Attachment 9 - Plumbing - Drawings.pdf
PDF 1 MB Posted
- Attached to
- Y1DA--EHRM Training and Admin Space Support Construction - Kansas City VAMC Federal contract opportunity
- Solicitation number
- 36C77623B0020
About this file
This package of documents includes construction drawings and specifications for plumbing system upgrades at the Kansas City VA Medical Center. The project involves renovating and upgrading plumbing waste and vent systems, domestic water systems, and related components across multiple levels of the facility. Key aspects of the project include replacing sanitary piping from fixtures to basements, installing new vent stacks through the roof, relocating the domestic hot water heater, upgrading domestic water piping, and adding humidification supply lines. The documents provide detailed plans, diagrams, schedules and notes to guide contractor bidding and installation of the new plumbing systems according to code. They specify fixture locations and rough-in sizes, pipe and equipment specifications, and design and installation requirements. The related federal solicitation is for construction services to complete the plumbing upgrades outlined in the provided documents.
View the file
Other files for this federal contract opportunity
Show all 36
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MA
MV
CO
VEAI
FOV
FOR
FOS
LPG
NPW
NO
O
N
G
MPG
CA
CD
ACD
VAV
AW
ST
OST
GW
SS
SCW
140°ORAL EVACUATION
LABORATORY VACUUM
LABORATORY AIR
INDUSTRIAL AIR
LA
LV
OA
IA
FILTERED COLD WATERFCW
FUEL OIL DISCHARGEFOD
SQUARE FLOOR DRAIN (FD)
ROOF DRAIN (RD), SIZE & TYPESQUARE FLOOR SINK (FS)
CONDENSATE DRAIN
NATURAL GAS
NITROUS OXIDE
LIQUIFIED PETROLEUM GAS
COMPRESSED AIR
NITROGEN
MEDICAL AIR
OXYGEN
DOMESTIC HOT WATER RECIRC.
STORM DRAIN
ACID WASTE
DOMESTIC COLD WATER
DOMESTIC HOT WATER
140° DOMESTIC HOT WATER (140°)
SANITARY SEWER
GREASE WASTE
SOFTENED COLD WATER (SCW)
ACID VENT VENT
WALL CLEANOUT (WCO)
FLOOR CLEANOUT (FCO)
OVERFLOW STORM DRAIN
NON POTABLE WATER (NPW)
FUEL OIL SUPPLY
FUEL OIL RETURN
FUEL OIL VENT
AUXILIARY CONDENSATE DRAIN
CARBON DIOXIDE
MEDICAL VACUUM
MEDICAL VACUUM EXHAUSTMEDICAL AIR INTAKE
MEDIUM PRESSURE NATURAL GAS
END OF LINE CLEANOUT
PLUMBING EQUIPMENT DESIGNATIONXX-1
A. ALL PIPING SHALL BE COORDINATED WITH CIVIL UTILITY PIPING, FIRE PROTECTION,
DUCTWORK, MECHANICAL PIPING, LIGHTING, STRUCTURAL AND ARCHITECTURAL SYSTEMS.
B. PIPE CLEANOUTS SHALL BE LINE SIZE (6" MAX.). LOCATE 100' APART MAXIMUM FOR SIZES UP
THROUGH 6".
C. PLUMBING VENTS THROUGH ROOF (VTR) SHALL BE 3" MINIMUM. SMALLER VTR'S INDICATED
SHALL INCREASE TO 3" PIPE, 12" BELOW ROOF.
D. ACCESS PANELS SHALL BE PROVIDED FOR ALL WATER HAMMER ARRESTORS LOCATED IN
WALLS TO ACCESS EQUIPMENT. PANEL SHALL BE AS LARGE AS PRACTICAL FOR THE
FUNCTION THEY ARE INTENDED.
E. DO NOT SCALE DRAWINGS, SEE ARCHITECTURAL FLOOR PLAN FOR DIMENSIONS.
F. ALL PLUMBING WORK SHALL COMPLY WITH THE 2009 INTERNATIONAL PLUMBING CODE.
G. PIPE ROUTING IS SCHEMATIC AS SHOWN AND IS NOT INTENDED TO INDICATE EXACT
ROUTING. CONTRACTOR SHALL PROVIDE ANY ADDITIONAL OFFSET AND FITTINGS REQUIRED
FOR PROPER INSTALLATION AND TO MAINTAIN CLEARANCES.
H. CONCEAL PIPING ABOVE CEILING AND WITHIN WALLS OR CHASES, EXCEPT IN MECHANICAL
SPACES OR WHEN OTHERWISE NOTED.
