10-260902 Construction Plans.pdf

PDF 8 MB Posted

Attached to
Schuylkill County - Emergency Training Facility (0325-900015.01)
Solicitation number
US.251947
Issued by
Somerset County, Pennsylvania

About this file

This is a construction plans document for the Schuylkill County Emergency Training Facility, a project involving the Schuylkill County Volunteer Firemen's Association and municipal authorities across Ryan Township and West Mahanoy Township in Schuylkill County, Pennsylvania. The project, identified as 0325-900015.01, involves the construction of an emergency training facility with multiple plan sheets including site layout, grading and utility plans, erosion and sediment pollution control plans, post-construction stormwater management plans, storm sewer profiles, and construction details. The project encompasses parcel identification numbers 26-06-0016.003 with associated One Call System serial numbers 20230823233 and 20230823234. According to the related contract opportunity, sealed bids for construction are being received through the PennBid Program until October 21, 2026, at 9:00 AM, with a tentative award date of October 28, 2026. The project is being bid as four separate prime contracts: General Construction, Plumbing Construction, HVAC Construction, and Electrical Construction.

Bidders are required to submit a certified check or bank draft in the amount of 10 percent of the total bid as bid security, or an acceptable bid bond naming Schuylkill County as the obligee. The successful bidder must furnish performance and payment bonds in the amount of 100 percent of the contract price with a corporate surety approved by the owner. All bidding documents are available at no cost through PennBid. Davis-Bacon wage rates will apply to this contract. The contractor must comply with non-discrimination requirements regarding race, age, color, religion, sex, national origin, and handicap. Utility coordination is mandatory, requiring notification to the Pennsylvania One Call System at least three and no more than ten business days prior to excavation. The owner reserves the right to waive any informality or reject any or all bids.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Location Map

Cover Sheet1

Drawing Index

Drawing No. Title

N

Rev Date By Chk'd Description

32008.00 kmarmas 09\02\2026 13:02:28 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\01_Cover - Ryan.dgn (Default)

PROJECT

OF1

DRAWING NO.

SCALE IN FEET

1000 1000

PREPARED BY:

PROJECT MANAGER DATE

570-622-4055

Pottsville, Pennsylvania 17901

400 One Norwegian Plaza

Alfred Benesch & Company design information, or any part thereof, is strictly prohibited, except by written permission of this firm.

the property of Alfred Benesch & Company. Use, reuse, reproduction or modification of this plan or

Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is

FOR

Erosion & Sediment Pollution Control Plan

Construction Details

All plan sheets to be recorded.

Storm Sewer Profiles

Erosion & Sediment Pollution Control Details

Site Layout Plan

F

IR

E M

E N 'S R

O A

D

L

IA

R

O A

D

INTERSTATE 81

LOCATION

PROJECT

PARCEL IDENTIFICATION

26-06-0016.003

20230823233, 20230823234

EMA FIRE SCHOOL BUILDING

SCHUYLKILL COUNTY VOLUNTEER FIREMEN'S ASSOCIATION

General Notes

14-15

Post Construction Stormwater Management Plan

Post Construction Stormwater Management Plan Details

11-12

PENNSYLVANIA ONE CALL SYSTEM SERIAL NUMBER

START OF EXCAVATION.

THAN 10 BUSINESS DAYS PRIOR TO THE

LESS THAN 3 BUSINESS DAYS NOR MORE

DIAL 8-1-1 OR 1-800-242-1776 NOT

WWW.PAONECALL.ORG

COORDINATE YOUR PROJECTS VIA COORDINATE PA AT

P E

N N S Y L V

ANI

A

ONE CALL SYST

E

M

I

N C

D I

A L

8-1-1 BEFORE

YO

U

D I

G

Grading & Utility Plan

8-10

SCALE: 1" = 1000'

WEST M

AHANOY T

OWNSHIP

RYAN T

OWNSHIP

Existing Conditions & Demolition Plan and Subdivision Plan

LAND DEVELOPMENT PLAN FOR CONSTRUCTION

0325-900015.01

SEPTEMBER 2, 2026

Schuylkill County, Pennsylvania

Ryan Township and West Mahanoy Township

Sheet No.:Drawn: Designed: Checked:

Rev Date By Chk'd Description

Scale: AS NOTED Date: Project No.:

570-622-4055

Pottsville, Pennsylvania 17901

400 One Norwegian Plaza

Alfred Benesch & Company

32008.00 kmarmas 09\02\2026 13:02:37 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\02_Notes.dgn (Default) reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.

Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, OFKAM KAM KRR 1509/02/2026

West Mahanoy & Ryan Townships, Schuylkill County, Pennsylvania

COUNTY OF SCHUYKILL

FIREMEN'S ASSOCIATION

SCHUYLKILL COUNTY VOLUNTEER

0325-900015.01

GENERAL NOTES

ZONING DATA:

WEST MAHANOY TOWNSHIP

RYAN TOWNSHIP

WEST MAHANOY TOWNSHIP:

570-462-1904 office1@mabswater.com

KIARA TAPIA

SHENANDOAH, PA 17967

PO BOX 110

110 N FERGUSON STREET

BOROUGH OF SHENANDOAH

MUNICIPAL AUTHORITY OF THE

610-297-2461 dlhaupt@pplweb.com

DOUG HAUPT

PAXINOS, PA 17860

437 BLUE CHURCH ROAD

PPL ELECTRIC UTILITIES CORPORATION

michael.spaide@amwater.com

MICHAEL SPAIDE

BERWICK, PA 18603

PO BOX 249

306 WEST FRONT STREET

PENNSYLVANIA AMERICAN WATER

570-874-3589 famainfo@fama874.com

RHONDA FRANTZ

FRACKVILLE, PA 17931

42 S CENTER ST

PO BOX 471

FRACKVILLE AREA MUNICIPAL AUTHORITY

570-462-2958

WMTOFFICE@PTO.NET

MICHAEL MICHALIK

SHENANDOAH, PA 17976

190 PENNSYLVANIA AVENUE

WEST MAHANOY TOWNSHIP

570-454-3841 robert.trently@secv.com

ROBERT TRENTLY

HAZLETON, PA 18201

PO BOX R

380 MAPLEWOOD DRIVE

SERVICE ELECTRIC CABLEVISION INC

570-454-5079 timothy.trently@secv.com

TIMOTHY TRENTLY

HAZLETON, PA 18201

PO BOX R

380 MAPLEWOOD DRIVE

SERVICE ELECTRIC CABLEVISION INC

RYAN TOWNSHIP:

570-467-2771

JIM PALAIO

BARNESVILLE, PA 18214

36 N FIFTH AVENUE

RYAN TOWNSHIP

610-297-2461 dlhaupt@pplweb.com

DOUG HAUPT

PAXINOS, PA 17860

437 BLUE CHURCH ROAD

PPL ELECTRIC UTILITIES CORPORATION

570-454-3841 robert.trently@secv.com

ROBERT TRENTLY

HAZLETON, PA 18201

PO BOX R

380 MAPLEWOOD DRIVE

SERVICE ELECTRIC CABLEVISION INC

20230823233 & 20230823234ONE CALL SYSTEM SERIAL NUMBERS:

3/23/2023DATE:

ONE CALL SYSTEM SERIAL NO. NOTIFICATION:

SAID ACT NO. 121 OF 2008.

REFLECTING SAID INFORMATION ON THESE DRAWINGS ONLY DUE TO THE REQUIREMENTS OF THE

ON THESE DRAWINGS IS CORRECT OR ACCURATE, BUT ALFRED BENESCH & COMPANY IS

GUARANTEE THAT THE INFORMATION RECEIVED PURSUANT TO SAID REQUEST AND AS REFLECTED

ALFRED BENESCH & COMPANY DOES NOT MAKE ANY REPRESENTATION, WARRANTY, ASSURANCE OR

IN SECTION 4, CLAUSE (5) OF SAID ACT."

USER'S DESIGNATED OFFICE ADDRESS AND PHONE NUMBER AS SHOWN ON THE LIST REFERRED TO

SYSTEM, THE TOLL-FREE ONE CALL SYSTEM PHONE NUMBER, AND THE NAME OF THE USER, THE

REQUEST MADE AS REQUIRED BY CLAUSE (2), THE SERIAL NUMBER PROVIDED BY THE ONE CALL

UPON THESE DRAWINGS "THE POSITION AND TYPE OF EACH LINE, AS DERIVED PURSUANT TO THE

3. PURSUANT TO SECTION 4, CLAUSE (3) OF SAID ACT, ALFRED BENESCH & COMPANY HAS SHOWN

EXCAVATION IS TO BE PERFORMED.

OBLIGATION OF CLAUSE (2) BY CALLING THE ONE CALL SYSTEM SERVING THE LOCATION WHERE

2. PURSUANT TO SECTION 4, CLAUSE (5) OF SAID ACT, ALFRED BENESCH & COMPANY HAS MET THEIR

THAN (10) NOR MORE THAN (90) WORKING DAYS BEFORE FINAL DESIGN IS TO BE COMPLETED.

NOTIFICATION, THE INFORMATION PRESCRIBED BY SECTION 2, CLAUSE (4) OF SAID ACT, NOT LESS

FROM EACH USER'S OFFICE DESIGNATED ON SUCH LIST PROVIDED BY THE ONE CALL SYSTEM

1. PURSUANT TO SECTION 4, CLAUSE (2) OF SAID ACT, ALFRED BENESCH & COMPANY REQUESTED

POLITICAL SUBDIVISION(S) SHOWN ON THE DRAWINGS:

PREPARING THESE DRAWINGS REQUIRING EXCAVATION OR DEMOLITION WORK AT SITES WITHIN THE

OF 1974, AS AMENDED THE PENNSYLVANIA LEGISLATURE, IT HAS PERFORMED THE FOLLOWING IN

ALFRED BENESCH & COMPANY HERBY STATES THAT , PURSUANT TO THE PROVISIONS OF ACT NO. 287

ACT 287 NOTIFICATION

LIST OF UTILITIES

https://www.pa1call.org/ResourceLibrary/Resource/category/Toolkit

DESIGNER LABEL FROM POCS WEBSITE TOOLKIT

PENNSYLVANIA ONE CALL SYSTEM SERIAL NUMBER

20230823233, 20230823234

START OF EXCAVATION.

THAN 10 BUSINESS DAYS PRIOR TO THE

LESS THAN 3 BUSINESS DAYS NOR MORE

DIAL 8-1-1 OR 1-800-242-1776 NOT

WWW.PAONECALL.ORG

COORDINATE YOUR PROJECTS VIA COORDINATE PA AT

P E

N N S Y L V

ANI

A

ONE CALL SYST

E

M

I

N C

D I

8-1-1 BEFORE

U

D I

G

EXISTING CONDITIONS & DEMOLITION PLAN NOTES

PLAN NOTES

REQUIRED PROVIDED

* INCLUDES PORTION OF PROPERTY IN WEST MAHANOY TOWNSHIP.

