About this file

This architectural drawing is a floor plan for Building 4, Level 7 parking level, located at the Southeast Louisiana Veterans Healthcare System in New Orleans. The document, dated June 29, 2011, shows a detailed schematic of the parking level with grid lines, stairs (STK-1 and STK-2), ramps, and elevation specifications at 170'-0". The drawing includes notes about lighting layouts, roof plans, and a warning that there is no direct connection from Parking Level 7 to the concourse. The document lists multiple consulting engineers and architectural firms involved in the project, including Schrenk & Peterson, Korda/Nemeth Engineering, and BR+A Consulting Engineers. The drawing has undergone multiple revisions, with addenda dated July 29, 2011, August 5, 2011, and a bulletin from May 31, 2013.

View the file

Other files

File Type Posted
0211-4AS102-K.pdf PDF
NOVA VOLUME 2-Low Voltage_2013_0930.pdf PDF
NOVA VOLUME 2-Fire Protection_2013_0930.pdf PDF
629-25-100 Phase 1 RFI Register 05212025.docx DOCX document
0238-5AS102-L.pdf PDF
0240-5AS104-L.pdf PDF
NOVA VOLUME 2-Security_2013_0930.pdf PDF
NOVA VOLUME 2-Plumbing Tanks_2013_0930.pdf PDF
NOVA VOLUME 2-Plumbing_2013_0930.pdf PDF
NOVA VOLUME 2-Mechanical_2013_0930.pdf PDF
0243-5AS107-L.pdf PDF
0210-4AS101-K.pdf PDF
NOVA VOLUME 1_2013_0930.pdf PDF
NOVA VOLUME 2-Electrical_2013_0930.pdf PDF
0237-5AS101-L.pdf PDF
36C25625R0084 0001.docx DOCX document
0213-4AS104-K.pdf PDF
36C25625R0084 VA Patient Garage Report .pdf PDF
36C25625R0084 EXHIBIT F.docx DOCX document
36C25625R0084 01 00 00 General Requirements 03272025 .docx DOCX document
36C25625R0084 EXHIBIT C.docx DOCX document
36C25625R0084 RFP.docx DOCX document
36C25625R0084 EXHIBIT B.docx DOCX document
36C25625R0084 EXHIBIT A.docx DOCX document
36C25625R0084 01 35 26 Safety Requirements 03262025 .docx DOCX document
36C25625R0084 EXHIBIT E.docx DOCX document
36C25625R0084 EXHIBIT D.docx DOCX document
36C25625R0084 VA Staff Garage Report .pdf PDF
36C25625R0084.docx DOCX document
36C25625R0084 629-25-100 SOW 03262025 .docx DOCX document
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

DNDN

PARKING

LEVEL 7

ELEV = 170'-0"

STAIR

STK-1

STAIR

STK-2

5" EJ

4AS107K

4AI412

4AI403

F3

4AI402

F3

N

M

L

K

J

H

G

F

E

D

C

SEE DWG 3/4AS108-K

FOR ENLARGED ROOF

PLAN OVER STAIR #1

SEE DWG 4/4AS108-K

FOR ENLARGED ROOF

PLAN OVER STAIR #2

STP

STP04

1.4

3.6

0AS510

C3

RAMP

SEE DET C3 ON DWG

0A5201 FOR TYP LIGHTING

LAYOUT ON STAIR

WALLS THIS LEVEL

SEE DET C3 ON DWG

0A5201 FOR TYP LIGHTING

LAYOUT ON STAIR

WALLS THIS LEVEL

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

T E

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F I N

C H

O

N E

FO

O

T

TH

R

EE

Q U

A R

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

( 1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

E S

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

4AS107-K

BLDG 4 OVERALL SEVENTH PARKING LEVEL

DV MAGJUNE 30, 2011

CONSTRUCTION DOCUMENTS 1

629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MAINTENANCE

EWP_04

NO DIRECT CONNECTION FROM

PARKING LEVEL 7 TO CONCOURSE

SCALE: 1/16" = 1'-0"1 BLDG 4 LEVEL 7

1. GENERAL PARTITION TYPES: REFER TO SHEET 0AS002 FOR PARTITION

SCHEDULE AND GENERAL PARTITION TYPE NOTES.

2. ENLARGED PLANS: REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN

VIEWS INCLUDING MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.

3. RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH POCHE DENOTING

HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO

PARTITION TAGS ON FLOOR PLANS AND PARITION SCHEDULE SHEET 0AS002

FOR MORE INFORMATION.

4. DIMENSIONS: UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISH

FACE.

5. PIPE GUARDS: PROVIDE PIPE GUARDS AT ALL PIPE AND CONDUIT

EXPOSED TVEHICULAR TRAFFIC. SEE E5/0AS510 FOR DETAILS.

6. LIGHTING: REFER TO ELECTRICAL DRAWINGS FOR GARAGE LIGHTING

LAYOUT.

7. POLE LIGHTING: LEVEL 7 POLE MOUNTED LIGHTS - REFER TO 4D/4SJ502

FOR POLE MOUNTING DETAIL AT COLUMN AND DETAILS 2D, 2E, & 3C/4SJ504

FOR PCC POLE SUPPORT FOR LIGHTS LOCATED IN GAPS BETWEEN STITCH

WALLS

8. BOLLARDS: REFER TO DETAILS 2F, 4F, & 5F/4SJ502 FOR BOLLARD

MOUNTING AT ELEVATED SLABS AND DETAILS 7&8/4SJ013 FOR BOLLARD

MOUNTING AT SOG

GENERAL FLOOR PLAN NOTES

NOTE: FIRE EXTINGUISHER CABINETS

HAVE BEEN REMOVED FROM EWP-04

2 ADDENDUM #2 JULY 29, 2011

4 ADDENDUM #4 AUGUST 5, 2011

10 BULLETIN 011D MAY 31, 2013

CR

RFI 07592

RFI 07821

File details come from the government source that posted it. Updated .