3-250528 SCESTF-Arch Plans.pdf

PDF 1 MB Posted

Attached to
Schuylkill County - Emergency Training Facility (0325-900015.01)
Solicitation number
US.251947
Issued by
Somerset County, Pennsylvania

About this file

This file contains architectural plans for the Schuylkill County Emergency Training Facility construction project in Pennsylvania. The project is being procured through sealed bids via the PennBid Program by the Schuylkill County Controller, with bids due by Wednesday, October 21, 2026, at 9:00 AM. The construction work is divided into four separate prime contracts: General Construction (Contract No. 1), Plumbing Construction (Contract No. 2), HVAC Construction (Contract No. 3), and Electrical Construction (Contract No. 4). The tentative award date is Wednesday, October 28, 2026. All bidding documents are available at no cost through the PennBid online portal at http://PennBid.bonfirehub.com, with technical support available from PennBid at info@pennbid.net or 610-693-4769.

Bid security in the form of a certified check, bank draft, or satisfactory bid bond equal to 10 percent of the total bid amount must accompany each submission. The successful bidder will be required to provide Performance and Payment Bonds, each in the amount of 100 percent of the contract price, executed by an acceptable corporate surety approved by the County. Davis-Bacon wage rates apply to this contract. The Owner reserves the right to waive informalities, reject any or all items, or reject any or all bids in the best interest of the County. Contractors must comply with nondiscrimination requirements regarding race, age, color, religion, sex, national origin, and handicap status for employees and applicants.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THE BOARD OF THE COMMISSIONERS

THE COUNTY OF SCHUYLKILL

401 N.2nd Street, Pottsville, PA 17901

NEW CONSTRUCTION OF

Firemen's Road, Frackville, PA

Y. KIM ARCHITECTS

729 W. Market Street, Pottsville, PA 17901

T. 570.628.4584

PROJECT INFORMATION

CODE REFERENCES

OCCUPANCY GROUP

CONSTRUCTION TYPE

INTERNATIONAL

BUILDING CODE 2018

Business Group (B)

Type: III‐B

[Business @ 150 SF (gross) for 8,200 SF=54 Occupants

HEIGHT & FLOOR AREA LIMIT

for Construction Type: III‐B

REQUIRED : One (1 Story) :

19,000 S.F. per Floor

THIS PROJECT :

One (1) Story / 14,080 S.F.

ACCESSIBLE & USABLE

BUILDINGS

& FACILITIES [ICC A117.1‐2017]

APPROVALS

SCHUYLKILL COUNTY

EMERGENCY SERVICES TRAINING FACILITY

May 28, 2025

LIST OF DRAWINGS

CS TITLES, PROJECT INFORMATION,

LIST OF DRAWINGS & NOTES

A.1 FLOOR PLAN, KEY PLAN & WALL TYPES

A.2 REFLECTED CEILING PLAN & OPERABLE PARTITION TRACK DETAIL

A.3 ROOF PLANS

A.4

A.5.1 PLAN DETAILS

EXTERIOR ELEVATIONS & TYP. WINDOW ELEVATION

LOCATION PLAN

H.1.1 FLOOR PLAN‐HVAC

H.2.1 HVAC‐ROOF PLAN

CONSOLIDATED ENGINEERS

1022 James Drive, Leesport, PA 19533

T. 610.916.1600

Bearing Walls

Number of Hours Req'd

Not Applicable

Building Element

Primary Structural Frame 0 Hour

‐Exterior

‐Interior

Non‐Bearing Walls ‐Exterior

‐Interior

FIRE‐RESISTANCE RATING

Larry J. Padora, Jr., Chairman

Barron L. Hetherington, Commissioner

Gary J. Hess, Commissioner

Gary R. Bender, County Administrator

Alvin Marshall, County Solicitor

Lisa Mahall, Director of Real Estate & County Engineer

Kevin Mahall, Director of Public Works

Frank Zangari, President Schuylkill County Fire Chief's Association

John Blickley, Director, County EMASharyn Yackenchick, County Controller

E. 1.1

E. 2.1 FLOOR PLAN‐LIGHTING

E. 2.2 FLOOR PLAN‐POWER

ELECTRICAL SITE PLAN

E. 3.1

Not Applicable

Not Applicable

BENESCH & COMPANY

400 One Norwegian Plaza, Pottsville, PA 17901

T. 570.622.4055

Roof above Roof Deck

Total

Fibrous

THERMAL ENVELOPE INSULATION [R‐VALUE]

Polyiso (Flat)

R‐30

R‐21

R‐14 *

R‐6

R‐24

Exterior Walls above Fin. Fl.

Perimeter Insulation.

[* W/ Galvanized "Z" Clips]

ROOF PLAN‐POWER

Polyiso

Polyiso (Sloped)

S.1 GENERAL NOTES

S.2 FOUNDATION PLAN

S.3 LOW ROOF FRAMING PLAN

S.4

S.5 TYPICAL CONCRETE DETAILS

HIGH ROOF FRAMING PLAN

S.6 CONCRETE & MASONRY DETAILS

S.7

S.8 COLD FORMED METAL FRAMING DETAILS

0 Hour

[Meeting Area @ 15 SF(net) for 2,736 SF=182 Occupants

[Garage @ 200 SF(gross) for 3,200 SF=16 Occupants

[Total Occupants: [252]

[16]

[182]

[54]

David Sattizahn, President Schuylkill County Volunteers Firefighters Association

E. 4.1 POWER RISER DIAGRAM

E. 5.1 SYMBOL LEGEND

E. 5.2 FIXTURE SCHEDULE & NOTES

E. 5.3 PANEL SCHEDULE

P.4.1 PLUMBING SCHEDULES

P.3.1 PLUMBING DETAILS

P.2.1 FOUNDATION PLAN ‐ PLUMBING

P.1.1 FLOOR PLAN ‐ PLUMBING

H.3.1 HVAC‐DETAILS

H.3.2 HVAC‐DETAILS

H.4.1 HVAC‐SCHEDULES

S.9 WALL SECTIONS

S.10

S.11

WALL SECTIONS

WALL SECTIONS

A.5.2 COLUMN DETAILS & DOOR JAMB DETAILS

A.5.3 TYP. EXTERIOR WALL SECTION, O.H DOOR JAMBS & DETAILS

A.5.4

A.6.1 INTERIOR FINISH SCHEDULE, DOOR SCHEDULE &

FRONT ENTRANCE DETAILS

GARAGE WALL SECTIONS, FRONT CANOPY SECTION & DETAILS

A.6.3 ROOF DETAILS

1 COVER SHEET

2 GENERAL NOTES

3 EXISTING CONDITIONS& DEMOLITION

PLAN AND SUBDIVISION PLAN

5 GRADING & UTILITY PLAN

SITE LAYOUT PLAN

6 STORM SEWER PROFILE

8‐10

CONSTRUCTION DETAILS

ERROSION & SEDIMENT POLUTION

CONTROL PLAN

11‐12

POST CONSTRUCTION

STORMWATER MANAGEMENT PLAN

14‐15 POST CONSTRUCTION

STORMWATER MANAGEMENT PLAN

DETAILS

LAND DEVELOPMENT PLAN FOR CONSTRUCTION

ERROSION & SEDIMENT POLUTION

CONTROL DETAILS

STRUCTURAL STEEL DETAILS

RESTROOM ENLARGED PLANS & ELEVATIONS,

TOILET ACCESSORIES & CABINET DETAILS

A.6.2

INDUSTRIAL ROAD

MOREA ROAD

PROJECT SITE

FIREM

EN

'S RO

AD

INTERSTATE 81

N

MOREA

R

OAD

CRPT

CB

B/C

CLG

ALUM

BP

ALT

B & B

CH. BD

A/E

AFF

CLG. HGT

BRDG

CLO

ANOD

APPROX

ARCH

AV

BUR

BD

CMT

CEM. PLAS

BITUM

BLDG

CER

CF

BLK

AB

CG

CAB

CI

CJ

BLKG

AC

C/L

BLKHD

CMU

CO

COL

ACOUS

CONC

BLVD

BM

ACT

BOT

AD

BRG. PL

BSMT

BU

X

C/C

ADJN

AHU

ALUM

L

ABBREVIATIONS

AND

CARPET

CATCH BASIN

CEILING

BOTTOM OF CURB

ALUMINUM

AIR HANDLING UNIT

ALTERNATE

CEILING HEIGHT

BRIDGING

BALLED & BURLAPPED

CHALK BOARD

AT

ANGLE

BOARD

CEMENT

CEMENT PLASTER

BITUMINOUS

CERAMIC

BUILDING

BLOCK

ANCHOR BOLT

COPPER FABRIC

CABINET

CORNER GUARD

CAST IRON

ARCHITECT/ENGINEER

CONTROL JOINT

AIR CONDITIONING

CENTER LINE

BLOCKING

BULKHEAD

CLOSET

CONCRETE MASONRY UNIT

CLEANOUT

COLUMN

ACOUSTICAL

BOULEVARD

CONCRETE

BEAM

ACOUSTICAL CEILING TILE

BOTTOM

AREA DRAIN

BEARING PLATE

BASEMENT

ADJUSTABLE

BUILT‐UP

BUILT‐UP ROOFING

BY (AS IN 2 X 4)

CENTER TO CENTER

ADJACENT

ABOVE FINISHED FLOOR

ANODIZED

APPROXIMATE(LY)

ARCHITECT(URAL)

AUDIO‐VISUAL

ALUMINUM

BASE PLATE

ADJST

CSMT

ENCL

C

D

DAT

DBL

DEMO

DEPT

EMER

E

EA

EC

EF

EIFS

EL

ELEC

ELEV

DTL

ENGR

EP

EPDM

DTL

DH

DIA

DIM

DISP

DL

DMPF

DN

DS

DW

DWG

EQ

EQUIP

EW

EWC

EXH

EXP

EXIST

EXT

EXCAV

CONN

CONST

CONTR

CONT

CORR

CP

CRS

CS

CSNK

CF

CT

CY

CW

CHANNEL

DRYER

DATUM

DOUBLE

DEMOLITION

DEPARTMENT

DETAIL

DRAWING

EAST

EACH

ELECTRICAL CONTRACTOR

EACH FACE

FINISH SYSTEM

CASEMENT

CONNECTION/CONNECTED

CONSTRUCTION

CONTRACTOR

CONTINUOUS

CORRIDOR

CONCRETE PIPE

COLD ROLLED STEEL

COURSES

COUNTER SINK

EXTERIOR INSULATION

ELEVATION

ELECTRIC(AL)

ELEVATOR

DETAIL

EMERGENCY

ENCLOSURE

ENGINEER

ELECTRIC PANEL

DOUBLE HUNG

DIAMETER

DIMENSION

DISPENSER

DEAD LOAD

DAMPPROOFING

DOWN

DOWNSPOUT

DISHWASHER

EQUAL

EQUIPMENT

EACH WAY

ELECTRIC WATER COOLER

EXHAUST

EXPANSION

EXISTING

EXTERIOR

EXCAVATE(ED) (ION)

ETHYLENE PROPYLENE

DIENE MONOMER

COLD WATER

CUBIC YARD

CUBIC FOOT

CERAMIC TILE

GND

FEC

FH

FIN

FL

FLUOR

FT

FTG

HEX

GL

FURN

FURR

G

GR

GYP

GWB

HTR

HB

HDWD

HDWR

HGT

HM

HORZ

HP

INCAND

HTG

HVAC

HW

HYD

JC

ID

JT

GA

FE

GALV

GB

GEN

GC

GFI

IN

INSUL

INT

INV

IP

HB

JAN

JST

HGT

FA

FACP

FD

FDN

GLASS

GRADE

FIRE HYDRANT

GAS

CABINET

FIRE EXTINGUISHER

FINISH(ED)

FLOOR

FLUORESCENT

FOOT/FEET

FOOTING

INTERRUPED

GROUND FAULT

FURNISH(ED)

FURRING

GYPSUM

GYPSUM WALL BOARD

HEATING

HOSE BIB

HARD WOOD

HARDWARE

HEIGHT

HOLLOW METAL

HORIZONTAL

HIGH POINT

INTERIOR

HEATER

HEATING VENTILATING

AIR CONDITIONING

HYDRANT

JANITOR

INSIDE DIAMETER

JOINT

GAUGE

GALVANIZED

GRAB BAR

GENERAL

GENERAL CONTRACTOR

HEXAGONAL

GROUND

INCH

INCANDSCENT

INSULATION

INVERT

IRON PIPE

HOSE BIB

JANITOR'S CLOSET

JOIST

FIRE EXTINGUISHER

FIRE ALARM

CONTOL PANEL

FIRE ALARM

FLOOR DRAIN

FOUNDATION

LF

K

KCP

KO

LLH

LAB

LP

LAM

LAV

LTG

LB / #

L/C

LG

LH

LL

LT WT

MAINT

MAS

LLV

MIN

MISC

MLDG

MO

MAT

MAX

MCB

MECH

MET

MEZZ

MFR

MH

NOM

NTS

O/O

MR

OA

MTD

N

NRC

NIC

OBS

OC

OD

OPNG

OPP

OSB

OZ

MTG

MULL

NO

LIGHT GAUGE

KIP (1,000 LB)

KEENES CEMENT PLASTER

KNOCK OUT

LABORATORY

LONG LEG VERTICAL

LAMINATE(D)

LAVATORY

POUND

LOW POINT

MEZZANINE

LINEAR FOOT

LEFT HAND

LIVE LOAD

LIGHT WEIGHT

LIGHTING

MAN HOLE

MAINTENANCE

LONG LEG HORIZONTAL

MINIMUM

MASONRY

MOLDING

MASONRY OPENING

NUMBER

MATERIAL

MAXIMUM

METAL CORNER BEAD

MECHANICAL

METAL

MANUFACTURER

MISCELLANEOUS

NOMINAL

LIMIT OF CONTRACT

NOT TO SCALE

OUNCE

MISTURE RESISTANT

OVER ALL

MOUNTED

NORTH

NOISE REDUCTION

COEFFICIENT

NOT IN CONTRACT

OPPOSITE

OUT TO OUT

OBSCURE

ON CENTER

OUTSIDE DIAMETER

OPENING

BOARD

ORIENTED STRAINED

MOUNTING

MULLION

PLAS

PNL

PTN

PC

PERF

POL

PERM

PERP

PL

PSF

PLAM

PLBG

PLYWD

PMF

POLYISO

PREFAB

PRELIM

PSI

RAD

RCP

PTD

PVC

RD

QT

REINF

RECPT

QTY

REF

R

RH

RM

RO

R/W

RT

RUB

RWC

RWL

S

SF

REQD

REV

SI

SY

SS

REG

SAN

SCH

SECT

SHT

SHTHG

SIM

SPEC(S)

SPKLR

SPKR

SQ

PARTITION

PLUMBING CONTRACTOR

PERFORATED

POLISHED

PERIMETER

PERPENDICULAR

PLATE

PRELIMINARY

PANEL

PLUMBING

PLYWOOD

PREMOLDED FILLER

QUANTITY

POLYISOCIANURATED

PREFABRICATED

POUND PER SQUARE FOOT

POUND PER SQUARE INCH

RADIUS

REINFORCED CONCRETE

PAINTED

POLYVINYL CHLORIDE

ROOF DRAIN

QUARRY TILE

REINFORCED

RECEPTACLE

REFRIGERATOR

RISER

RIGHT HAND

ROOM

RIGHT OF WAY

ROUGH OPENING

RESILIENT TILE

RUBBER

RAIN WATER CONDUCTOR

RAIN LEADER

SOUTH

REGISTER

REQUIRED

REVISION/ REVISED

SQUARE FOOT

SQUARE INCH

SQUARE YARD

SERVICE SINK

PLASTIC LAMINATE

PLASTER

PIPE

SANITARY

SCHEDULE(D)

SECTION

SHEET

SHEATHING

SIMILAR

SPECIFICATION(S)

SPRINKLER

SPEAKER

SQUARE

TERZ

T

ST STL

STA

ST

STC

STD

STL

STOR

STRUCT

SUSP

THK

THRHLD

THRU

TEMP

T & B T & G

TB

TOB

SHT

TOS

TOC

TEL

TYP

WD

VERT

UH

UL

UNEXC

UNO

TV

VENT

UC

VEST

UNFIN

W/O

V

VCT

VCP

VWC

W W/

WC

WCO

WF

WG

WH

W/H

WTRPRF

WSCT

WT

WWF

TPO

STAINLESS STEEL

STATION

STREET

SOUND TRANSMISSION

COEFFICIENT

STANDARD

STEEL

STORAGE

STRUCTURE(AL)

TERRAZZO

THICK(NESS)

THRESHHOLD

THROUGH

TREAD

TEMPERED

TOP & BOTTOM

TONGUE & GROOVE

TACKBOARD

TOP OF BEAM

TELEPHONE

TOP OF STEEL

TOP OF CONCRETE

SUSPENDED

UNEXCAVATED

TELEVISION

TYPICAL

UNIT HEATER

UNDER WRITERS LABORATORY

UNDERCUT

VERTICAL

VESTIBULE

UNLESS NOTED OTHERWISE

UNFINISHED

VENT

VINYL COMPOSITION TILE

VINYL WALL COVERING

WATER HEATER

WEST

WITH

WITHOUT

WATER CLOSET

WELDED WIRE FABRIC

VITRIFIED CLAY PIPE

WOOD

WIDE FLANGE

WALL GUARD

WALL HYDRANT

WATERPROOFING

WAINSCOT

VENTILATOR

WEIGHT

WALL CLEANOUT

THERMOPLASTIC

OLEFIN

HOT WATER

DATE

TH

E

C O

U N

TY

O

F

SC

H U

Y

LK

IL

L

M

2N D

S

TR

EE

T, P O

TT

SV

IL

LE

, P A

DATE

Drawn By:

Y.

K

IM

A

RC

H

IT

EC

TS

W . M ar ke t St re et

Po tt sv ill e, P

A

T.

.6

.4 yk aa ia gm ai l.c om

T H

E

SC

H U

Y

LK

IL

L

C O

U N

TY

EM

ER

G

EN

CY

S

ER

V

IC

ES

T

RA

IN

IN

G

F A

CI

LI

TY

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

FI

R

EM

EN

'S R

O A

D , F

R A

CK

V

IL

LE

, P A yK yK2

A.

EMAFS

E

INTERIOR

WALL TYPES

1/2" GYP. WALL BOARD

6" STEEL STUDS

@ 16"O.C.

W/ 3‐1/2" INSUL.

1/2" GYP. WALL BOARD

F

1. ALL GYPSUM WALLBOARDS SHALL BE TYPE"X" AND MOISTURE RESISTANT WALLBOARDS AT ALL RESTROOMS.

2. ALL BOTTOM & TOP TRACKS OF METAL STUDS SHALL BE INSTALLED ON ACOUSTICAL SEALNT.

3. ALL PARTITIONS SHALL BE EXTENDED TO UNDERSIDE OF ROOF TRUSSES, AS SHOWN IN DETAILS DRAWINGS.

4. REINFORCING OF CMU SHALL BE #5 BARS IN FILLED CORE AT 4' O.C. AND HORIZONTAL REINFORCING (DUR‐O‐WAL)

AT 24" O.C.

G

1/2" GYP. WALL BOARD

2‐1/2" STEEL STUDS

@ 16"O.C.

8" REINF.CMU

1/2" GYP. WALL BOARD

6" STEEL STUDS

@ 16"O.C.

W/6" INSUL.

2 LAYERS

1/2" GYP. WALL BOARD

HA

1/2" GYP. WALL BOARD

3‐1/2" STEEL STUDS

@ 16"O.C.

W/ 3‐1/2" INSUL.

2 LAYERS

1/2" GYP. WALL BOARD

B C

1/2" GYP. WALL BOARD

6" STEEL STUDS

@ 16"O.C.

W/ 6" INSUL.

1/2" GYP. WALL BOARD

1/2" GYP. WALL BOARD

3‐1/2" STEEL STUDS

@ 16"O.C.

W/ 3‐1/2" INSUL.

1/2" GYP. WALL BOARD

D

1/2" GYP. WALL BOARD

3‐1/2" STEEL STUDS

12" CAVITY (NTS)

3‐1/2" STEEL STUDS

1/2" GYP. WALL BOARD

12"

CAVITY

(NTS)

8" REINF.CMU

4'6"12'0" 12'0"

'0

'0

'0

'0

20'0" 20'0" 24'0" 24'0" 24'0" 24'0" 40'0"

5'

5'0"

8'

11'6" 11'6" 23'0" 11'6" 11'6"

20'0" 20'0" 24'0"

24'0" 24'0" 24'0" 40'0"

'0

'0

'0

'0

'0

6'

/2

12'0"

8"

24'0"

5'

'3

/4

8'0" 8'

15'6" 15'2"

5'0"

'9

11'4"

1'0"

'0

'0

E A

B

B B H

G H

H

B

H F

B

E

B

B

BB

B

B

B

F

F

B

BC

D C

E

E

B

E

C D

G

A

A

A

A

A

A

A C

C

A

C

A A

A F

A

A

A

A

A

IT ROOM

/106

OFFICE

BREAK

ROOM

/114

OPERATION ROOM

/103

STORAGE

/205

TRAINING

/204

(900 SF)

MEN'S

/206

COVERED PARKING AREA

1 2 3 4 5

1 2 3 6 7 8 9

C

A

E

F

C'

B

D

1 2 3 5 6 7

8 9

TRAINING/203

(900 SF)

TRAINING

/202

(900 SF)

GARAGE

/300

CORRIDOR

/200

STORAGE

/209

MECHANICAL

ROOM/211

OFFICE

/112

OFFICE

/111

OFFICE

/110

OFFICE

/109

OFFICE

/108

OFFICE

/107

C

A

E

F

B

D

JAN.

/118

LADIES'

/208

VESTIBULE

/100

4 5 5'

Aa

LOBBY

/101

RECEPTION

/105

ELECTRICAL

ROOM

(S

LO

PE

(L

EV

EL

(S

LO

PE

CO

RR

ID

O

R /2

CO

RR

ID

O

R /1

107 101

105106

A

HALL/102

HALL/104

CO

RR

ID

O

R /1

112 113 114

A

202 203 204

200 300

VEND.

/207

210 210 A

A

A

A

A

B

C

D

E

F

G

H

LADIES'

/117

MEN'S

/119

STORAGE

/210

C.W.

H.W.

EW

C

EW

C

#1

A.1

1 FLOOR PLAN

1/8"=1' 0"

FE

FEFE FE

FE

FE

FE

FE

FE

FE

G

H

1 2' 3' 5"

A

.5 .4

CONCRETE FILLED (ROUND TOP) STEEL PIPE

BOLLARD (8" DIA.). 8 FT. TOTAL: 4 FT. UNDERGROUND

& 4 FT. ABOVE GROUND

A.5.2

A.5.2

A.5.2

A

.5 .4

A.5.3

A

.5 .3

A

.5 .31

A .5

.2

A

.5 .2 1

A .5

.2

A

.5 .3 1

A .5

.2

A

.5 .4

2.1 A.5.4

A

.5 .4

FL

O

O R P

LA

N

IN

TE

R

IO

R W

A

LL

T

YP

ES

5/28/25

E

C O

U N

TY

O

F

SC

H U

Y

LK

IL

L

M

2N D

S

TR

EE

T, P O

TT

SV

IL

LE

, P A

DATE

Drawn By:

Y.

K

IM

A

RC

H

IT

EC

TS

W . M ar ke t St re et

Po tt sv ill e, P

A

T.

.6

.4 yk aa ia gm ai l.c om

T H

E

SC

H U

Y

LK

IL

L

C O

U N

TY

EM

ER

G

EN

CY

S

ER

V

IC

ES

T

RA

IN

IN

G

F A

CI

LI

TY

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

FI

R

EM

EN

'S R

O A

D , F

R A

CK

V

IL

LE

, P A yK yK2

A.

EMAFS

'0

'0

71'0"

WIND‐LOK SOFFIT BY "ATAS",

.032 ALUM. STUCCO EMBOSSED

TEXTURE OR APPROVED EQUIVALENT

BY OWNER.

WIND‐LOC SOFFIT.

WIND‐LOK SOFFIT BY "ATAS",

.032 ALUM. STUCCO EMBOSSED

TEXTURE OR APPROVED EQUIVALENT

BY OWNER.

A.2

1 REFLECTED CEILING PLAN

1/8"=1' 0"

1 9

A

F

A

F

G

H

2' 3' 5"

A.2

A.2

SUSPENDED ACT

(9' 0" AFF.)

DROPPED SOFFIT TRIM

TRACK &

TROLLEYS

OPERABLE PARTITION

AUTOMATIC

TOP SEAL

STRUCTURAL

SUPPORT

HANGER RODS

2 LAYERS OF

GYPSUM BOARD (1/2")

TO UNDERSIDE

OF ROOF DECK

W/ ACOUSTIC SEALANT

AT ALL GAPS (TYP.)

A.2

DETAIL‐OPERABLE PARTITION

1‐1/2"=1' 0"

R

EF

LE

C

TE

D C

EI

LI

N G

P

LA

N

O

PE

R A B

LE

P A R

TI

TI

O

N

TR

A C K D

ET

A

IL

E

C O

U N

TY

O

F

SC

H U

Y

LK

IL

L

M

2N D

S

TR

EE

T, P O

TT

SV

IL

LE

, P A

DATE

Drawn By:

Y.

K

IM

A

RC

H

IT

EC

TS

W . M ar ke t St re et

Po tt sv ill e, P

A

T.

.6

.4 yk aa ia gm ai l.c om

T H

E

SC

H U

Y

LK

IL

L

C O

U N

TY

EM

ER

G

EN

CY

S

ER

V

IC

ES

T

RA

IN

IN

G

F A

CI

LI

TY

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

FI

R

EM

EN

'S R

O A

D , F

R A

CK

V

IL

LE

, P A yK yK2

A.

EMAFS

'0

'0

'0

18'0"50'1/2"

'0

'0

1 2 3 6 7 8 9

C

A

E

F

B

D

3 4 5 5'

1 2 3 6

7 8 9

3 4 5 5'

N

TO FIREMEN'S ROAD

RD

1 ROOF PLAN

1/8"=1' 0"

A.3 1/8"=1' 0"

RD

RD RD

OS

OS

OSOS

OSOS

RD: ROOF DRAIN

OS: OVERFLOW SCUPPER

RDOS

G

H

RD RD

OS

SLOPESLOPE

SL

O

PE

SL

O

PE

SLOPESLOPE

SL

O

PE

SL

O

PE

SLOPESLOPE

SL

O

PE

SL

O

PE

SLOPESLOPE

SL

O

PE

SL

O

PE

SLOPESLOPE

SL

O

PE

SL

O

PE

SLOPESLOPE

SL

O

PE

SL

O

PE

2' 3' 5"

1 2 33 4 5 5'

RD

RD

SLOPE SLOPE

SL

O

PE

SL

O

PE

SLOPE SLOPE

SL

O

PE

SL

O

PE

RD

RD

SLOPESLOPE

SL

O

PE

SL

O

PE

SLOPESLOPE

SL

O

PE

SL

O

PE

A.5.4

A

.5 .4

A.5.4

A

.5 .4

A

.5 .4

A

.5 .4

R O

O F

PL

A N

S

E

C O

U N

TY

O

F

SC

H U

Y

LK

IL

L

M

2N D

S

TR

EE

T, P O

TT

SV

IL

LE

, P A

DATE

Drawn By:

Y.

K

IM

A

RC

H

IT

EC

TS

W . M ar ke t St re et

Po tt sv ill e, P

A

T.

.6

.4 yk aa ia gm ai l.c om

T H

E

SC

H U

Y

LK

IL

L

C O

U N

TY

EM

ER

G

EN

CY

S

ER

V

IC

ES

T

RA

IN

IN

G

F A

CI

LI

TY

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

FI

R

EM

EN

'S R

O A

D , F

R A

CK

V

IL

LE

, P A yK yK2

A.

EMAFS

2'8"

5'

1'

0" 2"

3'

PROJECT OUT

(1" INSULATING

GLASS)

FIXED

(1" INSULATING

GLASS)

SILL TRIM (BY WALL PANEL

MANUFACTURER)

HEAD TRIM (BY WALL PANEL

MANUFACTURER)

WINDOW ELEVATION

3/4"=1' 0"A.4

'0

9'

'0

" 20 '0

4'

4'

8'

'0

'0

9'

10'7" 5"

10'7" 5"

10'7" 5"

10'7" 5"

10'7" 5"

10'7"

9'

4'

'0

9'

4'

'0

9'

4'

'8

'0

INT.

CEILING

ENT. CANOPY

INT.

CEILING

CLEAR HT. of CEILING

INT.

CEILING

INT.

CEILING

INT.

CEILING

INT.

CEILING

CLEAR HT. of CEILING

CLEAR HT. of CEILING

TCE (TYP.)

ENT. CANOPY

(METAL PANEL)

E4 BASE TRIM(TYP.)

TCE (TYP.)

CMU, PAINTED (TYP.) CONTROL JOINTS (TYP.)

METAL PANEL

COLOR "B"

METAL PANEL

COLOR "A"

METAL PANEL

COLOR "B"

METAL PANEL

COLOR "A"COLOR "A"

COLOR "A"

COLOR "B"

METALPANEL

COLOR "A"

METAL PANEL

COLOR "B"

METAL PANEL

COLOR "A"

COLOR "B"

COLOR "A"

METAL PANEL

COLOR "A"

METAL PANEL

COLOR "A"

METAL PANEL

COLOR "A"

CMU, PAINTED (TYP.)

CMU, PAINTED (TYP.)

CMU, PAINTED (TYP.) CMU, PAINTED (TYP.)

A.4

ELEVATION‐SOUTH

1/8"=1' 0"

A.4

ELEVATION‐WEST

1/8"=1' 0"

A.4

ELEVATION‐EAST

1/8"=1' 0"

A.4

ELEVATION‐NORTH

1/8"=1' 0"

C AEF D B Aa

CA E FDBAa

1A

A.4

ELEVATION‐WEST

MAIN ENTRANCE CANOPY

1/8"=1' 0"

5'

1 2 3 4 6 7 8 95

1236789 5

* TCE: TRANSITION COVER EXTRUSION WITH REVEAL.

OPEN

OPEN

MEMBRANE FLAHING

EX

TE

R

IO

R E

LE

V A

TI

O N

S

T

YP

W

IN

D

O W

E

LE

V A

TI

O N

E

C O

U N

TY

O

F

SC

H U

Y

LK

IL

L

M

2N D

S

TR

EE

T, P O

TT

SV

IL

LE

, P A

DATE

Drawn By:

Y.

K

IM

A

RC

H

IT

EC

TS

W . M ar ke t St re et

Po tt sv ill e, P

A

T.

.6

.4 yk aa ia gm ai l.c om

T H

E

SC

H U

Y

LK

IL

L

C O

U N

TY

EM

ER

G

EN

CY

S

ER

V

IC

ES

T

RA

IN

IN

G

F A

CI

LI

TY

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

FI

R

EM

EN

'S R

O A

D , F

R A

CK

V

IL

LE

, P A yK yK2

A.

EMAFS

6"

1/ 2"

8"

8"

8"

8" 1 1/2"

1/2"

6"

1/ 2"

6"

4"

10"

4"

5 1/2"

4 1/2" 3 1/2"

6"

1/ 2"

8"

1/

2"

6"

4"

5 1/2"

6"

5 1/2"

8"

8"

4"

A

B

E3 E2

E1

F

L

M

K

G

B

H

M

A

B

E3 E2

E1

L

M

K

B

K

K

F

E

G HGH

K

HSS

M

M

K

M

K

HSS

HSS

K B

B & E

HSS

B & E

K

K

M1

K1

B & E

HSS

K.1

B & E

K.1

H

F

M 2

M 2

GYP. BD.

2‐1/2" STUD

GYP. BD.

2‐1/2" STUD

HSS

GYP. BD.

6" STUD

GYP. BD.

2‐1/2" STUD

HSS

K

M1

K1 E

M2

M2

F

A

4"

1‐ 1/

2"

2‐ 3/

4"

1‐1/8"

A: WINDOW

B: BACKER ROD & SEALANT

C: ANGLE TRIM w/ RETURN

D: ANGLE TRIM w/ BUTYL TAPE

E: 'J' CHANNEL

E1: JAMB COVER (EXTRUSION)

G: AIR & WATER BARRIER. "TREMCO

EXO AIR 230 SYSTEM" AT ALL

EXTERIOR WALLS.

H: EXT. METAL PANEL

M: METAL STUDS (6")

w/ INSULATION (R=23)

K: GYPSUM WALLBOARD

L: INTERIOR WOOD TRIMS

C1: SILL TRIM w/ RETURN

D2: HEAD ANGLE TRIM w/RETURN

D1: HEAD TRIM

J: COPING SYSTEM

N: WOOD BLOCKING

P: HOLLOW METAL DOOR FRAME

P1: MC 6 x 15.1 (PAINTED)

E2: RECEIVER EXTRUSION FOR

JAMB COVER

E3: ANGLE TRIM

K1: METAL LINER PANELS

F: PLYWOOD (1/2")

F1: FLUSH TRANSITION COVER

EXTRUSION

M1: MASONRY

M2: RIGID INSULATION (R‐16)

P2: L 3 x 3 x 1/2 (PAINTED)

Z: SUPPORT "Z"

F2: RECEIVER EXTRUSION FOR "F1"

T: O.H. DOOR TRACK

T1: O. H. DOOR

A

4"

1‐ 1/

2"

2‐ 3/

4"

1‐1/8"

A‐5A‐1

F‐1 (OPP.)

F‐5

A‐9A‐8

F‐8 (OPP.) F‐9 (OPP.)

C‐9 C'‐9B‐9 D‐9 E‐9

EB

DC

B‐2

E‐2

C‐2

D‐2

F‐8

A.5.1

1 COLUMN PLAN DETAILS

1‐1/2"=1' 0"

5.1

EX

TE

R

IO

R W

A

LL

S

EC

TI

O

N S

E

C O

U N

TY

O

F

SC

H U

Y

LK

IL

L

M

2N D

S

TR

EE

T, P O

TT

SV

IL

LE

, P A

DATE

Drawn By:

Y.

K

IM

A

RC

H

IT

EC

TS

W . M ar ke t St re et

Po tt sv ill e, P

A

T.

.6

.4 yk aa ia gm ai l.c om

T H

E

SC

H U

Y

LK

IL

L

C O

U N

TY

EM

ER

G

EN

CY

S

ER

V

IC

ES

T

RA

IN

IN

G

F A

CI

LI

TY

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

FI

R

EM

EN

'S R

O A

D , F

R A

CK

V

IL

LE

, P A yK yK2

A.

EMAFS

6" 2" 4"

4"

1/

2"

2'

8"

8"

5"

6"

4"

8"

4 1/2" 3 1/2"

4 1/2" 3 1/2"

8"

1'0"

8"

4"

3 1/2" 4 1/2"

4 1/2"

1'

0"

1'

0"

1'

0"

K

M

PMF

FINISH GRADE

MS

E4

H

K1

M

MS

SC

H

BASE TRIM

(MITERED

@ CORNERS

PMF

CMU,

PAINTED

2" RIGID INSULATION

HORIZ. REINF.

@ 16" O.C.

K1

M

E4

H

F G

N

J

Z

H

F

G

E

RM

M

F

R‐INSUL

TYP. PARAPET

DETAIL (12" VERT. MIN.)

TYP. ROOF DETAIL #4

R‐INSUL

J J

K1

M

W16 x 31

PMF

HORIZ. REINF.

@ 16" O.C.

J

K1

SEALANT

STANDARD METAL

TERMINATION

BASE TRIM

METAL PANEL

R‐INSUL

K1

M

MEMBRANE FLASHING

TYP.

ROOF DETAIL #3

ROOFING

MEMBRANE

PLYWOOD WITH

EXOAIR 230 SYSTEM

W18 x 35

PMF

CONC. FOOTING

CONC. FOOTING

W16 x 31

Z

H

F

G

E

CRUSHED

STONE (8")

FINISH GRADECONC. SLAB ON

VAPOR BARRIER &

2" RIGID INSULATION

CONC. SLAB

M

M

M

PERIMETER

INSUL (2")

CRUSHED

STONE

CONCRETE SLAB ON

10 MIL VAPOR BARRIER

(TYP.)

CRUSHED

STONE

(6"‐TYP.)

CONCRETE SLAB ON

10 MIL VAPOR

BARRIER (TYP.)

PERIMETER

INSUL (2")

PLYWOOD WITH

EXOAIR 230 SYSTEM

M

W18 x 31

CMU,

PAINTED

CMU,

PAINTED

CMU,

PAINTED

GYPSUM WALLBOARD

ON 2‐1/2" METAL STUDS

1‐1/8"

7/ 8"

1‐ 3/

4"

1‐3/8"

2"

3"

1‐1/4"

1‐ 1/

4"

3/4"

4"

4"

OF COLUMN

EBT

MS

A.5.2

2 WALL SECTION

1‐1/2"=1' 0"

A.5.2

4 WALL SECTION

1‐1/2"=1' 0"

A: WINDOW

B: BACKER ROD & SEALANT

C: ANGLE TRIM w/ RETURN

D: ANGLE TRIM w/ BUTYL TAPE

E: 'J' CHANNEL

E1: JAMB COVER (EXTRUSION)

G: AIR & WATER BARRIER (TYP.)

M: METAL STUDS (6")

w/ INSULATION (R=23)

K: GYPSUM WALLBOARD (5/8")

L: INTERIOR WOOD TRIMS

C1: SILL TRIM w/ RETURN

D2: HEAD ANGLE TRIM w/RETURN

D1: HEAD TRIM

J: COPING SYSTEM

N: WOOD BLOCKING

P: HOLLOW METAL DOOR FRAME

P1: MC 6 x 15.1 (PAINTED)

E2: RECEIVER EXTRUSION FOR

JAMB COVER

E3: ANGLE TRIM

K1: METAL LINER PANELS. "ATAS"

"DESIGN WALLS‐DWH120" 1‐1/8"

F: PLYWOOD (1/2")

F1: FLUSH TRANSITION COVER

EXTRUSION

M1: MASONRY

M2: RIGID INSULATION (R‐16)

P2: L 3 x 3 x 1/2 (PAINTED)

Z: SUPPORT "Z"

F2: RECEIVER EXTRUSION FOR "F1"

T: O.H. DOOR TRACK

T1: O. H. DOOR

LEGEND

RM: ROOFING MEMBRANE (TYP.)

R‐INSUL: ROOF INSULATION

A.5.2

1 WALL SECTION (TYP.)

1‐1/2"=1' 0"

SLOPED TO DRAIN

(1/4" PER FOOT)

1‐1/8"

7/ 8"

1‐ 3/

4"

A.5.2

3 WALL SECTION

1‐1/2"=1' 0"

OF COLUMN

1/2"

1/ 2"

1‐1/4"

3"92E4

E

H: EXT. METAL PANEL SHALL

BE "ATAS" "RIGIDWALL

MFN 160" (ALUMINUM

0.050") ON EXOAIR 230 SYSTEM.

E

* FOR CONTINUATION,

SEE STRUCTURAL DRAWINGS

* FOR CONTINUATION,

SEE STRUCTURAL DRAWINGS * FOR CONTINUATION,

SEE STRUCTURAL DRAWINGS

4'

4'

FLOOR FLOOR

WALL WALL

FIRE EXTINGUISHER DETAILS

PL

AN

S

EL

EV

AT

IO

N

S

FIRE EXTINGUISHER

W/ CABINET

FIRE EXTINGUISHER

W/O CABINET

5.2

C O

LU

M

N D

ET

A

IL

S

D O

O R J

A M

B

E

C O

U N

TY

O

F

SC

H U

Y

LK

IL

L

M

2N D

S

TR

EE

T, P O

TT

SV

IL

LE

, P A

DATE

Drawn By:

Y.

K

IM

A

RC

H

IT

EC

TS

W . M ar ke t St re et

Po tt sv ill e, P

A

T.

.6

.4 yk aa ia gm ai l.c om

T H

E

SC

H U

Y

LK

IL

L

C O

U N

TY

EM

ER

G

EN

CY

S

ER

V

IC

ES

T

RA

IN

IN

G

F A

CI

LI

TY

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

FI

R

EM

EN

'S R

O A

D , F

R A

CK

V

IL

LE

, P A yK yK2

A.

EMAFS

5"

6"

3 1/2" 4 1/2"

8"

8"

8"

1'0"

A

B

C1

E

Z

F K

M

L

N

A

K M

L

N

B A

B

D2

D1

Z

H

G

H

F G

P B

D2

D1

Z

F G

H

K M

N

F

M

N

J

Z

H

F

G

E

A B

E3 E2

E1F

H

L

M

K

G

B

AF

H

L

M

K

G

B

B

E3 E2

E1

K1

M

N

P B

H G

F

E2

E3 E1

F

H

M

K1

G E3

F1

F2

E3

K1

M

N

P B

H G

F

E2

E3 E1

P2 B

D2

D1

Z

F G

H

K1 M

M2

E

P1

M

M2

K1

P2

B

H

G

F

E2

E3 E1

B

M1

M1

M2

T

P1

P2

P1

M2

T

T1 T1

K

M

PMF

FINISH GRADE

MS

E4

H

PERIMETER

INSULATION

CRUSHED

STONE

CONC. SLAB ON

VAPOR BARRIER

DOOR HEAD

PA

RA

PE

T

WINDOW JAMB @ FIXED WINDOW JAMB @ VENT

W

IN

D O

W H

EA

D

M

ID

‐P O

IN

T

W

IN

D O

W S

IL

L

TRANSITION COVER DETAIL

5 DOOR JAMB

1‐1/2"=1' 0"

4 DOOR JAMB

1‐1/2"=1' 0"

A.5.3

1‐1/2"=1' 0"

O.H.DOOR HEAD

A.5.3

1 PLAN DETAIL

1‐1/2"=1' 0"

3/4"

1"

1"

1/2"

4‐1/4"

2" 1/

2"

1/ 2"

1‐1/4"

3" 92 D1

Z

A: WINDOW

B: BACKER ROD & SEALANT

C: ANGLE TRIM w/ RETURN

D: ANGLE TRIM w/ BUTYL TAPE

E: 'J' CHANNEL

E1: JAMB COVER (EXTRUSION)

H: EXT. METAL PANEL

M: METAL STUDS (6")

w/ INSULATION (R=23)

K: GYPSUM WALLBOARD

L: INTERIOR WOOD TRIMS

C1: SILL TRIM w/ RETURN

D2: HEAD ANGLE TRIM w/RETURN

D1: HEAD TRIM

J: COPING SYSTEM

N: WOOD BLOCKING

P: HOLLOW METAL DOOR FRAME

D2

3‐ 1/

2"

1/2"

3"

1"

1‐5/8"

7/8"

1‐3/4"

1‐ 1/

8"

C

D

E

3‐3/4" 1/2"

2"

1"

1/ 2"

C1

P1: MC 6 x 15.1 (PAINTED)

TRIM SCHEDULE

2"

3" E1

E22"

7/16"

E2: RECEIVER EXTRUSION FOR

JAMB COVER

E3: ANGLE TRIM

E3 1‐5/8"

1"

5" F1

F2 2‐1/2"

7/ 8"

K1: METAL LINER PANELS

F: PLYWOOD (1/2")

F1: FLUSH TRANSITION COVER

EXTRUSION

M1: MASONRY

M2: RIGID INSULATION (R‐16)

P2: L 3 x 3 x 1/2 (PAINTED)

Z: SUPPORT "Z"

F2: RECEIVER EXTRUSION FOR "F1"

T: O.H. DOOR TRACK

T1: O. H. DOOR

O.H.DOOR JAMB @ METAL WALLO.H.DOOR JAMB @ MASONRY WALL G: AIR & WATER BARRIER. "TREMCO

EXO AIR 230 SYSTEM" AT ALL

EXTERIOR WALLS.

1‐1/2"=1' 0"

A.5.3

RM: ROOFING MEMBRANE (TYP.)

R‐INSUL: ROOF INSULATION

A.5.3

1‐1/2"=1' 0"

1‐1/2"=1' 0"

E4: BASE TRIM‐11/2"

1/ 2"

1‐1/4"

3" 92 E4

A.5.3

9 TYP. WINDOW DETAILS

1‐1/2"=1' 0"

1/2"

1/ 2"

1‐1/4"

3" 92 E4

A.5.3

A.5.3A.5.3

A.5.3

1‐1/2"=1' 0"

A.5.3

1‐1/2"=1' 0" A.5.3 8A

1‐1/2"=1' 0"

PLAN DETAIL

* FOR CONTINUATION,

SEE STRUCTURAL DRAWINGS

5.3

TY

P.

E X

TE

R

IO

R W

A

LL

S

EC

TI

O

N

TY

P.

W

IN

D O

W D

ET

A

IL

S

O .H

D

O O

R T

R A C K

D

ET

AI

LS

E

C O

U N

TY

O

F

SC

H U

Y

LK

IL

L

M

2N D

S

TR

EE

T, P O

TT

SV

IL

LE

, P A

DATE

Drawn By:

Y.

K

IM

A

RC

H

IT

EC

TS

W . M ar ke t St re et

Po tt sv ill e, P

A

T.

.6

.4 yk aa ia gm ai l.c om

T H

E

SC

H U

Y

LK

IL

L

C O

U N

TY

EM

ER

G

EN

CY

S

ER

V

IC

ES

T

RA

IN

IN

G

F A

CI

LI

TY

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

FI

R

EM

EN

'S R

O A

D , F

R A

CK

V

IL

LE

, P A yK yK2

A.

EMAFS

8"

8"

2'

'9

JAMB BRACKETS

BREAKAWAY TRACK

ASSEMBLY

HORIZONTAL

TRACK

ASSEMBLY

HORIZONTAL

TRACK

SUPPORT

VERTICAL TRACK

ASSEMBLY (2")

F

M N

J

Z

H

F G

E

M1

(BEYOND)

SEE

STRUCTURAL

DRAWING

PMF

M W18 x 35

P2 B

Z F

H

P1

D2

D1 G

M

A.5.4

1 WALL SECTION @ O.H. DOOR

1‐1/2"=1' 0"

FIN @ H.P.

[O . H

. D O

O R

H

EI

G H

T]

1'

8"

3'

9'

4'

1'4"

5'

TYP. PARAPET DETAIL J

"WIND‐LOK"

SOFFIT

STEEL

ROOF DECK

ROOF

INSULATION

METAL STUD

SUBFRAME

STEEL

BEAM

TYP. REINF.

CONCRETE

FOOTING

HSS COLUMN

E4

SLOPED TO DRAIN

(1/4" PER FOOT)

CARPORT DETAIL

3/4"=1' 0"

A.5.4

2'6"

4'

3'

2'

9'

2'

8"

1'

5'0"

2'6"

F

M

N

J

Z

H

F

G

E

E4

SPLIT FACE

CMU @ ALL

4 SIDES

SMOOTH FACE

CMU @ ALL

4 SIDES

"WIND‐LOK" SOFFIT BY "ATAS",

.032 ALUM. STUCCO EMBOSSED

OR APPROVED EQUIVALENT BY OWNER.

SUBFRAME:GALV. METAL FRAME 6" X 15 GA.

J

Z

H

F

G

E

W16 x 31

H

F

F

M

N

HSS 6

4" CMU, W/ HORIZ.

REINF.@ 24" O.C.

6" CMU, TIED

TO HSS,

@ 24: O.C.

4" CMU, W/ HORIZ.

REINF.@ 24" O.C.

W16 x 31

M

EPDM ROOFING MEMBRANE

TAPERED ROOF INSULATION

ROOF INSULATION

ROOF DECK (TPY.)

M

HSS 6

TOP PLATE (1 X 1 X 1/2)

SEALANT

STANDARD METAL

TERMINATION

BASE TRIM

METAL PANEL

MEMBRANE FLASHING

TYP.

ROOF DETAIL #3

ROOFING

MEMBRANE

TYP. EXTERIOR WALL

ASSEMBLY

HSS 6, SEE

STRUCTURAL DRAWINGS

REINF. CONCRETE PIER

(18" x 18")

4" CMU, W/ HORIZ. REINF.

@ 24" O.C.

FINISH GRADE

SPLIT FACE CMU

TYP. EXTERIOR

COLUMN FOOTING.

SEE STRUCTURAL DETAILS

M

CMU (4")

REINF. CONCRETE PIER

(18" x 18")

FIN. FLOOR

CAVITY

1‐1/8"

7/ 8"

1‐ 3/

4"

E

A

OF COLUMN

Aa

OF COLUMN

A.5.4

2 CANOPY COLUMN ELEVATION DETAIL (TYP.)

1"=1' 0"

A.5.4

3 WALL SECTION (TYP.)

1"=1' 0"A.5.4

1 CANOPY COLUMN PLAN DETAIL (TYP.)

1"=1' 0"

NOTE:

IN ADDITION TO HORIZONTAL TIES, THE CMU SHALL BE TIED

TO HSS WITH "HB‐213 ADJUSTABLE VENEER ANCHOR".

5/28/25

5.4

GA

RA

GE

W

AL

L

SE

CT

IO

N, FR

ON

T

CA

NO

PY

D

ET

AI

L

CA

RP

OR

T

DE

TA

IL

E

C O

U N

TY

O

F

SC

H U

Y

LK

IL

L

M

2N D

S

TR

EE

T, P O

TT

SV

IL

LE

, P A

DATE

Drawn By:

Y.

K

IM

A

RC

H

IT

EC

TS

W . M ar ke t St re et

Po tt sv ill e, P

A

T.

.6

.4 yk aa ia gm ai l.c om

T H

E

SC

H U

Y

LK

IL

L

C O

U N

TY

EM

ER

G

EN

CY

S

ER

V

IC

ES

T

RA

IN

IN

G

F A

CI

LI

TY

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

FI

R

EM

EN

'S R

O A

D , F

R A

CK

V

IL

LE

, P A yK yK2

A.

EMAFS

6"

8"

6"

1/ 2"

8"

1/

2"

MIDRAIL

BOTTOMRAIL

GLASS

(TYP.)

GLASS

(TYP.)

GLASS

(TYP.)

ALUMINUM

THRESHOLD

(ADA COMPLIANT)

M

SENSOR

B

TOPRAIL

SENSOR

E1

E2 E3

B A

B

E3 E2

E1

F

L

M

K

G

B

H

M

A

B

E3

E2 E1

L

M

K

B

K

SLIDING DOOR SECTION (TYP.)

11/2"=1' 0"A.6.1

3'

7'

5'0"

10'0"

PLAN (AUTO. ENTRANCE DOOR)

11/2"=1' 0"A.6.1

A

11/2"=1' 0"A.6.1

3PLAN DETAIL (VESTIBULE.)

11/2"=1' 0"A.6.1

2 PLAN DETAIL (VESTIBULE.)

10'0"

11'5"

'6

'0

9'

7'

9'

7'

" 9'

6'

0"

4" 3'

2" 2'

0"

6"

CEILING

CEILING CEILING

VESTIBULE

/100

A

A.6.1

A.6.1

A.6.1

A.6.1

PLAN‐VESTIBULE

ELEV. #2‐DOOR/100A

ELEV. #1‐DOOR/100

ELEV. #3‐GLASS WALL

ELEV. #1

1/4"=1' 0" 1/4"=1' 0"

1/4"=1' 0" 1/4"=1' 0"

ELEV. #3

EL

EV

* Framing: Kawneer Trifab 451 (4" x 2") Dark Bronze Annodized Finish

* Glazing: Tempered Clear Glass (1/4")

* Framing: Kawneer Trifab 451 (4" x 2") Dark Bronze Annodized Finish

* Glazing: Tempered Clear Glass (1/4")

* Framing: Kawneer Trifab 451 (4" x 2") Dark Bronze Annodized Finish

* Glazing: Tempered Clear Glass (1/4")

* Framing: Kawneer Trifab 451 (4" x 2") Dark Bronze Annodized Finish

* Glazing: Tempered Clear Glass (1/4")

4" X

8"

X

/4

W

IR

ED

G

LA

SS

W

IN

D O

W

M

IN

" X

8"

X

/4

W

IR

ED

G

LA

SS

W

IN

D O

W

TYPE "F"

D O

O R

TY

PE

S

TYPE "W"TYPE "A" TYPE "WL"

"Fine Fissured #680, White w/ "Prelude" Suspension System.

KEY MAKE

V Vinyl Base Johnsonite

VP Vinyl Plank

ATC

ATC*

DESCRIPTION

Vinyl Cove Base 4"H

"Luxury Vinyl Plank" 0.20" Thick (6" or 8" x 48")

"Cortega White 2 x 4"Acoustical Ceiling Armstrong

Acoustical Ceiling Moisture Resistant Armstrong

CFT Ceramic Floor Tile Daltile "Keystone Unglazed" 2" x 2"

CWT Ceramic Wall Tile Daltile

Armstrong

"Luxury Vinyl Plank" 0.20" Thick (6" or 8" x 48")Shaw Ind.

P Paint Semi‐Gloss Latex, unless otherwise noted

FM Floor Mat Mondo Zeus "3.5 mm, Hammered Texture 39‐3/8" x 39‐3/8" "

Ceramic Tile Base Daltile Ceramic Cove Base, Matte Group 1 (41/4 x 41/4)CT

Ceramic Wall Tile, Matte Group 1 (41/4 x 41/4)

ROOM

NO. ROOM

LOBBY

FLOOR BASE WALL CEILING REMARKS

INTERIOR FINISH SCHEDULE

VESTIBULE100 P

HALL

VP V

V

HT

FM

103 OPERATION

104 HALL

105 RECEPTION 8'6"

106 IT ROOM

107 OFFICE

108 8'6"

114 BREAK ROOM

115 CORRIDOR 9'

116 9'

117 CT CWT‐PLADIES' 9'CFT

118 VJANITOR'S 9'CONC

119 CTMEN'S 9'CFT

200 VCORRIDOR VP

204 TRAINING

205 ACTSTORAGE CONC

206 CT CWT‐PMEN'S CFT

207 V P ACTVENDING VP

208 CTLADIES' CFT

209 V ACTSTORAGE CONC

210 ACT

ELECTRICAL

211 EC

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORRIDOR

CORRIDOR

TRAINING

TRAINING

STORAGE

300 ECGARAGE ‐

9'

9'

9'

9'

9'

9'

9'

9'

9'

9'

9'

9'

9'

9'

9'

9'

DOOR

NO. MATERIAL SIZE REMARKS

DOOR SCHEDULE

FRAME

AL100

TYPE

A AL ‐

FRAME

AL100A A

WD105 F HM 3' 0" X 6' 8"

WD106 F HM 3' 0" X 6' 8"

WD107 F HM 3' 0" X 6' 8"

WD108 F HM 3' 0" X 6' 8"

WD109 F HM 3' 0" X 6' 8"

WD110 F HM 3' 0" X 6' 8"

WD111 F HM 3' 0" X 6' 8"

WD112 F HM 3' 0" X 6' 8"

WD113 F HM 3' 0" X 6' 8"

WD114 F HM 3' 0" X 6' 8"

WD115 W HM 3' 0" X 6' 8"

HM‐I115A W HM 3' 0" X 6' 8"

WD117 F HM 3' 0" X 6' 8"

WD118 F HM 3' 0" X 6' 8"

WD119 F HM 3' 0" X 6' 8"

HM‐I201 F HM (2) 3' 0" X 6' 8"

WD202 F HM

WD203 F HM

WD204 F HM

HM205 F HM (2) 3' 0" X 6' 8"

WD206 F HM 3' 0" X 6' 8"

WD207 F HM 3' 0" X 6' 8"

WD208 F HM 3' 0" X 6' 8"

WD209 F HM

HM210 F HM

HM210A F HM

HM211 F HM 3' 6" X 6' 8"

HM212 F HM

HM300 W HM

F HM 3' 0" X 6' 8"

F HM 3' 0" X 6' 8"

F HM 3' 0" X 6' 8"

F HM 3' 0" X 6' 8"

STL HM 12' 0" X 14' 9"

HM

HM

Wa HM

(2) 3' 0" X 6' 8"

(2) 3' 0" X 6' 8"

(2) 3' 0" X 6' 8"

(2) 3' 0" X 6' 8"

(2) 3' 0" X 6' 8"

3' 0" X 6' 8"

300A

300B

300C

300D

300E

300F

300G

300H

Wa

Wa

Wa

HM‐I

AL. Threshold: Aluminum Threshold.

SC‐WD: Solid Core Wood Door with Plastic Laminate Finish

AL

WD200 W HM (2) 3' 0" X 6' 8"

AL. Threshold: Aluminum Threshold.

HM: Hollow Metal.

HM‐I: Hollow Metal‐Insulated.

Wa: With Windows

P

VP

VP

VP

VP

VP

VP

VP

VP

VP

VP

VP

VP

VP

VP

VP

V

V

V

V

V

V

V

V

V

V

V

V

V

V

V

VP

VP

VP

VP

V

V

V

V

V

P

VCONC

VCONCMECHANICAL

VCONC P

VCONC CMU+ML

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

101 WD W HM 3' 0" X 6' 8"

ACT*

GYP "Moisture Resistant Wall Board"GYpsum Board

ACT*

ACT*

EC

ACT

ACT

ACT

ACT

ACT

ACT*

ACT*

ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT

CWT‐P

CWT‐P

CWTP Ceramic Wall Tile+P Daltile+P Ceramic Wall Tile, Matte Group 1 (5 FT High) + P

9'

8'6"

8'6"

8'6"

8'6"

8'6"

8'6"

8'6"

NOTES:

1. All GYPSUM WALLBOARD at WALLS & CEILINGS AT "WET" SPACES, i.e.

REST ROOMS shall be MOISTURE RESISTANT‐TYPE.

2. INSTALL METAL TRANSITION STRIPS BETWEEN DIFFERENT FLOORING

MATERIALS (MOSTLY UNDER THE DOORS).

3. INSTALL WATERPROOFING MEMBRANE ["SCHLUTER KERDI" 8 MIL], ON CONCRETE FLOOR,

BEFORE FINAL FLOOR FINISH at #117, #119, #206 & #208.

4. INSTALL CONCRETE SEALER/HARDENER, "SIKA GUARD 200 HDWB" at #205, #209, #210, # 211, #212, & #300.

Metal Liner shall be "Design Wall DSF 120 (.032" ALUM by ATAS".

CMU+ML CMU,Painted +Metal Liner

STL

STL

STL

(2) 3' 0" X 6' 8"

HM‐I

HM‐I

HM‐I

(2) 3' 0" X 6' 8"

F HM 3' 0" X 6' 8"

F HM 3' 0" X 6' 8"

F HM 3' 0" X 6' 8"

202A

203A

204A

HM‐I

HM‐I

HM‐I

12' 0" X 14' 9"

12' 0" X 14' 9"

12' 0" X 14' 9"

6.1

IN

TE

RI

OR

F

IN

IS

H

SC

HE

DU

LE

DO

OR

S

CH

ED

UL

E, M

AI

N

EN

TR

AN

CE

D

OO

R

EL

EV

AT

IO

NS

AU

TO

M

AT

IC

D

OO

R

DE

TA

IL

E

C O

U N

TY

O

F

SC

H U

Y

LK

IL

L

M

2N D

S

TR

EE

T, P O

TT

SV

IL

LE

, P A

DATE

Drawn By:

Y.

K

IM

A

RC

H

IT

EC

TS

W . M ar ke t St re et

Po tt sv ill e, P

A

T.

.6

.4 yk aa ia gm ai l.c om

T H

E

SC

H U

Y

LK

IL

L

C O

U N

TY

EM

ER

G

EN

CY

S

ER

V

IC

ES

T

RA

IN

IN

G

F A

CI

LI

TY

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

FI

R

EM

EN

'S R

O A

D , F

R A

CK

V

IL

LE

, P A yK yK2

A.

EMAFS

5'

2'

4'6"

2'6" 2'6" 2'8"

9'

6'

0"

2'

0"

3'

2'

2'6" 2'7" 1'3"

2'7" 2'6" 1'3"

2'

0"5'

" 6'

0"

2'

0"

3'

2'

2'6"2'7" 3'7"

2'7" 2'6" 1'3"

2'

0"5'

8'

/2

1'

4'

0"

1'

1'

2'5" 2'10" 3'10"

1'

5'

1"

9'

2'

2'

0" 3'

2'

6'

0"

2'

0"

2'

3'

2'

MIRROR(TYP.)

MIRROR(TYP.)

HAND

DRYER:

HAND

DRYER:

ROLLIN

SHOWERSHOWER

ROLLIN

SHOWER SHOWER

MIRROR(TYP.)

MIRROR(TYP.)

HAND

DRYER:

HAND

DRYER

HAND

DRYER

(TYP.)

HAND

DRYER

(TYP.)

HAND

DRYER

(TYP.)

HAND

DRYER

(TYP.)

TOWEL

BAR

(TYP.)

TOWEL

BAR

(TYP.)

TB

(TYP.)

MEN'S

/206

JAN.

/118

LADIES'

/208

VENDING

/207208

LADIES'

/117

MEN'S

/119

EW

C

#2

#1

#3

#2

#1

#3

#2

#1

#3

#2

#1

#3

#4

#2

#1

#4

#3

#2

#1

#3

#1

#3

#1

#2

#2

#3

OPEN

SINK

BASE

#1

LADIES'/117 & MEN'S/119

LADIES'/208 MEN'S/206

#1

OPEN

SINK

BASE

#1

1 Mirror 780‐18300 40" TO BOTTOM Four (4)

2 Toilet Tissue Holder 5084 19" TO CENTER LINE Ten (10)

001/2 +003 36" TO TOPGrab Bars (36" + 54" + 12"(V))

2902‐2874 48" TO TOPHand Dryer

931 72" TO TOPRobe Hook Eight (8)

Thermostat

Light Switch 48" TO TOP

48" TO TOP

48" TO TOP of BRAILLESigns

NOTE: THE CONTRATOR SHALL BE RESPONSIBLE FOR STURCTURAL SUPPORTS FOR THE

ACCESSORIES AND PROVIDE STRUCTURAL SUPPORTS OF MINIMUM 250 LBS APPLIED AT

ANY POINT OF THE ACCESSORIES, FASTENERS, MOUNTING DEVICES AND SUPPORTING

STRUCTURE. THE SUPPORTING STRUCTURE SHALL BE PRESSURE TREATED LUMBER

(2" X 6" X ) BEHIND SPECIFIED FINISH MATERIALS.

TOILET ACCESSORIES ["BRADLEY" MODEL NUMBERS unless otherwise noted]

& TYPICAL MOUNTING HEIGHTS

ITEM MODEL NO. MOUNTING HEIGHT

ABOVE FIN. FL.

FURNISH &

INTALL FOR

THIS PROJECT

Four (4)

Four (4)

6 9054‐24 36" TO TOPTowel Bar Eight (8)

1'0" 3'0"

3'

2'

0" 3'

8'

1/

2"

3'

1'

4'6"

3'4"

1'0" 3'6"

3'

2'0"

3'6"

1'

4'

16" ~ 18"

GRAB BAR

PROTRUDING DISPENSER

BELOW GRAB BAR

TYPICAL ELEVATIONS REST ROOM

MIRROR

(m in

(m in

(max) (min)

(min)

(max)

(min)

3"

2'

0"

1/

2"

1'0"

2'

2'

0"

1/

2"

1'0"

2'

4" 2'

1'0" 1'0"

2'1"

2'1"

#3 #2

#5

#6

#7

#4

#1

#8

#7 #6

#5

#1

#5

#7

#3 #2

#7

#9

#7 #6

#5

#1

#5

#7

#4

3/4"=1' 0"

TYPICAL CABINET DETAILS

PLYWOOD DRAWER BOTTOM, 3/4"

KEY

#5

HARDWOOD WEB FRAME, 3/4" X 2‐1/2"#7

#1

BACKSPLASH, 3/4" X 4"

#6 3/4" PLYWOOD SHELF WITH EDGE BANDS

#8 2 X 4 WOOD STRECHERS @ 2' O.C.

3/4" PLYWOOD DOOR WITH EDGE

BANDS, FINISHED FRONT & BACK

#2 3/4" PLYWOOD COUNTER TOP

(PLASTIC LAMINATE FINISH)

#3

RECESSED SHELF STANDARDS

FINISH: UNLESS OTHERWISE NOTED,

THE EXTERIOR FINISH SHALL BE

HIGH PRESSURE PLASTIC LAMINATE

V A

RI

ES

(S

EE

E

LE

V A

TI

O

N S)

A.6.2

3/4"=1' 0"

TYPICAL SINK TOP DETAILS

V A

RI

ES

(S

EE

E

LE

V A

TI

O

N S)

A.6.2

#9 PLYWOOD, 3/4", FINISHED BOTH SIDES

& EDGES

6.2

R

ES

TR

O

O M

E N

LA

R G

ED

PL

A N

S

EL

EV

A

TI

O N

S, TO

IL

ET

A C C

ES

S O

R

IE

S

C A B

IN

ET

D

ET

A

IL

E

C O

U N

TY

O

F

SC

H U

Y

LK

IL

L

M

2N D

S

TR

EE

T, P O

TT

SV

IL

LE

, P A

DATE

Drawn By:

Y.

K

IM

A

RC

H

IT

EC

TS

W . M ar ke t St re et

Po tt sv ill e, P

A

T.

.6

.4 yk aa ia gm ai l.c om

T H

E

SC

H U

Y

LK

IL

L

C O

U N

TY

EM

ER

G

EN

CY

S

ER

V

IC

ES

T

RA

IN

IN

G

F A

CI

LI

TY

Approved By:

Checked By:

DATE

CONTRACTOR SHALL BE

RESPONSIBLE FOR

VERIFICATION OF ALL

DIMENSIONS & EXISTING

CONDITIONS THAT WILL

AFFECT NEW WORK.

FI

R

EM

EN

'S R

O A

D , F

R A

CK

V

IL

LE

, P A yK yK2

A.

EMAFS

8"

GYP. BD. (1/2")

EDGE SEALANT (1/8" BEAD)

MIN. 1"

MAX. 12"

FILLER

EDGE SEALANT (TYP.)

FASTENER &

FASTENING

PLATE

@ 12" OC

PENETRATION

MIN 11/2" HOT AIR WELD

ROOFING MEMBRANE

NONSAG

POLYURETHANE

SEALANT

M

IN

2"

MIN. 1"

FASTENING PLATE @ 12" OC

INSEAM SEALANT

SPLICING CEMENT

LAP SEALANT

ROOFING MEMBRANE

BONDING ADHESIVE

MEMBRANE FLASHING

METAL FLASHING

ROOF CURB

ROOF DRAIN

CLAMPING RING

ROOFING

MEMBRANE

WATER CUTOFF

MASTIC

INSULATION

ROOF CURB

INSULATION

ON AIR/VAPOR BARRIER

INSULATION

ON AIR/VAPOR BARRIER

FASTENING PLATE @ 12" OC

INSEAM SEALANT

SPLICING CEMENT

LAP SEALANT

ROOFING

MEMBRANE

MEMBRANE FLASHING

ALUM. COVER (.050") W/ CLEATS

NEW TREATED 2 X 6

WATER

CUTOFF

MASTIC

MIN. 6" WIDE

PRESSURESENSITIVE

ELEASTOFORM FLASHING

IN CONJUNCTION WITH

MEMBRANE PRIMER

WATER

CUTOFF

MASTIC

MEMBRANE

BONDING

ADHESIVE

ROOFING

MEMBRANE

SEALANT

TRETAED

LUMBER NAILER

COPPER

(20 OZ.)

SCUPPER

TO

B

E

IN

C O

N

FO

R M

AN

C

E W

IT

H

L

AT

ES

T"

SM

AC

N A"

D

ET

AI

LS

INSULATION

ON AIR/VAPOR

BARRIER

IN‐SEAM SEALANT

SPLICING CEMENT

BONDING ADHESIVE

MEMBRANE FLASHING

SEALANT

ROOFING

MEMBRANE

LAP SEALANT

FASTENING

PLATE @ 12" OC

INSULATION

ON AIR/VAPOR BARRIER

IN‐SEAM SEALANT

SPLICING CEMENT

BONDING ADHESIVE

MEMBRANE FLASHING

STANDARD METAL

TERMINATION

BASE TRIM

'E4'

ROOFING

MEMBRANE

LAP SEALANT

FASTENING

PLATE @ 12" OC

INSULATION

ON AIR/VAPOR BARRIER

METAL PANEL

IN‐SEAM SEALANT

SPLICING CEMENT

BONDING ADHESIVE

MEMBRANE FLASHING

SEALANT

ROOFING

MEMBRANE

LAP SEALANT

FASTENING

PLATE @ 12" OC

INSULATION

ON AIR/VAPOR BARRIER

IN‐SEAM SEALANT

SPLICING CEMENT

BONDING ADHESIVE

MEMBRANE FLASHING

STANDARD METAL

TERMINATION

ROOFING

MEMBRANE

LAP SEALANT

FASTENING

PLATE @ 12" OC

INSULATION

ON AIR/VAPOR BARRIER

ROOFING

MEMBRANE

PIPE

WATER CUT‐OFF MASTIC

ST.STL. CLAMPING RING

PREMOLDED PIPE SEAL

LAP SEALANT

INSULATION

ON AIR/VAPOR BARRIER

EX

TE

RI

O

R W

A

LL

EX

TE

RI

O

R W

A

LL

ROOF DETAILS

3"=1' 0"A.6.4

SEALANT POCKET TYPICAL CURB DETAIL

TEMINATION DETAIL @ HIDDEN AREA

ROOF DRAIN DETAIL#5

#1

#6

#2

#7

#3HVAC UNIT BASE DETAIL (ONE OF PAIR)

[8 x 8"

O

PE

N

IN

G

OVERFLOW SCUPPER DETAIL

1‐1/4"

3"

1/2"

PIPE & CIRCULAR PENETRATION DETAIL#8

TEMINATION DETAIL @ HIDDEN AREA#4

6.3

R O

O F

D

ET

A

IL

1 EMA CS
EMA CS
EMA A.1
EMA A.1
EMA A.2
EMA A.2
EMA A.3
EMA A.3
EMA A.4
EMA A.4
EMA A.5.1
EMA A.5.1
EMA A.5.2
EMA A.5.2
EMA A.5.3
EMA A.5.3
EMA A.5.4
EMA A.5.4
EMA A.6.1
EMA A.6.1
EMA A.6.2
EMA A.6.2
EMA A.6.3
EMA A.6.3
EMA A.4.PDF
EMA A.4
EMA A.5.2.PDF
EMA A.5.2

File details come from the government source that posted it. Updated .