This solicitation is for EHRM infrastructure upgrades at Fort Meade. The Department of Veterans Affairs Technology Acquisition Center Austin is seeking proposals for construction services related to EHRM training and administrative space support at the Kansas City VAMC. Key details include construction of mechanical, electrical, and plumbing systems to support the training and administrative spaces. The response date is not provided. The solicitation involves upgrades to mechanical, electrical, and plumbing systems to support the specified spaces.
View the file
Other files for this federal contract opportunity
Show all 36
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATIONS
HVAC PIPING TYPES
GENERAL DUCT SYMBOLS
A/E ARCHITECT / ENGINEER
AAHX AIR TO AIR HEAT EXCHANGER
AB AIR BLENDER
AAV AUTOMATIC AIR VENT
ACC AIR COOLED CONDENSER
ACU AIR CONDITIONING UNIT
AF AFTER FILTER
AFCV AIR FLOW CONTROL VALVE
AFF ABOVE FINISHED FLOOR
AFW AIR FOIL WHEEL (FAN)
AHU AIR-HANDLING UNIT
AMP AMPERAGE
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARI AIR CONDITIONING AND REFRIGERATION
INSTITUTE
AS AIR SEPARATOR
ASME AMERICAN SOCIETY OF MECHANICAL
ENGINEERS
AW AIR WASHER
AXF AXIAL FLOW
B
B BOILER
BD BUTTERFLY DAMPER
BDD BACKDRAFT DAMPER
BFP BACKFLOW PREVENTER
BHP BRAKE HORSEPOWER
BHX BOILER BLOWDOWN HEAT EXCHANGER
BIW BACKWARD INCLINED WHEEL (FAN)
BSC BIOLOGICAL SAFETY CABINETS
BT BLOWOFF TANK
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
C
C CENTIGRADE (CELSIUS)
CC COOLING COIL
CCD COOLING COIL CONDENSATE DRAIN
CENT CENTRIFUGAL
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CFT CUBIC FEET
CFP CHEMICAL FEED PUMP
CH CHILLER
CHP CHILLED WATER PUMP
CHW CHILLER WATER
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CI CAST IRON
CM CUBIC METER
CM/S CUBIC METER PER SECOND
CO CARBON MONOXIDE
CO2 CARBON DIOXIDE
COMP COMPRESSOR UNIT
COP COEFFICIENT OF PERFORMANCE
CP CONDENSATE PUMP
CS CONDENSATE STORAGE TANK
CSG CLEAN STEAM GENERATOR
CT COOLING TOWER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CV CONSTANT VOLUME
CW COLD WATER (POTABLE)
CC CHILLED WATER COOLING COIL
CWP CONDENSER WATER PUMP
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
A
F
F FAHRENHEIT
F&T FLOAT AND THERMOSTATIC
FA FREE AREA
FC FLEXIBLE CONNECTION
FCU FAN COIL UNIT
FCUC FAN COIL UNIT COOLING ONLY
FCUH FAN COIL UNIT HEATING ONLY
FCW FORWARD CURVED WHEEL (FAN)
E
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EC EVAPORATIVE COOLER
ECC ENGINEERING CONTROL CENTER
ECU EVAPORATIVE CONDENSER UNIT
EDH ELECTRIC DUCT HEATER
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EGS EMERGENCY GAS SHUTOFF
EGT ENTERING GLYCOL TEMPERATURE
EH EXHAUST HOOD
EJ EXPANSION JOINT
EMD END OF MAIN DRIP (STEAM)
ENT ENTERING
ERC ELECTRIC REHEAT COIL
ERP ELECTRIC RADIANT PANEL
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
ETO ETHYLENE OXIDE
ETR EXISTING TO REMAIN
EUH ELECTRIC UNIT HEATER
EWC EVAPORATIVE WATER COOLER
EWT ENTERING WATER TEMPERATURE
EX. EXISTING
D
DB DECIBELS
Db DRY-BULB TEMPERATURE
DDC DIRECT DIGITAL CONTROLS
DEG DEGREE
DIA DIAMETER
DIW DEIONIZED WATER
DP DEW POINT TEMPERATURE
DPA DIFFERENTIAL PRESSURE ASSEMBLY
DPS DIFFERENTIAL PRESSURE SENSOR
DX DIRECT EXPANSION
FD FIRE DAMPER
FF FINAL FILTER
FHX FLUE GAS/FEEDWATER HEAT EXCHANGER
FM FLOW METER
FOP FUEL OIL PUMP
FOT FUEL OIL TANK
FOHX FUEL OIL HEAT EXCHANGER
FPM FEET PER MINUTE
FPS FEET PER SECOND
FPTU FAN POWERED TERMINAL UNIT
FRP FIBER REINFORCED POLYESTER
FS FLOW SWITCH
FSTAT FREEZESTAT
FT FEET
FT-LB FOOT-POUND
FTR FIN TUBE RADIATION
FV FACE VELOCITY
FSD COMBINATION FIRE / SMOKE DAMPER
G
GA GAUGE
GAL GALLONS
GH GRAVITY HOOD
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GS GALVANIZED STEEL
K kg KILOGRAM kg/HR KILOGRAM PER HOUR kPa KILOPASCAL kW KILOWATT kWh KILOWATT HOUR
J
J INTENTIONALLY LEFT BLANK
I/O INPUT/OUTPUT
IAQ INDOOR AIR QUALITY
IBT INVERTED BUCKET TRAP
ICF IN-LINE CENTRIFUGAL FAN
ID INSIDE DIAMETER
IFB INTEGRAL FACE AND BYPASS
IN INCHES
IN HG INCHES OF MERCURY
IN WC INCH WATER COLUMN
IN WG INCH WATER GAUGE
IN-LB INCH-POUND
IPLV INTEGRATED PART LOAD VALUE
IRH INFRARED HEATER
IS INSECT SCREEN
IU INDUCTION UNIT
IV INLET VANES
H
HU HUMIDIFIER
H&CW HOT & COLD WATER
HAC HOUSEKEEPING AID CLOSET
HB HOSE BIBB
HC HEATING COIL
HD HEAD
HOA HAND/OFF/AUTOMATIC
HP HEAT PUMP
HP HORSEPOWER
HPDT HIGH PRESSURE DRIP TRAP
HPC HIGH PRESSURE STEAM CONDENSATE RETURN
HPS HIGH PRESSURE STEAM (61-300 PSIG)
HRC HEAT RECOVERY COIL
HRD HEAT RECOVERY DEVICE
HRP HYDRONIC RADIANT (CEILING) PANEL
HRW HEAT RECOVERY WHEEL
HSTAT HUMIDISTAT
HTM HUMIDIFIER TERMINAL
HUM HUMIDIFIER UNIT MOUNTED
HVU HEATING AND VENTILATING UNIT
HW HOT WATER
HC HOT WATER HEATING COIL
HHP HEATING HOT WATER PUMP
HHR HEATING HOT WATER RETURN
HHS HEATING HOT WATER SUPPLY
HHUH HOT WATER UNIT HEATER
HX HEAT EXCHANGER
HZ HERTZ
I
L
L LITER
L/h LITERS PER HOUR (OR LITERS/HOUR) L/m LITERS PER MINUTE (OR LITERS/MINUTE) L/s LITERS PER SECOND (OR LITERS/SECOND)
LAT LEAVING AIR TEMPERATURE
LBS/HR POUNDS PER HOUR
LF LINEAR FOOT (FEET)
LGT LEAVING GLYCOL TEMPERATURE
LH LATENT HEAT
LPG LIQUID PROPANE GAS
LPC LOW PRESSURE STEAM CONDENSATE RETURN
CLPC LOW PRESSURE STEAM CONDENSATE (CLEAN)
LLHX LIQUID TO LIQUID HEAT EXCHANGER
LPS LOW PRESSURE STEAM (0-15 PSIG)
CLPS LOW PRESSURE STEAM (CLEAN)
LSD LINEAR SLOT DIFFUSER
LTCP LOCAL TEMPERATURE CONTROL PANEL
LVG LEAVING
LVR LOUVER
LWT LEAVING WATER TEMPERATURE
NOM NOMINAL
NPLV NON-STANDARD PART LOAD VALUE
NPSH NET POSITIVE SUCTION HEAD
NTS NOT TO SCALE
N
NA NOT APPLICABLE
NC NOISE CRITERIA
NG NATURAL GAS
NGFM NATURAL GAS FLOWMETER
NOAA NATIONAL OCEANIC & ATMOSPHERIC
ADMINISTRATION
M
M METER, SI UNIT
M/s METERS PER SECOND
(OR METERS/SECOND)
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAU MAKE-UP AIR UNIT
MAV MANUAL AIR VENT
MAX MAXIMUM
MB MIXING BOX
MBH 1000 BTUH
MCA MINIMUM BRANCH CIRCUIT AMPACITY
MERV MINIMUM EFFICIENCY REPORTING VALUE
MH MANHOLE
MHP MOTOR HORSEPOWER
MIN MINIMUM
MM MILLIMETER
