S06 - Amendment 0006 2of2 (1).pdf

PDF 5 MB Posted

Attached to
Z2DA--695-22-117 CN New Audiology Clinic 5BN
Solicitation number
36C25225B0024
Issued by

About this file

This is a Pre-Renovation Hazardous Materials Survey report for the Department of Veteran's Affairs Milwaukee Medical Center, specifically for the Renovate 111 Audiology 5BN project located at 5000 W National Avenue in Milwaukee, Wisconsin. The comprehensive survey, conducted by Arc Environmental from March 2023 to February 2024, identified multiple hazardous materials requiring remediation, including asbestos-containing materials (ACMs) and lead-based paint. Key findings include approximately 143 asbestos-containing mudded pipe fittings, 1,908 square feet of asbestos-containing mastic beneath resilient sheet goods, 10 labeled fire doors with assumed asbestos, and lead-based paint on ceramic wall tiles in Room 5435 and a metal door jamb in Room 5425. The survey recommends proper abatement, handling, and disposal of these materials in accordance with EPA, OSHA, and Wisconsin Department of Health Services regulations before proceeding with the renovation project.

View the file

Other files

File Type Posted
36C25225B0024 0009.docx DOCX document
36C25225B0024 0008.docx DOCX document
S06 - Response 12.31.25 Pre-Bid RFIs_695-22-117_1.14.26 RFI 154.xlsx XLSX spreadsheet
S06 - Response 12.31.25 Pre-Bid RFIs_695-22-117_1.12.26 RFIs 152_153.xlsx XLSX spreadsheet
36C25225B0024 0007.docx DOCX document
S06 - Wage Determination 0006.txt TXT text file
S06 - Response 12.31.25 Pre-Bid RFIs_695-22-117_12.9.25 RFIs 1 -151.pdf PDF
0006 Narrative.pdf PDF
S06 - 36C25225B0024 0006.pdf PDF
S06 - Amendment 0006 1of2.pdf PDF
36C25225B0024 0005.docx DOCX document
36C25225B0024 0004.docx DOCX document
S06 - 36C25225B0024 0003.pdf PDF
S06 - Pre-bid Site Visit 30 attended 20251120.pdf PDF
S06 Spec section 00 01 15 list of Drawings sheets pp 123 w notes.pdf PDF
S06 - P000 - PLUMBING COVERSHEET.pdf PDF
S06 - 6c-695-22-117-Drawings Vol 1 General_Site_AESOC_Code_HazMat_13_pages 02.pdf PDF
S06 - 6a -695-22-117 VAMKE Audiology_100pc CD_Vol One Specifications Div 00-14.pdf PDF
S06 - 695_22_117 Drawing Sheet AI406 reissuse 13 Nov 2025.pdf PDF
Copy of S06 - Pre-Bid RFIs_695-22-117_11.18.25.xlsx XLSX spreadsheet
36C25225B0024 0002.docx DOCX document
36C25225B0024 0001.docx DOCX document
S02 -695-22-117 VAMKE Audiology - 100pc CD - Vol One Specifications Div 00-14.pdf PDF
S02 - 695-22-117 Drawings Vol 2_ FireProtection Sheets 6.pdf PDF
S02 - 695-22-117 Drawings Vol 2 Mechanical Sheets 17.pdf PDF
S02 - 695-22-117_Drawings Vol 1_Architectural Plans Sheets16.pdf PDF
S02 - 695-22-117 Fire Alarm System Single Source Justification_Executed.pdf PDF
36C25225B0024_1.docx DOCX document
S02 - 695-22-117 VAMKE Audiology - 100pc CD - Vol Two Specifications Div 21-28.pdf PDF
S02 - 695-22-117 Drawings Vol 1_Architectural_Sec_Details_WallTypes Sheets 8.pdf PDF
S02- 695-22-117 Door Hardware Single Source Justification_Executed.pdf PDF
ATTACHMENT 1_VAAR 852.219-75 JAN2023_REQUIRED TO COMPLETE.pdf PDF
S02 - Wage Determination WI 20250905.pdf PDF
S02 - 695-22-117 Vol 2 Drawings Electrical Low Voltage Sheets 14.pdf PDF
S02 - 695-22-117 Drawings_ Vol 2 Plumbing_Med Gas_Pneumatic Tube Sheets 11.pdf PDF
S02 - 695-22-117 Drawings Vol 1 Furniture_7 sheets.pdf PDF
S02 - 695-22-117 Drawings Vol 1 Equip_Sound Booths_Interiors_Signage Sheets 12 02.pdf PDF
S02 - MAP of East Entry for Site Visit 10.16.2025.pdf PDF
S02 - 695-22-117 Bldg Automation n HVAC Cntrl System Single Source Justification_Executed.pdf PDF
S02 - 695-22-117 Sole Source Justification_Nurse Call_Executed.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Limited sections included

These sections included

Pre-renovation Hazardous Material Survey

Clement J. Zablocki Veterans Administration Medical Center – Renovate 111 Audiology 5BN

Milwaukee, WI

Alliance Consulting Group Seven Generations AE JV, LLC 600 E Michigan Avenue, Suite B Kalamazoo, MI 49007

April 21, 2023 Updated February 21, 2024

Pre-renovation Hazardous Materials Survey Clement J. Zablocki VA Medical Center Renovate 111 Audiology 5BN April 21, 2023; Updated February 21, 2024 i

EXECUTIVE SUMMARY

Arc Environmental, LLC performed a pre-renovation hazardous material survey at the Clement J.

Zablocki Veterans Administration (VA) Medical Center in support of the Renovate 111 Audiology 5BN project. The survey was performed within the 5th Floor, B-wing (north) (5BN) and adjoining common areas; 3rd Floor Recreation Hall (which is vaulted through the 4th Floor); and Rooms 4422, 4428 and 4431 of Building 111 to assess building materials which may be impacted by planned construction activities for asbestos and lead-based paint; a visual inventory of existing equipment was performed to assess the project space of possible universal or other potentially regulated wastes. The survey was non-destructive and was not performed in a manner which provided full access to interstitial cavities. The pre-alteration survey was conducted on March 14, 2023. Supplemental surveys were performed on June 1, 2023, to evaluate dismantled wall-mounted units on the 7th Floor for the presence of asbestos-containing materials and February 1, 2024, to evaluate areas on the 4th, 3rd, and 5th Floors (as aforementioned) which may be impacted by mechanical work associated with the project.

During the survey, a total of 116 bulk samples were collected from 57 suspect homogenous areas identified throughout the Site; the 116 collected samples were split into 151 discrete layers for analysis.

Based on the findings of the asbestos survey, 12 of the sampled homogeneous materials were confirmed by laboratory analysis to be asbestos-containing materials. The confirmed asbestos-containing materials include the following:

• mudded pipe fittings;

• corrugated paper pipe insulation;

• black floor tile mastic associated with 12” x 12” brown floor tile

• black floor tile mastic associated with 12” x 12” tan floor tiles

• black/tan flooring mastic associated with off-white resilient sheet goods

• black flooring mastic associated with tan resilient sheet goods;

• 9” x 9” tan floor tiles;

• wall filler atop Concrete Masonry Unit (CMU) block walls;

• black floor tile mastic associated with 12” x 12” beige floor tiles;

• brown floor tile mastic associated with blue floor tiles;

• black pipe insulation within wall-mounted radiator units; and

• black panel mastic within wall-mounted radiator units.

