Attachment 7 - Architectural - Drawings.pdf
PDF 7 MB Posted
- Attached to
- Y1DA--EHRM Training and Admin Space Support Construction - Kansas City VAMC Federal contract opportunity
- Solicitation number
- 36C77623B0020
About this file
This document package includes architectural drawings and specifications for an EHRM Training and Admin Space Support Construction project at the Kansas City VAMC. The scope of work involves renovations to existing administrative and classroom spaces including demolition, new partitions, flooring, ceilings, lighting, and millwork. The project will upgrade approximately 7,500 square feet of space to support EHRM programs. Renovations will include accessibility improvements, mechanical and electrical system upgrades, new interior finishes, and ADA-compliant signage and wayfinding. Construction is to be completed by June 2023 according to final bid documents. The VA Technology Acquisition Center in Austin is the contracting agency.
View the file
Other files for this federal contract opportunity
Show all 36
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
EXISTING BUILDING 3 FOOTPRINT
BUILDING FOOTPRINT (NOT IN SCOPE
EXISTING LIGHT POST
TEMPORARY BUILDING (NOT IN SCOPE)
SITE PLAN LEGEND
TEMPORARY BUILDING UTITILY
CONNECTION, REF. CIVIL
BLDG 3
T1
T2
T3
T4 32.04
AS001
BUILDING 56
2.012.01
BUILDING 26
2.19
2.18
'-9
/2
1'-6" 5'-6" 1'-6"
32.05
32.02
AS001
6' -2
/2
32.03
32.06
EL. -0.16
EL. 0.00
EL. 0.00
: 2
M
A X
32.07
AS001
22.04
32.08
6"
2.22
KEY PLAN
BUILDING 3
LEVEL 1
0"
LEVEL 2
9'-4"
8"
10° 20°
V E
R T
IC
A
L
PERIMITER FACIA WITH
INTEGRATED GUTTER, BY MFR.
1 1/2" DEEP FLAT DECK, BY MFR.
4" SQUARE BEAMS, BY MFR.
NEW CURB (BEYOND)
REF. CIVIL
4" SQUARE DOWNSPOUT,
ALIGN WITH CANOPY COLUMN
4" SQUARE COLUMN, BY MGF.
NEW CONCRETE
WALKWAY, REF. CIVIL
EXISTING PAVEMENT
TO REMAIN
DOOR ACCESS SWITCH,
REF. ELEC
1/4" / 12"
AS001
EXTEND DOWNSPOUT
TO STREET
ELECTRICAL CONDUIT,
ROUTE UNDERGROUND
AND THROUGH COLUMN
REF. ELEC
LEVEL 1
0"
LEVEL 2
9'-4"
AS001
PERIMITER FACIA WITH
INTEGRATED GUTTER, BY MFR.
WALL MOUNTED LIGHT PACK,
CENTER OVER DOOR, REF. ELEC
NEW CURB, REF. CIVIL
4" SQUARE DOWNSPOUT,
ATTACH TO COLUMN,
MATCH COLUMN ANGLE.
4" SQUARE COLUMN, BY MGF.
NEW CONCRETE
WALKWAY, REF. CIVIL
EXISTING PAVEMENT
TO REMAIN
NEW CANOPY FTG (BEYOND)
EXTEND DOWNSPOUT
TO STREET
RAKE EXISTING MORTAR JOINT 1",
INSERT COUNTER FLASHING AND
HOLD WITH WEDGES
SHEETMETAL FLASHING,
MATCH ROOF FINISH
EXISTING MASONRY
WALL TO REMAIN
CANOPY DECKING, BY MFR.
PERIM. PROFILE W/ INTEGRATED
GUTTER, BY MFR. BEYOND
FILL JOINT WITH SEALANT
LA
P
4" M
IN
SHEETMETAL COUNTERFLASHING,
MATCH ROOF FINISH
STEEL ANGLE ANCHORED TO EXISTING
EXTERIOR WALL, REF: STRUCTURAL
1/4" / 12"
GALVANIZED THREADED ROD
REF: STRUCTURAL
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2009021688 EXP. 12/31/2023
ENGR REG. NO. PE 20190403952 EXP. 12/31/2023
ENGR REG. NO. PE 2018038407 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGIENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/2
/2
:3 :5
A
M
ARCHITECTURAL SITE PLAN
NRL 18 72BKM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
AS001
SPUR #: 1794.13
1" = 20'-0"
SITE PLAN1
N
1/4" = 1'-0" 1/ AE111
ENTRY RAMP PLAN4
KEYNOTE LEGEND
2.01 EXISTING TO REMAIN
2.18 REMOVE EXISTING MECHANICAL EQUIPMENT, REF.
MECHANICAL
2.19 REMOVE EXISTING CONCRETE SLAB, PREP SOIL FOR
SOD, INSTALL NEW SOD.
2.22 EXISTING CURB
22.04 ALUMINUM GUTTER
32.02 NEW ACCESSIBLE WALKWAY, 1:20 MAXIMUM SLOPE,
REF. CIVIL
32.03 NEW CONCRETE LANDING
32.04 APPROXIMATE LOCATION OF TEMPORARY BUILDINGS.
TEMPORARY BUILDING PART OF FUTURE PROJECT
PER SEPARATE CONTRACT.
32.05 NEW CANOPY
32.06 NEW CANOPY SUPPORTS
32.07 NEW CURB CUT, REF. CIVIL
32.08 NEW CURB, REF. CIVIL
N
1/2" = 1'-0" 3/ AS001
SECTION AT SOUTH CANOPY21/2" = 1'-0" 4/ AS001
ELEVATION AT SOUTH CANOPY3
AS0011 1/2" = 1'-0" 2/ AS001
CANOPY / WALL EXPANSION JOINT5
No. REVISION DESCRIPTION DATE brenden.bond Image
UP
DN
DN
UP
UP
DN
DN
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE.
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE CONSTRUCTION
DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL CONSTRUCTION
DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE UTILIZING
HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OR AREA HAS BEEN
INSPECTED BY THE KCVA COR AND INFECTION CONTROL COORDINATOR AND THOROUGHLY
CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES.
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE CAUSED BY HIS
WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND MAINTAIN FLOOR TO
CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR DUE TO EXISTING
CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO ROOMS OUTSIDE OF
SCOPE WITH OWNER.
