This PDF document is an architectural floor plan for Building 4, Level 1, showing a detailed first parking concourse level design. The drawing includes multiple room designations such as Equipment Storage, Telecom, Security, Mechanical, and various stairs and entry points. The plan features gridlines, scale references, and annotations for specific design elements like waterproofing treatments, exterior light locations, and traffic control signage. The document includes revision notes from multiple addendum dates between July 2011 and May 2013, and lists multiple consulting engineering firms involved in the project, including Schrenk & Peterson, Korda/Nemeth Engineering, and BR+A Consulting Engineers. Specific revision requests include moving a partition, clarifying exterior light locations, and providing traffic control signage.

View the file

Other files

File Type Posted
0211-4AS102-K.pdf PDF
NOVA VOLUME 2-Low Voltage_2013_0930.pdf PDF
NOVA VOLUME 2-Fire Protection_2013_0930.pdf PDF
629-25-100 Phase 1 RFI Register 05212025.docx DOCX document
0238-5AS102-L.pdf PDF
0216-4AS107-K.pdf PDF
0240-5AS104-L.pdf PDF
NOVA VOLUME 2-Security_2013_0930.pdf PDF
NOVA VOLUME 2-Plumbing Tanks_2013_0930.pdf PDF
NOVA VOLUME 2-Plumbing_2013_0930.pdf PDF
NOVA VOLUME 2-Mechanical_2013_0930.pdf PDF
0243-5AS107-L.pdf PDF
NOVA VOLUME 1_2013_0930.pdf PDF
NOVA VOLUME 2-Electrical_2013_0930.pdf PDF
0237-5AS101-L.pdf PDF
36C25625R0084 0001.docx DOCX document
0213-4AS104-K.pdf PDF
36C25625R0084 VA Patient Garage Report .pdf PDF
36C25625R0084 EXHIBIT F.docx DOCX document
36C25625R0084 01 00 00 General Requirements 03272025 .docx DOCX document
36C25625R0084 EXHIBIT C.docx DOCX document
36C25625R0084 RFP.docx DOCX document
36C25625R0084 EXHIBIT B.docx DOCX document
36C25625R0084 EXHIBIT A.docx DOCX document
36C25625R0084 01 35 26 Safety Requirements 03262025 .docx DOCX document
36C25625R0084 EXHIBIT E.docx DOCX document
36C25625R0084 EXHIBIT D.docx DOCX document
36C25625R0084 VA Staff Garage Report .pdf PDF
36C25625R0084.docx DOCX document
36C25625R0084 629-25-100 SOW 03262025 .docx DOCX document
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U

UP

4AS302

C6

4AS301

LOUNGE

1K116

ST

1K116A

ST

1K116B

DISPATCH

CUBICLES

1K114

PARKING

LEVEL 1

ELEV = 100'-0"

CONCOURSE

LEVEL 1

ELEV = 100'-0"

STP

4AI401

C5

FEC

TRANS

SUPV

1K114A

ELEC

1K108

ATTENDANT

OFFICE

1K112

WC

STOR

1K109

STAIR

STK-1

STAIR

STK-2

STP

5" EJ

FLEET

ENTRY

STAFF

ENTRY

TL

ENTRY

4AI403

C5

4AI402

C5

N

M

L

K

J

H

G

F

E

D

C

EQUIPMENT

STORAGE

1K105

E6

4AS301

TELECOM

1K104

SECURITY

1K106

SECURITY

1K101 TEL-DATA

1K103

4AI402

C6

4AS202

4AS201

4AS205

4AS204

4AS2031

4AS208

D5

4AS208D6

4AS208 D2

4AS207 D6

1K

MECHANICAL

1K110

G7

SANITARY TANK -

SEE STRUCT

F3

4AS311

F5

4AS311

F2

4AS311

4AS101K

4AI410

00AI101-A5

00AI101-A6

2AI101G

4AS101K

7' -2

3'-4" 13'-0"6'-8"

W_1

W_1

1K123

1K124

1.4

3.6

0AS508

F4

D3 7' -1

/2

'-2

/2

W_1

W_1

TYP @ PCC

LITE WALL PANEL

OPENINGS

TYP @ OPENINGS

BETWEEN PCC

LITE WALL PANELS

.0

0°

0AS508

F6

0AS508

D6

D5

1'-3"

ACCESS LADDER F3

4AI404

0AF601

B4

0IF401

C4

0AF601

B2

4AI402

F6

SEE STRUCTURAL DRAWINGS FOR

LOCATION & QUANTITY OF

BOLLARDS, ALL LEVELS THIS LOCATION

RAMP

SEE DET D3/0AS201 FOR EXTERIOR

LIGHT LOCATION ABOVE DOOR:TYP

AT ALL EXTERIOR GRADE LEVEL EXIT

DOORS

Z0558Z0558 Z0558 Z0558 Z0558

1K

S_

F6

4AI404

4AI402

D6

3-VERTICAL SURFACES & SLAB AREA DEFINED BY

HATCH TO BE TREATED WITH WATER PROOFING AS

DEFINED IN SPECIFICATION SECTION 07 10 00.

VERTICAL SURFACES TREATED TO A HEIGHT OF 98'-6"

EQUIPMENT

STORAGE

1K107

STAIR

STK-3

STAIR

STK-4

W_1W_1 W_1

60AS507

C3

CK-GATE-CASEWK_GATE-200

1K128

OIL /

WATER

INTERCEPTOR

1K128

'-0 "10

1K126

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

T E

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F I N

C H

O

N E

FO

O

T

TH

R

EE

Q U

A R

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

( 1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

E S

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

4AS101-K

BLDG 4 OVERALL FIRST PARKING LEVEL AND

CONCOURSE FIRSTLEVEL

DV MAGJUNE 30, 2011

CONSTRUCTION DOCUMENTS 1

629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MAINTENANCE

EWP_04

SCALE: 1/16" = 1'-0"1 BLDG 4 LEVEL 1

1. GENERAL PARTITION TYPES: REFER TO SHEET 0AS002 FOR PARTITION

SCHEDULE AND GENERAL PARTITION TYPE NOTES.

2. ENLARGED PLANS: REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN

VIEWS INCLUDING MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.

3. RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH POCHE DENOTING

HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO

PARTITION TAGS ON FLOOR PLANS AND PARITION SCHEDULE SHEET 0AS002

FOR MORE INFORMATION.

4. DIMENSIONS: UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISH

FACE.

5. PIPE GUARDS: PROVIDE PIPE GUARDS AT ALL PIPE AND CONDUIT

EXPOSED TVEHICULAR TRAFFIC. SEE E5/0AS510 FOR DETAILS.

6. LIGHTING: REFER TO ELECTRICAL DRAWINGS FOR GARAGE LIGHTING

LAYOUT.

7. POLE LIGHTING: LEVEL 7 POLE MOUNTED LIGHTS - REFER TO 4D/4SJ502

FOR POLE MOUNTING DETAIL AT COLUMN AND DETAILS 2D, 2E, & 3C/4SJ504

FOR PCC POLE SUPPORT FOR LIGHTS LOCATED IN GAPS BETWEEN STITCH

WALLS

8. BOLLARDS: REFER TO DETAILS 2F, 4F, & 5F/4SJ502 FOR BOLLARD

MOUNTING AT ELEVATED SLABS AND DETAILS 7&8/4SJ013 FOR BOLLARD

MOUNTING AT SOG

GENERAL FLOOR PLAN NOTES

NOTE: FIRE EXTINGUISHER CABINETS

HAVE BEEN REMOVED FROM EWP-04

2 ADDENDUM #2 JULY 29, 2011

4 ADDENDUM #4 AUGUST 5, 2011

6 ADDENDUM #6 - POST BID JANUARY 27, 2012

7 BULLETIN 005 APRIL 24, 2012

10 BULLETIN 011D MAY 31, 2013

RFI-04759 : S18 Partition to move south and set along the angled CIP knee wall

RFI-04756 : Exterior Light Location Clarification

CR

RFI 07592

RFI 07821

RFI 07923: Provide traffic control signage per RFI response.