4-250523 ESTF Structural Plans.pdf

PDF 1 MB Posted

Attached to
Schuylkill County - Emergency Training Facility (0325-900015.01)
Solicitation number
US.251947
Issued by
Somerset County, Pennsylvania

About this file

Summary of ESTF Structural Plans

This file comprises structural plans for the Schuylkill County Emergency Training Facility construction project in Pennsylvania, which will be procured through sealed competitive bidding managed by the Schuylkill County Controller. The project is divided into four separate prime contracts: General Construction, Plumbing Construction, HVAC Construction, and Electrical Construction. Sealed bids will be received online via the PennBid Program until Wednesday, October 21, 2026, at 9:00 AM, with bid results posted online following the Board of Commissioners meeting. The tentative award date is Wednesday, October 28, 2026. All bidding documents are available at no cost through the PennBid portal at http://PennBid.bonfirehub.com. Bidders requiring assistance with the PennBid platform may contact support via email at info@pennbid.net or by phone at 610-693-4769.

Each bid submission must include a certified check, bank draft, or satisfactory Bid Bond payable to Schuylkill County in the amount of 10 percent of the total bid; money orders are not acceptable. The successful bidder will be required to provide Performance and Payment Bonds each equal to 100 percent of the contract price with a corporate surety approved by the county. Davis-Bacon wage rates apply to all contracts. Non-discrimination requirements prohibit discrimination based on race, age, color, religion, sex, national origin, or disability. The county reserves the right to waive informalities or reject any or all bids in its best interest.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONCRETE

GENERAL NOTES

DESIGN LOADS

2018 INTERNATIONAL BUILDING CODE

LIVE LOADS

ROOF LIVE LOAD = 20 PSF

FLOOR LIVE LOADS

SLAB ON GRADE TYPICAL DESIGN LOAD

8" SLAB (GARAGE)

MAXIMUM AXLE REACTION = 15,600 LB

SNOW LOADS

GROUND SNOW LOAD = 40 PSF

FLAT ROOF SNOW LOAD, Pf = 44 PSF

SNOW EXPOSURE FACTOR, Ce = 1.0

SNOW LOAD IMPORTANCE FACTOR, Is = 1.2

THERMAL FACTOR, Ct

WIND LOADS

Vult = 125 MPH

RISK CATEGORY = IV

INTERNAL PRESSURE COEFFICIENT = ± 0.18

EXPOSURE CATEGORY = C

SEISMIC

RISK CATEGORY = IV

IMPORTANCE FACTOR, Ie = 1.50

MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS

SS = 0.150 g

S1 = 0.041 g

SITE CLASS = D

DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS

SDS = 0.240 g

SD1 = 0.098 g

SEISMIC RESPONSE MODIFICATION FACTOR, R = 3 (STEEL SYSTEM NOT SPECIFICALLY

DETAILED FOR SEISMIC RESISTANCE)

DESIGN BASE SHEAR = 7.92 KIPS

SEISMIC RESPONSE COEFFICIENT, CS = 0.08

ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE

SEISMIC DESIGN CATEGORY = B

STRUCTURAL SYMBOLS

DENOTES FOOTING SIZE AND ELEVATION

DENOTES PIER SIZE AND ELEVATION

STEP DENOTES FOUNDATION STEP

F# (###.##)

P# [###.##]

1. MANUFACTURERS OF OPEN WEB STEEL JOISTS AND JOIST GIRDERS SHALL BE MEMBERS OF THE

STEEL JOIST INSTITUTE. OPEN WEB STEEL JOISTS SHALL BE DESIGNED, FABRICATED AND

ERECTED IN ACCORDANCE WITH PROVISIONS FOUND IN THE STEEL JOIST INSTITUTE

PUBLICATION, STANDARD SPECIFICATIONS, LOAD TABLES AND WEIGHT TABLES FOR STEEL

JOISTS AND JOIST GIRDERS, LATEST EDITION.

2. WHERE NOTED, OPEN WEB STEEL JOISTS AND JOIST GIRDERS SHALL BE DESIGNED FOR

ADDITIONAL CONCENTRATED LOADS AND MOMENTS AS WELL AS FOR NONSTANDARD MEMBER

GEOMETRIES AS INDICATED ON DRAWINGS AND LOADING DIAGRAMS. CONTRACTOR SHALL

SUBMIT DESIGN CALCULATIONS FOR OPEN WEB STEEL JOISTS AND JOIST GIRDERS DESIGNED

TO RESIST CONCENTRATED LOADS AND MOMENTS.

3. OPEN WEB STEEL JOISTS AND JOIST GIRDERS SHALL RECEIVE ONE SHOP COAT OF PRIMER

PAINT, U.N.O.

4. MODIFY JOIST SHOES, PANEL POINT SPACING, MEMBER CROSS-SECTIONS AND GEOMETRY AS

INDICATED ON ARCHITECTURAL AND STRUCTURAL DRAWINGS TO CONFIRM TO DESIGN

REQUIREMENTS.

5. BRIDGING SHALL MEET THE MINIMUM REQUIREMENTS OF SJI, U.N.O. HORIZONTAL BRIDGING

SHALL BE CONTINUOUS TOP AND BOTTOM, ANCHORED AT EACH END AND WELDED AT SPLICE

LOCATIONS AND TO EACH JOIST. DIAGONAL BRIDGING SHALL BE BOLTED TO EACH JOIST AND

CLAMPED OR WELDED PER REQUIREMENT OF SJI.

6. CONCENTRATED LOADS DUE TO HANGERS, HEADERS, MECHANICAL EQUIPMENT ETC. SHALL BE

SUPPORTED ONLY AT JOIST PANEL POINTS WHERE CONCENTRATED LOADS SUPPORT DO NOT

ALIGN WITH JOIST PANEL POINTS, CONTRACTOR SHALL CONTACT THE ENGINEER AND PROVIDE

SUPPLEMENTAL MEMBERS AS REQUIRED.

1. METAL DECK SHALL BE AS NOTED ON DRAWINGS, FABRICATED AND ERECTED IN ACCORDANCE WITH THE STEEL DECK INSTITUTE, “SDI SPECIFICATIONS, FOR STEEL COMPOSITE DECK, FORM

DECK AND ROOF DECK".

2. THE CONTRACTOR SHALL FURNISH ALL ACCESSORIES INCLUDING CLOSURES, “Z” CLOSURES, COLUMN CLOSURES, SCREED ANGLES AND GIRDER FILLERS, AS REQUIRED.

3. ROOF DECK SHALL RECEIVE ONE SHOP COAT OF PRIMER PAINT.

ROOF DECK SPECIFICATION:

VULCRAFT 1-1/2" TYPE B 18 GAUGE WIDE RIB DECK

ROOF DECK ATTACHMENT:

5/8" PUDDLE WELDS, 36/4 SUPPORT PATTERN WITH #10 TEK SCREW SIDE LAP

CONNECTION

4. CONTRACTOR SHALL PROVIDE PUBLISHED MANUFACTURER'S DATA AND INDEPENDENTLY

CERTIFIED TEST DATA VERIFYING THE SPECIFIED DECK REQUIREMENTS TO THE

ARCHITECT/ENGINEER FOR REVIEW. PROVIDE ENGINEERED AND CHECKED SHOP DRAWINGS

INDICATING LOCATION, GAGE AND SIZE OF EACH PIECE OF DECKING. SHOP DRAWINGS SHALL

CLEARLY SHOW WELDING DETAILS TO CONNECT METAL DECK WITH STRUCTURAL FRAMING AND

SIDE LAP CONNECTION DETAILS.

5. METAL DECK SHALL BE WELDED TO STRUCTURAL STEEL BY WELDERS QUALIFIED FOR THE

PROCEDURE USED, CONSISTENT WITH ANSI/AWS D1.3, “STRUCTURAL WELDING CODE-SHEET

STEEL.” CONTRACTOR SHALL ESTABLISH A WELDING PROCEDURE FOR CONNECTING STEEL

DECKING TO THE STRUCTURAL STEEL. PRIOR TO STEEL DECK ERECTION, EACH WELDER SHALL

BE QUALIFIED USING THE ESTABLISHED PROCEDURE AS WITNESSED BY THE OWNER'S TESTING

AGENCY.

6. NO LOADS SHALL BE HUNG DIRECTLY ABOVE FROM ROOF DECK WITH THE EXCEPTION OF

TERTIARY FIRE PROTECTION PIPING BRANCHES. ALL OTHER HANGERS FOR CEILINGS,

DUCTWORK, ELECTRICAL CONDUIT, PIPING, PRIMARY FIRE PROTECTION PIPING, ETC., SHALL BE

HUNG DIRECTLY FROM STRUCTURAL STEEL WORK OR SUPPLEMENTARY MEMBERS CONNECTED

BETWEEN STRUCTURAL STEEL.

7. DECK INSTALLATION SHALL BE CONTINUOUS OVER AT LEAST THREE SPANS OF FRAMES.

MASONRY NOTES

= 1.0

DEAD LOADS

ROOF DEAD LOAD = 20 PSF

OPEN WEB STEEL JOISTS AND JOIST GIRDERS

METAL DECK

1. ALL WORK SHOWN ON THESE DRAWINGS HAS BEEN DESIGNED IN ACCORDANCE WITH THE

STRUCTURAL REQUIREMENTS OF THE "2018 INTERNATIONAL BUILDING CODE" (IBC) AND TO ALL

OTHER APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS.

2. JOBSITE SAFETY AND CONSTRUCTION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE

CONTRACTOR.

3. THE CONTRACTOR SHALL COORDINATE OPENINGS, SLEEVES, CONCRETE HOUSEKEEPING PADS, INSERTS, AND DEPRESSIONS SHOWN ON THE MEP, ARCHITECTURAL, AND STRUCTURAL

DRAWINGS.

4. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE MEP AND SITE

DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE CONTRACTOR'S

RESPONSIBILITY TO NOTIFY THE ENGINEER PRIOR TO PERFORMING THE WORK.

5. THE CONTRACTOR SHALL VERIFY ALL EXISTING BUILDING INFORMATION SHOWN (DIMENSIONS, EXISTING CONDITIONS, ELEVATIONS, ETC.) AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES

PRIOR TO FABRICATION OF ANY STRUCTURAL COMPONENT. FAILURE TO NOTIFY ENGINEER OF

UNSATISFACTORY CONDITIONS CONSTITUTES ACCEPTANCE OF UNSATISFACTORY CONDITIONS.

6. THE STABILITY OF THE STRUCTURE PRIOR TO COMPLETION IS SOLELY THE RESPONSIBILITY OF

THE CONTRACTOR. THIS RESPONSIBILITY EXTENDS TO ALL RELATED ASPECTS OF THE

CONSTRUCTION ACTIVITY INCLUDING, BUT NOT LIMITED TO, ERECTION METHODS, ERECTION

SEQUENCE, TEMPORARY BRACING, FORMS, SHORING, USE OF EQUIPMENT AND SIMILAR

CONSTRUCTION PROCEDURES.

7. IF THE EXISTING FIELD CONDITIONS DO NOT PERMIT THE INSTALLATION OF THE WORK IN

ACCORDANCE WITH THE DETAILS SHOWN, THE CONTRACTOR SHALL NOTIFY THE

ARCHITECT/ENGINEER IMMEDIATELY AND PROVIDE A SKETCH OF THE CONDITION WITH HIS

PROPOSED MODIFICATION OF THE DETAILS GIVEN ON THE CONTRACT DOCUMENTS. DO NOT

COMMENCE WORK UNTIL CONDITION IS RESOLVED AND MODIFICATION IS APPROVED BY THE

ENGINEER.

8. SHOP DRAWINGS FOR ALL STRUCTURAL MATERIALS TO BE SUBMITTED TO ENGINEER FOR REVIEW PRIOR TO THE START OF FABRICATION OR COMMENCEMENT OF WORK. REVIEW PERIOD SHALL BE

A MINIMUM OF TWO (2) WEEKS.

