0210-4AS101-K.pdf
PDF 669 KB Posted
- Solicitation number
- 36C25625R0084
About this file
This PDF document is an architectural floor plan for Building 4, Level 1, showing a detailed first parking concourse level design. The drawing includes multiple room designations such as Equipment Storage, Telecom, Security, Mechanical, and various stairs and entry points. The plan features gridlines, scale references, and annotations for specific design elements like waterproofing treatments, exterior light locations, and traffic control signage. The document includes revision notes from multiple addendum dates between July 2011 and May 2013, and lists multiple consulting engineering firms involved in the project, including Schrenk & Peterson, Korda/Nemeth Engineering, and BR+A Consulting Engineers. Specific revision requests include moving a partition, clarifying exterior light locations, and providing traffic control signage.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U
UP
4AS302
C6
4AS301
LOUNGE
1K116
ST
1K116A
ST
1K116B
DISPATCH
CUBICLES
1K114
PARKING
LEVEL 1
ELEV = 100'-0"
CONCOURSE
LEVEL 1
ELEV = 100'-0"
STP
4AI401
C5
FEC
TRANS
SUPV
1K114A
ELEC
1K108
ATTENDANT
OFFICE
1K112
WC
STOR
1K109
STAIR
STK-1
STAIR
STK-2
STP
5" EJ
FLEET
ENTRY
STAFF
ENTRY
TL
ENTRY
4AI403
C5
4AI402
C5
N
M
L
K
J
H
G
F
E
D
C
EQUIPMENT
STORAGE
1K105
E6
4AS301
TELECOM
1K104
SECURITY
1K106
SECURITY
1K101 TEL-DATA
1K103
4AI402
C6
4AS202
4AS201
4AS205
4AS204
4AS2031
4AS208
D5
4AS208D6
4AS208 D2
4AS207 D6
1K
MECHANICAL
1K110
G7
SANITARY TANK -
SEE STRUCT
F3
4AS311
F5
4AS311
F2
4AS311
4AS101K
4AI410
00AI101-A5
00AI101-A6
2AI101G
4AS101K
7' -2
3'-4" 13'-0"6'-8"
W_1
W_1
1K123
1K124
1.4
3.6
0AS508
F4
D3 7' -1
/2
'-2
/2
W_1
W_1
TYP @ PCC
LITE WALL PANEL
OPENINGS
TYP @ OPENINGS
BETWEEN PCC
LITE WALL PANELS
.0
0°
0AS508
F6
0AS508
D6
D5
1'-3"
ACCESS LADDER F3
4AI404
0AF601
B4
0IF401
C4
0AF601
B2
4AI402
F6
SEE STRUCTURAL DRAWINGS FOR
LOCATION & QUANTITY OF
BOLLARDS, ALL LEVELS THIS LOCATION
RAMP
SEE DET D3/0AS201 FOR EXTERIOR
LIGHT LOCATION ABOVE DOOR:TYP
AT ALL EXTERIOR GRADE LEVEL EXIT
DOORS
Z0558Z0558 Z0558 Z0558 Z0558
1K
S_
F6
4AI404
4AI402
D6
3-VERTICAL SURFACES & SLAB AREA DEFINED BY
HATCH TO BE TREATED WITH WATER PROOFING AS
DEFINED IN SPECIFICATION SECTION 07 10 00.
VERTICAL SURFACES TREATED TO A HEIGHT OF 98'-6"
EQUIPMENT
STORAGE
1K107
STAIR
STK-3
STAIR
STK-4
W_1W_1 W_1
60AS507
C3
CK-GATE-CASEWK_GATE-200
1K128
OIL /
WATER
INTERCEPTOR
1K128
'-0 "10
1K126
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4AS101-K
BLDG 4 OVERALL FIRST PARKING LEVEL AND
CONCOURSE FIRSTLEVEL
DV MAGJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MAINTENANCE
EWP_04
SCALE: 1/16" = 1'-0"1 BLDG 4 LEVEL 1
1. GENERAL PARTITION TYPES: REFER TO SHEET 0AS002 FOR PARTITION
SCHEDULE AND GENERAL PARTITION TYPE NOTES.
2. ENLARGED PLANS: REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN
VIEWS INCLUDING MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.
3. RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH POCHE DENOTING
HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO
PARTITION TAGS ON FLOOR PLANS AND PARITION SCHEDULE SHEET 0AS002
FOR MORE INFORMATION.
4. DIMENSIONS: UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISH
FACE.
5. PIPE GUARDS: PROVIDE PIPE GUARDS AT ALL PIPE AND CONDUIT
EXPOSED TVEHICULAR TRAFFIC. SEE E5/0AS510 FOR DETAILS.
6. LIGHTING: REFER TO ELECTRICAL DRAWINGS FOR GARAGE LIGHTING
LAYOUT.
7. POLE LIGHTING: LEVEL 7 POLE MOUNTED LIGHTS - REFER TO 4D/4SJ502
FOR POLE MOUNTING DETAIL AT COLUMN AND DETAILS 2D, 2E, & 3C/4SJ504
FOR PCC POLE SUPPORT FOR LIGHTS LOCATED IN GAPS BETWEEN STITCH
WALLS
8. BOLLARDS: REFER TO DETAILS 2F, 4F, & 5F/4SJ502 FOR BOLLARD
MOUNTING AT ELEVATED SLABS AND DETAILS 7&8/4SJ013 FOR BOLLARD
MOUNTING AT SOG
GENERAL FLOOR PLAN NOTES
NOTE: FIRE EXTINGUISHER CABINETS
HAVE BEEN REMOVED FROM EWP-04
2 ADDENDUM #2 JULY 29, 2011
4 ADDENDUM #4 AUGUST 5, 2011
6 ADDENDUM #6 - POST BID JANUARY 27, 2012
7 BULLETIN 005 APRIL 24, 2012
10 BULLETIN 011D MAY 31, 2013
RFI-04759 : S18 Partition to move south and set along the angled CIP knee wall
RFI-04756 : Exterior Light Location Clarification
CR
RFI 07592
RFI 07821
RFI 07923: Provide traffic control signage per RFI response.
File details come from the government source that posted it. Updated .