GENERAL DEMOLITION NOTES
CRAWLSPACE
CS1
CRAWLSPACE
CS2
CRAWLSPACE
CS4
CRAWLSPACE
CS3
CRAWLSPACE
CS5
MECHANICAL
B02
MECHANICAL
B07
MECHANICAL
B01
ELEC
B07A
STAIR 1
2.05
2.06
EXISTING
3-101A
EXISTING
3-101
EXISTING
3-103
EXISTING
3-102
EXISTING
3-104
3-100
EX ELEV MECH
3-106
EX MEN'S
RESTROOMEXISTING BREAK ROOM
3-108
EXISTING
3-110
EXISTING
3-109 EXISTING
3-107
EX ENTRY
3-121
EXISTING
3-111
EXISTING AUDITORIUM
3-112
EXISTING
3-112B
EXISTING
3-112A 3-105
EX WOMEN'S
RESTROOM
3-111A
EX HAC
CLOSET
STAIR 2
STAIR 1
EX ELEV
EXISTING CORRIDOR
3-120 2.09
20'-11 15/16"3'-4" 1'-0 7/8" 13'-9 1/8"
R E
F C
IV
IL
1' -8
M
IN
2.10
2.11
2.11
2.122.122.12
2.13
2.12
2.14 2.14
2.14
2.142.14
2.14
2.14
2.14
2.14
2.14
2.14
2.14
2.14
2.20
EX ELEV STAIR 2
STAIR 1
EXISTING
3-212
EXISTING
3-202
EXISTING
3-204
EXISTING
3-211
EXISTING
3-203
EXISTING
3-201
EXISTING
3-210
EXISTING
3-200
EXISTING
3-201A
EXISTING
3-205
EXISTING
3-207
EXISTING
3-209
EXISTING CORRIDOR
3-208
3-206
EXISTING
SPECIMEN
COLLECTION
3-208
EXISTING
RESTROOM
3'-4" 7'-1 1/8" 3'-4" 27'-0 7/16"
2.11
2.11
2.11
2.14
2.14
2.14
2.142.142.14
2.14
2.142.14
2.14 2.14 2.14
2.14 2.142.14
2.14
2.17
2.17
2.11
2.11
EXISTING WALL CONSTRUCTION TO BE DEMOLISHED IN ITS ENTIRETY
DEMOLITION LEGEND
EXISITNG DOOR & FRAME TO BE DEMOLISHED IN ITS ENTIRETY
EXISITING WINDOW & FRAME TO BE DEMOLISHED IN ITS ENTIRETY
EXISTING WALLS TO REMAIN
EXISTING AREA TO REMAIN (NOT IN SCOPE)
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2009021688 EXP. 12/31/2023
ENGR REG. NO. PE 20190403952 EXP. 12/31/2023
ENGR REG. NO. PE 2018038407 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGIENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/2
/2
:3 :3
A
M
DEMOLITION PLANS
NRL 19 72BKM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
AD011
SPUR #: 1794.13
N
1/8" = 1'-0"
BASEMENT DEMOLITION PLAN1
N
1/8" = 1'-0"
LEVEL 1 DEMOLITION PLAN2
N
1/8" = 1'-0"
LEVEL 2 DEMOLITION PLAN3
KEYNOTE LEGEND
2.05 REMOVE EXISTING CONCRETE WALKWAY TO THE EXTENTS SHOWN
2.06 REMOVE EXISTING DEMOUNTABLE WALL SYSTEM
2.09 REMOVE EXISTING SLIDING DOOR
2.10 REMOVE EXISTING CANOPY IN ITS ENTIRETY
2.11 REMOVE EXISTING WINDOW IN ITS ENTIRETY
2.12 REMOVE EXISTING MILLWORK IN ITS ENTIRETY
2.13 REMOVE EXISTING SINK
2.14 EXISTING FLOOR FINISH TO BE DEMOLISHED
2.17 REMOVE EXISTING LOUVERS
2.20 REMOVE EXISITNG DOOR PANEL, EXISTING FRAME TO REMAIN. REMOVE ALL DOOR
HARDWARE FROM FRAME INCLUDING, BUT NOT LIMITED TO HINGES, LATCH, AND DOOR
CLOSER. PATCH FRAME AS NECESSARY. PAINT FRAME PT-4.
No. REVISION DESCRIPTION DATE
EX ELEV STAIR 2
STAIR 1
8'-0"
9'-0"9'-0"
EXISTING
3-101A
EXISTING
3-101
EXISTING
3-103
EXISTING
3-102
EXISTING
3-104 3-100
EX ELEV MECH
3-106
EX MEN'S
RESTROOM
3-108
EXISTING
BREAK ROOMEXISTING
3-110
EXISTING
3-109
EXISTING
3-107
EX ENTRY
3-121
EXISTING
3-111
3-112
EXISTING
AUDITORIUM
EXISTING
3-112B
EXISTING
3-112A 3-105
EX WOMEN'S
RESTROOM
3-111A
EX HAC
CLOSET
3-120
EXISTING
CORRIDOR
EX ELEV
STAIR 2
OPEN TO
STRUCTURE
EXISTING
3-212
EXISTING
3-202
EXISTING
3-204
EXISTING
3-211
EXISTING
3-203
EXISTING
3-201
EXISTING
3-210
EXISTING
3-200
EXISTING
3-201A
EXISTING
3-205
EXISTING
3-207
EXISTING
3-2093-208
EXISTING
CORRIDOR
3-206
EXISTING
SPECIMEN
COLLECTION
3-208
EXISTING
RESTROOM
STAIR 1
OPEN TO
STRUCTURE
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE.
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE CONSTRUCTION
DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL CONSTRUCTION
DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE UTILIZING
HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OR AREA HAS BEEN
INSPECTED BY THE KCVA COR AND INFECTION CONTROL COORDINATOR AND THOROUGHLY
CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES.
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE CAUSED BY HIS
WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND MAINTAIN FLOOR TO
CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR DUE TO EXISTING
CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO ROOMS OUTSIDE OF
SCOPE WITH OWNER.
GENERAL DEMOLITION NOTES
2' x 2' ACOUSTICAL CEILING, DEMO
2 x 4 EXISTING LIGHT FIXTURE TO REMAIN
2 x 4 EXISTING LIGHT FIXTURE, DEMO
DEMOLITON REFLECTED CEILING PLAN LEGEND
2' x 4' ACOUSTICAL CEILING, DEMO
EXISTING TO REMAIN
1 x 4 EXISTING LIGHT FIXTURE, DEMO
AIR RETURN TERMINAL, DEMO
AIR SUPPLY TERMINAL, DEMO
2' x 4' ACOUSTICAL CEILING, DEMO
1 x 4 EXISTING LIGHT FIXTURE TO REMAIN th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2009021688 EXP. 12/31/2023
ENGR REG. NO. PE 20190403952 EXP. 12/31/2023
ENGR REG. NO. PE 2018038407 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGIENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/2
/2
:3 :3
A
M
REFLECTED CEILING DEMOLITION
PLANS
NRL 20 72BKM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
AD131
SPUR #: 1794.13
N
1/8" = 1'-0"
LEVEL 1 - REFLECTED CEILING DEMOLITION PLAN1
N
1/8" = 1'-0"
LEVEL 2 - REFLECTED CEILING DEMOLITION PLAN2
No. REVISION DESCRIPTION DATE
C 4
FRAMING UNIT SIZE CATEGORY
BASIC PARTITION ASSEMBLY CATEGORY
PARTITION TAG:
BASE
PLAN
HEAD
METAL STUD U-TRACK (TOP AND BOTTOM)
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
WALL FINISH
(REF: ROOM FINISH SCHEDULE)
WIDTH
ACTUAL
5/8"
WIDTH
STUD 5/8"
BASE
PLAN
HEAD
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
WALL FINISH
(REF: ROOM FINISH SCHEDULE)
5/8" GYPSUM BOARD EACH SIDE
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE - (REF: ROOM FINISH SCHEDULE)
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE (REF: ROOM FINISH SCHEDULE)
BATT INSULATION WHERE
SPECIFIED IN SCHEDULE
BASE
PLAN
HEAD
UNDERSIDE OF STRUCTURE
LINE OF CEILING (REF: RCP FOR HEIGHT & TYPE)
WALL FINISH (REF: ROOM FINISH SCHEDULE)
WIDTH
ACTUAL
5/8"
WIDTH
STUD VARIES
WIDTH
STUD 5/8"
5/8" GYPSUM BOARD EACH SIDE
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE - (REF: ROOM FINISH SCHEDULE)
METAL STUD PER SCHEDULE
BATT INSULATION WHERE SPECIFIED
IN SCHEDULE
ACOUSTICAL SEALANT AROUND
PERIMETER (INSULATED WALLS)
ACOUSTICAL SEALANT AROUND
PERIMETER (INSULATED WALLS)
NOTE: INSULATED WALLS AROUND
RESTROOMS EXTEND OUTSIDE LAYER
OF GYPSUM BOARD TO DECK
ACOUSTICAL SEALANT AROUND
PERIMETER (INSULATED WALLS)
WIDTH
STUD5/8"
WIDTH
ACTUAL
BATT INSULATION WHERE
SPECIFIED IN SCHEDULE
DIM DIMDIM DIMDIM DIM
METAL STUD PER SCHEDULE METAL STUD PER SCHEDULE
5/8" GYPSUM WALLBOARD
METAL STUD U-TRACK (TOP AND BOTTOM)
METAL STUD U-TRACK (TOP AND BOTTOM)
BASE
PLAN
HEAD
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
WALL FINISH
(REF: ROOM FINISH SCHEDULE)
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE (REF: ROOM FINISH SCHEDULE)
ACOUSTICAL SEALANT AROUND
PERIMETER (INSULATED WALLS)
WIDTH
STUD5/8"
WIDTH
ACTUAL
BATT INSULATION
DIM DIM
METAL STUD PER SCHEDULE
5/8" GYPSUM WALLBOARD
METAL STUD U-TRACK (TOP AND BOTTOM)
1/2" AIR GAP
1" CONTINUOUS RIGID INSULATION
1. PAINT CONTINUOUS 4" TALL, STENCILED LETTERS, ABOVE CEILING, ON BOTH SIDES OF ALL FIRE AND
SMOKE WALLS DESIGNATING THE PARTITION RATING INDICATED ON THE LIFE SAFETY PLAN.
2. REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR LOCATIONS OF ALL WALL TILE.
PROVIDE AND INSTALL CEMENTITIOUS BACKER BOARD IN LIEU OF GWB AT ALL SCHEDULED TILE LOCATIONS. UNLESS NOTED OTHERWISE, TILE SHALL BE INSTALLED PER TILE COUNCIL OF AMERICA LATEST STANDARDS FOR EACH TYPE OF BACKING MATERIAL REPRESENTED IN WALL/PARTITION.
3. ALL SUSPENDED WALLS AND PARTITIONS SHALL HAVE GWB WHICH EXTENDS A MINIMUM OF 6" ABOVE
THE SUSPENDED CEILING UNLESS SHOWN AND/OR NOTED OTHERWISE BY THE ARCHITECT.
4. REFER TO STRUCTURAL DRAWINGS FOR ALL LOAD BEARING WALL CONDITIONS IN REGARDS TO
STRUCTURAL REQUIREMENTS.
5. "ALIGN" MEANS SIMILAR COMPONENTS OF CONSTRUCTION, E.G. WALLS, JAMBS, ETC. SHALL ALIGN
ACROSS VOIDS AND JOINTS.
6. PARTITIONS SHALL BE CONTINUOUS OVER DOORS SAME ADJACENT WALLS (UNLESS NOTED
OTHERWISE) WHERE DRYWALL CONTINUES ABOVE CEILING AND ABOVE THE CEILING LEVEL UP TO
THE STRUCTURE ABOVE. ALL GYPSUM BOARD RETURNS SHALL HAVE CORNER BEADS MINIMUM
FLOOR TO CEILING. ALL PENETRATIONS IN DRYWALL CONSTRUCTION ABOVE FINISHED CEILING SHALL BE EFFECTIVELY SEALED TO PREVENT SOUND LEAKAGE AND FIRE STOPPING TAPE/CAULK AT ALL
RATED PARTITIONS.
7. ALL MECHANICAL CHASES AND OTHER NOTED CHASES ARE TO EXTEND UP TO THE UNDERSIDE OF THE DECK STRUCTURE ABOVE. ALL PLUMBING CHASES UNLESS OTHERWISE NOTED, SHALL EXTEND
ABOVE THE HIGHEST ADJOINING CEILING AND BE BRACED TO STRUCTURE.
8. ALL CONSTRUCTION DESIGNATED TO BE SUPPORTED BY ROOF STRUCTURE SHALL BE SUPPORTED
BY TOP CHORD OF STRUCTURAL JOISTS AND NOT FROM THE METAL DECK.
9. COORDINATE WITH MILLWORK DRAWINGS FOR PLACEMENT OF BLOCKING IN WALLS/PARTITIONS. ALL
WOOD BLOCKING IS TO BE FIRE RETARDANT TREATED.
10. IMPACT RESISTANT GWB, WHERE NOTED, IS OPTIONAL ABOVE 8' AFF AND BEHIND LOCKERS.
11. SEAL THE TOP AND BOTTOM OF WALL AS WELL AS ALL PENETRATIONS WHERE SMOKE PARTITIONS
ARE DESIGNATED ON THE LIFE SAFETY PLAN TO ELIMINATE THE PASSAGE OF SMOKE.
12. USE DEFLECTION TRACKS WHERE STUD WALLS ATTACH DIRECTLY TO METAL DECK.
GENERAL PARTITION NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2009021688 EXP. 12/31/2023
ENGR REG. NO. PE 20190403952 EXP. 12/31/2023
ENGR REG. NO. PE 2018038407 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGIENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/2
/2
:3 :3
A
M
PARTITION TYPES
NRL 21 72BKM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
AE021
SPUR #: 1794.13
TYPE MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
X3 INSULATED
5/8" GYPSUM BOARD ONE SIDE OF 3 5/8" METAL STUD
AT 16" O.C. W/ BATT INSULATION, OVER 1/2" AIR GAP
AND 1" CONTINUOUS RIGID INSULATION
5 3/4" -
TYPE MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
E3 CARRIER
5/8" GYPSUM BOARD ONE SIDE OF (2) 3 5/8" METAL
STUD AT 16" O.C. WALLS W/ BATT INSULATION BOTH
SIDES
1'-8" 56
TYPE MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
C3 NON-INSULATED
5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD
AT 16" O.C.
4 7/8"
D3 INSULATED
5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD
AT 16" O.C. W/ BATT INSULATION
4 7/8" 38
TYPE MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
A3 NON-INSULATED
5/8" GYPSUM BOARD ONE SIDE OF 3 5/8" METAL STUD
AT 16" O.C.
4 1/4" 27
B3 INSULATED
5/8" GYPSUM BOARD ONE SIDE OF 3 5/8" METAL STUD
AT 16" O.C. W/ BATT INSULATION
4 1/4" 29
No. REVISION DESCRIPTION DATE
UP
UP
DN
DN
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT
WALL UNLESS NOTED OTHERWISE.
2. ALL WALLS ARE TYPE C3 PARTITIONS UNLESS OTHERWISE NOTED. REFER TO PARTITION TYPE
SHEET FOR WALL TYPES.
3. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.
4. REFER TO GLAZING ELEVATIONS & DETAILS SHEET (AE601) FOR WINDOW INFORMATION.
5. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.
6. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW
TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.
7. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.
GENERAL PLAN NOTES
CRAWLSPACE
CS1
CRAWLSPACE
CS2
CRAWLSPACE
CS4
CRAWLSPACE
CS3
CRAWLSPACE
CS5
190 SF
MECHANICAL
B07
206 SF
MECHANICAL
B02
84 SF
MECHANICAL
B01
MECH
B07A
S 1-
G
B
STAIR 1
FEC
AE111
AE201
AE201
AE201
13-111
ADMIN
AE201
56 SF
EX ELEV MECH
3-100
EX ELEV
STAIR 2
STAIR 1
799 SF
CLASSROOM /
IV TESTING
3-112
20 SF
EX HAC
CLOSET
3-111A
34 SF
EX STOR
3-112A
34 SF
EX STOR
3-112B
131 SF
BREAKROOM
3-101
77 SF
EX ENTRY
3-105
192 SF
CONFERENCE
ROOM
3-102
100 SF
TELECOM
3-108
210 SF
ADMIN
3-110
283 SF
ADMIN
3-103
316 SF
ADMIN
3-107
59 SF
MENS RR
3-106
59 SF
WOMENS RR
3-104
3-
3-
E3
CORRIDOR
C1-3-1
3-
2.082.08 2.082.08
AE401
C3 D3
AE40119
FEC
F E
C
D3
AE101
F E
C
AE111
1.02 X3X3
X3 X3
X3X3
X3 X3X3
X3X3
X3
X3
X3
3-111B
3-
3-
S2-1A
3-
2B
3-
2A
3-111E
3-111D
3-
2C 3-
2D
S 1-
1B
S2-1B
3-
1C
3-
1A
3-
3-
5A 3-
5B
S1-1A
12.19
22.08
131 SF
BREAKROOM
3-201
EX ELEV
STAIR 2
STAIR1
245 SF
CLASSROOM /
IV TESTING
3-200
306 SF
CLASSROOM /
IV TESTING
3-210
98 SF
HAC
3-209
237 SF
WAITING
ROOM
3-203
372 SF
CLASSROOM /
IV TESTING
3-211
59 SF
MENS RR
3-208
59 SF
WOMENS RR
3-206
E3
3-
3-
3-
1A
3-
3-
CORRIDOR
C2-3-2 2.082.08
D3D3
AE401
FEC
A3
A3
A3
A3
AE101
AE101
SIM
AE101
SIM
AE101
SIM
AE111
3-
S 1-
3-211B
3-
S2-2
AE101
FIRE - 1 HOUR (NEW/EXISTING)
PARTITION LEGEND
SMOKE (NEW/EXISTING)
EXISTING NON-RATED
WALL TO REMAIN
NEW WALL
BACKER ROD AND SEALANT
EXTEND METAL FRAMING
INTO WINDOW OPENING
1/ 2"
C3
GYPSUM BOARD
APPLY BLACKOUT FILM TO INTERIOR
OF BLOCKED-IN WINDOW PANES
APPLY 7 MIL ANTI-SHATTER FILM TO
INTERIOR OF ALL WINDOW PANES
B3
B3
CENTER FRAMING ON
WINDOW MULLION
FIBERGLASS BATT INSULATION
1'-9" MIN. CLR.