Additionally, labeled fire doors were observed to be present within the project area and are assumed to contain asbestos-containing insulating cores. Section 2.0 provides additional details regarding the findings of the asbestos survey.

The lead-based paint screening was conducted at the Site using a portable X-ray Fluorescence (XRF) device. On-site testing revealed the presence of lead-based paint or coatings on limited surfaces within the project area. Components identified with lead-based paint include the ceramic wall tiles in Room 5435 and metal door jam in Room. Section 3.0 provides detail regarding the LBP survey.

i

Visual inspections were performed to identify additional, potential environmental concerns associated with the Site. Observed, potentially regulated and/or Universal wastes inventoried include assumed mercury-containing light bulbs, light ballasts with potential polychlorinated biphenyls or other regulated dielectric fluids, and emergency communication equipment assumed to contain batteries. Section 4.0 details the locations of the identified Universal and potentially regulated wastes.

Reviewed by:

Stacy Kahatapitiya Director of Industrial Hygiene Services

Table of Contents

1.0 Introduction

2.0 Asbestos-containing Materials Survey

2.1 Methodology

2.2 Findings and Recommendations

3.0 Lead-based Paint Survey

3.1 Methodology

3.2 Findings and Recommendations

4.0 Universal Wastes

4.1 Mercury

4.2 Polychlorinated Biphenyls

4.3 Other Potentially Regulated & Hazardous Wastes…………...………………………….…………5

Appendix A Asbestos Bulk Sampling Results Appendix B Summary of Materials Tested for Asbestos Appendix C Lead-based Paint Data Sheets Appendix D Photographic Log

April 21, 2023; Updated February 2024

1.0 Introduction

Arc Environmental, LLC performed a pre-renovation hazardous material survey at the Clement J.

Zablocki Veterans Administration (VA) Medical Center in support of the Renovate 111 Audiology 5BN project. The survey was performed within the 5th Floor, B-wing (north) (5BN) and adjoining common areas; 3rd Floor Recreation Hall (which is vaulted through the 4th Floor); and Rooms 4422, 4428 and 4431 of Building 111 to assess building materials which may be impacted by planned construction activities.

The survey included the assessment and sampling of suspect asbestos-containing materials (ACMs), lead-based paint (LBP), and inventorying other potential environmental conditions of concern. The survey did not include destructive survey methods; the findings of the survey are presented in this report. The pre-alteration survey was conducted on March 14, 2023. Supplemental surveys were performed on June 1, 2023, to evaluate dismantled wall-mounted units on adjacent floors for the presence of asbestos-containing materials and February 1, 2024, to evaluate areas on the 4th, 3rd, and 5th Floors (as aforementioned) which may be impacted by mechanical work associated with the project.

2.0 Asbestos-containing Materials Survey

2.1 Methodology

The asbestos survey included the identification, assessment, and sampling of suspect asbestos-containing materials and was performed by Ms. Stacy Kahatapitiya, an asbestos inspector trained in accordance with the U.S. Environmental Protection Agency (EPA) Model Accreditation Program (MAP). The survey was conducted under protocols established by the 40 Code of Federal Regulations (CFR) 763 Asbestos Hazard Emergency Response Act (AHERA) and 40 CFR 61 Subpart M, National Emission Standards for Hazardous Air Pollutants (NESHAP), as feasible. No access was provided above the metal ceiling tiles within hallway C5B08. Ceiling plenums within Rooms 5446 and 5442 could not be assessed due to the hard ceilings in these spaces. The survey included interior areas of the identified project space only.

Every reasonable attempt was made to locate suspect asbestos-containing materials (ACMs) present as thermal system insulation (TSI), surfacing material, or other miscellaneous materials. Specifically, Arc Environmental employed the following protocols while performing the survey: flooring materials were penetrated to the subfloor to determine how many layers of flooring were present; wall systems and ceiling systems were evaluated to identify suspect building materials associated with the systems themselves, as well as any accessible cavities; and mechanical insulation systems were evaluated to identify potential suspect insulation beneath jackets and wraps. Labeled fire doors were not physically sampled unless the insulating core was already exposed; all labeled fire doors observed within the project area which were not sampled (in an effort to maintain the integrity of the doors) are presumed to be ACMs.

During the survey, a total of 116 bulk samples were collected from 57 suspect homogenous areas identified throughout the accessible portions of the project area. The bulk samples of suspect ACMs were submitted, along with the corresponding chain-of-custody forms, to EMSL Analytical for analysis. EMSL is accredited for asbestos analysis in bulk materials through the National Voluntary Laboratory Accreditation Program (NVLAP).

The bulk samples were analyzed using polarized light microscopy (PLM/Dispersion Staining following the EPA method 600/R-93/116, Method for the Determination of Asbestos in Bulk Building Materials).

Based on the United States Environmental Protection Agency's (EPA’s) definition, a material which contains greater than one percent (1%) asbestos, as determined using the methods specified in Appendix E, Subpart E, 40 CFR Part 763, Section 1, Polarized Light Microscopy (PLM), is considered an ACM and must be handled according to OSHA, EPA, and Wisconsin Department of Health Services (DHS) regulations.

The findings and quantities of verified ACM are summarized in Table 1, Identified Asbestos-containing Materials. A copy of the chain of custody forms and Laboratory Analytical Results are included in Appendix A.

2.2 Findings and Recommendations

Table 1 below lists the confirmed ACMs identified at the Site. A complete list of the building materials sampled during this survey is presented in Appendix B. It is recommended that if additional suspect materials not identified in this report are uncovered/exposed during demolition or construction activities, the materials should be assumed to contain asbestos or sampled and analyzed for asbestos content to determine if they are ACMs.

Table 1: Identified Asbestos-containing Materials

HA Description Location Total Quantity

MJ1 Mudded Pipe Fitting

On valves, joints, and connections above ceilings and within accessible chases throughout 5th Floor areas and within ceiling cavity of 3rd Floor Recreation Hall (Room 3435)

188* EA

FM4 Black Mastic associated with

VT4

Beneath 12” x 12” tan floor tile with black specks in Room 5435 280 SF

FM5 Black/Tan Mastic associated with RS1

Beneath off-white resilient sheet goods in Rooms 5450, 5441, 5452, 5446, 5440, and 5438 1,908 SF

FM6 Black Mastic associated with

RS2

Beneath tan resilient sheet goods in Rooms 5437 and 5439 214 SF

FT5 9” x 9” Tan Floor Tile Beneath cabinetry units in Room 5450 180 SF

FM11 Black Mastic associated with FT8 Room 5423E 100 SF

FM9 Brown Mastic associated with FT6 Beneath 12” x 12” beige floor tile in Room 5446 5 SF

FM10 Brown Floor Tile Mastic associated with FT7

Beneath blue floor tiles below carpet in Rooms 5432, 5432A, 5432B, 5432C, and 5432D 652 SF

BI1 Block filler Applied to CMU block walls in closet 5B08 100 SF

PI1 Black Pipe Insulation Within wall-mounted radiator units on the 7th Floor; presumed to be present in units within

Rooms 5423B, 5423C, 5432D, and 5436

6* LF

PI2 Corrugated Paper Pipe Insulation

Within chase wall in Hallway C5808 opposite Room 5414 16* LF

Table 1: Identified Asbestos-containing Materials

HA Description Location Total Quantity

MA1 Black Panel Mastic Within wall-mounted radiator units on the 7th Floor; presumed to be present in units within

Rooms 5423B, 5423C, 5432D, and 5436

68 SF

FD1^ Labeled Fire Doors Rooms 5425, 5435, 5441, 5444, 5442, 5440, 5438, 5436, 5423, and Stair 6 10 EA

*Additional quantities may be present within inaccessible interstitial spaces.

