S02 - ATTACH 4 - 695-19-132 Drawing Set_BidPart-2.pdf

PDF 5 MB Posted

Attached to
Y1AZ--Construction Women's Clinic, Project #695-19-132
Solicitation number
36C25223B0004
Issued by

About this file

This solicitation is for construction services for a Women's Clinic project at the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12. Key details include that the solicitation number is 36C25223B0004 and is for Project #695-19-132 to construct a Women's Clinic located at 5000 W. National Ave, Milwaukee, WI 53295. The solicitation involves construction work including demolition, MEP work, hazard removal, and new construction that is to be completed simultaneously in phases to reduce disruption to occupied spaces. Multiple mobilizations are not permitted without approval from the Contracting Officer's Representative. The attached documents provide drawings, plans, and specifications for the project scope, including architectural, structural, mechanical, plumbing and electrical drawings.

View the file

Other files

File Type Posted
36C25223B0004 0007.docx DOCX document
ATTACH 19 Amendment 0007 rev.pdf PDF
ATTACH 16 Arch Drawings.pdf PDF
ATTACH 17 MEP Drawings.pdf PDF
ATTACH 15 Combined Spec Sections.pdf PDF
ATTACH 18 Furniture Dwg Shaft Photos Doc A.pdf PDF
36C25223B0004 0006.docx DOCX document
36C25223B0004 0005.docx DOCX document
S04 - Sign In Sheet.FE.pdf PDF
36C25223B0004 0004.docx DOCX document
S02 - ATTACH 1 - Construct Womens Clinic Project 695-19-132 Manual V1 rev Oct 28.pdf PDF
36C25223B0004 0003.docx DOCX document
S02 - ATTACH 2 - Construct Womens Clinic Project 695-19-132 Manual V2 rev.pdf PDF
36C25223B0004 0002.docx DOCX document
S02 - ATTACH 7 - 695-19-132 Drawing Set_BidPart-5.pdf PDF
S02 - ATTACH 5 - 695-19-132 Drawing Set_BidPart-3.pdf PDF
S02 - ATTACH 6 - 695-19-132 Drawing Set_BidPart-4.pdf PDF
S02 - ATTACH 3 - 695-19-132 Drawing Set_BidPart-1.pdf PDF
36C25223B0004 0001.docx DOCX document
S02 - ATTACH 9 - SSJ Bldg Automation HVAC Cntrl System rev_Executed.pdf PDF
S02 - ATTACH 13 - SSJ Interior Signage rev_Executed.pdf PDF
S02 - ATTACH 14 - Wage Determination WI202100001.pdf PDF
S02 - ATTACH 10 - SSJ Door Hardware rev_Executed.pdf PDF
S02 - ATTACH 11 - SSJ Fire Alarm System rev_Executed.pdf PDF
S02 - ATTACH 8 - 695-19-132 Drawing Set_BidPart-6.pdf PDF
S02 - ATTACH 12 - SSJ HID MultiClass Readers rev_Executed.pdf PDF
36C25223B0004_1.docx DOCX document
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SP SP

X U S RZAACCFFGG T

PROJECT LOCATION:

FIRST FLOOR

BUILDING 111 KEY PLAN

N

SHADE INDICATES

AREA NOT IN SCOPE,

TYP.

A. ABOVE CEILING WORK WHERE CEILINGS ARE TO REMAIN, CEILING TILES

SHALL BE REMOVED AND STORED IN A SAFE MANNER UNTIL CEILING TILES

CAN BE REINSTALLED. DAMAGED AND BROKEN CEILING TILES SHALL BE

REPLACED BY CONTRACTOR. GYPSUM BOARD CEILINGS SHALL BE PATCHED

AND PAINTED TO SEAMLESSLY MATCH EXISTING CEILING COLOR

FOLLOWING ABOVE CEILING DEMOLITION ACTIVITY. THIS SHALL INCLUDE

REPAIR TO THE CEILING GRID, SUSPENSION SYSTEM AND ALL ASSOCIATED

ASSEMBLIES AS WELL AS THE REPLACEMENT OF DAMAGED CEILING

PANELS, WITHIN AND BEYOND PROJECT LIMITS.

