NOVA VOLUME 2-Low Voltage_2013_0930.pdf
PDF 5 MB Posted
- Solicitation number
- 36C25625R0084
About this file
The attached low voltage telecommunications documents are detailed construction drawings for Building 04 and Building 05 of the Southeast Louisiana Veterans Healthcare System replacement medical center project in New Orleans, Louisiana. The drawings comprehensively specify low voltage infrastructure requirements, including:
Telecommunications systems design details covering multiple building floors, including conduit pathways, cable routing, outlet configurations, grounding systems, fiber optic backbone cabling, voice and data network infrastructure, overhead paging systems, and distributed antenna systems. The drawings provide technical specifications for telecommunications rooms, equipment rack layouts, cable management, patch panel configurations, and standardized outlet types with specific port designations for voice, data, wireless access points, wall phones, and floor boxes. Drawings are dated June 30, 2011, and include multiple addenda through November 30, 2011, indicating a detailed design development process for the Veterans Affairs medical center construction project.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PR
POTS
POI
INTEGRATED SERVICES DIGITAL NETWORK
INTERNATIONAL STANDARDS ORGANIZATION
INSIDE WIRING (CABLE)
KILOHERTZ
POINT OF INTERFACE
PAIR
PLAIN OLD TELEPHONE SERVICE
KHz
IW
ISO
ISDN
DC
DB
DAF
D/A DIGITAL TO ANALOG CONVERSION
DEDICATED ACCESS FACILITY
DECIBEL
A/D
AC
8P8C 8-POSITION, 8-CONDUCTOR
ALTERNATING CURRENT
ANALOG TO DIGITAL CONVERSION
TB
SYS
SWB
SW
STP
STA
SPG
SPD
SPC
SP
SNA
SMPS
SI
PVC
SE
SL
SER
KEY TELEPHONE SYSTEM
LOCAL AREA NETWORK
LIGHT AMPLIFICATION BY STIMULATED EMISSION OF RADIATION
LOCAL ACCESS TRANSPORT AREA.
LINE BUILDOUT
LOCAL EXCHANGE CARRIER
LIGHT EMITTING DIODE
LOW CAPACITANCE
MANUFACTURING AUTOMATION/PROTOCOL
MAXIMUM
MAIN CROSS-CONNECT
MAIN DISTRIBUTION FRAME
MOTOR/GENERATOR SET
MAINTENANCE HOLE
MICROMETER
MINIMUM
MISCELLANEOUS
POLYVINYL CHLORIDE
SERVICE ENTRANCE
SATELLITE EQUIPMENT ROOM
SYSTEM INTERNATIONAL
SLEEVE
SERVICE PROVIDER
STORED PROGRAM CONTROL
SURGE PROTECTION DEVICE
SINGLE-POINT GROUND
STATION
SHIELDED TWISTED PAIR
STATION WIRE
SWITCHBOARD
SYSTEM
TERMINAL BLOCK
SWITCHED MODE POWER SUPPLY
SYSTEMS NETWORK ARCHITECTURE
TSB
TPPMD
TPDDI
TO
TMGB
TM
TIA
THD
TGB
TERM
TELCO
TEL
TEBC
TDM
TC
TBC
TR
MINIMUM POINT OF PRESENCE
MAIN TELEPHONE TERMINAL
NEWTON
NATIONAL ELECTRIC CODE
NATIONAL ELECTRIC SAFETY CODE
NETWORK INTERFACE
NOT IN CONTRACT
NETWORK INTERFACE DEVICE
NETWORK INTERFACE UNIT
NATIONALLY RECOGNIZED TESTING LABORATORY
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OPTICAL FIBER NON-CONDUCTIVE PLENUM
OPTICAL FIBER NON-CONDUCTIVE RISER
OVERCURRENT PROTECTION DEVICE
OUTSIDE PLANT ENGINEER
TIME DIVISION MULTIPLEXING
TELEPHONE
TELEPHONE COMPANY
TERMINAL
THIRD HARMONIC DISTORTION
TELECOMMUNICATIONS ROOM
TELECOMMUNICATIONS BONDING CONDUCTOR
TELECOMMUNICATIONS CLOSET
TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTOR
TELECOMMUNICATIONS GROUNDING BUSBAR
TELECOMMUNICATIONS INDUSTRY ASSOCIATION
TRANSFORMER MAINTENANCE HOLE
TELECOMMUNICATIONS MAIN GROUNDING BUSBAR
TELECOMMUNICATIONS OUTLET
TWISTED PAIR DISTRIBUTED DATA INTERFACE
TWISTED PAIR PHYSICAL MEDIA DEPENDENT
TELECOMMUNICATIONS SYSTEM BULLETIN
TBBC
MODULATOR/DEMODULATOR
TELECOMMUNICATIONS BACKBONE BONDING CONDUCTOR
MIN
MAX
MISC
MICRON
MH
M/G
MDF
MC
MAP
LOCAP
LED
LEC
LBO
LATA
LASER
LAN
KTS
ELEC
DWG
EC
EMT
EMR
EMI
EMC
EIA
EF
DW
DTE
DGM
DEMARC
DD
DCO
DCE
EBC
DATA CIRCUIT-TERMINATION EQUIPMENT
DIGITAL CENTRAL OFFICE
DISTRIBUTION DESIGNER
DEMARCATION POINT
DATA GRADE MEDIUM
DATA TERMINAL EQUIPMENT
DISTRIBUTION WIRE
DRAWING(S)
EQUIPMENT BONDING CONDUCTOR
ELECTRICAL CONTRACTOR
ENTRANCE FACILITY
ELECTRONICS INDUSTRY ASSOCIATION
ELECTRICAL
ELECTROMAGNETIC COMPATIBILITY
ELECTROMAGNETIC INTERFERENCE
ELECTROMAGNETIC RADIATION
ELECTRIC METALLIC TUBING
BEF
BDF
BD
BBISDN
B
AWG
ATM
ASCII
ARMM
ANSI
AM
AIA
AFF
AER
ADO
ADA
BC
AMERICANS WITH DISABILITIES ACT
AUXILIARY DISCONNECT OUTLET
AERIAL
ABOVE FINISHED FLOOR
AMERICAN INSTITUTE OF ARCHITECTS
AMPLITUDE MODULATION
AMERICAN NATIONAL STANDARDS INSTITUTE
ASYNCHRONOUS TRANSFER MODE
AMERICAN WIRE GAUGE
BURIED
BONDING CONDUCTOR
BROAD BAND INTEGRATED SERVICES DIGITAL NETWORK
BUILDING DISTRIBUTOR
BUILDING DISTRIBUTION FRAME
