCTURAL STEEL.
7. DECK INSTALLATION SHALL BE CONTINUOUS OVER AT LEAST THREE SPANS OF FRAMES.
MASONRY NOTES
= 1.0
DEAD LOADS
ROOF DEAD LOAD = 20 PSF
OPEN WEB STEEL JOISTS AND JOIST GIRDERS
METAL DECK
1. ALL WORK SHOWN ON THESE DRAWINGS HAS BEEN DESIGNED IN ACCORDANCE WITH THE
STRUCTURAL REQUIREMENTS OF THE "2018 INTERNATIONAL BUILDING CODE" (IBC) AND TO ALL
OTHER APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS.
2. JOBSITE SAFETY AND CONSTRUCTION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE
CONTRACTOR.
3. THE CONTRACTOR SHALL COORDINATE OPENINGS, SLEEVES, CONCRETE HOUSEKEEPING PADS, INSERTS, AND DEPRESSIONS SHOWN ON THE MEP, ARCHITECTURAL, AND STRUCTURAL
DRAWINGS.
4. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE MEP AND SITE
DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE CONTRACTOR'S
RESPONSIBILITY TO NOTIFY THE ENGINEER PRIOR TO PERFORMING THE WORK.
5. THE CONTRACTOR SHALL VERIFY ALL EXISTING BUILDING INFORMATION SHOWN (DIMENSIONS, EXISTING CONDITIONS, ELEVATIONS, ETC.) AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES
PRIOR TO FABRICATION OF ANY STRUCTURAL COMPONENT. FAILURE TO NOTIFY ENGINEER OF
UNSATISFACTORY CONDITIONS CONSTITUTES ACCEPTANCE OF UNSATISFACTORY CONDITIONS.
6. THE STABILITY OF THE STRUCTURE PRIOR TO COMPLETION IS SOLELY THE RESPONSIBILITY OF
THE CONTRACTOR. THIS RESPONSIBILITY EXTENDS TO ALL RELATED ASPECTS OF THE
CONSTRUCTION ACTIVITY INCLUDING, BUT NOT LIMITED TO, ERECTION METHODS, ERECTION
SEQUENCE, TEMPORARY BRACING, FORMS, SHORING, USE OF EQUIPMENT AND SIMILAR
CONSTRUCTION PROCEDURES.
7. IF THE EXISTING FIELD CONDITIONS DO NOT PERMIT THE INSTALLATION OF THE WORK IN
ACCORDANCE WITH THE DETAILS SHOWN, THE CONTRACTOR SHALL NOTIFY THE
ARCHITECT/ENGINEER IMMEDIATELY AND PROVIDE A SKETCH OF THE CONDITION WITH HIS
PROPOSED MODIFICATION OF THE DETAILS GIVEN ON THE CONTRACT DOCUMENTS. DO NOT
COMMENCE WORK UNTIL CONDITION IS RESOLVED AND MODIFICATION IS APPROVED BY THE
ENGINEER.
8. SHOP DRAWINGS FOR ALL STRUCTURAL MATERIALS TO BE SUBMITTED TO ENGINEER FOR REVIEW PRIOR TO THE START OF FABRICATION OR COMMENCEMENT OF WORK. REVIEW PERIOD SHALL BE
A MINIMUM OF TWO (2) WEEKS.
9. SHOP DRAWINGS SHALL BEAR THE CONTRACTOR'S STAMP OF APPROVAL WHICH SHALL
CONSTITUTE CERTIFICATION THAT THE CONTRACTOR HAS VERIFIED ALL CONSTRUCTION
CRITERIA, MATERIALS, AND SIMILAR DATA AND HAS CHECKED EACH DRAWING FOR
COMPLETENESS, COORDINATION, AND COMPLIANCE WITH THE CONTRACT DOCUMENTS.
10. THE STRUCTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL STRUCTURAL FEATURES,
UNLESS NOTED OTHERWISE.
11. CONTRACTOR TO COMPLY WITH MINIMUM INSPECTION REQUIREMENTS AS PER IBC CHAPTER 17.
12. CONSTRUCTION LOADS SHALL NOT EXCEED DESIGN LOADS AND SHALL NOT BE LOADED UNTIL
CONCRETE HAS REACHED 75% OF SPECIFIED COMPRESSIVE STRENGTH.
1. CONCRETE SHALL BE DESIGNED AND DETAILED IN ACCORDANCE WITH THE BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318-14) AND CONSTRUCTED IN
ACCORDANCE WITH THE CRSI MANUAL OF STANDARD PRACTICE.
2. CONCRETE SHALL CONFORM WITH "SPECIFICATIONS FOR STRUCTURAL CONCRETE" (ACI 301)
AND AS NOTED BELOW.
3. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE 28-DAY STRENGTH AS FOLLOWS:
TYPE f'c MIN (PSI)
FOOTINGS 3000
PIERS 3000
SLABS ON GRADE 4000
SLABS ON METAL DECK 4000
4. AIR ENTRAINMENT SHALL BE 6% IN ALL EXPOSED CONCRETE.
5. MAXIMUM WATER/CEMENT RATIOS:
A. FOUNDATIONS 0.45
6. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (144 PCF +) WITH ALL CEMENT
CONFORMING TO ASTM C150, TYPE I. MAXIMUM AGGREGATE SIZE SHALL BE 1-1/2" FOR
FOOTINGS AND 3/4" FOR WALLS AND SLABS, CONFORMING TO ASTM C33.
7. LEVELING GROUT SHALL BE NON-SHRINK, NON-METALLIC TYPE, FACTORY PRE-MIXED GROUT IN
ACCORDANCE WITH CE-CRD-C621 OR ASTM C109, WITH A MINIMUM COMPRESSIVE 28-DAY
STRENGTH OF 5,000 PSI.
8. REINFORCING STEEL: ASTM A615 GRADE 60, DEFORMED
9. REINFORCING STEEL CLEAR COVER SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE:
A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 4"
B. CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 BARS AND LARGER: 2"
#5 BARS AND SMALLER: 1-1/2"
C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
SLABS, WALLS, JOISTS
#14 BARS AND #18 BARS: 1-1/2"
#11 BARS AND SMALLER: 3/4"
BEAMS AND COLUMNS, PRIMARY REINFORCEMENT, TIES, STIRRUPS, OR SPIRALS: 1-1/2"
10. SUBMIT TO ENGINEER REINFORCING STEEL SHOP DRAWINGS FOR APPROVAL AND MIX DESIGNS
FOR REVIEW PRIOR TO PLACING ANY CONCRETE.
11. PLACING OF CONCRETE SHALL NOT START UNTIL THE PLACEMENT OF REINFORCING HAS BEEN
APPROVED BY THE INSPECTION AGENCY. EPOXY ADHESIVE SHALL BE USED WHERE DOWELS
ARE TO BE INSTALLED INTO EXISTING CONCRETE.
12. PRIOR TO PLACING CONCRETE, THE CONTRACTOR SHALL SUBMIT FOR REVIEW BY THE
STRUCTURAL ENGINEER, CONCRETE MIX DESIGNS PREPARED IN ACCORDANCE WITH THE
REQUIREMENTS INDICATED IN THE GENERAL NOTES..
13. EARLY DRYING OUT OF CONCRETE, ESPECIALLY DURING THE FIRST 24 HOURS, SHALL BE
CAREFULLY GUARDED AGAINST. ALL SURFACES SHALL BE MOIST CURED OR PROTECTED USING
A MEMBRANE CURING AGENT APPLIED AS SOON AS FORMS ARE BRANE CURING AGENT IS USED,
EXERCISE CARE NOT TO DAMAGE COATING.
14. COLD WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI-306R. HOT WEATHER
CONCRETING SHALL BE IN ACCORDANCE WITH ACI-305R.
15. THROUGHOUT CONSTRUCTION, THE CONCRETE WORK SHALL BE ADEQUATELY PROTECTED
AGAINST DAMAGE DUE TO EXCESSIVE LOADING, CONSTRUCTION EQUIPMENT, MATERIALS OR
METHODS, ICE, RAIN, SNOW, EXCESSIVE HEAT, AND FREEZING TEMPERATURES.
1. MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS
FOR MASONRY STRUCTURES (ACI 530-13/TMS 402-13) AND SHALL BE CONSTRUCTED IN
ACCORDANCE WITH THE SPECIFICATIONS FOR MASONRY STRUCTURES (ACI 530.1-13/TMS 602-13), EXCEPT WHERE OTHERWISE MODIFIED BY THESE GENERAL NOTES.
2. MORTAR SHALL CONFORM TO ASTM C270, TYPE M AT ALL LOAD BEARING WALLS; TYPE S AT
INTERIOR PARTITIONS, PARAPETS, AND NON-LOAD BEARING WALLS. ALL PORTLAND CEMENT
SHALL CONFORM TO ASTM C150, TYPE I. LIME SHALL CONFORM TO ASTM C207 AND MASONRY
CEMENT SHALL CONFORM TO ASTM C91.
3. GROUT SHALL CONFORM TO ASTM C476 AND SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE
STRENGTH OF 3000 PSI. SLUMP OF GROUT SHALL BE 8 TO 10 INCHES AND THE MAXIMUM
AGGREGATE SIZE SHALL BE 3/8" (AGGREGATE GRADED TO PRODUCE FINE GROUT IN
CONFORMANCE WITH ASTM C476 AND C404).
4. SOLID AND HOLLOW LOAD BEARING UNITS PER ASTM C90, TYPE N-1, AS REQUIRED TO PROVIDE 28 DAY COMPRESSIVE STRENGTH, f'm SHALL BE 2800PSI.
5. MINIMUM 28-DAY COMPRESSIVE STRENGTH OF MASONRY, f'm SHALL BE 2800 PSI, UNLESS NOTED
OTHERWISE. FULL BED AND HEAD JOINTS SHALL BE PROVIDED.
6. HORIZONTAL JOINT REINFORCING: ASTM A82; 9-GAGE LADDER-TYPE, GALVANIZED.
7. DEFORMED BAR REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 60 AND SHALL BE
FULL HEIGHT OF WALLS UNLESS OTHERWISE NOTED. PROVIDE BAR SPACERS AND POSITIONERS
AS REQUIRED TO PROPERLY LOCATE AND STABILIZE REINFORCING DURING GROUTING
OPERATIONS. GROUT ALL REINFORCED CELLS SOLID WITH GROUT.
8. BUILD AND TEST MASONRY PRISMS DURING CONSTRUCTION TO VERIFY f'm FOR EACH CLASS OF
MASONRY CONSTRUCTION. PRISM TESTS SHALL BE IN ACCORDANCE WITH ASTM E447, METHOD
B.
9. HOLLOW CONCRETE UNITS BELOW GRADE AND SLAB ON GRADE SHALL BE NORMAL WEIGHT AND
HAVE ALL CELLS GROUTED SOLID.
10. PROVIDE AND INSTALL TEMPORARY BRACING REQUIRED INSURING STABILITY OF ALL WALLS
DURING CONSTRUCTION AND UNTIL ERECTION OF ATTACHED STRUCTURAL FRAMING IS
COMPLETED.