MOV MOTOR OPERATED VALVE
MPC MEDIUM PRESSURE STEAM CONDENSATE
RETURN
MPS MEDIUM PRESSURE STEAM (16-60 PSIG)
MTD MEAN TEMPERATURE DIFFERENCE
MVD MANUAL VOLUME DAMPER
MZ MULTI-ZONE
P
P PUMP
PA PASCAL
PC PUMPED CONDENSATE
PCF POUNDS PER CUBIC FOOT (FEET)
PD PRESSURE DROP
PF PRE-FILTER
PG PRESSURE GAGE
PGW PROPYLENE GLYCOL-WATER (SOLUTION)
PHC PREHEAT COIL
PPM PARTS PER MILLION
PRS PRESSURE REGULATING (VALVE) STATION
PRV PRESSURE REGULATING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH – ABSOLUTE
PSIG POUNDS PER SQUARE INCH – GAGE
PSS PRIMARY SECONDARY SYSTEM
PSV PRESSURE SAFETY VALVE
PTAC PACKAGED TERMINAL AIR CONDITIONER
O
OA OUTSIDE AIR
OAI OUTSIDE AIR INTAKE
OD OUTSIDE DIAMETER
OFM OIL FLOWMETER
OSD ORGANIC SOIL FILTER
Q
Q INTENTIONALLY LEFT BLANK
T&PCV TEMPERATURE AND PRESSURE
CONTROL VALVE
TAB TESTING, ADJUSTING, BALANCE
TD TEMPERATURE DIFFERENCE
TDH TOTAL DYNAMIC HEAD
TDS TOTAL DISSOLVED SOLIDS
TG TRANSFER GRILLE
TP TRAP
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TU TERMINAL UNIT
TWU THRU-WALL UNIT
SA SUPPLY AIR
SAD SOUND ATTENUATING DEVICE
SAT SUPPLY AIR TEMPERATURE
SC SHADING COEFFICIENT
SCFM STANDARD CUBIC FEET PER MINUTE
SCR SILICON CONTROLLED RECTIFIER
DSD DUCT SMOKE DETECTOR
SD SMOKE DAMPER
SEN SENSIBLE HEAT
SF SUPPLY FAN
SH STEAM HUMIDIFIER
SHC STEAM HEATING COIL
SI SQUARE INCHES
SP STATIC PRESSURE
SP GR SPECIFIC GRAVITY
SPS STATIC PRESSURE SENSOR
SQ FT SQUARE FOOT (FEET)
SS STAINLESS STEEL
SSHX STEAM TO STEAM HEAT EXCHANGER
SSR SOLID SEPARATOR
ST STEAM TRAP
SUH STEAM UNIT HEATER
SVS STEAM VENT SILENCER
SWHX STEAM TO WATER HEAT EXCHANGER
R
R/E RETURN OR EXHAUST
RA RETURN AIR
RAD REFRIGERANT AIR DRYER
RAF RADIO FREQUENCY
RAHX ROTARY AIR HEAT EXCHANGER
RAT RETURN AIR TEMPERATURE
RCCH REMOTE CONDENSER CHILLER
RCU RECIPROCATING CHILLER UNIT
RD REFRIGERANT DISCHARGE
REA RELIEF AIR
RF RETURN FAN
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RHG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID LINE
RLA RUN LOAD AMPERE
RO REVERSE OSMOSIS
RPM REVOLUTIONS PER MINUTE
RS REFRIGERANT SUCTION
RTU ROOF TOP UNIT
RV RELIEF VALVE
T
UC UNDER CUT
UH UNIT HEATER
UL UNDERWRITERS LABORATORY
URV UPBLAST UNIT VENTILATOR
U
X INTENTIONALLY LEFT BLANK
W
W WATTS
WAG WASTE ANESTHESIA GAS
Wb WET-BULB (TEMPERATURE)
WC WATER COOLED
WCCH WATER COOLED CHILLER
WCCU WATER COOLED CONDENSING UNIT
WCHP WATER COOLED HEAT PUMPS
WCPU WATER COOLED PACKAGED UNIT
WF WATER FILTER
WFM WATER FLOWMETER
WG WATER GAGE
WPD WATER SIDE PRESSURE DROP
V VALVE
VAF VANE-AXIAL FAN
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER (MANUAL OPPOSED BLADE)
VFD VARIABLE FREQUENCY DRIVE
VI VIBRATION ISOLATOR
VIV VARIABLE INLET VANES
VP VACUUM PUMP
VPS VARIABLE PRIMARY SYSTEM
VR VACUUM (STEAM CONDENSATE) RETURN
VSD VARIABLE SPEED DRIVE
VUH VERTICAL UNIT HEATER
X
V
GENERAL NOTES:
A. MECHANICAL PLANS AND SECTIONS ARE INTENDED TO ACCURATELY ILLUSTRATE THE
SCOPE OF WORK BUT ARE STILL DIAGRAMMATIC IN NATURE.
B. MECHANICAL DRAWINGS DO NOT SHOW ALL ACCESSORIES TO BE INSTALLED. THE
CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL SYSTEMS ARE FULLY
FUNCTIONAL AND COMPLIANT WITH APPLICABLE CODES.
C. THE EXISTING CONDITIONS DEPICTED IN THESE PLANS ARE BASED ON AS-BUILT
DOCUMENTATION AND INFORMATION OBTAINED FROM FIELD SURVEYS AND ARE AS
ACCURATE AS POSSIBLE. DUE TO OBSTRUCTIONS, CEILINGS, ETC., NOT ALL CONDITIONS
COULD BE VERIFIED. THE CONTRACTOR SHALL SURVEY THE SITE PRIOR TO BID AND
NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS, OBSTRUCTIONS, OR
INCONSISTENCIES PREVENTING INSTALLATION OF THE MECHANICAL SYSTEM.
D. ALL EXPOSED UNINSULATED PIPING SHALL BE PAINTED PER THE SPECIFICATION SECTION
"PAINTING".
E. COORDINATE FAN COIL (FCU) AND TERMINAL UNIT (TU/VAV/CV) REHEAT COIL RIGHT OR
LEFT HAND COIL CONNECTIONS WITH PIPING PLANS.
F. ALL FLUE AND COMBUSTION AIR PIPING FROM GAS-FIRED EQUIPMENT SHALL BE SIZED BY
THE GAS-FIRED EQUIPMENT MANUFACTURER BASED ON THE SPECIFIC PIPE ROUTING AND
ELEVATIONS FOR THIS PROJECT. REFER TO MANUFACTURERS INSTALLATION MANUAL AND
LOCAL CODE REQUIREMENTS FOR REQUIRED FLUE AND COMBUSTION AIR PIPING
MATERIALS.
G. PROVIDE VIBRATION ISOLATION FOR ALL MECHANICAL EQUIPMENT TO PREVENT
TRANSMISSION OF VIBRATION TO BUILDING STRUCTURE.
H. PROVIDE VIBRATION ISOLATORS FOR ALL PIPING SUPPORTS CONNECTED TO AND WITHIN
50' OF ISOLATED EQUIPMENT (EXCEPT AT BASE ELBOW SUPPORTS AND ANCHOR POINTS)
THROUGHOUT MECHANICAL EQUIPMENT ROOMS. DO THE SAME FOR SUPPORTS OF STEAM
MAINS WITHIN 50' OF BOILER OR PRESSURE REDUCING VALVES.
I. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL,
STRUCTURAL, CIVIL, ELECTRICAL WORK, ETC., SHOWN ON OTHER CONTRACT DOCUMENT
DRAWINGS.
J. MAINTAIN A MINIMUM OF 6′-8″ CLEARANCE TO UNDERSIDE OF PIPES, DUCTS, CONDUITS,
SUSPENDED EQUIPMENT, ETC., THROUGHOUT ACCESS ROUTES IN MECHANICAL ROOMS.
K. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICAL EQUIPMENT OR PIPING
INSULATION IS APPLIED.
L. LOCATE ALL TEMPERATURE, PRESSURE, AND FLOW MEASURING DEVICES IN ACCESSIBLE
LOCATIONS WITH STRAIGHT SECTION OF PIPE OR DUCT UP AND DOWNSTREAM AS
RECOMMENDED BY THE MANUFACTURER FOR GOOD ACCURACY.
M. COORDINATE ALL EQUIPMENT CONNECTIONS WITH MANUFACTURERS CERTIFIED
DRAWINGS. COORDINATE AND PROVIDE ALL DUCT AND PIPING TRANSITIONS REQUIRED
FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND
COORDINATE ALL DUCT AND PIPING DIMENSIONS BEFORE FABRICATION.
CWR
CWS
CD
LPC
LPS
MPC
MPS
HPC
HPS
CONDENSATE DRAIN
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
HIGH PRESSURE STEAM CONDENSATE
HIGH PRESSURE STEAM SUPPLY
MEDIUM PRESSURE STEAM CONDENSATE
MEDIUM PRESSURE STEAM SUPPLY
LOW PRESSURE STEAM CONDENSATE
LOW PRESSURE STEAM SUPPLY
VACUUM RETURN
FEEDWATER PUMP DISCHARGE
FEEDWATER PUMP SUCTION
VR
CONTINUOUS BLOWDOWN
CHEMICAL FEED
BOILER BLOWOFF BO
CF
CBD
FWPD
FWPS
A. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO
INSTALL COMPLETE AND OPERABLE PIPING SYSTEMS AS INDICATED ON THE DRAWINGS, AS
SPECIFIED AND AS REQUIRED BY CODE.