DHWR
DHW
DCW
ABBREVIATIONS
PLUMBING PIPING TYPES
A/E ARCHITECT / ENGINEER
B
BFP REDUCED PRESSURE BACKFLOW
PREVENTER
BHP BRAKE HORSEPOWER
BT BATHTUB
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
DA
F FAHRENHEIT
FCO FLOOR CLEANOUT
FCW FILTERED COLD WATER
E
ET EXPANSION TANK
FD FLOOR DRAIN
FM FLOW METER
FOP FUEL OIL PUMP
FOV FUEL OIL VENT
G
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GT GREASE TRAP
K
J
J INTENTIONALLY LEFT BLANK
ID INSIDE DIAMETER
H
H&CW HOT & COLD WATER
HB HOSE BIBB
HD HUB DRAIN
HP HORSEPOWER
HWP HOT WATER PUMP
I
L
L/s LITERS PER SECOND (OR LITERS/SECOND)
LA LABORATORY AIR
LBS/HR POUNDS PER HOUR
NTS NOT TO SCALE
N
NC NORMALLY CLOSED
NG NATURAL GAS
M
M METER, SI UNIT
MA MEDICAL AIR
MAV MANUAL AIR VENT
MBH 1000 BTUH
P
PP PLUMBING PUMP
PA PASCAL
PD PRESSURE DROP
PG PRESSURE GAGE
PPM PARTS PER MILLION
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH – ABSOLUTE
PSIG POUNDS PER SQUARE INCH – GAGE
PTRV PRESSURE TEMPERATURE RELIEF VALVE
O
O OXYGEN
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
Q
Q INTENTIONALLY LEFT BLANK
TCV TEMPERATURE CONTROL VALVE
TD TEMPERATURE DIFFERENCE
TDH TOTAL DYNAMIC HEAD
TSTAT THERMOSTAT
TWR TEMPERED WATER RETURN
SAN SANITARY SEWER
SCFM STANDARD CUBIC FEET PER MINUTE
SQ FT SQUARE FOOT (FEET)
SS STAINLESS STEEL
ST STORAGE TANK
R
RD ROOF DRAIN
RO REVERSE OSMOSIS
T
X INTENTIONALLY LEFT BLANK
W
W WASTE
WC WATER CLOSET
WG WATER GAGE
WPD WATER SIDE PRESSURE DROP
V VENT
VP VACUUM PUMP
VSD VARIABLE SPEED DRIVE
X
V
DEMOLITION GENERAL NOTES:
PL-100
DETAIL NUMBER
SHEET NUMBER
SHEET NUMBER
SECTION NUMBER
1 OWNER FURNISHED, CONTRACTOR
INSTALLED EQUIPMENT DESIGNATION
EXISTING TO BE DEMOLISHED
EXISTING TO REMAIN
NEW PIPE
CONNECT NEW TO EXISTING
LIMIT OF DEMOLITION
GENERAL PIPING SYMBOLS
GENERAL ANNOTATIONS
AV
STRAINER
FLOAT & THERMOSTATIC
STEAM TRAP
INVERTED BUCKET
STEAM TRAP
FLANGE CONNECTION PIPE DROP
PIPE RISER
TEE DOWN
TEE UP UNION
PRESSURE REDUCING
VALVE
BALL VALVE
ANGLE GLOBE VALVE SAFETY RELIEF VALVE
GLOBE VALVE
MANUAL OR
AUTOMATIC AIR VENT
PRESSURE AND
TEMPERATURE TEST PLUG
FLOW METER
PLUMBING PIPING SYMBOLS
CAP
REDUCER (ECCENTRIC)
Name
XX-XX
ANCHOR
TEE
DIRECTION OF FLOW
S
DIRECTION OF PIPE
PITCH (DOWN)
FM
MV
PLUMBING VALVE SYMBOLS
ROOM TAG
PUMP
REDUCER (CONCENTRIC)
BUTTERFLY VALVE
CHECK VALVE
THERMOMETER
PRESSURE GAUGE
YCO YARD CLEANOUT
Y
Z INTENTIONALLY LEFT BLANK
Z
AD AREA DRAIN
AFF ABOVE FINISHED FLOOR
AG AIR GAP
AFG ABOVE FINISHED GRADE
AP ACCESS PANEL
AS AUTOMATIC SPRINKLER
ASD ADJUSTABLE SPEED DRIVES
ASD AUTOMATIC SPRINKLER DRAIN
ASME AMERICAN SOCIETY OF MECHANICAL
ENGINEERS
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATION, AIR CONDITIONING
ENGINEERS
ASPE AMERICAN SOCIETY OF PLUMBING
ENGINEERS
ASR AUTOMATIC SPRINKLER RISER
AV ACID VENT
AW ACID WASTE
BSP BLACK STEEL PIPE
C
C CENTIGRADE (CELSIUS)
CFM CUBIC FEET PER MINUTE
CV CONTROL VALVE
CO CLEANOUT
CA COMPRESSED AIR
CGA COMPRESSED GAS ASSOCIATION
CI CAST IRON
CS CLINICAL SINK
DCW DOMESTIC COLD WATER
DFU DRAINAGE FIXTURE UNITS
DHW DOMESTIC HOT WATER
DI DEIONIZED WATER
DW DISHWASHER
DHWR DOMESTIC HOT WATER RETURN
DHWS DOMESTIC HOT WATER SUPPLY
DN DOWN
DS DOWNSPOUT
DWG DRAWING
DWH DOMESTIC WATER HEATER
DWR DRINKING WATER RETURN
DWS DRINKING WATER SUPPLY
DWV DRAIN WASTE VENT
EX. EXISTING
EWS/SH EYE WASH/ DRENCH SHOWER
EWS EYE WASH STATION
EWH ELECTRIC WATER HEATER
ETR EXISTING TO REMAIN
ESH EMERGENCY SHOWER
ESC ESCUTCHEON
EPACT ENERGY POLICY ACT
EMCS ENERGY MONOSERRAT AND
CENTRAL SYSTEM
EPA ENVIRONMENTAL PROTECTION AGENCY
EL ELEVATION
F
FDC FIRE DEPARTMENT (HOSE) CONNECTION
FFA FROM FLOOR ABOVE
FFB FROM FLOOR BELOW
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FS FLOOR SINK
FS FLOW SWITCH
FU FIXTURE UNITS
GAL GALLONS
GCO GRADE CLEANOUTS
GPS GAS REGULATOR STATION
GVTR GAS VENT THROUGH ROOF
GWH GAS FIRED UNIT HEATER
HX HEAT EXCHANGER
HS HAND SINK
HST HOT WATER STORAGE TANK (DOMESTIC)
