10-260902 Construction Plans.pdf
PDF 8 MB Posted
- Solicitation number
- US.251947
- Issued by
- Somerset County, Pennsylvania
About this file
This is a construction plans document for the Schuylkill County Emergency Training Facility, a project involving the Schuylkill County Volunteer Firemen's Association and municipal authorities across Ryan Township and West Mahanoy Township in Schuylkill County, Pennsylvania. The project, identified as 0325-900015.01, involves the construction of an emergency training facility with multiple plan sheets including site layout, grading and utility plans, erosion and sediment pollution control plans, post-construction stormwater management plans, storm sewer profiles, and construction details. The project encompasses parcel identification numbers 26-06-0016.003 with associated One Call System serial numbers 20230823233 and 20230823234. According to the related contract opportunity, sealed bids for construction are being received through the PennBid Program until October 21, 2026, at 9:00 AM, with a tentative award date of October 28, 2026. The project is being bid as four separate prime contracts: General Construction, Plumbing Construction, HVAC Construction, and Electrical Construction.
Bidders are required to submit a certified check or bank draft in the amount of 10 percent of the total bid as bid security, or an acceptable bid bond naming Schuylkill County as the obligee. The successful bidder must furnish performance and payment bonds in the amount of 100 percent of the contract price with a corporate surety approved by the owner. All bidding documents are available at no cost through PennBid. Davis-Bacon wage rates will apply to this contract. The contractor must comply with non-discrimination requirements regarding race, age, color, religion, sex, national origin, and handicap. Utility coordination is mandatory, requiring notification to the Pennsylvania One Call System at least three and no more than ten business days prior to excavation. The owner reserves the right to waive any informality or reject any or all bids.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Location Map
Cover Sheet1
Drawing Index
Drawing No. Title
N
Rev Date By Chk'd Description
32008.00 kmarmas 09\02\2026 13:02:28 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\01_Cover - Ryan.dgn (Default)
PROJECT
OF1
DRAWING NO.
SCALE IN FEET
1000 1000
PREPARED BY:
PROJECT MANAGER DATE
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
the property of Alfred Benesch & Company. Use, reuse, reproduction or modification of this plan or
Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is
FOR
Erosion & Sediment Pollution Control Plan
Construction Details
All plan sheets to be recorded.
Storm Sewer Profiles
Erosion & Sediment Pollution Control Details
Site Layout Plan
F
IR
E M
E N 'S R
O A
D
L
IA
R
O A
D
INTERSTATE 81
LOCATION
PROJECT
PARCEL IDENTIFICATION
26-06-0016.003
20230823233, 20230823234
EMA FIRE SCHOOL BUILDING
SCHUYLKILL COUNTY VOLUNTEER FIREMEN'S ASSOCIATION
General Notes
14-15
Post Construction Stormwater Management Plan
Post Construction Stormwater Management Plan Details
11-12
PENNSYLVANIA ONE CALL SYSTEM SERIAL NUMBER
START OF EXCAVATION.
THAN 10 BUSINESS DAYS PRIOR TO THE
LESS THAN 3 BUSINESS DAYS NOR MORE
DIAL 8-1-1 OR 1-800-242-1776 NOT
WWW.PAONECALL.ORG
COORDINATE YOUR PROJECTS VIA COORDINATE PA AT
P E
N N S Y L V
ANI
A
ONE CALL SYST
E
M
I
N C
D I
A L
8-1-1 BEFORE
YO
U
D I
G
Grading & Utility Plan
8-10
SCALE: 1" = 1000'
WEST M
AHANOY T
OWNSHIP
RYAN T
OWNSHIP
Existing Conditions & Demolition Plan and Subdivision Plan
LAND DEVELOPMENT PLAN FOR CONSTRUCTION
0325-900015.01
SEPTEMBER 2, 2026
Schuylkill County, Pennsylvania
Ryan Township and West Mahanoy Township
Sheet No.:Drawn: Designed: Checked:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.:
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
32008.00 kmarmas 09\02\2026 13:02:37 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\02_Notes.dgn (Default) reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, OFKAM KAM KRR 1509/02/2026
West Mahanoy & Ryan Townships, Schuylkill County, Pennsylvania
COUNTY OF SCHUYKILL
FIREMEN'S ASSOCIATION
SCHUYLKILL COUNTY VOLUNTEER
0325-900015.01
GENERAL NOTES
ZONING DATA:
WEST MAHANOY TOWNSHIP
RYAN TOWNSHIP
WEST MAHANOY TOWNSHIP:
570-462-1904 office1@mabswater.com
KIARA TAPIA
SHENANDOAH, PA 17967
PO BOX 110
110 N FERGUSON STREET
BOROUGH OF SHENANDOAH
MUNICIPAL AUTHORITY OF THE
610-297-2461 dlhaupt@pplweb.com
DOUG HAUPT
PAXINOS, PA 17860
437 BLUE CHURCH ROAD
PPL ELECTRIC UTILITIES CORPORATION
michael.spaide@amwater.com
MICHAEL SPAIDE
BERWICK, PA 18603
PO BOX 249
306 WEST FRONT STREET
PENNSYLVANIA AMERICAN WATER
570-874-3589 famainfo@fama874.com
RHONDA FRANTZ
FRACKVILLE, PA 17931
42 S CENTER ST
PO BOX 471
FRACKVILLE AREA MUNICIPAL AUTHORITY
570-462-2958
WMTOFFICE@PTO.NET
MICHAEL MICHALIK
SHENANDOAH, PA 17976
190 PENNSYLVANIA AVENUE
WEST MAHANOY TOWNSHIP
570-454-3841 robert.trently@secv.com
ROBERT TRENTLY
HAZLETON, PA 18201
PO BOX R
380 MAPLEWOOD DRIVE
SERVICE ELECTRIC CABLEVISION INC
570-454-5079 timothy.trently@secv.com
TIMOTHY TRENTLY
HAZLETON, PA 18201
PO BOX R
380 MAPLEWOOD DRIVE
SERVICE ELECTRIC CABLEVISION INC
RYAN TOWNSHIP:
570-467-2771
JIM PALAIO
BARNESVILLE, PA 18214
36 N FIFTH AVENUE
RYAN TOWNSHIP
610-297-2461 dlhaupt@pplweb.com
DOUG HAUPT
PAXINOS, PA 17860
437 BLUE CHURCH ROAD
PPL ELECTRIC UTILITIES CORPORATION
570-454-3841 robert.trently@secv.com
ROBERT TRENTLY
HAZLETON, PA 18201
PO BOX R
380 MAPLEWOOD DRIVE
SERVICE ELECTRIC CABLEVISION INC
20230823233 & 20230823234ONE CALL SYSTEM SERIAL NUMBERS:
3/23/2023DATE:
ONE CALL SYSTEM SERIAL NO. NOTIFICATION:
SAID ACT NO. 121 OF 2008.
REFLECTING SAID INFORMATION ON THESE DRAWINGS ONLY DUE TO THE REQUIREMENTS OF THE
ON THESE DRAWINGS IS CORRECT OR ACCURATE, BUT ALFRED BENESCH & COMPANY IS
GUARANTEE THAT THE INFORMATION RECEIVED PURSUANT TO SAID REQUEST AND AS REFLECTED
ALFRED BENESCH & COMPANY DOES NOT MAKE ANY REPRESENTATION, WARRANTY, ASSURANCE OR
IN SECTION 4, CLAUSE (5) OF SAID ACT."
USER'S DESIGNATED OFFICE ADDRESS AND PHONE NUMBER AS SHOWN ON THE LIST REFERRED TO
SYSTEM, THE TOLL-FREE ONE CALL SYSTEM PHONE NUMBER, AND THE NAME OF THE USER, THE
REQUEST MADE AS REQUIRED BY CLAUSE (2), THE SERIAL NUMBER PROVIDED BY THE ONE CALL
UPON THESE DRAWINGS "THE POSITION AND TYPE OF EACH LINE, AS DERIVED PURSUANT TO THE
3. PURSUANT TO SECTION 4, CLAUSE (3) OF SAID ACT, ALFRED BENESCH & COMPANY HAS SHOWN
EXCAVATION IS TO BE PERFORMED.
OBLIGATION OF CLAUSE (2) BY CALLING THE ONE CALL SYSTEM SERVING THE LOCATION WHERE
2. PURSUANT TO SECTION 4, CLAUSE (5) OF SAID ACT, ALFRED BENESCH & COMPANY HAS MET THEIR
THAN (10) NOR MORE THAN (90) WORKING DAYS BEFORE FINAL DESIGN IS TO BE COMPLETED.
NOTIFICATION, THE INFORMATION PRESCRIBED BY SECTION 2, CLAUSE (4) OF SAID ACT, NOT LESS
FROM EACH USER'S OFFICE DESIGNATED ON SUCH LIST PROVIDED BY THE ONE CALL SYSTEM
1. PURSUANT TO SECTION 4, CLAUSE (2) OF SAID ACT, ALFRED BENESCH & COMPANY REQUESTED
POLITICAL SUBDIVISION(S) SHOWN ON THE DRAWINGS:
PREPARING THESE DRAWINGS REQUIRING EXCAVATION OR DEMOLITION WORK AT SITES WITHIN THE
OF 1974, AS AMENDED THE PENNSYLVANIA LEGISLATURE, IT HAS PERFORMED THE FOLLOWING IN
ALFRED BENESCH & COMPANY HERBY STATES THAT , PURSUANT TO THE PROVISIONS OF ACT NO. 287
ACT 287 NOTIFICATION
LIST OF UTILITIES
https://www.pa1call.org/ResourceLibrary/Resource/category/Toolkit
DESIGNER LABEL FROM POCS WEBSITE TOOLKIT
PENNSYLVANIA ONE CALL SYSTEM SERIAL NUMBER
20230823233, 20230823234
START OF EXCAVATION.
THAN 10 BUSINESS DAYS PRIOR TO THE
LESS THAN 3 BUSINESS DAYS NOR MORE
DIAL 8-1-1 OR 1-800-242-1776 NOT
WWW.PAONECALL.ORG
COORDINATE YOUR PROJECTS VIA COORDINATE PA AT
P E
N N S Y L V
ANI
A
ONE CALL SYST
E
M
I
N C
D I
8-1-1 BEFORE
U
D I
G
EXISTING CONDITIONS & DEMOLITION PLAN NOTES
PLAN NOTES
REQUIRED PROVIDED
* INCLUDES PORTION OF PROPERTY IN WEST MAHANOY TOWNSHIP.
