S06 0009 - ATT 4 MH101.pdf
PDF 399 KB Posted
- Solicitation number
- 36C25223B0011
About this file
This solicitation is for renovations to the third floor of Building 406 at the VA Medical Center in Tomah, Wisconsin to convert it into a dementia unit. Key details include:
-
The solicitation number is 36C25223B0011 and is for project Z1DA--676-15-201. Bids are due by submitting the required information in accordance with Block 13 of the SF1442 form to the issuing office listed in Block 8 by March 7, 2023 at 1:00PM local time.
-
Site visits to review the existing space are scheduled for February 7, 2023 from 10:00AM to 11:15AM and are limited to the first eight people who RSVP to amy.burger@va.gov by February 3. COVID screening and protocols must be followed for visits to the patient floor.
-
The work involves renovating the third floor of Building 406 which is an inpatient unit. The solicitation is issued by the Department of Veterans Affairs and involves the Veterans Health Administration and Veterans Integrated Service Network 12.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DUCT PRESSURE CLASS, MATERIAL, & LEAKAGE
LEAKAGE TESTING
TO BE TESTEDSERVICE CONSTRUCTION
MATERIALS OF
(IN W.G.)
DUCT CONSTRUCTION
SMACNA
SEAL CLASS (% OF TAKE-OFF)
ALLOWABLE LEAKAGE
(IN W.G.)
TEST PRESSURE
44100AGALVANIZED4
PRESSURE CLASS PERCENT OF DUCT
42100AGALVANIZED2
42100AGALVANIZED-2
42100AGALVANIZED-2
42100AGALVANIZED/ ALUM2
SUPPLY AIR FROM AIR HANDLING UNIT
TO SUPPLY AIR TERMINAL
SUPPLY AIR FROM SUPPLY AIR
TERMINALS TO AIR OUTLETS
RETURN AIR FROM AIR INLET TO
AIR HANDLING UNIT OR FAN
OUTDOOR AIR FROM LOUVER
TO AIR HANDLING UNIT
EXHAUST AIR FROM FAN
TO EXHAUST LOUVER
42100AGALVANIZED2
RETURN AIR FROM FAN TO AIR
HANDLING UNIT AND RELIEF DAMPER
42100AGALVANIZED/ ALUM-2
GENERAL EXHAUST AIR
ALL INCLUSIVE
THOROUGHLY CLEAN ALL DUCTWORK AND AIR HANDLING EQUIPMENT, NEW
AND EXISTING, SUPPLY, RETURN, EXHAUST, RELIEF, OUTSIDE, FANS, COILS,
DAMPERS, ETC.; EXTENDING AS FAR INTO DUCTS AS CAN BE ACCESSED
WITH PROJECT RELATED DEMO AND NEW CONSTRUCTION. CLEAN EXISTING
DUCTWORK AND EQUIPMENT AS IT BECOMES ACCESSIBLE, CAP AND SEAL
TO PREVENT FURTHER CONTAMINATION, RECLEAN AS NECESSARY. CLEAN
ALL NEW DUCTWORK AS PART OF INSTALLATION WORK. THIS INCLUDES
ALL DUCTWORK AND EQUIPMENT AS DESCRIBED ABOVE FROM THE ATTIC
TO THE SECOND FLOOR. CLEANING TO ADDRESS MOLD WHEN
ENCOUNTERED, INCLUDING STERILIZATION. COORDINATE WITH VA COR,
DOCUMENTING AND REVIEWING FINDINGS.
DUCT CLEANING NOTE
1. DUCT, CHASE, AND SHAFT INFORMATION BASED ON EXISTING PLANS,
CONTRACTOR TO VERIFY ACTUAL INSTALLATION.
GENERAL NOTES
x
25x8 x x x
28x10 ø ø x
24x10
14x10
24x10
18x12
8x6 x x x x x
20x16 x
12x10 x
FD
FD
FD
FD
FD
22x18 UP
20x16 UP
12x10 UP
25x8 UP
20x16 UP
18x24 UP
FD
x x x
28x32 x x
8x6 x x x x
25x8 x x x
28x10 ø ø x
24x10
14x10
24x10
18x12
FD
FD
FD
10x8 UP
20x16 UP
24x18 UP
15x28 UP
18x28 UP
12x10 UP
28x32 UP
FD
FD
FD
FD
360 CFM
720/290 CFM
25x8 UP
FD
x x
10x8 x x x
16x12 UP
TO EF4-1
10x8 UP
TO EF3-1
18x12 UP
TO EF4-3
16x14 DN
FROM SF-4
16x12 UP
TO EF4-2
10x8 UP TO
EF4-4
x
12x6
14x8
24x16 SA UP
28x16 RA
UP TO RF-4
28x12
16x12
12x12
12x24 DN
FROM
AHU-5
24x18 UP
TO RF-5
TO 1ST FLR
IV FILL BIO
HOOD
S24
6C21
6C23
2629A
6C25
S23
2634A
2603A
2604A
6C22
26202621
S22
6C28
2659A
2658A
6C29
6C27
2644A
TV
T V
1 2
6 8 9 11 13
14 16 17 18
A
B
C
D
F
G.5
K
L
M
N
O
P
J
G
J.5
D.5
7.2 11.57.5 11.2
14.5
16.5
2.5 4.5
7 10
E
H
I
B406
ELEVATOR #1
2 2
2 2
2 2
2 2
2 2
S
S
S
1S
S S
S
S
S
S
S
S
S
S
S
S
S S
S
S S
S S
S
S
S S
S S
S S
S
S
S
S
S
S
S
SS
S
2 2
1/8" = 1'-0"
2ND FLOOR PLAN
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
PROJECT LEADER:
B
A
C
D
E
F
1 2 3 4 5 6 87 9
D
C
B
A
97 8654321
VA Medical Center Tomah, WI
Office of
Facilities
Management
B406
AUGUST 19, 2022
CONSULTANTS:
500 E. VETERANS ST.
TOMAH, WI 54660
MEDICAL CENTER
VETERANS AFFAIRS
FULLY SPRINKLERED
BUILDING 400
3770 S. Pennsylvania Avenue, Unit 8
St. Francis, Wisconsin 53235
E
F
ISSUED FOR BID
SECOND FLOOR KEY PLAN
A
B
C
D
E
MH101
JMD
MECHANICAL
2ND FLOOR DUCTWORK PLAN
HFB
PRE-BID DUCTWORK CLARIFICATION 3/3/2023
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231, OCT 1978
| Sheets and Views |
| MH101 |
File details come from the government source that posted it. Updated .