About this file

This architectural floor plan document is a detailed design drawing for Building 5, Level 4 of a parking garage project for the Southeast Louisiana Veterans Healthcare System in New Orleans, Louisiana. The drawing, dated June 20, 2011, shows a typical parking level layout (Levels 3-6) with grid lines, elevator locations, and parking level elevations ranging from 123'-4" to 155'-4". The document includes multiple technical consultants such as Schrenk & Peterson (Civil Engineering), Korda/Nemeth Engineering (Structural), and BR+A Consulting Engineers (Mechanical, Electrical, Plumbing), indicating a complex multi-disciplinary design process. The drawing contains several addendum revisions between July 2011 and January 2012, with a final bulletin update in May 2013, suggesting an iterative design development process.

View the file

Other files

File Type Posted
0211-4AS102-K.pdf PDF
NOVA VOLUME 2-Low Voltage_2013_0930.pdf PDF
NOVA VOLUME 2-Fire Protection_2013_0930.pdf PDF
629-25-100 Phase 1 RFI Register 05212025.docx DOCX document
0238-5AS102-L.pdf PDF
0216-4AS107-K.pdf PDF
NOVA VOLUME 2-Security_2013_0930.pdf PDF
NOVA VOLUME 2-Plumbing Tanks_2013_0930.pdf PDF
NOVA VOLUME 2-Plumbing_2013_0930.pdf PDF
NOVA VOLUME 2-Mechanical_2013_0930.pdf PDF
0243-5AS107-L.pdf PDF
0210-4AS101-K.pdf PDF
NOVA VOLUME 1_2013_0930.pdf PDF
NOVA VOLUME 2-Electrical_2013_0930.pdf PDF
0237-5AS101-L.pdf PDF
36C25625R0084 0001.docx DOCX document
0213-4AS104-K.pdf PDF
36C25625R0084 VA Patient Garage Report .pdf PDF
36C25625R0084 EXHIBIT F.docx DOCX document
36C25625R0084 01 00 00 General Requirements 03272025 .docx DOCX document
36C25625R0084 EXHIBIT C.docx DOCX document
36C25625R0084 RFP.docx DOCX document
36C25625R0084 EXHIBIT B.docx DOCX document
36C25625R0084 EXHIBIT A.docx DOCX document
36C25625R0084 01 35 26 Safety Requirements 03262025 .docx DOCX document
36C25625R0084 EXHIBIT E.docx DOCX document
36C25625R0084 EXHIBIT D.docx DOCX document
36C25625R0084 VA Staff Garage Report .pdf PDF
36C25625R0084.docx DOCX document
36C25625R0084 629-25-100 SOW 03262025 .docx DOCX document
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

DN

DN

UP

STP

STP

C

D

E

F

G

H

J

K

L

M

N

5A I41

5A

S10 4-L

00AI102-A6

6AI102-M3

AI

2-

A 6 5A

I4

RAMP

3.6

5" EJ

5AI401

E6

5AI402

F5

PARKING LEVEL 3 ELEV = 123'-4"

PARKING LEVEL 4 ELEV = 134'-0"

PARKING LEVEL 5 ELEV = 144'-8"

PARKING LEVEL 6 ELEV = 155'-4"

GARAGE CONNECTOR ELEVATIONS

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

T E

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F I N

C H

O

N E

FO

O

T

TH

R

EE

Q U

A R

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

( 1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

E S

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

5AS104-L

BLDG 5 TYPICAL PARKING LEVEL

(LEVELS 3 - 6)

DV MAGJUNE 30, 2011

CONSTRUCTION DOCUMENTS 1

629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MAINTENANCE

EWP_04

SCALE: 1/16" = 1'-0"1 BLDG 5 LEVEL 4

1. GENERAL PARTITION TYPES: REFER TO SHEET 0AS002 FOR PARTITION

SCHEDULE AND GENERAL PARTITION TYPE NOTES.

2. ENLARGED PLANS: REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN

VIEWS INCLUDING MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.

3. RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH POCHE DENOTING

HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO

PARTITION TAGS ON FLOOR PLANS AND PARITION SCHEDULE SHEET 0AS002

FOR MORE INFORMATION.

4. DIMENSIONS: UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISH

FACE.

5. PIPE GUARDS: PROVIDE PIPE GUARDS AT ALL PIPE AND CONDUIT

EXPOSED TVEHICULAR TRAFFIC. SEE E5/0AS510 FOR DETAILS.

6. LIGHTING: REFER TO ELECTRICAL DRAWINGS FOR GARAGE LIGHTING

LAYOUT.

7. POLE LIGHTING: LEVEL 7 POLE MOUNTED LIGHTS - REFER TO 4D/4SJ502

FOR POLE MOUNTING DETAIL AT COLUMN AND DETAILS 2D, 2E, & 3C/4SJ504

FOR PCC POLE SUPPORT FOR LIGHTS LOCATED IN GAPS BETWEEN STITCH

WALLS

8. BOLLARDS: REFER TO DETAILS 2F, 4F, & 5F/4SJ502 FOR BOLLARD

MOUNTING AT ELEVATED SLABS AND DETAILS 7&8/4SJ013 FOR BOLLARD

MOUNTING AT SOG

GENERAL FLOOR PLAN NOTES

NOTE: FIRE EXTINGUISHER CABINETS

HAVE BEEN REMOVED FROM EWP-04

2 ADDENDUM #2 JULY 29, 2011

4 ADDENDUM #4 AUGUST 5, 2011

6 ADDENDUM #6 - POST BID JANUARY 27, 2012

10 BULLETIN 011D MAY 31, 2013

File details come from the government source that posted it. Updated .