<4 STORIES4 STORIES
<70 FEET70 FEET9. MAXIMUM BUILDING HEIGHT:
12.6%30%8. MAXIMUM LAND COVERAGE:
224.9 FEET*50 FEET7. MINIMUM SIDE COMBINED:
108 FEET25 FEET6. MINIMUM SIDE YARD:
109 FEET25 FEET5. MINIMUM REAR YARD:
145 FEET50 FEET4. MINIMUM FRONT YARD:
305 FEET*200 FEET3. MINIMUM LOT WIDTH:
430 FEET200 FEET2. MINIMUM LOT DEPTH:
67,077 SQUARE FEET40,000 SQUARE FEET 1. MINIMUM LOT AREA:
(SERVED BY CENTRAL SEWAGE DISPOSAL)
ZONING DISTRICT: I-2 LIGHT INDUSTRIAL
REQUIRED PROVIDED
* INCLUDES PORTION OF PROPERTY IN RYAN TOWNSHIP.
<35 FEET35 FEET8. MAXIMUM BUILDING HEIGHT:
8.8%60%7. MAXIMUM BUILDING COVERAGE:
224.9 FEET*50 FEET6. MINIMUM SIDE COMBINED:
116.9 FEET25 FEET5. MINIMUM SIDE YARD:
109 FEET25 FEET4. MINIMUM REAR YARD:
145 FEET35 FEET3. MINIMUM FRONT YARD:
305 FEET*75 FEET2. MINIMUM LOT WIDTH:
64,067 SQUARE FEET10,000 SQUARE FEET 1. MINIMUM LOT AREA:
(SERVED BY CENTRAL SEWAGE DISPOSAL)
ZONING DISTRICT: I INDUSTRIAL
PLAN INTENT
CURRENTLY BOTH MAKE UP.
ASSESSMENT PARCELS INSTEAD OF THE SINGLE TAX ASSESSMENT PARCEL THEY
THE PROPOSED LAND DEVELOPMENT, BE SEPARATED INTO TWO SEPARATE TAX
PLAN IS ALSO REQUESTING THAT THE TWO PROPERTIES, ONE OF WHICH WILL CONTAIN
PARKING LOT TO BE USED BY THE COUNTY EMA AND FOR FIRE FIGHTER TRAINING. THIS
THE PURPOSE OF THIS PLAN IS A LAND DEVELOPMENT FOR A PROPOSED BUILDING WITH
SUBDIVISION: TAX ASSESSMENT PARCEL SEPARATION
LINES AS PART OF THIS SUBDIVISION.
ARE SEPARATELY DEEDED PROPERTIES AND THEREFORE THERE ARE NO PROPOSED LOT
SAME OWNERSHIP AS INDICATED IN GENERAL NOTE 7 ON THIS SHEET; HOWEVER, THEY
(26-06-0016.003) INTO TWO SEPARATE TAX PARCELS. BOTH PROPERTIES ARE UNDER THE
PROPERTIES THAT MAKE UP THE SINGLE TAX ASSESSMENT PARCEL NUMBER
THESE PLANS ARE ALSO REQUESTING TO SEPARATE THE TWO SEPARATELY DEEDED
GRADING & UTILITY PLAN NOTES
CONNECTION LOCATION WITH FAMA.
INSTALLED SEPARATELY BY FAMA. CONTRACTOR TO COORDINATE
TO THE LOW PRESSURE SANITARY SEWER MAIN THAT WAS PREVIOUSLY
PROPOSED SANITARY SEWER SERVICE FOR THIS PROJECT IS TO CONNECT
THE EAST SIDE OF FIREMAN'S ROAD AS PART OF A SEPARATE PROJECT.
FAMA ALSO INSTALLED A LOW PRESSURE SANITARY SEWER MAIN ALONG
REMOVAL WAS COMPLETED PRIOR TO COMMENCEMENT OF THIS PROJECT.
SEPARATE PROJECT THAT WAS COMPLETED BY FAMA. THE PUMP STATION
STATION ALONG FIREMEN'S ROAD HAS BEEN REMOVED AS PART OF A
THE EXISTING FRACKVILLE AREA MUNICIPAL AUTHORITY (FAMA) PUMP 17.
RESULT OF THIS PROJECT.
THERE ARE NO NATURAL STEEP SLOPES THAT WILL BE DISTURBED AS A 16.
WOODED AREAS WILL BE DISTURBED AS A RESULT OF THIS PROJECT.
GROWN WITHIN THE AREA OF PROPOSED IMPROVEMENTS. NO EXISTING
REMOVAL WILL BE MINIMAL AND CONSIST OF REMOVAL OF BRUSH THAT HAS
CONSIDERING THE MAJORITY OF THE SITE IS A GRASS AREA, VEGETATION 15.
EACH DAY.
PEDESTRIANS, ETC. CLOSE ALL EXCAVATIONS AND MAKE SAFE AT END OF
PROVIDE MAINTENANCE AND PROTECTION OF TRAFFIC FOR VEHICLES,
CONSTRUCTION. CONTRACTOR TO COORDINATE WITH OWNER AND
COUNTY VOLUNTEER FIREMEN'S ASSOCIATION DURING DEMOLITION AND
THE AREA ADJACENT TO THE SITE MAY BE IN USE BY THE SCHUYLKILL 14.
UTILITY OWNER(S) AND/OR PROVIDER(S).
RELOCATED ACCORDINGLY AND IN COORDINATION WITH CORRESPONDING
RELOCATED OR IMPACTED BY THE PROPOSED IMPROVEMENTS SHALL BE
EXISTING OVERHEAD UTILITY LINES SERVING ANY EXISTING FEATURE BEING 13.
UTILITY POLES AND THE EXTENTION OF ALL PROPOSED UTILITIES.
COMPANY ON THE ADDITION, REMOVAL AND/OR RELOCATION OF UTILITIES,
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE UTILITY 12.
OF ALL UNDERGROUND UTILITIES.
COMPANIES IN ACCORDANCE WITH ACT 287 TO VERIFY AN EXACT LOCATION
THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY
PRIOR TO ANY EARTH MOVING ACTIVITIES ON THE PROPERTY, IT SHALL BE 11.
VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION.
PERFORMED. ALL EXISTING UTILITIES SHOWN HEREON MUST BE FIELD
CALL SYSTEM. NO SUBSURFACE LOCATION OR LOCATION SERVICES WERE
FIELD LOCATIONS AND UTILITIES MARKED IN RESPONSE TO THE PA ONE
UNDERGROUND UTILITIES SHOWN HEREON ARE BASED IN PART ON VISIBLE 10.
UNDERGROUND STRUCTURES.
DETERMINE THE EXISTENCE AND EXACT LOCATION OF ALL UTILITIES AND
BE SHOWN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
AND UNDERGROUND STRUCTURES ARE APPROXIMATE AND MAY NOT ALL
NOTIFY PA ONE CALL AT 1-800-242-1776. THE LOCATION OF ALL UTILITIES
287 - PA ONE CALL NOTIFICATION OF UTILITIES. THE CONTRACTOR SHALL
THE FIELD IN ACCORDANCE WITH ALL APPLICABLE REGULATIONS OF ACT
BEFORE EXCAVATION, ALL UNDERGROUND UTILITIES SHALL BE LOCATED IN 9.
INDICATED OTHERWISE, ALSO SEE NOTE 3.
FEATURES SHOWN IN BOLD INDICATE ITEMS TO BE REMOVED UNLESS 8.
DAMAGED ITEM SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE.
CONDITIONS. IF DAMAGE CANNOT BE REPAIRED ADEQUATELY, THE
PROCESS SHALL BE REPAIRED AND RESTORED TO PRE-DEMOLITION
DAMAGE CAUSED TO EXISTING FEATURES DURING THE DEMOLITION 7.
THE WEATHER SHALL BE STORED IN A SECURE AND DRY LOCATION.
AND SECURE LOCATION. MATERIAL THAT REQUIRES PROTECTION FROM
FROM THE SITE. MATERIALS TO BE REUSED WILL BE STOCKPILED IN A SAFE
UNUSABLE MATERIALS AND RUBBISH SHALL BE IMMEDIATELY REMOVED 6.
CONFORMING MANNER.
UTILITIES WHERE ITEMS ARE BEING REMOVED IN A SAFE AND CODE
THE CONTRACTOR IS RESPONSIBLE FOR TERMINATING ALL APPLICABLE 5.
MARKED TO ENSURE WORKER AND PUBLIC SAFETY.
SHALL BE COVERED OR FENCED OFF, THE AREA SHALL BE ADEQUATELY
EXCAVATIONS THAT ARE LEFT OPEN DURING THE DEMOLITION PROCESS 4.
SHALL BE PROVIDED TO EXISTING FEATURES NOT BEING REMOVED.
THE CONSTRUCTION DOCUMENTS. ADEQUATE AND PROPER PROTECTION
PROPOSED BUILDING AND SITE FEATURES WHETHER OR NOT INDICATED IN
CONTRACTOR TO DEMOLISH ALL ITEMS NECESSARY TO CONSTRUCT THE 3.
CONTRACTOR AND DISPOSED OF AT AN APPROVED FACILITY.
PROJECT SITE MUST BE REMOVED BY A LICENSED HAZARDOUS MATERIAL
ANY EXISTING HAZARDOUS WASTE ENCOUNTERED IN PREPARATION OF THE 2.
RECORD SHALL BE CONTACTED IMMEDIATELY.
DISCREPANCY BETWEEN FIELD AND PLAN CONDITIONS, THE ENGINEER OF
CONTRACTOR PRIOR TO CONSTRUCTION. IN THE EVENT OF ANY
SITE SHALL AND SHOWN ON THIS PLAN SHALL BE FIELD VERIFIED BY
ALL EXISTING CONDITIONS, DIMENSIONS, INVERTS AND ELEVATIONS ON THE 1.
INTERSECTING DRIVEWAY AND STREET.
HEIGHT OF TEN (10) FEET MEASURED FROM THE CENTERLINE GRADES OF THE
WHICH OBSCURES VISION ABOVE THE HEIGHT OF THIRTY (30) INCHES AND BELOW THE
NO VISION OBSTRUCTING OBJECTS ARE PERMITTING WITHIN THE CLEAR SIGHT TRIANGLES 19.
ACCESSES.
