This document is a disclaimer for a power system study prepared using industry-standard engineering practices and Easy Power's software. The disclaimer outlines the methodological approach to the electrical system analysis, which includes data input, conversion of physical characteristics to impedance values, short circuit calculations, protective device coordination, and arc flash evaluation.
The document emphasizes that the report is intended for qualified personnel familiar with the facility and the engineering principles used in its creation. It warns that changes or modifications to the studied electrical system - such as utility system alterations, failure to maintain equipment within manufacturer specifications, or adjustments to protective device settings - could invalidate the reported findings. The preparer also explicitly assumes no responsibility for inaccuracies in data provided by others and recommends a thorough review by personnel fully familiar with the facility to ensure accurate system representation.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Disclaimer
The following report was prepared based on data gathered or provided by others, published information, through onsite discovery, equipment nameplate data, manufacturer ratings, or other means.
The power system study was prepared using industry accepted standards and practices. Easy Power’s software was used for power systems analysis encompassing data input and conversion of physical characteristic to impedance values, short circuit calculations, protective device coordination, and arc flash evaluation.
Changes or modifications to the studied electrical system either in configuration or equipment may make reported findings invalidate. Such changes can include changes in the utility system, failure to maintain equipment within manufacturer specifications, changes or adjustments in protective device settings, etc.
This report is intended to be used and interpreted by qualified personnel that are familiar with the facility and the engineering principles used in creating this report. It is recommended this report be reviewed by personnel that are fully familiar with this facility to insure the system is accurately represented. Preparer of report assumes no responsibility for inaccuracies for data provided by others.