<4 STORIES4 STORIES

<70 FEET70 FEET9. MAXIMUM BUILDING HEIGHT:

12.6%30%8. MAXIMUM LAND COVERAGE:

224.9 FEET*50 FEET7. MINIMUM SIDE COMBINED:

108 FEET25 FEET6. MINIMUM SIDE YARD:

109 FEET25 FEET5. MINIMUM REAR YARD:

145 FEET50 FEET4. MINIMUM FRONT YARD:

305 FEET*200 FEET3. MINIMUM LOT WIDTH:

430 FEET200 FEET2. MINIMUM LOT DEPTH:

67,077 SQUARE FEET40,000 SQUARE FEET 1. MINIMUM LOT AREA:

(SERVED BY CENTRAL SEWAGE DISPOSAL)

ZONING DISTRICT: I-2 LIGHT INDUSTRIAL

REQUIRED PROVIDED

* INCLUDES PORTION OF PROPERTY IN RYAN TOWNSHIP.

<35 FEET35 FEET8. MAXIMUM BUILDING HEIGHT:

8.8%60%7. MAXIMUM BUILDING COVERAGE:

224.9 FEET*50 FEET6. MINIMUM SIDE COMBINED:

116.9 FEET25 FEET5. MINIMUM SIDE YARD:

109 FEET25 FEET4. MINIMUM REAR YARD:

145 FEET35 FEET3. MINIMUM FRONT YARD:

305 FEET*75 FEET2. MINIMUM LOT WIDTH:

64,067 SQUARE FEET10,000 SQUARE FEET 1. MINIMUM LOT AREA:

(SERVED BY CENTRAL SEWAGE DISPOSAL)

ZONING DISTRICT: I INDUSTRIAL

PLAN INTENT

CURRENTLY BOTH MAKE UP.

ASSESSMENT PARCELS INSTEAD OF THE SINGLE TAX ASSESSMENT PARCEL THEY

THE PROPOSED LAND DEVELOPMENT, BE SEPARATED INTO TWO SEPARATE TAX

PLAN IS ALSO REQUESTING THAT THE TWO PROPERTIES, ONE OF WHICH WILL CONTAIN

PARKING LOT TO BE USED BY THE COUNTY EMA AND FOR FIRE FIGHTER TRAINING. THIS

THE PURPOSE OF THIS PLAN IS A LAND DEVELOPMENT FOR A PROPOSED BUILDING WITH

SUBDIVISION: TAX ASSESSMENT PARCEL SEPARATION

LINES AS PART OF THIS SUBDIVISION.

ARE SEPARATELY DEEDED PROPERTIES AND THEREFORE THERE ARE NO PROPOSED LOT

SAME OWNERSHIP AS INDICATED IN GENERAL NOTE 7 ON THIS SHEET; HOWEVER, THEY

(26-06-0016.003) INTO TWO SEPARATE TAX PARCELS. BOTH PROPERTIES ARE UNDER THE

PROPERTIES THAT MAKE UP THE SINGLE TAX ASSESSMENT PARCEL NUMBER

THESE PLANS ARE ALSO REQUESTING TO SEPARATE THE TWO SEPARATELY DEEDED

GRADING & UTILITY PLAN NOTES

CONNECTION LOCATION WITH FAMA.

INSTALLED SEPARATELY BY FAMA. CONTRACTOR TO COORDINATE

TO THE LOW PRESSURE SANITARY SEWER MAIN THAT WAS PREVIOUSLY

PROPOSED SANITARY SEWER SERVICE FOR THIS PROJECT IS TO CONNECT

THE EAST SIDE OF FIREMAN'S ROAD AS PART OF A SEPARATE PROJECT.

FAMA ALSO INSTALLED A LOW PRESSURE SANITARY SEWER MAIN ALONG

REMOVAL WAS COMPLETED PRIOR TO COMMENCEMENT OF THIS PROJECT.

SEPARATE PROJECT THAT WAS COMPLETED BY FAMA. THE PUMP STATION

STATION ALONG FIREMEN'S ROAD HAS BEEN REMOVED AS PART OF A

THE EXISTING FRACKVILLE AREA MUNICIPAL AUTHORITY (FAMA) PUMP 17.

RESULT OF THIS PROJECT.

THERE ARE NO NATURAL STEEP SLOPES THAT WILL BE DISTURBED AS A 16.

WOODED AREAS WILL BE DISTURBED AS A RESULT OF THIS PROJECT.

GROWN WITHIN THE AREA OF PROPOSED IMPROVEMENTS. NO EXISTING

REMOVAL WILL BE MINIMAL AND CONSIST OF REMOVAL OF BRUSH THAT HAS

CONSIDERING THE MAJORITY OF THE SITE IS A GRASS AREA, VEGETATION 15.

EACH DAY.

PEDESTRIANS, ETC. CLOSE ALL EXCAVATIONS AND MAKE SAFE AT END OF

PROVIDE MAINTENANCE AND PROTECTION OF TRAFFIC FOR VEHICLES,

CONSTRUCTION. CONTRACTOR TO COORDINATE WITH OWNER AND

COUNTY VOLUNTEER FIREMEN'S ASSOCIATION DURING DEMOLITION AND

THE AREA ADJACENT TO THE SITE MAY BE IN USE BY THE SCHUYLKILL 14.

UTILITY OWNER(S) AND/OR PROVIDER(S).

RELOCATED ACCORDINGLY AND IN COORDINATION WITH CORRESPONDING

RELOCATED OR IMPACTED BY THE PROPOSED IMPROVEMENTS SHALL BE

EXISTING OVERHEAD UTILITY LINES SERVING ANY EXISTING FEATURE BEING 13.

UTILITY POLES AND THE EXTENTION OF ALL PROPOSED UTILITIES.

COMPANY ON THE ADDITION, REMOVAL AND/OR RELOCATION OF UTILITIES,

CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE UTILITY 12.

OF ALL UNDERGROUND UTILITIES.

COMPANIES IN ACCORDANCE WITH ACT 287 TO VERIFY AN EXACT LOCATION

THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY

PRIOR TO ANY EARTH MOVING ACTIVITIES ON THE PROPERTY, IT SHALL BE 11.

VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION.

PERFORMED. ALL EXISTING UTILITIES SHOWN HEREON MUST BE FIELD

CALL SYSTEM. NO SUBSURFACE LOCATION OR LOCATION SERVICES WERE

FIELD LOCATIONS AND UTILITIES MARKED IN RESPONSE TO THE PA ONE

UNDERGROUND UTILITIES SHOWN HEREON ARE BASED IN PART ON VISIBLE 10.

UNDERGROUND STRUCTURES.

DETERMINE THE EXISTENCE AND EXACT LOCATION OF ALL UTILITIES AND

BE SHOWN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO

AND UNDERGROUND STRUCTURES ARE APPROXIMATE AND MAY NOT ALL

NOTIFY PA ONE CALL AT 1-800-242-1776. THE LOCATION OF ALL UTILITIES

287 - PA ONE CALL NOTIFICATION OF UTILITIES. THE CONTRACTOR SHALL

THE FIELD IN ACCORDANCE WITH ALL APPLICABLE REGULATIONS OF ACT

BEFORE EXCAVATION, ALL UNDERGROUND UTILITIES SHALL BE LOCATED IN 9.

INDICATED OTHERWISE, ALSO SEE NOTE 3.

FEATURES SHOWN IN BOLD INDICATE ITEMS TO BE REMOVED UNLESS 8.

DAMAGED ITEM SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE.

CONDITIONS. IF DAMAGE CANNOT BE REPAIRED ADEQUATELY, THE

PROCESS SHALL BE REPAIRED AND RESTORED TO PRE-DEMOLITION

DAMAGE CAUSED TO EXISTING FEATURES DURING THE DEMOLITION 7.

THE WEATHER SHALL BE STORED IN A SECURE AND DRY LOCATION.

AND SECURE LOCATION. MATERIAL THAT REQUIRES PROTECTION FROM

FROM THE SITE. MATERIALS TO BE REUSED WILL BE STOCKPILED IN A SAFE

UNUSABLE MATERIALS AND RUBBISH SHALL BE IMMEDIATELY REMOVED 6.

CONFORMING MANNER.

UTILITIES WHERE ITEMS ARE BEING REMOVED IN A SAFE AND CODE

THE CONTRACTOR IS RESPONSIBLE FOR TERMINATING ALL APPLICABLE 5.

MARKED TO ENSURE WORKER AND PUBLIC SAFETY.

SHALL BE COVERED OR FENCED OFF, THE AREA SHALL BE ADEQUATELY

EXCAVATIONS THAT ARE LEFT OPEN DURING THE DEMOLITION PROCESS 4.

SHALL BE PROVIDED TO EXISTING FEATURES NOT BEING REMOVED.

THE CONSTRUCTION DOCUMENTS. ADEQUATE AND PROPER PROTECTION

PROPOSED BUILDING AND SITE FEATURES WHETHER OR NOT INDICATED IN

CONTRACTOR TO DEMOLISH ALL ITEMS NECESSARY TO CONSTRUCT THE 3.

CONTRACTOR AND DISPOSED OF AT AN APPROVED FACILITY.

PROJECT SITE MUST BE REMOVED BY A LICENSED HAZARDOUS MATERIAL

ANY EXISTING HAZARDOUS WASTE ENCOUNTERED IN PREPARATION OF THE 2.

RECORD SHALL BE CONTACTED IMMEDIATELY.

DISCREPANCY BETWEEN FIELD AND PLAN CONDITIONS, THE ENGINEER OF

CONTRACTOR PRIOR TO CONSTRUCTION. IN THE EVENT OF ANY

SITE SHALL AND SHOWN ON THIS PLAN SHALL BE FIELD VERIFIED BY

ALL EXISTING CONDITIONS, DIMENSIONS, INVERTS AND ELEVATIONS ON THE 1.

INTERSECTING DRIVEWAY AND STREET.

HEIGHT OF TEN (10) FEET MEASURED FROM THE CENTERLINE GRADES OF THE

WHICH OBSCURES VISION ABOVE THE HEIGHT OF THIRTY (30) INCHES AND BELOW THE

NO VISION OBSTRUCTING OBJECTS ARE PERMITTING WITHIN THE CLEAR SIGHT TRIANGLES 19.

ACCESSES.