BUILDING ACCESS POINTS SHALL BE ADJUSTED IF NECESSARY TO LINE UP WITH BUILDING
EXACT LOCATION OF ACCESS POINTS INTO THE BUILDING. SIDEWALK SECTIONS LEADING TO
SHALL BE CONFIRMED WITH THE ARCHITECTURAL PLANS. SEE ARCHITECTURAL PLANS FOR
THE SIDEWALK SYSTEMS AND ACCESS POINTS INTO THE BUILDING AS SHOWN ON THIS PLAN 18.
JULY 23, 2024. NPDES PERMIT #: PAC-54-0151
BEEN OBTAINED FROM SCHUYLKILL CONSERVATION DISTRICT/PADEP FOR THIS PROJECT ON
EROSION AND SEDIMENT POLLUTION CONTROL PLAN APPROVAL AND NPDES PERMIT HAS 17.
PROJECT SITE OTHER THAN THE POND AS SHOWN PARCEL 2.
WETLAND INVENTORY WEBSITE, THERE ARE NO WELTANDS OR WATERCOURSES ON THE
BASED ON THE WETLANDS MAPPER ON THE U.S. FISH AND WILDLIFE SERVICE - NATIONAL
A WETLAND AND WATERCOURSE DETERMINATION WAS NOT PERFORMED FOR THE SITE. 16.
AT AN APPROVED FACILITY.
MUST BE REMOVED BY A LICENSED HAZARDOUS MATERIAL CONTRACTOR AND DISPOSED OF
ANY EXISTING HAZARDOUS WASTE ENCOUNTERED IN PREPARATION OF THE PROJECT SITE 15.
ALL TRENCHING TO BE IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL LAWS.14.
WATER.
THIS DEVELOPMENT WILL BE SERVED BY PENNSYLVANIA AMERICAN WATER FOR PUBLIC 13.
PUBLIC SEWER.
THIS DEVELOPMENT WILL BE SERVED BY FRACKVILLE AREA MUNICIPAL AUTHORITY FOR 12.
AND OBTAIN ANY REQUIRED SIGN PERMIT PRIOR TO SIGN CONSTRUCTION.
ORDINANCE, DEPENDING ON THE MUNICIPALITY THE SIGN IS PROPOSED TO BE PLACED IN,
OF THE WEST MAHANOY TOWNSHIP ZONING ORDINANCE OR THE RYAN TOWNSHIP ZONING
ANY PROPOSED BUILDING OR SITE SIGN SHALL BE SUBJECT TO THE SIGN REQUIREMENTS 11.
PROVIDED AT THE TIME OF BUILDING PERMIT APPLICATION(S).
THE LAND DEVELOPMENT APPROVAL PURPOSES ONLY. ARCHITECTURAL PLANS SHALL BE
BUILDING DIMENSIONS AND COVERED PARKING AREA SHOWN ON THIS PLAN SET ARE FOR 10.
STRUCTURES. ALL ANGLES ARE 90 DEGREES UNLESS OTHERWISE NOTED.
UNLESS NOTED. ALL BUILDING DIMENSIONS ARE REFERENCED TO THE OUTSIDE FACE OF
ALL SITE DIMENSIONS ARE REFERENCED TO THE FACE OF CURB OR EDGE OF PAVING 9.
VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION ACTIVITIES.
ALL DIMENSIONS, ELEVATIONS, AND INVERTS SHOWN IN THIS PLAN SHALL BE FIELD 8.
PARCEL ACREAGE: 23.963 ACRES (1,043,826.47 SF)
UPI NO. 26-06-0016.003
DEED BOOK 1377, PAGE 112
PARCEL 2:
PARCEL ACREAGE: 3.011 ACRES (131,150.00 SF)
UPI NO. 26-06-0016.003
DEED BOOK 687, PAGE 64
PARCEL 1:
POTTSVILLE, PA 17901
P.O. BOX 535
SCHUYLKILL COUNTY VOLUNTEER FIREMEN'S ASSOCIATION
RECORD OWNER & SOURCE OF TITLE:7.
TO FEMA FIRM MAP NUMBER 42107C0164F, WITH EFFECTIVE DATE MAY 18, 2021.
THE PROPOSED SITE IS NOT LOCATED WITHIN A MAPPED 100-YEAR FLOODPLAIN ACCORDING 6.
OF 1988 (NAVD-88).
(SOUTH ZONE) NAD-83. VERTICAL DATUM IS BASED ON NORTH AMERICAN VERTICAL DATUM
HORIZONTAL DATUM IS BASED ON THE PENNSYLVANIA STATE PLANE COORDINATE SYSTEM 5.
SHOWN ARE TAKEN FROM CURRENT AVAILABLE PASDA LiDAR INFORMATION.
BASED ON A FIELD SURVEY PERFORMED BY BENESCH IN APRIL 2023. ALL OTHER CONTOURS
CONTOUR LINES IN THE AREA OF PROPOSED IMPROVEMENTS DEPICTED ON THIS PLAN ARE 4.
MERIDIAN.
RESTRICTION NOT SHOWN HEREON. BOUNDARY LINE BEARINGS ARE BASED ON DEED
PROPERTIES SHOWN HEREON MAY BE SUBJECT TO EASEMENTS, RIGHT-OF-WAYS AND
THE BOUNDARY SURVEY WAS DONE WITHOUT THE BENEFIT OF A TITLE SEARCH AND THE 3.
PERFORMED BY BENESCH IN APRIL 2023.
BOUNDARY AND EXISTING FEATURES SHOWN ON THIS PLAN ARE BASED ON A FIELD SURVEY 2.
PARKING LOT TO BE USED BY THE COUNTY EMA AND FOR FIRE FIGHTER TRAINING.
THE PURPOSE OF THIS PLAN IS A LAND DEVELOPMENT FOR A PROPOSED BUILDING WITH 1.
AFTER THE BUILDING AND COVERED PARKING AREA.
THESE NOTES FOR INFORMATION ON ALL REMAINING UNDERGROUND ROOF DRAIN PIPES BEYOND THE FIRST CLEANOUT FIRST CLEANOUT AS SHOWN ON THE GRADING AND UTILITY PLAN IN THIS PLAN SET. SEE GRADING AND UTILITY PLAN AND SECTION OF PIPES LEAVING THE BUILDING FOOTPRINT AND LEAVING THE COVERED PARKING AREA FOOTPRINT TO THE SEE PLUMBING PLAN FOR UNDERGROUND ROOF DRAIN PIPE INFORMATION, INCLUDING PIPE DIAMETER, FOR THE FIRST 33.
REQUEST THE SERVICE APPLICATION PACKAGE.
COMPELTED AND SUBMITTED BY CONTRACTOR TO PAW. OWNER/ARCHITECT TO CONTACT PAW (1-800-565-7292) TO PENNSYLVANIA AMERICAN WATER (PAW) TO SIZE THE TAP AND METER AFTER PAW SERVICE APPLICATION PACKAGE IS 32.
ELECTRIC POWER TO THE PROPOSED GRINDER PUMP IS THE RESPONSIBILITY OF THE CONTRACTOR.31.
BEYOND THE RIGHT-OF-WAY OF FIREMENS ROAD.
ROAD TO AT LEAST 20 FEET BEYOND THE RIGHT-OF-WAY OF FIREMENS ROAD, AND SHALL NOT EXCEED 10% SLOPE PROPOSED GRADING ALONG ACCESS DRIVES SHALL NOT EXCEED 5% SLOPE FROM THE INTERSECTION WITH FIREMENS 30.
MOUNDED TOWARDS THE CENTER OF THE ISLAND.
PARKING LOT ISLAND AREAS INDICATED TO BE RIVER ROCK SHALL BE FLUSH WITH EDGE OF PAVING AND SLIGHTLY 29.
PLUMBING PLAN.
PROPOSED SEWER AND WATER SERVICE SIZES AND DETAILS TO BE DESIGNED SEPARATELY AND PROVIDED ON THE 28.
PART OF SEPARATE PROJECT BY FAMA. CONTRACTOR TO COORDINATE WITH FAMA AT TIME OF CONNECTION.
PRESSURE SEWER MAIN LOCATED ALONG THE EAST SIDE OF FIREMEN'S ROAD, WHICH WAS PEVIOUSLY INSTALLED AS SANITARY SEWER SERVICE FOR THIS PROJECT TO CONNECT TO FRACKVILLE AREA MUNICIPAL AUTHORITY'S (FAMA) LOW 27.
LEAST 6" BEYOND THE CLEANOUT PIPE WALL IN ALL DIRECTIONS.
PSI CONCRETE PAD, 6" THICK, SHALL BE PLACED AT THE SURFACE AROUND THE CLEANOUT AND SHALL EXTEND AT SURFACE TO PREVENT A TRIPPING HAZARD. IF CLEANOUT CAP IS INSTALLED WITHIN A DRIVING SURFACE, A SQUARE 3,500 PVC CAP. IF CLEANOUT IS WITHIN A WALKING OR DRIVING SURFACE, CAP SHALL BE INSTALLED TO BE FLUSH WITH TO MATCH DIAMETER OF ACTUAL UNDERGROUND ROOF DRAIN PIPE. CLEANOUT SHALL BE CAPPED WITH A SCREW ON UNDERGROUND ROOF DRAIN PIPE WITH A PVC PIPE TEE CONNECTION. NOTE: DIAMETER OF CLEANOUT DOES NOT NEED UNDERGROUND ROOF DRAIN CLEANOUTS TO BE MINIMUM DIAMETER 4" SDR 35 PVC PIPE CONNECTED TO THE 26.
COMPLY WITH ALL APPLICABLE SAFETY REQUIREMENTS.
CONTRACTOR TO COORDINATE PROPOSED GATES WITH OWNER AND REFER TO ARCHITECTURAL PLANS. GATES SHALL 25.
COUNTY SCREENING AND SEPARATION REQUIREMENTS.
REQUIREMENTS, EQUIPMENT DETAILS AND PROTECTION AS NECESSARY, AND COMPLY WITH ANY MUNICIPAL AND/OR ARCHITECT TO COORDINATE WITH LOCAL GAS PROVIDERS TO DETERMINE TANK SIZE AND LOCATION, TANK PUBLIC GAS SERVICE IS NOT AVAILABLE FOR THIS PROJECT SITE. CONTRACTOR ALONG WITH DEVELOPER AND 24.
BUILDING.
APPROVAL BY, THE RESPECTIVE UTILITY SUPPLIERS. IT IS SHOWN AS AN UNDERGROUND SERVICE TO THE PROPOSED THE ELECTRICAL SERVICE LINES SHOWN ON THE PLANS ARE PRELIMINARY AND WILL REQUIRE COORDINATION WITH, AND 23.