HWB HOT WATER BOILER
HWCP HOT WATER CIRCULATING PUMP
HYD HYDRANT
IE INVERT ELEVATION
ICW INDUSTRIAL COLD WATER
IHW INDUSTRIAL HOT WATER
INV INVERT
IPC INTERNATIONAL PLUMBING CODE
IRW IRRIGATION WATER
IW INDIRECT WASTE
IWH INSTANTANEOUS WATER HEATER
IWR INDUSTRIAL WATER RETURN
IWS INDUSTRIAL WATER SUPPLY
kW KILOWATT kWh KILOWATT HOUR
LAV LAVATORY
LCW LABORATORY COLD WATER
LHW LABORATORY HOT WATER
LV LABORATORY VACUUM
LNG LIQUID NATURAL GAS
LOX LIQUID OXYGEN
LW LOW WATER
MED MEDICAL
MER MECHANICAL EQUIPMENT ROOM
MH MANHOLE
MOU MEMORANDUM OF UNDERSTANDING
MSB MOP SERVICE BASIN
MV MEDICAL VACUUM
N2 NITROGEN
N2O NITROUS OXIDE
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM. NOMINAL
NPW NON POTABLE WATER
OC ON CENTER
OR OPERATING ROOM
OVFL OVERFLOW
PDI PLUMBING AND DRAINAGE INSTITUTE
PO POTABLE WATER
RDL ROOF DRAIN LEADER
RL ROOF LEADER
RP RECIRCULATION PUMP
RWL RAIN WATER LEADER
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOCIATION
SCW SOFTENED COLD WATER
SDMH STORM DRAIN MANHOLE
SMH SANITARY MANHOLE
SP SUMP PUMP
SPR SPRINKLER LINE
SW STORM WATER
TD TRENCH DRAIN
TEMP TEMPERATURE
TFA TO FLOOR ABOVE
TFB TO FLOOR BELOW
TMV THERMOSTATIC MIXING VALVE
TP TRAP PRIMER
TWS TEMPERED WATER SUPPLY
TYP TYPICAL
U
U INTENTIONALLY LEFT BLANK
VS VENT STACK
VTR VENT THROUGH ROOF
VAC VACUUM
VB VACUUM BREAKER
VCO VACUUM CLEANER OUTLET
WCO WALL CLEANOUT
WH WALL HYDRANT
WH WATER HEATER
WHA WATER HAMMER ARRESTER
WL WATER LINE
WM WATER METER
WS WASTE STACK
WSFU WATER SUPPLY FIXTURE UNITS
YH YARD HYDRANT
BACKFLOW PREVENTER
NONFREEZE WALL
HYDRANT
PLUMBING CLEANOUT AND DRAIN SYMBOLS
MODULATING CONTROL
VALVE
THERMOSTATIC MIXING
VALVE
M MOTOR OPERATED VALVE
I. SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS.
J. PROVIDE TRAP PROTECTION FOR ALL FLOOR DRAINS.
K. PROVIDE AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES, DEVICES, APPLIANCES AND APPARATUS.
L. COORDINATE PIPING WITH ELECTRICAL EQUIPMENT PRIOR TO INSTALLATION. ROUTE PIPING
TO AVOID ELECTRICAL EQUIPMENT AND CLEARANCE AREAS.
M. ANY DEVIATIONS IN ELECTRICAL REQUIREMENTS FROM THE BASIS OF DESIGN FOR THE
PLUMBING EQUIPMENT SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO
ENSURE COORDINATION WITH THE ELECTRICAL CONTRACTOR FOR PROPER SIZE
ELECTRICAL MATERIAL AND EQUIPMENT AT NO ADDITIONAL COST.
N. PROVIDE SHOCK ARRESTORS PER STANDARD PDI-WH-201.
O. SEAL ALL FIRE AND SMOKE BARRIER PENETRATIONS IN ACCORDANCE WITH THE APPLICABLE
BUILDING CODE, SPECIFICATIONS, AND DETAILS. REFER TO ARCHITECTURAL DRAWINGS FOR
LOCATIONS AND RATINGS OF FIRE AND SMOKE WALLS, BARRIERS, AND PARTITIONS.
ROUND FLOOR DRAIN (FD)
GENERAL NOTES:
A. VERIFY EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY GENERAL CONTRACTOR
REGARDING CONFLICTS BEFORE PROCEEDING WITH WORK.
B. VERIFY SIZE AND LOCATION OF EXISTING UTILITIES PRIOR TO START OF DEMOLITION.
RELOCATE, REMOVE AND ADJUST MECHANICAL AND ELECTRICAL ITEMS AS NECESSARY TO
COORDINATE WITH NEW WORK.
C. AFTER DEMOLITION IS COMPLETE, PATCH AND REPAIR FINISHES TO MATCH EXISTING
CONDITIONS.
D. COORDINATE DEMOLITION WITH GENERAL CONTRACTOR. NOTIFY GENERAL CONTRACTOR
AND OWNER IF A SHUDTOWN OF UTILITIES IS REQUIRED.
E. PROTECT EXISTING UTILITIES TO REMAIN FROM DAMAGE DURING DEMOLITION.
F. TEMPORARILY MOVE OR TAKE EQUIPMENT OUT OF SERVICE AS NECESSARY TO COMPLETE
WORK.
G. SAWCUT CONCRETE FLOOR AS REQUIRED FOR DEMOLITION WORK INDICATED. COORDINATE
WITH NEW PLUMBING BEFORE CUTTING ANY FLOOR. CONTRACTOR TO X-RAY FLOORS FOR
ALL STRUCTURAL FLOORS.
NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.
WCO WATER CLEAN OUT
PS POTABLE WATER
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:2 :4
P
M
PLUMBING LEGEND, ABBREVIATIONS
AND GENERAL NOTES
IHB 36JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
P-000
No. REVISION DESCRIPTION DATE brenden.bond Rectangle brenden.bond Text Box
WH-1
FD-C
FD-C
FD-C
D1
4" 4"
4"
4"
D20
FD-C
P-524
P-101
P-201
FD-C P-101
P-701
P502
P-414
P-414
D2
D3
D2
D4
D7
D5
D7
D4
D6
D8
P-801 D16
D1
D21D21
P-101 P-101
P-701
P-414 P-414
D7
D4 D4
D6
D7
D1
D1 D21D21
RD-1 D17
D19
D19 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:2 :0
P
M
PLUMBING WASTE AND VENT
DEMOLITION PLANS
SCP 37JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
PD101
N
1/8" = 1'-0"
BASEMENT PLUMBING WASTE AND VENT DEMOLITION PLAN1N
1/8" = 1'-0"
LEVEL 1 PLUMBING WASTE AND VENT DEMOLITION PLAN2
N
1/8" = 1'-0"
LEVEL 2 PLUMBING WASTE AND VENT DEMOLITION PLAN3N
1/8" = 1'-0"
ROOF PLUMBING WASTE AND VENT DEMOLITION PLAN4
DEMOLITION KEYNOTES
D1 DEMOLISH EXISTING SANITARY AND VENT PIPING AND ASSOCIATED ACCESSORIES IN ITS ENTIRETY ALL THE WAY BACK TO THE 4" SANITARY MAIN IN THE BASEMENT SUCH THAT THE PIPING TO REMAIN IS FLUSH WITH THE BASEMENT FLOOR. DEMOLISH AND REMOVE PIPING BELOW SLAB AND
PREPARE FOR CONNECTION TO NEW SANITARY PIPING.
D2 DEMOLISH EXISTING FLOOR DRAIN AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED SANITARY AND VENT PIPE BACK TO THE MAIN IN
BASEMENT.
D3 DEMOLISH EXISTING DOUBLE SINK AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED SANITARY AND VENT PIPING BACK TO THE MAIN IN
BASEMENT.
D4 DEMOLISH EXISTING LAVATORY AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED SANITARY AND VENT PIPING BACK TO THE MAIN IN
BASEMENT.
D5 DEMOLISH EXISTING URINAL AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED SANITARY AND VENT PIPING BACK TO THE MAIN IN BASEMENT.