BUILDING ACCESS POINTS SHALL BE ADJUSTED IF NECESSARY TO LINE UP WITH BUILDING

EXACT LOCATION OF ACCESS POINTS INTO THE BUILDING. SIDEWALK SECTIONS LEADING TO

SHALL BE CONFIRMED WITH THE ARCHITECTURAL PLANS. SEE ARCHITECTURAL PLANS FOR

THE SIDEWALK SYSTEMS AND ACCESS POINTS INTO THE BUILDING AS SHOWN ON THIS PLAN 18.

JULY 23, 2024. NPDES PERMIT #: PAC-54-0151

BEEN OBTAINED FROM SCHUYLKILL CONSERVATION DISTRICT/PADEP FOR THIS PROJECT ON

EROSION AND SEDIMENT POLLUTION CONTROL PLAN APPROVAL AND NPDES PERMIT HAS 17.

PROJECT SITE OTHER THAN THE POND AS SHOWN PARCEL 2.

WETLAND INVENTORY WEBSITE, THERE ARE NO WELTANDS OR WATERCOURSES ON THE

BASED ON THE WETLANDS MAPPER ON THE U.S. FISH AND WILDLIFE SERVICE - NATIONAL

A WETLAND AND WATERCOURSE DETERMINATION WAS NOT PERFORMED FOR THE SITE. 16.

AT AN APPROVED FACILITY.

MUST BE REMOVED BY A LICENSED HAZARDOUS MATERIAL CONTRACTOR AND DISPOSED OF

ANY EXISTING HAZARDOUS WASTE ENCOUNTERED IN PREPARATION OF THE PROJECT SITE 15.

ALL TRENCHING TO BE IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL LAWS.14.

WATER.

THIS DEVELOPMENT WILL BE SERVED BY PENNSYLVANIA AMERICAN WATER FOR PUBLIC 13.

PUBLIC SEWER.

THIS DEVELOPMENT WILL BE SERVED BY FRACKVILLE AREA MUNICIPAL AUTHORITY FOR 12.

AND OBTAIN ANY REQUIRED SIGN PERMIT PRIOR TO SIGN CONSTRUCTION.

ORDINANCE, DEPENDING ON THE MUNICIPALITY THE SIGN IS PROPOSED TO BE PLACED IN,

OF THE WEST MAHANOY TOWNSHIP ZONING ORDINANCE OR THE RYAN TOWNSHIP ZONING

ANY PROPOSED BUILDING OR SITE SIGN SHALL BE SUBJECT TO THE SIGN REQUIREMENTS 11.

PROVIDED AT THE TIME OF BUILDING PERMIT APPLICATION(S).

THE LAND DEVELOPMENT APPROVAL PURPOSES ONLY. ARCHITECTURAL PLANS SHALL BE

BUILDING DIMENSIONS AND COVERED PARKING AREA SHOWN ON THIS PLAN SET ARE FOR 10.

STRUCTURES. ALL ANGLES ARE 90 DEGREES UNLESS OTHERWISE NOTED.

UNLESS NOTED. ALL BUILDING DIMENSIONS ARE REFERENCED TO THE OUTSIDE FACE OF

ALL SITE DIMENSIONS ARE REFERENCED TO THE FACE OF CURB OR EDGE OF PAVING 9.

VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION ACTIVITIES.

ALL DIMENSIONS, ELEVATIONS, AND INVERTS SHOWN IN THIS PLAN SHALL BE FIELD 8.

PARCEL ACREAGE: 23.963 ACRES (1,043,826.47 SF)

UPI NO. 26-06-0016.003

DEED BOOK 1377, PAGE 112

PARCEL 2:

PARCEL ACREAGE: 3.011 ACRES (131,150.00 SF)

UPI NO. 26-06-0016.003

DEED BOOK 687, PAGE 64

PARCEL 1:

POTTSVILLE, PA 17901

P.O. BOX 535

SCHUYLKILL COUNTY VOLUNTEER FIREMEN'S ASSOCIATION

RECORD OWNER & SOURCE OF TITLE:7.

TO FEMA FIRM MAP NUMBER 42107C0164F, WITH EFFECTIVE DATE MAY 18, 2021.

THE PROPOSED SITE IS NOT LOCATED WITHIN A MAPPED 100-YEAR FLOODPLAIN ACCORDING 6.

OF 1988 (NAVD-88).

(SOUTH ZONE) NAD-83. VERTICAL DATUM IS BASED ON NORTH AMERICAN VERTICAL DATUM

HORIZONTAL DATUM IS BASED ON THE PENNSYLVANIA STATE PLANE COORDINATE SYSTEM 5.

SHOWN ARE TAKEN FROM CURRENT AVAILABLE PASDA LiDAR INFORMATION.

BASED ON A FIELD SURVEY PERFORMED BY BENESCH IN APRIL 2023. ALL OTHER CONTOURS

CONTOUR LINES IN THE AREA OF PROPOSED IMPROVEMENTS DEPICTED ON THIS PLAN ARE 4.

MERIDIAN.

RESTRICTION NOT SHOWN HEREON. BOUNDARY LINE BEARINGS ARE BASED ON DEED

PROPERTIES SHOWN HEREON MAY BE SUBJECT TO EASEMENTS, RIGHT-OF-WAYS AND

THE BOUNDARY SURVEY WAS DONE WITHOUT THE BENEFIT OF A TITLE SEARCH AND THE 3.

PERFORMED BY BENESCH IN APRIL 2023.

BOUNDARY AND EXISTING FEATURES SHOWN ON THIS PLAN ARE BASED ON A FIELD SURVEY 2.

PARKING LOT TO BE USED BY THE COUNTY EMA AND FOR FIRE FIGHTER TRAINING.

THE PURPOSE OF THIS PLAN IS A LAND DEVELOPMENT FOR A PROPOSED BUILDING WITH 1.

AFTER THE BUILDING AND COVERED PARKING AREA.

THESE NOTES FOR INFORMATION ON ALL REMAINING UNDERGROUND ROOF DRAIN PIPES BEYOND THE FIRST CLEANOUT FIRST CLEANOUT AS SHOWN ON THE GRADING AND UTILITY PLAN IN THIS PLAN SET. SEE GRADING AND UTILITY PLAN AND SECTION OF PIPES LEAVING THE BUILDING FOOTPRINT AND LEAVING THE COVERED PARKING AREA FOOTPRINT TO THE SEE PLUMBING PLAN FOR UNDERGROUND ROOF DRAIN PIPE INFORMATION, INCLUDING PIPE DIAMETER, FOR THE FIRST 33.

REQUEST THE SERVICE APPLICATION PACKAGE.

COMPELTED AND SUBMITTED BY CONTRACTOR TO PAW. OWNER/ARCHITECT TO CONTACT PAW (1-800-565-7292) TO PENNSYLVANIA AMERICAN WATER (PAW) TO SIZE THE TAP AND METER AFTER PAW SERVICE APPLICATION PACKAGE IS 32.

ELECTRIC POWER TO THE PROPOSED GRINDER PUMP IS THE RESPONSIBILITY OF THE CONTRACTOR.31.

BEYOND THE RIGHT-OF-WAY OF FIREMENS ROAD.

ROAD TO AT LEAST 20 FEET BEYOND THE RIGHT-OF-WAY OF FIREMENS ROAD, AND SHALL NOT EXCEED 10% SLOPE PROPOSED GRADING ALONG ACCESS DRIVES SHALL NOT EXCEED 5% SLOPE FROM THE INTERSECTION WITH FIREMENS 30.

MOUNDED TOWARDS THE CENTER OF THE ISLAND.

PARKING LOT ISLAND AREAS INDICATED TO BE RIVER ROCK SHALL BE FLUSH WITH EDGE OF PAVING AND SLIGHTLY 29.

PLUMBING PLAN.

PROPOSED SEWER AND WATER SERVICE SIZES AND DETAILS TO BE DESIGNED SEPARATELY AND PROVIDED ON THE 28.

PART OF SEPARATE PROJECT BY FAMA. CONTRACTOR TO COORDINATE WITH FAMA AT TIME OF CONNECTION.

PRESSURE SEWER MAIN LOCATED ALONG THE EAST SIDE OF FIREMEN'S ROAD, WHICH WAS PEVIOUSLY INSTALLED AS SANITARY SEWER SERVICE FOR THIS PROJECT TO CONNECT TO FRACKVILLE AREA MUNICIPAL AUTHORITY'S (FAMA) LOW 27.

LEAST 6" BEYOND THE CLEANOUT PIPE WALL IN ALL DIRECTIONS.

PSI CONCRETE PAD, 6" THICK, SHALL BE PLACED AT THE SURFACE AROUND THE CLEANOUT AND SHALL EXTEND AT SURFACE TO PREVENT A TRIPPING HAZARD. IF CLEANOUT CAP IS INSTALLED WITHIN A DRIVING SURFACE, A SQUARE 3,500 PVC CAP. IF CLEANOUT IS WITHIN A WALKING OR DRIVING SURFACE, CAP SHALL BE INSTALLED TO BE FLUSH WITH TO MATCH DIAMETER OF ACTUAL UNDERGROUND ROOF DRAIN PIPE. CLEANOUT SHALL BE CAPPED WITH A SCREW ON UNDERGROUND ROOF DRAIN PIPE WITH A PVC PIPE TEE CONNECTION. NOTE: DIAMETER OF CLEANOUT DOES NOT NEED UNDERGROUND ROOF DRAIN CLEANOUTS TO BE MINIMUM DIAMETER 4" SDR 35 PVC PIPE CONNECTED TO THE 26.

COMPLY WITH ALL APPLICABLE SAFETY REQUIREMENTS.

CONTRACTOR TO COORDINATE PROPOSED GATES WITH OWNER AND REFER TO ARCHITECTURAL PLANS. GATES SHALL 25.

COUNTY SCREENING AND SEPARATION REQUIREMENTS.

REQUIREMENTS, EQUIPMENT DETAILS AND PROTECTION AS NECESSARY, AND COMPLY WITH ANY MUNICIPAL AND/OR ARCHITECT TO COORDINATE WITH LOCAL GAS PROVIDERS TO DETERMINE TANK SIZE AND LOCATION, TANK PUBLIC GAS SERVICE IS NOT AVAILABLE FOR THIS PROJECT SITE. CONTRACTOR ALONG WITH DEVELOPER AND 24.

BUILDING.

APPROVAL BY, THE RESPECTIVE UTILITY SUPPLIERS. IT IS SHOWN AS AN UNDERGROUND SERVICE TO THE PROPOSED THE ELECTRICAL SERVICE LINES SHOWN ON THE PLANS ARE PRELIMINARY AND WILL REQUIRE COORDINATION WITH, AND 23.

