Data Center Location.pdf

PDF 3 MB Posted

Attached to
Y1DA--EHRM Training and Admin Space Support Construction - Kansas City VAMC Federal contract opportunity
Solicitation number
36C77623B0020
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document summarizes a life safety plan drawing and related federal contract opportunity for construction services. The life safety plan drawing provides details on existing building occupancy types, fire protection systems including sprinklers and pre-action systems, and suite locations and sizes for a data center located at 4801 E. Linwood Blvd. in Kansas City, Missouri. The related federal contract opportunity is a solicitation from the Department of Veterans Affairs Technology Acquisition Center Austin for EHRM Infrastructure Upgrades construction services at the Kansas City VA Medical Center, with a response due date not provided. Key work under the contract would involve upgrades to the data center and training and administrative spaces.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DA--EHRM Training and Admin Space Support Construction - Kansas City VAMC, newest first.
File Type Posted
Addendum 01 Drawings and Specifications.pdf PDF
36C77623B0020 0003.docx DOCX document
71-02-C17 Pipe Trench.pdf PDF
Technical Questions - Responses.pdf PDF
Wage Rates 4-28-23.pdf PDF
Sign in Sheet - 36C77623B0020 EHRM Training and Admin Space - KC.pdf PDF
36C77623B0020 0002.docx DOCX document
Attachment 16 - Site Visit Instructions.pdf PDF
Attachment 15 - Contractor Safety - Environmental Form.docx DOCX document
Attachment 10 - Mechanical - Drawings.pdf PDF
Attachment 9 - Plumbing - Drawings.pdf PDF
Attachment 5 - Civil - Drawings.pdf PDF
Attachment 14 - Wage Rates - 3-3-23.pdf PDF
Attachment 13 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 12 - Technology - Drawings.pdf PDF
Attachment 8 - Fire Protection - Drawings.pdf PDF
Attachment 6 - Structural - Drawings.pdf PDF
Attachment 4 - Hazardous - Drawings.pdf PDF
Attachment 2 - Specifications - Volume II - EHRM Training Support KC.pdf PDF
Attachment 1 - Specifications - Volume I - EHRM Training Support KC.pdf PDF
Attachment 11 - Electrical - Drawings.pdf PDF
36C77623B0020 0001.docx DOCX document
Attachment 17 - Site Map.pdf PDF
Attachment 7 - Architectural - Drawings.pdf PDF
Attachment 3 - General - Drawings.pdf PDF
Attachment 4 - Drawings - EHRM Training and Support KC - 31-53.pdf PDF
Attachment 2 - Specifications - Volume II - EHRM Training Support KC - Final.pdf PDF
Attachment 5 - Drawings - EHRM Training and Support KC - 54 - 72.pdf PDF
36C77623B0020_1.docx DOCX document
Attachment 3 - Drawings - EHRM Training and Support KC - 1-30.pdf PDF
Attachment 9 - Site Visit Instructions.pdf PDF
Attachment 6 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 1 - Specifications - Volume I - EHRM Training Support KC - Final.pdf PDF
Attachment 10 - Site Map.pdf PDF
Attachment 8 - Contractor Safety - Environmental Form.docx DOCX document
Attachment 7 - Wage Rates - 3-3-23.pdf PDF
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL NOTES:

THE FOLLOWING NATIONWIDE VA EQUIVALENCIES HAVE BEEN REVIEWED AND

APPROVED BY THE JOINT COMMISSION AND APPLY TO ALL BUILDINGS.

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS PERMITTED TO EXCEED 50

FEET.

3. INTERVAL SPRINKLER PIPING CONDITION & OBSTRUCTION INVESTIGATION.

4. SELF-CLOSING DOOR REQUIREMENT FOR CORRIDOR DOORS IN A

DORMITORY OCCUPANCY.

KEY NOTES:

1. NONSPRINKLERED ELECTRICAL EQUIPMENT ROOM PER SECTION

8.15.11.2 OF NFPA 13-2016 EDITION OR SECTION 9.2.6 OF NFPA 13-2019

EDITION.

2. FIRE DOOR RATING AND FRAME LABELING PLATE VERIFIED UNDER

CONTINUOUS HINGE.

3. DECOMMISSIONED DUMBWATER.

4. FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING STORAGE

SPACING REQUIREMENTS OF SECTION 8.15.10 OF NFPA 13-2016

EDITION OR SECTION 0.3.7 OF NFPA 13-2019 EDITION.

5. PRE ACTION SPRINKLER SYSTEM INSTALLED IN 1975.

X

MORGUE SUITE

SUITE DESCRIPTIONS

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

IRM SUITE

ROSTHETICS SUITE

IT DATA SUITE

GERIATRIC OFFICE

SUITE

HVAC SHOP SUITE

1,549 S.F.

3,610 S.F.

1,531 S.F.

1,776 S.F.

1,689 S.F.

NON PATIENT CARE 2

1,310 S.F.

NON PATIENT CARE

NON PATIENT CARE

NON PATIENT CARE

NON PATIENT CARE

NON PATIENT CARE

DATA CENTER

MB-100

623 MASSACHUSETTS ST., SUITE 200

LAWRENCE, KS 66044

785-842-6464 www.pec1.com

PROFESSIONAL ENGINEERING CONSULTANTS, P.A.

PEC Project # 208106-005

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

NC Engineering License No.: P-0214 NC Architectural License No.: 51254

FULLY SPRINKLERED

B

IM

/2

-0

K C

V A

E H

R M

B ld g a n d

/K C

V A

M C

B a s e m e n t_

R

.r v t

/3 /2

:2

:1

A

M

G104

LIFE SAFETY PLAN EHRM Infrastructure Upgrades –

Data Center – Kansas City, MO

4801 E. LINWOOD BLVD. KANSAS CITY, MO 64128

589-21-706

11/04/2022 MM CR

100% FINAL BID

DOCUMENTS

NTS

LIFE SAFETY PLAN

Revisions: Date:

144' TO EXIT

5,173 S.F.

File details come from the government source that posted it. Updated .