9. SHOP DRAWINGS SHALL BEAR THE CONTRACTOR'S STAMP OF APPROVAL WHICH SHALL

CONSTITUTE CERTIFICATION THAT THE CONTRACTOR HAS VERIFIED ALL CONSTRUCTION

CRITERIA, MATERIALS, AND SIMILAR DATA AND HAS CHECKED EACH DRAWING FOR

COMPLETENESS, COORDINATION, AND COMPLIANCE WITH THE CONTRACT DOCUMENTS.

10. THE STRUCTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL STRUCTURAL FEATURES,

UNLESS NOTED OTHERWISE.

11. CONTRACTOR TO COMPLY WITH MINIMUM INSPECTION REQUIREMENTS AS PER IBC CHAPTER 17.

12. CONSTRUCTION LOADS SHALL NOT EXCEED DESIGN LOADS AND SHALL NOT BE LOADED UNTIL

CONCRETE HAS REACHED 75% OF SPECIFIED COMPRESSIVE STRENGTH.

1. CONCRETE SHALL BE DESIGNED AND DETAILED IN ACCORDANCE WITH THE BUILDING CODE

REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318-14) AND CONSTRUCTED IN

ACCORDANCE WITH THE CRSI MANUAL OF STANDARD PRACTICE.

2. CONCRETE SHALL CONFORM WITH "SPECIFICATIONS FOR STRUCTURAL CONCRETE" (ACI 301)

AND AS NOTED BELOW.

3. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE 28-DAY STRENGTH AS FOLLOWS:

TYPE f'c MIN (PSI)

FOOTINGS 3000

PIERS 3000

SLABS ON GRADE 4000

SLABS ON METAL DECK 4000

4. AIR ENTRAINMENT SHALL BE 6% IN ALL EXPOSED CONCRETE.

5. MAXIMUM WATER/CEMENT RATIOS:

A. FOUNDATIONS 0.45

6. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (144 PCF +) WITH ALL CEMENT

CONFORMING TO ASTM C150, TYPE I. MAXIMUM AGGREGATE SIZE SHALL BE 1-1/2" FOR

FOOTINGS AND 3/4" FOR WALLS AND SLABS, CONFORMING TO ASTM C33.

7. LEVELING GROUT SHALL BE NON-SHRINK, NON-METALLIC TYPE, FACTORY PRE-MIXED GROUT IN

ACCORDANCE WITH CE-CRD-C621 OR ASTM C109, WITH A MINIMUM COMPRESSIVE 28-DAY

STRENGTH OF 5,000 PSI.

8. REINFORCING STEEL: ASTM A615 GRADE 60, DEFORMED

9. REINFORCING STEEL CLEAR COVER SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE:

A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 4"

B. CONCRETE EXPOSED TO EARTH OR WEATHER:

#6 BARS AND LARGER: 2"

#5 BARS AND SMALLER: 1-1/2"

C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:

SLABS, WALLS, JOISTS

#14 BARS AND #18 BARS: 1-1/2"

#11 BARS AND SMALLER: 3/4"

BEAMS AND COLUMNS, PRIMARY REINFORCEMENT, TIES, STIRRUPS, OR SPIRALS: 1-1/2"

10. SUBMIT TO ENGINEER REINFORCING STEEL SHOP DRAWINGS FOR APPROVAL AND MIX DESIGNS

FOR REVIEW PRIOR TO PLACING ANY CONCRETE.

11. PLACING OF CONCRETE SHALL NOT START UNTIL THE PLACEMENT OF REINFORCING HAS BEEN

APPROVED BY THE INSPECTION AGENCY. EPOXY ADHESIVE SHALL BE USED WHERE DOWELS

ARE TO BE INSTALLED INTO EXISTING CONCRETE.

12. PRIOR TO PLACING CONCRETE, THE CONTRACTOR SHALL SUBMIT FOR REVIEW BY THE

STRUCTURAL ENGINEER, CONCRETE MIX DESIGNS PREPARED IN ACCORDANCE WITH THE

REQUIREMENTS INDICATED IN THE GENERAL NOTES..

13. EARLY DRYING OUT OF CONCRETE, ESPECIALLY DURING THE FIRST 24 HOURS, SHALL BE

CAREFULLY GUARDED AGAINST. ALL SURFACES SHALL BE MOIST CURED OR PROTECTED USING

A MEMBRANE CURING AGENT APPLIED AS SOON AS FORMS ARE BRANE CURING AGENT IS USED,

EXERCISE CARE NOT TO DAMAGE COATING.

14. COLD WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI-306R. HOT WEATHER

CONCRETING SHALL BE IN ACCORDANCE WITH ACI-305R.

15. THROUGHOUT CONSTRUCTION, THE CONCRETE WORK SHALL BE ADEQUATELY PROTECTED

AGAINST DAMAGE DUE TO EXCESSIVE LOADING, CONSTRUCTION EQUIPMENT, MATERIALS OR

METHODS, ICE, RAIN, SNOW, EXCESSIVE HEAT, AND FREEZING TEMPERATURES.

1. MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS

FOR MASONRY STRUCTURES (ACI 530-13/TMS 402-13) AND SHALL BE CONSTRUCTED IN

ACCORDANCE WITH THE SPECIFICATIONS FOR MASONRY STRUCTURES (ACI 530.1-13/TMS 602-13), EXCEPT WHERE OTHERWISE MODIFIED BY THESE GENERAL NOTES.

2. MORTAR SHALL CONFORM TO ASTM C270, TYPE M AT ALL LOAD BEARING WALLS; TYPE S AT

INTERIOR PARTITIONS, PARAPETS, AND NON-LOAD BEARING WALLS. ALL PORTLAND CEMENT

SHALL CONFORM TO ASTM C150, TYPE I. LIME SHALL CONFORM TO ASTM C207 AND MASONRY

CEMENT SHALL CONFORM TO ASTM C91.

3. GROUT SHALL CONFORM TO ASTM C476 AND SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE

STRENGTH OF 3000 PSI. SLUMP OF GROUT SHALL BE 8 TO 10 INCHES AND THE MAXIMUM

AGGREGATE SIZE SHALL BE 3/8" (AGGREGATE GRADED TO PRODUCE FINE GROUT IN

CONFORMANCE WITH ASTM C476 AND C404).

4. SOLID AND HOLLOW LOAD BEARING UNITS PER ASTM C90, TYPE N-1, AS REQUIRED TO PROVIDE 28 DAY COMPRESSIVE STRENGTH, f'm SHALL BE 2800PSI.

5. MINIMUM 28-DAY COMPRESSIVE STRENGTH OF MASONRY, f'm SHALL BE 2800 PSI, UNLESS NOTED

OTHERWISE. FULL BED AND HEAD JOINTS SHALL BE PROVIDED.

6. HORIZONTAL JOINT REINFORCING: ASTM A82; 9-GAGE LADDER-TYPE, GALVANIZED.

7. DEFORMED BAR REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 60 AND SHALL BE

FULL HEIGHT OF WALLS UNLESS OTHERWISE NOTED. PROVIDE BAR SPACERS AND POSITIONERS

AS REQUIRED TO PROPERLY LOCATE AND STABILIZE REINFORCING DURING GROUTING

OPERATIONS. GROUT ALL REINFORCED CELLS SOLID WITH GROUT.

8. BUILD AND TEST MASONRY PRISMS DURING CONSTRUCTION TO VERIFY f'm FOR EACH CLASS OF

MASONRY CONSTRUCTION. PRISM TESTS SHALL BE IN ACCORDANCE WITH ASTM E447, METHOD

B.

9. HOLLOW CONCRETE UNITS BELOW GRADE AND SLAB ON GRADE SHALL BE NORMAL WEIGHT AND

HAVE ALL CELLS GROUTED SOLID.

10. PROVIDE AND INSTALL TEMPORARY BRACING REQUIRED INSURING STABILITY OF ALL WALLS

DURING CONSTRUCTION AND UNTIL ERECTION OF ATTACHED STRUCTURAL FRAMING IS

COMPLETED.

11. PROVIDE GALVANIZED HORIZONTAL JOINT REINFORCEMENT IN ALL WALLS AND PARTITIONS AT

16" O.C. UNLESS OTHERWISE SHOWN OR NOTED. PROVIDE ONE (1) PIECE PREFABRICATED

UNITS AT 8" O.C. AT ALL WALL CORNERS AND INTERSECTIONS.

12. LAP SPLICES FOR DEFORMED REINFORCING BARS USED IN MASONRY CONSTRUCTION SHALL BE

50 BAR DIAMETERS.

13. SUBMIT GROUT MIX DESIGN AND MASONRY UNIT CERTIFICATIONS TO THE PRIME PROFESSIONAL

FOR REVIEW.

14. GROUT PLACEMENT SHALL NOT START UNTIL THE PLACEMENT OF REINFORCING HAS BEEN

APPROVED BY THE INSPECTION AGENCY.

15. FILL ALL CELLS IN TOP THREE (3) COURSES BELOW FINISHED FLOOR, CMU LINTELS, BOND

BEAMS, AND BEAM BEARINGS AND CELLS WITH REINFORCEMENT FULL HEIGHT SOLID WITH

GROUT.

16. ALLOW GROUT IN REINFORCED CMU WALLS TO CURE A MINIMUM OF 48 HOURS BEFORE

IMPOSING CONCENTRATED OR OTHER LOADS FROM ABOVE.

17. PROVIDE MASONRY ANCHORS AT 16" O.C. SET ON COURSING AND ATTACHED TO ALL BEAMS, COLUMNS, PARTITIONS, AND WALLS ABUTTING OR EMBEDDED IN MASONRY UNLESS NOTED

OTHERWISE ON PRIME PROFESSIONAL AND STRUCTURAL DRAWINGS.

18. PROVIDE BOND BEAMS WITH TWO (2) #5 HORIZONTAL REINFORCEMENT CONTINUOUS IN ALL

MASONRY WALLS AT EACH FRAMING LEVEL. PROVIDE A MINIMUM OF TWO (2) #4 BARS AT THE

ENDS OF ALL WALLS AND ON EACH SIDE OF EACH OPENING.

19. ALL PIERS AND PARTITIONS SHALL BE BONDED OR ANCHORED TO ADJACENT MASONRY WALLS.

PROVIDE TIES TO ADJACENT FLOOR AND ROOF CONSTRUCTION IN ACCORDANCE WITH DETAILS

ON DRAWINGS.

20. THE CONTRACTOR SHALL VERIFY ALL OPENINGS BELOW LINTELS INDICATED ARE ADEQUATE TO

ACCEPT DOORFRAMES, LOUVERS, ETC. AS SHOWN ON THE PRIME PROFESSIONAL AND

MECHANICAL DRAWINGS. NOTIFY THE PRIME PROFESSIONAL AND STRUCTURAL ENGINEER OF

ANY DISCREPANCIES PRIOR TO LINTEL INSTALLATION.

21. NO OPENINGS SHALL BE PLACED ABOVE ANY LINTEL WITHIN A HEIGHT LESS THAN OR EQUAL TO

THE WIDTH OF THE CLEAR OPENING BELOW THE LINTEL, UNLESS SPECIFICALLY SHOWN OR

APPROVED BY THE STRUCTURAL ENGINEER.