ALL PROPOSED SLOPES SHALL BE 2:1 (HORIZONTAL:VERTICAL) MAXIMUM UNLESS OTHERWISE NOTED.22.

UNLESS OTHERWISE NOTED.

BE STRIPPED AND REMOVED FROM NEW CONSTRUCTION AREAS AND PROPERLY DISPOSED OF AT AN APPROVED SITE ALL EXISTING TREES, VEGETATION, PAVEMENTS, CONCRETE FOUNDATIONS, STRUCTURES AND ORGANIC TOPSOIL SHALL 21.

ADVANCED DRAINAGE SYSTEMS (ADS) OR APPROVED EQUAL, UNLESS OTHERWISE NOTED.

ALL STORM PIPING SHALL BE SMOOTH LINED CORRUGATED POLYETHYLENE PIPE (SLCPP) AS MANUFACTURED BY 20.

ALL ENDWALLS SHALL BE PRECAST CONCRETE TYPE DW ENDWALLS.19.

ALL INLETS OVER 5 FEET IN DEPTH SHALL BE PROVIDED WITH MANHOLE STEPS.18.

SPECIFIED.

ALL INLETS SHALL BE PADOT TYPE M INLETS WITH STRUCTURAL STEEL (BICYCLE SAFE) GRATES UNLESS OTHERWISE 17.

CONTRACTOR IN THE FIELD AND COORDINATED WITH FAMA.

INSTALLED AS PART OF A SEPARATE PROJECT. THIS CONNECTION IS APPROXIMATE AND SHALL BE VERIFIED BY DEPICTING PROPOSED FRACKVILLE AREA MUNICIPAL AUTHORITY (FAMA) SEWER UPGRADES THAT WERE PREVIOUSLY LOCATION OF PROPOSED SANITARY SERVICE CONNECTION TO EXISTING MAIN IS APPROXIMATE AND BASED ON PLANS 16.

WHERE THEY ENTER THE BUILDING.

GAS LINES, AND ELECTRIC CONNECTIONS TO THE PROPOSED BUILDING, INCLUDING SIZE OF LINES AND LOCATIONS SEE ARCHITECTURAL AND/OR PLUMBING PLANS FOR INFORMATION ON SANITARY SEWER LATERAL, WATER SERVICE LINE, 15.

INSPECTION, TESTING AND FINAL ACCEPTANCE OF ALL PROPOSED UTILITIES CONSTRUCTED.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FEES ASSOCIATED WITH THE CONNECTION, INSTALLATION, 14.

APPLICABLE LOCAL AND STATE CODES AND REGULATIONS.

IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BID AND PERFORM ALL UTILITY WORK IN COMPLIANCE TO ALL 13.

WATER.

AND REGULATIONS OF BOTH RYAN TOWNSHIP AND WEST MAHANOY TOWNSHIP, COUNTY, AND PENNSYLVANIA AMERICAN WITH PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION SPECIFICATIONS, AND ALL ORDINANCES, RULES, ALL WATER SUPPLY AND DISTRIBUTION SYSTEMS, PUBLIC OR ON-SITE SHALL BE CONSTRUCTED IN FULL COMPLIANCE 12.

WHETHER PERFORMED BY THE CONTRACTOR OR NOT.

OF THE CONTRACTOR TO ENSURE ALL UTILITIES ARE INSTALLED CORRECTLY TO MEET PROJECT REQUIREMENTS STANDARD SPECIFICATIONS AND PER ALL APPLICABLE PADEP REQUIRMENTS AND STANDARDS. IT IS THE RESPONSIBILITY SANITARY SEWER SPECIFICATIONS SHALL BE IN ACCORDANCE WITH THE FRACKVILLE AREA MUNICIPAL AUTHORITY ALL UTILITIES SHALL BE INSTALLED IN ACCORDANCE WITH THE SPECIFICATIONS OF THE RESPECTIVE UTILITY COMPANY. 11.

NOTED IN THE CONSTRUCTION DRAWINGS, SITE SPECIFICATIONS OR INSTRUCTED BY THE OWNER.

ALL AREAS NOT PAVED OR CONCRETE SHALL BE TOPSOILED, SEEDED, MULCHED OR LANDSCAPED UNLESS OTHERWISE 10.

RELOCATION OF UTILITIES, UTILITY POLES AND THE EXTENTION OF ALL PROPOSED UTILITIES.

CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE UTILITY COMPANY ON THE ADDITION, REMOVAL AND/OR 9.

LOCATION OF ALL UTILITIES AND UNDERGROUND STRUCTURES.

MAY NOT ALL BE SHOWN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXISTENCE AND EXACT ONE CALL AT 1-800-242-1776. THE LOCATION OF ALL UTILITIES AND UNDERGROUND STRUCTURES ARE APPROXIMATE AND APPLICABLE REGULATIONS OF ACT 287 - PA ONE CALL NOTIFICATION OF UTILITIES. THE CONTRACTOR SHALL NOTIFY PA BEFORE EXCAVATION, ALL UNDERGROUND UTILITIES SHALL BE LOCATED IN THE FIELD IN ACCORDANCE WITH ALL 8.

LAWS.

CONSTRUCTION STANDARDS (RC STANDARDS), CURRENT EDITIONS, AND ALL OTHER PERTINENT FEDERAL AND STATE SCHUYLKILL COUNTY, AND IN ACCORDANCE WITH PADOT SPECIFICATIONS, PUBLICATION 408 AND THE ROADWAY MAHANOY TOWNSHIP, THE CURRENT REQUIREMENTSM OF RYAN TOWNSHIP, THE CURRENT REQUIREMENTS OF ALL SITE WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS, THE CURRENT REQUIREMENTS OF WEST 7.

FOR THE OWNER'S AND ENGINEERS'S REVIEW PRIOR TO CONSTRUCTION.

FOR ANY ITEMS NOT COVERED BY DETAILS OR SPECIFICATIONS, THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS 6.

CONSTRUCTION EASEMENTS.

NO WORK SHALL OCCUR OUTSIDE OF THE PROPERTY OR RIGHT-OF-WAY LINES UNLESS COVERED BY GRADING OR 5.

NOTED.

ALL SPOT ELEVATIONS ARE REFERENCED TO THE FINISHED PAVEMENT OR GROUND SURFACE UNLESS OTHERWISE 4.

TIE INTO EXISTING GRADES NO CLOSER THAN 3 FEET FROM ANY PROPERTY LINE UNLESS OTHERWISE AUTHORIZED.

FINISHED EARTHEN SLOPES SHALL BE ROUNDED TO PROVIDE A UNIFORM AND AESTHETIC LANDSCAPE. GRADING SHALL ALL FINAL SITE GRADING SHALL BE SMOOTH AND EVEN AND WITHOUT ABRUPT BREAKS OR CHANGES IN GRADE. 3.

INCLUDING STEPS AND LANDINGS, AND UTILITY SERVICE POINTS.

COORDINATION WITH FINAL BUILDING DESIGN IS REQUIRED TO CONFIRM BUILDING DIMENSIONS, ACCESS LOCATIONS 2.

CONDITIONS, THE ENGINEER OF RECORD SHALL BE CONTACTED IMMEDIATELY.

VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. IN THE EVENT OF ANY DISCREPANCY BETWEEN FIELD AND PLAN ALL EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS ON THE SITE AND SHOWN ON THIS PLAN SHALL BE FIELD 1.

Scale: AS NOTED Date: Project No.:

570-622-4055

Pottsville, Pennsylvania 17901

400 One Norwegian Plaza

Alfred Benesch & Company

32008.00 kmarmas 09\02\2026 13:02:50 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\03_Ex_Condition.dgn (Default) reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.

Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, OFKAM KAM KRR 1509/02/2026

West Mahanoy & Ryan Townships, Schuylkill County, Pennsylvania

COUNTY OF SCHUYKILL

FIREMEN'S ASSOCIATION

SCHUYLKILL COUNTY VOLUNTEER

0325-900015.01

WVCS

W

WVCS

W

W

WVCS

POND

POND

BM

"B"

BM

"A"

0 200100 FEET

SR 0

(S

OUTHBOUND)

SR 00

81 (

N0RTHBOUND)

1. SEE PLAN NOTES SHEET IN THIS PLAN SET FOR ALL NOTES.

NOTES:

F I

R E

M E

N S

R O

A D

RI

GHT-

OF-

WAY

WI

DE

UPI #26-06-0017.900

AND LIGHT COMPANY

N/F PENNSYLVANIA POWER

UPI #26-06-0016.000

DEVELOPMENT CORPORATION

N/F SCHUYLKILL ECON0MIC

CHAI

NLI

NK

FENCE

W/

BARBED

WI

RE

BRUSH

LI

NE

RESTROOMS

BRI

CK

BLDG

BLDGFRAME

BLDGBLOCK

GRAVEL

CONTROLS

GATE

PPL

9-

S5

UPI #26-06-0018.000

N/F JMB LTD

UPI #36-06-0006.000

N/F GPIDC

UPI #36-06-0006.012

N/F MARIANNE M. MCANDREW

-P

SK6

-5

30W

\UNDG

WEST

MAHANOY

TOWNSHI

P

RYAN

TOWNSHI

P

I

PI

N (F

ND)

I

PI

N (F

ND)

I

PI

N (F

ND)

I

PI

N (F

ND)

METER

POLE

NO

INFO

I

PI

N (F

ND)

WV

EXISTING LEGEND

S

E

ARC-1

,06

0.3 6'

TAN-5

31.