11. PROVIDE GALVANIZED HORIZONTAL JOINT REINFORCEMENT IN ALL WALLS AND PARTITIONS AT
16" O.C. UNLESS OTHERWISE SHOWN OR NOTED. PROVIDE ONE (1) PIECE PREFABRICATED
UNITS AT 8" O.C. AT ALL WALL CORNERS AND INTERSECTIONS.
12. LAP SPLICES FOR DEFORMED REINFORCING BARS USED IN MASONRY CONSTRUCTION SHALL BE
50 BAR DIAMETERS.
13. SUBMIT GROUT MIX DESIGN AND MASONRY UNIT CERTIFICATIONS TO THE PRIME PROFESSIONAL
FOR REVIEW.
14. GROUT PLACEMENT SHALL NOT START UNTIL THE PLACEMENT OF REINFORCING HAS BEEN
APPROVED BY THE INSPECTION AGENCY.
15. FILL ALL CELLS IN TOP THREE (3) COURSES BELOW FINISHED FLOOR, CMU LINTELS, BOND
BEAMS, AND BEAM BEARINGS AND CELLS WITH REINFORCEMENT FULL HEIGHT SOLID WITH
GROUT.
16. ALLOW GROUT IN REINFORCED CMU WALLS TO CURE A MINIMUM OF 48 HOURS BEFORE
IMPOSING CONCENTRATED OR OTHER LOADS FROM ABOVE.
17. PROVIDE MASONRY ANCHORS AT 16" O.C. SET ON COURSING AND ATTACHED TO ALL BEAMS, COLUMNS, PARTITIONS, AND WALLS ABUTTING OR EMBEDDED IN MASONRY UNLESS NOTED
OTHERWISE ON PRIME PROFESSIONAL AND STRUCTURAL DRAWINGS.
18. PROVIDE BOND BEAMS WITH TWO (2) #5 HORIZONTAL REINFORCEMENT CONTINUOUS IN ALL
MASONRY WALLS AT EACH FRAMING LEVEL. PROVIDE A MINIMUM OF TWO (2) #4 BARS AT THE
ENDS OF ALL WALLS AND ON EACH SIDE OF EACH OPENING.
19. ALL PIERS AND PARTITIONS SHALL BE BONDED OR ANCHORED TO ADJACENT MASONRY WALLS.
PROVIDE TIES TO ADJACENT FLOOR AND ROOF CONSTRUCTION IN ACCORDANCE WITH DETAILS
ON DRAWINGS.
20. THE CONTRACTOR SHALL VERIFY ALL OPENINGS BELOW LINTELS INDICATED ARE ADEQUATE TO
ACCEPT DOORFRAMES, LOUVERS, ETC. AS SHOWN ON THE PRIME PROFESSIONAL AND
MECHANICAL DRAWINGS. NOTIFY THE PRIME PROFESSIONAL AND STRUCTURAL ENGINEER OF
ANY DISCREPANCIES PRIOR TO LINTEL INSTALLATION.
21. NO OPENINGS SHALL BE PLACED ABOVE ANY LINTEL WITHIN A HEIGHT LESS THAN OR EQUAL TO
THE WIDTH OF THE CLEAR OPENING BELOW THE LINTEL, UNLESS SPECIFICALLY SHOWN OR
APPROVED BY THE STRUCTURAL ENGINEER.
22. ALL MASONRY WORK TO BE EXECUTED IN COLD WEATHER SHALL BE IN CONFORMANCE WITH
THE RECOMMENDATIONS FOR COLD WEATHER CONSTRUCTION FOUND IN THE BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-13/TMS 402-13) AND SHALL BE
CONSTRUCTED IN ACCORDANCE WITH THE SPECIFICATIONS FOR MASONRY STRUCTURES (ACI
530.1-13/TMS 602-13) WITH THE FOLLOWING ADDITIONS: FOR ALL CONDITIONS WHEN
TEMPERATURES FALL BELOW 40 DEGREES F, THE TEMPERATURE OF THE NEWLY LAID MASONRY
OR NEWLY GROUTED MASONRY SHALL BE MAINTAINED ABOVE 32 DEGREES F FOR A MINIMUM OF
24 HOURS USING THE METHODS DESCRIBED IN ACI 530.1.
23. THE TESTING AND INSPECTION AGENCY SHALL MONITOR THE PROPORTIONING, MIXING, AND
CONSISTENCY OF MORTAR AND GROUT; THE PLACEMENT OF MORTAR, GROUT, AND MASONRY
UNITS; AND THE PLACEMENT OF REINFORCING STEEL FOR COMPLIANCE WITH THE CONTRACT
DOCUMENTS.
24. THE CONTRACTOR SHALL PREPARE ONE (1) SET OF PRISMS FOR TESTING AT SEVEN (7) DAYS AND ONE (1) SET FOR TESTING AT 28 DAYS. TESTS ARE TO BE CONDUCTED BY THE INSPECTION AND TESTING AGENCY FOR EACH 3,000 SQUARE FEET OF WALL INSTALLED, BUT NOT LESS THAN
TWO (2) TESTS.
25. ALL WALL SECTIONS AND PIERS LESS THAN TWO SQUARE FEET IN CROSS-SECTIONAL AREA
SHALL BE FULLY GROUTED.
26. PROVIDE VERTICAL MASONRY CONTROL JOINTS AT MAXIMUM 25'-0" ON CENTER UNLESS
DETAILED ON PRIME PROFESSIONAL DRAWINGS, COORDINATE LOCATIONS WITH ARCHITECT.
FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO "THE MANUAL OF
STEEL CONSTRUCTION - (15TH EDITION)", AMERICAN INSTITUTE OF STEEL CONSTRUCTION,
INCLUDING SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, SPECIFICATION FOR
STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS, AND AISC CODE OF STANDARD
PRACTICE.
1. MATERIALS:
STRUCTURAL STEEL ASTM A992
PLATES, ANGLES, CHANNELS ASTM A36 (MIN)
STRUCTURAL STEEL TUBING - SQUARE ASTM A 500, GRADE C
HEADED ANCHOR RODS F1554, GRADE 36
2. ALL BOLTED CONNECTIONS SHALL BE WITH ASTM A325 HIGH STRENGTH BOLTS 3/4"
MINIMUM DIAMETER, UNLESS NOTED OTHERWISE.
3. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS AND SHALL CONFORM TO
"STRUCTURAL WELDING CODE ANSI/AWS D1.1-2011" AMERICAN WELDING SOCIETY.
4. ALL BOLTED CONNECTIONS ON WIND BRACING MEMBERS AND COLUMNS SHALL BE SLIP
CRITICAL CONNECTIONS.
5. WELDING ELECTRODES SHALL BE E70XX FOR MANUAL ARC WELDING AND F7X-EXXX FOR
SUBMERGED ARC WELDING. ALL WELDERS SHALL BE CERTIFIED BY THE AWS. MINIMUM
WELD SIZE SHALL BE 3/16" UNLESS NOTED OTHERWISE.
6. CUTS, HOLES, COPING, ETC. REQUIRED FOR OTHER TRADES OR FIELD CONDITIONS SHALL
BE SHOWN ON THE SHOP DRAWINGS AND MADE IN THE SHOP. CUTTING OR BURNING OF
MAIN STRUCTURAL MEMBERS IN THE FIELD WILL NOT BE PERMITTED.
7. STEEL MEMBERS SHOWN ON PLAN SHALL BE EQUALLY SPACED UNLESS NOTED
OTHERWISE.
8. THE GENERAL CONTRACTOR AND STEEL ERECTOR SHALL NOTIFY THE STRUCTURAL
ENGINEER OF ANY FABRICATION OR ERECTION ERRORS OR DEVIATIONS AND RECEIVE
WRITTEN APPROVAL BEFORE ANY FIELD CORRECTIONS ARE MADE.
9. ALTERNATE CONNECTION DETAILS MAY BE USED IF SUCH DETAILS ARE SUBMITTED TO THE
ENGINEER FOR REVIEW AND APPROVAL. HOWEVER, THE ENGINEER SHALL BE THE SOLE
JUDGE OF ACCEPTANCE AND THE CONTRACTOR'S BID SHALL ANTICIPATE THE USE OF
THOSE DETAILS SHOWN ON THE DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR THE
DESIGN OF SUCH ALTERNATE DETAILS WHICH HE PROPOSES.
10. MAIN SUPPORT MEMBERS FOR THE METAL DECK ARE SHOWN. DURING PREPARATION,
SUBMISSION, AND REVIEW OF SHOP DRAWINGS, ANY ADDITIONAL ANGLES OR
MISCELLANEOUS ATTACHMENT DETAILS REQUIRED TO SUPPORT THE METAL DECK AT THE
REQUIRED ELEVATION SHALL BE PROVIDED BY THE STRUCTURAL STEEL CONTRACTOR.
11. ALL STEEL SHALL BE PAINTED WITH SHOP STANDARD PRIMER UNLESS NOTED OTHERWISE.
12. ALL EXTERIOR EXPOSED STRUCTURAL STEEL SHALL BE HOT-DIPPED GALVANIZED PER
ASTM A123.
13. FIELD WELDED SURFACES WITHIN FOUR (4) INCHES OF WELD SHALL BE CLEANED AND
GROUND SMOOTH. AFTER WELDING COAT THE EXPOSED AREA WITH APPROPRIATE
PRIMER/PAINTS AS SPECIFIED.
14. GUYS AND OTHER BRACING REQUIRED TO PROVIDE LATERAL STABILITY TO STEEL FRAME
SHALL BE ADEQUATELY SIZED AND ANCHORED. THIS BRACING SHALL REMAIN UNTIL
PERMANENT BRACING ELEMENTS AND ATTACHED CONSTRUCTION IS INSTALLED.
15. VISUALLY INSPECT ALL FILLET WELDS.
16. FIELD TEST BOLTED CONNECTIONS AND SHEAR STUDS IN ACCORDANCE WITH AISC.
17. ALL STEEL SHALL BE THOROUGHLY CLEANED BY POWER TOOL CLEANING PRIOR TO
PAINTING. ALL ARCHITECTURALLY EXPOSED STRUCTURAL STEEL SHALL BE CLEANED WITH
COMMERCIAL BLAST CLEANING.
18. ALL DISSIMILAR METALS SHALL BE TREATED OR PROPERLY SEPARATED TO PREVENT
GALVANIC AND/OR CORROSIVE EFFECTS.
19. ALL CONNECTIONS SHALL BE SYMMETRICAL ABOUT THE AXIS OF THE MEMBER
CONNECTED. PROVIDE ONLY ONE GRADE OF BOLT FOR EACH BOLT DIAMETER TO BE USED
IN THE CONNECTIONS. DO NOT MIX GRADE OF BOLTS.
20. THE CONTRACTOR SHALL PREPARE STRUCTURAL STEEL ERECTION AND SHOP DRAWINGS
TO BE SUBMITTED TO THE ENGINEER FOR REVIEW.