BUILDING ENTRANCE FACILITY
PIC RISER, EXPANDED POLYETHYLENE PVC, 24 AWG, ALVYN
AMERICAN STANDARD CODE FOR INFORMATION INTERCHANGE
OC
OD
FDDI
OPE
OPD
NTS
NRTL
NIU
NID
NIC
NI
NESC
NEC
N
MTT
MPOP
GND
GHz
GEC
GA
FTP
FREQ
FOTP
FDR
FDM
FD
FCC
EXT
EXCH
ESS
E/W
OFNP
OFNR
FO
EQUIPPED WITH
ELECTRONIC SWITCHING SYSTEM
EXCHANGE
EXTENSION
FEDERAL COMMUNICATIONS COMMISSION
FLOOR DISTRIBUTION
FIBER DISTRIBUTED DATA INTERFACE
FREQUENCY DIVISION MULTIPLEXING
FEEDER
FIBER OPTIC
FIBER OPTIC TRANSMISSION SYSTEM
FREQUENCY
FOIL TWISTED PAIR
GAUGE
GROUNDING ELECTRIC CONDUCTOR
GIGAHERTZ
GROUND
CC
CLO
CFC
CIRC
CDO
CDF
CDDI
CD
CCITT
CBC
CATV
CA
BTU
BRISDN
BICSI
BIC
CER
BUILDING INDUSTRY CONSULTANT
BUILDING INDUSTRY CONSULTING SERVICES
BASIC RATE INTEGRATED SERVICES DIGITAL NETWORK
BRITISH THERMAL UNIT
CABLE
CABLE TELEVISION
COUPLED BONDING CONDUCTOR
COMMUNICATIONS CONTRACTOR
CONDUIT
COPPER DISTRIBUTED DATA INTERFACE
COPPER DISTRIBUTION FRAME
COMMUNITY DIAL OFFICE
COMPUTER EQUIPMENT ROOM
CIRCUIT
COMMUNICATIONS FLAT CABLE
CLOSET
THE INTERNATIONAL TELEGRAPH AND TELEPHONE CONSULTATIVE COMMITTEE
MODEM
ETV
BER BIT ERROR RATE
EDUCATIONAL TELEVISION
PTSS
ACO ANALOG CENTRAL OFFICE
DIRECTED CURRENT PASSIVE TRANSMISSION SUBSYSTEM
UTP
UPS
UL
UG
TYP
TVSS
TTY
TTB
OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
OUTSIDE PLANT
PULSE AMPLITUDE MODULATE
PULL BOX
PRIVATE BRANCH EXCHANGE
PULSE CODE MODULATION
POLYETHYLENE INSULATED CONDUCTOR
PRIVATE LINES
PLANT
PHASE MODULATION
TELEPHONE TERMINAL BOARD
TEXT TELEPHONES
TYPICAL
UNDERGROUND
UNSHIELDED TWISTED PAIR
TRANSCEND VOLTAGE SURGE SUPPRESSOR
UNDERWRITERS LABORATORIES
UNINTERRUPTIBLE POWER SUPPLY
OSP
OSHA
IEEE
IDC
ICEA
IC
Hz
HVAC
HH
HF
PM
PLT
PL
PIC
PCM
PBX
PAM
PB
IDF
HIGH FREQUENCY
HANDHOLE
HEATING, VENTILATION AND AIR CONDITIONING
INTERMEDIATE CROSS CONNECTED
INSULATED CABLE ENGINEERS ASSOCIATION
INSULATION DISPLACEMENT CONNECTION
INTERMEDIATE DISTRIBUTION FRAME
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS
HERTZ
CSMA/CD
CSMA/CA
CSA
CPU
CPE
CPC
COT
COE
CODEC CODER/DECODER
CENTRAL OFFICE EQUIPMENT
CENTRAL OFFICE TERMINAL
CUSTOMER PREMISES COMMUNICATIONS
CUSTOMER PREMISES EQUIPMENT
CENTRAL PROCESSING UNIT
CANADIAN STANDARDS ASSOCIATION
CARRIER SENSE MULTIPLE ACCESS/COLLISION AVOIDANCE
CARRIER SENSE MULTIPLE ACCESS/COLLISION DETECTION
HC
TT
CO CENTRAL OFFICE
HORIZONTAL CROSS-CONNECT
TELEPHONE TERMINAL
GENERAL TELECOMMUNICATIONS ABBREVIATIONS
1.
2.
3.
4.
5.
6.
7.
8.
10.
11.
9.
12.
13.
14.
15.
GENERAL PATHWAY REQUIREMENTS
16.
17.
19.
20.
18.
INSTALL CONDUIT RUNS IN THE MOST DIRECT ROUTE POSSIBLE WITH NO MORE THAN TWO 90 DEGREE BENDS
BETWEEN PULL POINTS OR PULL BOXES.
90 DEGREE CONDULETS OR "LB" TYPE FITTINGS SHALL NOT BE USED FOR TELECOMMUNICATIONS CABLING
INSTALLATIONS.
CONTINUOUS CONDUIT SECTIONS SHALL NOT BE GREATER THAN 100 LINEAR FEET IN LENGTH WITHOUT AN
ADEQUATELY SIZED PULL BOX.
CONDUITS SHALL BE BONDED TO GROUND ON ONE OR BOTH ENDS IN ACCORDANCE WITH NATIONAL AND LOCAL
REQUIREMENTS.
TELECOMMUNICATIONS CONDUITS SHALL BE INSTALLED TO WITHSTAND THE ENVIRONMENT IN WHICH THEY WILL BE
EXPOSED AND IN ACCORDANCE WITH ANSI/NFPA-70; THE NATIONAL ELECTRICAL CODE.
THE TOTAL DISTANCE OF CONDUIT RUNS FOR TELECOMMUNICATIONS HORIZONTAL CABLE USE SHALL NOT EXCEED
150 FEET.
DO NOT INSTALL CONDUITS OVER OR ADJACENT TO BOILERS, INCINERATORS, HOT WATER OR STEAM LINES.
THE MINIMUM BEND RADIUS OF ANY PORTION OF THE CONDUIT PATHWAY SHALL BE SIX (6) TIMES THE INTERNAL
DIAMETER OF THE CONDUIT FOR ALL CONDUITS 2-INCHES IN DIAMETER OR LESS.
THE MINIMUM BEND RADIUS OF ANY PORTION OF THE CONDUIT PATHWAY SHALL BE TEN (10) TIMES THE INTERNAL
DIAMETER OF THE CONDUIT FOR ALL CONDUIT WITH AN INTERNAL DIAMETER GREATER THAN 2-INCHES.
WHERE A CONDUIT RUN REQUIRES A REVERSE BEND (BETWEEN 100 DEGREES AND 180 DEGREES) A PULL BOX
SHALL BE INSTALLED AT EACH BEND HAVING SUCH ANGLE, WITHIN 10 FEET OF THE BEND.
IF A CONDUIT RUN REQUIRES A THIRD 90 DEGREE BEND BETWEEN PULL POINTS OR PULL BOX, THE OVERALL
DESIGN CAPACITY OF THE CONDUIT SYSTEM SHALL HAVE A DERATED TOTAL CAPACITY OF 15 PERCENT.
ALL CONDUIT ENDS SHALL BE REAMED AND FITTED WITH THREADED INSULATING BUSHING TO ELIMINATE SHARP
EDGES THAT CAN DAMAGE CABLES DURING INSTALLATION.
CONDUITS THAT PROTRUDE THROUGH WALLS AND FLOORS SHALL BE EXTENDED BEYOND THE SURFACE PENETRATION. TO
WITHIN 12 INCHES OF CABLE RUNWAY SYSTEM. ALL CABLING SHALL BE IN CONDUITS.