B. ELEVATIONS AS SHOWN ON THE DRAWINGS ARE TO THE CENTERLINE OF ALL PRESSURE
PIPING AND TO THE INVERT OF ALL GRAVITY PIPING.
C. MAINTAIN A MINIMUM OF 3′-6″ OF GROUND COVER OVER ALL UNDERGROUND HVAC PIPING
(EDIT DEPTH OF GROUND COVER TO SUIT FROST LINE DEPTH AND PROJECT
REQUIREMENTS).
D. UNLESS OTHERWISE NOTED, ALL CHILLED WATER AND HEATING WATER PIPING SHALL BE
3/4" SIZE (EDIT SYSTEM TYPE OR PIPE SIZE TO SUIT PROJECT REQUIREMENTS).
E. PROVIDE AN AIR VENT AT THE HIGH POINT OF EACH DROP IN THE HEATING WATER, CHILLED
WATER, AND OTHER CLOSED WATER PIPING SYSTEMS (EDIT SYSTEM TYPES TO SUIT
PROJECT REQUIREMENTS). ALL PIPING SHALL GRADE TO LOW POINTS. PROVIDE HOSE END
DRAIN VALVES AT THE BOTTOM OF ALL RISERS AND LOW POINTS.
F. UNLESS OTHERWISE NOTED, ALL PIPING IS OVERHEAD, TIGHT TO UNDERSIDE OF
STRUCTURE OR SLAB, WITH SPACE FOR INSULATION IF REQUIRED.
G. INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS, TRAPS, FLANGES, AND OTHER
APPURTENANCES REQUIRING ACCESS ARE ACCESSIBLE.
H. ALL VALVES SHALL BE INSTALLED SO THAT VALVE REMAINS IN SERVICE WHEN EQUIPMENT
OR PIPING ON EQUIPMENT SIDE OF VALVE IS REMOVED.
I. ALL BALANCING VALVES AND BUTTERFLY VALVES SHALL BE PROVIDED WITH POSITION
INDICATORS AND MAXIMUM ADJUSTABLE STOPS (MEMORY STOPS).
J. PROVIDE CHAINWHEEL OPERATORS FOR ALL VALVES IN EQUIPMENT ROOMS MOUNTED
GREATER THAN 7′-0″ ABOVE FLOOR LEVEL; CHAIN SHALL EXTEND TO 7′-0″ ABOVE FLOOR
LEVEL.
K. ALL VALVES (EXCEPT CONTROL VALVES) AND STRAINERS SHALL BE FULL SIZE OF PIPE
BEFORE REDUCING SIZE TO MAKE CONNECTIONS TO EQUIPMENT AND CONTROLS.
L. UNIONS AND/OR FLANGES SHALL BE INSTALLED AT EACH PIECE OF EQUIPMENT, IN
BYPASSES, AND IN LONG PIPING RUNS (100' OR MORE) TO PERMIT DISASSEMBLY FOR
ALTERATION AND REPAIRS.
M. PITCH STEAM PIPING DOWNWARD IN THE DIRECTION OF FLOW 1/4" IN 10' (1" IN 40') MINIMUM.
PITCH ALL STEAM RETURN LINES DOWNWARD IN THE DIRECTION OF CONDENSATE FLOW
1/2" PER 10' (1" IN 20') MINIMUM. WHERE LENGTH OF BRANCH LINES ARE LESS THAN 8', PITCH
BRANCH LINES TOWARD MAINS 1/2" PER FOOT MINIMUM.
N. PITCH UP ALL STEAM AND CONDENSATE RUNOUTS TO RISERS AND EQUIPMENT 1/2" PER
FOOT. WHERE THIS PITCH CANNOT BE OBTAINED, RUNOUTS OVER 8' IN LENGTH SHALL BE
ONE SIZE LARGER THAN NOTED.
O. TAP ALL BRANCH LINES FROM TOP OF STEAM MAINS (45° PREFERRED, 90° ACCEPTABLE).
A. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO
INSTALL COMPLETE AND OPERABLE HVAC SYSTEMS AS INDICATED ON THE DRAWINGS, AS
SPECIFIED AND AS REQUIRED BY CODE.
B. CERTAIN ITEMS SUCH AS RISES AND DROPS IN DUCTWORK, ACCESS DOORS, VOLUME
DAMPERS, ETC., ARE INDICATED ON THE CONTRACT DOCUMENT DRAWINGS FOR CLARITY
FOR A SPECIFIC LOCATION REQUIREMENT AND SHALL NOT BE INTERPRETED AS THE
EXTENT OF THE REQUIREMENTS FOR THESE ITEMS.
C. IN CORRIDORS WHERE CEILING SPEAKERS AND AIR DIFFUSERS ARE INDICATED BETWEEN
THE SAME LIGHT FIXTURES, INSTALL BOTH DEVICES AT THE QUARTER POINTS BETWEEN
THE SAME FIXTURE.
D. UNLESS OTHERWISE SHOWN, LOCATE ALL ROOM THERMOSTATS AND HUMIDISTATS 4′-0″
(CENTERLINE) ABOVE FINISHED FLOOR.
E. ALL DUCTWORK SHALL CLEAR DOORS AND WINDOWS.
F. ALL DUCTWORK DIMENSIONS, AS SHOWN ON THE DRAWINGS, ARE INTERNAL CLEAR
DIMENSIONS AND DUCT SIZE SHALL BE INCREASED TO COMPENSATE FOR DUCT LINING
THICKNESS.
G. PROVIDE ALL 90° SQUARE ELBOWS WITH DOUBLE RADIUS TURNING VANES UNLESS
OTHERWISE INDICATED. ELBOWS IN DISHWASHER, KITCHEN, AND LAUNDRY EXHAUST
SHALL BE UNVANED SMOOTH RADIUS CONSTRUCTION WITH A RADIUS EQUAL TO 1.5 TIMES
THE WIDTH OF THE DUCT. PROVIDE ACCESS DOORS UPSTREAM OF ALL ELBOWS WITH
TURNING VANES.
H. COORDINATE DIFFUSER, REGISTER, AND GRILLE LOCATIONS WITH ARCHITECTURAL
REFLECTED CEILING PLANS, LIGHTING, AND OTHER CEILING ITEMS AND MAKE MINOR DUCT
MODIFICATIONS TO SUIT.
I. FIELD ERECTED AND FACTORY ASSEMBLED AIR HANDLING UNIT COILS SHALL BE
ARRANGED FOR REMOVAL FROM THE UPSTREAM SIDE WITHOUT DISMANTLING SUPPORTS.
PROVIDE GALVANIZED STRUCTURAL STEEL SUPPORTS FOR ALL COILS (EXCEPT LOWEST
COIL) IN BANKS OVER TWO COILS HIGH TO PERMIT INDEPENDENT REMOVAL OF ANY COIL.
J. ALL AIR HANDLING UNITS SHALL OPERATE WITHOUT MOISTURE CARRYOVER.
K. LOCATE ALL MECHANICAL EQUIPMENT (SINGLE DUCT, DUAL DUCT, VARIABLE VOLUME,
CONSTANT VOLUME AND FAN POWERED BOXES, FAN COIL UNITS, CABINET HEATERS, UNIT
HEATERS, UNIT VENTILATORS, COILS, STEAM HUMIDIFIERS, ETC.) FOR UNOBSTRUCTED
ACCESS TO UNIT ACCESS PANELS, CONTROLS AND VALVING.
L. FINNED TUBE RADIATION ENCLOSURES SHALL BE WALL TO WALL UNLESS OTHERWISE
INDICATED.
M. PROVIDE FLEXIBLE CONNECTIONS IN ALL DUCTWORK SYSTEMS (SUPPLY, RETURN, AND
EXHAUST) CONNECTED TO AIR HANDLING UNITS, FANS, AND OTHER EQUIPMENT WHICH
REQUIRE VIBRATION ISOLATION. FLEXIBLE CONNECTIONS SHALL BE PROVIDED AT THE
POINT OF CONNECTION TO THE EQUIPMENT UNLESS OTHERWISE INDICATED.