STRUCTURAL STEEL
SPECIAL INSPECTIONS:
THE FOLLOWING ITEMS REQUIRE SPECIAL INSPECTION AND TESTING PER IBC 2018 SECTION 1705.
THE INSPECTION SHALL BE PERFORMED BY A SPECIAL INSPECTOR CERTIFIED TO PERFORM THE
TYPES OF INSPECTIONS AND TESTS SPECIFIED.
ITEM DESCRIPTION IBC SECTION
STRUCTURAL STEEL AND WELDING 1705.2 AND 1705.2.1
HIGH STRENGTH BOLTING 1705.2 AND 1705.2.1
COLD-FORMED STEEL DECK 1705.2.2
SOILS 1705.6 AND TABLE 1705.6
CONCRETE AND REINFORCING STEEL TABLE 1705.3
COLD-FORMED STEEL FRAMING 1705.11.2
COMPONENTS AND CLADDING WIND LOADS (PSF)
AREA ZONE 4 (+) ZONE 4 (-) ZONE 5 (+) ZONE 5 (-)
< 5 SF 31.70 -34.34 31.70 -42.27
> 20 SF 30.30 -32.94 30.30 -39.46
> 100 SF 27.04 -29.68 27.04 -32.94
NOTE: WIND LOADS PROVIDED ARE AT THE ULTIMATE (LRFD) LEVEL.
FOUNDATION NOTES:
1. ALLOWABLE SOIL BEARING PRESSURE = 3,000 PSF (AFTER GROUND IMPROVEMENTS)
2. PROVIDE RAMMED AGGREGATE PIERS (DELEGATED DESIGN BY OTHERS) AT EACH COLUMN
FOOTING LOCATION AND AS REQUIRED ALONG WALL FOOTINGS. LOADS SPECIFIED ON THE
FOUNDATION PLAN ARE ASD (SERVICE-LEVEL UNFACTORED). REFER TO THE GEOTECHNICAL
REPORT BY BARRY ISSETT AND ASSOCIATES DATED NOVEMBER 25TH, 2024 AND SPECIFICATION
"30100 - AGGREGATE PIERS" FOR ADDITIONAL INFORMATION.
3. MAXIMUM WALL FOOTING LOAD = 1.5 KIPS PER FOOT (SERVICE LEVEL)
4. BOTTOM OF FOUNDATIONS ALONG BUILDING PERIMETER, UNHEATED AREAS, AND FROST WALLS
SHALL BE PLACED A MINIMUM OF 48 INCHES BELOW THE FINAL EXTERIOR GRADE FOR
PROTECTION AGAINST FROST UPLIFT.
5. THE CONTRACTOR SHALL BE SOLELY RESPONSBILE FOR THE STABILITY OF ALL EXCAVATED
SLOPES AND SHALL PROVIDE TEMPORARY SHEETING/SHORING AS REQUIRED THAT CONFORMS
TO MINIMUM OSHA REQUIREMENTS.
6. THE GEOTECHNICAL ENGINEER SHALL APPROVE ALL BEARING STATA PRIOR TO PLACEMENT OF
ANY CONCRETE FOOTING.
C e tr o n ia R o a d S u it e
A lle n to w n
P
A
.4
.7
EMA-FIRE SCHOOL
DATE
T H
E C
O U
N T
Y O
F S
C H
U Y
L K
IL
L
M
N D
S T
R E
E T
P
O T
T S
V
IL
L E
P
A
DATE
Drawn By:
Y
K
IM
A R
C H
IT
E
C T
S
W
M a rk e t S tr e e t
P o tt s v ill e P
A
T
.6
.4 y k a a ia g m a il.
c o m
T H
E S
C H
U Y
L K
IL
L
C O
U N
T Y
E M
E R
G E
N C
Y S
E R
V
IC
E S
T R
A
IN
IN
G
F A
C
IL
IT
Y
Approved By:
Checked By:
DATE
CONTRACTOR SHALL BE
RESPONSIBLE FOR
VERIFICATION OF ALL
DIMENSIONS & EXISTING
CONDITIONS THAT WILL
AFFECT NEW WORK.
F
IR
E M
E N
'S R
O A
D
F R
A C
K V
IL
L
E
P A
G E
N E
R A
L N
O T
E S
JEB
MSR
MSR
S.1
01/08/25
1 2 3 5 6 7 8 9
B
C
D
E
F
C'
S.11
Aa
5'
2.1 3.1 5.1
H
G
S.10
(-4' - 0")F5
(-2' - 2")F5 (-2' - 2")F5
(-2' - 2")F5
(-4' - 0")F5
(-2' - 2")F5
(-4' - 0")F5(-4' - 0")F5
(-2' - 2")F6 (-2' - 2")F6
(-2' - 2")F5(-2' - 2")F5(-2' - 2")F5(-2' - 2")F5(-2' - 2")F5
(-4' - 0")F5
(-4' - 2")F6
(-4' - 2")F6
(-4' - 0")F5
(-4' - 0")F5 (-4' - 2")F6
(-4' - 0")F5
(-4' - 2")F6
S.10
(-4' - 0")F7 (-4' - 0")F7
(-4' - 0")F7 (-4' - 0")F7 (-4' - 0")F7
(-4' - 0")F7(-4' - 0")F7
(-4' - 0")F7
S.9
S.10
S.9
S.11
5" THICK REINF. CONCRETE
FLOOR SLAB REINF. W/ 6x6 W2.9xW2.9 WWF W/ VAPOR
BARRIER ON 2B STONE BASE
COMPACTED TO 8" DEPTH
REFER TO MEP DRAWINGS FOR
RADIANT HEATING SYSTEM
DETAILS
S.11
(-4' - 0")F5
/2
/2
/2
/2
/2
/2
/2
/2
23' - 0" 23' - 0" 23' - 0" 19' - 0"
12' - 0"
11' - 4" 8" 23' - 4"12' - 8"
20' - 0" 3' - 0" 17' - 0" 6' - 0" 18' - 0" 5' - 0"
4 1/2" 20' - 0" 20' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 40' - 0" 9"
177' - 1 1/2"
P24 [-0' - 8"]
(-4' - 0")F5 P24 [-1' - 4"]
(-4' - 0")F5 P24 [-1' - 4"]
P24 [-1' - 4"]
P24 [-1' - 4"]
P24 [-1' - 4"]
(-4' - 0")F5 P24 [-0' - 8"]
(-4' - 0")F5 P24 [-0' - 8"]
(-4' - 0")F5 P24 [-0' - 8"]
(-4' - 0")F5 P24 [-0' - 8"] P24 [-1' - 4"]
P24 [-1' - 4"]
P24 [-1' - 4"]
P24 [-1' - 4"]
P24 [-1' - 4"]
(-4' - 0")F5 P24 [-0' - 8"]
(-4' - 0")F5 P24 [-0' - 8"](-4' - 0")F5
P24 [-0' - 8"] (-4' - 0")F5
P24 [-0' - 8"]
(-4' - 0")F5 P24 [-0' - 8"]P24 [-0' - 8"]
(-4' - 0")F5 P24 [-0' - 8"]
(-4' - 0")F5 P24 [-0' - 8"]
P24 [-0' - 8"]
P18 [4' - 0"]P18 [4' - 0"]
P24 [4' - 0"] P24 [4' - 0"] P24 [4' - 0"] P24 [4' - 0"]
P24 [4' - 0"]P24 [4' - 0"]P24 [4' - 0"]P24 [4' - 0"]
8" REINF. CONCRETE
SLAB ON GRADE W/
VAPOR BARRIER ON
2B STONE BASE
COMPACTED TO 8"
DEPTH
(SEE S.5 FOR REINF.)
S L O
P E
S
E
A R
C H
S L O
P
S
E
A R
C H
CJ
CJ
CJ
C J
C J
C J
C J
15 KIPS 18 KIPS 20 KIPS 28 KIPS 36 KIPS 29 KIPS 45 KIPS 28 KIPS
51 KIPS 48 KIPS
55 KIPS
86 KIPS
75 KIPS
51 KIPS
28 KIPS37 KIPS
14 KIPS
26 KIPS
41 KIPS40 KIPS
25 KIPS
14 KIPS
14 KIPS
37 KIPS27 KIPS21 KIPS
5 KIPS
30 KIPS 33 KIPS
16 KIPS
20 KIPS
8 KIPS 10 KIPS
11 KIPS
10 KIPS 10 KIPS
10 KIPS 20 KIPS 20 KIPS 10 KIPS
10 KIPS20 KIPS20 KIPS10 KIPS
HSS6x6x3/8
CANOPY COLUMN
(TYP)
RAMMED AGGREGATE PIER
(TYP) SIZE, LOCATION AND
DESIGN BY OTHERS
/2
/2
45 KIPS
CONCRETE PAD - SEE
SITE PLANS (TYP)
FOUNDATION PLAN NOTES:
1. FOUNDATION ELEVATIONS ARE BASED ON A STRUCTURAL CONCRETE FINISHED FLOOR SLAB ELEVATION OF 0'-0" (EQUAL TO
ARCHITECTURAL ELEVATION OF 0'-0")
2. CONCRETE FLOOR SLABS SHALL BE PLACED ON A 15 MIL VAPOR BARRIER AND 2B STONE (AASHTO #57 CRUSHED STONE AGGREGATE) BASE COMPACTED TO DEPTH AS SPECIFIED ON PLANS. THICKNESS OF FLOOR SLABS VARY, SEE PLANS, SECTIONS, AND DETAILS.
3. ISOLATED COLUMN AND WALL FOOTING SIZE ARE INDICATED AS: F# (SEE SCHEDULE FOR REINFORCING)
4. ELEVATIONS INDICATED AT FOOTING LOCATIONS ARE TO BOTTOM OF SPREAD FOOTING.
5. COLUMN PIER SIZE ARE INDICATED AS: P#. TOP OF PIERS TO BE SET 8" BELOW FLOOR SLAB ELEVATION (U.N.O.).
6. ALL FOOTINGS EXPOSED TO FREEZE-THAW CONDITIONS SHALL BE SET A MINIMUM OF 4'-0" DEEP MEASURED FROM FINISHED GRADE TO
THE BOTTOM OF THE FOOTING. SEE CIVIL PLANS FOR FINISHED GRADE ELEVATIONS.
7. "CJ" DESIGNATES SAW CUT CONTROL JOINT. FOR CONTROL JOINT SPACING IN OFFICE AREA, SEE TYPICAL DETAIL ON S.5.
8. "XX KIPS" INDICATES TOTAL UNFACTORED COLUMN REACTION AT EACH FOOTING FOR RAMMED AGGREGATE PIER DESIGN (BY OTHERS).
9. REFER TO ARCHITECTURAL, MECHANICAL, EQUIPMENT, AND CIVIL SITE PLANS FOR ADDITIONAL INFORMATION NOT INDICATED ON THESE
PLANS. CONTRACTOR TO COORDINATE LOCATION OF UTILITIES WITH PLAN INFORMATION.