07'RAD-7

,47

8.4 9'

-88.40

BLDGBLOCK

BLDGBLOCK2

STORY

CONCRETE

PAD

PAVI

LI

ON

CONCRETE P

AD

BUILDINGBLOCK

SHED

GARAGE

4 STALL BLDG

CONC

3 STORY

BLDG

PAD

CONCRETE

EXISTING CONDITIONS & DEMOLITION PLAN

CHAINLINK FENCE W/BARBED WIRE

(PARCEL 1)

3.011 ACRES

UPI #26-06-0016.003

BK 0687 PG 0064

FIREMEN'S ASSOCATION

SCHUYLKILL COUNTY

(PARCEL 2)

23.963 ACRES

UPI #26-06-0016.003

BK 1377 PG 0112

FIREMEN'S ASSOCATION

SCHUYLKILL COUNTY

BRUSH

CARTWAY

(TBR)

TBR TO BE REMOVED

MUNICIPAL BOUNDARY

BUILDING SETBACK LINE

LEGAL RIGHT-OF-WAY LINE

EXISTING WOODS/BRUSH LINE

EXISTING WETLANDS

EXISTING STREAMS/EDGE OF WATER

EXISTING PROPERTY LINE

EXISTING DRIANAGE PIPE

EXISTING WATER VALVE

EXISTING WATERLINE

EXISTING GUIDERAIL

EXISTING EDGE ROAD / SHOULDER

EXISTING MINOR CONTOUR

EXISTING MAJOR CONTOUR

EXISTING FENCE

FOR L

IMITED ACCESS

LEGAL R

IGHT-OF-WAY L

INE

FOR LIMITED ACCESS

LEGAL RIGHT-OF-WAY LINE

WEST

MAHANOY

TOWNSHI

P

RYAN

TOWNSHI

P

UPI #26-06-0019.000

N/F JMB LTD

(FENCE ALONG FIREMEN'S ROAD TBR)

EXISTING STORM SEWER INFORMATION

EX-

IN1

EX-

IN2

EX-

IN3

EX-

HW1

INVERT=1484.48'

15" RCP

EX-HW1

15" CMP

INVERT (E)=1480.94'

TOP=1483.14'

INLET=4 X 2.2

EX-IN4

30" RCP

INVERT (S)=1479.11'

30" CPP

INVERT (N)=1479.11'

15" RCP

INVERT (W)=1482.81'

TOP=1487.81'

INLET=4 X 2.2

EX-IN3

15" CPP

INVERT (E)=1491.68'

30" CPP

INVERT (N)=1480.50'

30" CPP

INVERT (S)=1480.50'

TOP=1492.70'

INLET=4 X 2.2

EX-IN2

12" CPP

INVERT (N)=1481.26'

15" CPP

INVERT (W)=1481.25'

TOP=1484.39'

INLET=4 X 2.2

EX-IN1

EX-

IN4

METERWATER

METERWATER

PUMP

STATI

ON

FAMA

SANI

TARY

WATER

METER

VALVE

YARD

HYDRANT WV(

3)

PPL

9-

S5

GARAGE

CHANNEL

EXI

STI

NG

CHANNEL

EXI

STI

NG

SUBDIVISION: TAX ASSESSMENT PARCEL SEPARATION

AND SUBDIVISION PLAN

TAX PARCELS

TO CREATE SEPARATE

EXISTING DEED LINE

ALONG THE EXISTING DEED LINE AS SHOWN ON THIS PLAN.

LOT LINES AS PART OF THIS SUBDIVISION. THE TAX PARCEL SEPARATION WILL BE

THEY ARE SEPARATELY DEEDED PROPERTIES AND THEREFORE THERE ARE NO PROPOSED

THE SAME OWNERSHIP AS INDICATED IN GENERAL NOTE 7 ON THIS SHEET; HOWEVER,

(26-06-0016.003) INTO TWO SEPARATE TAX PARCELS. BOTH PROPERTIES ARE UNDER

PROPERTIES THAT MAKE UP THE SINGLE TAX ASSESSMENT PARCEL NUMBER

THESE PLANS ARE ALSO REQUESTING TO SEPARATE THE TWO SEPARATELY DEEDED

ELEV=1505.97'

PROPERTY CORNER (FND)

IRON PIN W/ ALUMINUM CAP

BM "B"

ELEV=1482.57'

OF THE CUL-DE-SAC OF FIREMAN'S ROAD

MAGNAIL SET IN PAVE AT THE SOUTH END

BM "A"

CHAINLINK FENCE W/BARBED WIRE

(FENCE ALONG NORTHERN PERIMETER TO BE REPLACED)

CHAINLINK FENCE W/BARBED WIRE

(FENCE ALONG WESTRERN PERIMETER TO BE REPLACED)

BY

FAMA)PROJ

ECT

COMPLETED

OF

SEPARATE

(REMOVED

AS

PART

(APPROXI

MATE

LOCATI

ON)

FAMA

LOW

PRESSURE

FORCE

MAI

N

BxB

W

UM

W

HGC

BxB

HGB

UM

UM

UM

I PIN (FND)

WVCS

W

WVCS

SAN CO

MH

W

NO INFO

W

I PIN (FND)

W \UNDG

PPL 42859-S52961

WVCS

MH

HYDRANT

YARD

WV CS'S

WV

CONTROLS

GATE

I PIN (FND)

WV CS

METER

WATER

METER POLE

NO INFO

S52983

PPL 42849-

SAN CO

SAN CO

0215-PSK6-530

W \UNDG

TOWER

GRAVEL

G R

A V

E L

WATER

METER

METER

WATER

CHAINLINK FENCE W/BARBED WIRE

INV=1481.80'

TOP OF CO

MH

GARAGE

RYAN TOWNSHIP

WEST MAHANOY TOWNSHIP

F I

R E

M E

N

A D

Sheet No.:Drawn: Designed: Checked:

Rev Date By Chk'd Description

Scale: AS NOTED Date: Project No.:

570-622-4055

Pottsville, Pennsylvania 17901

400 One Norwegian Plaza

Alfred Benesch & Company

32008.00 kmarmas 09\02\2026 13:03:04 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\04_Pr_Site.dgn (Default) reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.

Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, OFKAM KAM KRR 1509/02/2026

West Mahanoy & Ryan Townships, Schuylkill County, Pennsylvania

COUNTY OF SCHUYKILL

FIREMEN'S ASSOCIATION

SCHUYLKILL COUNTY VOLUNTEER

0325-900015.01

0 6030 FEET

SITE LAYOUT PLAN

WV

3,200 S.F.

GARAGE

PROPOSED

176'

40'136'

300'

290'

(TYP)

20'

T

Y P

(TYP)

10'

(TYP)

5'

T

Y P

12'

R=5' R=2'R=5'

R=2'

R=2'

R=5'

13'

R=2' R=5'

R=20'

R=5'

R=10'

R=10'

10 9

9 10 10

18 12

29'

24'

24'

24'

104'

98'20'

20'

88'

(TYP)

R=5'

29'35'

34'

(TYP)

R=5'

R=20'

R=10'

R=10'

R=10'

22'

'9

4'

(TYP)

5'

22'

22'

R=5'

10,880 S.F.

BUILDING

PROPOSED

GATE

GATE

(TYP)

R=2'

(TYP)

R=2'

25'

25' 50'

35'

BUILDING SETBACK LINE (TYP)

(TYP)

R=2' R=2'

TOTAL PROPOSED PARKING SPACES = 116 SPACES

TOTAL REQUIRED BY WEST MAHANOY TOWNSHIP ZONING ORDINACE = 41 SPACES

(3 TRAINING ROOMS WITH 45 OCCUPANTS PER ROOM = 135 SEATS /17 = 8 SPACES

TRAINING SCHOOL (1 SPACE FOR EACH 17 CLASSROOM SEATS):

(10,880 SF (DOES NOT INCLUDE GARAGE)/1,000 = 10.88 X 3 = 32.64 SPACES

OFFICES (3 SPACES FOR EACH 1,000 SF OF FLOOR AREA):

REQUIRED FOR ENTIRE SITE:

PARKING ANALYSIS - WEST MAHANOY TOWNSHIP

PARKING ANALYSIS - RYAN TOWNSHIP

TOTAL PROPOSED PARKING SPACES = 116 SPACES

TOTAL REQUIRED BY RYAN TOWNSHIP ZONING ORDIANCE = 64 SPACES

(3 TRAINING ROOMS WITH 45 OCCUPANTS PER ROOM = 135 SEATS/5 = 27 SPACES

TRAINING SCHOOL (1 SPACE FOR EACH 5 CLASSROOM SEATS)

(10,880 SF (DOES NOT INCLUDE GARAGE)/300 = 36.27 SPACES

OFFICES (1 SPACE FOR EACH 300 SF OF FLOOR AREA

REQUIRED BY ENTIRE SITE:

ADA PARKING SPACE ANALYSIS

ADA SPACES PROPOSED = 6 SPACES

ADA SPACES REQUIRED = 5 SPACES

11'

ACCESSIBLE

VAN

ACCESSIBLE

VAN

11'

(SEE DETAIL)

ADA SIGNAGE (TYP)

BUMPER (TYP)

CONCRETE CAR

GATE

GATE

LEGEND

30" X 30"

STOP SIGN

30" X 30"

STOP SIGN

DWS DWS

DWS DWS

DWS

DWS

LANDING

DOOR

VERTICAL CURB

ISLAND WITH

PROPOSED CONCRETE

VERTICAL CURB

ISLAND WITH

PROPOSED CONCRETE

TRIANGLE

40' CLEAR SIGHT

TRIANGLE

40' CLEAR SIGHT

ASSUMED SPEED LIMIT 35 MPH

SPEED LIMIT NOT POSTED

ASSUMED SPEED LIMIT 35 MPH

SPEED LIMIT NOT POSTED

PROVIDED SIGHT DISTANCE = 360'

DISTANCE TABLE

BASED ON PENNDOT FORMULA SIGHT

REQUIRED SIGHT DISTANCE = 286'

PROVIDED SIGHT DISTANCE = 510'

DISTANCE TABLE

BASED ON PENNDOT FORMULA SIGHT

REQUIRED SIGHT DISTANCE = 275'

PAINT LINES

4" YELLOW

PAINT LINES

4" YELLOW

10'

6'

PARKING)(TYP)

(NON ADA

PAINT LINES

4" YELLOW

PAINT LINES

4" YELLOW

PAINT LINES

4" YELLOW

LINES

PAINT

4" BLUE

ENTRANCE

LENGTH OF THE ROAD TO THE GATED

DISTANCE EXTENDS TO THE REMAINING

PROVIDED SIGHT DISTANCE = SIGHT

ENDS AT SOUTHERN END OF SITE.

REQUIRED SIGHT DISTANCE = N/A - ROAD

ENTRANCE

LENGTH OF THE ROAD TO THE GATED

DISTANCE EXTENDS TO THE REMAINING

PROVIDED SIGHT DISTANCE = SIGHT

ENDS AT SOUTHERN END OF SITE.

REQUIRED SIGHT DISTANCE = N/A - ROAD

ELEV=1505.97'

PROPERTY CORNER (FND)

IRON PIN W/ ALUMINUM CAP

BM "B"

ELEV=1482.57'

OF THE CUL-DE-SAC OF FIREMAN'S ROAD

MAGNAIL SET IN PAVE AT THE SOUTH END

BM "A"

BM "A"

BM "B"

(TYP.)