ALL CONDUITS SHALL BE EQUIPPED WITH NYLON FISHTAPE OR PULL CORDS WITH A MINIMUM TEST RATING OF 200
LBS.
INSTALL PULL BOXES IN ACCESSIBLE LOCATIONS. DIRECT ACCESS TO PULL BOXES IS REQUIRED. PROVIDE
LABELED, HINGED ACCESS PANEL DOOR. PULL BOXES SHALL BE LISTED FOR THE PURPOSE.
THE MINIMUM LENGTH OF PULL BOX SHALL BE 12 TIMES THE DIAMETER OF THE LARGEST CONDUIT. PULL BOXES
SHALL NOT BE USED IN SUBSTITUTION OF A 90° BEND.
REFER TO "TI" SERIES AV DRAWINGS FOR MOUNTING ELEVATIONS .
REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION OF ALL CONDUIT, RUNWAY, AND TRAY.
COORDINATE EXACT LOCATIONS OF ALL FLOOR BOXES WITH ARCHITECT PRIOR TO INSTALLATION.
ALL OUTLET LOCATIONS AND DIMENSIONS ASSOCIATED WITH ARE APPROXIMATE. COORDINATE EXACT MOUNTING
LOCATION AND HEIGHT WITH ARCHITECTURAL DRAWINGS PRIOR TO INSTALLATION.
STANDARD TEL/DATA OUTLET. INSTALL (1) ONE 6-PORT FACEPLATE ONTO BACK BOX OR OTHER APPROVED RACEWAY. PORTS SHALL BE DESIGNATED: V1, V2, D2, D2, SPARE 1, AND SPARE 2 (FUTURE USE). INSTALL (1) ONE RJ45 JACK INSERT INTO EACH PORT, COLOR AND PORT LOCATION AS INDICATED ON 9TN002 OUTLET DETAIL. INSTALL 1 UTP CABLE FOR EACH RJ45 JACK INSERT INSTALLED, IN A COLOR TO MATCH THE RJ45 JACK INSERT TO WHICH IT IS TERMINATED, AS INDICATED ON 9TN002 OUTLET DETAIL, TERMINATING ALL 8 CONDUCTORS. BLANK INSERTS SHALL BE
INSTALLED IN ANY UNUSED PORTS IN A COLOR TO MATCH THE FACEPLATE.
COMMUNICATIONS LEGEND
WIRELESS ACCESS PORT OUTLET. INSTALL (1) ONE 3-PORT FACEPLATE ONTO BACK BOX OR OTHER APPROVED RACEWAY. PORTS SHALL BE DESIGNATED: D1, D2, AND D3. INSTALL (1) ONE RJ45 JACK INSERT INTO 3 PORTS. COLOR AND PORT LOCATION AS INDICATED ON 9TN002 OUTLET DETAIL. INSTALL 1 UTP CABLE FOR EACH RJ45 JACK INSERT INSTALLED, IN A COLOR TO MATCH THE RJ45 JACK INSERT TO WHICH IT IS
TERMINATED, AS INDICATED ON 9TN002 OUTLET DETAIL, TERMINATING ALL 8 CONDUCTORS.
VOICE ONLY WALL PHONE OUTLET. INSTALL (1) ONE STAINLESS STEEL 1-PORT FACEPLATE ONTO BACK BOX OR OTHER APPROVED RACEWAY. PORT SHALL BE DESIGNATED: V1. INSTALL (1) ONE RJ45 JACK INSERT INTO THE PORT, COLOR AS INDICATED ON 9TN002 OUTLET DETAIL. INSTALL 1 UTP CABLE INTO THE RJ45 JACK INSERT INSTALLED, IN A COLOR TO MATCH THE RJ45 JACK INSERT TO WHICH IT IS TERMINATED, AS INDICATED ON 9TN002
OUTLET DETAIL, TERMINATING ALL 8 CONDUCTORS.
FLOOR BOX OUTLET. INSTALL (1) ONE 4-PORT FACEPLATE ONTO DESIGNATED FLOOR BOX. PORTS SHALL BE DESIGNATED: V1, V2, D1, AND D2.
INSTALL (1) ONE RJ45 JACK INSERT INTO EACH PORT, COLOR AND PORT LOCATION AS INDICATED ON 9TN002 OUTLET DETAIL. INSTALL 1 UTP CABLE FOR EACH RJ45 JACK INSERT INSTALLED, INA COLOR TO MATCH THE RJ45 JACK INSERT TO WHICH IT IS TERMINATED, AS INDICATED ON 9TN002 OUTLET DETAIL, TERMINATING ALL 8 CONDUCTORS. BLANK INSERTS SHALL BE INSTALLED IN ANY UNUSED PORTS IN A COLOR TO MATCH THE
FACEPLATE.
WL
W
4" CEILING MOUNTED OVERHEAD PAGING SPEAKER. TO LOCATE WITHIN 6" TECHNOLOGY STRIPS IN CEILINGS
WALL MOUNTED OVERHEAD PAGING SPEAKER MOUNTED AT 7'-6" AFF UNLESS OTHERWISE NOTEDS
FIBER OPTICS LINE = FOFO
TELEPHONE LINE = TT
INTERCOMMUNICATIONS LINE = I ; MINIMUM 3/4" CONDUITI
SOUND LINE = S; #16AWG, 2-CONDUCTOR, STRANDED BARE COPPER,
WITH SHIELDING AND OVERALL JACKET, PLENUM RATED
S
RADIO CONDUIT RUN, MINIMUM 1" CONDUITR
DISTRIBUTED ANTENNA SYSTEM OMNI DIRECTIONAL ANTENNA - CEILING MOUNTED, SHOWN FOR
INFORMATION ONLY. DAS SHALL BE PROVIDED PER SPECIFICATION 27.53.19A
A
DISTRIBUTED ANTENNA SYSTEM OMNI DIRECTIONAL ANTENNA - WALL MOUNTED, SHOW FOR
INFORMATION ONLY. DAS SHALL BE PROVIDED PER SPECIFICATION 27.53.19
ELEVATOR COMMUNICATIONS CABLE: PROVIDE (1) CAT CABLE COILED WITH 30 FEET OF SLACK FOR TERMINATION INTO THE ELEVATOR
CONTROL PANEL.
E
GENERAL NOTES:
1. THE WIRELESS NETWORK ON THESE PLANS CONSIST OF OUTLETS, STRUCTURED CABLING AND PATHWAYS TO SUPPORT THE VA UNIFIED WIRLESS NETWORK (VAUWN). SITE SURVEY, ACCESS POINTS, CONTROLLERS, RF MANAGMENT, RANGE AP DETECTION AND PREVENTION, AND ASSOCIATED CONTROL
SYSTEMS ARE BEYOND THE SCOPE OF WORK AND ARE PROVIDED BY THE VA.
FIBER REMOTE LINKFRU
LIGHT INTERFACE UNITLIU
STANDARD TEL/DATA OUTLET. INSTALL (1) ONE 4-PORT FACEPLATE ONTO BACK BOX OR OTHER APPROVED RACEWAY. PORTS SHALL BE DESIGNATED: D2 & D2. INSTALL (1) ONE RJ45 JACK INSERT INTO EACH PORT, COLOR AND PORT LOCATION AS INDICATED ON 9TN002 OUTLET DETAIL.