1' -9
M
IN
. C
LR
STEEL FRAMING
5/8" GYPSUM BOARD
A3
A3
EXISTING WALL TO REMAIN
ALIGN WALL WITH WINDOW
JAMB, WHERE OCCURS, REF.
PLANS FOR LOCATIONSX3X3
DUCT, REF. MECH.
STEEL FRAMING
5/8" GYPSUM BOARD
EXISTING WALL TO REMAIN
DUCT, REF. MECH.
BATT INSULATION
A3
X3
A3
D3
X3B3 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2009021688 EXP. 12/31/2023
ENGR REG. NO. PE 20190403952 EXP. 12/31/2023
ENGR REG. NO. PE 2018038407 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGIENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/2
/2
:3 :3
A
M
REFERENCE PLANS
NRL 22 72BKM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
AE101
SPUR #: 1794.13
N
1/8" = 1'-0"
BASEMENT - REFERENCE PLAN1
N
1/8" = 1'-0"
LEVEL 1 - REFERENCE PLAN2
N
1/8" = 1'-0"
LEVEL 2 - REFERENCE PLAN3
KEYNOTE LEGEND
1.02 WALL CENTERLINE TO ALIGN WITH THE CENTERLINE OF WINDOW MULLION
2.08 MATCH INFILLING WALL THICKNESS TO EXISTING WALL
12.19 CEILING MOUNTED CURTAIN AND TRACK
22.08 FLOOR DRAIN, UNDER COUNTER. REF: PLUMBING
1 1/2" = 1'-0" 2/ AE101
PLAN DETAIL AT WINDOW MULLION4
3/4" = 1'-0" 3/ AE101
TYP MECHANICAL CHASE5
3/4" = 1'-0"
RESTROOM EXHAUST CHASE6
No. REVISION DESCRIPTION DATE
UP
UP
UP
DN
DN
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT
WALL UNLESS NOTED OTHERWISE.
2. ALL WALLS ARE TYPE C3 PARTITIONS UNLESS OTHERWISE NOTED. REFER TO PARTITION TYPE
SHEET FOR WALL TYPES.
3. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.
4. REFER TO GLAZING ELEVATIONS & DETAILS SHEET (AE601) FOR WINDOW INFORMATION.
5. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.
6. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW
TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.
7. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.
GENERAL PLAN NOTES
20'-2" FV 25'-0" FV 77'-0" FV 18'-0" FV
140'-2" FV
'-3
/2
F
V
5'-0" FV 9'-0" FV 11'-0" FV
FV
3'-8 1/8" 9'-0" FV 5'-0" FV 9'-0" FV 9'-0" FV 5'-4" FV
FV
5'-0" 7'-11 7/8" FV
29'-4" FV 18'-4" FV 47'-4" FV FV
3'-8 1/2" 9'-0" FV 5'-0" FV 9'-0" FV
2'-7 1/2" FV 2'-0 1/2" FV
9'-0" FV 5'-4" FV 9'-0" FV 7'-3 1/2" FV 9'-4" FV
FV
5'-4"
'-0
F
V 6'
-8
F V
'-1
1/
2" F
V 6'
-8
F V
'-0
F
V
4' -0
F
V
5' -0
F
V
'-0
F V
6' -8
F
V 9'
-7
/2
F V
9'-0" FV
'-0
F
V
7'-5" 7'-5" 20'-5 1/2"
EX ELEV MECH
3-100
EX ELEV
STAIR 2
CLASSROOM /
IV TESTING
3-112
EX HAC
CLOSET
3-111A
EX STOR
3-112A
EX STOR
3-112B
BREAKROOM
3-101
EX ENTRY
3-105
CONFERENCE
ROOM
3-102
TELECOM
3-108
ADMIN
3-110
ADMIN
3-103
ADMIN
3-107
MENS RR
3-106
WOMENS RR
3-104
STAIR1
CORRIDOR
C1-3-1
6' -2
/2
7'
-0
11 1/2"
CRAWLSPACE
CS1
CRAWLSPACE
CS2
CRAWLSPACE
CS4
CRAWLSPACE
CS3
CRAWLSPACE
CS5
MECHANICAL
B07
MECHANICAL
B02
MECHANICAL
B01
MECH
B07A
95'-0" FV
FV
3'-8 1/8" 9'-0" FV 5'-0" FV 9'-0" FV 9'-0" FV
'-0
F
V
29'-4" 18'-4" 47'-4" FVFV
3'-8 1/2" 9'-0" FV 5'-0" FV 9'-0" FV
2'-7 1/2" FV 2'-0 1/2" FV
9'-0" FV
7'-5" 7'-5" 26'-6"
6'-0"
A
LI
G N
BREAKROOM
3-201
CLASSROOM /
IV TESTING
3-200
CLASSROOM /
IV TESTING
3-210
HAC
3-209
CLASSROOM /
IV TESTING
3-211
MENS RR
3-208
WOMENS RR
3-206
EX ELEV
STAIR 2
STAIR1
4'-0" FV
9' -8
F
V
5' -0
" CORRIDOR
C2-3-2
WAITING
ROOM
3-203
11 1/2"
LEVEL 1
0"
LEVEL 2
9'-4"
ROOF
18'-8"
PARAPET
21'-2 3/8"
PROVIDE SLIP-TRACK AT
TOP OF STUD WALL
SCRIBE RIGID INSULATION
AROUND STRUCTURAL JOISTS,
FILL ALL GAPS
AE601
AE601
AE601
EXISTING PLASTER TO REMAIN
5/8" GYPSUM BOARD
3 5/8" METAL STUDS, FILL
WITH FIBERGLASS BATT
INSULATION, REF. PLAN
FINISH & PAINT,
REF. FINISH PLAN
1" RIGID INSULATION
1/2" AIR GAP
7' -1
/4 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2009021688 EXP. 12/31/2023
ENGR REG. NO. PE 20190403952 EXP. 12/31/2023
ENGR REG. NO. PE 2018038407 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGIENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/2
/2
:3 :3
A
M
DIMENSION PLANS
NRL 23 72BKM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
AE111
SPUR #: 1794.13
N
1/8" = 1'-0"
LEVEL 1 - DIMENSION PLAN3
N
1/8" = 1'-0"
BASEMENT - DIMENSION PLAN2
N
1/8" = 1'-0"
LEVEL 2 - DIMENSION PLAN4
KEYNOTE LEGEND
1/2" = 1'-0" 1/ AE101
EXTERIOR WALL FURRING SECTION1
No. REVISION DESCRIPTION DATE
/4
3/8" / 12"
3/4" / 12"3/4" / 12"
1/4" / 12"
/4
3/8
2"
3/8" / 12"
1/4" / 12"
1/4" / 12"
/4
/8
1/8" / 12"
1/4" / 1 2"
1/4" / 12" 1/4" / 12"
/4
/4
7.83
7.837.83
7.837.83
7.837.83
7.837.83
7.83
VP
1" 10'-8 1/2"
8' -6
7.837.83
2.16
5.29
5.30 5.30
5.30
2.01
2.16
23.02
23.02
23.02
23.02
2.16
2.16
1/4" / 12" 1/4" / 12" 1/4" / 12"1/4" / 12"
/4
/4
/4
/4
/4
3"
9' -1
1" 2'
-8
/2
9' -1
1" 2'
-8
/2
T Y
P
2' -6
23.01 23.0123.01
23.01
8' -9
7.64 7.64
7.64
7.64
7.67
5'-0" 6'-10 1/2" 18'-6" 5'-8"
13.11
VP
2.21
AE121
/4
7.64
9' -5
/2
3" 3"
3"
5'-8" 9'-3 1/2" 6'-10 1/2" 3'-7"
3" 3"
3" 3"
3" 3"
3"3"
3' -8
/2
9'
-5
/2
3"
3"
40'-6" 19'-0"
7.93
7.15
7.93
7.15
AE121
AE121
AE111
AE121
5.01
13.12
1/4" / 12"
7.86
5.31
2.07
5.04
23.02
1/4" / 12" ROOF SLOPE
ROOF DRAIN
RD
ROOF LEGEND
VENT PIPE, REF. PLUMBING SETVP
EXHAUST FAN, REF. MECH. SET
NEW MECHANICAL EQUIPMENT,
REF. MECHANICAL SET
ROOFTOP WALKWAY PAD
1. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS AND NOTIFY THE
ARCHITECT, IN WRITING, OF ANY DISCREPANCIES.