ALL PROPOSED SLOPES SHALL BE 2:1 (HORIZONTAL:VERTICAL) MAXIMUM UNLESS OTHERWISE NOTED.22.
UNLESS OTHERWISE NOTED.
BE STRIPPED AND REMOVED FROM NEW CONSTRUCTION AREAS AND PROPERLY DISPOSED OF AT AN APPROVED SITE ALL EXISTING TREES, VEGETATION, PAVEMENTS, CONCRETE FOUNDATIONS, STRUCTURES AND ORGANIC TOPSOIL SHALL 21.
ADVANCED DRAINAGE SYSTEMS (ADS) OR APPROVED EQUAL, UNLESS OTHERWISE NOTED.
ALL STORM PIPING SHALL BE SMOOTH LINED CORRUGATED POLYETHYLENE PIPE (SLCPP) AS MANUFACTURED BY 20.
ALL ENDWALLS SHALL BE PRECAST CONCRETE TYPE DW ENDWALLS.19.
ALL INLETS OVER 5 FEET IN DEPTH SHALL BE PROVIDED WITH MANHOLE STEPS.18.
SPECIFIED.
ALL INLETS SHALL BE PADOT TYPE M INLETS WITH STRUCTURAL STEEL (BICYCLE SAFE) GRATES UNLESS OTHERWISE 17.
CONTRACTOR IN THE FIELD AND COORDINATED WITH FAMA.
INSTALLED AS PART OF A SEPARATE PROJECT. THIS CONNECTION IS APPROXIMATE AND SHALL BE VERIFIED BY DEPICTING PROPOSED FRACKVILLE AREA MUNICIPAL AUTHORITY (FAMA) SEWER UPGRADES THAT WERE PREVIOUSLY LOCATION OF PROPOSED SANITARY SERVICE CONNECTION TO EXISTING MAIN IS APPROXIMATE AND BASED ON PLANS 16.
WHERE THEY ENTER THE BUILDING.
GAS LINES, AND ELECTRIC CONNECTIONS TO THE PROPOSED BUILDING, INCLUDING SIZE OF LINES AND LOCATIONS SEE ARCHITECTURAL AND/OR PLUMBING PLANS FOR INFORMATION ON SANITARY SEWER LATERAL, WATER SERVICE LINE, 15.
INSPECTION, TESTING AND FINAL ACCEPTANCE OF ALL PROPOSED UTILITIES CONSTRUCTED.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FEES ASSOCIATED WITH THE CONNECTION, INSTALLATION, 14.
APPLICABLE LOCAL AND STATE CODES AND REGULATIONS.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BID AND PERFORM ALL UTILITY WORK IN COMPLIANCE TO ALL 13.
WATER.
AND REGULATIONS OF BOTH RYAN TOWNSHIP AND WEST MAHANOY TOWNSHIP, COUNTY, AND PENNSYLVANIA AMERICAN WITH PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION SPECIFICATIONS, AND ALL ORDINANCES, RULES, ALL WATER SUPPLY AND DISTRIBUTION SYSTEMS, PUBLIC OR ON-SITE SHALL BE CONSTRUCTED IN FULL COMPLIANCE 12.
WHETHER PERFORMED BY THE CONTRACTOR OR NOT.
OF THE CONTRACTOR TO ENSURE ALL UTILITIES ARE INSTALLED CORRECTLY TO MEET PROJECT REQUIREMENTS STANDARD SPECIFICATIONS AND PER ALL APPLICABLE PADEP REQUIRMENTS AND STANDARDS. IT IS THE RESPONSIBILITY SANITARY SEWER SPECIFICATIONS SHALL BE IN ACCORDANCE WITH THE FRACKVILLE AREA MUNICIPAL AUTHORITY ALL UTILITIES SHALL BE INSTALLED IN ACCORDANCE WITH THE SPECIFICATIONS OF THE RESPECTIVE UTILITY COMPANY. 11.
NOTED IN THE CONSTRUCTION DRAWINGS, SITE SPECIFICATIONS OR INSTRUCTED BY THE OWNER.
ALL AREAS NOT PAVED OR CONCRETE SHALL BE TOPSOILED, SEEDED, MULCHED OR LANDSCAPED UNLESS OTHERWISE 10.
RELOCATION OF UTILITIES, UTILITY POLES AND THE EXTENTION OF ALL PROPOSED UTILITIES.
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE UTILITY COMPANY ON THE ADDITION, REMOVAL AND/OR 9.
LOCATION OF ALL UTILITIES AND UNDERGROUND STRUCTURES.
MAY NOT ALL BE SHOWN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXISTENCE AND EXACT ONE CALL AT 1-800-242-1776. THE LOCATION OF ALL UTILITIES AND UNDERGROUND STRUCTURES ARE APPROXIMATE AND APPLICABLE REGULATIONS OF ACT 287 - PA ONE CALL NOTIFICATION OF UTILITIES. THE CONTRACTOR SHALL NOTIFY PA BEFORE EXCAVATION, ALL UNDERGROUND UTILITIES SHALL BE LOCATED IN THE FIELD IN ACCORDANCE WITH ALL 8.
LAWS.
CONSTRUCTION STANDARDS (RC STANDARDS), CURRENT EDITIONS, AND ALL OTHER PERTINENT FEDERAL AND STATE SCHUYLKILL COUNTY, AND IN ACCORDANCE WITH PADOT SPECIFICATIONS, PUBLICATION 408 AND THE ROADWAY MAHANOY TOWNSHIP, THE CURRENT REQUIREMENTSM OF RYAN TOWNSHIP, THE CURRENT REQUIREMENTS OF ALL SITE WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS, THE CURRENT REQUIREMENTS OF WEST 7.
FOR THE OWNER'S AND ENGINEERS'S REVIEW PRIOR TO CONSTRUCTION.
FOR ANY ITEMS NOT COVERED BY DETAILS OR SPECIFICATIONS, THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS 6.
CONSTRUCTION EASEMENTS.
NO WORK SHALL OCCUR OUTSIDE OF THE PROPERTY OR RIGHT-OF-WAY LINES UNLESS COVERED BY GRADING OR 5.
NOTED.
ALL SPOT ELEVATIONS ARE REFERENCED TO THE FINISHED PAVEMENT OR GROUND SURFACE UNLESS OTHERWISE 4.
TIE INTO EXISTING GRADES NO CLOSER THAN 3 FEET FROM ANY PROPERTY LINE UNLESS OTHERWISE AUTHORIZED.
FINISHED EARTHEN SLOPES SHALL BE ROUNDED TO PROVIDE A UNIFORM AND AESTHETIC LANDSCAPE. GRADING SHALL ALL FINAL SITE GRADING SHALL BE SMOOTH AND EVEN AND WITHOUT ABRUPT BREAKS OR CHANGES IN GRADE. 3.
INCLUDING STEPS AND LANDINGS, AND UTILITY SERVICE POINTS.
COORDINATION WITH FINAL BUILDING DESIGN IS REQUIRED TO CONFIRM BUILDING DIMENSIONS, ACCESS LOCATIONS 2.
CONDITIONS, THE ENGINEER OF RECORD SHALL BE CONTACTED IMMEDIATELY.
VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. IN THE EVENT OF ANY DISCREPANCY BETWEEN FIELD AND PLAN ALL EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS ON THE SITE AND SHOWN ON THIS PLAN SHALL BE FIELD 1.
Scale: AS NOTED Date: Project No.:
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
32008.00 kmarmas 09\02\2026 13:02:50 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\03_Ex_Condition.dgn (Default) reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, OFKAM KAM KRR 1509/02/2026
West Mahanoy & Ryan Townships, Schuylkill County, Pennsylvania
COUNTY OF SCHUYKILL
FIREMEN'S ASSOCIATION
SCHUYLKILL COUNTY VOLUNTEER
0325-900015.01
WVCS
W
WVCS
W
W
WVCS
POND
POND
BM
"B"
BM
"A"
0 200100 FEET
SR 0
(S
OUTHBOUND)
SR 00
81 (
N0RTHBOUND)
1. SEE PLAN NOTES SHEET IN THIS PLAN SET FOR ALL NOTES.
NOTES:
F I
R E
M E
N S
R O
A D
RI
GHT-
OF-
WAY
WI
DE
UPI #26-06-0017.900
AND LIGHT COMPANY
N/F PENNSYLVANIA POWER
UPI #26-06-0016.000
DEVELOPMENT CORPORATION
N/F SCHUYLKILL ECON0MIC
CHAI
NLI
NK
FENCE
W/
BARBED
WI
RE
BRUSH
LI
NE
RESTROOMS
BRI
CK
BLDG
BLDGFRAME
BLDGBLOCK
GRAVEL
CONTROLS
GATE
PPL
9-
S5
UPI #26-06-0018.000
N/F JMB LTD
UPI #36-06-0006.000
N/F GPIDC
UPI #36-06-0006.012
N/F MARIANNE M. MCANDREW
-P
SK6
-5
30W
\UNDG
WEST
MAHANOY
TOWNSHI
P
RYAN
TOWNSHI
P
I
PI
N (F
ND)
I
PI
N (F
ND)
I
PI
N (F
ND)
I
PI
N (F
ND)
METER
POLE
NO
INFO
I
PI
N (F
ND)
WV
EXISTING LEGEND
S
E
ARC-1
,06
0.3 6'
TAN-5
31.