INSTALL 1 UTP CABLE FOR EACH RJ45 JACK INSERT INSTALLED, IN A COLOR TO MATCH THE RJ45 JACK INSERT TO WHICH IT IS TERMINATED, AS INDICATED ON 9TN002 OUTLET DETAIL, TERMINATING ALL 8 CONDUCTORS. BLANK INSERTS SHALL BE INSTALLED IN ANY UNUSED PORTS IN A COLOR
TO MATCH THE FACEPLATE.
X
"X" INDICATES
NUMBER OF PORTS
AP WIRELESS ACCESS POINT
U.O.N. UNLESS OTHERWISE NOTED
TMH TELECOMMUNICATIONS MANHOLE
21. ALL CONDUITS AND CONDUIT FITTINGS, COUPLINGS, SUPPORTS, FASTENERS SHALL BE RGS, GALVENIZED.
2. BASE BID SHALL BE FOR STANDARD, PASSIVE PATCH PANEL SYSTEM FOR COPPER AND FIBER
OPTIC STATION CABLING AND BACKBONE CABLING.
ALTERNATE BID SHALL BE FOR INTELLIGENT PATCH PANEL SYSTEM FOR COPPER AND FIBER
OPTIC STATION CABLING AND BACKBONE CABLING.
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN001
BUILDING 04 LOW VOLTAGE SYMBOLS AND
LEGENDS
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
LABEL
D1 D2
V1 V2
ELECTRICAL DEVICE BOX
6 PORT FLUSH MOUNT
FACEPLATE
OUTLET LABEL
(TYPICAL)
PORT LABEL
(TYPICAL)
PORT 5 BLANK
INSERT
BLUE
BLANK BLANK
BLUE
WHITE WHITE
C A T U T P C A B L E V O
IC
E W H
IT
E
C A T A U T P C A B L E D A T A B L U E
C A T A U T P C A B L E D A T A B L U E
C A T U T P C A B L E V O
IC
E W H
IT
E
PORT 6 BLANK
INSERT
L A B E L
L A B E L
L A B E L
L A B E L
CAT6 CAT6
CAT6ACAT6A
LABEL
D1
D2
ELECTRICAL DEVICE BOX
3 PORT FLUSH MOUNT
FACEPLATE
OUTLET LABEL
(TYPICAL)
BLANK
GREEN
CAT6A
YELLOW
CAT6A
PORT LABEL
(TYPICAL)
C A T A U T P C A B L E D A T A Y E L L O W
C A T A U T P C A B L E D A T A G R E E N
WL
L A B E L
L A B E L6
D3
PORT 3 BLANK
INSERT
M
IN
C L R
FINISH CEILING
SEE RCP
L A B E L
FOG WHITE
MOUNTING SCREW
(TYPICAL)
1 PORT FLUSH MOUNT
FACEPLATE
ELECTRICAL DEVICE BOX
C A T U T P C A B L E V O
IC
E W H
IT
E
W
CAT6
LABEL
D1
ELECTRICAL DEVICE BOX
2 PORT FLUSH MOUNT
FACEPLATE
OUTLET LABEL
(TYPICAL)
PORT LABEL
(TYPICAL)
BLUE BLANK
C A T A U T P C A B L E D A T A B L U E
L A B E L
TV
66" AFF U.O.N.
PORT 2
(BLANK INSERT)
CAT6 BLANK
LABEL
D1 D2
ELECTRICAL DEVICE BOX
4 PORT FLUSH
MOUNT FACEPLATE
OUTLET LABEL
(TYPICAL)
PORT LABEL
(TYPICAL)
BLANK
BLUE BLUE
C A T A U T P C A B L E D A T A B L U E
C A T A U T P C A B L E D A T A B L U E
L A B E L
L A B E L
PORT 3 BLANK
INSERT PORT 4 BLANK
INSERT
BLANK
CAT6A JACK
CAT6A JACK
NUMBER INDICATES QUANTITY OF DATA JACKS
1. CIRCLE AROUND OUTLET INDICATES ABOVE CEILING.
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN002
BUILDING 04 LOW VOLTAGE OUTLET DETAILS
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
12" = 1'-0"
STANDARD OUTLET
12" = 1'-0"
WIRELESS ACCESS POINT OUTLET
12" = 1'-0"
WALL PHONE
12" = 1'-0"
TV OUTLET
12" = 1'-0"
DATA ONLY OUTLET
6 ADDENDUM #6- POST BID 01/27/12
328'-0" MAX. COMBINED LENGTH
295'-0" MAX. LENGTH
1-1/4" EMT CONDUIT WITH APPROVED
BUSHINGS AT END TO NEAREST TR.
NYLON PULL STRING SECURE AT
EACH END (TYPICAL)
BOX SUPPORT OFFSET
CONTRACTOR TO SIZE DEPTH OF
DEVICE COVER PLATE TO INCLUDE
BOX SUPPORT OFFSET, THICKNESS
OF GWB AND FINISH COVERING
(WHERE APPLICABLE)
6" X 6" X 2" METAL
ELECTRICAL BOX
TYPICAL STUD - SEE
ARCHITECTURALS
FINISH SURFACE OR
PARTITION - SEE
ARCHITECTURAL
DEVICE COVER PLATE
MUST BE FLUSH WITH
FINISHED SURFACE OF
PARTITION WALL
6" X 6" DEVICE COVER
PLATE (SINGLE DEVICE)
TYPICAL
COMMUNICATIONS
FACEPLATE
DEVICE BOX - SEE
DOUBLE GANG DEVICE
BOX DETAIL
FINISHED FACE OF
PARTITION - SEE PLAN
(1) 1-1/4" EMT CONDUIT
W/ NYLON PULL STRINGS
TO ACCESSIBLE AREA
INACCESSIBLE CEILING OR
SOFFIT AREA
CEILING - SLAB OR SUPPORT
TERMINATE IN TR.
ACCESSIBLE CEILING
12" MIN.
DEVICES IN PLAN VIEW
TYPICAL BACK BOX
CONDUIT TO ABIVE
ACCESSIBLE CEILING
TYPICAL PARTITION -
SEE PLAN
MAXIMUM TRADE
SIZE OF CONDUIT
SIZE OF PULL BOX
WIDTH LENGTH HEIGHT
FOR EACH ADDITIONAL
CONDUIT - INCREASE
WIDTH
1 INCH
1-1/4 INCHES
1-1/2 INCHES
2 INCHES
2-1/2 INCHES
3 INCHES
3-1/2 INCHES
4 INCHES
4 INCHES
6 INCHES
8 INCHES
8 INCHES
10 INCHES
12 INCHES
12 INCHES
15 INCHES
16 INCHES
20 INCHES
27 INCHES
36 INCHES
42 INCHES
48 INCHES
54 INCHES
60 INCHES
3 INCHES
3 INCHES
4 INCHES
4 INCHES
5 INCHES
5 INCHES
6 INCHES
2 INCHES
3 INCHES
4 INCHES
5 INCHES
6 INCHES
6 INCHES
6 INCHES
8 INCHES8 INCHES
D
L
W
COMMUNICATIONS SERVICE
JACK/OUTLET
HORIZONTAL DISTRIBUTION
CABLING
TR/LVSR ROOM
POE SWITCHING BY VA
PATCH CORDS
PATCH PANEL AT TR/LVSR
ROOM
COMMUNICATIONS EQUIPMENT BY VA
LINE CORDS
COMMUNICATIONS EQUIPMENT BY VA
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN003
BUILDING 04 LOW VOLTAGE DETAILS
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
12" = 1'-0"
DOUBLE GANG DEVICE BOX / SINGLE
GANG COVER - GARAGE
12" = 1'-0"
WALL OUTLET DETAIL - PARKING
GARAGE
12" = 1'-0"
TYPICAL BACK BOX DETAIL
12" = 1'-0"
MINIMUM PULL BOX SPACE
REQUIREMENTS
12" = 1'-0"
PERMANENT LINK DIAGRAM
CEILING
FINISHED FLOOR
ACCESSIBLE CEILING
OR ACCESSIBLE PANEL
TYPICAL PARTITION
TYPICAL CONDUIT
SLEEVES
TYPICAL WALL ANGLE
WITH J-BOLTS
TYPICAL CABLE
RUNWAY TRANSISTION
SECTION
SWIVEL BUTT SPLICE
SWIVEL BUTT SPLICE
TYPICAL TR ROOM
C O O R D
IN
A T E W
IT
H E L E V A T
IO
N S
M A X
TYPICAL ADJACENT
SPACE
TYPICAL CABLE RUNWAY
LADDER STYLE
TYPICAL CONDUIT SLEEVE
TYPICAL PARTITION
TYPICAL FRT PLYWOOD
BACKER BOARD - SEE PLANS
ISOMETRIC RUNWAY AT WALL
PROVIDE CAPS AT
ALL CUT/ROUGH
ENDS
WALL ANGLE WITH J-
BOLTS
WALL ANGLE WITH J-
BOLTS
RUNWAY SIZE - SEE
PART PLANS
BUTT SPLICE
" T
YP
IC
AL
1- 1/ 2" T
YP
/8 T Y P
-1 /2 T Y P
3/8" TYP.
CABLE RUNWAY - SEE
PLAN
PERPENDICULAR MOUNTING RUNWAY AT
EQUIPMENT RACK
PARALLEL MOUNTING RUNWAY AT
EQUIPMENT RACK
JUNCTION SPLICE KIT
TYPICAL SECTION
GALVANIZED THREADED ROD -
SECURE TO STRUCTURE
ABOVE
TYPICAL
0' - 7"
GALVANIZED METAL CHANNEL
STRUT WITH INTEGRAL LIP
CONDUIT PIPE CLAMP
4" TRADE SIZE CONDUIT - SEE
PLAN FOR EXACT QUANTITY
T Y P
IC
A L
NOTES:
1. METAL CHANNEL STRUT SUPPORT LONGER THAN 36"
SHALL BE INSTALLED WITH A CENTER SUPPORT ROD.
2. CONDUIT SUPPORT SYSTEM SHALL BE GALVANIZED.
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN004
BUILDING 04 LOW VOLTAGE DETAILS
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
12" = 1'-0"
TYPICAL CABLE RUNWAY TRANSITION
12" = 1'-0"
CABLE RUNWAY SYSTEM
3" = 1'-0"
TYPICAL CONDUIT SUPPORT DETAIL
-MULTIPLE STACKS
UP
FLEET
ENTRY/EXIT
S S
SLOUNGE
1K116
ST
1K116A
ST
1K116B
DISPATCH
CUBICLES
1K114
STP
TRANS
SUPV
1K114A
ELEC
1K108
ATTENDANT
OFFICE
1K112
WC
STOR
1K109
STAIR
STK-1
STAIR
STK-2
STP
HE
N
M
L
K
J
H
G
F
E
D
C
EQUIPMENT
STORAGE
1K105
TELECOM
1K104
SECURITY
1K106
SECURITY
1K101
TEL-DATA
1K103
MECHANICAL
1K110
G7
4AS101K
4AI410
2AI101G
4AS101K
1.4
3.6
C
PULL BOX - SEE
PULL BOX DETAIL
FOR SIZES.
(4) 4" TIE
CONDUITS
(3) 4"
SLEEVES
(4) 4" CONDUITS UP
ABOVE CEILING ON
GARAGE 6TH FLOOR:
(2) 4" CONDUITS TO MCR
(2) 4" CONDUITS TO TER
4TN501
4TN501
WL
WWL
W
WL
A A
A A
NOTE 1NOTE 1
NOTE 1NOTE 1
NOTE 2NOTE 2
NOTE 2NOTE 2
TERMINATE CABLES WEST
OF COLUMN LINE H IN TR
1K104 - SEE NOTE 1.
TERMINATE CABLES EAST
OF COLUMN LINE H IN TR
1K103 - SEE NOTE 2.
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN101-K
BUILDING 04 TELECOM FIRST FLOOR PARKING
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
1/16" = 1'-0"
BUILDING 04 TELECOM LEVEL ONE
DEVICE COUNT FIRST FLOOR
OUTLET SUBSCRIPT
VOICE
PORTS
DATA
PORTS
OUTLET
COUNT
DATA
PANELS
VOICE
PANELS
Standard
10 10 5 0.21 0.21
Wall Phone
WALL PHONE W 2 0 2 0 0.04
Wireless
WL 0 6 3 0.13 0
12 16 10 0.33 0.25
NOTES:
1. VERTICAL SPACE BETWEEN PRECAST PANELS ALONG STICH WALL RESERVED
FOR TELECOM AND SECURITY CONDUITS WEST OF COLUMN H.
2. VERTICAL SPACE BETWEEN PRECAST PANELS ALONG STICH WALL RESERVED
FOR TELECOM AND SECURITY CONDUITS EAST OF COLUMN H.
DN
UP
DN
S
FEC
FEC
FECFEC
FEC
PARKING
LEVEL 2 AT
EL 114'-8"
OPEN TO
CONCOURSE
LEVEL 1 AT
EL 100'-0"
STAIR
STK-1
STAIR
STK-2
STP
STP
5" EJ
HE
CC
BB
AA
N
M
L
K
J
H
G
F
E
D
C
6.8
7.3
SANITARY TANK -
SEE STRUC
4AS102K
4AI410
FEC
FEC
RAMP
1.4
3.6
OPP
OPP
ROW 2
ROW 1
ROW 3
TERMINATE CABLES WEST
OF COLUMN LINE H IN TR
1K104 - SEE NOTE 1.
TERMINATE CABLES EAST
OF COLUMN LINE H IN TR
1K103 - SEE NOTE 2.
WL W
A A
NOTE 1NOTE 1
NOTE 1NOTE 1
NOTE 2NOTE 2
NOTE 2NOTE 2
Q
D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN102-K
BUILDING 04 TELCOM SECOND PARKING LEVEL
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
1/16" = 1'-0"
BUILDING 04 - TELCOM LEVEL TWO
DEVICE COUNT SECOND FLOOR
OUTLET SUBSCRIPT
DATA
PORTS
VOICE
PORTS
OUTLET
COUNT
DATA
PANELS
VOICE
PANELS
COVERAGE ANTENNA-16TH INCH PLANS
COVERAGE ATENNA A 0 0 2 0 0
Wall Phone
WALL PHONE W 0 1 1 0 0.02
Wireless
WL 2 0 1 0.04 0
2 1 4 0.04 0.02
NOTES:
1. VERTICAL SPACE BETWEEN PRECAST PANELS ALONG STICH WALL RESERVED
FOR TELECOM AND SECURITY CONDUITS WEST OF COLUMN H.
SPARKING
LEVEL 4
ELEV = 138'-0"
CONCOURSE
LEVEL 3
ELEV = 138'-0"
FEC
FEC
FECFEC
FEC
STP
STP
STAIR
STK-2
STAIR
STK-1
5" EJ
FEC
HE
CC
BB
AA
N
M
L
K
J
H
G
F
E
D
C
6.8
7.3
4AS104K
4AI411
RAMP
1.4
3.6
OPP
OPP
RAMP DNRAMP UP
RAMP UP
RAMP DN
SLOPE DOWN
FD
FD
FD
ROW 2
ROW 1
ROW 3A A
WWL
NOTE 1NOTE 1
NOTE 1NOTE 1
NOTE 2NOTE 2
NOTE 2NOTE 2
TERMINATE CABLES WEST
OF COLUMN LINE H IN TR
1K104 - SEE NOTE 1.
TERMINATE CABLES EAST
OF COLUMN LINE H IN TR
1K103 - SEE NOTE 2.
Q
D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN103-K
BUILDING 04 TELCOM THIRD PARKING LEVEL
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
1/16" = 1'-0"
BUILDING 04 TELCOM LEVEL THREE
DEVICE COUNT THIRD FLOOR
OUTLET SUBSCRIPT
DATA
PORTS
VOICE
PORTS
OUTLET
COUNT
DATA
PANELS
VOICE
PANELS
COVERAGE ANTENNA-16TH INCH PLANS
COVERAGE
ATENNA
A 0 0 2 0 0
Wall Phone
WALL PHONE W 0 1 1 0 0.02
Wireless
WL 2 0 1 0.04 0
2 1 4 0.04 0.02
NOTES:
1. VERTICAL SPACE BETWEEN PRECAST PANELS ALONG STICH WALL RESERVED
FOR TELECOM AND SECURITY CONDUITS WEST OF COLUMN H.
ELEV = 138'-0"
CONCOURSE
LEVEL 3
ELEV = 138'-0"
FEC
FEC
FECFEC
FEC
STP
STP
STAIR
STK-2
STAIR
STK-1
5" EJ
FEC
HE
CC
BB
AA
N
M
L
K
J
H
G
F
E
D
C
6.8
7.3
4AS104K
4AI411
RAMP
1.4
3.6
OPP
OPP
RAMP DNRAMP UP
RAMP UP
RAMP DN
SLOPE DOWN
FD
FD
FD
ROW 2
ROW 1
ROW 3
A A
WL W
NOTE 1NOTE 1
NOTE 1NOTE 1
NOTE 2NOTE 2
NOTE 2NOTE 2
ACCESSIBLE
PULL BOX
(4) 4" CONDUITS
UP TO LEVEL 6
TERMINATE CABLES WEST
OF COLUMN LINE H IN TR
1K104 - SEE NOTE 1.
TERMINATE CABLES EAST
OF COLUMN LINE H IN TR
1K103 - SEE NOTE 2.
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN104-K
BUILDING 04 TELCOM FOURTH PARKING LEVEL
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
1/16" = 1'-0"
BUILDING 04 TELCOM LEVEL FOUR
DEVICE COUNT FOURTH FLOOR
OUTLET SUBSCRIPT
DATA
PORTS
VOICE
PORTS
OUTLET
COUNT
DATA
PANELS
VOICE
PANELS
COVERAGE ANTENNA-16TH INCH PLANS
COVERAGE
ATENNA
A 0 0 2 0 0
Wall Phone
WALL PHONE W 0 1 1 0 0.02
Wireless
WL 2 0 1 0.04 0
2 1 4 0.04 0.02
NOTES:
1. VERTICAL SPACE BETWEEN PRECAST PANELS ALONG STICH WALL RESERVED
FOR TELECOM AND SECURITY CONDUITS WEST OF COLUMN H.
DN
UP
SPARKING
LEVEL 5
ELEV = 148'-8"
STP
STP
STAIR
STK-2
STAIR
STK-1
5" EJ
HE
CC
BB
AA
N
M
L
K
J
H
G
F
E
D
C
6.8
5K-STK2-1
5K-STK1-1
4AS105K
4AI411
RAMP
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
1.4
3.6
OPP
OPP
RAMP DNRAMP UP
RAMP UP
RAMP DN
SLOPE DOWN
FD
FD
FD
E-K5-100
ROW 2
ROW 1
ROW 3A A
WWL
NOTE 1NOTE 1
NOTE 1NOTE 1
NOTE 2NOTE 2
NOTE 2NOTE 2
(4) 4"
CONDUITS UP
TO LEVEL 6
TERMINATE CABLES WEST
OF COLUMN LINE H IN TR
1K104 - SEE NOTE 1.
TERMINATE CABLES EAST
OF COLUMN LINE H IN TR
1K103 - SEE NOTE 2.
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN105-K
BUILDING 04 TELCOM FIFTH PARKING LEVEL
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
1/16" = 1'-0"
BUILDING 04 TELCOM LEVEL FIVE
DEVICE COUNT FIFTH FLOOR
OUTLET SUBSCRIPT
DATA
PORTS
VOICE
PORTS
OUTLET
COUNT
DATA
PANELS
VOICE
PANELS
COVERAGE ANTENNA-16TH INCH PLANS
COVERAGE
ATENNA
A 0 0 2 0 0
Wall Phone
WALL PHONE W 0 1 1 0 0.02
0 1 3 0 0.02
NOTES:
1. VERTICAL SPACE BETWEEN PRECAST PANELS ALONG STICH WALL RESERVED
FOR TELECOM AND SECURITY CONDUITS WEST OF COLUMN H.
DN
UP
DNDN
FEC
FEC
FEC
FEC
FEC
PARKING
LEVEL 6
ELEV = 159'-4"
STP
STP
STAIR
STK-2
STAIR
STK-1
5" EJ
FEC
HE
CC
BB
AA
N
M
L
K
J
H
G
F
E
D
C
6.8
6K-STK2-1
6K-STK1-1
7.3
4AS106K
4AI411
RAMP
1.4
3.6
OPP
OPP
RAMP DNRAMP UP
RAMP UP
RAMP DN
SLOPE DOWN
FD
FD
FD
ROW 2
ROW 1
ROW 3
A A
WL W
A A
A
NOTE 1NOTE 1
NOTE 1NOTE 1
NOTE 2NOTE 2
NOTE 2NOTE 2
TERMINATE CABLES WEST
OF COLUMN LINE H IN TR
1K104 - SEE NOTE 1.
TERMINATE CABLES EAST
OF COLUMN LINE H IN TR
1K103 - SEE NOTE 2.