2. ALL INFORMATION SHOWN ON THE CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS
AND/OR THE ORIGINAL CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION REGARDING NEW OR REMOVED
EQUIPMENT.
GENERAL ROOF PLAN NOTES
NEW ROOF MEMBRANE
REMOVE EXISTING INSULATION AS
REQUIRED TO INSTALL NEW ROOF CURB.
NEW RIGID INSULATION TO MATCH
DEPTH OF EXISITNG INSULATION
3" X 3" CANT STRIP
3"
NEW SAMF, LAP 4" OVER ROOFING
MEMBRANE, RUN UP SIDE OF MECHANICAL
CURB AND UNDER DRIP EDGE.
4" MIN.
ROOF CURB PER MECHANICAL
EXISTING ROOF STRUCTURE TO REMAIN
EXISTING PARAPET TO REMAIN,
REPAIR ANY DAMAGE TO
ADJACENT SURFACES CAUSED
BY SCUPPER INSTALLATION
NEW CONNECTOR HEAD
WITH 3X4 CUTOUT IN FACE
LOCK SEAM BETWEEN FLANGE
AND CONNECTOR HEAD
FLANGE TO EXTEND ONTO ROOF,
LAP ROOFING OVER FLANGE
FLASH OVER PARAPET WALL
AND FLANGE
NEW DOWNSPOT
BLOCKING AS REQUIRED
8"
NEW ROOF MEMBRANE
REMOVE EXISTING INSULATION AS
REQUIRED TO INSTALL NEW SCUPPER.
NEW RIGID INSULATION TO MATCH
DEPTH OF EXISITNG INSULATION
EXISTING ROOF
STRUCTURE TO REMAIN
EXISTING WALL TO REMAIN,
REPAIR ANY DAMAGE TO
ADJACENT SURFACES CAUSED
BY SCUPPER INSTALLATION
1' -4
1'-0"
2" M
A X
3"
NEW ROOF
MEMBRANE
TPO FLASHING
GALVANIZED RAIN
COWL / AIR GAP
GALVANIZED PIPE SLEEVE
REMOVE EXISTING INSULATION AS
REQUIRED TO INSTALL PIPE COLLAR,
NEW INSULATION TO MATCH DEPTH
OF EXISITNG INSULATION
6" M
IN
.GALVANIZED PIPE
COLLAR
SEAL SEAMS
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2009021688 EXP. 12/31/2023
ENGR REG. NO. PE 20190403952 EXP. 12/31/2023
ENGR REG. NO. PE 2018038407 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGIENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/2
/2
:3 :3
A
M
ROOF PLAN
NRL 24 72BKM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
AE121
SPUR #: 1794.13
N
1/4" = 1'-0"
LEVEL 1 - ROOF PLAN1
KEYNOTE LEGEND
2.01 EXISTING TO REMAIN
2.07 EXISTING ROOF ACCESS LADDER TO REMAIN
2.16 EXISTING ROOF SCUPPER TO REMAIN
2.21 EXISTING ROOF DRAIN TO REMAIN
5.01 STRUCTURAL STEEL. SEE STRUCT. DWG'S
5.04 WALL MOUNTED ROOF ACCESS LADDER
5.29 NEW EXTRUDED ALUMINUM CANOPY SYSTEM WITH INTEGRAL GUTTERS
5.30 NON-PENETRATING STEEL ROOF FALL PROTECTION SYSTEM
5.31 PREFRABRICATED METAL STAIR AND RAILING
7.15 SHEETMETAL DOWNSPOUT, DOWNSPOUT TO CONFORM TO WALL SURFACE, ROUTE AROUND ALL
OBSTRUCTIONS SUCH AS SILLS OR DECORATIVE PROTRUSIONS.
7.64 MANUFACTURED CURB UNDER NEW MECHANICAL EQUIPMENT
7.67 ROOF WALKWAY SURFACE, MASK-OFF WALKWAY EDGES TO EXTENTS INDICATED ON ROOF PLAN
PRIOR TO INSTALLATION OF ADDITIONAL SURFACE AND AGGREGATE TO ENSURE CLEARLY
DEFINED WALKWAY AREAS, COORDINATE FINAL LOCATION WITH VA PRIOR TO INSTALLATION
7.83 LIQUID APPLIED ROOFING RESTORATION, ENTIRE ROOF
7.86 EXPANSION JOINT COVER ASSEMBLY
7.93 8" x 10" THROUGH-WALL SCUPPER
13.11 NEW FALL PROTECTION CAGE.
13.12 COLUMN MOUNTED JIB CRANE, REF: SPECS
23.01 ROOFTOP MECH. EQUIPMENT, REF: MECHANICAL
23.02 MECHANICAL DUCT, REF: MECHANICAL
1 1/2" = 1'-0" 1/ AE121
DETAIL AT ROOF CURB21 1/2" = 1'-0" 1/ AE121
DETAIL AT ROOF SCUPPER36" = 1'-0" 1/ AE121
ROOF DETAIL -TYPICAL PIPE PENTRATION4
No. REVISION DESCRIPTION DATE
2' x 4' ACOUSTICAL CEILING GYPSUM BOARD CEILING
CEILING HEIGHT,
ABOVE FINISH FLOOR
2' x 4' LIGHT FIXTURE
REF: ELECTRICAL
00'-00"