07'RAD-7
,47
8.4 9'
-88.40
BLDGBLOCK
BLDGBLOCK2
STORY
CONCRETE
PAD
PAVI
LI
ON
CONCRETE P
AD
BUILDINGBLOCK
SHED
GARAGE
4 STALL BLDG
CONC
3 STORY
BLDG
PAD
CONCRETE
EXISTING CONDITIONS & DEMOLITION PLAN
CHAINLINK FENCE W/BARBED WIRE
(PARCEL 1)
3.011 ACRES
UPI #26-06-0016.003
BK 0687 PG 0064
FIREMEN'S ASSOCATION
SCHUYLKILL COUNTY
(PARCEL 2)
23.963 ACRES
UPI #26-06-0016.003
BK 1377 PG 0112
FIREMEN'S ASSOCATION
SCHUYLKILL COUNTY
BRUSH
CARTWAY
(TBR)
TBR TO BE REMOVED
MUNICIPAL BOUNDARY
BUILDING SETBACK LINE
LEGAL RIGHT-OF-WAY LINE
EXISTING WOODS/BRUSH LINE
EXISTING WETLANDS
EXISTING STREAMS/EDGE OF WATER
EXISTING PROPERTY LINE
EXISTING DRIANAGE PIPE
EXISTING WATER VALVE
EXISTING WATERLINE
EXISTING GUIDERAIL
EXISTING EDGE ROAD / SHOULDER
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
EXISTING FENCE
FOR L
IMITED ACCESS
LEGAL R
IGHT-OF-WAY L
INE
FOR LIMITED ACCESS
LEGAL RIGHT-OF-WAY LINE
WEST
MAHANOY
TOWNSHI
P
RYAN
TOWNSHI
P
UPI #26-06-0019.000
N/F JMB LTD
(FENCE ALONG FIREMEN'S ROAD TBR)
EXISTING STORM SEWER INFORMATION
EX-
IN1
EX-
IN2
EX-
IN3
EX-
HW1
INVERT=1484.48'
15" RCP
EX-HW1
15" CMP
INVERT (E)=1480.94'
TOP=1483.14'
INLET=4 X 2.2
EX-IN4
30" RCP
INVERT (S)=1479.11'
30" CPP
INVERT (N)=1479.11'
15" RCP
INVERT (W)=1482.81'
TOP=1487.81'
INLET=4 X 2.2
EX-IN3
15" CPP
INVERT (E)=1491.68'
30" CPP
INVERT (N)=1480.50'
30" CPP
INVERT (S)=1480.50'
TOP=1492.70'
INLET=4 X 2.2
EX-IN2
12" CPP
INVERT (N)=1481.26'
15" CPP
INVERT (W)=1481.25'
TOP=1484.39'
INLET=4 X 2.2
EX-IN1
EX-
IN4
METERWATER
METERWATER
PUMP
STATI
ON
FAMA
SANI
TARY
WATER
METER
VALVE
YARD
HYDRANT WV(
3)
PPL
9-
S5
GARAGE
CHANNEL
EXI
STI
NG
CHANNEL
EXI
STI
NG
SUBDIVISION: TAX ASSESSMENT PARCEL SEPARATION
AND SUBDIVISION PLAN
TAX PARCELS
TO CREATE SEPARATE
EXISTING DEED LINE
ALONG THE EXISTING DEED LINE AS SHOWN ON THIS PLAN.
LOT LINES AS PART OF THIS SUBDIVISION. THE TAX PARCEL SEPARATION WILL BE
THEY ARE SEPARATELY DEEDED PROPERTIES AND THEREFORE THERE ARE NO PROPOSED
THE SAME OWNERSHIP AS INDICATED IN GENERAL NOTE 7 ON THIS SHEET; HOWEVER,
(26-06-0016.003) INTO TWO SEPARATE TAX PARCELS. BOTH PROPERTIES ARE UNDER
PROPERTIES THAT MAKE UP THE SINGLE TAX ASSESSMENT PARCEL NUMBER
THESE PLANS ARE ALSO REQUESTING TO SEPARATE THE TWO SEPARATELY DEEDED
ELEV=1505.97'
PROPERTY CORNER (FND)
IRON PIN W/ ALUMINUM CAP
BM "B"
ELEV=1482.57'
OF THE CUL-DE-SAC OF FIREMAN'S ROAD
MAGNAIL SET IN PAVE AT THE SOUTH END
BM "A"
CHAINLINK FENCE W/BARBED WIRE
(FENCE ALONG NORTHERN PERIMETER TO BE REPLACED)
CHAINLINK FENCE W/BARBED WIRE
(FENCE ALONG WESTRERN PERIMETER TO BE REPLACED)
BY
FAMA)PROJ
ECT
COMPLETED
OF
SEPARATE
(REMOVED
AS
PART
(APPROXI
MATE
LOCATI
ON)
FAMA
LOW
PRESSURE
FORCE
MAI
N
BxB
W
UM
W
HGC
BxB
HGB
UM
UM
UM
I PIN (FND)
WVCS
W
WVCS
SAN CO
MH
W
NO INFO
W
I PIN (FND)
W \UNDG
PPL 42859-S52961
WVCS
MH
HYDRANT
YARD
WV CS'S
WV
CONTROLS
GATE
I PIN (FND)
WV CS
METER
WATER
METER POLE
NO INFO
S52983
PPL 42849-
SAN CO
SAN CO
0215-PSK6-530
W \UNDG
TOWER
GRAVEL
G R
A V
E L
WATER
METER
METER
WATER
CHAINLINK FENCE W/BARBED WIRE
INV=1481.80'
TOP OF CO
MH
GARAGE
RYAN TOWNSHIP
WEST MAHANOY TOWNSHIP
F I
R E
M E
N
A D
Sheet No.:Drawn: Designed: Checked:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.:
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
32008.00 kmarmas 09\02\2026 13:03:04 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\04_Pr_Site.dgn (Default) reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, OFKAM KAM KRR 1509/02/2026
West Mahanoy & Ryan Townships, Schuylkill County, Pennsylvania
COUNTY OF SCHUYKILL
FIREMEN'S ASSOCIATION
SCHUYLKILL COUNTY VOLUNTEER
0325-900015.01
0 6030 FEET
SITE LAYOUT PLAN
WV
3,200 S.F.
GARAGE
PROPOSED
176'
40'136'
300'
290'
(TYP)
20'
T
Y P
(TYP)
10'
(TYP)
5'
T
Y P
12'
R=5' R=2'R=5'
R=2'
R=2'
R=5'
13'
R=2' R=5'
R=20'
R=5'
R=10'
R=10'
10 9
9 10 10
18 12
29'
24'
24'
24'
104'
98'20'
20'
88'
(TYP)
R=5'
29'35'
34'
(TYP)
R=5'
R=20'
R=10'
R=10'
R=10'
22'
'9
4'
(TYP)
5'
22'
22'
R=5'
10,880 S.F.
BUILDING
PROPOSED
GATE
GATE
(TYP)
R=2'
(TYP)
R=2'
25'
25' 50'
35'
BUILDING SETBACK LINE (TYP)
(TYP)
R=2' R=2'
TOTAL PROPOSED PARKING SPACES = 116 SPACES
TOTAL REQUIRED BY WEST MAHANOY TOWNSHIP ZONING ORDINACE = 41 SPACES
(3 TRAINING ROOMS WITH 45 OCCUPANTS PER ROOM = 135 SEATS /17 = 8 SPACES
TRAINING SCHOOL (1 SPACE FOR EACH 17 CLASSROOM SEATS):
(10,880 SF (DOES NOT INCLUDE GARAGE)/1,000 = 10.88 X 3 = 32.64 SPACES
OFFICES (3 SPACES FOR EACH 1,000 SF OF FLOOR AREA):
REQUIRED FOR ENTIRE SITE:
PARKING ANALYSIS - WEST MAHANOY TOWNSHIP
PARKING ANALYSIS - RYAN TOWNSHIP
TOTAL PROPOSED PARKING SPACES = 116 SPACES
TOTAL REQUIRED BY RYAN TOWNSHIP ZONING ORDIANCE = 64 SPACES
(3 TRAINING ROOMS WITH 45 OCCUPANTS PER ROOM = 135 SEATS/5 = 27 SPACES
TRAINING SCHOOL (1 SPACE FOR EACH 5 CLASSROOM SEATS)
(10,880 SF (DOES NOT INCLUDE GARAGE)/300 = 36.27 SPACES
OFFICES (1 SPACE FOR EACH 300 SF OF FLOOR AREA
REQUIRED BY ENTIRE SITE:
ADA PARKING SPACE ANALYSIS
ADA SPACES PROPOSED = 6 SPACES
ADA SPACES REQUIRED = 5 SPACES
11'
ACCESSIBLE
VAN
ACCESSIBLE
VAN
11'
(SEE DETAIL)
ADA SIGNAGE (TYP)
BUMPER (TYP)
CONCRETE CAR
GATE
GATE
LEGEND
30" X 30"
STOP SIGN
30" X 30"
STOP SIGN
DWS DWS
DWS DWS
DWS
DWS
LANDING
DOOR
VERTICAL CURB
ISLAND WITH
PROPOSED CONCRETE
VERTICAL CURB
ISLAND WITH
PROPOSED CONCRETE
TRIANGLE
40' CLEAR SIGHT
TRIANGLE
40' CLEAR SIGHT
ASSUMED SPEED LIMIT 35 MPH
SPEED LIMIT NOT POSTED
ASSUMED SPEED LIMIT 35 MPH
SPEED LIMIT NOT POSTED
PROVIDED SIGHT DISTANCE = 360'
DISTANCE TABLE
BASED ON PENNDOT FORMULA SIGHT
REQUIRED SIGHT DISTANCE = 286'
PROVIDED SIGHT DISTANCE = 510'
DISTANCE TABLE
BASED ON PENNDOT FORMULA SIGHT
REQUIRED SIGHT DISTANCE = 275'
PAINT LINES
4" YELLOW
PAINT LINES
4" YELLOW
10'
6'
PARKING)(TYP)
(NON ADA
PAINT LINES
4" YELLOW
PAINT LINES
4" YELLOW
PAINT LINES
4" YELLOW
LINES
PAINT
4" BLUE
ENTRANCE
LENGTH OF THE ROAD TO THE GATED
DISTANCE EXTENDS TO THE REMAINING
PROVIDED SIGHT DISTANCE = SIGHT
ENDS AT SOUTHERN END OF SITE.
REQUIRED SIGHT DISTANCE = N/A - ROAD
ENTRANCE
LENGTH OF THE ROAD TO THE GATED
DISTANCE EXTENDS TO THE REMAINING
PROVIDED SIGHT DISTANCE = SIGHT
ENDS AT SOUTHERN END OF SITE.
REQUIRED SIGHT DISTANCE = N/A - ROAD
ELEV=1505.97'
PROPERTY CORNER (FND)
IRON PIN W/ ALUMINUM CAP
BM "B"
ELEV=1482.57'
OF THE CUL-DE-SAC OF FIREMAN'S ROAD
MAGNAIL SET IN PAVE AT THE SOUTH END
BM "A"
BM "A"
BM "B"
(TYP.)