^Labeled fire doors are assumed to contain asbestos insulating cores.

Note: Mudded fittings and corrugated paper pipe insulation located outside of the designated project area are not intended to be disturbed as part of this project. There are approximately 143 mudded fittings located within the main project area; no visible corrugated pipe insulation was found observed within the project area but is anticipated to be present in wall cavities where plumbing lines are present.

Regulated asbestos-containing materials (RACMs) identified at the Site include mudded pipe fittings, corrugated paper pipe insulation, and spray-applied block filler. The EPA, Occupational Safety and Health Administration (OSHA), and the Wisconsin DHS regulate friable asbestos-containing materials.

All friable asbestos-containing materials must be removed by a licensed asbestos abatement contractor and disposed of as a regulated waste prior to demolition activities that will result in the disturbance of these materials. The observed mudded pipe fittings were noted to be in good condition and labeled as ACM in several locations.

The various floor coverings and associated mastics are Category I non-friable materials (resilient floor coverings, asphalt roof products, gaskets, and packings). Category I non-friable materials may become friable if subjected to sanding, grinding, cutting, or abrading. The Category I Non-friable ACMs should be removed prior to disturbance if the materials may be rendered friable by construction activities. All abatement actions should be performed by personnel trained in accordance with EPA, OSHA, and Wisconsin DHS requirements for asbestos-related activities.

The labeled fire doors and radiator panel mastics are considered a Category II non-friable material.

Category II non-friable materials are regulated if they have a high probability of becoming or have become crumbled, pulverized, or reduced to powder by the forces expected to impact the materials during the course of demolition activities. These materials must be removed by a licensed asbestos abatement contractor prior to disturbance.

In addition, if other suspect materials are encountered during demolition that may be impacted, these materials should be sampled and analyzed by PLM to verify asbestos content, or be assumed as ACM, prior to disturbance. A complete list of the suspect materials sampled during this survey is presented in Appendix A.

3.0 Lead-based Paint Survey

3.1 Methodology

Painted surfaces within the project area were visually inspected to determine their condition. A lead screening survey was conducted using an X-ray Fluorescence (XRF) Spectrum Analyzer on painted building surfaces and/or components. Surfaces that are intact or deteriorated condition (as defined by the U.S. Department of Housing and Urban Development Guidelines) do not pose an immediate health risk, regardless of the lead content. Leaded paint in poor condition is a priority lead-hazard and should be promptly addressed using approved Lead Safe Work Practices.

The screening included field readings in addition to periodic calibration checks to ensure that the instrument is within acceptable calibration parameters. Lead-based paint, when tested via XRF, is defined by the U.S. Department of Housing and Urban Development (HUD) as paint having lead concentrations equal to or in excess of 1.0 milligrams per square centimeter (mg/cm²). The results of the lead-based paint survey are summarized in the XRF Lead-based Paint Inspection Data Sheets included in Appendix C.

3.2 Findings and Recommendations

Of the 233 of the field screening shots, two (2) yielded lead concentration above the State of Wisconsin threshold of (>1.0 mg/cm2) for lead-based paint. The lead-based coating was detected on ceramic wall tiles in Room 5435 and the metal door jamb in Room 5425.

The lead screening does not include testing of every painted surface within the project area; rather its intention is to characterize groups of similar components and coatings. If similar components with the same substrate and paint to those identified below are encountered during renovation activities, they are to be treated as lead-based paint affected. The intended use of the structure has not been determined as of the drafting of this report; lead abatement and/or lead safe work practices may be required as part of the construction project.

A lead Toxicity Characteristic Leaching Procedure (TCLP) test should be conducted for the demolition debris generated on Site. A representative waste stream sample should be collected to characterize the demolition debris, in accordance with the Resource Conservation and Recovery Act (RCRA), to determine disposal options. The hazardous waste criteria for lead waste is established under RCRA, Subtitle C, as 5.0 milligrams per liter (mg/L) measured with the TCLP as listed in CFR 40 Part 261. The lead-containing and lead-based paint debris generated during demolition should be handled in accordance with all applicable Federal and Wisconsin regulations.

4.0 Universal Wastes

Arc Environmental conducted a visual inspection for Universal Wastes (UWs) and other potentially regulated and hazardous wastes within the project area. As per 40 Code of Federal Regulations (CFR) 261 Subpart C, UWs include any of the following six wastes that have at least one hazardous characteristic: batteries, pesticides, thermostats, cathode ray tubes, mercury-containing devices, and mercury-containing lamps (e.g., fluorescent tubes and high intensity discharge lamps). These wastes require proper handling and disposal methods when no longer in use or prior to completing any planned renovation/demolition activities. All identified Universal and potentially regulated wastes must be handled, transported, and disposed of in accordance with applicable regulations prior to the renovation of the Site.

4.1 Mercury

Arc Environmental observed approximately 168 light tubes within the project area. Fluorescent tubes are assumed to contain mercury vapor; light-emitting diode (LED) lamps do not contain mercury vapor.

Mercury-containing fluorescent tubes will require proper removal and disposal in accordance with USEPA regulations listed in 40 CFR Part 273.

4.2 Polychlorinated Biphenyls

Arc Environmental conducted a visual inspection for PCB-containing light ballasts within fluorescent fixtures along with other potential PCB-containing equipment and material at the Site. All capacitors and fluorescent light ballasts that are not labeled as “non-PCB” should be assumed to contain PCBs.

Although the ballasts labeled as non-PCB-containing do not contain PCBs, they likely contain other regulated liquids. Arc Environmental recommends collecting and separating all fluorescent light ballasts by type during the demolition process. The ballasts should then be characterized for disposal in accordance with federal, state and local regulations.

4.3 Other Potentially Regulated and Hazardous Wastes

If other potentially regulated wastes such as fire extinguishers, batteries, and refrigerants are encountered during any renovation or demolition activities they will need to be removed and disposed in accordance with applicable Federal and state regulations to minimize the potential for release incidences which could result in environmental impacts.

Appendix A

Asbestos Bulk Sampling Results

NAN Technologies Inc., Environmental and Industrial Hygiene Services

1550 Caton Center Dr, Ste# M (Front), Halethorpe, MD - 21227 Lab ID# 600284-0

Client: Arc Environmental Date Reported: 03/27/23 Address: 1311 Haubert St Date Received: 03/16/23

Baltimore MD - 21230 Date Collected : 03/14/23 Analysis Date: 03/17-24/23

Attn: Stacey Kahatapitiya Sampler's Name: Stacey Kahatapitiya Phone: (443)864 - 7464 Project Name: MILWAUKEE VAMC - AUDIOLOGY E.Mail: skahatapitiya@arcenvironmental.com Project/Job ID: SEE COC

DKwon@arcenvironmental.com Sampling Site: SEE COC skim@arcenvironmental.com

NTEL File#: B23033160 - 3257

Asbestos Sample # Sample/ Material Description Appearance Type (%) % Fibrous % Nonfibrous

031423-5BN-B/1 Plaster-Skim White ND 4% Shredded Polymers 96% Binders

Homogeneous Perlite Carbonaceous

Plaster- Grey Grey ND 2% Shredded Polymers 98% Binders Quartz

Homogeneous Perlite Concrete Kind

031423-5BN-B/2 Drywall White / Brown ND 30% Cellulose 65% Binders

Homogeneous 5% Shredded Polymers Perlite Carbonaceous

031423-5BN-B/3 Joint Compound White ND 2% Shredded Polymers 98% Binders

Homogeneous Perlite Carbonaceous

031423-5BN-B/4 Gold Duct Seam Sealant Gold ND 3% Shredded Polymers 97% Binders

Homogeneous

031423-5BN-B/5 12''x12'' Off-White Floor Tile White ND 2% Shredded Polymers 96% Binders Quartz

Homogeneous 2% Cellulose Silicate

Associate Mastic Tan ND 2% Shredded Polymers 98% Binders

Homogeneous Quartz

031423-5BN-B/6 2'x4' Worm and Pinhole White / Brown ND 45% Shredded Polymers 50% Binders Perlite

Pattern Ceiling Tile Homogeneous 5% Cellulose Glass Beads Carbonaceous

031423-5BN-B/7 4" Beige Covebase Beige ND ND 100% Binders

Homogeneous

Associate Adhesive White ND ND 100% Binders

Homogeneous

031423-5BN-B/8 Cloth Pipe Insulation Wrap White / Brown ND 40% Ceramic Fibers 30% Binders

Homogeneous 30% Shredded Polymers Quartz

031423-5BN-B/9 Mudded Pipe Fitting White Chrysotile 10% 35% Shredded Polymers 55% Binders Quartz

Homogeneous Glass Beads

031423-5BN-B/10 12"x12" Off White Floor Tile White ND 2% Shredded Polymers 95% Binders Quartz

Homogeneous 3% Cellulose Silicate

Associate Mastic Grey ND ND 100% Binders

Homogeneous Quartz

NOTICE/DISCLAMER: NAN Technologies Inc Environmental Testing Lab (NTEL), Perform the testing and analyses on samples upon submission of information and material supplied by client(s). NTEL does NOT express opinion / interpretation on data or results. Report(s) made for clients exclusive and confidential use only. No person or entity other than client does not use/relay any such report. Any such reliance will be unjustified and if does so at his or her own risk. Any report provided by NTEL shall not be reproduced, in whole or in part, without the written approval of NTEL. In no event shall NTEL be responsible for any damage greater than the amount that it received for performing some or all of the testing and analyses listed above.

PLM Report by EPA/600/R-93/116 and App. E to Sub. E of 40 CFR Part 763 .

Non- Asbestos Composition

Ph# (410) 800 - 4263, www.nantechnologiesinc.com.

1550 Caton Center Dr, Ste# M (Front), Halethorpe, MD - 21227 Lab ID# 600284-0

Asbestos Sample # Sample/ Material Description Appearance Type (%) % Fibrous % Nonfibrous 031423-5BN-B/11 2'X2' Smooth Ceiling Tile White / Brown ND 45% Shredded Polymers 45% Binders Quartz

Homogeneous 10% Cellulose Glass Beads

031423-5BN-B/12 12"x12" Beige Floor Tile White ND 2% Cellulose 98% Binders Quartz

Homogeneous Silicate

Associate Mastic Green ND 4% Shredded Polymers 96% Binders

Homogeneous Quartz

031423-5BN-B/13 Joint Compound White ND 2% Shredded Polymers 98% Binders Perlite

Homogeneous Carbonaceous Paint

031423-5BN-B/14 Red Fire Stop Red ND 15% Polymers 85% Binders Quartz

Homogeneous Perlite

031423-5BN-B/15 Red Fire Stop Red ND 20% Polymers 80% Binders Quartz

Homogeneous Perlite

031423-5BN-B/16 4" Black Covebase Black ND ND 100% Binders

Homogeneous

Associated White Adhesive White ND ND 100% Binders

Homogeneous Quartz

031423-5BN-B/17 Tan Ceramic Tile Glue Yellow ND 25% Polymers 70% Binders

Homogeneous 5% Glass Fibers Glass Beads

031423-5BN-B/18 Foil Backed Paper Pipe Black / Yellow ND 60% Ceramic Fibers 30% Binders

Insulation with Black Tar Homogeneous 10% Glass Fibers Silver Foil

031423-5BN-B/19 Ceramic Tile Grout Bed White ND ND 100% Binders

Homogeneous

Glue Tan ND 25% Polymers 70% Binders Perlite

Homogeneous 5% Glass Beads Quartz

031423-5BN-B/20 Grey Fire Door Panel Grey ND ND 100% Binders

Glazing Homogeneous Perlite

031423-5BN-B/21 Grey Fire Door Grey ND ND 100% Binders

Panel Glazing Homogeneous Perlite

031423-5BN-B/22 4" Black Covebase Black ND ND 100% Binders

Homogeneous

Associated White Adhesive White ND ND 100% Binders

Homogeneous

031423-5BN-B/23 Plaster Skim White ND 2% Shredded Polymers 98% Binders Perlite

Homogeneous Carbonaceous Paint

Plaster Base White / Grey ND 2% Shredded Polymers 98% Binders Quartz

Homogeneous Perlite Carbonaceous

031423-5BN-B/24 12''X12" Tan FT W/Faux Tan/Brown ND 2% Shredded Polymers 98% Binders Quartz

Geode Pattern Homogeneous Silicate

NOTICE/DISCLAMER: NAN Technologies Inc Environmental Testing Lab (NTEL), Perform the testing and analyses on samples upon submission of information and material supplied by client(s). NTEL does NOT express opinion / interpretation on data or results. Report(s) made for clients exclusive and confidential use only. No person or entity other than client does not use/relay any such report. Any such reliance will be unjustified and if does so at his or her own risk. Any report provided by NTEL shall not be reproduced, in whole or in part, without the written approval of NTEL. In no event shall NTEL be responsible for any damage greater than the amount that it received for performing some or all of the testing and analyses listed above.

Non- Asbestos Composition

1550 Caton Center Dr, Ste# M (Front), Halethorpe, MD - 21227 Lab ID# 600284-0

Asbestos Sample # Sample/ Material Description Appearance Type (%) % Fibrous % Nonfibrous 031423-5BN-B/24 Associate Mastic Tan ND 3% Shredded Polymers 97% Binders

Homogeneous Quartz

031423-5BN-B/25 Plaster Skim White ND 2% Shredded Polymers 98% Binders Perlite

Homogeneous Carbonaceous Paint

Plaster Base White / Grey ND 2% Shredded Polymers 98% Binders Quartz

Homogeneous Perlite Carbonaceous

031423-5BN-B/26 12"x12" Tan Floor Tile Tan ND 3% Shredded Polymers 97% Binders Quartz

With Black Specks Homogeneous Silicate

Associate Mastic Black 6% Chrysotile ND 94% Binders

Homogeneous Quartz

031423-5BN-B/27 4" Tan Covebase Tan ND 2% Cellulose 98% Binders

Homogeneous

Associated Beige Adhesive Beige ND 4% Shredded Polymers 96% Binders

Homogeneous Perlite

031423-5BN-B/28 2'x2' Textured Ceiling Tile White / Brown ND 35% Shredded Polymers 60% Binders

Homogeneous 5% Cellulose Perlite

031423-5BN-B/29 Joint Compound White ND 10% Polymers 70%Binders Paint

Homogeneous 20% Cellulose Perlite Carbonaceous

031423-5BN-B/30 Drywall White / Brown ND 3% Polymers 60% Binders

Homogeneous Perlite Carbonaceous

031423-5BN-B/31 Plaster-Skim White ND 3% Shredded Polymers 97% Binders

Homogeneous Concrete Kind

Plaster-Base White / Grey ND 2% Shredded Polymers 60% Binders

Homogeneous Perlite Carbonaceous

031423-5BN-B/32 Tan Ceramic Tile Glue Tan ND ND 100% Binders Quartz

Homogeneous

031423-5BN-B/33 2'x2' Textured Ceiling Tile White/Brown ND 40% Shredded Polymers 55% Binders Quartz

Homogeneous 5%Cellulose Corbonaceous

031423-5BN-B/34 12"x12" Tan FT w/Black Specks Tan ND 3% Cellulose 97% Binders Quartz

Homogeneous Silicate

Associated Mastic Black/Grey ND 2% Shredded Polymers 98% Binders

Homogeneous Quartz

Gray Leveling Compound Black/Grey ND 5% Cellulose 95% Binders

Homogeneous

031423-5BN-B/35 2'X4" Divot Pattern CT White/Brown ND 35% Shredded Polymers 60% Binders Quartz

Homogeneous 5%Cellulose Corbonaceous

031423-5BN-B/36 2'X4" Deep Fissure Pattern CT White/Brown ND 25% Shredded Polymers 70% Binders Quartz Homogeneous 5%Glass Fibers Corbonaceous Perlite

031423-5BN-B/37 Off-white Duct Seam Sealant on White ND 35%Glass Fibers 40% Binders Quartz Foil backed Fiberglass Wrap Homogeneous 25% Polymers Silver Foil

NOTICE/DISCLAMER: NAN Technologies Inc Environmental Testing Lab (NTEL), Perform the testing and analyses on samples upon submission of information and material supplied by client(s). NTEL does NOT express opinion / interpretation on data or results. Report(s) made for clients exclusive and confidential use only. No person or entity other than client does not use/relay any such report. Any such reliance will be unjustified and if does so at his or her own risk. Any report provided by NTEL shall not be reproduced, in whole or in part, without the written approval of NTEL. In no event shall NTEL be responsible for any damage greater than the amount that it received for performing some or all of the testing and analyses listed above.

Non- Asbestos Composition

1550 Caton Center Dr, Ste# M (Front), Halethorpe, MD - 21227 Lab ID# 600284-0

Asbestos Sample # Sample/ Material Description Appearance Type (%) % Fibrous % Nonfibrous 031423-5BN-B/38 Cloth Pipe Insulation Wrap White/Brown ND 60%Ceramic Fibers 10% Binders

Homogeneous 30% Polymers Quartz

031423-5BN-B/39 Joint Compound White ND 5% Shredded Polymers 85% Binders Perlite

Homogeneous 10%Cellulose Corbonaceous

031423-5BN-B/40 Textured Spray-applied Finish White/Brown ND 20%Cellulose 70% Binders Quartz

Over Drywall Homogeneous 10% Polymers Perlite Carbonaceous

031423-5BN-B/41 Textured Spray-applied Finish White/Brown ND 25%Cellulose 60% Binders Quartz

Over Drywall Homogeneous 15% Polymers Perlite Carbonaceous

031423-5BN-B/42 Textured Spray-applied Finish White/Brown ND 25%Cellulose 65% Binders Quartz

Over Drywall Homogeneous 10% Polymers Perlite Carbonaceous

031423-5BN-B/43 Woven wall Covering w/ Tan ND 2% Shredded Polymers 98% Binders

Tan Adhesive Homogeneous

Associated adhesive Tan/Yellow ND 2% Shredded Polymers 98% Binders Perlite

Homogeneous Quartz

031423-5BN-B/44 Woven wall Covering w/ Tan ND 2% Shredded Polymers 98% Binders

Tan Adhesive Homogeneous

Associated adhesive Tan/Yellow ND 3% Shredded Polymers 97% Binders Perlite

Homogeneous Quartz

031423-5BN-B/45 White Fire Door Core Insulation White ND 2% Shredded Polymers 98% Binders

Homogeneous Vermiculate

031423-5BN-B/46 Off-white Resillent Sheetgoods Tan ND 2% Shredded Polymers 98% Binders Quartz w/Black and Tan Mastic Homogeneous Glass Beads

Associated Black/Tan Mastic Black/Tan Chrysotile5% ND 95% Binders

Homogeneous

031423-5BN-B/47 Brown Cove Base Mastic Brown ND 2% Shredded Polymers 98% Binders

Homogeneous Mastic

031423-5BN-B/48 Brown Cove Base Mastic Brown ND 3% Shredded Polymers 97% Binders

Homogeneous Mastic

031423-5BN-B/49 4" Brown Cove Base Brown ND 2% Shredded Polymers 98% Binders

Homogeneous Quartz

Associated Tan Adhesive Tan ND 3% Shredded Polymers 97% Binders Quartz

Homogeneous

031423-5BN-B/50 Tan Resillent Sheetgoods Tan ND 2% Shredded Polymers 98% Binders

Homogeneous

Associated Black Mastic Black Chrysotile4% 1% Shredded Polymers 95% Binders Quartz

Homogeneous Mastic

031423-5BN-B/51 4" Grey Cove Base Grey ND 2% Shredded Polymers 98% Binders

Homogeneous Perlite

Associated Tan Adhesive Tan ND 2% Shredded Polymers 98% Binders Homogeneous

NOTICE/DISCLAMER: NAN Technologies Inc Environmental Testing Lab (NTEL), Perform the testing and analyses on samples upon submission of information and material supplied by client(s). NTEL does NOT express opinion / interpretation on data or results. Report(s) made for clients exclusive and confidential use only. No person or entity other than client does not use/relay any such report. Any such reliance will be unjustified and if does so at his or her own risk. Any report provided by NTEL shall not be reproduced, in whole or in part, without the written approval of NTEL. In no event shall NTEL be responsible for any damage greater than the amount that it received for performing some or all of the testing and analyses listed above.

Non- Asbestos Composition

1550 Caton Center Dr, Ste# M (Front), Halethorpe, MD - 21227 Lab ID# 600284-0

Asbestos Sample # Sample/ Material Description Appearance Type (%) % Fibrous % Nonfibrous 031423-5BN-B/52 2'X4' Divot Pattern CT Grey ND 25% Polymers 60% Binders Glass Beads

Homogeneous 15%Cellulose Carbonaceous

031423-5BN-B/53 2'X2' Drywall CT White/Brown ND 5% Polymers 80% Binders Mica

Homogeneous 15%Cellulose Carbonaceous

031423-5BN-B/54 Off-white Duct Seam Sealant on Silver/Yellow ND 15% Polymers 85% Binders

Foil-Backed Fiberglass Wrap Homogeneous Silver Foil

031423-5BN-B/55 Tan Resillent Sheetgoods Tan ND ND 100% Binders w/Black Mastic Homogeneous

Associated Black/Tan Mastic Black Chrysotile10% 2% Polymers 88% Binders Mastic

Homogeneous

031423-5BN-B/56 Brown/Red Duct Seam Sealant Brown/Red ND ND 100% Binders

Homogeneous

031423-5BN-B/57 Brown/Red Duct Seam Sealant Brown/Red ND ND 100% Binders

Homogeneous

031423-5BN-B/58 Brown Duct Seam Sealant on Brown/Silver ND 35% Glass Fibers 60% Binders

Foil-Backed Fiberglass Wrap Homogeneous 5% Polymers Silver Foil

031423-5BN-B/59 Brown Seam Sealant on Brown/Yellow ND 40% Glass Fibers 60% Binders

Pipe Wrap Homogeneous

031423-5BN-B/60 Cloth Pipe Wrap Tan ND 80% Ceramic Fibers 20% Binders

Homogeneous

031423-5BN-B/61 6" Gray Covebase Gray ND ND 100% Binder w/Yellow Mastic Homogeneous Carbonaceous

Associated Yellow Mastic Yellow ND ND 100% Binders

Homogeneous Mastic

031423-5BN-B/62 Black Window Caulk Sample is not enough to Analyse

031423-5BN-B/63 2'x4' Worm and Pinhole Pattern CT Brown/Grey ND 10% Polymers 70% Binders Glass Beads

Homogeneous 20%Cellulose Mica Carbonaceous

031423-5BN-B/64 Mudded Pipe Fitting White Chrysotile8% 7% Glass Fibers 85% Binders

Homogeneous Glass Beads

031423-5BN-B/65 Blue Resilient Sheet Goods Blue ND ND 100% Binder w/ Tan Mastic Homogeneous Concrete Kind

Associated Tan Mastic Tan ND ND 100% Binders

Homogeneous Mastic

031423-5BN-B/66 Blue Resilient Sheet Goods Blue ND 2% Shredded Polymers 98% Binders Perlite w/ Tan Mastic Homogeneous

Associated Tan Mastic Tan ND 4% Shredded Polymers 96% Binders Quartz

Homogeneous

031423-5BN-B/67 Lab Counter Top Grey ND ND 100% Binders Homogeneous

NOTICE/DISCLAMER: NAN Technologies Inc Environmental Testing Lab (NTEL), Perform the testing and analyses on samples upon submission of information and material supplied by client(s). NTEL does NOT express opinion / interpretation on data or results. Report(s) made for clients exclusive and confidential use only. No person or entity other than client does not use/relay any such report. Any such reliance will be unjustified and if does so at his or her own risk. Any report provided by NTEL shall not be reproduced, in whole or in part, without the written approval of NTEL. In no event shall NTEL be responsible for any damage greater than the amount that it received for performing some or all of the testing and analyses listed above.

Non- Asbestos Composition

1550 Caton Center Dr, Ste# M (Front), Halethorpe, MD - 21227 Lab ID# 600284-0

Asbestos Sample # Sample/ Material Description Appearance Type (%) % Fibrous % Nonfibrous 031423-5BN-B/68 Lab Counter Top Sample is not enough to Analyse

031423-5BN-B/69 2'X2' Drywall CT White/Brown ND 15%Cellulose 85% Binders

Homogeneous Carbonaceous

031423-5BN-B/70 Tan Drywall Glue Tan ND 3% Shredded Polymers 97% Binders

Homogeneous Perlite

031423-5BN-B/71 Tan Drywall Glue Tan/White ND ND 100% Binders

Homogeneous

031423-5BN-B/72 9"x9" Tan Floor Tile Tan/Brown ND ND 100% Binders Silicate w/Black Mastic Homogeneous Tile

Associated Tan Mastic Tan ND ND 100% Binders

Homogeneous Mastic

031423-5BN-B/73 9"x9" Tan Floor Tile Tan Chrysotile2% 3% Cellulose 95% Binders Quartz w/Black Mastic Homogeneous Silicate Tile

Associated Black Mastic Black ND 3% Shredded Polymers 97% Binders Quartz

Homogeneous Mastic

031423-5BN-B/74 2'x4' Textured CT White ND 40% Shredded Polymers 55% Binders Quartz

Homogeneous 5% Glass Fibers Perlite Glass Beads

031423-5BN-B/75 Black Window Caulk Black ND ND 100% Binders

Homogeneous Mastic

031423-5BN-B/76 Off-white Sink Undercoating White ND ND 100% Binders

Homogeneous Perlite

031423-5BN-B/77 Offwhite Sink Undercoating White ND ND 100% Binders Quartz

Homogeneous Perlite

031423-5BN-B/78 Woven Wall Covering White ND ND 100% Binders

Homogeneous

031423-5BN-B/79 CMU Block Filler White ND ND 100% Binders

Homogeneous

031423-5BN-B/80 Green/Tan Window Glazing Sample is not enough to Analyse on Fire Door

031423-5BN-B/81 CMU Block Filler White/Gray Chrysotile8% 2% Shredded Polymers 90% Binders Quartz

Homogeneous

031423-5BN-B/82 12"x12" Beige Floor Tile Beige ND ND 100% Binders Tile w/Black Mastic Homogeneous Silicate

Associated Black Mastic Black ND ND 100% Binders Mastic

Homogeneous Mastic

031423-5BN-B/83 12"x12" Beige Floor Tile Beige ND 3% Shredded Polymers 97% Binders Quartz w/Black Mastic Homogeneous Silicate

Associated Black Mastic Black Chrysotile5% 3% Shredded Polymers 92% Binders Quartz Homogeneous

NOTICE/DISCLAMER: NAN Technologies Inc Environmental Testing Lab (NTEL), Perform the testing and analyses on samples upon submission of information and material supplied by client(s). NTEL does NOT express opinion / interpretation on data or results. Report(s) made for clients exclusive and confidential use only. No person or entity other than client does not use/relay any such report. Any such reliance will be unjustified and if does so at his or her own risk. Any report provided by NTEL shall not be reproduced, in whole or in part, without the written approval of NTEL. In no event shall NTEL be responsible for any damage greater than the amount that it received for performing some or all of the testing and analyses listed above.

Non- Asbestos Composition

1550 Caton Center Dr, Ste# M (Front), Halethorpe, MD - 21227 Lab ID# 600284-0

Asbestos Sample # Sample/ Material Description Appearance Type (%) % Fibrous % Nonfibrous 031423-5BN-B/84 4" Brown Covebase and Brown ND ND 100% Binders

Brown Adhesive Homogeneous

Associated Brown Adhesive Brown ND ND 100% Binders

Homogeneous Mastic

031423-5BN-B/85 4" Brown Covebase and Brown ND 3% Shredded Polymers 97% Binders Quartz

Brown Adhesive Homogeneous Perlite

Associated Brown Adhesive Brown ND 2% Shredded Polymers 98% Binders Perlite

Homogeneous

031423-5BN-B/86 Woven Wall Covering White/Yellow ND ND 100% Binders

Homogeneous

031423-5BN-B/87 Tan Carpet Mastic Tan ND ND 100% Binders

Homogeneous Mastic

031423-5BN-B/88 Grey Resilient Sheet Goods Grey ND ND 100% Binders

Homogeneous

031423-5BN-B/89 Black Duct Seam Sealent on Black/Silver ND 15% Shredded Polymers 50% Binders Quartz

Foil-Backed Fiberglass Wrap Homogeneous 35% Glass Fibers Silver Foil

031423-5BN-B/90 Black Duct Seam Sealent on Black ND 5% Polymers 95% Binders

Foil-Backed Fiberglass Wrap Homogeneous Silver Foil

031423-5BN-B/91 Blue Floor Tile and Brown Blue ND ND 100% Binders Silicate

Mastic Beneath Carpet Homogeneous Tile

Associated Brown Mastic Brown Chrysotile8% ND 92% Binders Mastic

Homogeneous

031423-5BN-B/92 Blue Floor Tile and Brown Blue ND 3% Shredded Polymers 97% Binders Quartz

Mastic Beneath Carpet Homogeneous Silicate

Associated Brown Mastic Brown Chrysotile5% ND 95% Binders Quartz

Homogeneous

031423-5BN-B/93 2'x4' Dot CT Brown/White ND 20% Shredded Polymers 65% Binders Quartz

Homogeneous 15%Cellulose Perlite Carbonaceous

031423-5BN-B/94 2'x4' Dot CT Brown/White ND 30% Shredded Polymers 50% Binders Quartz

Homogeneous 20%Cellulose Perlite Carbonaceous

031423-5BN-B/95 White Replacement Window White ND ND 100% Binders

Glazing Homogeneous Glazing

031423-5BN-B/96 2'x2' Smooth CT Brown/White ND 25% Shredded Polymers 55% Binders Quartz

Homogeneous 20%Cellulose Perlite Carbonaceous

NOTICE/DISCLAMER: NAN Technologies Inc Environmental Testing Lab (NTEL), Perform the testing and analyses on samples upon submission of information and material supplied by client(s). NTEL does NOT express opinion / interpretation on data or results. Report(s) made for clients exclusive and confidential use only. No person or entity other than client does not use/relay any such report. Any such reliance will be unjustified and if does so at his or her own risk. Any report provided by NTEL shall not be reproduced, in whole or in part, without the written approval of NTEL. In no event shall NTEL be responsible for any damage greater than the amount that it received for performing some or all of the testing and analyses listed above.

Non- Asbestos Composition

1550 Caton Center Dr, Ste# M (Front), Halethorpe, MD - 21227 Lab ID# 600284-0

Asbestos Sample # Sample/ Material Description Appearance Type (%) % Fibrous % Nonfibrous 031423-5BN-B/97 Grey Resilient Sheet Goods Grey ND ND 100% Binders

Homogeneous

031423-5BN-B/98 White Replacement Window White ND ND 100% Binders

Glazing Homogeneous

DW - Drywall, MS - Mastic, SOFP - Spray-on Fire Proofing, FT - Floor Tile, RF - Roofing materials, CT - Ceiling Tile, PC - Popcorn Ceiling, SU - Sink Underlayment, WP - Window Putty.

Samples were analyszed in compliance with appendix E of 40 CFR to subpart E part 763, EPA 600/M4-82020 ''interimmethod, but augmented with procedured outlined in the 1993 (final) version of the method.

Components of nonhomogeneous or multi layered samples analyzed seperately and report respective component and /or individual layer. NTEL bears no responsibility for sample collection and or analytical method limitations. Report of results relate only to the tested items.The above samples were collected by client and the conditions of the samples analyzed were acceptable upon reciept to lab unless otherwise noted in report.

Analyzed by Reviewed By

KS/RC NK

Approved Signature

NOTICE/DISCLAMER: NAN Technologies Inc Environmental Testing Lab (NTEL), Perform the testing and analyses on samples upon submission of information and material supplied by client(s). NTEL does NOT express opinion / interpretation on data or results. Report(s) made for clients exclusive and confidential use only. No person or entity other than client does not use/relay any such report. Any such reliance will be unjustified and if does so at his or her own risk. Any report provided by NTEL shall not be reproduced, in whole or in part, without the written approval of NTEL. In no event shall NTEL be responsible for any damage greater than the amount that it received for performing some or all of the testing and analyses listed above.

END OF REPORT

Non- Asbestos Composition

Note: ND- None Detected

1550 Caton Center Dr, Ste# M (Front), Halethorpe, MD - 21227 Lab ID# 600284-0

Client: Arc Environmental Date Reported: 06/09/23 Address: 1311 Haubert St Date Received: 06/08/23

Baltimore MD - 21230 Date Collected : SEE COC Analysis Date: 06/09/23

Attn: Stacey Kahatapitiya Sampler's Name: Stacey Kahatapitiya Phone: (443)864 - 7464 Project Name: MILWAUKE VA #5BN E.Mail: skahatapitiya@arcenvironmental.com Project/Job ID: SEE COC skim@arcenvironmental.com Sampling Site: BLDG 111

NTEL File#: B23061175 - 1181 Asbestos

Sample # Sample/ Material Description Appearance Type (%) % Fibrous % Nonfibrous 060123-5BN-B/1 Pipe Insulation Black Chrysotile7% ND 93% Binders

Homogeneous

060123-5BN-B/2 Panel Mastic Black Chrysotile10% ND 90% Binders Mica

Homogeneous Mastic

060123-5BN-B/3 Pipe Insulation Black ND 3%Polymers 97% Binders

Homogeneous

060123-5BN-B/4 Plaster - Skim White ND ND 100% Binders

Homogeneous Carbonaceous Paint

Plaster - Base Gray ND ND 100% Binders

Homogeneous Concrete Kind

060123-5BN-B/5 Plaster - Skim White ND ND 100% Binders

Homogeneous Carbonaceous Paint

Plaster - Base Gray ND ND 100% Binders

Homogeneous Concrete Kind

060123-5BN-B/6 Plaster - Skim White ND ND 100% Binders

Homogeneous Carbonaceous Paint

Plaster - Base Gray ND ND 100% Binders

Homogeneous Concrete Kind

060123-5BN-B/7 Panel Mastic Black ND ND 100% Binders Rubberkind

Homogeneous Mastic

DW - Drywall, MS - Mastic, SOFP - Spray-on Fire Proofing, FT - Floor Tile, RF - Roofing materials, CT - Ceiling Tile, PC - Popcorn Ceiling, SU - Sink Underlayment, WP - Window Putty.

Samples were analyszed in compliance with appendix E of 40 CFR to subpart E part 763, EPA 600/M4-82020 ''interimmethod, but augmented with procedured outlined in the 1993 (final) version of the method.

Components of nonhomogeneous or multi layered samples analyzed seperately and report respective component and /or individual layer. NTEL bears no responsibility for sample collection and or analytical method limitations. Report of results relate only to the tested items.The above samples were collected by client and the conditions of the samples analyzed were acceptable upon reciept to lab unless otherwise noted in report.

Analyzed by Reviewed By

KS NK

Approved Signature

NOTICE/DISCLAMER: NAN Technologies Inc Environmental Testing Lab (NTEL), Perform the testing and analyses on samples upon submission of information and material supplied by client(s). NTEL does NOT express opinion / interpretation on data or results. Report(s) made for clients exclusive and confidential use only. No person or entity other than client does not use/relay any such report. Any such reliance will be unjustified and if does so at his or her own risk. Any report provided by NTEL shall not be reproduced, in whole or in part, without the written approval of NTEL. In no event shall NTEL be responsible for any damage greater than the amount that it received for performing some or all of the testing and analyses listed above.

PLM Report by EPA/600/R-93/116 and App. E to Sub. E of 40 CFR Part 763 .

Non- Asbestos Composition

Note: ND- None Detected

END OF REPORT

EMSL Analytical, Inc.

10-39 45th Road Long Island City, NY 11101

Tel/Fax: (212) 290-0051 / (212) 290-0058 http://www.EMSL.com / manhattanlab@emsl.com

032401562EMSL Order:

ARCE78Customer ID:

Customer PO:

Project ID:

Attention: Phone:Stacy Kahatapitiya (443) 864-7464

Fax:Arc Environmental (410) 962-1065

Received Date:1311 Haubert Street 02/07/2024 10:40 AM

Analysis Date:Baltimore, MD 21230 02/09/2024 - 02/10/2024

Collected Date: 02/05/2024

Project: Milwaukee VAMC - Audiology/ WI

Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E

Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous % Type

Non-Asbestos Asbestos

5BN-B/98

032401562-0001

Off-white duct seam sealant

Brown

Non-Fibrous

Homogeneous

None DetectedCellulose

MinWool

Glass

10%

20%

5%

25%

40.0%

Ca Carbonate

Non-fibrous (Other)

5BN-B/99

032401562-0002

Paper pipe insulation with black mastic

Tan/Black/Silver

Non-Fibrous

Homogeneous

None DetectedCellulose

Glass

10%

35%

55.0% Non-fibrous (Other)

5BN-B/100

032401562-0003

Paper pipe insulation Brown

Non-Fibrous

Homogeneous

None DetectedCellulose

Glass

15%

20%

25%

40.0%

Gypsum

Non-fibrous (Other)

5BN-B/101

032401562-0004

Shocrete Tan/White

Non-Fibrous

Homogeneous

None Detected45%

35%

20.0%

Quartz

Ca Carbonate

Non-fibrous (Other)

5BN-B/102

032401562-0005

2'x2' ceiling tile Tan

Fibrous

Homogeneous

None DetectedCellulose

MinWool

Glass

40%

20%

10%

30.0% Non-fibrous (Other)

5BN-B/103

032401562-0006

Drywall with woven wallpaper

Tan/White

Non-Fibrous

Homogeneous

None DetectedCellulose30% 5%

35%

30.0%

Ca Carbonate

Gypsum

Non-fibrous (Other)

5BN-B/104-Floor

Tile

032401562-0007

12"x12" brown mottled floor tile with brown mastic

Brown

Non-Fibrous

Homogeneous

None DetectedCellulose3% 70%

17%

3%

7.0%

Ca Carbonate

Gypsum

Mica

Non-fibrous (Other)

5BN-B/104-Mastic

032401562-0007A

12"x12" brown mottled floor tile with brown mastic

Brown/Black

Non-Fibrous

Homogeneous

Chrysotile5%10%

85.0%

Ca Carbonate

Non-fibrous (Other)

5BN-B/105-Floor

Tile

032401562-0008

12"x12" brown mottled floor tile with brown mastic

Brown

Non-Fibrous

Homogeneous

None Detected45%

55.0%

Ca Carbonate

Non-fibrous (Other)

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA

600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.

Estimation of uncertainty is available on request.

Samples analyzed by EMSL Analytical, Inc. Long Island City, NY AIHA LAP, LLC-IHLAP Accredited #102581, NVLAP Lab Code 101048-9, CT PH-0170, MA AA000170

Initial report from: 02/10/2024 12:50:56

ASB_PLMwSigs_0007_0001 Printed:2/10/2024 12:50:57PM Page 1 of 3

Tel/Fax: (212) 290-0051 / (212) 290-0058 http://www.EMSL.com / manhattanlab@emsl.com

032401562EMSL Order:

ARCE78Customer ID:

Customer PO:

Project ID:

Attention: Phone:Stacy Kahatapitiya (443) 864-7464

Fax:Arc Environmental (410) 962-1065

Received Date:1311 Haubert Street 02/07/2024 10:40 AM

Analysis Date:Baltimore, MD 21230 02/09/2024 - 02/10/2024

Collected Date: 02/05/2024

Project: Milwaukee VAMC - Audiology/ WI

Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E

Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous % Type

Non-Asbestos Asbestos

5BN-B/105-Mastic

032401562-0008A

12"x12" brown mottled floor tile with brown mastic

Brown/Black

Non-Fibrous

Homogeneous

Chrysotile5%10%

85.0%

Ca Carbonate

Non-fibrous (Other)

5BN-B/106

032401562-0009

Cloth wrapped paper pipe insulation

Gray

Non-Fibrous

Homogeneous

Chrysotile20%Cellulose30% 50.0% Non-fibrous (Other)

5BN-B/107

032401562-0010

Cloth wrapped paper pipe insulation

Tan

Fibrous

Homogeneous

Chrysotile15%Cellulose60% 25.0% Non-fibrous (Other)

5BN-B/108

032401562-0011

Debris White

Non-Fibrous

Homogeneous

None DetectedCellulose4% 20%

25%

51.0%

Quartz

Gypsum

Non-fibrous (Other)

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA

600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.

Estimation of uncertainty is available on request.

Samples analyzed by EMSL Analytical, Inc. Long Island City, NY AIHA LAP, LLC-IHLAP Accredited #102581, NVLAP Lab Code 101048-9, CT PH-0170, MA AA000170

ASB_PLMwSigs_0007_0001 Printed:2/10/2024 12:50:57PM Page 2 of 3

Tel/Fax: (212) 290-0051 / (212) 290-0058…

This is the start of the file's text. The full file is on GovTribe.