0243-5AS107-L.pdf
PDF 312 KB Posted
- Solicitation number
- 36C25625R0084
About this file
This architectural drawing is a floor plan for Building 5, Level 7 parking level, dated June 20, 2011, prepared for the Office of Construction, Maintenance, and Facilities in New Orleans, Louisiana. The technical drawing shows a detailed floor layout with grid lines, elevation markers, and specific notation for various architectural elements including stairs, ramps, and expansion joints. The drawing includes multiple consultant credits from engineering firms such as Schrenk & Peterson, Korda/Nemeth Engineering, and BR+A Consulting Engineers, among others. The document contains several revision and request for information (RFI) notations, including RFIs related to tank/garage/lobby interface and security screen revisions, with addendum dates ranging from July 2011 to January 2012 and a bulletin from May 2013.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
DN
DN
CONCOURSE
LEVEL 4i
UTILITY LEVEL
ELEV = 168'-4"
PARKING
LEVEL 7
ELEV = 166'-0"
STP
STP
STAIR
STL-1
STAIR
STL-2
5AI401
E5
5AI402
F6
C
D
E
F
G
H
J
K
L
M
N
SEE DWG 1/5AS108-L FOR
ROOF PLAN OF STAIR #1
SEE DWG 2/AS108-L FOR
ROOF PLAN OF STAIR #2
5A I41
5A
S10 7-L
00AI104i-A6 00AI104i-A7
AI
4i
-A
5A I4
RAMP
3.6
5" EJ
SEE DET C3 ON DWG
0A5201 FOR TYP LIGHTING
LAYOUT ON STAIR
WALLS THIS LEVEL
SEE DET C3 ON DWG
0A5201 FOR TYP LIGHTING
LAYOUT ON STAIR
WALLS THIS LEVEL
0AS507B3
B1
5AS108-L
F6
0AS507B6
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
5AS107-L
BLDG 5 OVERALL SEVENTH PARKING LEVEL
DV MAGJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MAINTENANCE
EWP_04
SCALE: 1/16" = 1'-0"1 BLDG 5 LEVEL 7
1. GENERAL PARTITION TYPES: REFER TO SHEET 0AS002 FOR PARTITION
SCHEDULE AND GENERAL PARTITION TYPE NOTES.
2. ENLARGED PLANS: REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN
VIEWS INCLUDING MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.
3. RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH POCHE DENOTING
HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO
PARTITION TAGS ON FLOOR PLANS AND PARITION SCHEDULE SHEET 0AS002
FOR MORE INFORMATION.
4. DIMENSIONS: UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISH
FACE.
5. PIPE GUARDS: PROVIDE PIPE GUARDS AT ALL PIPE AND CONDUIT
EXPOSED TVEHICULAR TRAFFIC. SEE E5/0AS510 FOR DETAILS.
6. LIGHTING: REFER TO ELECTRICAL DRAWINGS FOR GARAGE LIGHTING
LAYOUT.
7. POLE LIGHTING: LEVEL 7 POLE MOUNTED LIGHTS - REFER TO 4D/4SJ502
FOR POLE MOUNTING DETAIL AT COLUMN AND DETAILS 2D, 2E, & 3C/4SJ504
FOR PCC POLE SUPPORT FOR LIGHTS LOCATED IN GAPS BETWEEN STITCH
WALLS
8. BOLLARDS: REFER TO DETAILS 2F, 4F, & 5F/4SJ502 FOR BOLLARD
MOUNTING AT ELEVATED SLABS AND DETAILS 7&8/4SJ013 FOR BOLLARD
MOUNTING AT SOG
GENERAL FLOOR PLAN NOTES
NOTE: FIRE EXTINGUISHER CABINETS
HAVE BEEN REMOVED FROM EWP-04
2 ADDENDUM #2 JULY 29, 2011
4 ADDENDUM #4 AUGUST 5, 2011
6 ADDENDUM #6 - POST BID JANUARY 27, 2012
10 BULLETIN 011D MAY 31, 2013
RFI 05859: Interface of Tank/Garage/Lobby
RFI-06885: Security Screen Revision.
B1/0AS507 is deleted
RFI-06885: Security Screen Revision
RFI 06640: References F1/R0AS557 for the vertical EJ detail
File details come from the government source that posted it. Updated .