Q
D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN106-K
BUILDING 04 TELCOM SIXTH PARKING LEVEL
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
1/16" = 1'-0"
BUILDING 04 TELCOM LEVEL SIX
DEVICE COUNT SIXTH FLOOR
OUTLET SUBSCRIPT
DATA
PORTS
VOICE
PORTS
OUTLET
COUNT
DATA
PANELS
VOICE
PANELS
COVERAGE ANTENNA-16TH INCH PLANS
COVERAGE
ATENNA
A 0 0 4 0 0
Wall Phone
WALL PHONE W 0 1 1 0 0.02
Wireless
WL 2 0 1 0.04 0
2 1 6 0.04 0.02
NOTES:
1. VERTICAL SPACE BETWEEN PRECAST PANELS ALONG STICH WALL RESERVED
FOR TELECOM AND SECURITY CONDUITS WEST OF COLUMN H.
ELEV = 138'-0"
FEC
FEC
FECFEC
FEC
STP
STP
STAIR
STK-2
STAIR
STK-1
5" EJ
FEC
HE
CC
BB
AA
N
M
L
K
J
H
G
F
E
D
C
6.8
7.3
4AS104K
4AI411
RAMP
1.4
3.6
OPP
OPP
RAMP DNRAMP UP
RAMP UP
RAMP DN
SLOPE DOWN
FD
FD
FD
TERMINATE CABLES WEST
OF COLUMN LINE H IN TR
1K104 - SEE NOTE 1.
TERMINATE CABLES EAST
OF COLUMN LINE H IN TR
1K103 - SEE NOTE 2.
WWL
A A
A A
NOTE 1NOTE 1
NOTE 1NOTE 1
NOTE 2NOTE 2
NOTE 2NOTE 2
Q
D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN107-K
BUILDING 04 TELCOM SEVENTH PARKING
LEVEL
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
1/16" = 1'-0"
BUILDING 04 TELCOM LEVEL SEVEN
DEVICE COUNT SEVENTH FLOOR
OUTLET SUBSCRIPT
DATA
PORTS
VOICE
PORTS
OUTLET
COUNT
DATA
PANELS
VOICE
PANELS
COVERAGE ANTENNA-16TH INCH PLANS
COVERAGE
ATENNA
A 0 0 4 0 0
Wall Phone
WALL PHONE W 0 1 1 0 0.02
Wireless
WL 2 0 1 0.04 0
2 1 6 0.04 0.02
NOTES:
1. VERTICAL SPACE BETWEEN PRECAST PANELS ALONG STICH WALL RESERVED
FOR TELECOM AND SECURITY CONDUITS WEST OF COLUMN H.
UP DN
PARKING
LEVEL 4
ELEV = 138'-0"
CONCOURSE
LEVEL 3
ELEV = 138'-0"
STP
STP
STAIR
STK-2
STAIR
STK-1
5" EJ
CC
BB
AA
N
M
L
K
J
H
G
F
E
D
C
6.8
7.3
4AS104K
4AI411
RAMP
1.4
3.6
OPP
OPP
8" PIPE BOLLARD, TYP. OF 3
RAMP DNRAMP UP
RAMP UP
RAMP DN
SLOPE DOWN
FD
FD
FD
NOTE 1NOTE 1
NOTE 1NOTE 1
NOTE 2NOTE 2
NOTE 2NOTE 2
TERMINATE CABLES WEST
OF COLUMN LINE H IN TR
1K104 - SEE NOTE 1
TERMINATE CABLES EAST
OF COLUMN LINE H IN TR
1K103 - SEE NOTE 2.
4TN108-K
C
ELEVATOR
MACHINE
ROOM
8K101
MECHANICAL
PENTHOUSE
8K100
8K101
8K -1
E
E
E
WORK AREA OUTLETS FOR
ELEVATOR CONTROL PANELS
PROVIDED UNDER WP-8.
CABLING TO EXTEND TO BLD 3
OUTPATIENT LEVEL 4 TR WITHIN
CABLE ZONE J1. COORDINATE
LOCATION AND ROUGH-IN WITH
ELEVATOR CONTRACTOR PRIOR
TO WORK.
E
Q
D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN108-K
BUILDING 04 TELCOM LEVEL EIGHT
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
1/16" = 1'-0"
BUILDING 04 TELCOM LEVEL EIGHT
DEVICE COUNT EIGHTH FLOOR
OUTLET SUBSCRIPT
DATA
PORTS
VOICE
PORTS
OUTLET
COUNT
DATA
PANELS
VOICE
PANELS
Wall Phone
ELEVATOR E 4 0 4 0.08 0
4 0 4 0.08 0
NOTES:
1. VERTICAL SPACE BETWEEN PRECAST PANELS ALONG STICH WALL RESERVED
FOR TELECOM AND SECURITY CONDUITS WEST OF COLUMN H.
2. VERTICAL SPACE BETWEEN PRECAST PANELS ALONG STICH WALL RESERVED
FOR TELECOM AND SECURITY CONDUITS EAST OF COLUMN H.
1/8" = 1'-0"
BUILDING 4 ELEVATOR MACHINE ROOM
PART PLAN
10 BULLETIN 011D 05/31/13
300 PAIR 110 BLOCK FOR VOICE RISER CABLE.
300 PAIR 110 BLOCK FOR VOICE STATION CABLES.
TELECOMMUNICATIONS GROUNDING BAR.
VERTICAL WIRE MANAGER, 84" H x 6" W.
2 POST NETWORK EQUIPMENT RACK, 84" H x 19" W.
INTELLIGENT MULTIMODE FIBER PATCH PANEL, 1RU.
INTELLIGENT SINGLEMODE FIBER PATCH PANEL, 1RU.
10 kVA UPS, RACK MOUNTED. PROVIDED BY VA.
HORIZONTAL WIRE MANAGER, 2RU.
INTELLIGENT CAT6A ANGLED PATCH PANEL, 48 PORT 2RU.
INTELLIGENT PATCH PANEL SCANNER SWITCH, 1RU.
D-RINGS, 4" METAL
PLYWOOD, AC GRADE FIRE RETARDANT. PAINT WITH LIGHT COLOR.
DO NOT PAINT OVER FIRE RATING STAMP. MOUNT 12" AFF TO 9' AFF ON ALL WALLS.
4" HORIZONTAL SLEEVES.
TELECOMMUNICATIONS KEYNOTES
15 WALL PHONE
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN500
BUILDING 04 TELECOMMUNICATIONS
KEYNOTES
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
W
4TN501 4
4TN501 6
R A
C K
R
A C
K
R A
C K
K
W
4TN501 3
4TN501 5
R A
C K
R
A C
K
R A
C K
7.9
BLDG 4 SECURITY
LEVEL TWO
114' � 8"
BLDG 4 FIRST
FLOOR PLAN
100' � 0"
BLDG 4 SECOND
PARKING LEVEL
112' � 8"
BLDG 4 FIRST
FLOOR PLAN
100' � 0"
BLDG 4 FIRST
FLOOR PLAN
100' � 0"
RACK 3 RACK 2 RACK 1
4TN502
4TN502
BLDG 4 FIRST
FLOOR PLAN
100' � 0"
RACK 1 RACK 2 RACK 3
4TN502
4TN502
4TN502
4TN502
4TN502
4TN502
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN501
BUILDING 04 TELECOM PART PLANS AND
ELEVATIONS
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
1/2" = 1'�0"
TELECOM PART PLAN RM.NO 1K103
1/2" = 1'�0"
TELECOM PART PLAN RM. NO 1K104
1/2" = 1'�0"
1K104 TELECOMM WALL FIELD
1/2" = 1'�0"
1K103 TELECOMM WALL FIELD
1" = 1'�0"
1K104 RACK ELEVATION
1" = 1'�0"
1K103 RACK ELEVATION
5 ADDENDUM # 5 � POST BID 11/30/11
BLANK PLATE
(6) DUPLEX LC OM4 � TR VOICE
(6) DUPLEX LC OM4 � TR VOICE
(6) DUPLEX LC SM � TR VOICE
(6) DUPLEX LC SM � TR VOICE
BLANK PLATE
BLANK PLATE
(6) DUPLEX LC OM4 � TR DATA
(6) DUPLEX LC OM4 � TR DATA
(6) DUPLEX LC SM � TR DATA
(6) DUPLEX LC SM � TR DATA
BLANK PLATE
BLANK PLATE
(6) QUAD LC SM TO 1K104 � VOICE
(6) QUAD LC OM4 TO 1K104 � VOICE
BLANK PLATE
(6) QUAD LC SM TO MCR � VOICE
(6) QUAD LC OM4 TO MCR � VOICE
BLANK PLATE
(6) QUAD LC SM TO 1K104 � DATA
(6) QUAD LC OM4 TO 1K104 � DATA
BLANK PLATE
(6) QUAD LC SM TO MCR � DATA
(6) QUAD LC OM4 TO MCR � DATA
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN502
BUILDING 04 - TELECOMMUNICATIONS FIBER
DETAILS
JLE JJPNovember 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
5 ADDENDUM # 5 � POST BID 11/30/11
3" = 1'�0"
GARAGE 4 TR VOICE LIU
3" = 1'�0"
GARAGE 4 TR DATA LIU
3" = 1'�0"
GARAGE 4 VOICE RISER MCC LIU
3" = 1'�0"
GARAGE 4 VOICE MCC TO MCR LIU
3" = 1'�0"
GARAGE 4 DATA RISER MCC LIU
3" = 1'�0"
GARAGE 4 DATA MCC TO MCR LIU
STAFF GARAGE BUILDING NUMBER 04
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
(4) 4" TIE CONDUITS.
PROVIDE (3) 1" INNERDUCTS
IN (2) OF THE 4" CONDUITS.
TR:
1K103
NOTES:
PROVIDE GROUNDING BUSHINGS AND NO.6 GREEN GROUND CABLE
FROM TELECOMMUNICATIONS GROUND BUS BAR TO ALL SLEEVES AND
CONDUIT IN TR.
TR:
1K104
FIRST FLOOR FIRST FLOOR
SEVENTH FLOOR SEVENTH FLOOR
(4) 4" CONDUITS
(2) TO MCR
(2) TO TER
PROVIDE (3) 1" INNERDUCTS
IN (2) OF THE 4" CONDUITS TO MCR.
1" CONDUIT TO
COMMUNICATIONS
DEVICE (TYPICAL) -
SEE PLANS FOR
EXACT QUANTITY
1" CONDUIT TO
COMMUNICATIONS
DEVICE (TYPICAL) -
SEE PLANS FOR
EXACT QUANTITY
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN601
LOW VOLTAGE CONDUIT RISER DIAGRAM
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
FIRST FLOOR FIRST FLOOR
SEVENTH FLOOR SEVENTH FLOOR
(48) SINGLEMODE AND (48) MULTIMODE 50 MICRON
OM4 HYBRID FIBEROPTIC CABLE.
LIULIU
(24) SINGLEMODE AND (24) MULTIMODE 50 MICRON
OM4 FIBEROPTIC CABLE.
TR:
1K103
TR:
1K104
(24) SINGLEMODE AND (24) MULTIMODE 50 MICRON OM4
FIBEROPTIC CABLE.
TERMINATE CABLES IN DNT MCR.
REFERENCE 2TN512 FOR INFORMATION.
LIU
LIU
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN602
DATA BACKBONE RISER DIAGRAM
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
4 ADDENDUM #4 08/05/11
5 ADDENDUM # 5 % POST BID 11/30/11
NOTE:
1.
2. ALL FIBER OPTIC CABLES SHALL BE
ARMOR CLAD. 5
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
FIRST FLOOR FIRST FLOOR
SEVENTH FLOOR SEVENTH FLOOR
(48) SINGLEMODE AND (48) MULTIMODE 50 MICRON
OM4 FIBEROPTIC CABLE.
LIULIU
(24) SINGLEMODE AND (24) MULTIMODE 50
MICRON OM4 FIBEROPTIC CABLE.
TR:
1K103
TR:
1K104
TERMINATE CABLES IN DNT MCR.
REFERENCE 2TN512 FOR INFORMATION.
LIU
LIU
(24) SINGLEMODE AND (24) MULTIMODE 50
MICRON OM4 FIBEROPTIC CABLE. 5
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN603
SPECIAL SYSTEMS BACKBONE RISER DIAGRAM
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
4 ADDENDUM #4 08/05/11
5 ADDENDUM # 5 $ POST BID 11/30/11
NOTE:
1.
2. ALL FIBER OPTIC CABLES SHALL BE ARMOR CLAD.
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
FIRST FLOOR FIRST FLOOR
SEVENTH FLOOR SEVENTH FLOOR
100 PAIR CATEGORY 3 VOICE CABLE.
TERMINATE CABLE IN DNT MCR. REFERENCE
2TN511 FOR INFORMATION.
100 PAIR CATEGORY 3 VOICE CABLE
TR:
1K103
TR:
1K104
100 PAIR CATEGORY 3 VOICE CABLE
STATION
CABLES
RISER
CABLE
STATION
CABLES
RISER
CABLE
RISER
CABLE
(24) SINGLEMODE AND (24) MULTIMODE
50 MICRON OM4 FIBEROPTIC CABLE.
LIU LIU
(48) SINGLEMODE AND (48) MULTIMODE 50
MICRON OM4 FIBEROPTIC CABLE.
TERMINATE CABLES IN DNT TER ROOM.
LIU
LIU
(24) SINGLEMODE AND (24) MULTIMODE 50 MICRON OM4
FIBEROPTIC CABLE.
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4TN604
LOW VOLTAGE VOICE BACKBONE CABLING
RISER DIAGRAM
JLE JJPJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
4 ADDENDUM #4 08/05/11
5 ADDENDUM # 5 % POST BID 11/30/11
NOTE:
1. ALL FIBER OPTIC CABLES SHALL BE ARMOR CLAD.
FIRST FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
TR:
1K104
SECURITY:
1K106
TR:
1K103
SECURITY:
1K101
AMP
S
TYP. 70V OVERHEAD PAGING
SYSTEM SPEAKER - SEE TN
PLANS FOR QNTY. & LOCATION
S
S
S
S
S
AMP
S S
CONNECT VOICE LOOP TRUNK PORT
PER MANUFACTURERS INSTRUCTIONS
CONNECT VOICE LOOP TRUNK PORT
PER MANUFACTURERS INSTRUCTIONS
STAFF GARAGE BUILDING NUMBER 04
SEVENTH FLOOR SEVENTH FLOOR
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .