0211-4AS102-K.pdf
PDF 332 KB Posted
- Solicitation number
- 36C25625R0084
About this file
This document is a detailed architectural floor plan for Building 4, Level 2 parking area, prepared for the Office of Construction and Maintenance at a Veterans Healthcare facility in New Orleans, Louisiana. The architectural drawing, labeled 4AS102-K, shows a comprehensive second-level parking layout with various structural elements including stairs (STK-1, STK-2), ramps, sanitary tanks, and a standing seam metal roof canopy. The plan includes specific technical annotations such as traffic bearing waterproofing membrane locations, grid coordinates, and elevation markers. The drawing is part of a set of construction documents developed by multiple consulting engineers, including Schrenk & Peterson, Korda/Nemeth Engineering, and BR+A Consulting Engineers, with revisions noted from July and August 2011, and a subsequent bulletin in May 2013. A specific request for information (RFI-03259) is referenced regarding canopy steel connection clarification.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U
DN
UP
PARKING
LEVEL 2 AT
EL 114'-8"
OPEN TO
CONCOURSE
LEVEL 1 AT
EL 100'-0"
STAIR
STK-1
STAIR
STK-2
STP
STP
5" EJ
4AI403
C3
4AI402
C3
N
M
L
K
J
H
G
F
E
D
C
SANITARY TANK -
SEE STRUC
4AS108-K
E3
4AS102K
4AI410
00AI101-A5
00AI101-A6
RAMP
1.4
3.6
W_1W_1W_1
OPP
OPP
APPROX. EXTENTS OF TRAFFIC BEARING
WATEPROOFING MEMBRANE; TYP. OF 2
LOCATIONS - SEE SPEC SECTION
07 18 16 FOR MORE INFORMATION
0AS507
C3
STANDING SEAM
MTL ROOF CANOPY
L540K F3
L540K F2
4AS108-K
B6
4AI401
B6
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4AS102-K
BLDG 4 OVERALL SECOND PARKING LEVEL
DV MAGJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MAINTENANCE
EWP_04
SCALE: 1/16" = 1'-0"1 BLDG 4 LEVEL 2
NO DIRECT CONNECTION FROM
PARKING LEVEL 2 TO CONCOURSE
1. GENERAL PARTITION TYPES: REFER TO SHEET 0AS002 FOR PARTITION
SCHEDULE AND GENERAL PARTITION TYPE NOTES.
2. ENLARGED PLANS: REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN
VIEWS INCLUDING MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.
3. RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH POCHE DENOTING
HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO
PARTITION TAGS ON FLOOR PLANS AND PARITION SCHEDULE SHEET 0AS002
FOR MORE INFORMATION.
4. DIMENSIONS: UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISH
FACE.
5. PIPE GUARDS: PROVIDE PIPE GUARDS AT ALL PIPE AND CONDUIT
EXPOSED TVEHICULAR TRAFFIC. SEE E5/0AS510 FOR DETAILS.
6. LIGHTING: REFER TO ELECTRICAL DRAWINGS FOR GARAGE LIGHTING
LAYOUT.
7. POLE LIGHTING: LEVEL 7 POLE MOUNTED LIGHTS - REFER TO 4D/4SJ502
FOR POLE MOUNTING DETAIL AT COLUMN AND DETAILS 2D, 2E, & 3C/4SJ504
FOR PCC POLE SUPPORT FOR LIGHTS LOCATED IN GAPS BETWEEN STITCH
WALLS
8. BOLLARDS: REFER TO DETAILS 2F, 4F, & 5F/4SJ502 FOR BOLLARD
MOUNTING AT ELEVATED SLABS AND DETAILS 7&8/4SJ013 FOR BOLLARD
MOUNTING AT SOG
GENERAL FLOOR PLAN NOTES
NOTE: FIRE EXTINGUISHER CABINETS
HAVE BEEN REMOVED FROM EWP-04
2 ADDENDUM #2 JULY 29, 2011
4 ADDENDUM #4 AUGUST 5, 2011
10 BULLETIN 011D MAY 31, 2013
RFI-03259: Canopy Steel connection clarification.