D6 DEMOLISH EXISTING SHOWER AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED SANITARY AND VENT PIPING BACK TO THE MAIN IN BASEMENT.
D7 DEMOLISH EXISTING WATER CLOSET AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED SANITARY AND VENT PIPING BACK TO THE MAIN IN
BASEMENT.
D8 DEMOLISH EXISTING SERVICE SINK AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED SANITARY AND VENT PIPING BACK TO THE MAIN IN
BASEMENT.
D16 WALL HYDRANT IS EXISTING TO REMAIN. CONTRACTOR SHALL MODIFY THE PIPING AS REQUIRED AND USE THE NEW GYP WALL AND INSULATION
ADDITION TO DROP DOWN THE DOMESTIC COLD WATER PIPE.
D17 ROOF DRAIN IS EXISTING TO REMAIN.
D19 DEMOLISH ALL EXISTING VENTS THROUGH ROOF IN ITS ENTIRETY. PATCH ROOF OPENINGS TO MATCH EXISTING ROOF STRUCTURE.
D20 WATER HEATER IS EXISTING TO BE RELOCATED. DEMOLISH WATER HEATER HOUSEKEEPING PAD. REFER SHEET P-102 FOR NEW LOCATION.
D21 REFER TO SHEET P-601 FOR PLUMBING FIXTURE SCHEDULES.
No. REVISION DESCRIPTION DATE brenden.bond Rectangle brenden.bond
WH-1
FD-C
D18
1"
2 1/2"1"3/4"
D9
D20
P502
FD-C P-524
P-101
P-201
P-414
FD-C P-101
P-414
P-701
D15
D10
D11
D13
D12 D14
D11
D12
P-801 D16
D21D21
P-414P-414
P-101
P-701
P-101 D12
D11 D11
D14
D12
D21D21
RD-1 D17
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:2 :0
P
M
PLUMBING DOMESTIC WATER
DEMOLITION PLANS
SCP 38JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
PD102
N
1/8" = 1'-0"
BASEMENT PLUMBING DOMESTIC WATER DEMOLITION PLAN1N
1/8" = 1'-0"
LEVEL 1 PLUMBING DOMESTIC WATER DEMOLITION PLAN2
N
1/8" = 1'-0"
LEVEL 2 PLUMBING DOMESTIC WATER DEMOLITION PLAN3N
1/8" = 1'-0"
ROOF PLUMBING DOMESTIC WATER DEMOLITION PLAN4
DEMOLITION KEYNOTES
D9 DEMOLISH EXISTING DOMESTIC COLD WATER PIPING AND ASSOCIATED ACCESSORIES IN ITS ENTIRETY ALL THE WAY BACK TO THE DEMARCATION POINT ON THE 2-1/2" COLD WATER MAIN IN THE BASEMENT. CAP AND PREPARE THE MAIN FOR CONNECTION TO NEW COLD WATER PIPING.
D10 DEMOLISH EXISTING DOUBLE SINK AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED DOMESTIC COLD AND HOT WATER PIPING BACK TO THE
MAIN IN BASEMENT.
D11 DEMOLISH EXISTING LAVATORY AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED DOMESTIC COLD AND HOT WATER PIPING BACK TO THE MAIN
IN BASEMENT.
D12 DEMOLISH EXISTING WATER CLOSET AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED DOMESTIC COLD WATER PIPING BACK TO THE MAIN IN
BASEMENT.
D13 DEMOLISH EXISTING URINAL AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED DOMESTIC COLD WATER PIPING BACK TO THE MAIN IN
BASEMENT.
D14 DEMOLISH EXISTING SHOWER AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED DOMESTIC COLD AND HOT WATER PIPING BACK TO THE MAIN
IN BASEMENT.
D15 DEMOLISH EXISTING SERVICE SINK AND ASSOCIATED ACCESSORIES. DEMOLISH ASSOCIATED DOMESTIC COLD AND HOT WATER PIPING BACK TO THE
MAIN IN BASEMENT.
D16 WALL HYDRANT IS EXISTING TO REMAIN. CONTRACTOR SHALL MODIFY THE PIPING AS REQUIRED AND USE THE NEW GYP WALL AND INSULATION
ADDITION TO DROP DOWN THE DOMESTIC COLD WATER PIPE.
D17 ROOF DRAIN IS EXISTING TO REMAIN.
D18 DEMOLISH EXISTING DOMESTIC HOT WATER PIPING AND ASSOCIATED ACCESSORIES IN ITS ENTIRETY ALL THE WAY BACK TO THE WATER HEATER IN
THE BASEMENT. PREPARE THE WATER HEATER FOR CONNECTION TO NEW HOT WATER PIPING.
D20 WATER HEATER IS EXISTING TO BE RELOCATED. DEMOLISH WATER HEATER HOUSEKEEPING PAD. REFER SHEET P-102 FOR NEW LOCATION.
D21 REFER TO SHEET P-601 FOR PLUMBING FIXTURE SCHEDULES.
No. REVISION DESCRIPTION DATE
Ian.Baxter Image
Ian.Baxter Image
Ian.Baxter Image
Ian.Baxter Image brenden.bond Rectangle brenden.bond
CRAWLSPACE
CS5
CRAWLSPACE
CS3
CRAWLSPACE
CS4
MECHANICAL
B02
MECHANICAL
B07
MECHANICAL
B01
CRAWLSPACE
CS1
CRAWLSPACE
CS2
STAIR 1
FD-C3" SS
3" SS 4" SS
3" SS
2" SS
3" SS
4" SS
3" SS3" SS
3" SS
4" SS
4" SS
2" SS
2" SS
WH-1
WS-2
WS-1
TELECOM
3-108
CLASSROOM / IV
TESTING
3-112
EX STOR
3-112B
EX STOR
3-112A
ADMIN
3-111
EX HAC CLOSET
3-111A
ADMIN
3-107
EX ENTRY
3-105
CORRIDOR
C1-3-1
ADMIN
3-110
MENS RR
3-106
WOMENS RR
3-104
CONFERENCE ROOM
3-102
STAIR 1
ADMIN
3-103
EX ELEV MECH
3-100
BREAKROOM
3-101
EX ELEV
ELEV
STAIR 2
P502
P-101P-101
P-414 P-414
P-801
SP-1
(IN ELEVATOR
SUMP BASIN)
FD-C
WCO
WCO
FD-C
FD-C
WCO
2" V
3" SS
4" SS
2" V
1 1/2" V
(UNDER THE
SINK)