REFLECTED CEILING PLAN LEGEND
RETURN AIR GRILLE,
REF: MECH
VRF CASSETTE, REF: MECH
EXHAUST AIR GRILLE
REF: MECH
2 x 2 LIGHT FIXTURE
REF: ELECTRICAL
EXISTING TO REMAIN
SENSOR
REF: ELECTRICAL
EXIT LIGHT / SIGN
WALL-MOUNTED EXT LIGHT,
9'-0" AFF. REF. ELECTRICAL
NEW SMOKE DETECTOR -
SPOT TYPE
S
6" x 4' LIGHT FIXTURE
REF: ELECTRICAL
1. ALL CEILINGS 8'-0" A.F.F. U.N.O.
2. ALL SURFACES OF FURRDOWNS TO BE PAINTED P1 U.N.O.
3. PROVIDE HOLD DOWN CLIPS AT VESTIBULES AND AREA NEAR EGRESS DOORS.
GENERAL REFLECTED CEILING PLAN NOTES
9'-0"
AE131
EX ELEV MECH
3-100
CLASSROOM /
IV TESTING
3-112
EX HAC
CLOSET
3-111A
EX STOR
3-112A
EX STOR
3-112B
BREAKROOM
3-101
EX ENTRY
3-105
CONFERENCE
ROOM
3-102
TELECOM
3-108
ADMIN
3-110
ADMIN
3-103
ADMIN
3-107
MENS RR
3-106
WOMENS RR
3-104
EX ELEV STAIR 2
STAIR1
E Q
E Q
EQ EQEQ EQ
E Q
E Q
ADMIN
3-111
OPEN TO
STRUCTURE
OPEN TO
STRUCTURE
E Q
E Q
12.19
7'-6"
AE111
32.05
32.0632.06
9'-0"
E Q
E Q
E Q
EQ
1'-0"
2' -0
EQEQ
EQ EQ
E Q
E Q
7'-2 1/2"
7'-2 1/2"
7'-10"
7'-10"
7'-10"
7'-10"
7'-2 1/2"
7'-10"
7'-10"
7'-10"
EQ
7'-2 1/2"
7'-2 1/2"
AE131
AE131
AE131
AE131
S 23.04
23.04
23.04 7'-10"
CLASSROOM /
IV TESTING
3-210
CLASSROOM /
IV TESTING
3-200
WOMENS RR
3-206
MENS RR
3-208 EX ELEV STAIR 2
HAC
3-209
WAITING
ROOM
3-203
BREAKROOM
3-201
CLASSROOM /
IV TESTING
3-211
CORRIDOR
C2-3-2
OPEN TO
STRUCTURE
E Q
E Q
EQ EQEQ EQ
E Q
E Q
E Q
E Q
AE111
STAIR1
E Q
E Q
EQ EQ
E Q
E Q
EQ EQ
E Q
E Q
EQEQ E
Q
E Q
6' -4
7'-2 1/2"
7'-10"
7'-2 1/2"
7'-2 1/2"
7'-2 1/2"
7'-2 1/2"
S
AE131
AE131
AE131
AE131
AE131
AE131
GYPSUM BOARD ON
METAL STUD FRAMING
ACOUSTIC CEILING
AS SCHEDULED
M
IN6"
M
IN6"
2"
PER PLAN
P E
R P
LA
N
GYPSUM BOARD ON
METAL STUD FRAMING
ACOUSTIC CEILING
AS SCHEDULED
M
IN6"
4 7/8"
P E
R P
LA
N
2"
M
IN6"
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2009021688 EXP. 12/31/2023
ENGR REG. NO. PE 20190403952 EXP. 12/31/2023
ENGR REG. NO. PE 2018038407 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGIENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/2
/2
:3 :3
A
M
REFLECTED CEILING PLANS
NRL 25 72BKM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
AE131
SPUR #: 1794.13
N
1/8" = 1'-0"
LEVEL 1 - REFLECTED CEILING PLAN2
N
1/8" = 1'-0"
LEVEL 2 - REFLECTED CEILING PLAN3
1 1/2" = 1'-0" 2/ AE131
CEILING SECTION - ACT TO GYP HEADER1
KEYNOTE LEGEND
12.19 CEILING MOUNTED CURTAIN AND TRACK
23.04 WALL MOUNTED MECH. EQUIPMENT, REF: MECHANICAL
26.04 WALL MOUNTED LIGHT FIXTURE, REF: ELEC
32.05 NEW CANOPY
32.06 NEW CANOPY SUPPORTS
No. REVISION DESCRIPTION DATE
1 1/2" = 1'-0" 2/ AE131
CEILING SECTION - ACT TO GYP HEADER 24
LEVEL 1
0"
LEVEL 2
9'-4"
ROOF
18'-8"
PARAPET
21'-2 3/8"
32.06
5.29
5.30
13.11
5 5
5 5
23.0123.0123.0123.01
2.07
5.31
26.04
5.04
23.05
LEVEL 1
0"
LEVEL 2
9'-4"
ROOF
18'-8"
PARAPET
21'-2 3/8"
5.30
'-3
5.29
32.06
5.01
13.12
13.11
LEVEL 1
0"
LEVEL 2
9'-4"
ROOF
18'-8"
PARAPET
21'-2 3/8"
5.30
5.29
8.948.94
13.11
6" 6"
7.15
7.18 7.15
7.18
8.95
8.952.01
2.16
5.01
23.01
23.01 23.01 23.01
13.10 5.31
26.04
EQEQ
5.04
LEVEL 1
0"
LEVEL 2
9'-4"
ROOF
18'-8"
PARAPET
21'-2 3/8"
5.30
13.11
2.07
13.12
5.01
5.04
WINDOW TAG, REF. 12/AE601
ELEVATION LEGEND
3A th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2009021688 EXP. 12/31/2023
ENGR REG. NO. PE 20190403952 EXP. 12/31/2023
ENGR REG. NO. PE 2018038407 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGIENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/2
/2
:3 :4
A
M
BUILDING ELEVATIONS
NRL 26 72BKM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
AE201
SPUR #: 1794.13
1/8" = 1'-0" 2/ AE101
BUILDING ELEVATION - WEST3
1/8" = 1'-0" 2/ AE101
BUILDING ELEVATION - SOUTH1
KEYNOTE LEGEND
2.01 EXISTING TO REMAIN
2.07 EXISTING ROOF ACCESS LADDER TO REMAIN
2.16 EXISTING ROOF SCUPPER TO REMAIN
5.01 STRUCTURAL STEEL. SEE STRUCT. DWG'S
5.04 WALL MOUNTED ROOF ACCESS LADDER
5.29 NEW EXTRUDED ALUMINUM CANOPY SYSTEM WITH INTEGRAL GUTTERS
5.30 NON-PENETRATING STEEL ROOF FALL PROTECTION SYSTEM
5.31 PREFRABRICATED METAL STAIR AND RAILING
7.15 SHEETMETAL DOWNSPOUT, DOWNSPOUT TO CONFORM TO WALL SURFACE, ROUTE
AROUND ALL OBSTRUCTIONS SUCH AS SILLS OR DECORATIVE PROTRUSIONS.
7.18 PRECAST SPLASH BLOCK
8.94 7 MIL ANTI-FRAGMENTATION FILM APPLIED TO ALL WINDOW PANES
8.95 BLACKOUT FILM APPLIED TO WINDOW PANES
13.10 COLUMN MOUNTED JIB CRANE
13.11 NEW FALL PROTECTION CAGE.
13.12 COLUMN MOUNTED JIB CRANE, REF: SPECS
23.01 ROOFTOP MECH. EQUIPMENT, REF: MECHANICAL
23.05 EXHAUST FAN. REF: MECHANICAL
26.04 WALL MOUNTED LIGHT FIXTURE, REF: ELEC
32.06 NEW CANOPY SUPPORTS
1/8" = 1'-0" 2/ AE101
BUILDING ELEVATION - EAST4
1/8" = 1'-0" 2/ AE101
BUILDING ELEVATION - NORTH2
No. REVISION DESCRIPTION DATE
AE401 9
AE4013
WOMENS RR
3-104
MENS RR
3-106
3-
3-
E3 D3
D3
4 8.95
X3 X3
MENS RR
3-208
WOMENS RR
3-206
AE40115 AE401 1311
3-
3-
E3 D3 D3
2.08
B3 X3 X3
PCT-1
GB1
GB2
GB3
SD1
SN1
PTD1
M1
TP1
PCT-1
PT-1
C A
P W
IT
H
S C
H
LU
T E
R S
C H
E
IN
E
6' -0
GB1
GB2
GB3
SN1
TP1
PCT-1
PT-1
C A
P W
IT
H
S C
H
LU
T E
R S
C H
E
IN
E
6' -0
SN1
C A
P W
IT
H
S C
H
LU
T E
R S
C H
E
IN
E
6' -0
PCT-1
PT-1
PCT-1
PT-1
C A
P W
IT
H
S C
H
LU
T E
R S
C H
E
IN
E
6' -0
PCT-1
PT-1
GB1
GB2
TP1
PCT-1
GB2
TP1
GB1
M1
PTD1
SD1
PCT-1
PT-1
C A
P W
IT
H
S C
H
LU
T E
R S
C H
E
IN
E
6' -0
PCT-1
GB1
GB2
SD1
TP1
SN1
PTD1
M1
C A
P W
IT
H
S C
H
LU
T E
R S
C H
E
IN
E
6' -0
PCT-1
PT-1
GB1
GB2
SN1
TP1
GB3
PCT-1
PCT-2
PT-1
C A
P W
IT
H
S C
H
LU
T E
R S
C H
E
IN
E
6' -0
PCT-1
PT-1
C A
P W
IT
H
S C
H
LU
T E
R S
C H
E
IN
E
6' -0
PCT-1
PCT-2
PT-1
C A
P W
IT
H
S C
H
LU
T E
R S
C H
E
IN
E
6' -0
PCT-1
PT-1
GB1
TP1
GB1
GB3
C A
P W
IT
H
S C
H
LU
T E
R S
C H
E
IN
E
6' -0
PCT-1
SD1
PTD1
M1
GB2
GB3
GB1
TP1
PCT-1
PT-1
C A
P W
IT
H
S C
H
LU
T E
R S
C H
E
IN
E
6' -0
" F R
ID
G
E C
A B
IN
E
T
A
LI
G N
W
IT
H A
B O
V E
EQ
3'-0" CLEAR
RB-1
PCT-1
PLAM-1
PLAM-1
SSM-1
HEIGHT/WIDTH OF REFRIGERATOR
PLUS MANUFACTURERS
RECOMMENDED CLEARANCES
FILLER PANEL
(TYP)
2'-3"
AE601
AE601
AE601
1' -3
"K4665
R6200
R4650
1. REFER TO FINISH FLOOR PLANS SHEET (AF701) AND FINISH SCHEDULE SHEET (AF711)
FOR FINISH INFORMATION.
2. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.
3. REFER TO GLAZING ELEVATIONS & DETAILS SHEET (AE611) FOR WINDOW INFORMATION.
GENERAL INTERIOR ELEVATION NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR 2009021688 EXP. 12/31/2023
ENGR REG. NO. PE 20190403952 EXP. 12/31/2023
ENGR REG. NO. PE 2018038407 EXP. 12/31/2023
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY-SPRINKLERED
INDUSTRIAL HYGIENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/2
/2
:3 :4
A
M
ENLARGED PLANS AND INTERIOR
ELEVATIONS
NRL 27 72BKM
FINAL BID DOCUMENTS
EHRM TRAINING & ADMIN
SUPPORT
06/28/2022
589-21-702
VA MEDICAL CENTER
4801 LINWOOD BLVD
KANSAS CITY, MO 64128
AE401
SPUR #: 1794.13
N
1/2" = 1'-0"
LEVEL 1 - ENLARGED PLAN1
N
1/2" = 1'-0"
LEVEL 2 - ENLARGED PLAN2
3/8" = 1'-0"
3-104 WOMENS RR NORTH ELEVATION33/8" = 1'-0"
3-104 WOMENS RR EAST ELEVATION43/8" = 1'-0"
3-104 WOMENS RR SOUTH ELEVATION53/8" = 1'-0"
3-104 WOMENS RR WEST ELEVATION6
3/8" = 1'-0"
3-106 MENS RR NORTH ELEVATION73/8" = 1'-0"
3-106 MENS RR EAST ELEVATION83/8" = 1'-0"
3-106 MENS RR SOUTH ELEVATION93/8" = 1'-0"
3-106 MENS RR WEST ELEVATION10
3/8" = 1'-0"
3-202 WOMENS RR NORTH ELEVATION113/8" = 1'-0"
3-202 WOMENS RR EAST ELEVATION123/8" = 1'-0"
3-202 WOMENS RR SOUTH ELEVATION133/8" = 1'-0"
3-202 WOMENS RR WEST ELEVATION14
3/8" = 1'-0"
3-204 MENS RR NORTH ELEVATION153/8" = 1'-0"
3-204 MENS RR EAST ELEVATION163/8" = 1'-0"
3-204 MENS RR SOUTH ELEVATION173/8" = 1'-0"
3-204 MENS WEST ELEVATION18 3/8" = 1'-0"
3-101 BREAKROOM ELEVATION19
KEYNOTE LEGEND
2.08 MATCH INFILLING WALL THICKNESS TO EXISTING WALL
8.95 BLACKOUT FILM APPLIED TO WINDOW PANES
SCHEDULE OF ACCESSORIES
ABBREVIATION DESCRIPTION PROVIDED BY INSTALLED BY
F-2 F2
F-4 F3
GB1 36" TOILET STALL GRAB BAR CONTRACTOR CONTRACTOR
GB2 42" TOILET STALL GRAB BAR CONTRACTOR CONTRACTOR
GB3 18" TOILET STALL GRAB BAR CONTRACTOR CONTRACTOR
K4665 MICROWAVE VA VA
M1 SURFACE MOUNTED MIRROR CONTRACTOR CONTRACTOR
PTD1 SURFACE MOUNTED PAPER TOWEL DISPENSER CONTRACTOR CONTRACTOR
R4650 ICE MAKER W/ DISPENSER VA VA
R6200 REFRIGERATOR VA VA
SD1 SURFACE MOUNTED SOAP DISPENSER VA VA
SN1 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL CONTRACTOR CONTRACTOR
TP1 SURFACE MOUNTED TOILET PAPER DISPENSER CONTRACTOR CONTRACTOR
REFER GI001 - GENERAL INFORMATION FOR MOUNTING LOCATIONS
No. REVISION DESCRIPTION DATE
F
SCHED. DIM.
S C
H E
D . D
IM
SCHED. DIM.
S C
H E
D . D
IM
SCHED. DIM.SCHED. DIM.
S C
H E
D . D
IM
S C
H E
D . D
IM
.2' -0
4'
-0
V A
R
IE
S 6"
4"
4' -0
2'
-6
6" VARIES 6" 6" VARIES 6"
FFE
NL HL FL
FULL LITEHALF LITENARROW LITEFLUSH
SCHED. DIM.
S C
H E
D . D
IM
1' -0
6" VARIES 6"
LV
LOUVERED VENT
- TEMPERED GLAZING
1' -0
6" VARIES 6"
HM-1
2" S
C H
E D
. D
IM
2"
DIM.
SCHED. 2"
FFE
STANDARD FRAME
INTERIOR DETAILS:
HEAD:
JAMB:
/2 AE601
/1 AE601
A
2" 5/
8"
1 15/16" VARIES 1 9/16"
1/2"
INT. STUD WALLS
WALL THICKNESS AT 1/2"
RE: DOOR SCHEDULE
FRAME DEPTH
HOLLOW METAL FRAME AS
SCHEDULED
DOOR AS SCHEDULED
PARTITION PER PLAN
SEALANT CONTINUOUS, TYP.
HOLLOW METAL FRAME AS
SCHEDULED
JAMB ANCHOR
DOOR AS SCHEDULED
SEALANT EACH SIDE (TYP.)
DOUBLE STUDS BACK TO BACK
PARTITION PER PLAN
U.N.O.
4"TYP.