22. ALL MASONRY WORK TO BE EXECUTED IN COLD WEATHER SHALL BE IN CONFORMANCE WITH

THE RECOMMENDATIONS FOR COLD WEATHER CONSTRUCTION FOUND IN THE BUILDING CODE

REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-13/TMS 402-13) AND SHALL BE

CONSTRUCTED IN ACCORDANCE WITH THE SPECIFICATIONS FOR MASONRY STRUCTURES (ACI

530.1-13/TMS 602-13) WITH THE FOLLOWING ADDITIONS: FOR ALL CONDITIONS WHEN

TEMPERATURES FALL BELOW 40 DEGREES F, THE TEMPERATURE OF THE NEWLY LAID MASONRY

OR NEWLY GROUTED MASONRY SHALL BE MAINTAINED ABOVE 32 DEGREES F FOR A MINIMUM OF

24 HOURS USING THE METHODS DESCRIBED IN ACI 530.1.

23. THE TESTING AND INSPECTION AGENCY SHALL MONITOR THE PROPORTIONING, MIXING, AND

CONSISTENCY OF MORTAR AND GROUT; THE PLACEMENT OF MORTAR, GROUT, AND MASONRY

UNITS; AND THE PLACEMENT OF REINFORCING STEEL FOR COMPLIANCE WITH THE CONTRACT

DOCUMENTS.

24. THE CONTRACTOR SHALL PREPARE ONE (1) SET OF PRISMS FOR TESTING AT SEVEN (7) DAYS AND ONE (1) SET FOR TESTING AT 28 DAYS. TESTS ARE TO BE CONDUCTED BY THE INSPECTION AND TESTING AGENCY FOR EACH 3,000 SQUARE FEET OF WALL INSTALLED, BUT NOT LESS THAN

TWO (2) TESTS.

25. ALL WALL SECTIONS AND PIERS LESS THAN TWO SQUARE FEET IN CROSS-SECTIONAL AREA

SHALL BE FULLY GROUTED.

26. PROVIDE VERTICAL MASONRY CONTROL JOINTS AT MAXIMUM 25'-0" ON CENTER UNLESS

DETAILED ON PRIME PROFESSIONAL DRAWINGS, COORDINATE LOCATIONS WITH ARCHITECT.

FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO "THE MANUAL OF

STEEL CONSTRUCTION - (15TH EDITION)", AMERICAN INSTITUTE OF STEEL CONSTRUCTION,

INCLUDING SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, SPECIFICATION FOR

STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS, AND AISC CODE OF STANDARD

PRACTICE.

1. MATERIALS:

STRUCTURAL STEEL ASTM A992

PLATES, ANGLES, CHANNELS ASTM A36 (MIN)

STRUCTURAL STEEL TUBING - SQUARE ASTM A 500, GRADE C

HEADED ANCHOR RODS F1554, GRADE 36

2. ALL BOLTED CONNECTIONS SHALL BE WITH ASTM A325 HIGH STRENGTH BOLTS 3/4"

MINIMUM DIAMETER, UNLESS NOTED OTHERWISE.

3. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS AND SHALL CONFORM TO

"STRUCTURAL WELDING CODE ANSI/AWS D1.1-2011" AMERICAN WELDING SOCIETY.

4. ALL BOLTED CONNECTIONS ON WIND BRACING MEMBERS AND COLUMNS SHALL BE SLIP

CRITICAL CONNECTIONS.

5. WELDING ELECTRODES SHALL BE E70XX FOR MANUAL ARC WELDING AND F7X-EXXX FOR

SUBMERGED ARC WELDING. ALL WELDERS SHALL BE CERTIFIED BY THE AWS. MINIMUM

WELD SIZE SHALL BE 3/16" UNLESS NOTED OTHERWISE.

6. CUTS, HOLES, COPING, ETC. REQUIRED FOR OTHER TRADES OR FIELD CONDITIONS SHALL

BE SHOWN ON THE SHOP DRAWINGS AND MADE IN THE SHOP. CUTTING OR BURNING OF

MAIN STRUCTURAL MEMBERS IN THE FIELD WILL NOT BE PERMITTED.

7. STEEL MEMBERS SHOWN ON PLAN SHALL BE EQUALLY SPACED UNLESS NOTED

OTHERWISE.

8. THE GENERAL CONTRACTOR AND STEEL ERECTOR SHALL NOTIFY THE STRUCTURAL

ENGINEER OF ANY FABRICATION OR ERECTION ERRORS OR DEVIATIONS AND RECEIVE

WRITTEN APPROVAL BEFORE ANY FIELD CORRECTIONS ARE MADE.

9. ALTERNATE CONNECTION DETAILS MAY BE USED IF SUCH DETAILS ARE SUBMITTED TO THE

ENGINEER FOR REVIEW AND APPROVAL. HOWEVER, THE ENGINEER SHALL BE THE SOLE

JUDGE OF ACCEPTANCE AND THE CONTRACTOR'S BID SHALL ANTICIPATE THE USE OF

THOSE DETAILS SHOWN ON THE DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR THE

DESIGN OF SUCH ALTERNATE DETAILS WHICH HE PROPOSES.

10. MAIN SUPPORT MEMBERS FOR THE METAL DECK ARE SHOWN. DURING PREPARATION,

SUBMISSION, AND REVIEW OF SHOP DRAWINGS, ANY ADDITIONAL ANGLES OR

MISCELLANEOUS ATTACHMENT DETAILS REQUIRED TO SUPPORT THE METAL DECK AT THE

REQUIRED ELEVATION SHALL BE PROVIDED BY THE STRUCTURAL STEEL CONTRACTOR.

11. ALL STEEL SHALL BE PAINTED WITH SHOP STANDARD PRIMER UNLESS NOTED OTHERWISE.

12. ALL EXTERIOR EXPOSED STRUCTURAL STEEL SHALL BE HOT-DIPPED GALVANIZED PER

ASTM A123.

13. FIELD WELDED SURFACES WITHIN FOUR (4) INCHES OF WELD SHALL BE CLEANED AND

GROUND SMOOTH. AFTER WELDING COAT THE EXPOSED AREA WITH APPROPRIATE

PRIMER/PAINTS AS SPECIFIED.

14. GUYS AND OTHER BRACING REQUIRED TO PROVIDE LATERAL STABILITY TO STEEL FRAME

SHALL BE ADEQUATELY SIZED AND ANCHORED. THIS BRACING SHALL REMAIN UNTIL

PERMANENT BRACING ELEMENTS AND ATTACHED CONSTRUCTION IS INSTALLED.

15. VISUALLY INSPECT ALL FILLET WELDS.

16. FIELD TEST BOLTED CONNECTIONS AND SHEAR STUDS IN ACCORDANCE WITH AISC.

17. ALL STEEL SHALL BE THOROUGHLY CLEANED BY POWER TOOL CLEANING PRIOR TO

PAINTING. ALL ARCHITECTURALLY EXPOSED STRUCTURAL STEEL SHALL BE CLEANED WITH

COMMERCIAL BLAST CLEANING.

18. ALL DISSIMILAR METALS SHALL BE TREATED OR PROPERLY SEPARATED TO PREVENT

GALVANIC AND/OR CORROSIVE EFFECTS.

19. ALL CONNECTIONS SHALL BE SYMMETRICAL ABOUT THE AXIS OF THE MEMBER

CONNECTED. PROVIDE ONLY ONE GRADE OF BOLT FOR EACH BOLT DIAMETER TO BE USED

IN THE CONNECTIONS. DO NOT MIX GRADE OF BOLTS.

20. THE CONTRACTOR SHALL PREPARE STRUCTURAL STEEL ERECTION AND SHOP DRAWINGS

TO BE SUBMITTED TO THE ENGINEER FOR REVIEW.

STRUCTURAL STEEL

SPECIAL INSPECTIONS:

THE FOLLOWING ITEMS REQUIRE SPECIAL INSPECTION AND TESTING PER IBC 2018 SECTION 1705.

THE INSPECTION SHALL BE PERFORMED BY A SPECIAL INSPECTOR CERTIFIED TO PERFORM THE

TYPES OF INSPECTIONS AND TESTS SPECIFIED.

ITEM DESCRIPTION IBC SECTION

STRUCTURAL STEEL AND WELDING 1705.2 AND 1705.2.1

HIGH STRENGTH BOLTING 1705.2 AND 1705.2.1

COLD-FORMED STEEL DECK 1705.2.2

SOILS 1705.6 AND TABLE 1705.6

CONCRETE AND REINFORCING STEEL TABLE 1705.3

COLD-FORMED STEEL FRAMING 1705.11.2

COMPONENTS AND CLADDING WIND LOADS (PSF)

AREA ZONE 4 (+) ZONE 4 (-) ZONE 5 (+) ZONE 5 (-)

< 5 SF 31.70 -34.34 31.70 -42.27

> 20 SF 30.30 -32.94 30.30 -39.46

> 100 SF 27.04 -29.68 27.04 -32.94

NOTE: WIND LOADS PROVIDED ARE AT THE ULTIMATE (LRFD) LEVEL.

FOUNDATION NOTES:

1. ALLOWABLE SOIL BEARING PRESSURE = 3,000 PSF (AFTER GROUND IMPROVEMENTS)

2. PROVIDE RAMMED AGGREGATE PIERS (DELEGATED DESIGN BY OTHERS) AT EACH COLUMN

FOOTING LOCATION AND AS REQUIRED ALONG WALL FOOTINGS. LOADS SPECIFIED ON THE

FOUNDATION PLAN ARE ASD (SERVICE-LEVEL UNFACTORED). REFER TO THE GEOTECHNICAL

REPORT BY BARRY ISSETT AND ASSOCIATES DATED NOVEMBER 25TH, 2024 AND SPECIFICATION

"30100 - AGGREGATE PIERS" FOR ADDITIONAL INFORMATION.

3. MAXIMUM WALL FOOTING LOAD = 1.5 KIPS PER FOOT (SERVICE LEVEL)

4. BOTTOM OF FOUNDATIONS ALONG BUILDING PERIMETER, UNHEATED AREAS, AND FROST WALLS

SHALL BE PLACED A MINIMUM OF 48 INCHES BELOW THE FINAL EXTERIOR GRADE FOR

PROTECTION AGAINST FROST UPLIFT.

5. THE CONTRACTOR SHALL BE SOLELY RESPONSBILE FOR THE STABILITY OF ALL EXCAVATED

SLOPES AND SHALL PROVIDE TEMPORARY SHEETING/SHORING AS REQUIRED THAT CONFORMS

TO MINIMUM OSHA REQUIREMENTS.

6. THE GEOTECHNICAL ENGINEER SHALL APPROVE ALL BEARING STATA PRIOR TO PLACEMENT OF

ANY CONCRETE FOOTING.