LEGENDS

PAINT

ARROW

WHITE 11

COORDINATES

POINT NORTHING EASTING

LOCATION AND HEIGHT)

(MATCH EXISTING FENCE TYPE,

REPLACE ALL EXISTING FENCE

PROPOSED FENCE REPLACEMENT

COORDINATE POINT LOCATION

PROPOSED DETECTABLE WARNING SURFACE

PROPOSED PARKING SPACE COUNT

PROPOSED RIVER ROCK

PROPOSED CONCRETE

PROPOSED PAVING

MUNICIPAL BOUNDARY

BUILDING SETBACK LINE

LEGAL RIGHT-OF-WAY LINE

EXISTING WOODS/BRUSH LINE

EXISTING WETLANDS

EXISTING STREAMS / EDGE OF WATER

EXISTING PROPERTY LINE

EXISTING DRIANAGE PIPE

EXISTING WATER VALVE

EXISTING WATERLINE

EXISTING GUIDERAIL

EXISTING EDGE ROAD / SHOULDER

EXISTING MINOR CONTOUR

EXISTING MAJOR CONTOUR

EXISTING FENCE

ALL 11.5' IN WIDTH

6 COVERED PARKING SPACES

LINES

PAINT

4" BLUE

LATERAL CLEANOUT

PAD FOR SANITARY

PROPOSED CONCRETE

529679.2810

529682.7166

529825.7181

529598.8469

529591.2871

529596.1043

529616.3295

529642.3165

529649.3393

529663.5447

529691.9722

529690.9267

529757.2188

529767.7345

529756.5142

529770.7197

529769.8607

529712.4905

529721.9772

529728.0790

529709.1384

529683.3041

529759.0636

529626.7854

529702.5449

529556.6104

529540.3046

529587.8599

529570.8134

529621.5802

529604.5337

529633.4368

529653.9831

529680.4915

529703.2001

529676.9360

529819.9375

529799.5538

529823.5935

529846.3970

529824.5305

529850.6770

529801.5159

529818.5624

529767.7956

529784.8421

529727.0757

529754.3333

2396880.3272

2396934.0526

2396885.5596

2396615.1097

2396620.8411

2396635.0466

2396632.4118

2396765.0944

2396776.4626

2396771.6454

2396827.4507

2396808.7984

2396786.3182

2396801.7590

2396740.6466

2396735.8294

2396723.9549

2396576.5723

2396576.5230

2396594.5166

2396600.9395

2396801.8782

2396776.1892

2396635.1982

2396609.5093

2396580.8596

2396607.5077

2396691.6949

2396697.4755

2396791.1330

2396796.9136

2396882.1463

2396880.4586

2396958.6293

2396950.8626

2396917.0060

2396868.5130

2396839.5418

2396910.4327

2396902.9459

2396838.4635

2396819.0377

2396730.1154

2396724.3347

2396630.6772

2396624.8966

2396523.0534

2396534.9288

TYP. (2)

BOLLARDS

TYP. (2)

BOLLARDS

SEE PLAN NOTES SHEET IN THIS PLAN SET FOR ALL NOTES.1.

NOTES:

TOTAL BOLLARDS)

NEEDED AROUND PROPOSED GENERATORS OR EQUIPMENT. (20

EIGHT (8) ADDITIONAL BOLLARDS TO ACCOUNT FOR ANY

TWELVE (12) BOLLARDS ARE SHOWN ON THE PLANS. INCLUDE 2.

TYP. (4)

BOLLARDS

BOLLARDS TYP. (4)

W

WVCS

W

NO INFO

W

W \UNDG

PPL 42859-S52961

WVCS

CONTROLS

GATE

METER POLE

NO INFO

S52983

PPL 42849-

0215-PSK6-530

W \UNDG

TOWER

GRAVEL

G R

A V

E L

BRUSH LINE

CHAINLINK FENCE W/BARBED WIRE

OPEN FIELD

(GRASS/STONE)

GARAGE

F I

R E

M E

N

A D

XXX

X X X

1495.85 1495.851495.851495.85

X X

X X X 1496.20

1496.201496.20

X

1496.24

X X X X

X 1496.24

1496.24

1496.24 1496.24

1496.201496.20

1495.80

1496.25

XX

1496.20 X 1496.10

X 1495.00

X 1495.00

X1495.55

X 1495.25

X 1495.30

X 1495.20

1495.85 X

1495.00 X

1495.00 X

1495.00 X

1494.70 X

1495.00 X

1495.40 X

1495.00 X

X 1494.30

X 1494.60

1492.75 X

X

1496.20

1495.85 X

X

1496.20 X

1496.20 X X X

1496.20 1496.20

X

1496.24

X

1496.24

1496.24 1496.24

X X X X X

1496.27

X1496.15

X 1495.00

X1495.55

X 1495.20

X 1495.00

X

1495.20 1495.20

X 1495.20

X 1495.20

X

1495.40 X

1495.40 X

1495.40 X

1495.40 X

1495.40

X

1495.40

X

1494.80

X

X

X

1493.50

X

1493.75

X

X

1493.75

X

X

1493.75

X

X 1493.00

X 1493.00

X 1495.20

X 1495.85

X 1495.85

X 1495.85

X

X

X X

1495.64

1495.50

1495.50

X X

1495.64

1495.55

1494.60

X

1495.50

1495.64

X 1494.70

1494.65

1494.70

1494.70

1495.86

X X

1495.85 1495.55

X 1495.64

Sheet No.:Drawn: Designed: Checked:

Rev Date By Chk'd Description

Scale: AS NOTED Date: Project No.:

570-622-4055

Pottsville, Pennsylvania 17901

400 One Norwegian Plaza

Alfred Benesch & Company

32008.00 kmarmas 09\02\2026 13:03:06 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\05_Pr_Grading.dgn (Default) reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.

Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, OFKAM KAM KRR 1509/02/2026

West Mahanoy & Ryan Townships, Schuylkill County, Pennsylvania

COUNTY OF SCHUYKILL

FIREMEN'S ASSOCIATION

SCHUYLKILL COUNTY VOLUNTEER

0325-900015.01

IN0-0

PROPOSED LEGEND

GP

PROPOSED WOODS/BRUSH LINE

PROPOSED RIPRAP

PROPOSED ENDWALL/HEADWALL

PROPOSED STORM INLET & STRUCTURE LABEL

PROPOSED STORM PIPE

PROPOSED GRINDER PUMP

PROPOSED SANITARY FORCE MAIN

PROPOSED SANITARY SEWER LINE

PROPOSED WATER LINE & GATE VALVE

PROPOSED UNDERGROUND ELECTRIC LINE, TELCOM LINE

PROPOSED MINOR CONTOUR

PROP0SED MAJOR CONTOUR

OS-1

IN1-1

IN1-2

IN3-1

EW1

15"

OS-2

0 6030 FEET

SITE GRADING & UTILITY PLAN

WV

EXISTING LEGEND

1. SEE PLAN NOTES SHEET IN THIS PLAN SET FOR ALL NOTES.

NOTES:

EMERGENCY SPILLWAY

EMERGENCY SPILLWAY

EMERGENCY SPILLWAY

BOTTOM ELEV 1485.00

RAIN GARDEN 2 (BMP 5)

BOTTOM ELEV 1490.75

RAIN GARDEN 1 (BMP 3)

SWALE 2

FFE 1496.30

10,880 S.F.

BUILDING

PROPOSED

UNDERGROUND ROOF DRAINS (TYP.)

UNDERGROUND ROOF DRAIN PIPE INFORMATION

INV. 1488.90 INV. 1487.75

INV. 1491.50

INV. 1490.75

BOTTOM ELEV = 1487.75

PERMANENT INFLITRATION BASIN 2 (BMP 2)

CLEANOUTS.

ADDITIONAL INFORMATION ON UNDERGROUND ROOF DRAINS AND

SEE PLAN NOTES SHEET AND DETAIL SHEETS IN THIS PLAN SET FOR

MINIMUM ROOF DRAIN PIPE SLOPE FOR 8" OR LARGER PIPE = 0.50%

MINIMUM ROOF DRAIN PIPE SLOPE FOR 6" PIPE = 1.50%

MATERIAL = SDR 35 PVC

MINIMUM ROOF DRAIN PIPE DIAMETER = 6"

SPILLWAY

EMERGENCY

BOTTOM ELEV = 1486.75

(BMP 1)

PERMANENT MRC BASIN 1

GP

WV

WV CS'S

METER

WATER

METER

WATER

METER

WATER

WV CS

HYDRANT

YARD

MH

MH

INV=1481.80'

TOP OF CO

MH

SAN COSAN CO

PUMP STATION

FAMA SANITARY

I PIN (FND)

WEST MAHANOY TOWNSHIP

RYAN TOWNSHIP

I PIN (FND)

I PIN (FND)

FFE EXHIBIT

PROPOSED GARAGE

ELEV. 1496.30

0.00%

EXHIBIT)

(SEE FFE

3,200 S.F.

GARAGE

PROPOSED

LEVEL

FOOTPRINT

GARGAGE

PROPOSED

NOT TO SCALE

CRADLE

CONCRETE

CRADLE

CONCRETE

X

1495.64 1495.64

X

1495.64

X

FINAL DIMENSIONS AND SLOPES.

APPROXIMATE, SEE ARCHITECTURAL PLANS FOR

NOTE: DIMENSIONS AND SLOPES ARE

X X X

1495.64 1495.64 1495.64

UNDERDRAIN

MRC BASIN

SWALE 1 (BMP 4)

NOT BE DISTURBED

EXISTING WATERLINE TO

NOT TO SCALE

EXHIBIT

DOOR LANDING

PROPOSED SIDEWALK

LANDING

DOOR

PROPOSED

PROPOSED BUILDING FFE 1496.30

X X

X

BOTTOM STEP ELEV 1495.85

TOP STEP ELEV 1496.15

X

BOTTOM STEP ELEV 1495.70

TOP STEP ELEV 1496.15

BOTTOM STEP ELEV 1495.55

TOP STEP ELEV 1496.15

BOTTOM STEP ELEV 1495.64

TOP STEP ELEV 1496.30

EXHIBIT)

(SEE

LANDING

DOOR

X 1489.17

1488.37

XX

1489.17

X

1489.55

X 1484.96

1485.47

1485.14

X

X

X1484.60

(TYPICAL)

RIPRAP APRONS

UNDERGROUND ROOF DRAIN

ELEV=1505.97'

PROPERTY CORNER (FND)

IRON PIN W/ ALUMINUM CAP

BM "B"

ELEV=1482.57'

OF THE CUL-DE-SAC OF FIREMAN'S ROAD

MAGNAIL SET IN PAVE AT THE SOUTH END

BM "A"

BM "A"

BM "B"

FAMA PROJECT)

AS PART OF SEPARATE

(PREVIOUSLY REMOVED

CONNECTION LOCATION WITH FAMA)

(CONTRACTOR TO COORDINATE

PRESSURE SANITARY SEWER MAIN

CONNECT TO FAMA'S LOW

CURB STOP

PROPOSED

STARTING STATION 0+00

SWALE 1 BASE LINE

SWALE 1 BASE LINE

SWALE 2 BASE LINE

STARTING STATION 10+00

SWALE 2 BASE LINE

CLEANOUT (TYP.)