10. SEE TYPICAL DETAILS, SECTIONS, AND NOTES FOR ADDITIONAL INFORMATION NOT REPEATED HERE.
11. CONTRACTOR TO COORDINATE AND VERIFY THE FOUNDATION WALL SECTIONS TO INCORPORATE WITH ARCHITECTURAL DETAIL.
C e tr o n ia R o a d S u it e n to w n
P
A
.4
.7
EMA-FIRE SCHOOL
DATE
T H
E C
O U
N T
Y O
F S
C H
U Y
L K
IL
L
M
N D
S T
R E
E T
P
O T
T S
V
IL
L E
P
A
DATE
Drawn By:
Y
K
IM
A R
C H
IT
E
C T
S
W
M a rk e t S tr e e t
P o tt s v ill e P
A
T
.6
.4 y k a a ia g m a il.
c o m
T H
E S
C H
U Y
L K
IL
L
C O
U N
T Y
E M
E R
G E
N C
Y S
E R
V
IC
E S
T R
A
IN
IN
G
F A
C
IL
IT
Y
Approved By:
Checked By:
DATE
CONTRACTOR SHALL BE
RESPONSIBLE FOR
VERIFICATION OF ALL
DIMENSIONS & EXISTING
CONDITIONS THAT WILL
AFFECT NEW WORK.
F
IR
E M
E N
'S R
O A
D
F R
A C
K V
IL
L
E
P A
F O
U N
D A
T
IO
N P
L A
N
JEB
MSR
MSR
S.2
01/08/25
1/8" = 1'-0"
FOUNDATION PLAN
B
C
D
E
F
C'
S.11
Aa
5'
3 EQ. SPA. =
12' - 0"
5 EQ. SPA. =
12' - 0"
4 EQ. SPA. =
12' - 0"
2.1 3.1 5.1
H
G
S.10
S.10
S.9
S.10
S.9
S.11
S.11
6' - 0" 6' - 0"
M C -1
M C -2
M C -2
M C -3
M C -4
M C -3
M C -1
M C -2
M C -2
M C -5
M C -6
M C -5
M C -2
M C -2
M C -3
M C -3
M C -3
M C -3
M C -2
M C -2
OPERABLE
PARITION BELOW.
SEE ARCH DWGS
SEE RTU CURB
SUPPORT DETAIL ON S.7
(TYP @ EACH RTU)
11' - 4" 8"
12' - 0"
(2 )1
K
(2 )1
K
(2 )1
K
(2 )1
K
W X
-2
/2
W X
-2
/2
W X
W X
W X
W X
W X
-2
/2
W X
-2
/2
W X
-2
/2
W X
-2
/2
W X
-2
/2
W16X31
( -2 1/2" )
W18X35
( -2 1/2" )
W16X31
( -2 1/2" )
W16X31
( -2 1/2" )
W24X55
( -2 1/2" )
W16X31
( -2 1/2" )
W18X35
( -2 1/2" )
W X
-2
/2
W18X40
( -2 1/2" )
W18X35
( -2 1/2" )
W16X31
( -2 1/2" )
W16X31
( -2 1/2" )
W24X55
( -2 1/2" )
W16X31
( -2 1/2" )
W X
W X
W X
W X
-2
/2
W X
-2
/2
W X
-2
/2
W X
-2
/2
W X
-2
/2
W X
-2
/2
W18X35
( -2 1/2" )
W24X55
( -2 1/2" )
W18X35
( -2 1/2" )
W18X35
( -2 1/2" )
W18X35
( -2 1/2" )
W16X31
( -2 1/2" )
W16X31
( -2 1/2" )
W24X55
( -2 1/2" )
W16X31
( -2 1/2" )
W18X40
( -2 1/2" )
W16X31
( -2 1/2" )
W X
-2
/2
W X
-2
/2
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
W X
-3
W X
-3
W16X31
( -3' - 0" )
K
W X
-3
/8
W12X26
( -3' - 5 3/8" )
W12X26
( -3' - 5 3/8" )
W12X26
( -3' - 5 3/8" )
W12X26
( -3' - 5 3/8" )
W12X26
( -3' - 5 3/8" )
W12X26
( -3' - 5 3/8" )
W X
-3
/8
W X
-3
/8
W X
-3
/8
W X
-3
/8
W X
-3
/8
W X
-3
/8
W X
-3
/8
W X
-3
/8
W X
-3
/8
W X
-3
/8
W X
-3
/8
W X
-3
/8
W X
-3
/8
W X
-3
/8
W X
-3
/8
K
W16X31
( -3' - 0" )
W12X26
( -3' - 5 3/8" )
K
W16X31
( -3' - 0" )
W16X31
( -3' - 0" )
W X
-3
W X
-3
W X
-3
W X
-3
W12x19 (-3'-0")
/2
C A
N T
/8
H
S S
H
S S
H
S S
H
S S
H
S S
H
S S
H
S S
H
S S
H
S S
H
S S
H
S S
H
S S
H
S S
H
S S
H
S S
H
S S
K
(2 )2
K
(2 )2
K
(2 )2
K
K
(2 )1
K
(2 )1
K
(2
)2 K
ROOF FRAMING NOTES:
1. ALL ELEVATIONS SHOWN ARE TO TOP OF ROOF FRAMING MEMBERS BASED ON A FINISHED FLOOR ELEVATION OF 0'-0".
2. ELEVATION FOR TOP OF ROOF FRAMING MEMBERS IS 14'-1 1/2". VARIATIONS IN ELEVATION ARE INDICATED AS (±##").
3. HORIZONTAL SPACING (CENTER TO CENTER) OF ROOF MEMBERS TO BE:
BEAMS: AS NOTED ON PLANS
JOISTS: 6'-0" MAX.
TRUSS: 5'-0" MAX.
BRIDGING: 1/3 POINTS OF SPAN
4. COORDINATE ROOF OPENINGS AND UTILITY PENETRATION SIZE, LOCATION, AND SUPPORT FRAMING WITH MANUFACTURES CLEARANCE REQUIREMENTS. FOR OPENINGS
LARGER THAN 12" REFER TO TYPICAL DETAILS FOR ADDITIONAL FRAMING REQUIREMENTS.
5. ROOF DECKING TO BE 1 1/2" TYPE B x 18 GA. GALVANIZED METAL DECKING. REFER TO DETAILS AND WALL SECTIONS FOR ADDITIONAL INFORMATION.
6. "MC-#" INDICATES MOMENT CONNECTION TYPE - REFER TO DETAILS FOR DESIGN.
7. REFER TO ARCHITECTURAL AND MECHANICAL PLANS FOR ADDITIONAL INFORMATION NOT INDICATED ON THESE PLANS.
8. SEE TYPICAL DETAILS, SECTIONS, AND NOTES FOR ADDITIONAL INFORMATION NOT REPEATED HERE.
9. CONTRACTOR TO COORDINATE FINAL RTU CURB DIMENSIONS WITH EQUIPMENT VENDOR FINAL SUBMISSION.
10. JOIST MANUFACTURER TO DESIGN FOR DEFLECTION AND CAMBER TOP CHORD AS REQUIRED.
11. DESIGNATES MOMENT CONNECTION
12. "+HSS" INDICATES ADDITIONAL DECK SUPPORT STEEL. SEE SECTION 2/S.10 FOR ADDITIONAL INFORMATION.
C e tr o n ia R o a d S u it e n to w n
P
A
.4
.7
EMA-FIRE SCHOOL
DATE
T H
E C
O U
N T
Y O
F S
C H
U Y
L K
IL
L
M
N D
S T
R E
E T
P
O T
T S
V
IL
L E
P
A
DATE
Drawn By:
Y
K
IM
A R
C H
IT
E
C T
S
W
M a rk e t S tr e e t
P o tt s v ill e P
A
T
.6
.4 y k a a ia g m a il.
c o m
T H
E S
C H
U Y
L K
IL
L
C O
U N
T Y
E M
E R
G E
N C
Y S
E R
V
IC
E S
T R
A
IN
IN
G
F A
C
IL
IT
Y
Approved By:
Checked By:
DATE
CONTRACTOR SHALL BE
RESPONSIBLE FOR
VERIFICATION OF ALL
DIMENSIONS & EXISTING
CONDITIONS THAT WILL
AFFECT NEW WORK.
F
IR
E M
E N
'S R
O A
D
F R
A C
K V
IL
L
E
P A
L O
W R
O O
F F
R A
M
IN
G P
L A
N
JEB
MSR
MSR
S.3
01/08/25
1/8" = 1'-0"
LOW ROOF FRAMING PLAN
B
C
D
E
F
C'
S.11
Aa
5'
2.1 3.1 5.1
H
G
S.10
S.9
S.9
S.11
S.11
(T Y
P
E Q
M C -7
M C -7
M C -8
M C -8
M C -8
M C -7
M C -8
M C -8
M C -7
M C -8
W X
-2
/2
W X
-2
/2
W X
-2
/2
W X
-2
/2
W X
-2
/2
W X
-2
/2
W18X35
W X
-2
/2
W X
-2
/2
W18X35
W21X44
W21X44
W21X44
30K8
30K8
30K8
30K8
30K8
30K8
30K8
30K8
30K8
30K8
30K8
30K8
30K8
30K8
ROOF FRAMING NOTES:
1. ALL ELEVATIONS SHOWN ARE TO TOP OF ROOF FRAMING MEMBERS BASED ON A FINISHED FLOOR ELEVATION OF 0'-0".
2. ELEVATION FOR TOP OF ROOF FRAMING MEMBERS IS 18'-5 1/2". VARIATIONS IN ELEVATION ARE INDICATED AS (±##").
3. HORIZONTAL SPACING (CENTER TO CENTER) OF ROOF MEMBERS TO BE:
BEAMS: AS NOTED ON PLANS
JOISTS: 6'-0" MAX.
TRUSS: 5'-0" MAX.
BRIDGING: 1/3 POINTS OF SPAN
4. COORDINATE ROOF OPENINGS AND UTILITY PENETRATION SIZE, LOCATION, AND SUPPORT FRAMING WITH MANUFACTURES CLEARANCE REQUIREMENTS. FOR OPENINGS
LARGER THAN 12" REFER TO TYPICAL DETAILS FOR ADDITIONAL FRAMING REQUIREMENTS.
5. ROOF DECKING TO BE 1 1/2" TYPE B x 18 GA. GALVANIZED METAL DECKING. REFER TO DETAILS AND WALL SECTIONS FOR ADDITION INFORMATION.
6. "MC-#" INDICATES MOENT CONNECTION TYPE - REFER TO DETAILS FOR DESIGN.
