Attachment R- 2W IR CATH EP_IR Lab_Site Specific.pdf
PDF 4 MB Posted
- Solicitation number
- 36C26323R0002
About this file
This document includes reference drawings and specifications for a remodel project at a Veterans Affairs medical center in Iowa City, Iowa. The project involves remodeling space for interventional radiology, cardiac catheterization, and electrophysiology services. Key requirements and specifications include storage space for items during installation, completed lead shielding, climate control, verified delivery paths for large equipment, finished casework, primed and painted walls and installed flooring, completed and functional room lighting, obtained IP addresses for remote service, verified floor thickness and anchoring, installed conduits and cable runs ensuring maximum length limits are not exceeded, installed x-ray warning lights and wiring, installed electrical wiring and pigtails, located cable inlets per plans, installed and functional emergency power-off switches and uninterruptible power supply, installed ancillary equipment, installed breakers, and ensuring all rooms are clean and dust-free prior to equipment installation.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA IOWA CITY 584
2104151
A-101ATTENTION:
R E
F E
R E
N C
E
D
O C
U M
E N
T
N
O T
F
R
C
N
S T
R U
C T
I O
N
WITH TILTING TABLE
PROJECT MILESTONES TO BE COMPLETED BEFORE EQUIPMENT DELIVERY
Storage area available for storing items during installation
Lead shielding (walls, doors, windows) complete
Climate control functioning 24 hours a day, 7 days a week
Delivery path verified for largest piece, including rails
Casework complete in control room
All walls primed and painted. Flooring installed
Room lighting complete and functional
Network drops active and IP addresses obtained for Siemens Remote Services (SRS)
Nothing hanging below ceiling in area shaded on drawing
Floor thickness and anchoring spec's verified. If req'd, alt solutions per engineer of record in place
All conduits, troughs, in-floor pull boxes and/or core drills avoid conflict with floor plate anchors
Unistrut installed to correct height, location, and levelness (check minimum ceiling height)
Cable runs checked to ensure maximum lengths not exceeded
X-Ray warning light and wiring installed
Contractor supplied electrical wiring / pigtails installed
Cable inlets located per plans
EPO's installed and functional
UPS started and functional
Ancillary equipment (OEM items, booms, etc) installed
Breakers installed and facility power available
All rooms containing Siemens equipment are clean and dust-free
REFERENCE SHEET
A-101
A-101
A-101
A-101
A-101
A-101
A-101
A-102
A-102
S-101
S-101
S-102
E-101
E-101
E-102
E-102
E-102
E-102
E-102
E-501
A-101
A-102ATTENTION:
R E
F E
R E
N C
E
D
O C
U M
E N
T
N
N
S T
R U
C T
I
N
S-101ATTENTION:
R E
F E
R E
N C
E
D
O C
U M
E N
T
N
N
S T
R U
C T
I
S-102ATTENTION:
R E
F E
R E
N C
E
D
O C
U M
E N
T
N
N
S T
R U
C T
I
E-101ATTENTION:
R E
F E
R E
N C
E
D
O C
U M
E N
T
N
N
S T
R U
C T
I
E-102ATTENTION:
R E
F E
R E
N C
E
D
O C
U M
E N
T
N
N
S T
R U
C T
I
E-501ATTENTION:
R E
F E
R E
N C
E
D
O C
U M
E N
T
N
N
S T
R U
C T
I
M-501ATTENTION:
R E
F E
R E
N C
E
D
O C
U M
E N
T
N
N
S T
R U
C T
I O
N
ATTENTION:
R E
F E
R E
N C
E
D
O C
U M
E N
T
N
N
S T
R U
C T
I
File details come from the government source that posted it. Updated .