CONCRETE PAD

OUT WITH

PROPOSED CLEAN

CLEANOUT AFTER THE BUILDING AND COVERED PARKING AREA.

REMAINING UNDERGROUND ROOF DRAIN PIPES BEYOND THE FIRST

AND UTILITY PLAN AND THESE NOTES FOR INFORMATION ON ALL

ON THE GRADING AND UTILITY PLAN IN THIS PLAN SET. SEE GRADING

COVERED PARKING AREA FOOTPRINT TO THE FIRST CLEANOUT AS SHOWN

OF PIPES LEAVING THE BUILDING FOOTPRINT AND LEAVING THE

INFORMATION, INCLUDING PIPE DIAMETER, FOR THE FIRST SECTION

SEE PLUMBING PLAN FOR UNDERGROUND ROOF DRAIN PIPE

(APPROXIMATE LOCATION)

FAMA LOW PRESSURE FORCE MAIN

ON SHEET 2)

UTILITY PLAN NOTE 32

(SEE GRADING &

VALVE AND METER

TAPPING SLEEVE, WATER

(12 ON PLAN, ASSUME 8 ADDITIONAL)

BOLLARD (TYPICAL)

MUNICIPAL BOUNDARY

BUILDING SETBACK LINE

LEGAL RIGHT-OF-WAY LINE

BRUSH LINE

EXISTING PROPERTY LINE

EXISTING DRIANAGE PIPE

EXISTING WATER VALVE

EXISTING WATERLINE

EXISTING GUIDERAIL

EXISTING EDGE ROAD / SHOULDER

EXISTING MINOR CONTOUR

EXISTING MAJOR CONTOUR

EXISTING FENCE

Scale: AS NOTED Date: Project No.:

570-622-4055

Pottsville, Pennsylvania 17901

400 One Norwegian Plaza

Alfred Benesch & Company

32008.00 kmarmas 09\02\2026 13:03:07 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\06_Profiles.dgn (Default) reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.

Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, OFKAM KAM KRR 1509/02/2026

West Mahanoy & Ryan Townships, Schuylkill County, Pennsylvania

COUNTY OF SCHUYKILL

FIREMEN'S ASSOCIATION

SCHUYLKILL COUNTY VOLUNTEER

0325-900015.01

INV (OUT )= 1484.48(E)

15101510

15101510

@ 0.64%

15" SLCPP

31.18' OF

@ 1.69%

35.81' OF

15101510

15101510

@ 0.58%

26.70' OF

INV (OUT )= 1484.48(E)

15101510

15101510

OS-2 TO IN1-1OS-1 TO IN1-1 IN3-1 TO EW1

0+00-1+00 1+00-1+00 0+00 1+00 -1+00 0+00 1+00

@ 0.84%

59.76' OF

EXISTING GRADE

PROPOSED GRADE

PROPOSED GRADE

EXISTING GRADE

EXISTING GRADE

PROPOSED GRADE

INV (OUT) = 1486.00 (E)

TG =1491.60

E 2396848.3586 N 529848.9560

INV (OUT) = 1485.60(SE)

INV (IN )= 1485.80(W)

TG =1488.00

E 2396881.4366 N 529851.7822

INV (OUT) = 1484.75(NE)

TG =1488.10

E 2396894.4483 N 529800.6951

INV (OUT) = 1487.25(N)

TG =1491.25

E 2396897.5924 N 529640.0565

INV = 1486.75(N)

E 2396885.6200 N 529699.6275

INV (IN )= 1484.60(NW)

INV (IN )= 1484.60(SW)

TG =1488.60

E 2396911.4128 N 529824.9843

IN1-1 (4'X4' BOX)

BETWEEN PIPES

MINIMUM 18" CLEARANCE

SEWER TO PROVIDE

TO DUCK UNDER STORM

PROPOSED WATER SERVICE

15" RCP

INV (IN )= 1484.60(NW)

INV (IN )= 1484.60(SW)

TG =1488.60

E 2396911.4128 N 529824.9843

IN1-1 (4'X4' BOX)

15" RCP

BETWEEN PIPES

MINIMUM 18" CLEARANCE

STORM SEWER TO PROVIDE

FORCE MAIN TO DUCK UNDER

SERVICE LOW PRESSURE

PROPOSED SANITARY SEWER

15301530

DATUM:

ELEVATION 1490.75

1.45%

2.40%

SWALE 2 PROFILE

15301530

0 1 2 3 4

DATUM:

2.06%

6.

2.15%

ELEVATION 1487.75

SWALE 1 PROFILE

PROPOSED GRADE

EXISTING GRADE

PROPOSED GRADE

EXISTING GRADE

10 11 12 13 14

0 10050 FEET

HORIZONTAL

0 2010 FEET

VERTICAL

STORM SEWER & SWALE PROFILES

I PIN (FND)

W

WVCS

SAN CO

MH

W

NO INFO

W

I PIN (FND)

W \UNDG

PPL 42859-S52961

WVCS

MH

HYDRANT

YARD

WV CS'S

WV

CONTROLS

GATE

I PIN (FND)

WV CS

METER

WATER

METER POLE

NO INFO

S52983

PPL 42849-

SAN CO

SAN CO

0215-PSK6-530

W \UNDG

TOWER

GRAVEL

G R

A V

E L

METER

WATER

METER

WATER

BLDG

BLOCK

BRUSH LINE

CHAINLINK FENCE W/BARBED WIRE

INV=1481.80'

TOP OF CO

MH

OPEN FIELD

(GRASS/STONE)

GARAGE

RYAN TOWNSHIP

WEST MAHANOY TOWNSHIP

F I

R E

M E

N

A D

Sheet No.:Drawn: Designed: Checked:

Rev Date By Chk'd Description

Scale: AS NOTED Date: Project No.:

570-622-4055

Pottsville, Pennsylvania 17901

400 One Norwegian Plaza

Alfred Benesch & Company

32008.00 kmarmas 09\02\2026 13:03:10 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\07_ES Plan.dgn (Default) reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.

Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, OFKAM KAM KRR 1509/02/2026

West Mahanoy & Ryan Townships, Schuylkill County, Pennsylvania

COUNTY OF SCHUYKILL

FIREMEN'S ASSOCIATION

SCHUYLKILL COUNTY VOLUNTEER

0325-900015.01

E&SPC LEGEND

TTS

TP-01 LOCATION & NUMBER

INFILTRATION TEST

STOCKPILE

TEMPORARY TOPSOIL

SOIL TYPE

CONCRETE WASHOUT AREA

CHANNEL/SPILLWAY LINING

EROSION CONTROL BLANKET

ROCK CONSTRUCTION ENTRANCE

INLET PROTECTION

CLEAN OUT STAKE

SKIMMER

ROCK FILTER

COMPOST FILTER SOCK (SIZE AS INDICATED)

PROJECT SITE AREA (NPDES BOUNDARY) (3.10 AC.)

LIMIT OF DISTURBANCE (3.10 AC.)

SOIL BOUNDARY (ENTIRE SITE IS ONE SOIL TYPE)

TEMPORARY CONTOUR

IN0-0

PROPOSED LEGEND

GP

PROPOSED WOODS/BRUSH LINE

PROPOSED RIPRAP

PROPOSED ENDWALL/HEADWALL

PROPOSED STORM INLET & STRUCTURE LABEL

PROPOSED STORM PIPE

PROPOSED GRINDER PUMP

PROPOSED SANITARY FORCE MAIN

PROPOSED SANITARY SEWER LINE

PROPOSED WATER LINE & GATE VALVE

PROPOSED UNDERGROUND ELECTRIC LINE, TELCOM LINE

PROPOSED MINOR CONTOUR

PROP0SED MAJOR CONTOUR

TTS

15"

0 6030 FEET

WV

EXISTING LEGEND

EROSION & SEDIMENTATION CONTROL PLAN

1. SEE PLAN NOTES SHEET IN THIS PLAN SET FOR ALL NOTES.

NOTES:

3,200 S.F.

GARAGE

PROPOSED

BOTTOM ELEV 1485.00

RAIN GARDEN 2 (BMP 5)

BOTTOM ELEV 1490.75

RAIN GARDEN 1 (BMP 3)

PENNSYLVANIA ONE CALL SYSTEM SERIAL NUMBER

20230823233, 20230823234

START OF EXCAVATION.

THAN 10 BUSINESS DAYS PRIOR TO THE

LESS THAN 3 BUSINESS DAYS NOR MORE

DIAL 8-1-1 OR 1-800-242-1776 NOT

WWW.PAONECALL.ORG

COORDINATE YOUR PROJECTS VIA COORDINATE PA AT

P E

N N S Y L V

AN

I

ONE CALL

SYST

E

M

N C

D I

8-

-1

BEFORE

U

D

G

SWALE 2

UNDERGROUND ROOF DRAINS (TYP.)

CLEANOUT (TYP.)

EMERGENCY SPILLWAY

EMERGENCY SPILLWAY

EMERGENCY SPILLWAY

SPILLWAY

EMERGENCY

RCE2

RCE1

CWA1

FILTER BAG

PUMPED WATER

RF2

RF3

X

DP001

X

DP002

GP

BOTTOM ELEV = 1487.75

PERMANENT INFLITRATION BASIN 2 (BMP 2)

TEMPORARY SEDIMENT TRAP 2

RF1

EX-HW1

EX-IN3

EX-IN1

EX-IN2

EX-IN4

PERM. BOTTOM ELEV.: 1486.75

PERMANENT MRC BASIN 1 (BMP 1)

TEMP. BOTTOM ELEV.: 1485.75

TEMPORARY SEDIMENT TRAP 1

TP-01

TP-02

TP-03

TP-04

TP-05

SWALE 1 (BMP 4)

CONCRETE CRADLE

UNDERDRAIN

MRC BASIN

MUNICIPAL BOUNDARY

BUILDING SETBACK LINE

LEGAL RIGHT-OF-WAY LINE

EXISTING WOODS/BRUSH LINE

EXISTING PROPERTY LINE

EXISTING DRIANAGE PIPE

EXISTING WATER VALVE

EXISTING WATERLINE

EXISTING GUIDERAIL

EXISTING EDGE ROAD / SHOULDER

EXISTING MINOR CONTOUR

EXISTING MAJOR CONTOUR

EXISTING FENCE

(TYPICAL)

RIPRAP APRONS

UNDERGROUND ROOF DRAIN

(APPROXIMATE LOCATION)

FAMA LOW PRESSURE FORCE MAIN

10,880 S.F.