7. REFER TO ARCHITECTURAL AND MECHANICAL PLANS FOR ADDITIONAL INFORMATION NOT INDICATED ON THESE PLANS.
8. SEE TYPICAL DETAILS, SECTIONS, AND NOTES FOR ADDITIONAL INFORMATION NOT REPEATED HERE.
9. CONTRACTOR TO COORDINATE FINAL RTU CURB DIMENSIONS WITH EQUIPMENT VENDOR FINAL SUBMISSION.
10. JOIST MANUFACTURER TO DESIGN FOR DEFLECTION AND CAMBER TOP CHORD AS REQUIRED.
11. DESIGNATES MOMENT CONNECTION
C e tr o n ia R o a d S u it e n to w n
P
A
.4
.7
EMA-FIRE SCHOOL
DATE
T H
E C
O U
N T
Y O
F S
C H
U Y
L K
IL
L
M
N D
S T
R E
E T
P
O T
T S
V
IL
L E
P
A
DATE
Drawn By:
Y
K
IM
A R
C H
IT
E
C T
S
W
M a rk e t S tr e e t
P o tt s v ill e P
A
T
.6
.4 y k a a ia g m a il.
c o m
T H
E S
C H
U Y
L K
IL
L
C O
U N
T Y
E M
E R
G E
N C
Y S
E R
V
IC
E S
T R
A
IN
IN
G
F A
C
IL
IT
Y
Approved By:
Checked By:
DATE
CONTRACTOR SHALL BE
RESPONSIBLE FOR
VERIFICATION OF ALL
DIMENSIONS & EXISTING
CONDITIONS THAT WILL
AFFECT NEW WORK.
F
IR
E M
E N
'S R
O A
D
F R
A C
K V
IL
L
E
P A
H
IG
H R
O O
F F
R A
M
IN
G P
L A
N
JEB
MSR
MSR
S.4
01/08/25
1/8" = 1'-0"
HIGH ROOF FRAMING PLAN
TYP. FROST WALL
THICKENED SLAB DETAIL
CRACK CONTROL JOINTS SAW CUT JOINTS
TYPICAL ISOLATION JOINT DETAILS
(M
IN
8"
T
T /3
"CSJ" = FORMED CONSTRUCTION JOINT
T
T /3
SPACE AT 15'-0" MAX EACH WAY IN OFFICE AREA
SAW CUT - 1/4" DEPTH
(SAW WITHIN 24 HRS.
OF PLACING
CONCRETE)
DIAMOND
PATTERN
CIRCLE
PATTERN
WALL
TRIANGLE
PATTERN
#4 REBAR @ 12" O.C.
#4 BENT REBAR
@ 12" O.C.
1/4"
PREMOLDED
JOINT FILLER
STOP
REINFORCING
6" FROM JOINT
STOP REINFORCING
6" FROM JOINT
DEPRESSED SLAB DETAIL
T
V A
R
IE
S
S E
E P
L A
N
2T
T
#4 NOSING BAR
3" 3"
SEE GARAGE SLAB
REINFORCEMENT
DETAIL THIS SHEET
1/3 DEPTH (SAW WITHIN
24 HRS. OF PLACING
CONCRETE)
REINFORCEMENT BAR
TRIANGLE
PATTERN
SCALE: 3/4"=1'-0"
SCALE: 3/4"=1'-0"
SCALE: 3/4"=1'-0"
WELDED WIRE FABRIC
CONCRETE WALL CORNER REINFORCING CONCRETE WALL CORNER REINFORCING
NOTES:
1. DO NOT EXTEND HORIZONTAL
REINFORCING BARS THROUGH
CONTROL JOINTS. TERMINATE REBAR
3" BEFORE CONTROL JOINT.
2. TYPE OF CONTROL JOINT USED MAY
VARY FROM TYPE SHOWN.
CONTRACTORS OPTION TO USE
ALTERNATIVE JOINT TYPE.
SCALE: 3/4"=1'-0"
T Y
P
NOTES:
1. DO NOT EXTEND HORIZONTAL REINFORCING BARS
THROUGH CONTROL JOINTS. TERMINATE REBAR 3"
BEFORE CONTROL JOINT.
2. TYPE OF CONTROL JOINT USED MAY VARY FROM TYPE
SHOWN. CONTRACTORS OPTION TO USE
ALTERNATIVE JOINT TYPE.
T Y
P
ALIGN WALL AND
FLOOR
CONTROL
JOINTS
10'-0" MIN.
SEE PLANS
SCALE: 3/4"=1'-0"
3"
3"
MIN
44 BAR DIA
MIN
44 BAR DIA
MIN
44 BAR DIA
M
IN
B
A R
D
IA M
IN
B
A R
D
IA
U.N.O.
1' - 6"
INTERIOR NON-LOAD
BEARING METAL STUD WALL
WELDED WIRE
FABRIC (SEE PLAN)
X X X X X X X X
(2) #5 CONT REBAR
GARAGE SLAB REINFORCEMENT
#5 REBAR @ 12" O.C. EW
COORDINATE SLAB FINISH W/
ARCHITECTURAL DRAWINGS
"CJ" = SAWED CONTROL JOINT -
SEE PLANS FOR GARAGE SLAB LOCATIONS
TYPICAL CONCRETE SLAB AND WALL
OPENING REBAR REINFORCING LAYOUT
WALL/FOOTING PIPE SLEEVE DETAIL
SCALE: 3/4"=1'-0"
*UTILITY PIPE/CONDUIT SEPARATION PER CIVIL
DESIGN DETAILS
SCALE: 3/4"=1'-0"
M
IN
C L R
MIN.
1' - 0"
C L R
1' - 11" *
2" CLR.
PIPE SLEEVE
(2"+PIPE DIA.)
REINF. REBAR (SEE WALL SECTIONS)
ADDITIONAL REBAR @ EACH FACE
(SIZE TO MATCH ADJACENT HORIZ.
REINF.)
F O
O T
IN
G
F O
U N
D A
T
IO
N W
A L
L
1'
6"
8"
OPENING O
P
E N
IN
G
2" CLR.
C L R
C e tr o n ia R o a d S u it e n to w n
P
A
.4
.7
EMA-FIRE SCHOOL
DATE
T H
E C
O U
N T
Y O
F S
C H
U Y
L K
IL
L
M
N D
S T
R E
E T
P
O T
T S
V
IL
L E
P
A
DATE
Drawn By:
Y
K
IM
A R
C H
IT
E
C T
S
W
M a rk e t S tr e e t
P o tt s v ill e P
A
T
.6
.4 y k a a ia g m a il.
c o m
T H
E S
C H
U Y
L K
IL
L
C O
U N
T Y
E M
E R
G E
N C
Y S
E R
V
IC
E S
T R
A
IN
IN
G
F A
C
IL
IT
Y
Approved By:
Checked By:
DATE
CONTRACTOR SHALL BE
RESPONSIBLE FOR
VERIFICATION OF ALL
DIMENSIONS & EXISTING
CONDITIONS THAT WILL
AFFECT NEW WORK.
F
IR
E M
E N
'S R
O A
D
F R
A C
K V
IL
L
E
P A
T Y
P
IC
A L
C O
N C
R E
T E
D E
T A
IL
S
JEB
MSR
MSR
S.5
01/09/25
COLUMN FOOTING SCHEDULE
MARK DIMENSIONS LONG REINF.
F4
F5
F6
F7
5'-6" x 5'-6" x 1'-6"
5'-0" x 5'-0" x 1'-6"
6'-0" x 6'-0" x 1'-6"
7'-0" x 7'-0" x 1'-6"
(5) #5
(6) #5
(7) #5
(8) #5
(5) #5
(6) #5
(7) #5
(8) #5
SHORT REINF. REMARKS
TOP & BOT
TOP & BOT
TOP & BOT
TOP & BOT
COLUMN PIER SCHEDULE
MARK DIMENSIONS REINFORCING
P16
P24
1'-4" x 1'-4"
2'-0" x 2'-0"
(8) #6
(8) #8
REINF. TIES
(2) #3 @ 12"
(2) #3 @ 12"
BASE PLATE
FIRST FLOOR = 0'-0"
HIGH ROOF = 18'-5 1/2"
COLUMN
NO.
LEVEL
/4
BP-1
H S
S x x /2
BP-1 BP-1
/4
BP-5
/4
BP-1
/4
H S
S x x /2
Aa-4, Aa-5'
G-1, G-2.1, G-3.1, G-5.1, H-1, H-2.1, H-3.1, H-5.1
C'-5, C'-6, C'-7, C-2, C-3, D-2, E-2, E-3, E-5, E-6, E-7
A-1, F-1 A-8, B-9, C'-9, E-9, F-8
H S
S x x /2
H S
S x x /8
H S
S x x /2
ENTRANCE CANOPY = 11'-1 1/2"
LOW ROOF = 14'-1 1/2"
CANOPY STEEL = 10'-8 1/8"
/8
/2
A-2, A-3, A-5, A-6, A-7, C-1, E-1, F-2, F-3, F-5, F-6, F-7
B-8, C'-8, E-8
BP-3
/4
BP-2
/4
H S
S x x /2
H S
S x x /2
/2
/2
H S
S x x /2
BP-4
/4
A-9, F-9
BASE PLATE "BP-1 "
SCALE: 3/4"=1'-0"
1' - 6"
1' - 4" 1' - 2"
5/16"
4" 1' - 2"
7" 7"
T Y
P
/2
3/4" THK
BASE PLATE
(4) 3/4" DIA. ASTM
F1554 GR 36 HEADED
ANCHOR BOLTS (12"
MIN. EMBEDMENT)
BASE PLATE "BP-2 "
SCALE: 3/4"=1'-0"
BASE PLATE "BP-3 "
SCALE: 3/4"=1'-0"
T Y
P
3" 6" 2" TYP
1 1/4" THK
BASE PLATE
5/16"
(6) 1" DIA. ASTM
F1554 GR 36 HEADED
ANCHOR BOLTS (12"
MIN. EMBEDMENT)
8" 8"
T Y
P
TYP
3"
1 1/4" THK
BASE PLATE
5/16"
(6) 1" DIA. ASTM
F1554 GR 36 HEADED
ANCHOR BOLTS (12"
MIN. EMBEDMENT)
1' - 6"
1' - 4"
BASE PLATE "BP-4 "
SCALE: 3/4"=1'-0"
BASE PLATE "BP-5 "
SCALE: 3/4"=1'-0"
T Y
P
1 1/2" THK
BASE PLATE
5/16"
(6) 1" DIA. ASTM
F1554 GR 36 HEADED
ANCHOR BOLTS (12"
MIN. EMBEDMENT)
8" 8"
TYP
2"
1 1/4" THK
BASE PLATE
5/16"
(6) 1" DIA. ASTM
F1554 GR 36 HEADED
ANCHOR BOLTS (12"
MIN. EMBEDMENT)
5" 1' - 1"
7" 7"
2"2"
/4
COVER
2" CLR.
GRADE - SEE
CIVIL/SITE
DRAWINGS
COLUMN - SEE SCHEDULE
SLAB - SEE PLAN FOR
THICKNESS AND REINF.
COLUMN FOOTING - SEE
PLAN AND SCHEDULE
SEE SCHED.
S E
E S
C H
E D
COLUMN PIER - SEE PLAN
AND SCHEDULE
BASE PLATE W/ ANCHOR
BOLTS - SEE BASE PLATE
DETAILS FOR SIZE AND TYPE1/4" THK LEVELING PLATE
1" THK. NON-SHRINK
HIGH STRENGTH GROUT
/4
COVER
2" CLR.
COLUMN - SEE SCHEDULE
COLUMN FOOTING - SEE
PLAN AND SCHEDULE
SEE SCHED.
S E
E S
C H
E D
BASE PLATE W/ ANCHOR
BOLTS - SEE BASE PLATE
DETAILS FOR SIZE AND TYPE1/4" THK LEVELING PLATE
1" THK. NON-SHRINK
HIGH STRENGTH GROUT
ISOLATION JOINT AT COLUMN -
SEE TYPICAL DETAILS
ISOLATION JOINT AT COLUMN -
SEE TYPICAL DETAILS
2x4 KEY
COLUMN FOOTING AT EXTERIOR
COLUMN FOOTING AT INTERIOR
9" (GARAGE)
4 1/2" (OFFICE)
S E
E P
L A
N
RAMMED AGGREGATE
PIER (DESIGN BY OTHERS)
RAMMED AGGREGATE
PIER (DESIGN BY OTHERS)
PIER TIE LAYOUT DETAILS
SINGLE TIE
(4) VERT
BARS
NOTES:
1. REFER TO PIER SCHEDULE FOR SIZE OF VERTICAL REBAR
2. TIE BARS SIZES TO BE #3 REBAR
3. PROVIDE (3) TIE BARS AT 6" O.C. TOP & BOTTOM. REMAINING BARS TO
BE SPACED @ 12" O.C.
4. REFER TO FOUNDATIO PLAN(S) FOR PIER SIZES (P#) AND LOCATIONS
DOUBLE TIE
(6) VERT
BARS
DOUBLE TIE
(8) VERT
BARS
3 TIE SET
(12) VERT
BARS
VERTICAL REBAR
PER PIER
SCHEDULE
3 TIE SET (12)
VERT BARS
REBAR PER FOOTING SCHEDULE
SINGLE TIE-(#) VERTICAL
BARS PER SCHEDULE
P E
R S
C H
E D
U L E
TYPICAL BOND BEAM
DETAIL AT CORNER
CONTROL JOINTS
TYPICAL INTERSECTION
OF MASONRY WALLS TYPICAL EXPANSION JOINT AT COLUMN
SCALE: 3/4"=1'-0"
SCALE: 3/4"=1'-0"
SCALE: 3/4"=1'-0" SCALE: 3/4"=1'-0"
(3)#5 VERT. REBAR
(GROUT CORES
SOLID)
(2)#5 BENT REBAR
x 5'-0" LONG
(2'-6" EA. LEG)
(2)#5 REBAR BOND BEAM
REINFORCING U.NO.
CAULK & JOINT
FILLER (B.S.)
SYTHETIC RUBBER
CONTROL JOINT
BUILDING PAPER(1) #5 (TYP)
GROUT CORES
SOLID @ REINF
3000 PSI CONC GROUT
CONT. HORIZ. TRUSS
TYPE JOINT REINF.
AT 16" o.c.
(1) #5 VERTICAL BAR -
GROUT CORES SOLID
w/ 3000 psi CONC.
GROUT
STEEL
COLUMN
WIRE MASONRY
ANCHOR AT
16" o.c. VERT
2" WIDE Z
STRAPS @
16" o.c.
L A
P D
IS
T
A N
C E
M
IN
C e tr o n ia R o a d S u it e n to w n
P
A
.4
.7
EMA-FIRE SCHOOL
DATE
T H
E C
O U
N T
Y O
F S
C H
U Y
L K
IL
L
M
N D
S T
R E
E T
P
O T
T S
V
IL
L E
P
A
DATE
Drawn By:
Y
K
IM
A R
C H
IT
E
C T
S
W
M a rk e t S tr e e t
P o tt s v ill e P
A
T
.6
.4 y k a a ia g m a il.
c o m
T H
E S
C H
U Y
L K
IL
L
C O
U N
T Y
E M
E R
G E
N C
Y S
E R
V
IC
E S
T R
A
IN
IN
G
F A
C
IL
IT
Y
Approved By:
Checked By:
DATE
CONTRACTOR SHALL BE
RESPONSIBLE FOR
VERIFICATION OF ALL
DIMENSIONS & EXISTING
CONDITIONS THAT WILL
AFFECT NEW WORK.
F
IR
E M
E N
'S R
O A
D
F R
A C
K V
IL
L
E
P A
C O
N C
R E
T E
A N
D M
A S
O N
R Y
D E
T A
IL
S
JEB
MSR
MSR
S.6
01/09/25
3/16" = 1'-0"
COLUMN SCHEDULE
TYPICAL JOIST
REINFORCING DETAIL
NOTE: A WEB STIFFENER MUST BE APPLIED TO ANY JOIST WHEN
A CONCENTRATED LOAD IS PLACED ON THE JOIST 4" OR MORE
AWAY FROM A PANEL POINT.
SCALE: 3/4"=1'-0"
P A
N E
L P
O
IN
T
P A
N E
L P
O
IN
T
CONCENTRATED
LOAD DUE TO
MECH
EQUIP, ETC.
(2) ANGLE 1 1/2x1 1/2x1/8 B.S. (TYP)+/- 2'-0"
+/- 2'-0"
NOTES:
1. ALL DIMENSIONS RELATIVE TO RTU SHALL BE COORDINATED
W/MEP DRAWINGS
2. LOCATE HSS @ JOIST PANEL POINTS WHERE APPLICABLE.
3. PROVIDE TWO (2) FRAMES FOR DUCT PENETRATIONS PER RTU
TYPICAL RTU CURB SUPPORT DETAIL
SCALE: 3/4"=1'-0"
SECTION
PLAN
ROOF FRAMING
PROVIDE TUBE STEEL CURB
AS SHOWN BELOW
CONTINUOUS AROUND
ENTIRE PERIMETER OF UNIT
EXTEND TUBE STEEL TO NEXT
ROOF FRAMING MEMBER
WHEN RTU EXTENDS PAST
ROOF TOP
UNIT (RTU)
DUCT
PENETRATION
FIELD WELD ANGLE's TO ROOF
FRAMING (TYP. BOTH SIDES)
METAL ROOF DECK
ROOF FRAMING
HSS 6x3x5/16 (LSH) w/ (2) L2x2x5/16 (SHOP WELD TO
TUBE)
TYPICAL FRAMING FOR DUCT OPENINGS
ANGLE 7x4x3/8" (LLH)
(THIS DETAIL APPLIES FOR OPENINGS 1'-0" & LARGER)
NOT TO SCALE
* DIMENSION VARIES - SEE MECH. &
ARCH. DWGS.
CLIP ANGLES
4x4x5/16x0'-6" LONG
ANGLE 3 1/2x3 1/2x5/16
(1'-0" to 5'-0")
ANGLE 5x3 1/2x5/16 (LLV)
(5'-0" to 6'-0")
ANGLE 6x3 1/2x5/16 (LLV)
(6'-0" to 8'-0")
NOTE:
1. NO OPENINGS SHALL BE CUT IN FLOOR OR ROOF DECK UNLESS
THEY CAN BE IMMEDIATELY PROTECTED BY THE G.C. IN
ACCORDANCE w/ OSHA REQUIREMENTS.
2. CONTRACTOR IS RESPONSIBLE FOR PROVIDING & INSTALLING ALL
STRUCTURAL STEEL, MISC STEEL, AND LOOSE LINTELS THAT ARE
NECESSARY TO SUPPORT ALL ROOF TOP MOUNTED EQUIPMENT.
3. CONTRACTOR TO COORDINATE SIZE, LOCATION, AND DUCT
FRAMING CLEARANCES WITH MEP AND ARCH. DRAWINGS.
4. NO STRUCTURAL FRAMING MEMBERS ARE TO BE CUT, MODIFIED, OR
MOVED TO PLACE DUCT OPENINGS.
SEE MEP DWGS
S E
E M
E P
D W
G S
CENTER (TYP)
1/4" MAX. FROM
BEARING
2 1/2" MIN.
ROOF JOIST
(SEE PLAN)
ROOF JOIST
(SEE PLAN) ROOF BEAM
(SEE PLAN)
2 1/2" JOIST SEAT
METAL DECK
3/16" 2"
3/16" 2"
TYP.
TYPICAL INTERIOR GIRDER TO
JOIST CONNECTION
SCALE: 3/4"=1'-0"
HSS COLUMN
SHEAR TAB
CONNECTION (SEE
TYPICAL DETAILS)
ROOF DECK
CONNECTION PLATE TOP &
BOTTOM (SEE DETAILS FOR
GEOMETRY AND
ADDITIONAL INFORMATION)
ROOF BEAM ROOF BEAM
BEAM TO COLUMN MOMENT
CONNECTION DETAIL
SCALE: 3/4"=1'-0"
(T Y
P
/2
(T Y
P
S P
A
3"3/8" THK SHEAR TAB W/
SLOTTED HOLES FOR
3/4" DIA. A325N BOLTS
COPE BEAM FLANGE AS
REQUIRED AT GIRDER
CONNECTIONS
WIDE FLANGE GIRDER
OR HSS COLUMN
FLOOR BEAM W/ STD
HOLES IN WEB
1/4"
1/4"
TYPICAL BEAM TO GIRDER OR
COLUMN CONNECTION DETAIL
SCALE: 3/4"=1'-0"
BEAM SIZE
W8, W10, W12
W16
W18
W21, W24
# OF BOLTS
7"
3 1/2"
/2
5/8" THK PLATE
HSS COLUMN
ROOF MOMENT CONNECTION DETAILS
MC-3
7"
3 1/2"
/2
5/8" THK PLATE
HSS COLUMN
5/16"
5/16"
2 SIDES
MC-2
3 1/2"
/2
CJP
CJP
5/8" THK PLATE
HSS COLUMN
5/16"
5/16"
MC-4
SCALE: 1"=1'-0"
(DIMENSIONS SHOWN ARE TYPICAL U.N.O.)
5/16"
5/16"
3 SIDES
3 1/2"
/2
5/8" THK PLATE
HSS COLUMN
5/16"
5/16"
3 SIDES
MC-1
7"
3 1/2"
/2
CJP
CJP
5/8" THK PLATE
HSS COLUMN
5/16"
5/16"
MC-6
4" 3" 3" 1 1/2"
/2
5/8" THK PLATE
HSS COLUMN
MC-5
4" 3" 3" 1 1/2"
5/16"
5/16"
3 SIDES
NOTE: DETAILS SHOWN ARE FOR BOTTOM PLATE MOMENT
CONNECTIONS. MOMENT CONNECTION TOP PLATES ARE ONE PIECE
WITH NO CUT-OUT FOR HSS COLUMN. COLUMNS TERMINATE AT
UNDERSIDE OF TOP PLATE MOMENT CONNECTION.
TOP PLATE (SEE NOTE)
TOP PLATE (SEE NOTE)
TOP PLATE (SEE NOTE)
TOP PLATE (SEE NOTE)
(CJP WELDS FOR BOTTOM PLATE
ONLY, SEE NOTE FOR TOP PLATE)
(CJP WELDS FOR BOTTOM PLATE
ONLY, SEE NOTE FOR TOP PLATE)
3 1/2"
/2
5/8" THK TOP &
BOT PLATE
HSS COLUMN
5/16"
5/16"
TYP
MC-7
5 3/4"
TOP PLATE
5/8" THK BOT
PLATE
3 1/2"
/2
5/8" THK TOP &
BOT PLATE
HSS COLUMN
5/16"
5/16"
TYP
MC-8
5 3/4"
TOP PLATE
5/8" THK BOT
PLATE
5/8" THK TOP &
BOT PLATE
C e tr o n ia R o a d S u it e n to w n
P
A
.4
.7
EMA-FIRE SCHOOL
DATE
T H
E C
O U
N T
Y O
F S
C H
U Y
L K
IL
L
M
N D
S T
R E
E T
P
O T
T S
V
IL
L E
P
A
DATE
Drawn By:
Y
K
IM
A R
C H
IT
E
C T
S
W
M a rk e t S tr e e t
P o tt s v ill e P
A
T
.6
.4 y k a a ia g m a il.
c o m
T H
E S
C H
U Y
L K
IL
L
C O
U N
T Y
E M
E R
G E
N C
Y S
E R
V
IC
E S
T R
A
IN
IN
G
F A
C
IL
IT
Y
Approved By:
Checked By:
DATE
CONTRACTOR SHALL BE
RESPONSIBLE FOR
VERIFICATION OF ALL
DIMENSIONS & EXISTING
CONDITIONS THAT WILL
AFFECT NEW WORK.
F
IR
E M
E N
'S R
O A
D
F R
A C
K V
IL
L
E
P A
S T
R U
C T
U R
A L
S T
E E
L D
E T
A
IL
S
JEB
MSR
MSR
S.7
@ < 4'-0" OPENINGS
@ 4'-0" TO 8'-0" OPENINGS
SCREWED JAMB WELDED JAMB
HEADER TO JAMB ASSEMBLY
TRACK SILL TO STUD ASSEMBLY
LOW HEADER TO STUD ASSEMBLY
WALL BRIDGING CHANNEL ASSEMBLY
STUD JAMB ASSEMBLY
ALTERNATIVESWALL ASSEMBLY AT FLOOR
WALL BUNDLE STUD
ASSEMBLY AT FLOOR BUNDLE STUD ASSEMBLY AT FLOOR
WALL INTERSECTION
BUNDLE STUD ASSEMBLY AT FLOOR
WALL CORNER
(2) 14 GA. JOIST HEADER
CONT. 14 GA. TRACK
WELDED JOINTS (TYP)
- SEE TYP. WALL
ASSEMBLY
FOR SIZE AND SPA.
CONT 14 GA. TRACK
- SEE CONNECTION
DETAILS
CONT HEADER - SEE
WALL SECTIONS
FOR LOCATION
CONT 14 GA. TRACK
- SEE CONNECTION
DETAILS
CONT 16 GA.
TRACK
- SEE CONNECTION
DETAILSTOP TRACK AND
HEADER
NOT FULLY SHOWN FOR
CLARITY OF ASSEMBLY
JAMB STUDS
L3x3x14 GA. CLIP
ANGLE
W/ (6) TEK SCREWS16 GA. TRACK
16 GA. STUD AND
TRACK
ASSEMBLY
16 GA. STUD SECTION
16 GA. STUD SECTION
16 GA. TRACK
16 GA. CR
CHANNEL
@ 4'-0" O.C. VERT.
16 GA. STUDS
W/ INDEXED
PUNCHOUTS
L3x3x14 GA. CLIP
ANGLE
W/ (4) TEK SCREWS
@ EACH STUD
GAUGE METAL FASTENERS TO BE #10 TEK SCREWS U.N.O.
GAUGE METAL FASTENERS TO BE 1/4
" TEK SCREWS U.N.O.
GAUGE METAL FASTENERS TO BE #10 TEK SCREWS U.N.O.
16 GA. STUDS
MIN. 16 GA. TRACK
AND CLIP ANGLE
MIN. # & OF SPACING OF TEK SCREWS REQUIRED PER ROW AT EACH
SIDE OF HEADER AND TRACK TO STUD CONNECTIONS:
12" DEPTH = 8 MIN. PER ROW @ 2" O.C. MAX. (16 TOTAL)
10" DEPTH = 6 MIN. PER ROW @ 2" O.C. MAX. (12 TOTAL)
8" DEPTH = 5 MIN. PER ROW @ 1 1/2" O.C. MAX. (10 TOTAL)
16 GA. JAMB STUDS
(2) @ 4'-0" MAX.
OPENING
(3) @ 4'-0" TO 8'-0" OPN'G
16 GA. TRACK
GAUGE METAL FASTENERS TO BE 1/4" TEK SCREWS @ 8" O.C. U.N.O.
3/4
" EPOXY ANCHOR
@ 32" O.C. - MIN. 10"
EMBED U.N.O.
WALL STUDS @ 16" O.C.
CONC FLOOR SLAB
3/4" EPOXY ANCHOR
@ 32" O.C. - MIN. 10"
EMBED U.N.O.
(4) 4SW14 STUDS
CONC FLOOR SLAB
3/4" EPOXY ANCHOR
EACH SIDE - MIN. 10"
EMBED U.N.O.
4SW14 STUDS
CONC FLOOR SLAB
3/4" EPOXY ANCHOR
EACH SIDE - MIN. 10"
EMBED U.N.O.
(4) 4SW14 STUDS
CONC FLOOR SLAB
1/8" 3"@8"
1/8" 3"@8"
TYP.
1/8" 1 1/2"
1/8" 1 1/2"
TYP. EA. STUD
1/8"
1/8"
1/8"
1/8"
TYP. EA. CLIP
1/8" 1 1/2"
1/8" 1 1/2"
TYP. EA. STUD
1/8" 3"@8"
1/8" 3"@8"
1/8"
TYP. EA. CLIP
1/8" 1 1/2"
1/8" 1 1/2"
TYP. EA. STUD
1/8" 3"@8"
1/8" 3"@8"
1/8" 3"@8"
1/8" 3"@8"
1/8" 1 1/2"
1/8" 1 1/2"
TYP. EA. STUD
1/8"
TYP. EA. CLIP
COLD FORMED HEADER TABLE
OPENING LENGTH HEADER SIZE JAMB SIZE
3'-0" TO 5'-0"
6'-0" TO 9'-0"
10-'-0" TO 12'-0"
(2) 600162-54 W/ 600T150-54 TOP AND BOTTOM
(2) 800162-54 W/ 600T150-54 TOP AND BOTTOM
(2) 1000162-54 W/ 600T200-54 TOP AND BOTTOM
(2) 600S162-54
(2) 600S162-54
(2) 600S162-68
NOTE:
HEADER AND JAMB SIZES PROVIDED ARE PRELIMINARY AND FOR BIDDING
PURPOSES ONLY. THE FINAL DESIGN IS THE RESPONSIBILITY OF THE
DESIGNATED COLD FORMED METAL FRAMING DESIGNER. REFER TO THE
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
C e tr o n ia R o a d S u it e n to w n
P
A
.4
.7
EMA-FIRE SCHOOL
DATE
T H
E C
O U
N T
Y O
F S
C H
U Y
L K
IL
L
M
N D
S T
R E
E T
P
O T
T S
V
IL
L E
P
A
DATE
Drawn By:
Y
K
IM
A R
C H
IT
E
C T
S
W
M a rk e t S tr e e t
P o tt s v ill e P
A
T
.6
.4 y k a a ia g m a il.
c o m
T H
E S
C H
U Y
L K
IL
L
C O
U N
T Y
E M
E R
G E
N C
Y S
E R
V
IC
E S
T R
A
IN
IN
G
F A
C
IL
IT
Y
Approved By:
Checked By:
DATE
CONTRACTOR SHALL BE
RESPONSIBLE FOR
VERIFICATION OF ALL
DIMENSIONS & EXISTING
CONDITIONS THAT WILL
AFFECT NEW WORK.
F
IR
E M
E N
'S R
O A
D
F R
A C
K V
IL
L
E
P A
C O
L D
F O
R M
E D
M E
T A
L F
R A
M
IN
G D
E T
A
IL
S
JEB
MSR
MSR
S.8
FLOOR SLAB
0' - 0"
LOW ROOF STEEL
14' - 1 1/2"
A
BOT OF FT'G
-4' - 0"
3' - 0"
T.O. PARAPET
16' - 0"
4 1/2"
8" 4"
1' - 0" 1' - 0" 1' - 0"
(4) #5 CONT REBAR
#5 REBAR @ 18" O.C.
RAMMED AGGREGATE
PIER (DESIGN BY
OTHERS)
2B STONE COMPATED
TO DEPTH
1/2" THK PRE-MOLDED
EXPANSION JOINT MATERIAL
600S162-54 (MIN) METAL
STUDS @ 16" O.C.
CONT.
DEFLECTION
TRACK
L3x3x1/4 DIAGONAL
BRACE @ 48" O.C.
L5x5x1/4x2'-0" LONG FASTENED
TO ROOF DECK (3 LOCATIONS
MIN. W/ 1/4" TEK SCREWS
BAR JOIST (SEE PLAN)
ROOF BEAM
(PER PLAN)
CONT L4x4x1/4 ANGLE
3/8" THK CONN PLATE
ROOF DECK
TAPERED ROOF INSULATION
(SEE ARCH DWGS)
1/4"
3 SIDES (TYP
EA END)
#4 REBAR
@ 12" O.C.
EF
REINF. CONCRETE
FLOOR SLAB (SEE PLAN)
ENTRANCE
CANOPY
11' - 1 1/2"
2B STONE BASE
COMPACTED TO
6" THICK
#4 REBAR
@ 12" O.C.
RIGID CONNECTION
@ 16" O.C.
(BY COLD FORMED
DESIGNER)
FLOOR SLAB
0' - 0"
LOW ROOF STEEL
14' - 1 1/2"
A
BOT OF FT'G
-4' - 0"
Aa
4 1/2"
REINF REBAR, SEE
FOOTING SCHEDULE
REINF REBAR, SEE
FOOTING SCHEDULE
RAMMED AGGREGATE
PIER (DESIGN BY
OTHERS)
2B STONE COMPATED
TO DEPTH
1/2" THK PRE-MOLDED
EXPANSION JOINT MATERIAL
RAMMED AGGREGATE
PIER (DESIGN BY
OTHERS)
2B STONE COMPATED
TO DEPTH
(4) #5 CONT REBAR
#5 REBAR @ 18" O.C.
ENTRANCE
CANOPY
11' - 1 1/2"
HSS COLUMN
SEE S.6 FOR BASEPLATE
ANCHORAGE DETAILS
REINFORCED CONCRETE
PIER. SEE SCHEDULE
EXTERIOR CONCRETE
SLAB. SEE SITE PLAN
1' - 0" 1' - 0" 1' - 0"
8" 4"
CONT.
DEFLECTION
TRACK
L3x3x1/4 DIAGONAL
BRACE @ 48" O.C.
L5x5x1/4x2'-0" LONG FASTENED
TO ROOF DECK (3 LOCATIONS
MIN. W/ 1/4" TEK SCREWS
BAR JOIST (SEE PLAN)
ROOF BEAM
(PER PLAN)
CONT L4x4x1/4 ANGLE
3/8" THK CONN PLATE
ROOF DECK
TAPERED ROOF INSULATION
(SEE ARCH DWGS)
1/4"
3 SIDES (TYP
EA END)
COLD FORMED STEEL
HEADERS. SEE SCHEDULE
CANOPY
BEAM (PER
PLAN)
600S162-54 (MIN) METAL
STUDS @ 16" O.C.
600S162-54 (MIN) METAL
STUDS @ 16" O.C.
3' - 0" 10' - 4 1/2"
CANTILEVER
CANOPY BEAM
ROOF DECK
TAPERED INSULATION
CANOPY
BEAM (PER
PLAN)
600S162-54 (MIN) METAL
STUDS @ 16" O.C.
#4 REBAR
@ 12" O.C.
#4 REBAR @ 12" O.C. EF
2B STONE BASE
COMPACTED TO
8" THICK
RIGID CONNECTION @ 16" O.C.
(BY COLD FORMED DESIGNER)
/8
4" MASONRY VENEER
6" CMU W/ ADJUSTABLE
MASONRY TIES @ 24" O.C.
C e tr o n ia R o a d S u it e n to w n
P
A
.4
.7
EMA-FIRE SCHOOL
DATE
T H
E C
O U
N T
Y O
F S
C H
U Y
L K
IL
L
M
N D
S T
R E
E T
P
O T
T S
V
IL
L E
P
A
DATE
Drawn By:
Y
K
IM
A R
C H
IT
E
C T
S
W
M a rk e t S tr e e t
P o tt s v ill e P
A
T
.6
.4 y k a a ia g m a il.
c o m
T H
E S
C H
U Y
L K
IL
L
C O
U N
T Y
E M
E R
G E
N C
Y S
E R
V
IC
E S
T R
A
IN
IN
G
F A
C
IL
IT
Y
Approved By:
Checked By:
DATE
CONTRACTOR SHALL BE
RESPONSIBLE FOR
VERIFICATION OF ALL
DIMENSIONS & EXISTING
CONDITIONS THAT WILL
AFFECT NEW WORK.
F
IR
E M
E N
'S R
O A
D
F R
A C
K V
IL
L
E
P A
W A
L L S
E C
T
IO
N S
JEB
MSR
MSR
S.9
01/09/25
3/4" = 1'-0"
WALL SECTION
3/4" = 1'-0"
WALL SECTION
8"
8"
8"
LOW ROOF STEEL
14' - 1 1/2"
BOT OF FT'G
-4' - 0"
T.O. PARAPET
16' - 0"
8" 4"
3' - 0"
4 1/2"
(4) #5 CONT REBAR
#5 REBAR @ 18" O.C.
RAMMED AGGREGATE
PIER (DESIGN BY
OTHERS)
2B STONE COMPATED
TO 8" DEPTH
1/2" THK PRE-MOLDED
EXPANSION JOINT MATERIAL
600S162-54 (MIN) METAL
STUDS @ 16" O.C.
CONT.
DEFLECTION
TRACK
L3x3x1/4 DIAGONAL
BRACE @ 48" O.C.
BAR JOIST
(SEE PLAN)
ROOF BEAM
(PER PLAN)
3/8" THK
CONN PLATE
ROOF
DECK
TAPERED ROOF INSULATION
(SEE ARCH DWGS)
1/4"
3 SIDES (TYP
EA END)
#4 REBAR @
12" O.C. EF
REINF. CONCRETE
FLOOR SLAB (SEE PLAN)
1' - 0" 1' - 0" 1' - 0"
3/8" THK CONN
PLATE
CONT HSS5x2 1/2x1/8
(LSH)
CONT TRACK
TOP & BOT
RIGID CONNECTION @ 16" O.C.
(BY COLD FORMED DESIGNER) 600S162-54 (MIN) METAL
STUDS @ 16" O.C.
2B STONE BASE
COMPACTED TO
8" THICK
3-12
3-12
#4 REBAR
@ 12" O.C.
FLOOR SLAB
0' - 0"
F
BOT OF FT'G
-4' - 0"
HIGH ROOF STEEL
18' - 5 1/2"
ROOF BEAM
(PER PLAN)
ROOF
DECK
TAPERED ROOF INSULATION
(SEE ARCH DWGS)
CONT TRACK
TOP & BOT
RIGID CONNECTION @ 16" O.C.
(BY COLD FORMED DESIGNER)
600S162-54 (MIN) METAL
STUDS @ 16" O.C.
CONT.
DEFLECTION
TRACK
L3x3x1/4 DIAGONAL
BRACE @ 48" O.C.
BAR JOIST
(SEE PLAN)3/8" THK
CONN PLATE 1/4"
3 SIDES (TYP
EA END)
3/8" THK CONN
PLATE
600S162-54 (MIN) METAL
STUDS @ 16" O.C.
BUILT-UP BOX HEADER.
SEE SCHEDULE ON S.8
1' - 0" 1' - 0" 1' - 0"
3' - 0"
9" 3"
1.95%
SLOPE - SEE
ARCH DWGS
(4) #5 CONT REBAR
#5 REBAR @ 18" O.C.
RAMMED AGGREGATE
PIER (DESIGN BY
OTHERS)
2B STONE COMPATED
TO 8" DEPTH
#4 REBAR @
12" O.C. EF 2B STONE BASE
COMPACTED TO
8" THICK
#4 BENT REBAR
@ 12" O.C.
#4 REBAR @ 12" O.C.
FLOOR SLAB
0' - 0"
LOW ROOF STEEL
14' - 1 1/2"
HSS COLUMN - SEE
PLAN AND SCHEDULE
RAMMED AGGREGATE
PIER (DESIGN BY
OTHERS)
2B STONE COMPATED
TO 8" DEPTH
1/2" THK PRE-MOLDED ISOLATION
JOINT MATERIAL
ROOF BEAM
(PER PLAN)
ROOF DECK
TAPERED ROOF INSULATION
(SEE ARCH DWGS)
REINF. CONCRETE
FLOOR SLAB (SEE PLAN)
ROOF BEAM
(PER PLAN)
CONT HSS5x2 1/2x1/8
(LSH)
3-12
3-12
MOMENT CONNECTION
SEE DETAILS ON S.7
COLUMN FOOTING -
SEE TYPICAL INTERIOR
FOOTING DETAIL ON S.6
C e tr o n ia R o a d S u it e n to w n
P
A
.4
.7
EMA-FIRE SCHOOL
DATE
T H
E C
O U
N T
Y O
F S
C H
U Y
L K
IL
L
M
N D
S T
R E
E T
P
O T
T S
V
IL
L E
P
A
DATE
Drawn By:
Y
K
IM
A R
C H
IT
E
C T
S
W
M a rk e t S tr e e t
P o tt s v ill e P
A
T
.6
.4 y k a a ia g m a il.
c o m
T H
E S
C H
U Y
L K
IL
L
C O
U N
T Y
E M
E R
G E
N C
Y S
E R
V
IC
E S
T R
A
IN
IN
G
F A
C
IL
IT
Y
Approved By:
Checked By:
DATE
CONTRACTOR SHALL BE
RESPONSIBLE FOR
VERIFICATION OF ALL
DIMENSIONS & EXISTING
CONDITIONS THAT WILL
AFFECT NEW WORK.
F
IR
E M
E N
'S R
O A
D
F R
A C
K V
IL
L
E
P A
W A
L L S
E C
T
IO
N S
JEB
MSR
MSR
S.10
01/09/25
3/4" = 1'-0"
WALL SECTION
3/4" = 1'-0"
WALL SECTION
3/4" = 1'-0"
WALL SECTION
BOT OF FT'G
-4' - 0"
H G
CANOPY STEEL
10' - 8 1/8"
RAMMED AGGREGATE
PIER (DESIGN BY
OTHERS)
2B STONE COMPATED
TO 8" DEPTH
HSS COLUMN - SEE ARCH.
FOR FINISH AND
ENCASEMENT
SEE S.6 FOR BASEPLATE
ANCHORAGE DETAILS
REINFORCED CONCRETE
PIER. SEE SCHEDULE
CANOPY BEAM
(PER PLAN)
REINF REBAR, SEE
FOOTING SCHEDULE
RAMMED AGGREGATE
PIER (DESIGN BY
OTHERS)
2B STONE COMPATED
TO 8" DEPTH
CANOPY BEAM
(PER PLAN)
HSS COLUMN - SEE ARCH.
FOR FINISH AND
ENCASEMENT
SEE S.6 FOR BASEPLATE
ANCHORAGE DETAILS
REINFORCED CONCRETE
PIER. SEE SCHEDULE
SEE CIVIL SITE PLANS FOR
FINISHED GROUND LINE
20' - 0"
REINF REBAR, SEE
FOOTING SCHEDULE
CONT TRACK
TOP & BOT
RIGID CONNECTION @ 16" O.C.
(BY COLD FORMED DESIGNER)
BUILT-UP BOX HEADER
(BY COLD FORMED
DESIGNER)
600S162-54 (MIN) METAL
STUDS @ 16" O.C.
ROOF
DECK
TAPERED ROOF INSULATION
(SEE ARCH DWGS)
6 5/8"
FLOOR SLAB
0' - 0"
BOT OF FT'G
-4' - 0"
HIGH ROOF STEEL
18' - 5 1/2"
ROOF BEAM
(PER PLAN)
ROOF
DECK
TAPERED ROOF INSULATION
(SEE ARCH DWGS)
CONT TRACK
TOP & BOT
RIGID CONNECTION @ 16" O.C.
(BY COLD FORMED DESIGNER)
600S162-54 (MIN) METAL
STUDS @ 16" O.C.
CONT.
DEFLECTION
TRACK
BAR JOIST
(SEE PLAN)
7 1/4"
#5 REBAR DOWEL
@ 48" O.C.
6" CMU
3000PSI SOLID GROUT FILL AT
ALL REINFORCEMENT CORES
FULL HEIGHT
CONT HORIZONTAL LADDER
TYPE JOINT REINF. - 9 GA.
GALV STEEL @ 16" O.C. VERT
(4) #5 CONT REBAR
#5 REBAR @ 18" O.C.
RAMMED AGGREGATE
PIER (DESIGN BY
OTHERS)
2B STONE COMPATED
TO 8" DEPTH
#4 REBAR @
12" O.C. EF 2B STONE BASE
COMPACTED TO
8" DEPTH
REINF. CONCRETE GARAGE
BAY FLOOR - SEE ARCH
DWGS FOR SLOPE
3' - 0"
MASONRY VENEER - SEE
ARCH DWG
ADJUSTABLE BRICK TIES
@ 16" O.C. E.W.
1' - 0" 1' - 0" 1' - 0"
9" 3"
600S162-54…
This is the start of the file's text. The full file is on GovTribe.