ADJACENT WALL
4'-0 7/8" FV
2' -0
F
V
4"
3' -9
/2
F
V E Q
E Q 3' -9
/2
F
V E Q
E Q
4'-0" FV 9'-8" FV
4" EQ EQ EQ
1 2 3 4
3'-4" FV
3' -9
/2
F
V E Q
E Q
LAMINATED GLASS AT
PANES LOWER THAN 12'
ABOVE GRADE
9'-0" FV
3' -9
/2
F
V
EQ EQ EQ
E Q
E Q
TYPICAL WINDOW FRAME DETAILS:
HEAD:
JAMB:
SILL:
/10 AE601
/3 AE601
/7 AE601
INTERIOR
EXISTING PLASTER TO REMAIN
EXISTING EXTERIOR BRICK TO REMAIN
5/8" GYPSUM BOARD
3 5/8" METAL FURRING, FILL
WITH FIBERGLASS BATT
INSULATION, REF. PLAN
WRAP 5/8" GYPSUM BOARD
AROUND HEAD & JAMBS
BENT METAL FLASHING
BACKER ROD & CAULK
NEW WINDOW FRAME
AND RECEPTOR
CAULK AROUND ALL FRAMES,
FLASHING & BETWEEN
RECEPTOR AS SPECIFIED BY
WINDOW MANUFACTURER
METAL DRYWALL CORNER
@ HEAD AND JAMBS
FINISH & PAINT, REF. FINISH PLAN
EXTERIOR
EXISTING CONCRETE LINTEL
TO REMAIN, PROTECT
STONE AROUND OPENING
DURING CONSTRUCTION
EXISTING
MATCH
COMPOSITE OR METAL
BLOCKING AS NEEDED
1" 1/2" 3 5/8" 5/8"
1" RIGID INSULATION
1/2" AIR GAP
OCCURS AT NEW WINDOWS ONLY,
REF. PLANS & ELEVATIONS FOR
LOCATIONS
BACKER ROD & CAULK
FILL VOIDS WITH
RIGID INSULATION
EXISTING
MATCH
INTERIOR
EXISTING PLASTER TO REMAIN
5/8" GYPSUM BOARD
3 5/8" METAL FURRING, FILL
WITH FIBERGLASS BATT
INSULATION, REF. PLAN
WRAP 5/8" GYPSUM BOARD
AROUND HEAD & JAMBS
METAL DRYWALL CORNER
@ HEAD AND JAMBS
FINISH & PAINT, REF. FINISH PLAN
1" RIGID INSULATION
1/2" AIR GAP
BACKER ROD & CAULK
FILL VOIDS WITH
RIGID INSULATION
EXISTING EXTERIOR
BRICK TO REMAIN
BACKER ROD & CAULK
NEW WINDOW FRAME
AND RECEPTOR
CAULK AROUND ALL FRAMES,
FLASHING & BETWEEN
RECEPTOR AS SPECIFIED BY
WINDOW MANUFACTURER
EXTERIOR
COMPOSITE OR METAL
BLOCKING AS NEEDED
OCCURS AT NEW WINDOWS ONLY,
REF. PLANS & ELEVATIONS FOR
LOCATIONS
1" 1/2" 3 5/8" 5/8"
BACKER ROD & CAULK
3/4" THICK SOLID SURFACE SILL
INTERIOREXTERIOR
EXISTING
MATCH
EXISTING EXTERIOR BRICK TO REMAIN
BACKER ROD & CAULK
NEW WINDOW FRAME
AND RECEPTOR
CAULK AROUND ALL FRAMES,
FLASHING & BETWEEN
RECEPTOR AS SPECIFIED BY
WINDOW MANUFACTURER
EXISTING CONCRETE LINTEL
TO REMAIN, PROTECT
STONE AROUND OPENING
DURING CONSTRUCTION
COMPOSITE OR METAL
BLOCKING AS NEEDED
OCCURS AT NEW WINDOWS ONLY,
REF. PLANS & ELEVATIONS FOR
LOCATIONS
EXISTING PLASTER TO REMAIN
5/8" GYPSUM BOARD
3 5/8" METAL FURRING, FILL
WITH FIBERGLASS BATT
INSULATION, REF. PLAN
FINISH & PAINT, REF. FINISH PLAN
1" 1/2" 3 5/8" 5/8"
1" RIGID INSULATION
1/2" AIR GAP
5/8"
BACKER ROD & CAULK
1'-5" MIN
8" MIN
9"
SINK AND FAUCET
LINE OF END-OF-UNIT BULKHEAD
WHERE OCCURS
PLASTIC LAMINATE VENEER ON 3/4" PLYWOOD
(MARINE GRADE IN WET AREAS) APRON -
PLASTIC LAMINATE AT ALL EXPOSED EDGES
EXTEND APRON TO 2'-3" (TRIM TO FIT
LAVATORY/SINK IF NEEDED AND FINISH
EDGE WITH SCHEDULED LAMINATE)
6" 11" MIN
PLASTIC LAMINATE VENEER ON 3/4"
MARINE GRADE PLYWOOD. ATTACH
WITH CONCEALED KEKU
SUSPENSION FITTING BY HAFELE
(TWO EACH SIDE) OR EQUAL
CONTROLS
3/4" MARINE GRADE PLYWOOD
AS A SUBSTRATE, BLOCKING OR
BULKHEADS (TYPICAL) (PLASTIC
LAMINATE COVERED WHEN
VISIBLE)
WALL CLEAT/BLOCKING FOR
BULKHEAD (AS REQUIRED)
LINE OF INTERMEDIATE OR END-
OF-UNIT BULKHEAD WHERE
OCCURS
NOTE:
UNLESS OTHERWISE NOTED,
THE CONTRACTOR IS TO
DETERMINE THE NUMBER AND
LOCATIONS OF INTERMEDIATE
BULKHEADS REQUIRED TO
SUPPORT THE VANITY UNIT
2' -1
0"
7"
SCHEDULED WALL TILE
SCHEDULED
BASE
2'-0"
1/
2"
1/4" MEDIUM DENSITY
PARTICLEBOARD DRAWER
BOTTOMS
1/2" PLYWOOD (OR MEDIUM
DENSITY PARTICLEBOARD)
DRAWER SIDES
1/4" MEDIUM DENSITY
PARTICLEBOARD
IN-LINE HOLES AND SHELF
SUPPORTS
3/4" PLYWOOD (OR MEDUIM
DENSITY PARTICLEBOARD) WITH
1/16" PLASTIC LAMINATE EDGE
BAND
3/4" X 1 1/2" BLOCKING
(TYPICAL)
2X BLOCKING (TYPICAL)
1/2" SOLID SURFACE TOP ON
3/4" PLYWOOD (MARINE
GRADE AT WET AREAS)
WHITE MELAMINE VENEER ON
ALL INTERIOR SURFACES
(TYPICAL)
PLASTIC LAMINATE VENEER ON
FACE AND EDGES OF 3/4" PLYWOOD
(OR MEDIUM DENSITY
PARTICLEBOARD) TYP
SCHEDULED BASE
SCHEDULED FLOORING
3/4" PLYWOOD (OR MEDUIM
DENSITY PARTICLEBOARD)
ADJUSTABLE SHELF WITH 1/16"
PLASTIC LAMINATE EDGE BAND
2'-0"
7" 4"
2' -1
0"
1/4"
TYP
1/8"
SCHEDULED WALL TILE TILE
PLASTIC LAMINATE VENEER ON
FACE OF 3/4" X 1 1/2" BLOCKING
(TYPICAL)
1/
2"
3/4" PLYWOOD (OR MEDUIM DENSITY
PARTICLEBOARD) WITH PLASTIC
LAMINATE VENEER AT EDGE BAND
1/2" PLYWOOD (OR MEDIUM
DENSITY PARTICLEBOARD)
DRAWER SIDES
PLASTIC LAMINATE VENEER ON
EDGE OF CABINET BOX FRAME
(TYPICAL)
3/4" PLYWOOD (OR MEDIUM
DENSITY PARTICLEBOARD)
ADJUSTABLE SHELF)
PLASTIC LAMINATE VENEER ON FACE
(AT ALL EXPOSED/VISIBLE EXTERIOR
SURFACES (TYPICAL) AND EDGES OF
3/4" PLYWOOD (OR MEDIUM DENSITY
PARTICLEBOARD)
3/4" X 1 1/2" BLOCKING
IN-LINE HOLES AND SHELF
SUPPORTS
1/4" MEDIUM DENSITY
PARTICLEBOARD
WHITE
MELAMINE
VENEER ON
ALL INTERIOR
SURFACE
(TYPICAL)
1'-1"
SCHEDULED WALL TILE
R E
F E
R E
LE
V
A T
IO
N
3/4" X 1 1/2" BLOCKING WITH
PLASTIC LAMINATE VENEER
ACOUSTICAL CEILING TILE
M
IN6"
1'-4"
R E
F E
R E
N C
E E
LE
V
A T
IO
N
PLASTIC LAMINATE VENEER ON FACE
(AT ALL EXPOSED/VISIBLE EXTERIOR
SURFACES (TYPICAL) AND EDGES OF
3/4" PLYWOOD (OR MEDIUM DENSITY
PARTICLEBOARD)
1. FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF MILLWORK.
2. COORDINATE LOCATION OF RECEPTACLES WITH ELECTRICAL DRAWINGS.
3. WHERE FURR DOWNS ARE CALLED FOR OVER UPPER CABINETS, EXTEND
FURR DOWN 1" MIN. PAST FRONT EDGE OF MILLWORK - TYPICAL.
4. NO PLASTIC HARDWARE, BRACKETS OR CLIPS WILL BE ACCEPTED.
5. ALL DRAWERS…
This is the start of the file's text. The full file is on GovTribe.