FFE 1496.30

BUILDING

PROPOSED

SHEET 2)

NOTE 32 ON

UTILITY PLAN

(SEE GRADING &

METER

WATER VALVE AND

CONTROL PLAN DETAILS

EROSION AND SEDIMENT POLLUTION

EROSION AND SEDIMENTATION CONTROL POLICIES

SEEDING & MULCHING SPECIFICATIONS

NPDES PERMIT NOTES

FILL MATERIALS NOTES AND ENVIRONMENTAL DUE DILIGENCE

CRITICAL STAGES OF BMP IMPLEMENTATION

PREPAREDNESS, PREVENTION AND CONTINGENCY PLANS

AT THE DEPARTMENT'S OR AUTHORIZED COUNTY CONSERVATION DISTRICT'S REQUEST.

IMPLEMENTED FOR EACH IDENTIFIED AREA. THE PPC PLAN SHALL BE MAINTAINED ON SITE AT ALL TIMES AND SHALL BE MADE AVAILABLE FOR REVIEW

ANY TOXIC OR HAZARDOUS SUBSTANCES SUCH AS OIL, GASOLINE, PESTICIDES, HERBICIDES, SOLVENTS, ETC. BMPS SHALL BE DEVELOPED AND

POTENTIAL TO CAUSE NON-COMPLIANCE WITH THE TERMS AND CONDITIONS OF THE NPDES PERMIT DUE TO THE STORAGE, HANDLING OR DISPOSAL OF

STORAGE AREAS, TEMPORARY AND PERMANENT SPOILS STORAGE AREAS, MAINTENANCE AREAS, AND ANY OTHER AREAS THAT MAY HAVE THE

REGULATIONS. THE PPC PLAN SHALL IDENTIFY AREAS WHICH MAY INCLUDE, BUT ARE NOT LIMITED TO, WASTE MANAGEMENT AREAS, RAW MATERIAL

PREPAREDNESS, PREVENTION AND CONTINGENCY (PPC) PLAN. THE PPC PLAN SHALL BE DEVELOPED IN ACCORDANCE WITH APPLICABLE DEP

SAFETY THROUGH ACCIDENTAL RELEASE OF TOXIC, HAZARDOUS, OR OTHER POLLUTING MATERIALS, THE PERMITTEE OR CO-PERMITTEE MUST DEVELOP A

IF THE POTENTIAL EXISTS FOR CAUSING ACCIDENTAL POLLUTION OF AIR, LAND, OR WATER, OR FOR CAUSING ENDANGERMENT OF PUBLIC HEALTH AND

FERTILIZER: 10-10-20 ANALYSIS COMMERCIAL FERTILIZER TO BE APPLIED AT 210 LBS./1,000 SQ. YDS.

LIME: AGRICULTURAL LIME AT 2,480 LBS/1,000 SQ. YDS.

PERMANENT APPLICATION:

FERTILIZER: 10-10-10 ANALYSIS COMMERCIAL FERTERLIZER TO BE APPLIED AT 100 LBS./1,000 SQ. YDS.

LIME: AGRICULTURAL LIME AT 410 LBS/1,000 SQ. YDS.

TEMPORARY APPLICATION:

1. SUPPLEMENTS SHALL CONFORM TO THE REQUIREMENTS OF PADOT PUBLICATION 408, SECTION 804 AND SHALL BE APPLIED DURING THE APPROPRIATE TIMES.

SOIL SUPPLEMENTS:

ACCORDANCE WITH SECTION 805.3.

4. MULCH SHOULD BE ANCHORED IMMEDIATELY AFTER APPLICATION TO PREVENT BEING WINDBLOWN. ANCHOR MULCH WITH SPECIFIED MULCH BINDERS APPLIED IN

SLOPES OF 3:1 OR GREATER, MULCH SHALL BE SECURED THROUGH THE USE OF SPECIFIED NETTING MATERIAL.

3. STRAW MULCH SHALL BE APPLIED AT THE RATE OF 1,200 POUNDS PER 1,000 SQUARE YARDS AND APPLIED WITHIN 48 HOURS OF PLACING SEEDING. ON STEEP

TO BE GRASSED IN THE FUTURE.

2. THE MULCHING SHALL ALSO BE UTILIZED DURING WINTER MONTHS FOR GROUND COVER STABILIZATION ON TOPSOIL STOCKPILES, GRADED SLOPES AND OTHER AREAS

1. MULCHING SHALL CONSIST OF STRAW MULCH AND SHALL MEET THE SPECIFICATIONS AND APPLICATION RATES AS PRESCRIBED IN SECTION 805 OF PUBLICATION 408.

MULCHING:

VEGETATION WITHIN THESE FACILITIES.

3. BOTTOM OF THE SWM / BMP FACILITIES - REFERENCE THE PLANTING SCHEDULE ON THE LAND DEVELOPMENT PLANS FOR THE PLACEMENT OF GRASSES AND

ALL OTHER AREAS - SEE LANDSCAPING PLAN AND BMP SEEDING SCHEDULE FOR SEEDING APPLICATIONS.

LAWN AREAS - FORMULA B SEED MIXTURE WITH A SEEDING APPLICATION RATE OF 42 LBS./1,000 SQ. YDS.

PADOT FOR THE FOLLOWING APPLICATIONS:

2. PERMANENT SEEDING SHALL CONSIST OF PERENNIAL GRASSES (I.E., KENTUCKY BLUEGRASS, FESCUE, PERENNIAL RYE) AND SHALL MEET THE REQUIREMENTS OF

TRANSPORTATION (PADOT) SPECIFICATIONS FOR FORMULA E SEED MIXTURE. THE SEEDING APPLICATION RATE SHALL BE 10 LBS./1,000 SQ. YDS.

1. TEMPORARY SEEDING SHALL CONSIST OF 100 PERCENT ANNUAL RYE GRASS AND SHALL CONFORM TO THE REQUIREMENTS OF THE PA DEPARTMENT OF

SEEDING:

408, LATEST EDITION, SECTIONS 804 AND 805 AND SHALL BE APPLIED DURING THE PRESCRIBED PLANTING PERIOD.

SEEDING, MULCHING AND SOIL SUPPLEMENTS SHALL MEET THE REQUIREMENTS OF THE PA DEPARTMENT OF TRANSPORTATION (PADOT) SPECIFICATIONS, PUBLICATION

MAINTENANCE OF E&S CONTROL DEVICES

PER ACRE PER 1,000 SF PER 1,000 SY NOTESMULCH TYPE

APPLICATION RATE FOR SLOPES LESS THAN 3:1

1 TON

4-6 TONS

3 TONS

3 TONS

415 LB

1,650-2,500 LB

1,240 LB

1,240 LB

MULCH BLANKET

EROSION CONTROL

HYDROMULCH

WOOD CHIPS

HAY

STRAW

SLOPES 3:1 AND GREATER

MANUFACTURERS' INSTRUCTIONS.

APPLY BLANKET AND ANCHOR PER

47 LB

185-275 LB

140 LB

140 LB

MULCH APPLICATION RATES

SC150 (2:1) OR APPROVED EQUALS

NORTH AMERICAN GREEN S150 (3:1) AND

SEE NOTES.

AND LEGUMES

MAY PREVENT GERMINATION OF GRASSES

OTHER NATIVE FORAGE GRASSES

TIMOTHY, MIXED CLOVER AND TIMOTHY OR

WEEDS, NOT CHOPPED OR FINELY BROKEN

EITHER WHEAT OR OAT STRAW, FREE OF

3. THE APPLICATION RATE FOR ANY HYDROMULCH SHOULD BE 2,000 LB/ACRE AT A MINIMUM.

2. WOOD FIBER HYDROMULCH MAY BE APPLIED ON STEEPER SLOPES PROVIDED A TACKIFIER IS USED.

1. SHREDDED PAPER HYDROMULCH SHOULD NOT BE USED ON SLOPES STEEPER THAN 5%.

NOTES:

(NOT) FORM THAT IS SIGNED IN ACCORDANCE WITH PART B.1.C (SIGNATORY REQUIREMENTS) OF THIS PERMIT TO THE COUNTY CONSERVATION DISTRICT.

IN THE POST CONSTRUCTION STORMWATER MANAGEMENT (PCSM) PLAN HAVE BEEN INSTALLED, THE PERMITTEE CO-PERMITTEE OF THE FACILITY MUST SUBMIT A NOTICE OF TERMINATION

NOTICE OF TERMINATION, WHERE ALL STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY THAT ARE AUTHORIZED BY THIS PERMIT ARE ELIMINATED, AND BMP’S IDENTIFIED 4.

ACCEPTABLE NOI, AT LEAST 90 DAYS PRIOR TO THE EXPIRATION DATE OF THE COVERAGE.

PERMITTEE’S REQUESTING RENEWAL OF COVERAGE UNDER GENERAL NPDES PERMIT MUST SUBMIT TO THE COUNTY CONSERVATION DISTRICT AN ADMINISTRATIVELY COMPLETE AND 3.

CONSERVATION DISTRICT, BY PHONE OR PERSONAL CONTACT, FOLLOWED BY THE SUBMISSION OF A WRITTEN REPORT WITHIN 5 DAYS OF THE INITIAL CONTACT.

WHERE E&S BMP’S ARE FOUND TO BE INOPERATIVE OR INEFFECTIVE DURING AN INSPECTION, OR ANY OTHER TIME, THE PERMITTEE SHALL IMMEDIATELY CONTACT THE COUNTY 2.

TREATMENT.

UPON REDUCTION, LOSS OR FAILURE OF THE BMP’S, THE PERMITTEE AND CO-PERMITTEE SHALL TAKE IMMEDIATE ACTION TO RESTORE THE BMP’S OR PROVIDE AN ALTERNATIVE METHOD OF 1.

REGULATIONS ARE AVAILABLE ON-LINE AT WWW.PACODE.COM.

THESE APPLICABLE. IS WHICHEVER MANAGEMENT, WASTE MUNICIPAL 271 OR MANAGEMENT WASTE RESIDUAL 287 CHAPTERS CODE PA. 25 ON BASED REGULATIONS WASTE RESIDUAL

OR MUNICIPAL DEPARTMENT’S THE WITH ACCORDANCE IN MANAGED BE MUST AND WASTE IS FILL REGULATED FILL. REGULATED IS FILL CLEAN AS QUALIFY NOT DOES THAT MATERIAL FILL

DEPARTMENT’S POLICY “MANAGEMENT OF FILL”.

THE OF A APPENDIX WITH ACCORDANCE IN PERFORMED BE SHOULD TESTING FILL. CLEAN AS QUALIFIES IT IF DETERMINE TO TESTED BE MUST IT SUBSTANCE, REGULATED OF RELEASE

OR SPILL…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .