This document package includes a plumbing plans and specifications document and a related federal contract opportunity notice. The plumbing plans and specifications document provides details for a project to expand building 32 at the Tomah VA Medical Center in Wisconsin to incorporate a new 5,000 square foot data center. It includes plumbing drawings, schedules, notes, diagrams and specifications. The related federal contract opportunity is a solicitation from the Department of Veterans Affairs Technology Acquisition Center Austin seeking a general contractor to provide labor, materials and equipment to complete the building expansion and address other facility needs in accordance with the specifications and drawings. The estimated project value is over $5 million.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATIONS
F FAHRENHEIT
FCO FLOOR CLEANOUT
FCW FILTERED COLD WATER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FM FLOW METER
FS FLOOR SINK
FS FLOW SWITCH
FU FIXTURE UNITS
N2 NITROGEN
N20 NITROUS OXIDE
NC NORMALLY CLOSED
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM. NOMINAL
NPW NON POTABLE WATER
NTC NOT TO SCALE
O2 OXYGEN
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OR OPERATING ROOM
OVFL OVERFLOW
GAL GALLON
GCO GRADE CLEANOUTS
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GRS GAS REGULATOR STATION
GT GREASE TRAP
GVTR GAS VENT THROUGH ROOF
GWH GAS FIRED WATER HEATER
RD ROOF DRAIN
RDL ROOF DRAIN LEADER
RL ROOF LEADER
RO REVERSE OSMOSIS WATER
ROR REVERSE OSMOSIS RETURN
ROS REVERSE OSMOSIS SUPPLY
RWL RAIN WATER LEADER
UPC UNIFORM PLUMBING CODE
YCO YARD CLEANOUT
YH YARD HYDRANT
X
X
LEGEND
DOMESTIC HOT WATER, HOT WATER
DOMESTIC COLD WATER, COLD WATER
ST
SANITARY SEWERSAN BOTTOM CONNECTION, 45° OR 90°
TOP CONNECTION, 45° OR 90°
RISE OR DROP IN PIPE
CAPPED OUTLET
PRESSURE GAGE
THERMOMETER
STRAINER
FLOW ELEMENTFE
HOSE BIB
BALL VALVE
GATE VALVE WITH 3/4 " HOSE ADAPTER
CHECK VALVE
ANGLE GLOBE VALVE
BUTTERFLY VALVE
TWO POSITION CONTROL VALVE
ISOLATION VALVE (BALL OR GATE)
MANUAL AIR VENT
TEST PLUG (PRESSURE/TEMPERATURE)
GLOBE VALVE
PRESSURE REGULATING VALVE
THREE-WAY TWO POSITION CONTROL VALVE
AUTOMATIC AIR VENTAV
GENERAL NOTES
VENT
WATER HAMMER ARRESTOR
VENT, BELOW GRADE
EL ELEVATION
EPA ENVIROMENTAL PROTECTION AGENCY
ESC ESCUTCHEON
ESH EMERGENCY SHOWER
ET EXPANSION TANK
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EWS EYE WASH STATION
EX EXISTING
DCW DOMESTIC COLD WATER
DFU DRAINAGE FIXTURE UNITS
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RETURN
DHWR DOMESTIC WATER RETURN
DHWS DOMESTIC HOT WATER SUPPLY
DI DEIONIZED WATER
DN DOWN
DOE DEPARTMENT OF ENERGY
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DWH DOMESTIC WATER HEATER
DWR DRINKING WATER RETURN
DWS DRINKING WATER SUPPLY
DWV DRAIN WASTE VENT
C CELSIUS
CA COMPRESSED AIR
CGA COMPRESSED GAS ASSOCIATION
CI CASTIRON
CO CLEANOUT
CS CLINICAL SINK
CV CONTROL VALVE
CW COLD WATER
BFP REDUCED PRESSURE BACKFLOW PREVENTER
BHP BREAK HORSEPOWER
BT BATHTUB
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
A/E ARCHITECT / ENGINEER
ACW AUTOMATIC CART WASH
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISH GRADE
AG AIR GAP
AP ACCESS PANEL
AS AUTOMATIC SPRINKLER
ASD ADJUSTABLE SPEED DRIVES
ASD AUTOMATIC SPRINKLER DRAIN
ASR AUTOMATIC SPRINKLER RISER
AV ACID VENT
AW ACID WASTE
LAV LAVATORY
LBS/HR POUNDS PER HOUR
LNG LIQUID NATURAL GAS
LOX LIQUID OXYGEN
LW LOW WATER
M METER
MA MEDICAL AIR
MAV MANUAL AIR VENT
MBH 1000 BTUH
MED MEDICAL
MER MECHANICAL EQUIPMENT ROOM
MH MANHOLE
MSB MOP SERVICE BASIN
MV MEDICAL VACUUM
KW KILOWATT
KWHR KILOWATT-HOUR
ICW INDUSTRIAL COLD WATER
INV INVERT
IPC INTERNATIONAL PLUMBING CODE
IRW IRRIGATION WATER
IW INDIRECT WASTE
IWH INSTANTANEOUS WATER HEATER
IWR INDUSTRIAL WATER RETURN
IWS INDUSTRIAL WATER SUPPLY
H&CW HOT AND COLD WATER
HB HOSEBIBB
HD HUB DRAIN
HEX HEAT EXCHANGER
HP HORSEPOWER
HS HAND SINK
HST HOT WATER STORAGE TANK
(DOMESTIC)
HW HOTWATER
HWB HOT WATER BOILER
HWCP HOT WATER CIRCULATING PUMP
HWP HOT WATER PUMP
HYD HYDRANT
PA PASCAL
PD PRESSURE DROP OR DIFFERENCE
PG PRESSURE GAGE
PP PLUMBING PUMP
PPM PARTS PER MILLION
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH ABSOLUTE
PSIG POUNDS PER SQUARE INCH GAUGE
PTRV PRESSURE TEMPERATURE RELIEF
VALVE
PW POTABLE WATER
S SINK
SAN SANITARY SEWER
SCFM STANDARD CUBIC FOOT/MINUTE
SCW SOFTENED COLD WATER
SDMH STORM DRAIN MANHOLE
SP SUMP PUMP
SPR SPRINKLER LINE
SQFT SQUARE FEET
SS STAINLESS STEEL
ST STORAGE TANK
ST STORM
ST OVFL STORM OVERFLOW
STER
TCV TEMPERATURE CONTROL VALVE
TD TEMPERATURE DIFFERENCE
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TEMP TEMPERATURE
TMV THERMOSTATIC MIXING VALVE
TP TRAP PRIMER
TSTAT THERMOSTAT
TWR TEMPERED WATER RETURN
TWS TEMPERED WATER SUPPLY
TYP TYPICAL
V VENT
VAC VACUUM
VB VACUUM BREAKER
VCO VACUUM CLEANER OUTLET
VP VACUUM PUMP
VS VENT STACK
VTR VENT THROUGH ROOF
W WASTE
WC WATER CLOSET
WCO WALL CLEANOUT
WG WATER GAGE
WH WALL HYDRANT
WH WATER HEATER
WHA WATER HAMMER ARRESTER
WL WATER LINE
WM WATER METER
WPD WATER PRESSURE DROP
WS WASTE STACK
WSFU WATER SUPPLY FIXTURE UNITS
P-X
DETAIL NUMBER
DRAWING NUMBER WHERE SHOWN
SECTION LETTER
TYPICAL UNIT NO.
PUMP NUMBER
EQUIPMENT ABBREVIATION (PUMP)
DRAWING NUMBER WHERE DRAWN
X
DOMESTIC HOW WATER RETURN,
STORM WATER, BELOW GRADE
STORM WATER
SANITARY SEWER, BELOW GRADE
DRAIND
SAN
ST
ANCHOR
REDUCER OR INCREASER
DIRECTION OF FLOW
SIDE CONNECTION
ECCENTRIC REDUCER
DIRECTION OF PIPE PITCH (DOWN)
UNION
PIPE UP
PIPE DOWN
CO CLEAN OUT
MODULATING CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
AUTOMATIC FLOW CONTROL VALVE
PRESSURE RELIEF VALVE
# WSFU FOR SUPPLY PIPE NOTED
x
DFU
DFU FOR DRAINAGE PIPE NOTED
(x EQUALS THE NUMBER OF DFU)
HOT WATER RETURN
POINT OF CONNECTION
POINT OF DEMOLITION
TWO POSITION CONTROL VALVE (BALL VALVE)
SOLENOID OPERATED
M
FLOW CONTROL BALANCE VALVE ASSEMBLY
1. PLUMBING CONTRACTOR SHALL CONFIRM ELEVATIONS, LOCATIONS, SIZES AND CONNECTION POINTS OF EXISTING PIPING AND EQUIPMENT AT JOB
SITE.
2. PLUMBING CONTRACTOR SHALL COORDINATE THE INSTALLATION OF HIS WORK WITH EXISTING CONDITIONS AND WITH THE WORK OF OTHER
TRADES.
3. PLUMBING CONTRACTOR SHALL PROVIDE PIPE SLEEVES AND FIRE STOPPING FOR ALL UTILITY PIPING THROUGH FIRE RATED WALLS.
4. PLUMBING CONTRACTOR SHALL COORDINATE AND FIELD VERIFY ALL THE WORK AND AND MANUFACTURER'S REPRESENTATIVE. THE ENTIRE INSTALLATION SHALL COMPLY WITH ALL APPLICABLE LOCAL CODES PERTAINING TO SUCH SYSTEMS. CONTRACTOR SHALL CONFIRM ALL CODE
REQUIREMENTS BEFORE BEGINNING WORK..
5. PLUMBING CONTRACTOR SHALL PROVIDE PLUMBING FIXTURES AS SCHEDULED OR APPROVED EQUAL.
6. COORDINATE ROUTING OF PIPING ABOVE CEILING IN ALL LOCATIONS WITH THE INSTALLATION OF DUCTWORK, CONDUIT, CABLE TRAY, EXISTING
PIPING, AND STRUCTURE.
7. SEE DETAIL 3 ON SHEET P501 FOR PIPING SUPPORT DETAIL.
8. SEE DETAIL 4 ON SHEET P501 FOR PIPE THROUGH INTERIOR WALL DETAIL.
DHWR/HWR
DHW/HW
DCW/CW
TAG
FD-1
HD-1
PLUMBING FIXTURE CONNECTION SCHEDULE
HUB DRAIN
WASTEDESCRIPTION
SERVICE SIZE (INCHES)
VENT CW HW
3FLOOR DRAIN
CW HW TOTAL DFU
WSFU
NOTES:
1. DFU'S AND WSFU'S PER VA PLUMBING DESIGN MANUAL, NOV 2014.
2. SEE PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION.
3. SEE DETAIL 2 ON SHEET P501 FOR FLOOR DRAIN DETAIL.
4. PROVIDE JAY R. SMITH MODEL 5903 NON-FREEZE SANITARY ROOF HYDRANRS
1-1/2
1-1/2
V
V
CA
REVERSE OSMOSIS RETURNROR
COMPRESSED AIR
REVERSE OSMOSIS RETURNROS
ETR EXISTING TO REMAIN
WASH AUTOMATIC WASHER
STERILIZER
1. QUARTER TURN SHUT-OFF VALVES, POPPET CHECK VALVES, BROURE STRAINER. WATTS
SERIES 919 OR EQUIVALENT
2. PROVIDE AIR GAP FITTING, ROUTE DRAIN TO NEW FLOOR DRAIN BELOW UNIT AT
EQUIPMENT PAD.
3. CONTRACTOR TO REGISTER WITH STATE OF WISCONSIN. SERVES HVAC HYDRONIC MAKE
UP WATER.
NOTES:
TAG
BACKFLOW PREVENTERS (BFP-)
REMARKS
B32-BFP-1
FLOW
SERVES SIZE RATE
PRESSURE
LOSS
RPZ REDUCED PRESSURE ZONE
BACKFLOW PREVENTER
2 GPM1" 16 PSIHVAC (1) (2) (3)
RD-1 ROOF DRAIN 4 - - - - -- -
OVERFLOW DRAINOFD-1 4
HB-1
HB-2
HOSE BIBB EXTERIOR
HOSE BIBB INTERIOR 3/4"
3/4" 1
NOTES
HB-3 FROST PROOF HOSE BIBB 3/4" 1 4 4
TAG LOCATION
SUMP PUMP SCHEDULE (SP-)
PHASE
VOLTS/
(HP)
SIZE
NOTES
WATER
FLOW
(GPM) (FT)
HEAD DISCH.
(IN.)
MOTOR
(RPM)
SPEED
MOTOR
SP-1 B032 EXIST
MECH ROOM
2 3450 1, 2
SP-2
1-1/2 208/1/60
21-1/2
50 12
B032 EXIST
MECH ROOM
50 12 208/1/60 3450
SP-3
ELEVATOR
PIT 50 12 1-1/2 208/1/60 2 3450 3
SP-4
TELECOM CONCRETE
VAULT-B32 50 12 1-1/2 208/1/60 2 3450
1, 2
NOTE:
1. SERVE CLEAR WATER DRAINAGE, DRAIN TILES SYSTEM & HVAC UNIT CONCRETE.
2. DUPLEX SYSTEM.
3. SIMPLEX SYSTEM.
SP-5
NEW ELECTRICAL
VAULT
50 12 1-1/2 208/1/60 2 3450 3
PART
NUMBER LOCATION
SUMP PUMP BASIN COVER SCHEDULE (SP-)
BOLT CIRCLE THICKNESSSTYLE
BASIN
INSIDE
DIM.
OUTSIDE
DIM
HATCH
DOOR
WIDTH
HATCH
DOOR
LENGTH
CLEAR
ACCESS
WIDTH
CLEAR
ACCESS
LENGTH
DISTANCE
C48HSF
NEW ELECTRICAL
VAULT 48ØROUND 54Ø 51.0 .500 26 38 24 36 21
SP-6
SEE CIVIL SHEET C102
FOR EXACT LOCATION
50 12 1-1/2 2 3450 3
SP-7
SEE CIVIL SHEET C102
FOR EXACT LOCATION
50 12 1-1/2 2 3450 3
208/1/60
208/1/60
HP KW V ∅
NOTE
NOTES:
1. DISCONNECT LOCATION NEAR PUMP.
EQUIPMENT
ELECTRICAL
DATA
TYPE
STARTER
LOCATION
FURN. BY ACCESSORIES
DISCONNECT AT UNIT
FURN. BY
LOCATIONTAG
B32-SP-1 2 -208- -1 X-X XX --- -- --- 1- - X
B32-SP-2 -208- -1 -X --- -- --- 1- - X
MECH RM
MECH RM
NEAR UNIT
NEAR UNIT X XX
E Q
U
IP
M
A N
U F
A C
T U
R E
R
M A
N U
A L
M A
G N
E T
IC
C O
M B
IN
A
T
IO
N
V F
D
P L U
M B
C
O N
T R
A C
T O
R
E L E
C
C O
N T
R A
C T
O R
P
IL
O T
L
IG
H T
P U
S H
B U
T T
O N
H A
N D
-O F
F -A
U T
O
N O
T R
E Q
U
IR
E D
W E
A T
H E
R P
R O
O F
F U
S E
D
R E
D U
C E
D V
O L T
A G
E
T W
O S
P E
E D
E Q
U
IP
M
A N
U F
A C
T U
R E
R
E M
E R
G E
N C
Y P
O W
E R
E L E
C
C O
N T
R A
C T
O R
P L U
M B
C
O N
T R
A C
T O
R
PLUMBING MOTOR STARTER SCHEDULE
B32-SP-3 ELEVATOR
PIT
B32-SP-4 EXISTING TELECOM
VAULT-B32
-208 -1 X-X XX --- -- --- 1- - X
-208 -1 -X --- -- --- 1- - X
NEAR UNIT
IN B32 X XX
-2
B32-SP-5 -X --- -- ---XIN B32 X XX--208 -1 - --2
NEW ELECTRICAL
VAULT-B32
2. SEE C102 DRAWINGS
B32-SP-6 -X --- -- ---XIN B32 X XX--208 -1 - --2
NEW ELECTRICAL
VAULT-B32
B32-SP-7 -X --- -- ---XIN B32 X XX--208 -1 - --2
NEW ELECTRICAL
VAULT-B32
B32-SP-8 -X --- -- ---XIN B32 X XX--208 -1 - --2
NEW ELECTRICAL
VAULT-B32
1, 2
1, 2
1, 2
3770 S. PENNSYLVANIA AVENUE, UNIT 8
ST. FRANCIS, WISCONSIN 53235
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked By
Building Number
Project Number
Drawing Number
Drawn By
PROJECT LEADER:
Department of Veterans Affairs
CONSULTANTS:
o n e e ig h th in ch o n e f o o t th re e in ch e s o n e f o o t o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t o n e q u a rt e r in ch o n e f o o t
VA FORM 08-6231, OCT 1978
500 E VETERANS ST
TOMAH, WI 54660
MEDICAL CENTER
VETERANS AFFAIRS
FULLY SPRINKLERED
500 E VETERANS ST
TOMAH, WI 54660
MEDICAL CENTER
VETERANS AFFAIRS
FULLY SPRINKLERED
Office of Facilities
Management
B
A
C
D
E
F
97 8654321
F
E
D
C
B
A
1 2 3 4 5 6 87 9
FULLY SPRINKLEREDFULLY SPRINKLERED
EHRM INFRASTRUCTURE
UPGRADES TIER 2
VA MEDICAL CENTER TOMAH, WI
FEB. 4, 2022 JMD ML
P001P001
FINAL BID DOCUMENTS
676-21-701PLUMBING
LEGEND, ABBREVIATIONS, AND
SCHEDULES
No. Description Date
Revised Per Pre-Bid 2/18/2020
ADG-W-23
Highlight
SUMP PUMP SCHEDULE (SP-
ADG-W-23
Highlight
PLUMBING MOTOR STARTER SCHEDULE
ADG-W-23
Highlight
B32-SP-4 EXISTING TELECOM
ADG-W-23
Highlight
TELECOM
File details come from the government source that posted it. Updated .