LEGENDS
PAINT
ARROW
WHITE 11
COORDINATES
POINT NORTHING EASTING
LOCATION AND HEIGHT)
(MATCH EXISTING FENCE TYPE,
REPLACE ALL EXISTING FENCE
PROPOSED FENCE REPLACEMENT
COORDINATE POINT LOCATION
PROPOSED DETECTABLE WARNING SURFACE
PROPOSED PARKING SPACE COUNT
PROPOSED RIVER ROCK
PROPOSED CONCRETE
PROPOSED PAVING
MUNICIPAL BOUNDARY
BUILDING SETBACK LINE
LEGAL RIGHT-OF-WAY LINE
EXISTING WOODS/BRUSH LINE
EXISTING WETLANDS
EXISTING STREAMS / EDGE OF WATER
EXISTING PROPERTY LINE
EXISTING DRIANAGE PIPE
EXISTING WATER VALVE
EXISTING WATERLINE
EXISTING GUIDERAIL
EXISTING EDGE ROAD / SHOULDER
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
EXISTING FENCE
ALL 11.5' IN WIDTH
6 COVERED PARKING SPACES
LINES
PAINT
4" BLUE
LATERAL CLEANOUT
PAD FOR SANITARY
PROPOSED CONCRETE
529679.2810
529682.7166
529825.7181
529598.8469
529591.2871
529596.1043
529616.3295
529642.3165
529649.3393
529663.5447
529691.9722
529690.9267
529757.2188
529767.7345
529756.5142
529770.7197
529769.8607
529712.4905
529721.9772
529728.0790
529709.1384
529683.3041
529759.0636
529626.7854
529702.5449
529556.6104
529540.3046
529587.8599
529570.8134
529621.5802
529604.5337
529633.4368
529653.9831
529680.4915
529703.2001
529676.9360
529819.9375
529799.5538
529823.5935
529846.3970
529824.5305
529850.6770
529801.5159
529818.5624
529767.7956
529784.8421
529727.0757
529754.3333
2396880.3272
2396934.0526
2396885.5596
2396615.1097
2396620.8411
2396635.0466
2396632.4118
2396765.0944
2396776.4626
2396771.6454
2396827.4507
2396808.7984
2396786.3182
2396801.7590
2396740.6466
2396735.8294
2396723.9549
2396576.5723
2396576.5230
2396594.5166
2396600.9395
2396801.8782
2396776.1892
2396635.1982
2396609.5093
2396580.8596
2396607.5077
2396691.6949
2396697.4755
2396791.1330
2396796.9136
2396882.1463
2396880.4586
2396958.6293
2396950.8626
2396917.0060
2396868.5130
2396839.5418
2396910.4327
2396902.9459
2396838.4635
2396819.0377
2396730.1154
2396724.3347
2396630.6772
2396624.8966
2396523.0534
2396534.9288
TYP. (2)
BOLLARDS
TYP. (2)
BOLLARDS
SEE PLAN NOTES SHEET IN THIS PLAN SET FOR ALL NOTES.1.
NOTES:
TOTAL BOLLARDS)
NEEDED AROUND PROPOSED GENERATORS OR EQUIPMENT. (20
EIGHT (8) ADDITIONAL BOLLARDS TO ACCOUNT FOR ANY
TWELVE (12) BOLLARDS ARE SHOWN ON THE PLANS. INCLUDE 2.
TYP. (4)
BOLLARDS
BOLLARDS TYP. (4)
W
WVCS
W
NO INFO
W
W \UNDG
PPL 42859-S52961
WVCS
CONTROLS
GATE
METER POLE
NO INFO
S52983
PPL 42849-
0215-PSK6-530
W \UNDG
TOWER
GRAVEL
G R
A V
E L
BRUSH LINE
CHAINLINK FENCE W/BARBED WIRE
OPEN FIELD
(GRASS/STONE)
GARAGE
F I
R E
M E
N
A D
XXX
X X X
1495.85 1495.851495.851495.85
X X
X X X 1496.20
1496.201496.20
X
1496.24
X X X X
X 1496.24
1496.24
1496.24 1496.24
1496.201496.20
1495.80
1496.25
XX
1496.20 X 1496.10
X 1495.00
X 1495.00
X1495.55
X 1495.25
X 1495.30
X 1495.20
1495.85 X
1495.00 X
1495.00 X
1495.00 X
1494.70 X
1495.00 X
1495.40 X
1495.00 X
X 1494.30
X 1494.60
1492.75 X
X
1496.20
1495.85 X
X
1496.20 X
1496.20 X X X
1496.20 1496.20
X
1496.24
X
1496.24
1496.24 1496.24
X X X X X
1496.27
X1496.15
X 1495.00
X1495.55
X 1495.20
X 1495.00
X
1495.20 1495.20
X 1495.20
X 1495.20
X
1495.40 X
1495.40 X
1495.40 X
1495.40 X
1495.40
X
1495.40
X
1494.80
X
X
X
1493.50
X
1493.75
X
X
1493.75
X
X
1493.75
X
X 1493.00
X 1493.00
X 1495.20
X 1495.85
X 1495.85
X 1495.85
X
X
X X
1495.64
1495.50
1495.50
X X
1495.64
1495.55
1494.60
X
1495.50
1495.64
X 1494.70
1494.65
1494.70
1494.70
1495.86
X X
1495.85 1495.55
X 1495.64
Sheet No.:Drawn: Designed: Checked:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.:
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
32008.00 kmarmas 09\02\2026 13:03:06 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\05_Pr_Grading.dgn (Default) reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, OFKAM KAM KRR 1509/02/2026
West Mahanoy & Ryan Townships, Schuylkill County, Pennsylvania
COUNTY OF SCHUYKILL
FIREMEN'S ASSOCIATION
SCHUYLKILL COUNTY VOLUNTEER
0325-900015.01
IN0-0
PROPOSED LEGEND
GP
PROPOSED WOODS/BRUSH LINE
PROPOSED RIPRAP
PROPOSED ENDWALL/HEADWALL
PROPOSED STORM INLET & STRUCTURE LABEL
PROPOSED STORM PIPE
PROPOSED GRINDER PUMP
PROPOSED SANITARY FORCE MAIN
PROPOSED SANITARY SEWER LINE
PROPOSED WATER LINE & GATE VALVE
PROPOSED UNDERGROUND ELECTRIC LINE, TELCOM LINE
PROPOSED MINOR CONTOUR
PROP0SED MAJOR CONTOUR
OS-1
IN1-1
IN1-2
IN3-1
EW1
15"
OS-2
0 6030 FEET
SITE GRADING & UTILITY PLAN
WV
EXISTING LEGEND
1. SEE PLAN NOTES SHEET IN THIS PLAN SET FOR ALL NOTES.
NOTES:
EMERGENCY SPILLWAY
EMERGENCY SPILLWAY
EMERGENCY SPILLWAY
BOTTOM ELEV 1485.00
RAIN GARDEN 2 (BMP 5)
BOTTOM ELEV 1490.75
RAIN GARDEN 1 (BMP 3)
SWALE 2
FFE 1496.30
10,880 S.F.
BUILDING
PROPOSED
UNDERGROUND ROOF DRAINS (TYP.)
UNDERGROUND ROOF DRAIN PIPE INFORMATION
INV. 1488.90 INV. 1487.75
INV. 1491.50
INV. 1490.75
BOTTOM ELEV = 1487.75
PERMANENT INFLITRATION BASIN 2 (BMP 2)
CLEANOUTS.
ADDITIONAL INFORMATION ON UNDERGROUND ROOF DRAINS AND
SEE PLAN NOTES SHEET AND DETAIL SHEETS IN THIS PLAN SET FOR
MINIMUM ROOF DRAIN PIPE SLOPE FOR 8" OR LARGER PIPE = 0.50%
MINIMUM ROOF DRAIN PIPE SLOPE FOR 6" PIPE = 1.50%
MATERIAL = SDR 35 PVC
MINIMUM ROOF DRAIN PIPE DIAMETER = 6"
SPILLWAY
EMERGENCY
BOTTOM ELEV = 1486.75
(BMP 1)
PERMANENT MRC BASIN 1
GP
WV
WV CS'S
METER
WATER
METER
WATER
METER
WATER
WV CS
HYDRANT
YARD
MH
MH
INV=1481.80'
TOP OF CO
MH
SAN COSAN CO
PUMP STATION
FAMA SANITARY
I PIN (FND)
WEST MAHANOY TOWNSHIP
RYAN TOWNSHIP
I PIN (FND)
I PIN (FND)
FFE EXHIBIT
PROPOSED GARAGE
ELEV. 1496.30
0.00%
EXHIBIT)
(SEE FFE
3,200 S.F.
GARAGE
PROPOSED
LEVEL
FOOTPRINT
GARGAGE
PROPOSED
NOT TO SCALE
CRADLE
CONCRETE
CRADLE
CONCRETE
X
1495.64 1495.64
X
1495.64
X
FINAL DIMENSIONS AND SLOPES.
APPROXIMATE, SEE ARCHITECTURAL PLANS FOR
NOTE: DIMENSIONS AND SLOPES ARE
X X X
1495.64 1495.64 1495.64
UNDERDRAIN
MRC BASIN
SWALE 1 (BMP 4)
NOT BE DISTURBED
EXISTING WATERLINE TO
NOT TO SCALE
EXHIBIT
DOOR LANDING
PROPOSED SIDEWALK
LANDING
DOOR
PROPOSED
PROPOSED BUILDING FFE 1496.30
X X
X
BOTTOM STEP ELEV 1495.85
TOP STEP ELEV 1496.15
X
BOTTOM STEP ELEV 1495.70
TOP STEP ELEV 1496.15
BOTTOM STEP ELEV 1495.55
TOP STEP ELEV 1496.15
BOTTOM STEP ELEV 1495.64
TOP STEP ELEV 1496.30
EXHIBIT)
(SEE
LANDING
DOOR
X 1489.17
1488.37
XX
1489.17
X
1489.55
X 1484.96
1485.47
1485.14
X
X
X1484.60
(TYPICAL)
RIPRAP APRONS
UNDERGROUND ROOF DRAIN
ELEV=1505.97'
PROPERTY CORNER (FND)
IRON PIN W/ ALUMINUM CAP
BM "B"
ELEV=1482.57'
OF THE CUL-DE-SAC OF FIREMAN'S ROAD
MAGNAIL SET IN PAVE AT THE SOUTH END
BM "A"
BM "A"
BM "B"
FAMA PROJECT)
AS PART OF SEPARATE
(PREVIOUSLY REMOVED
CONNECTION LOCATION WITH FAMA)
(CONTRACTOR TO COORDINATE
PRESSURE SANITARY SEWER MAIN
CONNECT TO FAMA'S LOW
CURB STOP
PROPOSED
STARTING STATION 0+00
SWALE 1 BASE LINE
SWALE 1 BASE LINE
SWALE 2 BASE LINE
STARTING STATION 10+00
SWALE 2 BASE LINE
CLEANOUT (TYP.)
CONCRETE PAD
OUT WITH
PROPOSED CLEAN
CLEANOUT AFTER THE BUILDING AND COVERED PARKING AREA.
REMAINING UNDERGROUND ROOF DRAIN PIPES BEYOND THE FIRST
AND UTILITY PLAN AND THESE NOTES FOR INFORMATION ON ALL
ON THE GRADING AND UTILITY PLAN IN THIS PLAN SET. SEE GRADING
COVERED PARKING AREA FOOTPRINT TO THE FIRST CLEANOUT AS SHOWN
OF PIPES LEAVING THE BUILDING FOOTPRINT AND LEAVING THE
INFORMATION, INCLUDING PIPE DIAMETER, FOR THE FIRST SECTION
SEE PLUMBING PLAN FOR UNDERGROUND ROOF DRAIN PIPE
(APPROXIMATE LOCATION)
FAMA LOW PRESSURE FORCE MAIN
ON SHEET 2)
UTILITY PLAN NOTE 32
(SEE GRADING &
VALVE AND METER
TAPPING SLEEVE, WATER
(12 ON PLAN, ASSUME 8 ADDITIONAL)
BOLLARD (TYPICAL)
MUNICIPAL BOUNDARY
BUILDING SETBACK LINE
LEGAL RIGHT-OF-WAY LINE
BRUSH LINE
EXISTING PROPERTY LINE
EXISTING DRIANAGE PIPE
EXISTING WATER VALVE
EXISTING WATERLINE
EXISTING GUIDERAIL
EXISTING EDGE ROAD / SHOULDER
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
EXISTING FENCE
Scale: AS NOTED Date: Project No.:
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
32008.00 kmarmas 09\02\2026 13:03:07 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\06_Profiles.dgn (Default) reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, OFKAM KAM KRR 1509/02/2026
West Mahanoy & Ryan Townships, Schuylkill County, Pennsylvania
COUNTY OF SCHUYKILL
FIREMEN'S ASSOCIATION
SCHUYLKILL COUNTY VOLUNTEER
0325-900015.01
INV (OUT )= 1484.48(E)
15101510
15101510
@ 0.64%
15" SLCPP
31.18' OF
@ 1.69%
35.81' OF
15101510
15101510
@ 0.58%
26.70' OF
INV (OUT )= 1484.48(E)
15101510
15101510
OS-2 TO IN1-1OS-1 TO IN1-1 IN3-1 TO EW1
0+00-1+00 1+00-1+00 0+00 1+00 -1+00 0+00 1+00
@ 0.84%
59.76' OF
EXISTING GRADE
PROPOSED GRADE
PROPOSED GRADE
EXISTING GRADE
EXISTING GRADE
PROPOSED GRADE
INV (OUT) = 1486.00 (E)
TG =1491.60
E 2396848.3586 N 529848.9560
INV (OUT) = 1485.60(SE)
INV (IN )= 1485.80(W)
TG =1488.00
E 2396881.4366 N 529851.7822
INV (OUT) = 1484.75(NE)
TG =1488.10
E 2396894.4483 N 529800.6951
INV (OUT) = 1487.25(N)
TG =1491.25
E 2396897.5924 N 529640.0565
INV = 1486.75(N)
E 2396885.6200 N 529699.6275
INV (IN )= 1484.60(NW)
INV (IN )= 1484.60(SW)
TG =1488.60
E 2396911.4128 N 529824.9843
IN1-1 (4'X4' BOX)
BETWEEN PIPES
MINIMUM 18" CLEARANCE
SEWER TO PROVIDE
TO DUCK UNDER STORM
PROPOSED WATER SERVICE
15" RCP
INV (IN )= 1484.60(NW)
INV (IN )= 1484.60(SW)
TG =1488.60
E 2396911.4128 N 529824.9843
IN1-1 (4'X4' BOX)
15" RCP
BETWEEN PIPES
MINIMUM 18" CLEARANCE
STORM SEWER TO PROVIDE
FORCE MAIN TO DUCK UNDER
SERVICE LOW PRESSURE
PROPOSED SANITARY SEWER
15301530
DATUM:
ELEVATION 1490.75
1.45%
2.40%
SWALE 2 PROFILE
15301530
0 1 2 3 4
DATUM:
2.06%
6.
2.15%
ELEVATION 1487.75
SWALE 1 PROFILE
PROPOSED GRADE
EXISTING GRADE
PROPOSED GRADE
EXISTING GRADE
10 11 12 13 14
0 10050 FEET
HORIZONTAL
0 2010 FEET
VERTICAL
STORM SEWER & SWALE PROFILES
I PIN (FND)
W
WVCS
SAN CO
MH
W
NO INFO
W
I PIN (FND)
W \UNDG
PPL 42859-S52961
WVCS
MH
HYDRANT
YARD
WV CS'S
WV
CONTROLS
GATE
I PIN (FND)
WV CS
METER
WATER
METER POLE
NO INFO
S52983
PPL 42849-
SAN CO
SAN CO
0215-PSK6-530
W \UNDG
TOWER
GRAVEL
G R
A V
E L
METER
WATER
METER
WATER
BLDG
BLOCK
BRUSH LINE
CHAINLINK FENCE W/BARBED WIRE
INV=1481.80'
TOP OF CO
MH
OPEN FIELD
(GRASS/STONE)
GARAGE
RYAN TOWNSHIP
WEST MAHANOY TOWNSHIP
F I
R E
M E
N
A D
Sheet No.:Drawn: Designed: Checked:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.:
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Alfred Benesch & Company
32008.00 kmarmas 09\02\2026 13:03:10 Y:\Pennsylvania\03XX-90S\0325-900015.01\Eng_Docs\Construction Plans\07_ES Plan.dgn (Default) reuse, reproduction or modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2026, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of Alfred Benesch & Company. Use, OFKAM KAM KRR 1509/02/2026
West Mahanoy & Ryan Townships, Schuylkill County, Pennsylvania
COUNTY OF SCHUYKILL
FIREMEN'S ASSOCIATION
SCHUYLKILL COUNTY VOLUNTEER
0325-900015.01
E&SPC LEGEND
TTS
TP-01 LOCATION & NUMBER
INFILTRATION TEST
STOCKPILE
TEMPORARY TOPSOIL
SOIL TYPE
CONCRETE WASHOUT AREA
CHANNEL/SPILLWAY LINING
EROSION CONTROL BLANKET
ROCK CONSTRUCTION ENTRANCE
INLET PROTECTION
CLEAN OUT STAKE
SKIMMER
ROCK FILTER
COMPOST FILTER SOCK (SIZE AS INDICATED)
PROJECT SITE AREA (NPDES BOUNDARY) (3.10 AC.)
LIMIT OF DISTURBANCE (3.10 AC.)
SOIL BOUNDARY (ENTIRE SITE IS ONE SOIL TYPE)
TEMPORARY CONTOUR
IN0-0
PROPOSED LEGEND
GP
PROPOSED WOODS/BRUSH LINE
PROPOSED RIPRAP
PROPOSED ENDWALL/HEADWALL
PROPOSED STORM INLET & STRUCTURE LABEL
PROPOSED STORM PIPE
PROPOSED GRINDER PUMP
PROPOSED SANITARY FORCE MAIN
PROPOSED SANITARY SEWER LINE
PROPOSED WATER LINE & GATE VALVE
PROPOSED UNDERGROUND ELECTRIC LINE, TELCOM LINE
PROPOSED MINOR CONTOUR
PROP0SED MAJOR CONTOUR
TTS
15"
0 6030 FEET
WV
EXISTING LEGEND
EROSION & SEDIMENTATION CONTROL PLAN
1. SEE PLAN NOTES SHEET IN THIS PLAN SET FOR ALL NOTES.
NOTES:
3,200 S.F.
GARAGE
PROPOSED
BOTTOM ELEV 1485.00
RAIN GARDEN 2 (BMP 5)
BOTTOM ELEV 1490.75
RAIN GARDEN 1 (BMP 3)
PENNSYLVANIA ONE CALL SYSTEM SERIAL NUMBER
20230823233, 20230823234
START OF EXCAVATION.
THAN 10 BUSINESS DAYS PRIOR TO THE
LESS THAN 3 BUSINESS DAYS NOR MORE
DIAL 8-1-1 OR 1-800-242-1776 NOT
WWW.PAONECALL.ORG
COORDINATE YOUR PROJECTS VIA COORDINATE PA AT
P E
N N S Y L V
AN
I
ONE CALL
SYST
E
M
N C
D I
8-
-1
BEFORE
U
D
G
SWALE 2
UNDERGROUND ROOF DRAINS (TYP.)
CLEANOUT (TYP.)
EMERGENCY SPILLWAY
EMERGENCY SPILLWAY
EMERGENCY SPILLWAY
SPILLWAY
EMERGENCY
RCE2
RCE1
CWA1
FILTER BAG
PUMPED WATER
RF2
RF3
X
DP001
X
DP002
GP
BOTTOM ELEV = 1487.75
PERMANENT INFLITRATION BASIN 2 (BMP 2)
TEMPORARY SEDIMENT TRAP 2
RF1
EX-HW1
EX-IN3
EX-IN1
EX-IN2
EX-IN4
PERM. BOTTOM ELEV.: 1486.75
PERMANENT MRC BASIN 1 (BMP 1)
TEMP. BOTTOM ELEV.: 1485.75
TEMPORARY SEDIMENT TRAP 1
TP-01
TP-02
TP-03
TP-04
TP-05
SWALE 1 (BMP 4)
CONCRETE CRADLE
UNDERDRAIN
MRC BASIN
MUNICIPAL BOUNDARY
BUILDING SETBACK LINE
LEGAL RIGHT-OF-WAY LINE
EXISTING WOODS/BRUSH LINE
EXISTING PROPERTY LINE
EXISTING DRIANAGE PIPE
EXISTING WATER VALVE
EXISTING WATERLINE
EXISTING GUIDERAIL
EXISTING EDGE ROAD / SHOULDER
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
EXISTING FENCE
(TYPICAL)
RIPRAP APRONS
UNDERGROUND ROOF DRAIN
(APPROXIMATE LOCATION)
FAMA LOW PRESSURE FORCE MAIN
10,880 S.F.
FFE 1496.30
BUILDING
PROPOSED
SHEET 2)
NOTE 32 ON
UTILITY PLAN
(SEE GRADING &
METER
WATER VALVE AND
CONTROL PLAN DETAILS
EROSION AND SEDIMENT POLLUTION
EROSION AND SEDIMENTATION CONTROL POLICIES
SEEDING & MULCHING SPECIFICATIONS
NPDES PERMIT NOTES
FILL MATERIALS NOTES AND ENVIRONMENTAL DUE DILIGENCE
CRITICAL STAGES OF BMP IMPLEMENTATION
PREPAREDNESS, PREVENTION AND CONTINGENCY PLANS
AT THE DEPARTMENT'S OR AUTHORIZED COUNTY CONSERVATION DISTRICT'S REQUEST.
IMPLEMENTED FOR EACH IDENTIFIED AREA. THE PPC PLAN SHALL BE MAINTAINED ON SITE AT ALL TIMES AND SHALL BE MADE AVAILABLE FOR REVIEW
ANY TOXIC OR HAZARDOUS SUBSTANCES SUCH AS OIL, GASOLINE, PESTICIDES, HERBICIDES, SOLVENTS, ETC. BMPS SHALL BE DEVELOPED AND
POTENTIAL TO CAUSE NON-COMPLIANCE WITH THE TERMS AND CONDITIONS OF THE NPDES PERMIT DUE TO THE STORAGE, HANDLING OR DISPOSAL OF
STORAGE AREAS, TEMPORARY AND PERMANENT SPOILS STORAGE AREAS, MAINTENANCE AREAS, AND ANY OTHER AREAS THAT MAY HAVE THE
REGULATIONS. THE PPC PLAN SHALL IDENTIFY AREAS WHICH MAY INCLUDE, BUT ARE NOT LIMITED TO, WASTE MANAGEMENT AREAS, RAW MATERIAL
PREPAREDNESS, PREVENTION AND CONTINGENCY (PPC) PLAN. THE PPC PLAN SHALL BE DEVELOPED IN ACCORDANCE WITH APPLICABLE DEP
SAFETY THROUGH ACCIDENTAL RELEASE OF TOXIC, HAZARDOUS, OR OTHER POLLUTING MATERIALS, THE PERMITTEE OR CO-PERMITTEE MUST DEVELOP A
IF THE POTENTIAL EXISTS FOR CAUSING ACCIDENTAL POLLUTION OF AIR, LAND, OR WATER, OR FOR CAUSING ENDANGERMENT OF PUBLIC HEALTH AND
FERTILIZER: 10-10-20 ANALYSIS COMMERCIAL FERTILIZER TO BE APPLIED AT 210 LBS./1,000 SQ. YDS.
LIME: AGRICULTURAL LIME AT 2,480 LBS/1,000 SQ. YDS.
PERMANENT APPLICATION:
FERTILIZER: 10-10-10 ANALYSIS COMMERCIAL FERTERLIZER TO BE APPLIED AT 100 LBS./1,000 SQ. YDS.
LIME: AGRICULTURAL LIME AT 410 LBS/1,000 SQ. YDS.
TEMPORARY APPLICATION:
1. SUPPLEMENTS SHALL CONFORM TO THE REQUIREMENTS OF PADOT PUBLICATION 408, SECTION 804 AND SHALL BE APPLIED DURING THE APPROPRIATE TIMES.
SOIL SUPPLEMENTS:
ACCORDANCE WITH SECTION 805.3.
4. MULCH SHOULD BE ANCHORED IMMEDIATELY AFTER APPLICATION TO PREVENT BEING WINDBLOWN. ANCHOR MULCH WITH SPECIFIED MULCH BINDERS APPLIED IN
SLOPES OF 3:1 OR GREATER, MULCH SHALL BE SECURED THROUGH THE USE OF SPECIFIED NETTING MATERIAL.
3. STRAW MULCH SHALL BE APPLIED AT THE RATE OF 1,200 POUNDS PER 1,000 SQUARE YARDS AND APPLIED WITHIN 48 HOURS OF PLACING SEEDING. ON STEEP
TO BE GRASSED IN THE FUTURE.
2. THE MULCHING SHALL ALSO BE UTILIZED DURING WINTER MONTHS FOR GROUND COVER STABILIZATION ON TOPSOIL STOCKPILES, GRADED SLOPES AND OTHER AREAS
1. MULCHING SHALL CONSIST OF STRAW MULCH AND SHALL MEET THE SPECIFICATIONS AND APPLICATION RATES AS PRESCRIBED IN SECTION 805 OF PUBLICATION 408.
MULCHING:
VEGETATION WITHIN THESE FACILITIES.
3. BOTTOM OF THE SWM / BMP FACILITIES - REFERENCE THE PLANTING SCHEDULE ON THE LAND DEVELOPMENT PLANS FOR THE PLACEMENT OF GRASSES AND
ALL OTHER AREAS - SEE LANDSCAPING PLAN AND BMP SEEDING SCHEDULE FOR SEEDING APPLICATIONS.
LAWN AREAS - FORMULA B SEED MIXTURE WITH A SEEDING APPLICATION RATE OF 42 LBS./1,000 SQ. YDS.
PADOT FOR THE FOLLOWING APPLICATIONS:
2. PERMANENT SEEDING SHALL CONSIST OF PERENNIAL GRASSES (I.E., KENTUCKY BLUEGRASS, FESCUE, PERENNIAL RYE) AND SHALL MEET THE REQUIREMENTS OF
TRANSPORTATION (PADOT) SPECIFICATIONS FOR FORMULA E SEED MIXTURE. THE SEEDING APPLICATION RATE SHALL BE 10 LBS./1,000 SQ. YDS.
1. TEMPORARY SEEDING SHALL CONSIST OF 100 PERCENT ANNUAL RYE GRASS AND SHALL CONFORM TO THE REQUIREMENTS OF THE PA DEPARTMENT OF
SEEDING:
408, LATEST EDITION, SECTIONS 804 AND 805 AND SHALL BE APPLIED DURING THE PRESCRIBED PLANTING PERIOD.
SEEDING, MULCHING AND SOIL SUPPLEMENTS SHALL MEET THE REQUIREMENTS OF THE PA DEPARTMENT OF TRANSPORTATION (PADOT) SPECIFICATIONS, PUBLICATION
MAINTENANCE OF E&S CONTROL DEVICES
PER ACRE PER 1,000 SF PER 1,000 SY NOTESMULCH TYPE
APPLICATION RATE FOR SLOPES LESS THAN 3:1
1 TON
4-6 TONS
3 TONS
3 TONS
415 LB
1,650-2,500 LB
1,240 LB
1,240 LB
MULCH BLANKET
EROSION CONTROL
HYDROMULCH
WOOD CHIPS
HAY
STRAW
SLOPES 3:1 AND GREATER
MANUFACTURERS' INSTRUCTIONS.
APPLY BLANKET AND ANCHOR PER
47 LB
185-275 LB
140 LB
140 LB
MULCH APPLICATION RATES
SC150 (2:1) OR APPROVED EQUALS
NORTH AMERICAN GREEN S150 (3:1) AND
SEE NOTES.
AND LEGUMES
MAY PREVENT GERMINATION OF GRASSES
OTHER NATIVE FORAGE GRASSES
TIMOTHY, MIXED CLOVER AND TIMOTHY OR
WEEDS, NOT CHOPPED OR FINELY BROKEN
EITHER WHEAT OR OAT STRAW, FREE OF
3. THE APPLICATION RATE FOR ANY HYDROMULCH SHOULD BE 2,000 LB/ACRE AT A MINIMUM.
2. WOOD FIBER HYDROMULCH MAY BE APPLIED ON STEEPER SLOPES PROVIDED A TACKIFIER IS USED.
1. SHREDDED PAPER HYDROMULCH SHOULD NOT BE USED ON SLOPES STEEPER THAN 5%.
NOTES:
(NOT) FORM THAT IS SIGNED IN ACCORDANCE WITH PART B.1.C (SIGNATORY REQUIREMENTS) OF THIS PERMIT TO THE COUNTY CONSERVATION DISTRICT.
IN THE POST CONSTRUCTION STORMWATER MANAGEMENT (PCSM) PLAN HAVE BEEN INSTALLED, THE PERMITTEE CO-PERMITTEE OF THE FACILITY MUST SUBMIT A NOTICE OF TERMINATION
NOTICE OF TERMINATION, WHERE ALL STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY THAT ARE AUTHORIZED BY THIS PERMIT ARE ELIMINATED, AND BMP’S IDENTIFIED 4.
ACCEPTABLE NOI, AT LEAST 90 DAYS PRIOR TO THE EXPIRATION DATE OF THE COVERAGE.
PERMITTEE’S REQUESTING RENEWAL OF COVERAGE UNDER GENERAL NPDES PERMIT MUST SUBMIT TO THE COUNTY CONSERVATION DISTRICT AN ADMINISTRATIVELY COMPLETE AND 3.
CONSERVATION DISTRICT, BY PHONE OR PERSONAL CONTACT, FOLLOWED BY THE SUBMISSION OF A WRITTEN REPORT WITHIN 5 DAYS OF THE INITIAL CONTACT.
WHERE E&S BMP’S ARE FOUND TO BE INOPERATIVE OR INEFFECTIVE DURING AN INSPECTION, OR ANY OTHER TIME, THE PERMITTEE SHALL IMMEDIATELY CONTACT THE COUNTY 2.
TREATMENT.
UPON REDUCTION, LOSS OR FAILURE OF THE BMP’S, THE PERMITTEE AND CO-PERMITTEE SHALL TAKE IMMEDIATE ACTION TO RESTORE THE BMP’S OR PROVIDE AN ALTERNATIVE METHOD OF 1.
REGULATIONS ARE AVAILABLE ON-LINE AT WWW.PACODE.COM.
THESE APPLICABLE. IS WHICHEVER MANAGEMENT, WASTE MUNICIPAL 271 OR MANAGEMENT WASTE RESIDUAL 287 CHAPTERS CODE PA. 25 ON BASED REGULATIONS WASTE RESIDUAL
OR MUNICIPAL DEPARTMENT’S THE WITH ACCORDANCE IN MANAGED BE MUST AND WASTE IS FILL REGULATED FILL. REGULATED IS FILL CLEAN AS QUALIFY NOT DOES THAT MATERIAL FILL
DEPARTMENT’S POLICY “MANAGEMENT OF FILL”.
THE OF A APPENDIX WITH ACCORDANCE IN PERFORMED BE SHOULD TESTING FILL. CLEAN AS QUALIFIES IT IF DETERMINE TO TESTED BE MUST IT SUBSTANCE, REGULATED OF RELEASE
OR SPILL…
This is the start of the file's text. The full file is on GovTribe.