PIPING GENERAL NOTES: HVAC/SHEET METAL GENERAL NOTES:
EXISTING TO BE DEMOLISHED
LIMIT OF DEMOLITION
CONNECT NEW TO EXISTINGEXISTING TO REMAIN
NEW DUCT (INSIDE DIMENSIONS: W" X D")
RS
RL
REFRIGERANT SUCTION
REFRIGERANT LIQUID
SUPPLY AIR DUCT UP
SUPPLY AIR DUCT DOWN
H
T
H
T
26-P-3
MH-100
PUMP NO. 3 IN BUILDING NO. 26
EQUIPMENT ABBREVIATION (PUMP)
DETAIL NUMBER
SHEET NUMBER
SHEET NUMBER
SECTION NUMBER
THERMOSTAT
HUMIDISTAT
TEMPERATURE SENSOR
HUMIDITY SENSOR
BUILDING NUMBER WHERE EQUIPMENT
IS LOCATED
26-TU-1-1
ITEM NUMBER (TERMINAL UNIT NO. 1)
ITEM (TERMINAL UNIT)
BUILDING NUMBER WHERE EQUIPMENT
IS LOCATED
SERVED BY AIR HANDLER UNIT NO. 1
TERMINAL UNIT TAG
MECHANICAL EQUIPMENT TAG
1 OWNER FURNISHED, CONTRACTOR
INSTALLED EQUIPMENT DESIGNATION
EXISTING TO BE DEMOLISHED
EXISTING TO REMAIN
NEW PIPE
CONNECT NEW TO EXISTING
LIMIT OF DEMOLITION
GENERAL PIPING SYMBOLS
GENERAL ANNOTATIONS
AV
STRAINERFLOAT & THERMOSTATIC
STEAM TRAP
INVERTED BUCKET
STEAM TRAP
FLANGE CONNECTION PIPE DROP
PIPE RISER TEE DOWN
TEE UP
UNION
PRESSURE REDUCING
VALVE
BALL VALVE
ANGLE GLOBE VALVE
SAFETY RELIEF VALVE
GLOBE VALVE
MANUAL OR
AUTOMATIC AIR VENT
EXPANSION JOINT
EJ
PRESSURE AND
TEMPERATURE TEST PLUG
QUICK-COUPLE HOSE
CONNECTOR
FLOW METER
HVAC PIPING SYMBOLS
CHILLED WATER RETURN
CHILLED WATER SUPPLY
CHR
CHS
HEATING HOT WATER RETURN
HEATING HOT WATER SUPPLY
HHR
HHS QV CRYOGEN VENT
DR DRIP RETURN
CAP
REDUCER (ECCENTRIC)
TYPE
AIRFLOW (CFM)
SD-1
TYPE
AIRFLOW (CFM)
RG-1
TYPE
AIRFLOW (CFM)
EG-1
SQUARE TO ROUND TRANSITION
ELBOW WITH TURNING
VANES
ROUND ELBOW
EXHAUST, RELIEF, MAKE UP, OR
OUTSIDE AIR DUCT DOWN
EXHAUST, RELIEF, MAKE UP, OR
OUTSIDE AIR DUCT UP
RETURN DUCT DOWN
RETURN DUCT UP
BRANCH DUCT WITH HIGH EFFICIENCY
TAKE-OFF (HETO) BRANCH FITTING &
MANUAL VOLUME DAMPER
BRANCH DUCT WITH CONICAL
FITTING & MANUAL VOLUME
DAMPER
DAMPERS: (BD, FD, FSD, MD, SD, VD)
BD
XX-XX
ANCHOR
TEEDIRECTION OF FLOW
S
N. CONCRETE HOUSEKEEPING PADS TO SUIT MECHANICAL EQUIPMENT SHALL BE SIZED AND
LOCATED BY THE MECHANICAL CONTRACTOR. MINIMUM CONCRETE PAD THICKNESS SHALL
BE 4". PAD SHALL EXTEND BEYOND THE EQUIPMENT A MINIMUM OF 4" ON EACH SIDE.
CONCRETE HOUSEKEEPING PADS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. IT
SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO COORDINATE SIZE
AND LOCATION OF CONCRETE HOUSEKEEPING PADS.
O. WHEN MECHANICAL WORK (HVAC, PLUMBING, SHEET METAL, ETC.) IS SUB-CONTRACTED, IT
SHALL BE THE MECHANICAL CONTRACTOR’S RESPONSIBILITY TO COORDINATE
SUBCONTRACTORS AND THE ASSOCIATED CONTRACTS. WHEN DISCREPANCIES ARISE
PERTAINING TO WHICH CONTRACTOR PROVIDES A PARTICULAR ITEM OF THE MECHANICAL
CONTRACT OR WHICH CONTRACTOR PROVIDES FINAL CONNECTIONS FOR A PARTICULAR
ITEM OF THE MECHANICAL CONTRACT, IT SHALL BE BROUGHT TO THE ATTENTION OF THE
MECHANICAL CONTRACTOR, WHOSE DECISION SHALL BE FINAL.
P. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE
SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE
ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND
RESULTS MUST BE DETERMINED BY THE PROJECT SITE CONDITIONS AND SHALL HAVE THE
APPROVAL OF THE ENGINEER BEFORE BEING INSTALLED. DO NOT SCALE DRAWINGS.
Q. ALL MISCELLANEOUS STEEL REQUIRED TO ENSURE PROPER INSTALLATION AND AS SHOWN
IN DETAILS FOR PIPING, DUCTWORK, AND EQUIPMENT (UNLESS OTHERWISE NOTED) SHALL
BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR.
R. PROVIDE ACCESS PANELS FOR INSTALLATION IN WALLS AND CEILINGS WHERE REQUIRED
TO SERVICE DAMPERS, VALVES, SMOKE DETECTORS, AND OTHER CONCEALED
MECHANICAL EQUIPMENT.
S. ALL DUCTWORK, PIPING AND EQUIPMENT SUPPORTED FROM STRUCTURAL STEEL SHALL
BE COORDINATED WITH GENERAL CONTRACTOR. ALL ATTACHMENTS TO STEEL BAR
JOISTS, TRUSSES, OR JOIST GIRDERS SHALL BE AT PANEL POINTS. PROVIDE BEAM CLAMPS
MEETING MSS STANDARDS.WELDING TO STRUCTURAL MEMBERS SHALL NOT BE
PERMITTED. THE USE OF C-CLAMPS SHALL NOT BE PERMITTED.
T. ALL ROOF MOUNTED EQUIPMENT CURBS FOR EQUIPMENT PROVIDED BY THE MECHANICAL
CONTRACTOR SHALL BE FURNISHED BY THE MECHANICAL CONTRACTOR. COORDINATE
INSTALLATION WITH GENERAL CONTRACTOR.
U. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE
COORDINATED WITH ALL OTHER TRADES INVOLVED.
V. ALL OPENINGS IN FIRE WALLS DUE TO DUCTWORK, PIPING, CONDUIT, ETC., SHALL BE FIRE
STOPPED WITH AN APPROVED FIRE STOPPING MATERIAL.
W. ALL AIR CONDITIONING CONDENSATE DRAIN LINES FROM EACH AIR HANDLING UNIT AND
ROOFTOP UNIT SHALL BE PIPED FULL SIZE OF THE UNIT DRAIN OUTLET, WITH P-TRAP, AND
PIPED TO NEAREST DRAIN. SEE DETAILS AND SPECIFICATIONS FOR DEPTH OF AIR
CONDITIONING CONDENSATE TRAP.
X. REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING, AND EQUIPMENT INSTALLATION.
P. PROVIDE AN END OF MAIN DRIP AT EACH RISE IN THE STEAM MAIN. PROVIDE CONDENSATE
DRIPS AT THE BOTTOM OF ALL STEAM RISERS, DOWNFED RUNOUTS TO EQUIPMENT,
RADIATORS, ETC., AT END OF MAINS AND LOW POINTS, AND AHEAD OF ALL PRESSURE
REGULATORS, CONTROL VALVES, ISOLATION VALVES, AND EXPANSION JOINTS.
Q. ON STRAIGHT STEAM PIPING RUNS WITH NO NATURAL DRAINAGE POINTS, INSTALL DRIP
LEGS AT INTERVALS NOT EXCEEDING 200' WHERE PIPE IS PITCHED DOWNWARD IN THE
DIRECTION OF STEAM FLOW AND A MAXIMUM OF 100' WHERE THE PIPE IS PITCHED UP SO
THAT CONDENSATE FLOW IS OPPOSITE OF STEAM FLOW.
R. STEAM TRAPS SHALL BE MINIMUM 3/4″ IN SIZE.
S. INSTALL ALL PIPING WITHOUT FORCING OR SPRINGING.
T. ALL PIPING SHALL CLEAR DOORS AND WINDOWS.
U. ALL VALVES SHALL BE ADJUSTED FOR SMOOTH AND EASY OPERATION.
V. ALL PIPING WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN
PIPING AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE
OWNER.
W. PROVIDE FLEXIBLE CONNECTIONS IN ALL PIPING SYSTEMS CONNECTED TO PUMPS,
CHILLERS, COOLING TOWERS, AND OTHER EQUIPMENT WHICH REQUIRE VIBRATION
ISOLATION EXCEPT WATER COILS. FLEXIBLE CONNECTIONS SHALL BE PROVIDED AS CLOSE
TO THE EQUIPMENT AS POSSIBLE OR AS INDICATED ON THE DRAWINGS.
X. SLOPE REFRIGERANT PIPING ONE PERCENT IN THE DIRECTION OF OIL RETURN. LIQUID
LINES MAY BE INSTALLED LEVEL.
Y. INSTALL HORIZONTAL REFRIGERANT HOT GAS DISCHARGE PIPING WITH 1/2″ PER 10'
DOWNWARD SLOPE AWAY FROM THE COMPRESSOR.
Z. INSTALL HORIZONTAL REFRIGERANT SUCTION LINES WITH 1/2″ PER 10' DOWNWARD SLOPE
TO THE COMPRESSOR, WITH NO LONG TRAPS OR DEAD ENDS WHICH MAY CAUSE OIL TO
SEPARATE FROM THE SUCTION GAS AND RETURN TO THE COMPRESSOR IN DAMAGING
SLUGS.
AA. PROVIDE LINE SIZE LIQUID INDICATORS IN MAIN LIQUID LINE LEAVING CONDENSER OR
RECEIVER. INSTALL MOISTURE LIQUID INDICATORS IN LIQUID LINES BETWEEN FILTER
DRYERS AND THERMOSTATIC EXPANSION VALVES AND IN LIQUID LINE TO RECEIVER.
BB. PROVIDE LINE SIZE STRAINER UPSTREAM OF EACH AUTOMATIC VALVE. PROVIDE SHUTOFF
VALVE ON EACH SIDE OF STRAINER.
CC. PROVIDE PERMANENT FILTER DRYERS IN LOW TEMPERATURE SYSTEMS AND SYSTEMS
USING HERMETIC COMPRESSORS.
DD. PROVIDE REPLACEABLE CARTRIDGE FILTER DRYERS WITH THREE-WAY VALVE BYPASS A
ASSEMBLY FOR SOLENOID VALVES, ADJACENT TO RECEIVERS.
EE. PROVIDE REFRIGERANT CHARGING VALVE CONNECTIONS IN LIQUID LINE BETWEEN
RECEIVER SHUTOFF VALVE AND EXPANSION VALVE.
N. UNLESS OTHERWISE NOTED, ALL DUCTWORK IS OVERHEAD, TIGHT TO THE UNDERSIDE OF
THE STRUCTURE, WITH SPACE FOR INSULATION IF REQUIRED.
M. RUNS OF FLEXIBLE DUCT SHALL NOT EXCEED 5' MAXIMUM LENGTH.
O. ALL DUCTWORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN
DUCTS, INCLUDING DIVIDED DUCTS AND TRANSITIONS AROUND OBSTRUCTIONS, SHALL BE
PROVIDED AT NO ADDITIONAL COST TO THE OWNER.
P. PROVIDE ACCESS DOORS IN DUCTWORK TO PROVIDE ACCESS FOR ALL SMOKE
DETECTORS, FIRE DAMPERS, SMOKE DAMPERS, VOLUME DAMPERS, HUMIDIFIERS, COILS,
AND OTHER ITEMS LOCATED IN THE DUCTWORK WHICH REQUIRE SERVICE AND/OR
INSPECTION.
Q. PROVIDE ACCESS DOORS IN DUCTWORK FOR OPERATION, ADJUSTMENT, AND
MAINTENANCE OF ALL FANS, VALVES, AND MECHANICAL EQUIPMENT.
R. ALL DUCTS SHALL BE GROUNDED ACROSS FLEXIBLE CONNECTIONS WITH FLEXIBLE
COPPER GROUNDING STRAPS. GROUNDING STRAPS SHALL BE BOLTED OR SOLDERED TO
BOTH THE EQUIPMENT AND THE DUCT.
S. SMOKE DETECTORS SHALL BE FURNISHED AND WIRED BY THE ELECTRICAL CONTRACTOR.
THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR MOUNTING THE SMOKE
DETECTOR IN DUCTWORK AS SHOWN ON THE DRAWINGS AND IN ACCORDANCE WITH
MANUFACTURER’S PRINTED INSTRUCTIONS.
T. TERMINATE GAS VENTS FOR UNIT HEATERS, WATER HEATERS, HIGH PRESSURE PARTS
WASHER, HIGH PRESSURE CLEANER, AND OTHER GAS APPLIANCES A MINIMUM OF 3′-0″
ABOVE ROOF WITH RAIN CAP (NOTE TO DESIGNER: EDIT APPLIANCES AND HEIGHT ABOVE
ROOF TO MEET CODE AND TO SUIT PROJECT REQUIREMENTS).
U. SEE SPECIFICATIONS FOR DUCTWORK GAUGES, BRACING, HANGERS, AND OTHER
REQUIREMENTS.
V. LOUVER SIZES, LOCATIONS, MOUNTING, AND DETAILS SHALL BE COORDINATED WITH
OTHER TRADES INVOLVED. REFER TO ARCHITECTURAL SPECIFICATIONS FOR DETAILED
DESCRIPTIONS.
DIRECTION OF PIPE
PITCH (DOWN)
FM
MV
HVAC VALVE SYMBOLS
PC PUMPED CONDENSATE
ROOM TAG
FLEXIBLE CONNECTOR
PUMP
REDUCER (CONCENTRIC)
GATE VALVE
BUTTERFLY VALVE
CHECK VALVE
THERMOMETER
PRESSURE GAUGE
STRAINER WITH BLOWOFF
AND HOSE CONNECTION
YR YEAR
Y
Z INTENTIONALLY LEFT BLANK
Z
M
CONTROL VALVE
CONTROL VALVE, THREE WAY
MOTOR CONTROLLED
VALVE
M
M
NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.
PS PUMP STATION
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:1
:2
A
M
MECHANICAL LEGEND, ABBREVIATIONS
AND GENERAL NOTES
SCP 45JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
M-000
No. REVISION DESCRIPTION DATE brenden.bond Rectangle brenden.bond Text Box
CP-1 CP-2
CWP-1
P-1
FCU-1D1
CWP-2
FT-1
ACU-1
AC-1
ACCU-1D2
18"x10"15"x10"
12"x8" 8"ø
18"x10" 15"x10"
12"x10" 10"ø 10"ø
9"ø 9"ø 8"ø
6"ø
4"ø
5"ø 6"ø8"ø
18"x10" 18"x12"
18"x10"
9"ø
5"ø
9"ø
6"ø
6"ø
18"x10"
9"ø
18"x10" 18"x10"
9"ø
9"ø
12"x10"
9"ø
10"x8"
9"ø
D10
D2
D8D8
D8D8 D8D8 D8D8
AHU-1
L-1
AHU-2
L-2
D3
D4
D3
D4
12"x24"12"x24"
16"x10"
14"x10"
10"x8"
21"x10"
7"ø
16"x10"
10"ø
14"x10"
7"ø 10"ø
12"x10"10"x8"
9"ø
6"ø
5"ø
9"ø
9"ø
12"x24" 12"x24"
16"x10"
12"x10" 10"x8"
16"x10" 8"ø8"ø
12"x10"
7"ø4"ø8"ø
10"x8"
8"ø
4"ø
6"ø
8"ø
D8D8 D8D8
EF-1D5
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:1
:4
A
M
MECHANICAL DUCT DEMOLITION PLANS
SCP 46JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
MD101
N
1/8" = 1'-0"
BASEMENT MECHANICAL DUCT DEMOLITION PLAN1N
1/8" = 1'-0"
LEVEL 1 MECHANICAL DUCT DEMOLITION PLAN2
N
1/8" = 1'-0"
LEVEL 2 MECHANICAL DUCT DEMOLITION PLAN3N
1/8" = 1'-0"
ROOF MECHANICAL DUCT DEMOLITION PLAN4
DEMOLITION KEYNOTES
D1 DEMOLISH FAN COIL UNIT AND ALL ASSOCIATED ACCESSORIES AND PIPING IN ITS ENTIRETY BACK TO THE MAIN.
D2 DEMOLISH OUTDOOR CONDENSING UNIT AND ALL ASSOCIATED PIPING AND ACCESSORIES IN ITS ENTIRETY.
D3 DEMOLISH AIR HANDLING UNIT AND ALL ASSOCIATED PIPING, DUCTWORK, AIR TERMINALS AND ACCESSORIES IN ITS ENTIRETY.
D4 DEMOLISH OUTSIDE AIR LOUVER AND ALL ASSOCIATED DUCTWORK AND ACCESSORIES IN ITS ENTIRETY. SEE ARCHITECTURAL DRAWINGS FOR WALL FINISH RESTORATION.
D5 DEMOLISH EXHAUST FAN AND ALL ASSOCIATED DUCTWORK, AIR TERMINALS AND ACCESSORIES IN ITS ENTIRETY.
D8 DEMOLISH SUPPLY, RETURN AND EXHAUST DUCTWORK, AIR TERMINALS, AND ASSOCIATED ACCESSORIES IN ITS ENTIRETY BACK TO THE ASSOCIATED MECHANICAL UNIT.
D10 DEMOLISH AIR CONDITIONING UNIT, ASSOCIATED DUCTWORK, PIPING AND ACCESSORIES IN ITS ENTIRETY.
No. REVISION DESCRIPTION DATE brenden.bond Rectangle brenden.bond
FCU-1
P-1
CWP-1
CP-1 CP-2
D1
CWP-2
2" LPC
2" LPS
2 1/2" CHS 2 1/2" CHR
D7
D12D12
FT-1
ACCU-1ACU-1
AC-1
D2
D10
D2
D7 D12D11
D7 D11 D12
D7 D11 D12 D7 D11 D12 D7 D12D11
AHU-2
AHU-1
L-2
L-1
D6
D6
D3
D3
D4
D4
D7 D11 D12 D7 D11 D12 D7 D11 D12
EF-1D5
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:1
:4
A
M
MECHANICAL PIPING DEMOLITION
PLANS
SCP 47JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
MD102
N
1/8" = 1'-0"
BASEMENT MECHANICAL PIPING DEMOLITION PLAN1N
1/8" = 1'-0"
LEVEL 1 MECHANICAL PIPING DEMOLITION PLAN2
N
1/8" = 1'-0"
LEVEL 2 MECHANICAL PIPING DEMOLITION PLAN3N
1/8" = 1'-0"
ROOF MECHANICAL PIPING DEMOLITION PLAN4
DEMOLITION KEYNOTES
D1 DEMOLISH FAN COIL UNIT AND ALL ASSOCIATED ACCESSORIES AND PIPING IN ITS ENTIRETY BACK TO THE MAIN.
D2 DEMOLISH OUTDOOR CONDENSING UNIT AND ALL ASSOCIATED PIPING AND ACCESSORIES IN ITS ENTIRETY.
D3 DEMOLISH AIR HANDLING UNIT AND ALL ASSOCIATED PIPING, DUCTWORK, AIR TERMINALS AND ACCESSORIES IN ITS ENTIRETY.
D4 DEMOLISH OUTSIDE AIR LOUVER AND ALL ASSOCIATED DUCTWORK AND ACCESSORIES IN ITS ENTIRETY. SEE ARCHITECTURAL DRAWINGS FOR WALL FINISH RESTORATION.
D5 DEMOLISH EXHAUST FAN AND ALL ASSOCIATED DUCTWORK, AIR TERMINALS AND ACCESSORIES IN ITS ENTIRETY.
D6 DEMOLISH CHILLED WATER COIL AND STEAM COIL ASSOCIATED WITH THE AIR HANDLING UNIT AND ALL ASSOCIATED ACCESSORIES AND PIPING IN ITS ENTIRETY BACK TO MAIN IN THE BASEMENT.
D7 DEMOLISH STEAM PIPING AND ASSOCIATED ACCESSORIES IN ITS ENTIRETY ALL THE WAY BACK TO THE 2" STEAM MAIN IN THE BASEMENT UTILITY TUNNEL. CAP THE MAIN AT THE TUNNEL ENTRANCE AND PREPARE FOR NEW
STEAM PIPE CONNECTION.
D10 DEMOLISH AIR CONDITIONING UNIT, ASSOCIATED DUCTWORK, PIPING AND ACCESSORIES IN ITS ENTIRETY.
D11 DEMOLISH CONDENSATE PIPING AND ASSOCIATED ACCESSORIES IN ITS ENTIRETY ALL THE WAY BACK TO THE 3" CONDENSATE MAIN IN THE BASEMENT UTILITY TUNNEL. CAP THE MAIN AT THE TUNNEL ENTRANCE FOR UTURE
USE.
D12 DEMOLISH CHILLED WATER SUPPLY AND RETURN PIPING AND ASSOCIATED ACCESSORIES IN ITS ENTIRETY ALL THE WAY BACK TO THE 2-1/2" CHILLED WATER SUPPLY AND RETURN MAIN IN THE BASEMENT CRAWL SPACE. CAP
THE MAIN AT THE CRAWL SPACE ENTRANCE FOR FUTURE USE.
No. REVISION DESCRIPTION DATE brenden.bond Rectangle brenden.bond
V D
V D
F D
VD
V D
V D
V D
VD
VD
V D
F D
VD
VD
V D
VD
MECH
B07A STAIR 1
CRAWLSPACE
CS2
MECHANICAL
B01
MECHANICAL
B07
CRAWLSPACE
CS1
MECHANICAL
B02CRAWLSPACE
CS3
CRAWLSPACE
CS4
CRAWLSPACE
CS5
CWP-1
P-1
CP-1
CP-2
CWP-2
ET-1
PGP-1
FT-1
PGT-1
HWP-1
HWP-2
HX-1
UH-1
CF-1
BT-1
WS-1
WS-2
PS-1
FCU-1
CLASSROOM / IV
TESTING
3-112
EX STOR
3-112B
EX STOR
3-112A
ADMIN
3-111 EX HAC CLOSET
3-111A
ADMIN
3-110
ADMIN
3-107
CORRIDOR
C1-3-1
TELECOM
3-108
MENS RR
3-106
WOMENS RR
3-104
CONFERENCE ROOM
3-102
EX ELEV MECH
3-100
EX ELEV
ELEV
STAIR 2
BREAKROOM
3-101
ADMIN
3-103
STAIR 1
EX ENTRY
3-105
CU-1
VRF-1-1-1
VRF-1-2
VRF-1-3
VRF-1-4
VRF-1-5
VRF-1-6
VRF-1-7
EG-1
EG-1
10"x8" OA
5"ø OA
5"ø OA
10"x10" EA
5"ø OA
5"ø OA
8"x8" OA 5"ø OA
SB-1
7 10
T
CU-211
5"ø EA
5"ø EA
FCU-2
VRF-1-1-2
VRF-1-8
9 22
UH-3
T
T
T
T
T
T
T
T
SOLO-1
SOLO-2
SOLO-4
SOLO-3
SOLO-5
SOLO-6
SOLO-7
M-201
EG-1
M-201
12"x10" OA
M-201
M-201
M-201
5"ø OA
5"ø OA
8"x8" OA
6"x6" EA
6"x6" EA
5"ø OA
8"x6" OA
5"ø OA
8"x6" OA
5"ø OA
5"ø EA
5"ø EA
8"x8" OA
5"ø OA
5"ø OA
5"ø EA
BREAKROOM
3-201
STAIR 2
EX ELEV
ELEV
CLASSROOM / IV
TESTING
3-200
CORRIDOR
C2-3-2
WAITING ROOM
3-203
STAIR 1
HAC
3-209
MENS RR
3-208
WOMENS RR
3-206
CLASSROOM / IV
TESTING
3-210
CLASSROOM / IV
TESTING
3-211
EG-1
EG-1
VRF-2-5
VRF-2-4
VRF-2-3VRF-2-1
VRF-2-2
5"ø OA
10"x10" EA
5"ø OA
5"ø OA
8"ø OA
5"ø OA
SB-2
ROOF
B07C T
T
T
T
T
VRF-2-6
VRF-2-7
UH-2
SOLO-9
SOLO-8
SOLO-10
SOLO-11
SOLO-12
M-201
EF-2
EG-1
5"ø EA
M-201
M-201
M-201
M-201
8"x8" OA
6"ø OA
6"x6" EA
6"x6" EA
5"ø OA
5"ø EA5"ø EA5"ø EA
10"x10" OA
10"x10" OA 5"ø OA5"ø OA 8"x8" OAEF-1
HRU-2HRU-1 DOAU-2DOAU-1
10"x10" OA
10"x10" OA
10"x10" OA
10"x10" OA
1 2 2
M-201
EF-3 3
M-201
M-201 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:1
:2
A
M
MECHANICAL DUCT PLANS
IHB 48JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
M-101
N
1/8" = 1'-0"
BASEMENT MECHANICAL DUCT PLAN1
N
1/8" = 1'-0"
LEVEL 1 MECHANICAL DUCT PLAN2
N
1/8" = 1'-0"
LEVEL 2 MECHANICAL DUCT PLAN3N
1/8" = 1'-0"
ROOF MECHANICAL DUCT PLAN4
KEYNOTES
1 PROVIDE DOAS UNIT ON THE ROOF AND INSTALL LEVEL FOR PROPER CONDENSATE DRAINAGE. PROVIDE WITH MANUFACTURER ROOF CURB. COORDINATE EXACT UNIT LOCATION WITH STRUCTURAL DRAWINGS. CONTRACTOR SHALL INSTALL THE UNIT TO MAINTAIN RECOMMENDED MAINTENANCE CLEARANCES AND SAFE SERVICE ACCESS. DISCONNECT BY ELECTRICAL CONTRACTOR.
2 PROVIDE OUTDOOR VRF HEAT RECOVERY UNIT ON ROOF WITH ROOF MOUNTED EQUIPMENT RAILS SECURED AT FOUR POINTS TO ROOF STRUCTURE STEEL. INSTALL UNIT LEVEL FOR PROPER OPERATION AND OIL RECOVERY.
INSTALL REFRIGERANT LINE SET, ASSOCIATED ACCESSORIES, AND WEATHERPROOF PIPE CURB ASSEMBLY AS APPLICABLE PER MANUFACTURER'S INSTRUCTIONS. SEAL PIPING PENETRATIONS THROUGH ROOF AS REQUIRED.
COORDINATE EXACT UNIT LOCATION WITH STRUCTURAL DRAWINGS. CONTRACTOR SHALL COORDINATE PIPE SIZES, PIPE LENGTHS, AND PIPE ROUTING WITH UNIT MANUFACTURER. PIPE ROUTING ON PLANS IS FOR REFERENCE ONLY. DISCONNECT BY ELECTRICAL CONTRACTOR. CONTRACTOR SHALL INSTALL THE UNIT TO MAINTAIN RECOMMENDED MAINTENANCE CLEARANCES AND SAFE SERVICE ACCESS.
3 PROVIDE AND INSTALL NEW EXHAUST FAN ON THE ROOF. COORDINATE EXACT UNIT LOCATION WITH STRUCTURAL DRAWINGS. CONTRACTOR SHALL INSTALL EXHAUST FAN A MINIMUM OF 10' AWAY FROM ANY OUTSIDE AIR INTAKE.
4 10" X 10" OUTSIDE AIR DUCT DOWN IN CHASE TO FLOOR BELOW. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES AND INSTALL ALL OUTSIDE AIR DUCTWORK BEFORE NEW HYDRONIC, PLUMBING AND FIRE SPRINKLER
PIPING INSTALLATION.
5 PROVIDE VRU IN-CEILING CASSETTE SUPPORTED FROM STRUCTURE ABOVE WITH VIBRATION ISOLATORS. ROUTE REFRIGERANT PIPING TO CEILING CASSETTE FROM ASSOCIATED BRANCH SELECTOR BOX. INSTALL UNIT LEVEL FOR PROPER CONDENSATE DRAINAGE. MAINTAIN CLEARANCES FOR MAINTENANCE ACCESS AND OUTSIDE AIR DUCT CONNECTION.
6 DUCT DOWN IN DUCT CHASE TO THE FLOOR BELOW. REFER LEVEL 1 FLOOR PLAN FOR DUCT SIZES.
7 PROVIDE AND INSTALL NEW BRANCH SELECTOR BOX ABOVE THE CEILING. COORDINATE EXACT LOCATION WITH ELECTRICAL DRAWINGS. ROUTE REFRIGERANT PIPING TO THE BRANCH SELECTOR BOX FROM ASSOCIATED VRF
HEAT RECOVERY UNIT.
8 10" X 10" EXHAUST DUCT DOWN IN DUCT CHASE TO THE FLOOR BELOW. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES AND INSTALL ALL EXHAUST AIR DUCTWORK BEFORE NEW HYDRONIC, PLUMBING AND FIRE
SPRINKLER PIPING INSTALLATION.
9 10" X 10" EXHAUST DUCT UP TO EXHAUST FAN EF-1A ON THE ROOF.
10 PROVIDE AND INSTALL NEW SPLIT SYSTEM FAN COIL UNIT. COORDINATE EXACT LOCATION WITH TELECOMMUNICATION DRAWINGS. PROVIDE REFRIGERANT PIPING FROM ASSOCIATED CONDENSING UNIT.
11 PROVIDE AND INSTALL NEW SPLIT SYSTEM CONDENSING UNIT. COORDINATE EXACT LOCATION WITH CIVIL DRAWINGS. PROVIDE REFRIGERANT PIPING TO ASSOCIATED FAN COIL UNIT.
21 10" X 10" OUTSIDE AIR DUCT DOWN THRU ROOF IN CHASE TO FLOOR BELOW. DUCT TRANSITIONS TO ROUND DUCT THEN BRANCHES OFF ONTO EACH FLOOR, SEE FLOOR VIEWS FOR ROUND DUCT SIZING. CONTRACTOR SHALL
PROVIDE SEALING AND LEAK PROTECTION FOR ROOF PENTRATIONS.
22 OUTSIDE AIR DUCT UP TO FLOOR ABOVE.
23 DUCT SIZES ARE LIMITED TO 5" ROUND WHEN RUNNING BETWEEN STRUCTUAL TRUSSES. MATCH OUTSIDE AIR DUCT SIZING TO WHAT IS SHOWN IN VRF CASSETTE SCHEDULE ON SHEET M-601 WHEN POSSIBLE.
KEYNOTES
25 PROVIDE AND INSTALL VERTICAL STEAM TO HOT WATER DOUBLE-WALL HEAT EXCHANGER WITH PUMPED GLYCOL IN LOCATION SHOWN.
26 PROVIDE AND INSTALL HOT WATER PUMP IN LOCATION SHOWN.
27 PROVIDE AND INSTALL GLYCOL TANK IN LOCATION SHOWN.
28 PROVIDE AND INSTALL GLYCOL PUMP IN LOCATION SHOWN.
29 PROVIDE AND INSTALL HOT WATER EXPANSION TANK IN LOCATION SHOWN.
30 PROVIDE AND INSTALL CARBON FILTER IN LOCATION SHOWN.
31 PROVIDE AND INSTALL BRINE TANK IN LOCATION SHOWN.
32 PROVIDE AND INSTALL WATER SOFTENER IN LOCATION SHOWN.
33 PROVIDE AND INSTALL PUMP STATION IN LOCATION SHOWN.
No. REVISION DESCRIPTION DATE brenden.bond Rectangle brenden.bond
CRAWLSPACE
CS2
CRAWLSPACE
CS1
MECHANICAL
B02
CRAWLSPACE
CS3
CRAWLSPACE
CS5
CRAWLSPACE
CS4
MECHANICAL
B01
STAIR 1
MECH
B07A
MECHANICAL
B07
CWP-1
P-1
CP-1
CP-2
CWP-2
2" LPC
2" LPS
2 1/2" CHS
2 1/2" CHR
FT-1
CF-1
BT-1WS-1
WS-2
PS-1
HX-1
HWP-2
HWP-1
PGT-1
ET-1
PGP-1
2" LPS
1 1/2" HHS 1 1/2" HHR
BREAKROOM
3-101
STAIR 2
EX ELEV
ELEV
EX ELEV MECH
3-100
CONFERENCE ROOM
3-102
ADMIN
3-103
CORRIDOR
C1-3-1
STAIR 1
EX ENTRY
3-105
ADMIN
3-107
CLASSROOM / IV
TESTING
3-112
EX STOR
3-112B
EX STOR
3-112A
ADMIN
3-111
EX HAC CLOSET
3-111A
ADMIN
3-110
TELECOM
3-108
MENS RR
3-106
WOMENS RR
3-104
FCU-1
CU-1
VRF-1-1-1
VRF-1-2
VRF-1-3
SB-1 VRF-1-4
VRF-1-5
VRF-1-6
VRF-1-7
RL
STAIR1
B07B
5 10
RL
1 1/2" CD
1" CD
CU-211
FCU-2
VRF-1-8
VRF-1-1-2
SOLO-1
SOLO-2
SOLO-4
SOLO-3
SOLO-6
SOLO-5
SOLO-7
M-201
M-201
3/ 4"
C D
3/ 4"
C D
1 1/2" CD
3/4" CD
1 1/2" CD
1" C
D
1" CD39
M-201
M-201
M-201
BREAKROOM
3-201
STAIR 2
EX ELEV
ELEV
WAITING ROOM
3-203
CORRIDOR
C2-3-2
CLASSROOM / IV
TESTING
3-200
WOMENS RR
3-206
MENS RR
3-208
STAIR 1
HAC
3-209
CLASSROOM / IV
TESTING
3-211
CLASSROOM / IV
TESTING
3-210
VRF-2-1
VRF-2-2
VRF-2-3
VRF-2-4
VRF-2-5
SB-2
ROOF
B07C
RL
VRF-2-6
VRF-2-7
UH-2
SOLO-9
SOLO-8
SOLO-10
SOLO-11
SOLO-12
M-201
M-201
3/ 4"
C D
1 1/2" CD 1 1/2" CD
3/4" CD
3/ 4"
C D
EF-23
M-201
M-201
M-201
EF-1
DOAU-1
HRU-1 HRU-2
DOAU-2
2" CD 2" CD
2 2
17 17
RL RL
1 1/2" HHR 1 1/2" HHS 1 1/2" HHR 1 1/2" HHS
EF-3 3
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:1
:3
A
M
MECHANICAL PIPING PLANS
IHB 49JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
M-102
N
1/8" = 1'-0"
BASEMENT MECHANICAL PIPING PLAN1N
1/8" = 1'-0"
LEVEL 1 MECHANICAL PIPING PLAN2
N
1/8" = 1'-0"
LEVEL 2 MECHANICAL PIPING PLAN3
N
1/8" = 1'-0"
ROOF MECHANICAL PIPING PLAN4
KEYNOTES
1 PROVIDE DOAS UNIT ON THE ROOF AND INSTALL LEVEL FOR PROPER CONDENSATE DRAINAGE. PROVIDE WITH MANUFACTURER ROOF CURB. COORDINATE EXACT UNIT LOCATION WITH STRUCTURAL DRAWINGS. CONTRACTOR SHALL INSTALL THE UNIT TO MAINTAIN RECOMMENDED MAINTENANCE CLEARANCES AND SAFE SERVICE ACCESS. DISCONNECT BY ELECTRICAL CONTRACTOR.
2 PROVIDE OUTDOOR VRF HEAT RECOVERY UNIT ON ROOF WITH ROOF MOUNTED EQUIPMENT RAILS SECURED AT FOUR POINTS TO ROOF STRUCTURE STEEL. INSTALL UNIT LEVEL FOR PROPER OPERATION AND OIL RECOVERY.
INSTALL REFRIGERANT LINE SET, ASSOCIATED ACCESSORIES, AND WEATHERPROOF PIPE CURB ASSEMBLY AS APPLICABLE PER MANUFACTURER'S INSTRUCTIONS. SEAL PIPING PENETRATIONS THROUGH ROOF AS REQUIRED.
COORDINATE EXACT UNIT LOCATION WITH STRUCTURAL DRAWINGS. CONTRACTOR SHALL COORDINATE PIPE SIZES, PIPE LENGTHS, AND PIPE ROUTING WITH UNIT MANUFACTURER. PIPE ROUTING ON PLANS IS FOR REFERENCE ONLY. DISCONNECT BY ELECTRICAL CONTRACTOR. CONTRACTOR SHALL INSTALL THE UNIT TO MAINTAIN RECOMMENDED MAINTENANCE CLEARANCES AND SAFE SERVICE ACCESS.
3 PROVIDE AND INSTALL NEW EXHAUST FAN ON THE ROOF. COORDINATE EXACT UNIT LOCATION WITH STRUCTURAL DRAWINGS. CONTRACTOR SHALL INSTALL EXHAUST FAN A MINIMUM OF 10' AWAY FROM ANY OUTSIDE AIR INTAKE.
5 PROVIDE VRU IN-CEILING CASSETTE SUPPORTED FROM STRUCTURE ABOVE WITH VIBRATION ISOLATORS. ROUTE REFRIGERANT PIPING TO CEILING CASSETTE FROM ASSOCIATED BRANCH SELECTOR BOX. INSTALL UNIT LEVEL FOR PROPER CONDENSATE DRAINAGE. MAINTAIN CLEARANCES FOR MAINTENANCE ACCESS AND OUTSIDE AIR DUCT CONNECTION.
7 PROVIDE AND INSTALL NEW BRANCH SELECTOR BOX ABOVE THE CEILING. COORDINATE EXACT LOCATION WITH ELECTRICAL DRAWINGS. ROUTE REFRIGERANT PIPING TO THE BRANCH SELECTOR BOX FROM ASSOCIATED VRF
HEAT RECOVERY UNIT.
10 PROVIDE AND INSTALL NEW SPLIT SYSTEM FAN COIL UNIT. COORDINATE EXACT LOCATION WITH TELECOMMUNICATION DRAWINGS. PROVIDE REFRIGERANT PIPING FROM ASSOCIATED CONDENSING UNIT.
11 PROVIDE AND INSTALL NEW SPLIT SYSTEM CONDENSING UNIT. COORDINATE EXACT LOCATION WITH CIVIL DRAWINGS. PROVIDE REFRIGERANT PIPING TO ASSOCIATED FAN COIL UNIT.
16 REFRIGERANT PIPING UP TO THE ROOF.
17 ROUTE 2" CONDENSATE DRAIN PIPING TO THE STORM DRAIN.
34 ROUTE 1-1/2" HEATING HOT WATER SUPPLY AND RETURN PIPING ALL THE WAY UP TO THE ROOF THROUGH THE CHASE.
35 ROUTE 1-1/2" HEATING HOT WATER SUPPLY AND RETURN PIPING TO EACH DOAU.
36 ROUTE FULL SIZE CONDENSATE DRAIN FROM THE FAN COIL UNIT/VRF CASSETTE AND CONNECT INTO THE EXISTING CONDENSATE SYSTEM IN THE BASEMENT.
37 ROUTE CONDENSATE PIPING TO MOP SINK.
38 ROUTE CONDENSATE PIPING TO BATHROOM PLUMBING WALL.
39 ROUTE CONDENSATE PIPING DOWN IN WALL AND AIR GAP TO FLOOR DRAIN BELOW COUNTER.
40 HUMIDIFICATION SYSTEM: CONDAIR MLP RO 300, PUMP STATION (PS-1): WATER PUMP - 208/3/60, 3.5KW, 20A, HIGH PRESSURE PUMP - 460/3/60, 3.4KW, 20A.
No. REVISION DESCRIPTION DATE brenden.bond Rectangle brenden.bond
LEVEL 1
0' - 0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
PARAPET
21' - 2 3/8"
DOAU-1
CLASSROOM / IV
TESTING
3-210
CLASSROOM / IV
TESTING
3-211
10"x10" OA10"x10" OA
"x
O A
8" x8
O
A
VRF-1-3
SB-1
10"x12" OA
8"x8" OA
ADMIN
3-110
ADMIN
3-107
CORRIDOR
C1-3-1
10"x10" OA PLENUM BOX 10"x10" OA PLENUM BOX
LEVEL 1
0' - 0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
PARAPET
21' - 2 3/8"
CLASSROOM / IV
TESTING
3-210
CORRIDOR
C2-3-2
CLASSROOM / IV
TESTING
3-211
TELECOM
3-108
ADMIN
3-107
CORRIDOR
C1-3-1
EF-1
HRU-1
EF-3
"x
E A
10"x10" EA
FCU-1
VRF-2-6SB-2
5"ø OA
LEVEL 1
0' - 0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
PARAPET
21' - 2 3/8"
CLASSROOM / IV
TESTING
3-200
CORRIDOR
C2-3-2
WAITING ROOM
3-203
CONFERENCE ROOM
3-102
CORRIDOR
C1-3-1
ADMIN
3-103
10"x10" OA 10"x10" OA
10"x10" OA 6"ø OA 8"ø OA
8"x8" OA8"x8" OA
5"ø OA
VRF-2-3 VRF-2-4
5" ø
O A
8" x8
O
A
VRF-1-5 VRF-1-6
FCU-2
HRU-2
DOAU-2
LEVEL 1
0' - 0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
PARAPET
21' - 2 3/8"
VRF-1-1-2
VRF-1-1-1
8"x10" OA8"x10" OA
CLASSROOM / IV
TESTING
3-112
CLASSROOM / IV
TESTING
3-112
LEVEL 1
0' - 0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
PARAPET
21' - 2 3/8"
ADMIN
3-111
VRF-1-2
8"x8" EA
EG-1
EF-2
5"ø OA5"ø OA5"ø OA th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:1
:3
A
M
HVAC SECTION VIEWS
IHB 50JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
M-201
1/4" = 1'-0"
Section 411/4" = 1'-0"
Section 121/4" = 1'-0"
Section 53
1/4" = 1'-0"
Section 741/4" = 1'-0"
Section 85
No. REVISION DESCRIPTION DATE brenden.bond Rectangle brenden.bond
REFRIGERANT PIPING
1-1/4" O.D.
DRAIN PIPING
VENTILATION AIR
INTAKE HOLE
BRANCH DUCT
HOLE
BRANCH DUCT
HOLE
SERVICE ACCESS REQUIRED
MIN. 18"MIN. 18"
NOTE:
DETAIL BASED ON MITSUBISHI 4-WAY
THROW MODEL PLFY-P12NBMU-E.
NOTE:
DETAIL BASED ON MITSUBISHI
DUCTED MODEL PEFY-P12NMSU-E.
SERVICE AND
MAINTENANCE SPACE
ACCESS DOOR
CONTROL BOX
REFRIGERANT PIPING (GAS)
MORE THAN 11-13/16"
17-23/32"
17-23/32"
1-31/32"(TYP.)
MORE THAN 13/32"
1-31/32"(TYP.)
MORE THAN 13/16"
AIR IN
LET
AIR OUTLET
DRAIN PIPE
REFRIGERANT PIPING (LIQUID)
SERVICE SPACE
ACCESS DOOR
CONTROL BOX
27-9/16"
7-7/8"
CONNECTION PIPE OF
INDOOR UNIT (GAS) TYP.
CONNECTION PIPE OF
INDOOR UNIT (LIQUID) TYP.
17-23/32"(SQ.)
DRAIN PIPING
CONNECTION PIPE OF OUTDOOR/
WATER-SOURCE UNIT (HIGH PRESSURE)
CONNECTION PIPE OF OUTDOOR/
WATER-SOURCE UNIT (LOW PRESSURE)
NOTE:
DETAIL BASED ON MITSUBISHI
MODEL CMB-P1016NU-G.
DUCT SUPPORT
CHANNEL - ANGLE
BRACKET FRAME
UV RESISTANT
RUBBER BASE
NOTES:
1. SUPPORT STAND SHALL BE 1/4" HOT-ROLLED ZINC PLATED CARBON STEEL.
2. EXTERIOR DUCT INSULATION SHALL BE CONTINUOUS WITHIN STAND FRAME
AND PROTECTED WITH RIGID INSERTS AND SHIELDING.
3. VERIFY MAXIMUM LOADING WITH STAND MANUFACTURER AND STRUCTURAL
ENGINEER.
EXTERIOR
DUCTWORK
PROVIDE INSULATION SHIELD
& INSERT FOR ALL PIPING
(8" [200mm] MIN.)
BAND
1-5/8" [43mm] 12 GAUGE CHANNEL OR 2"x2"x1/4" [50x50x6.4mm] ANGLE
1/2" [15mm] DIA.
HANGER RODS WITH
36" [900mm] MAX.
SPACING ON EACH
CHANNEL
WELD
SADDLE
INSULATION SHIELD
AT HANGER
PROVIDE HIGH COMPRESSIVE
STRENGTH INSULATION (9 PSF
MIN. DENSITY) UNDER
INSULATION SHIELD
INSULATION (VAPOR
BARRIER TYPE IS
REQUIRED FOR LOW
TEMPERATURE PIPE)
HANGER ROD
PIPE HANGER NOTES:
1. SEE STRUCTURAL SPECIFICATIONS AND
DRAWINGS FOR DETAILED HANGER
REQUIREMENTS AND SEISMIC RESTRAINTS
FOR PALO ALTO.
5 FT
THRU [20]
6 8 10
[32][25] [40]
[65]
[50]
[75]
-1312 14 -16 -
[125][100]
[150]
[250]
[200]
[300]
[400]
[350]
[450]
[600]
[500]
20 241814 16128 1064 532 2 1/21 1/21 1 1/4
[9100] [9600][8500][7600] [8200][7000][5800] [6700][5200][4100] [4900][3700][3000] [3400][2700][2100]
--- --[4900] -[4100][3700] [4000] -[3000][2400][1800][1500]
THRU 3/4
[2100] [2100]
[2100]
[2700]
[2400]
SIDE VIEW TRAPEZE HANGER FOR UP TO 1000
LB. [453KG] UNIFORM LOAD
ADJUSTABLE CLEVIS HANGER
TYPE 1 - SEE SPECIFICATIONS
ADJUSTABLE CLEVIS HANGERTYPE
43 - SEE…