CLASSROOM / IV
TESTING
3-210
CLASSROOM / IV
TESTING
3-211
MENS RR
3-208
WOMENS RR
3-206
CLASSROOM / IV
TESTING
3-200
CORRIDOR
C2-3-2
HAC
3-209
STAIR 1
WAITING ROOM
3-203
EX ELEV
ELEV
STAIR 2
BREAKROOM
3-201
P-101 P-101
P-414P-414
P-502
STAIR1
B07B
ROOF
B07C
3" V
2" V
2" V
FD-C FD-C
RD-1
3" V
3" V
P-815 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:2 :4
P
M
PLUMBING WASTE AND VENT PLANS
SCP 39JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
P-101
PLUMBING KEYNOTES
2 REFER TO RISER DIAGRAMS ON SHEET P-301 AND P-302 FOR PIPE SIZES AND ROUTING.
3 4" SANITARY SEWER DOWN AND CONNECT TO EXISTING SANITARY PIPING FLUSH WITH THE BASEMENT FLOOR.
4 3" VENT UP THROUGH ROOF.
5 ROUTE DRAIN PIPE FROM THE ICE MACHINE TO THE FLOOR DRAIN UNDER THE COUNTER.
8 ANY PLUMBING PIPING SHOWN OUTSIDE THE CRAWL SPACE IS SHOWN FOR DRAWING CLARITY ONLY. CONTRACTOR SHALL OFF-SET THE PIPING AS
REQUIRED ON LEVEL 1 TO PENETRATE BASEMENT LEVEL INSIDE THE CRAWL SPACE.
N
1/8" = 1'-0"
BASEMENT PLUMBING WASTE AND VENT PLAN1N
1/8" = 1'-0"
LEVEL 1 PLUMBING WASTE AND VENT PLAN2
N
1/8" = 1'-0"
LEVEL 2 PLUMBING WASTE AND VENT PLAN3N
1/8" = 1'-0"
ROOF PLUMBING WASTE AND VENT PLAN4
No. REVISION DESCRIPTION DATE
Ian.Baxter Image
Ian.Baxter Image
Ian.Baxter Image
Ian.Baxter Image brenden.bond Rectangle brenden.bond
CRAWLSPACE
CS5
CRAWLSPACE
CS3
CRAWLSPACE
CS4
MECHANICAL
B02
MECHANICAL
B07
MECHANICAL
B01
STAIR 1
CRAWLSPACE
CS2
CRAWLSPACE
CS1
MECH
B07A
FD-C
WH-11
1 1/4" DHW
1 1/4" DCW
2 1/2" DCW
3/4" DHW
3/4" DCW
2 1/2" DCW
1 1/4" DHW
3/4" DCW
1/2" DHW
1/2" DCW
1/2" DCW
1" DCW
1" DCW
PS-1
WS-2
WS-1
BT-1
CF-16
P-801
P-528
CLASSROOM / IV
TESTING
3-112
EX STOR
3-112B
EX STOR
3-112A
ADMIN
3-111
EX HAC CLOSET
3-111A CORRIDOR
C1-3-1
ADMIN
3-107
ADMIN
3-110
TELECOM
3-108
MENS RR
3-106
WOMENS RR
3-104
CONFERENCE ROOM
3-102
EX ENTRY
3-105
STAIR 1
ADMIN
3-103
EX ELEV MECH
3-100
EX ELEV
ELEV
BREAKROOM
3-101
STAIR 2
P502
P-414 P-414
P-101 P-101
FD-C
3/4" DHW
3/4" DCW
WCO
FD-CFD-C
WCO
WCO
3/4" DHW
3/4" DCW
3/4" DHW2" DCW
1/2" DCW
1/2" DCW
1/2" DHW
(UNDER THE
SINK)
CLASSROOM / IV
TESTING
3-211
CLASSROOM / IV
TESTING
3-210
MENS RR
3-208
WOMENS RR
3-206
HAC
3-209
STAIR 1
WAITING ROOM
3-203
CORRIDOR
C2-3-2
CLASSROOM / IV
TESTING
3-200
EX ELEV
ELEV
BREAKROOM
3-201
STAIR 2
P-502
P-414 P-414
P-101 P-101
ROOF
B07C
FD-C FD-C
3/4" DHW 3/4" DCW
WCO 22
RD-1
P-815 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:2 :5
P
M
PLUMBING DOMESTIC WATER PLANS
SCP 40JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
P-102
N
1/8" = 1'-0"
BASEMENT PLUMBING DOMESTIC WATER PLAN1N
1/8" = 1'-0"
LEVEL 1 PLUMBING DOMESTIC WATER PLAN2
N
1/8" = 1'-0"
LEVEL 2 PLUMBING DOMESTIC WATER PLAN3
N
1/8" = 1'-0"
ROOF PLUMBING DOMESTIC WATER PLAN4
PLUMBING KEYNOTES
1 RELOCATE EXISTING WATER HEATER FROM ROOM B02 TO THE LOCATION SHOWN IN ROOM B07. INSTALL AS CLOSE TO THE NORTH WALL AS POSSIBLE KEEPING ALL THE MANUFATURER'S MAINTENANCE CLEARANCE REQUIREMENTS. DO NOT INSTALL ANY PIPING ABOVE THE ELECTRICAL PANELS AND EQUIPMENT ON THE EAST WALL OF ROOM B07 AND WEST WALL OF ROOM B02, OFFSET PIPING AS REQUIRED. PROVIDE WATER HEATER PAD SIMILAR TO
THE PREVIOUS WATER HEATER PAD IN ROOM B02.
2 REFER TO RISER DIAGRAMS ON SHEET P-301 AND P-302 FOR PIPE SIZES AND ROUTING.
6 ROUTE 1" DOMESTIC COLD WATER PIPE TO THE CARBON FILTER.
7 ROUTE 1" DOMESTIC COLD WATER PIPE FROM THE PUMP SYSTEM UP THROUGH THE PIPE CHASE TO THE SOLO HUMIDIFICATION UNITS IN EACH SPACE.
REFER SHEET M-101 FOR SOLO HUMIDIFICATION UNIT LOCATIONS.
9 HUMIDIFICATION SYSTEM MANUFACTURER IS TO SUBMIT A COMPLETE SYSTEM PIPING LAYOUT TO THE INSTALLING CONTRACTOR PRIOR TO
INSTALLATION.
10 3/4" DCW UP TO ROOF.
No. REVISION DESCRIPTION DATE
Ian.Baxter Image
Ian.Baxter Image
Ian.Baxter Image
Ian.Baxter Image brenden.bond Rectangle brenden.bond
3" SS
3" SS
1 1/2" V
2" SS
1 1/2" V
2" SS
P-528
FD-C
WCO
SP-1
3" SS
1 1/2" V
2" V
3" V
3" SS
3" SS
P502
WCO
3" SS
3" SS
3" SS
4" SS
P-101
FD-C
P-101
FD-C
WCO
P-414
P-414
WCO
P-101
FD-C
P-101
FD-C
P-414
P-414
P-502
4" SS
2" V
4" SS
2" V
2" SS
1/
2" V
2" SS
1/
2" V
2" S
S
1/ 2"
V
4" SS
4" SS
4" S
S
4" S
S
2" SS
1 1/2" V
2" V
2" V
2" V
3" S
S
1/ 2"
V 2"
V
3" V
4" S
S
2" V
2" V
1 1/2" V
4" SS
2" V
4" SS
2" V
2" SS
1/
2" V
1/
2"
V2" SS
3" SS
2" V
4" S
S 2" S
S
1/ 2"
V
3" V
2" V
2" V
3" V th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:2 :5
P
M
PLUMBING WASTE AND VENT RISER
DIAGRAM
SCP 41JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
P-301
NTS
PLUMBING WASTE AND VENT RISER DIAGRAM1
PLUMBING KEYNOTES
10 3/4" DCW UP TO ROOF.
No. REVISION DESCRIPTION DATE brenden.bond Rectangle brenden.bond
1/ 2"
D H
W
3/4" DCW
1/2" DHW
3/4" DCW
1/2" DHW
3/4" DCW
3/4" DHW
3/4" DCW
2" DCW
2" DCW
1 1/4" DHW
2 1/2" DCW
3/4" DHW
3/4" DCW
3/4" DHW
3/4" DCW
1 1/4" DHW
2 1/2" DCW
2 1/2" DCW
2 1/2" DCW
1 1/4" DCW
1/2" DHW
1/2" DCW
3/4" DCW
3/4" DHW
1/2" DHW
1/2" DCW
1" DCW
1" DCW
3/4" DCW
3/4" DHW
2" DCW
1" DCW
1" DCW
1/2" DHW
1/2" DHW
1/2" DCW
1/2" DCW
2 1/2" DCW
1 1/4" DHW
1" DHW
3/4" DCW
2" DCW
3/4" DCW
1/ 2"
D C
W
1/2" DCW
P502
WH-1
P-101
P-101
P-414
P-414
P-101
P-101
P-414
P-414
P-502
P-815
P-528
TO ICE
MACHINE
1" DCW
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:2 :0
P
M
PLUMBING DOMESTIC WATER RISER
DIAGRAM
SCP 42JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
P-302
NTS
PLUMBING DOMESTIC WATER RISER DIAGRAM1
PLUMBING KEYNOTES
10 3/4" DCW UP TO ROOF.
No. REVISION DESCRIPTION DATE brenden.bond Rectangle brenden.bond
TO SAN SEWER
ELEVATOR SUMP
FLOOR
TO BLDG BAS
POWER
SUMP HIGH LEVEL
ON
OFF
HOISTWAY
ELEVATOR
SUBMERSIBLE PUMP
SHUT OFF VALVE
CHECK VALVE
GRATE
MULTI-POINT FLOAT SENSOR
FLOOR
MAXIMUM FLEX CORD LENGTH
6 FEET PER ELECTRICAL
CODE. COORDINATE CONDUIT
ROUTING WITH ELECTRICAL.
NEMA 4X JUNCTION BOX WITH
DISCONNECT. COORDINATE
EXACT HEIGHT WITH DIVISION
26 ELECTRICAL CONTRACTOR
SUMP BASIN (24" x 24" x 24") PER
SPECIFICATION SECTION 221429.
ELEVATOR ESC PUMP
CONTROL PANEL w/
SUMP & SEPARATOR
HIGH LEVEL ALARMS
FLOAT &
THERMOSTATIC TRAP
ASSEMBLY
THERMOMETER
GRAVITY STEAM
CONDENSATE
RETURN
DIELECTRIC
FITTING
NOTES:
1. VERTICAL COIL TYPE DOMESTIC WATER HEATER IS SHOWN. IF HORIZONTAL TUBE BUNDLE TYPE IS FURNISHED, PIPING SHALL BE
SIMILAR.
2. SEE PLUMBING DRAWINGS FOR PIPING CONNECTIONS.
3. PIPING TO UPPER HEATER HEAD SHOULD BE PROVIDED WITH UNION OR FLANGES, LOCATED OUTSIDE THE OUTER DIAMETER OF
HEAD TO FACILITATE REMOVAL OF HEAD AND SHELL.
4. PIPING BETWEEN CONTROL VALVE AND HEATER CONNECTION SHOULD BE AS SHORT AS POSSIBLE.
5. PROVIDE INTEGRAL OR EXTERNAL HEAT TRAPS.
6. PROVIDE HOSE CONNECTION TO DRAIN.
TRAP OR ORIFICED UNION FITTING FURNISHED
BY MANUFACTURER OF DOMESTIC WATER
HEATER, SEE PLUMBING DWGS.
SCALE POCKET
DRAIN FLOOR
DCW
DHWR
CONTROL VALVE BY
MANUFACTURER OF DOMESTIC
WATER HEATER
STEAM SUPPLY LPS
OR MPS
TEMPERATURE & PRESSURE RELIEF VALVE
BY MANUFACTURER OF DOMESTICWATER
HEATER ROUTE TO NEAREST FLOOR DRAIN
PRESSURE GAUGE
D H
W
DOMESTIC WATER
HEATER
M
IN
6"
H E
A T
E R
A B
O V
E
F
LO
O R
, S
P
LU
M B
IN
G
D
R A
W
IN
G S
M
1/4" Ø MOLLY BOLT HOLLOW WALL
ANCHOR (1 EA. SIDE OF LAV)
STEEL WALL PLATE
WALL ANCHOR
STUDS
STEEL HANGER BY LAV MFGR
SECTION A
PLAN
NOTE:
1. AT LAVS WITH FOOT PEDAL CONTROLS PROVIDE AN ADDITIONAL 16 GAGE GALVANIZED
STEELPLATE 12"x16" SECURED TO A MINIMUM OF 2 STUDS PER FOOT PEDAL.
2. PROVIDE 20 GAGE STUDS WHEN HEIGHT EXCEEDS 12'-0".
FOR FIXTURE HEIGHT
SEE ARCHITECTURAL
DRAWINGS
MIN. (3) 1/4" MACHINE
BOLTS W/DOUBLE LOCK
NUTS ON BACK SIDE
MIN. 5 1/4" Ø GALV. MACHINE
BOLTS WELDED TO PLATE
TYP. 1/8"
MINIMUM 16 GAGE GALVANIZED
STEELPLATE 12"x48" MIN. SECURED
TO A MIN. 4 STUDS PER LAVATORY
1/4"
A A
T O
F
LO
O R
3' -3
V A
R
IE
S
HOT PIPECOLD PIPE
REFER TO SPECIFICATIONS FOR INSULATION TYPES, INSULATION
THICKNESSES, HANGER TYPES, HANGER ROD CONNECTIONS TO SRUCTURE
AND HANGER SPACING.
CUT INSULATION TO FIT AROUND
HANGER. SEAL EXPOSED
INSULATION ENDS WITH JOINT
SEALANT.
PROVIDE A SECTION OF HIGH
DENSITY INSULATION OR
STYROFOAM BILLETS AT EACH
HANGER OF COLD INSULATED PIPE.
THREADED STEEL ROD WITH
NUT AND WASHER BOTH
SIDES (TYP.).
CLEVIS HANGER, SHOWN FOR CLARITY.
SIZE HANGER FOR COLD PIPE OUTSIDE
DIAMETER PLUS INSULATION THICKNESS.
DO NOT PENETRATE INSULATION WITHE
HANGER.
CLEVIS HANGER, SHOWN FOR
CLARITY. SIZE HANGER FOR HOT
PIPE OUTSIDE DIAMETER.
SECURE PIPE HANGER TO
STRUCTURE (TYP.)
PROVIDE SHORT INSULATION SHIELD
FOR LAPPING INSULATION JACKET
OVER HIGH DENSITY INSULATION OR
STYROFOAM BILLETS. MAINTAIN
VAPOR BARRIER.
TO MAIN BUILDING
WASTE DRAIN
WATERPROOF SEALANT
SLEEVE THROUGH SLAB
SEALANT BACKING
MATERIAL
FLOOR SLAB
FLOOR DRAIN WITH
TRAP PRIMER ADAPTER
1/2" TRAP PRIMER LINE
DISTRIBUTION UNIT. AVAILABLE FOR 4
ADDITIONAL LINES. PROVIDE ACCESS
PANEL BENEATH LAVATORY.
TRAP PRIMER VALVE
DOMESTIC COLD WATER (DCW) LINE
1/2" TRAP PRIMER SUPPLY SEDIMENT LOOP
NOTE:
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITONS. REFER TO SPECIFICATIONS FOR MORE INFORMATION. PIPE AND CONDUIT OF ALL TRADES MAY BE COMBINED ON THE SAME SUPPORT CHANNEL. COORDINATE SUPPORT CHANNEL LENGTH WITH PIPING AND CONDUIT TO BE SUPPORTED. SUPPORT CHANNEL SPACING SHALL BE DETERMINED BY SMALLEST PIPE TO BE SUPPORTED. CHANNEL SUPPORT MAY BE USED AS A WALL BRACKET, ATTACH TO WALL WITH ANCHOR BOLTS PER SPECIFICATIONS. FOR HORIZONTAL INSULATED PIPING, ATTACH CLAMPS AS INDICATED ABOVE, FOR VERTICAL INSULATED PIPING, ATTACH CLAMPS TO THE PIPE AND SEAL INSULATION AT BOTH CLAMP ENDS
SUPPORT WASHERS AND
LOCKNUTS (TYP.).
UNINSULATED STEEL OR
PLASTIC PIPE.
PROVIDE PLASTIC GALVANIC
ISOLATOR FOR COPPER PIPE
(TYP.)
UNINSULATED COPPER PIPE.
COLD INSULATED PIPE.
PIPE INSULATION (TYP.)
HOT INSULATED PIPE.
PROVIDE 1-5/8"x1-5/8" 14 GA.
CHANNEL SUPPORT.
CUT INSULATION TO FIT AROUND
TRAPEZE HANGER. SEAL BOTH ENDS OF
EXPOSED INSULATION WITH JOINT
SEALANT.
PROVIDE METAL 360° INSULATION SHIELD
AND HIGH DENSITY INSULATION OR PRE-
ENGINEERED THERMAL HANGER-SHIELD
INSERT OF CALCIUM SILICATE
INSULATION. FOR PIPES 4" AND SMALLER,
PRE-ENGINEERED THERMAL HANGER-
SHIELD INSERT OF FLEXIBLE
UNICELLULAR INSULATION MAY BE
PROVIDED.
SIZE AND QUANTITY OF HANGER RODS
PER MANUFACTURER'S
RECOMMENDATIONS.
PROVIDE TWO-PIECE PIPE
CLAMP (TYP.).
PROVIDE A METAL SUPPORT
PLATE WHEN DRAIN IS INSTALLED
IN AN EXISTING FLOOR - CAULK
AROUND DRAIN PRIOR TO RE-
GROUTING
NOTE:
1. SLOPE MEMBRANE LINER 2% TO DRAIN.
THREADED, CAULKED OR NO-HUB
CONNECTION
FLASHING CLAMP
WITH WEEP HOLES
STRUCTURAL SLAB
TILE FLOOR
CONCRETE FILL
NICKLE BRONZE
ADJUSTABLE
STRAINER (FLUSH
WITH FINISHED
FLOOR)
CEMENT BED
LOOSE GRAVEL AT
WEEP HOLES 3mm to 6mm SIZE
WATERPROOF
MEMBRANE
CLAMP WATERPROOF
MEMBRANE INSIDE OF DRAIN
BODY TO DRAIN TO WEEP
HOLES
FINISHED FLOOR
CHROME WALL COVER
AND SCREW
STANDARD 1/8 BEND
PLUGGED TEE WITH
CLEANOUT
NOTE:
1. LOCATE VTR MINIMUM 3'-0" FROM PROPERTY LINE, 10'-0" HORIZONTAL, OR 3'-0" VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, 25'-0" FROM ANY OPENING OR FRESH AIR INTAKE IN MEDICAL FACILITIES AND 1'-0" FROM ANY VERTICAL SURFACE.
2. REFER TO LOCAL CODES FOR OTHER VENT TERMINATION REQUIREMENTS.
3. LOCATE VTR MINIMUM 18" FROM ADJACENT WALL, PARAPET, EXPANSION JOINT, ROOF DRAIN, EQUIPMENT CURB, OR OTHER ROOF FEATURE
4. OFFSET IN CEILING SPACE WHERE REQUIRED TO MEET THESE CONDITIONS.
5. INSULATE LAST 6'-0" OF VENT PIPE INSIDE BUILDING PER SPECIFICATIONS.
COORDINATE INSTALLATION OF
FLASHING AND COUNTERFLASHING
ROOF INSULATION
PROVIDE FIRE STOP SEAL
BETWEEN PIPE AND SLEEVE
OR DECK.
MINIMUM 12" BELOW ROOF
ROOF DECK
CORE DRILL ROOF OR
PROVIDE SLEEVE IF
REQUIRED BY TYPE OF
ROOF DECK.
MINIMUM 12" ABOVE ROOF. EXTEND TO
HEIGHT OF PARAPET WHEN WITHIN 10' OF
PARAPET, OR ABOVE MAXIMUM LOCAL
SNOW DEPTH, WHICHEVER IS HIGHER.
ANCHOR PIPE TO
STRUCTURE.
PROVIDE PIPE INCREASER ON
SMALLER VENT WHERE CODE
REQUIRED MINIMUM VTR IS 3"
OVER 20'
UP TO 20'
155 - 330
NOTE:
1. PROVIDE ACCESS WHERE DEVICES ARE CONCEALED WITHIN PARTITIONS OR ABOVE
CEILINGS. SEE SPECIFICATIONS 22 11 00 - 2.10
NEAREST DOMESTIC WATER
SUPPLY RISER
WATER HAMMER
ARRESTER
DOMESTIC WATER
SUPPLY PIPING TO
FIXTURES
NEAREST DOMESTIC WATER
SUPPLY RISER
WATER HAMMER
ARRESTER
DOMESTIC WATER
SUPPLY PIPING TO
FIXTURES
F
114 - 154E
61 - 113D
33 - 60C
12 - 32B
1 - 11A
FIXTURE UNIT RATINGMARK
WATER HAMMER ARRESTER SCHEDULE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:2 :0
P
M
PLUMBING DETAILS
SCP 43JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
P-501
NTS
ELEVATOR SUMP PUMP DETAIL4 NTS
CONNECTIONS TO DOMESTIC WATER HEATER2 NTS
LAVATORY MOUNTING DETAIL1
NTS
PIPE HANGER DETAIL10
NTS
TRAP PRIMER6 NTS
TRAPEZE PIPE HANGER5
NTS
TYPE "C" FLOOR DRAIN DETAIL3
NTS
TYPICAL INTERIOR WALL CLEANOUT9
NTS
VENT THROUGH ROOF DETAIL7NTS
WATER HAMMER ARRESTOR DETAIL8
No. REVISION DESCRIPTION DATE brenden.bond Rectangle brenden.bond th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF 71
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2012034754 EXP. 12/31/2023
ENGR REG. NO. PE 2014031351 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #:1794.13
/2
/2
:2 :0
P
M
PLUMBING SCHEDULES
SCP 44JRM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
P-601
PLUMBING FIXTURE SCHEDULE
MARK FIXTURE
BASIS OF DESIGN PIPING ROUGH-IN WASTE FIXTURE
UNITS
WATER FIXTURE
UNITS DESCRIPTIONMANUFACTURER MODEL WASTE (IN) VENT (IN) CW (IN) HW (IN)
P-101 Water Closet, Flush Valve, Public American Standard Huron Universal Bowl 4 2 1 - 16 40 Floor mounted-rear outlet, Manual flush valve, elongated bowl. Sloan Regal XL Flushometer 111-1.28 XL. Bemis Commercial Model 1655SSCT open elongated heavy duty plastic.
P-414 Lavatory, Public American Standard Lucerne 2 1-1/2 1/2 1/2 8 8 Straight back, first quality vitreous china with punching for faucet. Set rim 864 mm (34 inches) above finished floor. Faucet - Chicago #895-31. Provide thermostatic tempering valve.
P-502 Service Sink Stern Williams MTB-3624 3 2 3/4 3/4 3 4 Rectangular mop basin, fiat white. Include integral stainless steel drain assembly. Faucet - Chicago #897-CP
P-528 Sink, CRS Elkay LRAD191965PD 2 1-1/2 1/2 1/2 2 2 Single compartment, counter top, self-rimming, 18 Gauge Stainless Steel. Faucet - Chicago #895-31. Provide thermostatic tempering valve.
P-815 Non-Freeze Roof Hydrant Mapa Products MPH-24FP - - 3/4 - 0 0 Cast aluminum weather resistant dome control handle, 304 stainless steel shroud, bronze globe angle valve, quick disconnect with built in vacuum breaker, stainless steel reservoir.
SUMP PUMP SCHEDULE
MARK MANUFACTURER MODEL H.P. MAX FLOW (GPM) MAX HEAD (FT) DISCHARGE SIZE VOLTS/PH FLA
SP-1 Stancor SE-50
FLOOR DRAINS / CLEANOUT SCHEDULE (FD / CO)
MARK DESCRIPTION
BASIS OF DESIGN OUTLET SIZE
(IN)MANUFACTURER MODEL
FD-C Floor Drain Jay R. Smith 2005 Series
WCO Wall Cleanout Jay R. Smith 4530 Series
0.5 74 37 2" 115/1 8
Check Plans
Check Plans
No. REVISION DESCRIPTION DATE brenden.bond Rectangle brenden.bond
| Sheets |
| P-000 - PLUMBING LEGEND, ABBREVIATIONS AND GENERAL NOTES |
| PD101 - PLUMBING WASTE AND VENT DEMOLITION PLANS |
| PD102 - PLUMBING DOMESTIC WATER DEMOLITION PLANS |
| P-101 - PLUMBING WASTE AND VENT PLANS |
| P-102 - PLUMBING DOMESTIC WATER PLANS |
| P-301 - PLUMBING WASTE AND VENT RISER DIAGRAM |
| P-302 - PLUMBING DOMESTIC WATER RISER DIAGRAM |
| P-501 - PLUMBING DETAILS |
| P-601 - PLUMBING SCHEDULES |