C e tr o n ia R o a d S u it e

A lle n to w n

P

A

.4

.7

EMA-FIRE SCHOOL

DATE

T H

E C

O U

N T

Y O

F S

C H

U Y

L K

IL

L

M

N D

S T

R E

E T

P

O T

T S

V

IL

L E

P

A

DATE

Drawn By:

Y

K

IM

A R

C H

IT

E

C T

S

W

M a rk e t S tr e e t

P o tt s v ill e P

A

T

.6

.4 y k a a ia g m a il.

c o m

T H

E S

C H

U Y

L K

IL

L

C O

U N

T Y

E M

E R

G E

N C

Y S

E R

V

IC

E S

T R

A

IN

IN

G

F A

C

IL

IT

Y

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

F

IR

E M

E N

'S R

O A

D

F R

A C

K V

IL

L

E

P A

G E

N E

R A

L N

O T

E S

JEB

MSR

MSR

S.1

01/08/25

1 2 3 5 6 7 8 9

B

C

D

E

F

C'

S.11

Aa

5'

2.1 3.1 5.1

H

G

S.10

(-4' - 0")F5

(-2' - 2")F5 (-2' - 2")F5

(-2' - 2")F5

(-4' - 0")F5

(-2' - 2")F5

(-4' - 0")F5(-4' - 0")F5

(-2' - 2")F6 (-2' - 2")F6

(-2' - 2")F5(-2' - 2")F5(-2' - 2")F5(-2' - 2")F5(-2' - 2")F5

(-4' - 0")F5

(-4' - 2")F6

(-4' - 2")F6

(-4' - 0")F5

(-4' - 0")F5 (-4' - 2")F6

(-4' - 0")F5

(-4' - 2")F6

S.10

(-4' - 0")F7 (-4' - 0")F7

(-4' - 0")F7 (-4' - 0")F7 (-4' - 0")F7

(-4' - 0")F7(-4' - 0")F7

(-4' - 0")F7

S.9

S.10

S.9

S.11

5" THICK REINF. CONCRETE

FLOOR SLAB REINF. W/ 6x6 W2.9xW2.9 WWF W/ VAPOR

BARRIER ON 2B STONE BASE

COMPACTED TO 8" DEPTH

REFER TO MEP DRAWINGS FOR

RADIANT HEATING SYSTEM

DETAILS

S.11

(-4' - 0")F5

/2

/2

/2

/2

/2

/2

/2

/2

23' - 0" 23' - 0" 23' - 0" 19' - 0"

12' - 0"

11' - 4" 8" 23' - 4"12' - 8"

20' - 0" 3' - 0" 17' - 0" 6' - 0" 18' - 0" 5' - 0"

4 1/2" 20' - 0" 20' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 40' - 0" 9"

177' - 1 1/2"

P24 [-0' - 8"]

(-4' - 0")F5 P24 [-1' - 4"]

(-4' - 0")F5 P24 [-1' - 4"]

P24 [-1' - 4"]

P24 [-1' - 4"]

P24 [-1' - 4"]

(-4' - 0")F5 P24 [-0' - 8"]

(-4' - 0")F5 P24 [-0' - 8"]

(-4' - 0")F5 P24 [-0' - 8"]

(-4' - 0")F5 P24 [-0' - 8"] P24 [-1' - 4"]

P24 [-1' - 4"]

P24 [-1' - 4"]

P24 [-1' - 4"]

P24 [-1' - 4"]

(-4' - 0")F5 P24 [-0' - 8"]

(-4' - 0")F5 P24 [-0' - 8"](-4' - 0")F5

P24 [-0' - 8"] (-4' - 0")F5

P24 [-0' - 8"]

(-4' - 0")F5 P24 [-0' - 8"]P24 [-0' - 8"]

(-4' - 0")F5 P24 [-0' - 8"]

(-4' - 0")F5 P24 [-0' - 8"]

P24 [-0' - 8"]

P18 [4' - 0"]P18 [4' - 0"]

P24 [4' - 0"] P24 [4' - 0"] P24 [4' - 0"] P24 [4' - 0"]

P24 [4' - 0"]P24 [4' - 0"]P24 [4' - 0"]P24 [4' - 0"]

8" REINF. CONCRETE

SLAB ON GRADE W/

VAPOR BARRIER ON

2B STONE BASE

COMPACTED TO 8"

DEPTH

(SEE S.5 FOR REINF.)

S L O

P E

S

E

A R

C H

S L O

P

S

E

A R

C H

CJ

CJ

CJ

C J

C J

C J

C J

15 KIPS 18 KIPS 20 KIPS 28 KIPS 36 KIPS 29 KIPS 45 KIPS 28 KIPS

51 KIPS 48 KIPS

55 KIPS

86 KIPS

75 KIPS

51 KIPS

28 KIPS37 KIPS

14 KIPS

26 KIPS

41 KIPS40 KIPS

25 KIPS

14 KIPS

14 KIPS

37 KIPS27 KIPS21 KIPS

5 KIPS

30 KIPS 33 KIPS

16 KIPS

20 KIPS

8 KIPS 10 KIPS

11 KIPS

10 KIPS 10 KIPS

10 KIPS 20 KIPS 20 KIPS 10 KIPS

10 KIPS20 KIPS20 KIPS10 KIPS

HSS6x6x3/8

CANOPY COLUMN

(TYP)

RAMMED AGGREGATE PIER

(TYP) SIZE, LOCATION AND

DESIGN BY OTHERS

/2

/2

45 KIPS

CONCRETE PAD - SEE

SITE PLANS (TYP)

FOUNDATION PLAN NOTES:

1. FOUNDATION ELEVATIONS ARE BASED ON A STRUCTURAL CONCRETE FINISHED FLOOR SLAB ELEVATION OF 0'-0" (EQUAL TO

ARCHITECTURAL ELEVATION OF 0'-0")

2. CONCRETE FLOOR SLABS SHALL BE PLACED ON A 15 MIL VAPOR BARRIER AND 2B STONE (AASHTO #57 CRUSHED STONE AGGREGATE) BASE COMPACTED TO DEPTH AS SPECIFIED ON PLANS. THICKNESS OF FLOOR SLABS VARY, SEE PLANS, SECTIONS, AND DETAILS.

3. ISOLATED COLUMN AND WALL FOOTING SIZE ARE INDICATED AS: F# (SEE SCHEDULE FOR REINFORCING)

4. ELEVATIONS INDICATED AT FOOTING LOCATIONS ARE TO BOTTOM OF SPREAD FOOTING.

5. COLUMN PIER SIZE ARE INDICATED AS: P#. TOP OF PIERS TO BE SET 8" BELOW FLOOR SLAB ELEVATION (U.N.O.).

6. ALL FOOTINGS EXPOSED TO FREEZE-THAW CONDITIONS SHALL BE SET A MINIMUM OF 4'-0" DEEP MEASURED FROM FINISHED GRADE TO

THE BOTTOM OF THE FOOTING. SEE CIVIL PLANS FOR FINISHED GRADE ELEVATIONS.

7. "CJ" DESIGNATES SAW CUT CONTROL JOINT. FOR CONTROL JOINT SPACING IN OFFICE AREA, SEE TYPICAL DETAIL ON S.5.

8. "XX KIPS" INDICATES TOTAL UNFACTORED COLUMN REACTION AT EACH FOOTING FOR RAMMED AGGREGATE PIER DESIGN (BY OTHERS).

9. REFER TO ARCHITECTURAL, MECHANICAL, EQUIPMENT, AND CIVIL SITE PLANS FOR ADDITIONAL INFORMATION NOT INDICATED ON THESE

PLANS. CONTRACTOR TO COORDINATE LOCATION OF UTILITIES WITH PLAN INFORMATION.

10. SEE TYPICAL DETAILS, SECTIONS, AND NOTES FOR ADDITIONAL INFORMATION NOT REPEATED HERE.

11. CONTRACTOR TO COORDINATE AND VERIFY THE FOUNDATION WALL SECTIONS TO INCORPORATE WITH ARCHITECTURAL DETAIL.

C e tr o n ia R o a d S u it e n to w n

P

A

.4

.7

EMA-FIRE SCHOOL

DATE

T H

E C

O U

N T

Y O

F S

C H

U Y

L K

IL

L

M

N D

S T

R E

E T

P

O T

T S

V

IL

L E

P

A

DATE

Drawn By:

Y

K

IM

A R

C H

IT

E

C T

S

W

M a rk e t S tr e e t

P o tt s v ill e P

A

T

.6

.4 y k a a ia g m a il.

c o m

T H

E S

C H

U Y

L K

IL

L

C O

U N

T Y

E M

E R

G E

N C

Y S

E R

V

IC

E S

T R

A

IN

IN

G

F A

C

IL

IT

Y

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

F

IR

E M

E N

'S R

O A

D

F R

A C

K V

IL

L

E

P A

F O

U N

D A

T

IO

N P

L A

N

JEB

MSR

MSR

S.2

01/08/25

1/8" = 1'-0"

FOUNDATION PLAN

B

C

D

E

F

C'

S.11

Aa

5'

3 EQ. SPA. =

12' - 0"

5 EQ. SPA. =

12' - 0"

4 EQ. SPA. =

12' - 0"

2.1 3.1 5.1

H

G

S.10

S.10

S.9

S.10

S.9

S.11

S.11

6' - 0" 6' - 0"

M C -1

M C -2

M C -2

M C -3

M C -4

M C -3

M C -1

M C -2

M C -2

M C -5

M C -6

M C -5

M C -2

M C -2

M C -3

M C -3

M C -3

M C -3

M C -2

M C -2

OPERABLE

PARITION BELOW.

SEE ARCH DWGS

SEE RTU CURB

SUPPORT DETAIL ON S.7

(TYP @ EACH RTU)

11' - 4" 8"

12' - 0"

(2 )1

K

(2 )1

K

(2 )1

K

(2 )1

K

W X

-2

/2

W X

-2

/2

W X

W X

W X

W X

W X

-2

/2

W X

-2

/2

W X

-2

/2

W X

-2

/2

W X

-2

/2

W16X31

( -2 1/2" )

W18X35

( -2 1/2" )

W16X31

( -2 1/2" )

W16X31

( -2 1/2" )

W24X55

( -2 1/2" )

W16X31

( -2 1/2" )

W18X35

( -2 1/2" )

W X

-2

/2

W18X40

( -2 1/2" )

W18X35

( -2 1/2" )

W16X31

( -2 1/2" )

W16X31

( -2 1/2" )

W24X55

( -2 1/2" )

W16X31

( -2 1/2" )

W X

W X

W X

W X

-2

/2

W X

-2

/2

W X

-2

/2

W X

-2

/2

W X

-2

/2

W X

-2

/2

W18X35

( -2 1/2" )

W24X55

( -2 1/2" )

W18X35

( -2 1/2" )

W18X35

( -2 1/2" )

W18X35

( -2 1/2" )

W16X31

( -2 1/2" )

W16X31

( -2 1/2" )

W24X55

( -2 1/2" )

W16X31

( -2 1/2" )

W18X40

( -2 1/2" )

W16X31

( -2 1/2" )

W X

-2

/2

W X

-2

/2

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

W X

-3

W X

-3

W16X31

( -3' - 0" )

K

W X

-3

/8

W12X26

( -3' - 5 3/8" )

W12X26

( -3' - 5 3/8" )

W12X26

( -3' - 5 3/8" )

W12X26

( -3' - 5 3/8" )

W12X26

( -3' - 5 3/8" )

W12X26

( -3' - 5 3/8" )

W X

-3

/8

W X

-3

/8

W X

-3

/8

W X

-3

/8

W X

-3

/8

W X

-3

/8

W X

-3

/8

W X

-3

/8

W X

-3

/8

W X

-3

/8

W X

-3

/8

W X

-3

/8

W X

-3

/8

W X

-3

/8

W X

-3

/8

K

W16X31

( -3' - 0" )

W12X26

( -3' - 5 3/8" )

K

W16X31

( -3' - 0" )

W16X31

( -3' - 0" )

W X

-3

W X

-3

W X

-3

W X

-3

W12x19 (-3'-0")

/2

C A

N T

/8

H

S S

H

S S

H

S S

H

S S

H

S S

H

S S

H

S S

H

S S

H

S S

H

S S

H

S S

H

S S

H

S S

H

S S

H

S S

H

S S

K

(2 )2

K

(2 )2

K

(2 )2

K

K

(2 )1

K

(2 )1

K

(2

)2 K

ROOF FRAMING NOTES:

1. ALL ELEVATIONS SHOWN ARE TO TOP OF ROOF FRAMING MEMBERS BASED ON A FINISHED FLOOR ELEVATION OF 0'-0".

2. ELEVATION FOR TOP OF ROOF FRAMING MEMBERS IS 14'-1 1/2". VARIATIONS IN ELEVATION ARE INDICATED AS (±##").

3. HORIZONTAL SPACING (CENTER TO CENTER) OF ROOF MEMBERS TO BE:

BEAMS: AS NOTED ON PLANS

JOISTS: 6'-0" MAX.

TRUSS: 5'-0" MAX.

BRIDGING: 1/3 POINTS OF SPAN

4. COORDINATE ROOF OPENINGS AND UTILITY PENETRATION SIZE, LOCATION, AND SUPPORT FRAMING WITH MANUFACTURES CLEARANCE REQUIREMENTS. FOR OPENINGS

LARGER THAN 12" REFER TO TYPICAL DETAILS FOR ADDITIONAL FRAMING REQUIREMENTS.

5. ROOF DECKING TO BE 1 1/2" TYPE B x 18 GA. GALVANIZED METAL DECKING. REFER TO DETAILS AND WALL SECTIONS FOR ADDITIONAL INFORMATION.

6. "MC-#" INDICATES MOMENT CONNECTION TYPE - REFER TO DETAILS FOR DESIGN.

7. REFER TO ARCHITECTURAL AND MECHANICAL PLANS FOR ADDITIONAL INFORMATION NOT INDICATED ON THESE PLANS.

8. SEE TYPICAL DETAILS, SECTIONS, AND NOTES FOR ADDITIONAL INFORMATION NOT REPEATED HERE.

9. CONTRACTOR TO COORDINATE FINAL RTU CURB DIMENSIONS WITH EQUIPMENT VENDOR FINAL SUBMISSION.

10. JOIST MANUFACTURER TO DESIGN FOR DEFLECTION AND CAMBER TOP CHORD AS REQUIRED.

11. DESIGNATES MOMENT CONNECTION

12. "+HSS" INDICATES ADDITIONAL DECK SUPPORT STEEL. SEE SECTION 2/S.10 FOR ADDITIONAL INFORMATION.

C e tr o n ia R o a d S u it e n to w n

P

A

.4

.7

EMA-FIRE SCHOOL

DATE

T H

E C

O U

N T

Y O

F S

C H

U Y

L K

IL

L

M

N D

S T

R E

E T

P

O T

T S

V

IL

L E

P

A

DATE

Drawn By:

Y

K

IM

A R

C H

IT

E

C T

S

W

M a rk e t S tr e e t

P o tt s v ill e P

A

T

.6

.4 y k a a ia g m a il.

c o m

T H

E S

C H

U Y

L K

IL

L

C O

U N

T Y

E M

E R

G E

N C

Y S

E R

V

IC

E S

T R

A

IN

IN

G

F A

C

IL

IT

Y

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

F

IR

E M

E N

'S R

O A

D

F R

A C

K V

IL

L

E

P A

L O

W R

O O

F F

R A

M

IN

G P

L A

N

JEB

MSR

MSR

S.3

01/08/25

1/8" = 1'-0"

LOW ROOF FRAMING PLAN

B

C

D

E

F

C'

S.11

Aa

5'

2.1 3.1 5.1

H

G

S.10

S.9

S.9

S.11

S.11

(T Y

P

E Q

M C -7

M C -7

M C -8

M C -8

M C -8

M C -7

M C -8

M C -8

M C -7

M C -8

W X

-2

/2

W X

-2

/2

W X

-2

/2

W X

-2

/2

W X

-2

/2

W X

-2

/2

W18X35

W X

-2

/2

W X

-2

/2

W18X35

W21X44

W21X44

W21X44

30K8

30K8

30K8

30K8

30K8

30K8

30K8

30K8

30K8

30K8

30K8

30K8

30K8

30K8

ROOF FRAMING NOTES:

1. ALL ELEVATIONS SHOWN ARE TO TOP OF ROOF FRAMING MEMBERS BASED ON A FINISHED FLOOR ELEVATION OF 0'-0".

2. ELEVATION FOR TOP OF ROOF FRAMING MEMBERS IS 18'-5 1/2". VARIATIONS IN ELEVATION ARE INDICATED AS (±##").

3. HORIZONTAL SPACING (CENTER TO CENTER) OF ROOF MEMBERS TO BE:

BEAMS: AS NOTED ON PLANS

JOISTS: 6'-0" MAX.

TRUSS: 5'-0" MAX.

BRIDGING: 1/3 POINTS OF SPAN

4. COORDINATE ROOF OPENINGS AND UTILITY PENETRATION SIZE, LOCATION, AND SUPPORT FRAMING WITH MANUFACTURES CLEARANCE REQUIREMENTS. FOR OPENINGS

LARGER THAN 12" REFER TO TYPICAL DETAILS FOR ADDITIONAL FRAMING REQUIREMENTS.

5. ROOF DECKING TO BE 1 1/2" TYPE B x 18 GA. GALVANIZED METAL DECKING. REFER TO DETAILS AND WALL SECTIONS FOR ADDITION INFORMATION.

6. "MC-#" INDICATES MOENT CONNECTION TYPE - REFER TO DETAILS FOR DESIGN.

7. REFER TO ARCHITECTURAL AND MECHANICAL PLANS FOR ADDITIONAL INFORMATION NOT INDICATED ON THESE PLANS.

8. SEE TYPICAL DETAILS, SECTIONS, AND NOTES FOR ADDITIONAL INFORMATION NOT REPEATED HERE.

9. CONTRACTOR TO COORDINATE FINAL RTU CURB DIMENSIONS WITH EQUIPMENT VENDOR FINAL SUBMISSION.

10. JOIST MANUFACTURER TO DESIGN FOR DEFLECTION AND CAMBER TOP CHORD AS REQUIRED.

11. DESIGNATES MOMENT CONNECTION

C e tr o n ia R o a d S u it e n to w n

P

A

.4

.7

EMA-FIRE SCHOOL

DATE

T H

E C

O U

N T

Y O

F S

C H

U Y

L K

IL

L

M

N D

S T

R E

E T

P

O T

T S

V

IL

L E

P

A

DATE

Drawn By:

Y

K

IM

A R

C H

IT

E

C T

S

W

M a rk e t S tr e e t

P o tt s v ill e P

A

T

.6

.4 y k a a ia g m a il.

c o m

T H

E S

C H

U Y

L K

IL

L

C O

U N

T Y

E M

E R

G E

N C

Y S

E R

V

IC

E S

T R

A

IN

IN

G

F A

C

IL

IT

Y

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

F

IR

E M

E N

'S R

O A

D

F R

A C

K V

IL

L

E

P A

H

IG

H R

O O

F F

R A

M

IN

G P

L A

N

JEB

MSR

MSR

S.4

01/08/25

1/8" = 1'-0"

HIGH ROOF FRAMING PLAN

TYP. FROST WALL

THICKENED SLAB DETAIL

CRACK CONTROL JOINTS SAW CUT JOINTS

TYPICAL ISOLATION JOINT DETAILS

(M

IN

8"

T

T /3

"CSJ" = FORMED CONSTRUCTION JOINT

T

T /3

SPACE AT 15'-0" MAX EACH WAY IN OFFICE AREA

SAW CUT - 1/4" DEPTH

(SAW WITHIN 24 HRS.

OF PLACING

CONCRETE)

DIAMOND

PATTERN

CIRCLE

PATTERN

WALL

TRIANGLE

PATTERN

#4 REBAR @ 12" O.C.

#4 BENT REBAR

@ 12" O.C.

1/4"

PREMOLDED

JOINT FILLER

STOP

REINFORCING

6" FROM JOINT

STOP REINFORCING

6" FROM JOINT

DEPRESSED SLAB DETAIL

T

V A

R

IE

S

S E

E P

L A

N

2T

T

#4 NOSING BAR

3" 3"

SEE GARAGE SLAB

REINFORCEMENT

DETAIL THIS SHEET

1/3 DEPTH (SAW WITHIN

24 HRS. OF PLACING

CONCRETE)

REINFORCEMENT BAR

TRIANGLE

PATTERN

SCALE: 3/4"=1'-0"

SCALE: 3/4"=1'-0"

SCALE: 3/4"=1'-0"

WELDED WIRE FABRIC

CONCRETE WALL CORNER REINFORCING CONCRETE WALL CORNER REINFORCING

NOTES:

1. DO NOT EXTEND HORIZONTAL

REINFORCING BARS THROUGH

CONTROL JOINTS. TERMINATE REBAR

3" BEFORE CONTROL JOINT.

2. TYPE OF CONTROL JOINT USED MAY

VARY FROM TYPE SHOWN.

CONTRACTORS OPTION TO USE

ALTERNATIVE JOINT TYPE.

SCALE: 3/4"=1'-0"

T Y

P

NOTES:

1. DO NOT EXTEND HORIZONTAL REINFORCING BARS

THROUGH CONTROL JOINTS. TERMINATE REBAR 3"

BEFORE CONTROL JOINT.

2. TYPE OF CONTROL JOINT USED MAY VARY FROM TYPE

SHOWN. CONTRACTORS OPTION TO USE

ALTERNATIVE JOINT TYPE.

T Y

P

ALIGN WALL AND

FLOOR

CONTROL

JOINTS

10'-0" MIN.

SEE PLANS

SCALE: 3/4"=1'-0"

3"

3"

MIN

44 BAR DIA

MIN

44 BAR DIA

MIN

44 BAR DIA

M

IN

B

A R

D

IA M

IN

B

A R

D

IA

U.N.O.

1' - 6"

INTERIOR NON-LOAD

BEARING METAL STUD WALL

WELDED WIRE

FABRIC (SEE PLAN)

X X X X X X X X

(2) #5 CONT REBAR

GARAGE SLAB REINFORCEMENT

#5 REBAR @ 12" O.C. EW

COORDINATE SLAB FINISH W/

ARCHITECTURAL DRAWINGS

"CJ" = SAWED CONTROL JOINT -

SEE PLANS FOR GARAGE SLAB LOCATIONS

TYPICAL CONCRETE SLAB AND WALL

OPENING REBAR REINFORCING LAYOUT

WALL/FOOTING PIPE SLEEVE DETAIL

SCALE: 3/4"=1'-0"

*UTILITY PIPE/CONDUIT SEPARATION PER CIVIL

DESIGN DETAILS

SCALE: 3/4"=1'-0"

M

IN

C L R

MIN.

1' - 0"

C L R

1' - 11" *

2" CLR.

PIPE SLEEVE

(2"+PIPE DIA.)

REINF. REBAR (SEE WALL SECTIONS)

ADDITIONAL REBAR @ EACH FACE

(SIZE TO MATCH ADJACENT HORIZ.

REINF.)

F O

O T

IN

G

F O

U N

D A

T

IO

N W

A L

L

1'

6"

8"

OPENING O

P

E N

IN

G

2" CLR.

C L R

C e tr o n ia R o a d S u it e n to w n

P

A

.4

.7

EMA-FIRE SCHOOL

DATE

T H

E C

O U

N T

Y O

F S

C H

U Y

L K

IL

L

M

N D

S T

R E

E T

P

O T

T S

V

IL

L E

P

A

DATE

Drawn By:

Y

K

IM

A R

C H

IT

E

C T

S

W

M a rk e t S tr e e t

P o tt s v ill e P

A

T

.6

.4 y k a a ia g m a il.

c o m

T H

E S

C H

U Y

L K

IL

L

C O

U N

T Y

E M

E R

G E

N C

Y S

E R

V

IC

E S

T R

A

IN

IN

G

F A

C

IL

IT

Y

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

F

IR

E M

E N

'S R

O A

D

F R

A C

K V

IL

L

E

P A

T Y

P

IC

A L

C O

N C

R E

T E

D E

T A

IL

S

JEB

MSR

MSR

S.5

01/09/25

COLUMN FOOTING SCHEDULE

MARK DIMENSIONS LONG REINF.

F4

F5

F6

F7

5'-6" x 5'-6" x 1'-6"

5'-0" x 5'-0" x 1'-6"

6'-0" x 6'-0" x 1'-6"

7'-0" x 7'-0" x 1'-6"

(5) #5

(6) #5

(7) #5

(8) #5

(5) #5

(6) #5

(7) #5

(8) #5

SHORT REINF. REMARKS

TOP & BOT

TOP & BOT

TOP & BOT

TOP & BOT

COLUMN PIER SCHEDULE

MARK DIMENSIONS REINFORCING

P16

P24

1'-4" x 1'-4"

2'-0" x 2'-0"

(8) #6

(8) #8

REINF. TIES

(2) #3 @ 12"

(2) #3 @ 12"

BASE PLATE

FIRST FLOOR = 0'-0"

HIGH ROOF = 18'-5 1/2"

COLUMN

NO.

LEVEL

/4

BP-1

H S

S x x /2

BP-1 BP-1

/4

BP-5

/4

BP-1

/4

H S

S x x /2

Aa-4, Aa-5'

G-1, G-2.1, G-3.1, G-5.1, H-1, H-2.1, H-3.1, H-5.1

C'-5, C'-6, C'-7, C-2, C-3, D-2, E-2, E-3, E-5, E-6, E-7

A-1, F-1 A-8, B-9, C'-9, E-9, F-8

H S

S x x /2

H S

S x x /8

H S

S x x /2

ENTRANCE CANOPY = 11'-1 1/2"

LOW ROOF = 14'-1 1/2"

CANOPY STEEL = 10'-8 1/8"

/8

/2

A-2, A-3, A-5, A-6, A-7, C-1, E-1, F-2, F-3, F-5, F-6, F-7

B-8, C'-8, E-8

BP-3

/4

BP-2

/4

H S

S x x /2

H S

S x x /2

/2

/2

H S

S x x /2

BP-4

/4

A-9, F-9

BASE PLATE "BP-1 "

SCALE: 3/4"=1'-0"

1' - 6"

1' - 4" 1' - 2"

5/16"

4" 1' - 2"

7" 7"

T Y

P

/2

3/4" THK

BASE PLATE

(4) 3/4" DIA. ASTM

F1554 GR 36 HEADED

ANCHOR BOLTS (12"

MIN. EMBEDMENT)

BASE PLATE "BP-2 "

SCALE: 3/4"=1'-0"

BASE PLATE "BP-3 "

SCALE: 3/4"=1'-0"

T Y

P

3" 6" 2" TYP

1 1/4" THK

BASE PLATE

5/16"

(6) 1" DIA. ASTM

F1554 GR 36 HEADED

ANCHOR BOLTS (12"

MIN. EMBEDMENT)

8" 8"

T Y

P

TYP

3"

1 1/4" THK

BASE PLATE

5/16"

(6) 1" DIA. ASTM

F1554 GR 36 HEADED

ANCHOR BOLTS (12"

MIN. EMBEDMENT)

1' - 6"

1' - 4"

BASE PLATE "BP-4 "

SCALE: 3/4"=1'-0"

BASE PLATE "BP-5 "

SCALE: 3/4"=1'-0"

T Y

P

1 1/2" THK

BASE PLATE

5/16"

(6) 1" DIA. ASTM

F1554 GR 36 HEADED

ANCHOR BOLTS (12"

MIN. EMBEDMENT)

8" 8"

TYP

2"

1 1/4" THK

BASE PLATE

5/16"

(6) 1" DIA. ASTM

F1554 GR 36 HEADED

ANCHOR BOLTS (12"

MIN. EMBEDMENT)

5" 1' - 1"

7" 7"

2"2"

/4

COVER

2" CLR.

GRADE - SEE

CIVIL/SITE

DRAWINGS

COLUMN - SEE SCHEDULE

SLAB - SEE PLAN FOR

THICKNESS AND REINF.

COLUMN FOOTING - SEE

PLAN AND SCHEDULE

SEE SCHED.

S E

E S

C H

E D

COLUMN PIER - SEE PLAN

AND SCHEDULE

BASE PLATE W/ ANCHOR

BOLTS - SEE BASE PLATE

DETAILS FOR SIZE AND TYPE1/4" THK LEVELING PLATE

1" THK. NON-SHRINK

HIGH STRENGTH GROUT

/4

COVER

2" CLR.

COLUMN - SEE SCHEDULE

COLUMN FOOTING - SEE

PLAN AND SCHEDULE

SEE SCHED.

S E

E S

C H

E D

BASE PLATE W/ ANCHOR

BOLTS - SEE BASE PLATE

DETAILS FOR SIZE AND TYPE1/4" THK LEVELING PLATE

1" THK. NON-SHRINK

HIGH STRENGTH GROUT

ISOLATION JOINT AT COLUMN -

SEE TYPICAL DETAILS

ISOLATION JOINT AT COLUMN -

SEE TYPICAL DETAILS

2x4 KEY

COLUMN FOOTING AT EXTERIOR

COLUMN FOOTING AT INTERIOR

9" (GARAGE)

4 1/2" (OFFICE)

S E

E P

L A

N

RAMMED AGGREGATE

PIER (DESIGN BY OTHERS)

RAMMED AGGREGATE

PIER (DESIGN BY OTHERS)

PIER TIE LAYOUT DETAILS

SINGLE TIE

(4) VERT

BARS

NOTES:

1. REFER TO PIER SCHEDULE FOR SIZE OF VERTICAL REBAR

2. TIE BARS SIZES TO BE #3 REBAR

3. PROVIDE (3) TIE BARS AT 6" O.C. TOP & BOTTOM. REMAINING BARS TO

BE SPACED @ 12" O.C.

4. REFER TO FOUNDATIO PLAN(S) FOR PIER SIZES (P#) AND LOCATIONS

DOUBLE TIE

(6) VERT

BARS

DOUBLE TIE

(8) VERT

BARS

3 TIE SET

(12) VERT

BARS

VERTICAL REBAR

PER PIER

SCHEDULE

3 TIE SET (12)

VERT BARS

REBAR PER FOOTING SCHEDULE

SINGLE TIE-(#) VERTICAL

BARS PER SCHEDULE

P E

R S

C H

E D

U L E

TYPICAL BOND BEAM

DETAIL AT CORNER

CONTROL JOINTS

TYPICAL INTERSECTION

OF MASONRY WALLS TYPICAL EXPANSION JOINT AT COLUMN

SCALE: 3/4"=1'-0"

SCALE: 3/4"=1'-0"

SCALE: 3/4"=1'-0" SCALE: 3/4"=1'-0"

(3)#5 VERT. REBAR

(GROUT CORES

SOLID)

(2)#5 BENT REBAR

x 5'-0" LONG

(2'-6" EA. LEG)

(2)#5 REBAR BOND BEAM

REINFORCING U.NO.

CAULK & JOINT

FILLER (B.S.)

SYTHETIC RUBBER

CONTROL JOINT

BUILDING PAPER(1) #5 (TYP)

GROUT CORES

SOLID @ REINF

3000 PSI CONC GROUT

CONT. HORIZ. TRUSS

TYPE JOINT REINF.

AT 16" o.c.

(1) #5 VERTICAL BAR -

GROUT CORES SOLID

w/ 3000 psi CONC.

GROUT

STEEL

COLUMN

WIRE MASONRY

ANCHOR AT

16" o.c. VERT

2" WIDE Z

STRAPS @

16" o.c.

L A

P D

IS

T

A N

C E

M

IN

C e tr o n ia R o a d S u it e n to w n

P

A

.4

.7

EMA-FIRE SCHOOL

DATE

T H

E C

O U

N T

Y O

F S

C H

U Y

L K

IL

L

M

N D

S T

R E

E T

P

O T

T S

V

IL

L E

P

A

DATE

Drawn By:

Y

K

IM

A R

C H

IT

E

C T

S

W

M a rk e t S tr e e t

P o tt s v ill e P

A

T

.6

.4 y k a a ia g m a il.

c o m

T H

E S

C H

U Y

L K

IL

L

C O

U N

T Y

E M

E R

G E

N C

Y S

E R

V

IC

E S

T R

A

IN

IN

G

F A

C

IL

IT

Y

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

F

IR

E M

E N

'S R

O A

D

F R

A C

K V

IL

L

E

P A

C O

N C

R E

T E

A N

D M

A S

O N

R Y

D E

T A

IL

S

JEB

MSR

MSR

S.6

01/09/25

3/16" = 1'-0"

COLUMN SCHEDULE

TYPICAL JOIST

REINFORCING DETAIL

NOTE: A WEB STIFFENER MUST BE APPLIED TO ANY JOIST WHEN

A CONCENTRATED LOAD IS PLACED ON THE JOIST 4" OR MORE

AWAY FROM A PANEL POINT.

SCALE: 3/4"=1'-0"

P A

N E

L P

O

IN

T

P A

N E

L P

O

IN

T

CONCENTRATED

LOAD DUE TO

MECH

EQUIP, ETC.

(2) ANGLE 1 1/2x1 1/2x1/8 B.S. (TYP)+/- 2'-0"

+/- 2'-0"

NOTES:

1. ALL DIMENSIONS RELATIVE TO RTU SHALL BE COORDINATED

W/MEP DRAWINGS

2. LOCATE HSS @ JOIST PANEL POINTS WHERE APPLICABLE.

3. PROVIDE TWO (2) FRAMES FOR DUCT PENETRATIONS PER RTU

TYPICAL RTU CURB SUPPORT DETAIL

SCALE: 3/4"=1'-0"

SECTION

PLAN

ROOF FRAMING

PROVIDE TUBE STEEL CURB

AS SHOWN BELOW

CONTINUOUS AROUND

ENTIRE PERIMETER OF UNIT

EXTEND TUBE STEEL TO NEXT

ROOF FRAMING MEMBER

WHEN RTU EXTENDS PAST

ROOF TOP

UNIT (RTU)

DUCT

PENETRATION

FIELD WELD ANGLE's TO ROOF

FRAMING (TYP. BOTH SIDES)

METAL ROOF DECK

ROOF FRAMING

HSS 6x3x5/16 (LSH) w/ (2) L2x2x5/16 (SHOP WELD TO

TUBE)

TYPICAL FRAMING FOR DUCT OPENINGS

ANGLE 7x4x3/8" (LLH)

(THIS DETAIL APPLIES FOR OPENINGS 1'-0" & LARGER)

NOT TO SCALE

* DIMENSION VARIES - SEE MECH. &

ARCH. DWGS.

CLIP ANGLES

4x4x5/16x0'-6" LONG

ANGLE 3 1/2x3 1/2x5/16

(1'-0" to 5'-0")

ANGLE 5x3 1/2x5/16 (LLV)

(5'-0" to 6'-0")

ANGLE 6x3 1/2x5/16 (LLV)

(6'-0" to 8'-0")

NOTE:

1. NO OPENINGS SHALL BE CUT IN FLOOR OR ROOF DECK UNLESS

THEY CAN BE IMMEDIATELY PROTECTED BY THE G.C. IN

ACCORDANCE w/ OSHA REQUIREMENTS.

2. CONTRACTOR IS RESPONSIBLE FOR PROVIDING & INSTALLING ALL

STRUCTURAL STEEL, MISC STEEL, AND LOOSE LINTELS THAT ARE

NECESSARY TO SUPPORT ALL ROOF TOP MOUNTED EQUIPMENT.

3. CONTRACTOR TO COORDINATE SIZE, LOCATION, AND DUCT

FRAMING CLEARANCES WITH MEP AND ARCH. DRAWINGS.

4. NO STRUCTURAL FRAMING MEMBERS ARE TO BE CUT, MODIFIED, OR

MOVED TO PLACE DUCT OPENINGS.

SEE MEP DWGS

S E

E M

E P

D W

G S

CENTER (TYP)

1/4" MAX. FROM

BEARING

2 1/2" MIN.

ROOF JOIST

(SEE PLAN)

ROOF JOIST

(SEE PLAN) ROOF BEAM

(SEE PLAN)

2 1/2" JOIST SEAT

METAL DECK

3/16" 2"

3/16" 2"

TYP.

TYPICAL INTERIOR GIRDER TO

JOIST CONNECTION

SCALE: 3/4"=1'-0"

HSS COLUMN

SHEAR TAB

CONNECTION (SEE

TYPICAL DETAILS)

ROOF DECK

CONNECTION PLATE TOP &

BOTTOM (SEE DETAILS FOR

GEOMETRY AND

ADDITIONAL INFORMATION)

ROOF BEAM ROOF BEAM

BEAM TO COLUMN MOMENT

CONNECTION DETAIL

SCALE: 3/4"=1'-0"

(T Y

P

/2

(T Y

P

S P

A

3"3/8" THK SHEAR TAB W/

SLOTTED HOLES FOR

3/4" DIA. A325N BOLTS

COPE BEAM FLANGE AS

REQUIRED AT GIRDER

CONNECTIONS

WIDE FLANGE GIRDER

OR HSS COLUMN

FLOOR BEAM W/ STD

HOLES IN WEB

1/4"

1/4"

TYPICAL BEAM TO GIRDER OR

COLUMN CONNECTION DETAIL

SCALE: 3/4"=1'-0"

BEAM SIZE

W8, W10, W12

W16

W18

W21, W24

# OF BOLTS

7"

3 1/2"

/2

5/8" THK PLATE

HSS COLUMN

ROOF MOMENT CONNECTION DETAILS

MC-3

7"

3 1/2"

/2

5/8" THK PLATE

HSS COLUMN

5/16"

5/16"

2 SIDES

MC-2

3 1/2"

/2

CJP

CJP

5/8" THK PLATE

HSS COLUMN

5/16"

5/16"

MC-4

SCALE: 1"=1'-0"

(DIMENSIONS SHOWN ARE TYPICAL U.N.O.)

5/16"

5/16"

3 SIDES

3 1/2"

/2

5/8" THK PLATE

HSS COLUMN

5/16"

5/16"

3 SIDES

MC-1

7"

3 1/2"

/2

CJP

CJP

5/8" THK PLATE

HSS COLUMN

5/16"

5/16"

MC-6

4" 3" 3" 1 1/2"

/2

5/8" THK PLATE

HSS COLUMN

MC-5

4" 3" 3" 1 1/2"

5/16"

5/16"

3 SIDES

NOTE: DETAILS SHOWN ARE FOR BOTTOM PLATE MOMENT

CONNECTIONS. MOMENT CONNECTION TOP PLATES ARE ONE PIECE

WITH NO CUT-OUT FOR HSS COLUMN. COLUMNS TERMINATE AT

UNDERSIDE OF TOP PLATE MOMENT CONNECTION.

TOP PLATE (SEE NOTE)

TOP PLATE (SEE NOTE)

TOP PLATE (SEE NOTE)

TOP PLATE (SEE NOTE)

(CJP WELDS FOR BOTTOM PLATE

ONLY, SEE NOTE FOR TOP PLATE)

(CJP WELDS FOR BOTTOM PLATE

ONLY, SEE NOTE FOR TOP PLATE)

3 1/2"

/2

5/8" THK TOP &

BOT PLATE

HSS COLUMN

5/16"

5/16"

TYP

MC-7

5 3/4"

TOP PLATE

5/8" THK BOT

PLATE

3 1/2"

/2

5/8" THK TOP &

BOT PLATE

HSS COLUMN

5/16"

5/16"

TYP

MC-8

5 3/4"

TOP PLATE

5/8" THK BOT

PLATE

5/8" THK TOP &

BOT PLATE

C e tr o n ia R o a d S u it e n to w n

P

A

.4

.7

EMA-FIRE SCHOOL

DATE

T H

E C

O U

N T

Y O

F S

C H

U Y

L K

IL

L

M

N D

S T

R E

E T

P

O T

T S

V

IL

L E

P

A

DATE

Drawn By:

Y

K

IM

A R

C H

IT

E

C T

S

W

M a rk e t S tr e e t

P o tt s v ill e P

A

T

.6

.4 y k a a ia g m a il.

c o m

T H

E S

C H

U Y

L K

IL

L

C O

U N

T Y

E M

E R

G E

N C

Y S

E R

V

IC

E S

T R

A

IN

IN

G

F A

C

IL

IT

Y

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

F

IR

E M

E N

'S R

O A

D

F R

A C

K V

IL

L

E

P A

S T

R U

C T

U R

A L

S T

E E

L D

E T

A

IL

S

JEB

MSR

MSR

S.7

@ < 4'-0" OPENINGS

@ 4'-0" TO 8'-0" OPENINGS

SCREWED JAMB WELDED JAMB

HEADER TO JAMB ASSEMBLY

TRACK SILL TO STUD ASSEMBLY

LOW HEADER TO STUD ASSEMBLY

WALL BRIDGING CHANNEL ASSEMBLY

STUD JAMB ASSEMBLY

ALTERNATIVESWALL ASSEMBLY AT FLOOR

WALL BUNDLE STUD

ASSEMBLY AT FLOOR BUNDLE STUD ASSEMBLY AT FLOOR

WALL INTERSECTION

BUNDLE STUD ASSEMBLY AT FLOOR

WALL CORNER

(2) 14 GA. JOIST HEADER

CONT. 14 GA. TRACK

WELDED JOINTS (TYP)

- SEE TYP. WALL

ASSEMBLY

FOR SIZE AND SPA.

CONT 14 GA. TRACK

- SEE CONNECTION

DETAILS

CONT HEADER - SEE

WALL SECTIONS

FOR LOCATION

CONT 14 GA. TRACK

- SEE CONNECTION

DETAILS

CONT 16 GA.

TRACK

- SEE CONNECTION

DETAILSTOP TRACK AND

HEADER

NOT FULLY SHOWN FOR

CLARITY OF ASSEMBLY

JAMB STUDS

L3x3x14 GA. CLIP

ANGLE

W/ (6) TEK SCREWS16 GA. TRACK

16 GA. STUD AND

TRACK

ASSEMBLY

16 GA. STUD SECTION

16 GA. STUD SECTION

16 GA. TRACK

16 GA. CR

CHANNEL

@ 4'-0" O.C. VERT.

16 GA. STUDS

W/ INDEXED

PUNCHOUTS

L3x3x14 GA. CLIP

ANGLE

W/ (4) TEK SCREWS

@ EACH STUD

GAUGE METAL FASTENERS TO BE #10 TEK SCREWS U.N.O.

GAUGE METAL FASTENERS TO BE 1/4

" TEK SCREWS U.N.O.

GAUGE METAL FASTENERS TO BE #10 TEK SCREWS U.N.O.

16 GA. STUDS

MIN. 16 GA. TRACK

AND CLIP ANGLE

MIN. # & OF SPACING OF TEK SCREWS REQUIRED PER ROW AT EACH

SIDE OF HEADER AND TRACK TO STUD CONNECTIONS:

12" DEPTH = 8 MIN. PER ROW @ 2" O.C. MAX. (16 TOTAL)

10" DEPTH = 6 MIN. PER ROW @ 2" O.C. MAX. (12 TOTAL)

8" DEPTH = 5 MIN. PER ROW @ 1 1/2" O.C. MAX. (10 TOTAL)

16 GA. JAMB STUDS

(2) @ 4'-0" MAX.

OPENING

(3) @ 4'-0" TO 8'-0" OPN'G

16 GA. TRACK

GAUGE METAL FASTENERS TO BE 1/4" TEK SCREWS @ 8" O.C. U.N.O.

3/4

" EPOXY ANCHOR

@ 32" O.C. - MIN. 10"

EMBED U.N.O.

WALL STUDS @ 16" O.C.

CONC FLOOR SLAB

3/4" EPOXY ANCHOR

@ 32" O.C. - MIN. 10"

EMBED U.N.O.

(4) 4SW14 STUDS

CONC FLOOR SLAB

3/4" EPOXY ANCHOR

EACH SIDE - MIN. 10"

EMBED U.N.O.

4SW14 STUDS

CONC FLOOR SLAB

3/4" EPOXY ANCHOR

EACH SIDE - MIN. 10"

EMBED U.N.O.

(4) 4SW14 STUDS

CONC FLOOR SLAB

1/8" 3"@8"

1/8" 3"@8"

TYP.

1/8" 1 1/2"

1/8" 1 1/2"

TYP. EA. STUD

1/8"

1/8"

1/8"

1/8"

TYP. EA. CLIP

1/8" 1 1/2"

1/8" 1 1/2"

TYP. EA. STUD

1/8" 3"@8"

1/8" 3"@8"

1/8"

TYP. EA. CLIP

1/8" 1 1/2"

1/8" 1 1/2"

TYP. EA. STUD

1/8" 3"@8"

1/8" 3"@8"

1/8" 3"@8"

1/8" 3"@8"

1/8" 1 1/2"

1/8" 1 1/2"

TYP. EA. STUD

1/8"

TYP. EA. CLIP

COLD FORMED HEADER TABLE

OPENING LENGTH HEADER SIZE JAMB SIZE

3'-0" TO 5'-0"

6'-0" TO 9'-0"

10-'-0" TO 12'-0"

(2) 600162-54 W/ 600T150-54 TOP AND BOTTOM

(2) 800162-54 W/ 600T150-54 TOP AND BOTTOM

(2) 1000162-54 W/ 600T200-54 TOP AND BOTTOM

(2) 600S162-54

(2) 600S162-54

(2) 600S162-68

NOTE:

HEADER AND JAMB SIZES PROVIDED ARE PRELIMINARY AND FOR BIDDING

PURPOSES ONLY. THE FINAL DESIGN IS THE RESPONSIBILITY OF THE

DESIGNATED COLD FORMED METAL FRAMING DESIGNER. REFER TO THE

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

C e tr o n ia R o a d S u it e n to w n

P

A

.4

.7

EMA-FIRE SCHOOL

DATE

T H

E C

O U

N T

Y O

F S

C H

U Y

L K

IL

L

M

N D

S T

R E

E T

P

O T

T S

V

IL

L E

P

A

DATE

Drawn By:

Y

K

IM

A R

C H

IT

E

C T

S

W

M a rk e t S tr e e t

P o tt s v ill e P

A

T

.6

.4 y k a a ia g m a il.

c o m

T H

E S

C H

U Y

L K

IL

L

C O

U N

T Y

E M

E R

G E

N C

Y S

E R

V

IC

E S

T R

A

IN

IN

G

F A

C

IL

IT

Y

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

F

IR

E M

E N

'S R

O A

D

F R

A C

K V

IL

L

E

P A

C O

L D

F O

R M

E D

M E

T A

L F

R A

M

IN

G D

E T

A

IL

S

JEB

MSR

MSR

S.8

FLOOR SLAB

0' - 0"

LOW ROOF STEEL

14' - 1 1/2"

A

BOT OF FT'G

-4' - 0"

3' - 0"

T.O. PARAPET

16' - 0"

4 1/2"

8" 4"

1' - 0" 1' - 0" 1' - 0"

(4) #5 CONT REBAR

#5 REBAR @ 18" O.C.

RAMMED AGGREGATE

PIER (DESIGN BY

OTHERS)

2B STONE COMPATED

TO DEPTH

1/2" THK PRE-MOLDED

EXPANSION JOINT MATERIAL

600S162-54 (MIN) METAL

STUDS @ 16" O.C.

CONT.

DEFLECTION

TRACK

L3x3x1/4 DIAGONAL

BRACE @ 48" O.C.

L5x5x1/4x2'-0" LONG FASTENED

TO ROOF DECK (3 LOCATIONS

MIN. W/ 1/4" TEK SCREWS

BAR JOIST (SEE PLAN)

ROOF BEAM

(PER PLAN)

CONT L4x4x1/4 ANGLE

3/8" THK CONN PLATE

ROOF DECK

TAPERED ROOF INSULATION

(SEE ARCH DWGS)

1/4"

3 SIDES (TYP

EA END)

#4 REBAR

@ 12" O.C.

EF

REINF. CONCRETE

FLOOR SLAB (SEE PLAN)

ENTRANCE

CANOPY

11' - 1 1/2"

2B STONE BASE

COMPACTED TO

6" THICK

#4 REBAR

@ 12" O.C.

RIGID CONNECTION

@ 16" O.C.

(BY COLD FORMED

DESIGNER)

FLOOR SLAB

0' - 0"

LOW ROOF STEEL

14' - 1 1/2"

A

BOT OF FT'G

-4' - 0"

Aa

4 1/2"

REINF REBAR, SEE

FOOTING SCHEDULE

REINF REBAR, SEE

FOOTING SCHEDULE

RAMMED AGGREGATE

PIER (DESIGN BY

OTHERS)

2B STONE COMPATED

TO DEPTH

1/2" THK PRE-MOLDED

EXPANSION JOINT MATERIAL

RAMMED AGGREGATE

PIER (DESIGN BY

OTHERS)

2B STONE COMPATED

TO DEPTH

(4) #5 CONT REBAR

#5 REBAR @ 18" O.C.

ENTRANCE

CANOPY

11' - 1 1/2"

HSS COLUMN

SEE S.6 FOR BASEPLATE

ANCHORAGE DETAILS

REINFORCED CONCRETE

PIER. SEE SCHEDULE

EXTERIOR CONCRETE

SLAB. SEE SITE PLAN

1' - 0" 1' - 0" 1' - 0"

8" 4"

CONT.

DEFLECTION

TRACK

L3x3x1/4 DIAGONAL

BRACE @ 48" O.C.

L5x5x1/4x2'-0" LONG FASTENED

TO ROOF DECK (3 LOCATIONS

MIN. W/ 1/4" TEK SCREWS

BAR JOIST (SEE PLAN)

ROOF BEAM

(PER PLAN)

CONT L4x4x1/4 ANGLE

3/8" THK CONN PLATE

ROOF DECK

TAPERED ROOF INSULATION

(SEE ARCH DWGS)

1/4"

3 SIDES (TYP

EA END)

COLD FORMED STEEL

HEADERS. SEE SCHEDULE

CANOPY

BEAM (PER

PLAN)

600S162-54 (MIN) METAL

STUDS @ 16" O.C.

600S162-54 (MIN) METAL

STUDS @ 16" O.C.

3' - 0" 10' - 4 1/2"

CANTILEVER

CANOPY BEAM

ROOF DECK

TAPERED INSULATION

CANOPY

BEAM (PER

PLAN)

600S162-54 (MIN) METAL

STUDS @ 16" O.C.

#4 REBAR

@ 12" O.C.

#4 REBAR @ 12" O.C. EF

2B STONE BASE

COMPACTED TO

8" THICK

RIGID CONNECTION @ 16" O.C.

(BY COLD FORMED DESIGNER)

/8

4" MASONRY VENEER

6" CMU W/ ADJUSTABLE

MASONRY TIES @ 24" O.C.

C e tr o n ia R o a d S u it e n to w n

P

A

.4

.7

EMA-FIRE SCHOOL

DATE

T H

E C

O U

N T

Y O

F S

C H

U Y

L K

IL

L

M

N D

S T

R E

E T

P

O T

T S

V

IL

L E

P

A

DATE

Drawn By:

Y

K

IM

A R

C H

IT

E

C T

S

W

M a rk e t S tr e e t

P o tt s v ill e P

A

T

.6

.4 y k a a ia g m a il.

c o m

T H

E S

C H

U Y

L K

IL

L

C O

U N

T Y

E M

E R

G E

N C

Y S

E R

V

IC

E S

T R

A

IN

IN

G

F A

C

IL

IT

Y

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

F

IR

E M

E N

'S R

O A

D

F R

A C

K V

IL

L

E

P A

W A

L L S

E C

T

IO

N S

JEB

MSR

MSR

S.9

01/09/25

3/4" = 1'-0"

WALL SECTION

3/4" = 1'-0"

WALL SECTION

8"

8"

8"

LOW ROOF STEEL

14' - 1 1/2"

BOT OF FT'G

-4' - 0"

T.O. PARAPET

16' - 0"

8" 4"

3' - 0"

4 1/2"

(4) #5 CONT REBAR

#5 REBAR @ 18" O.C.

RAMMED AGGREGATE

PIER (DESIGN BY

OTHERS)

2B STONE COMPATED

TO 8" DEPTH

1/2" THK PRE-MOLDED

EXPANSION JOINT MATERIAL

600S162-54 (MIN) METAL

STUDS @ 16" O.C.

CONT.

DEFLECTION

TRACK

L3x3x1/4 DIAGONAL

BRACE @ 48" O.C.

BAR JOIST

(SEE PLAN)

ROOF BEAM

(PER PLAN)

3/8" THK

CONN PLATE

ROOF

DECK

TAPERED ROOF INSULATION

(SEE ARCH DWGS)

1/4"

3 SIDES (TYP

EA END)

#4 REBAR @

12" O.C. EF

REINF. CONCRETE

FLOOR SLAB (SEE PLAN)

1' - 0" 1' - 0" 1' - 0"

3/8" THK CONN

PLATE

CONT HSS5x2 1/2x1/8

(LSH)

CONT TRACK

TOP & BOT

RIGID CONNECTION @ 16" O.C.

(BY COLD FORMED DESIGNER) 600S162-54 (MIN) METAL

STUDS @ 16" O.C.

2B STONE BASE

COMPACTED TO

8" THICK

3-12

3-12

#4 REBAR

@ 12" O.C.

FLOOR SLAB

0' - 0"

F

BOT OF FT'G

-4' - 0"

HIGH ROOF STEEL

18' - 5 1/2"

ROOF BEAM

(PER PLAN)

ROOF

DECK

TAPERED ROOF INSULATION

(SEE ARCH DWGS)

CONT TRACK

TOP & BOT

RIGID CONNECTION @ 16" O.C.

(BY COLD FORMED DESIGNER)

600S162-54 (MIN) METAL

STUDS @ 16" O.C.

CONT.

DEFLECTION

TRACK

L3x3x1/4 DIAGONAL

BRACE @ 48" O.C.

BAR JOIST

(SEE PLAN)3/8" THK

CONN PLATE 1/4"

3 SIDES (TYP

EA END)

3/8" THK CONN

PLATE

600S162-54 (MIN) METAL

STUDS @ 16" O.C.

BUILT-UP BOX HEADER.

SEE SCHEDULE ON S.8

1' - 0" 1' - 0" 1' - 0"

3' - 0"

9" 3"

1.95%

SLOPE - SEE

ARCH DWGS

(4) #5 CONT REBAR

#5 REBAR @ 18" O.C.

RAMMED AGGREGATE

PIER (DESIGN BY

OTHERS)

2B STONE COMPATED

TO 8" DEPTH

#4 REBAR @

12" O.C. EF 2B STONE BASE

COMPACTED TO

8" THICK

#4 BENT REBAR

@ 12" O.C.

#4 REBAR @ 12" O.C.

FLOOR SLAB

0' - 0"

LOW ROOF STEEL

14' - 1 1/2"

HSS COLUMN - SEE

PLAN AND SCHEDULE

RAMMED AGGREGATE

PIER (DESIGN BY

OTHERS)

2B STONE COMPATED

TO 8" DEPTH

1/2" THK PRE-MOLDED ISOLATION

JOINT MATERIAL

ROOF BEAM

(PER PLAN)

ROOF DECK

TAPERED ROOF INSULATION

(SEE ARCH DWGS)

REINF. CONCRETE

FLOOR SLAB (SEE PLAN)

ROOF BEAM

(PER PLAN)

CONT HSS5x2 1/2x1/8

(LSH)

3-12

3-12

MOMENT CONNECTION

SEE DETAILS ON S.7

COLUMN FOOTING -

SEE TYPICAL INTERIOR

FOOTING DETAIL ON S.6

C e tr o n ia R o a d S u it e n to w n

P

A

.4

.7

EMA-FIRE SCHOOL

DATE

T H

E C

O U

N T

Y O

F S

C H

U Y

L K

IL

L

M

N D

S T

R E

E T

P

O T

T S

V

IL

L E

P

A

DATE

Drawn By:

Y

K

IM

A R

C H

IT

E

C T

S

W

M a rk e t S tr e e t

P o tt s v ill e P

A

T

.6

.4 y k a a ia g m a il.

c o m

T H

E S

C H

U Y

L K

IL

L

C O

U N

T Y

E M

E R

G E

N C

Y S

E R

V

IC

E S

T R

A

IN

IN

G

F A

C

IL

IT

Y

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

F

IR

E M

E N

'S R

O A

D

F R

A C

K V

IL

L

E

P A

W A

L L S

E C

T

IO

N S

JEB

MSR

MSR

S.10

01/09/25

3/4" = 1'-0"

WALL SECTION

3/4" = 1'-0"

WALL SECTION

3/4" = 1'-0"

WALL SECTION

BOT OF FT'G

-4' - 0"

H G

CANOPY STEEL

10' - 8 1/8"

RAMMED AGGREGATE

PIER (DESIGN BY

OTHERS)

2B STONE COMPATED

TO 8" DEPTH

HSS COLUMN - SEE ARCH.

FOR FINISH AND

ENCASEMENT

SEE S.6 FOR BASEPLATE

ANCHORAGE DETAILS

REINFORCED CONCRETE

PIER. SEE SCHEDULE

CANOPY BEAM

(PER PLAN)

REINF REBAR, SEE

FOOTING SCHEDULE

RAMMED AGGREGATE

PIER (DESIGN BY

OTHERS)

2B STONE COMPATED

TO 8" DEPTH

CANOPY BEAM

(PER PLAN)

HSS COLUMN - SEE ARCH.

FOR FINISH AND

ENCASEMENT

SEE S.6 FOR BASEPLATE

ANCHORAGE DETAILS

REINFORCED CONCRETE

PIER. SEE SCHEDULE

SEE CIVIL SITE PLANS FOR

FINISHED GROUND LINE

20' - 0"

REINF REBAR, SEE

FOOTING SCHEDULE

CONT TRACK

TOP & BOT

RIGID CONNECTION @ 16" O.C.

(BY COLD FORMED DESIGNER)

BUILT-UP BOX HEADER

(BY COLD FORMED

DESIGNER)

600S162-54 (MIN) METAL

STUDS @ 16" O.C.

ROOF

DECK

TAPERED ROOF INSULATION

(SEE ARCH DWGS)

6 5/8"

FLOOR SLAB

0' - 0"

BOT OF FT'G

-4' - 0"

HIGH ROOF STEEL

18' - 5 1/2"

ROOF BEAM

(PER PLAN)

ROOF

DECK

TAPERED ROOF INSULATION

(SEE ARCH DWGS)

CONT TRACK

TOP & BOT

RIGID CONNECTION @ 16" O.C.

(BY COLD FORMED DESIGNER)

600S162-54 (MIN) METAL

STUDS @ 16" O.C.

CONT.

DEFLECTION

TRACK

BAR JOIST

(SEE PLAN)

7 1/4"

#5 REBAR DOWEL

@ 48" O.C.

6" CMU

3000PSI SOLID GROUT FILL AT

ALL REINFORCEMENT CORES

FULL HEIGHT

CONT HORIZONTAL LADDER

TYPE JOINT REINF. - 9 GA.

GALV STEEL @ 16" O.C. VERT

(4) #5 CONT REBAR

#5 REBAR @ 18" O.C.

RAMMED AGGREGATE

PIER (DESIGN BY

OTHERS)

2B STONE COMPATED

TO 8" DEPTH

#4 REBAR @

12" O.C. EF 2B STONE BASE

COMPACTED TO

8" DEPTH

REINF. CONCRETE GARAGE

BAY FLOOR - SEE ARCH

DWGS FOR SLOPE

3' - 0"

MASONRY VENEER - SEE

ARCH DWG

ADJUSTABLE BRICK TIES

@ 16" O.C. E.W.

1' - 0" 1' - 0" 1' - 0"

9" 3"

600S162-54…

This is the start of the file's text. The full file is on GovTribe.