B. COORDINATE FULL SCOPE OF DEMOLITION WORK WITH ENGINEERING AND

VENDOR DRAWINGS.

C. WORK IN CORRIDORS TO TAKE PLACE DURING AFTER HOURS OF THE

FACILITY - COORDINATE WITH VA.

D. REMOVE ALL LIGHTING FIXTURES THROUGHOUT PROJECT BOUNDARY

UNLESS NOTED OTHERWISE. REFER TO ELECTRICAL DRAWINGS FOR

EXTENT AND LOCATIONS.

E. REMOVE ALL HVAC DIFFUSERS AND GRILLES THROUGHOUT PROJECT

BOUNDARY UNLESS NOTED OTHERWISE. REFER TO MECHANICAL DRAWINGS

FOR EXTENT AND LOCATIONS.

F. REMOVE ALL CEILING ASSEMBLIES THROUGHOUT PROJECT BOUNDARY

UNLESS NOTED OTHERWISE.

REFLECTED CEILING DEMOLITION GENERAL NOTES

SANITATION

COMMUNICATION

CENTER

MAIL

DISTRIBUTION

OFFICE

1409B

CANTEEN ADMIN

OFFICE

STORAGE

1409C

CASH COUNT

1409A

CORRIDOR

C1B08

TOILET FEMALE

TOILET MALE

PHARMACY

PROGRAM MGR.

1412B

SECRETARY

1412D

CLINICAL

SUPPORT MGR.

ELEVATOR

1-B-10

ELEVATOR

1-B-11

ELEVATOR

1-B-9

ELEVATOR

1-B-12

ELEVATOR

LOBBY

C1B07

CORRIDOR

C1B06

E L

E C

T R

IC

A

L

E C

STAIR

STR1-1

FIBER

WATER SOFTENER

RED CLINIC

WAITING

TRAYLINE

INTAKE

E L

E C

T R

IC

A

L

A E

C

PRIMARY

CARE LAB

SOILED

UTILITY

EXAM 16

EXAM 15

1638HALLWAY

C1CN05

RN OFFICE

EXAM 17

EXAM 14

TOILET

PATIENT

TOILET

PATIENT

PHARMACIST

HALLWAY

C1CN04

HALLWAY

C1CN03

EXAM 8

EXAM 7

EXAM 6

EXAM 5

EXAM 4

1617 EXAM 2

EXAM 1

HAC

TOILET

STAFF

HALLWAY

C1CN01

EXAM 3

RN INTERVIEW

RN INTERVIEW

RECEPTION

INTAKE

INTAKE

DIETICIAN

ELECTRICAL

1608EC

HALLWAY

16C1C09

ELECTRICAL

1657BEC

FIBER

1657C

STORAGE

BREAD & DESSERT

STAIR

STR 1-2

MEETING ROOM

CLEAN DISH

ROOM

SALAD

PREPARATION

KETTLE AREA

WARE WASH

HAC

TRAINING

CORRIDOR

C1C13

TOILET

FEMALE

GROUP ROOM

REFRIGERATION / MACHINERY

CANTEEN FREEZER

CANTEEN

REFRIGERATOR

CANTEEN DRY

STORAGE

FOOD PREP

& SERVICE

FROZEN

FOOD ICR

OVENS

CLASSROOM /

CONFERENCE

ADPAC /

TRAINING

HAC

1425C

FOOD STORAGE

1425A

FOOD STORAGE

1425B

CORRIDOR

C1B10

CANTEEN RETAIL

STORE

CANTEEN COLD

STORAGE

FOOD COURT

VENDING

E L

E C

T R

IC

A

L

A E

C

SANITATION

CORRIDOR

C1C15

REFLECTED CEILING DEMOLITION PLAN NOTES

1. REMOVE EXHAUST HOOD IN ITS ENTIRETY - REFER TO MEP

DRAWINGS.

2. EXISTING CEILING TO REMAIN - REFER TO MEP DRAWINGS FOR

EXTENT OF WORK.

3. EXISTING ACOUSTICAL CEILING TILE CEILING TO REMAIN. CLEAN

EXISTING GRID.

4. EXISTING DUMBWAITER SHAFT AND EQUIPMENT TO BE REMOVED.

CONTRACTOR TO FIELD VERIFY SLAB CONDITIONS WITH OPEN OR

CLOSED SLAB AT SHAFT LOCATIONS. COORDINATE WITH NEW

REFLECTED CEILING PLAN FOR SLAB INFILL DETAIL.

5. REMOVE ACOUSTICAL CEILING ASSEMBLY IN ITS ENTIRETY TO

ALLOW DEMOLITION OF MECHANICAL EQUIPMENT. PROVIDE

TEMPORARY SUPPORT HANGERS AT LOCATIONS WHERE EXISTING IS

TO REMAIN. SALVAGE FOR REINSTALLATION. REFER TO MEP

DRAWINGS FOR EXTENT.

6. SOLID LINE INDICATES BOUNDARY OF CEILING TO REMAIN.

COORDINATE WITH ARCHITECTURAL PLANS.

7. EXISTING EXHAUST HOOD - REFER TO MEP DRAWINGS FOR EXTENT

OF WORK.

RECESSED FLUORESCENT

HVAC RETURN AIR GRILLE

HVAC SUPPLY DIFFUSER

MECH/ELEC ITEMS: REFER TO MEP SHEETS AS APPLICABLE

RCP DEMOLITION SYMBOL LEGEND

ACOUSTICAL PANEL CEILING ASSEMBLY

TO BE REMOVED ENTIRELY

DEMOLITION SYMBOLS LEGEND

NO ARCHITECTURAL DEMOLITION OR NEW WORK

TO TAKE PLACE IN THIS AREA. REFER TO MEP

DRAWINGS FOR EXTENT OF DEMOLITION WORK.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.1

A v d c h ri s te n s e n M

N F

X

.r v t

/6 /2

:4

:0

P

M

AD110

FIRST FLOOR REFLECTED CEILING

DEMOLITION PLAN

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

CONSTRUCT WOMEN'S CLINIC

5000 W. NATIONAL AVE, MILWAUKEE, WI 53295

695-19-132

09/07/2022 JF DMC

100% BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/8" = 1'-0"AD110

1 FIRST FLOOR REFLECTED CEILING PLAN DEMOLITION PLAN - OVERALL

N

GENERAL NOTE:

ALL WORK TO BE COMPLETED SIMULTANEOUSLY (DEMOLITION - INCLUDING MEP, HAZMAT REMOVAL, NEW CONSTRUCTION - INCLUDING MEP) BY PHASE TO REDUCE DISRUPTION TO OCCUPIED SPACES. MULTIPLE MOBILIZATIONS ARE NOT PERMITTED WITHOUT COR APPROVAL. REFER TO SHEET GC101 AND MEP

DRAWINGS FOR PHASING PLAN.

Revisions: Date:

1 HR FIRE RATED

SMOKE PARTITION

WALL RATING LEGEND

EXISTING WALL UPGRADED TO 1

HOUR FIRE RATED

EXISTING 2 HOUR FIRE RATED

PROJECT LOCATION:

FIRST FLOOR

BUILDING 111 KEY PLAN

N

SHADE INDICATES

AREA NOT IN SCOPE,

TYP.

A. REFERENCE MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL

FOR COORDINATION ITEMS. COORDINATE AS REQUIRED INCLUDING

NECESSARY FRAMING, BLOCKING, ETC.

B. VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND

REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.

C. PATCH EXISTING WALLS WHERE NEW WALLS MEET.

D. ALL HANDRAILS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE

WITH ALL REQUIREMENTS OF AMERICANS WITH DISABILITIES ACT

GUIDELINES AND ALL CODES AND REGULATIONS HAVING JURISDICTION,

THE MOST STRINGENT SHALL PREVAIL.

E. PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER ABA REQUIREMENTS.

F. WHERE NO DIMENSION IS INDICATED, FINISH DOORS 6" FROM EDGE OF

STUD FRAMING AT CORNERS UNLESS OTHERWISE NOTED.

G. REFER TO SHEET QH100 FOR EQUIPMENT SCHEDULE AND INFORMATION.

H. REFER TO SHEET AI600 FOR ACCESSORIES TO BE PROVIDED IN THE

TOILET/BATH ROOMS AND AT THE HAND LAVATORIES.

I. LEVEL AND INFILL FLOOR SLAB TO RECEIVE NEW FLOORING. REFER TO

SPECIFICATIONS AND FLOORING MANUFACTURER'S TOLERANCES FOR

ADDITIONAL INFORMATION.

ARCHITECTURAL GENERAL NOTES

X U S RZAACCFFGG T

270 SF

VCS OFFICE

1465 81 SF

CASH OUT

1465B

121 SF

VCS CHIEF

OFFICE

1465A

110 SF

CONSULT

57 SF

PATIENT TOILET

1448A 168 SF

PROCEDURE

1448 67 SF

PATIENT TOILET

1452A

52 SF

SOILED HOLDING

173 SF

PROCEDURE

125 SF

EXAM

108 SF

EXAM

112 SF

EXAM

105 SF

EXAM

106 SF

EXAM

68 SF

FAMILY TOILET

1400A

82 SF

LACTATION

208 SF

CHECK-IN

90 SF

INTAKE

30 SF

LINEN CLOSET

129 SF

INTAKE

65 SF

PATIENT TOILET

134 SF

LAB

94 SF

CONSULT

92 SF

CLEAN STORAGE

56 SF

EQUIPMENT

43 SF

INTAKE - ALCOVE

209 SF

MENS TOILET

360 SF

RECEPTION /

WAITING

243 SF

WOMENS TOILET

77 SF

ELECTRICAL

54 SF

HAC

8 SF

WHEELCHAIR

STORAGE

1400B

548 SF

OPEN

WORKSTATIONS

187 SF

RESIDENT

WORKROOM

259 SF

CONFERENCE /

BREAK

88 SF

CORRIDOR

C1C10

85 SF

STAFF TOILET

143 SF

LOCKER ROOM

703 SF

CORRIDOR

C1C11

186 SF

SWING SPACE

747 SF

CORRIDOR

C1B06

141 SF

FAMILY WAITING

1400C

293 SF

CORRIDOR

C1C02

5794 SF

CORRIDOR

C1C09

305 SF

CORRIDOR

C1C03

1400A

1443 1447 1449

1448 1450

1451 C3

1452A

C6A

C

1465A

C

C

46 14

B 14

A

118 SF

CORRIDOR

C1C01

C6C

89 SF

INTAKE

61 SF

MEDS

25 SF

STORAGE

30 SF

CANISTER

STORAGE

97 SF

DRY STORAGE

1465B

C1

1448A

22 SF

ELECTRICAL

1403EC

A

209 SF

WHEELCHAIR

WASH

AE100.A

AE100.B

C8A

B

NOTE:

ONLY NEW ARCHITECTURAL WORK TO TAKE

PLACE IN THIS AREA IS THE INSTALL OF THE

CONSTRUCTION BARRIER ACCESS

CORRIDOR FOR STAFF ACCESS. THE WORK

IS TO TAKE PLACE PRIOR TO DEMOLITION OF

PHASE 1.

REFER TO SHEETS GC101 FOR MORE

INFORMATION.

C

C

D

NOTE:

SHADE INDUCATES LOCATION OF

EXISTING DUCT FOR COORDINATION.

ARCHITECTURAL SYMBOLS LEGEND

NO NEW ARCHITECTURAL WORK TO TAKE PLACE IN

THIS AREA. REFER TO MEP DRAWINGS FOR

EXTENT OF WORK.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.1

A v d c h ri s te n s e n M

N F

X

.r v t

/6 /2

:4

:2

P

M

AE100

FIRST FLOOR ARCHITECTURAL PLAN

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

CONSTRUCT WOMEN'S CLINIC

5000 W. NATIONAL AVE, MILWAUKEE, WI 53295

695-19-132

09/07/2022 JF DMC

100% BID DOCUMENTS

FULLY SPRINKLERED

N

SCALE: 1/8" = 1'-0"AE100

1 OVERALL ARCHITECTURAL PLAN

GENERAL NOTE:

ALL WORK TO BE COMPLETED SIMULTANEOUSLY (DEMOLITION - INCLUDING MEP, HAZMAT REMOVAL, NEW CONSTRUCTION - INCLUDING MEP) BY PHASE TO REDUCE DISRUPTION TO OCCUPIED SPACES. MULTIPLE MOBILIZATIONS ARE NOT PERMITTED WITHOUT COR APPROVAL. REFER TO SHEET GC101 AND MEP

PROJECT LOCATION:

FIRST FLOOR

BUILDING 111 KEY PLAN

N

SHADE INDICATES

AREA NOT IN SCOPE,

TYP.

A. REFERENCE MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL

FOR COORDINATION ITEMS. COORDINATE AS REQUIRED INCLUDING

NECESSARY FRAMING, BLOCKING, ETC.

B. VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND

REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.

C. PATCH EXISTING WALLS WHERE NEW WALLS MEET.

D. ALL HANDRAILS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE

WITH ALL REQUIREMENTS OF AMERICANS WITH DISABILITIES ACT

GUIDELINES AND ALL CODES AND REGULATIONS HAVING JURISDICTION,

THE MOST STRINGENT SHALL PREVAIL.

E. PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER ABA REQUIREMENTS.

F. WHERE NO DIMENSION IS INDICATED, FINISH DOORS 6" FROM EDGE OF

STUD FRAMING AT CORNERS UNLESS OTHERWISE NOTED.

G. REFER TO SHEET QH100 FOR EQUIPMENT SCHEDULE AND INFORMATION.

H. REFER TO SHEET AI600 FOR ACCESSORIES TO BE PROVIDED IN THE

TOILET/BATH ROOMS AND AT THE HAND LAVATORIES.

I. LEVEL AND INFILL FLOOR SLAB TO RECEIVE NEW FLOORING. REFER TO

SPECIFICATIONS AND FLOORING MANUFACTURER'S TOLERANCES FOR

ADDITIONAL INFORMATION.

ARCHITECTURAL GENERAL NOTES

1 HR FIRE RATED

SMOKE PARTITION

WALL RATING LEGEND

EXISTING WALL UPGRADED TO 1

HOUR FIRE RATED

EXISTING 2 HOUR FIRE RATED

X U S RZAACC T

110 SF

CONSULT

57 SF

PATIENT TOILET

1448A

168 SF

PROCEDURE

67 SF

PATIENT TOILET

1452A

52 SF

SOILED HOLDING

173 SF

PROCEDURE

125 SF

EXAM

108 SF

EXAM

112 SF

EXAM

105 SF

EXAM

106 SF

EXAM

68 SF

FAMILY TOILET

1400A

82 SF

LACTATION

208 SF

CHECK-IN

90 SF

INTAKE

30 SF

LINEN CLOSET

129 SF

INTAKE

65 SF

PATIENT TOILET

134 SF

LAB

94 SF

CONSULT

92 SF

CLEAN STORAGE

56 SF

EQUIPMENT

43 SF

INTAKE - ALCOVE

CLR

6' - 0"

C

LR

6'

209 SF

MENS TOILET

360 SF

RECEPTION /

WAITING

243 SF

WOMENS TOILET

54 SF

HAC

8 SF

WHEELCHAIR

STORAGE

1400B

259 SF

CONFERENCE /

BREAK

88 SF

CORRIDOR

C1C10

85 SF

STAFF TOILET

143 SF

LOCKER ROOM

703 SF

CORRIDOR

C1C11

186 SF

SWING SPACE

747 SF

CORRIDOR

C1B06

141 SF

FAMILY WAITING

1400C

293 SF

CORRIDOR

C1C02

5794 SF

CORRIDOR

C1C09

305 SF

CORRIDOR

C1C03

1400A

14351437

1443 1447 1449

1448 1450

C3

1452A

C6A

C

C

46 14

B

A

118 SF

CORRIDOR

C1C01

89 SF

INTAKE

61 SF

MEDS

25 SF

STORAGE

C1

S3A.1F

7'

/4

9'

1/ 2"

3/ 4"

1'

/4

6'

3/ 4"

/4

5'

3/ 4"

7'

1/ 2"

10' - 4" 6' - 5" 5' - 9 3/4" 7' - 9 3/4"

11' - 6" 9' - 10 3/4" 10' - 3 1/2" 9' - 8 3/4" 9' - 4"

/4

7'

/4

7'

3/ 4"

11' - 8 3/4" 6' - 5" 7' - 11 1/4"

1' - 1"

7' - 11 3/4" 11' - 10 1/2" 9' - 7 1/2" 9' - 5"

/4

3'

S3A.1Fi

S3A.1F

7'

C

LE

A R

7'

/2

S3A.1FiS3A.1F

/4

2'

/4

2'

11' - 8 1/2" 16' - 5 1/4" 11' - 6 1/2"

2'

/4

8'

/4

/4

1' - 6"1' - 6"

15' - 4 1/4" 15' - 1" 5' - 5" 11' - 6 1/2"

3'

/2

3' - 10"

1448A

5'

/2

22 SF

ELECTRICAL

1403EC

3'

2' - 6"

2' - 3"2' - 3"3' - 0"2' - 3"3' - 0"

1' - 6"1' - 6"

E Q

E Q

E Q

E Q

S3A.1Fi

A

F3A.Gi

S3B.SPi

S3A.Gi

S3B.SPi

S3A.1F

S3A.Gi

S3B.SPi

S3A.Gi

S3A.Gi

AE400

SIM

AE400

SIM

AE400

SIM

AE400

SIM

F3D.G

F3D.G

F0D.G

S3A.GiS3A.Gi

F3A.Gi

F3A.Gi

S3A.GiS3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.1F

S3A.Gi

S3A.1Fi

S3A.Gi

S3B.SPi

S3A.1Fi

S3A.2Gi

S3A.2Gi

S3A.2Gi

S3A.2Gi

S3A.2Gi

S3A.2Gi

S3A.2Gi

S3A.2Gi

S3A.2Gi

S3A.Gi

Room

209 SF

WHEELCHAIR

WASH

AE400

AE400

AE400

AE400

AE400

AE400

5'

/4

E Q

E Q

AE400

SIM

AE400

1'

1'

CLEAR

5' - 0"

S3A.G

B

AE401

C

C

D

6 6

6 6

7 7

7 7

FD

S3A.Gi

S3A.Gi

8'

/2

ARCHITECTURAL SYMBOLS LEGEND

NO NEW ARCHITECTURAL WORK TO TAKE PLACE IN

THIS AREA. REFER TO MEP DRAWINGS FOR

EXTENT OF WORK.

ARCHITECTURAL PLAN NOTES

1. CONTRACTOR TO UPGRADE EXISTING WALL TO 1 HR FIRE BARRIER BY

EXTENDING GYP TO DECK, ADDING FIRE CAULKING TO ALL PENETRATIONS

AND FIRE SAFING TO FILL FLUTES OF DECK - REFER TO SHEET AE400 FOR

WALL CONSTRUCTION DETAIL.

2. ALIGN WALL FINISHES.

3. PASS THRU CABINET - REFER TO ELEVATION.

4. WALL FINISH TO MATCH ADJACENT WALLS. REFER TO AI SERIES DRAWINGS

FOR FINISH.

5. SHADE INDICATES EXISTING DUCT ABOVE. WALL FRAMING TO STOP SHORT

OF DUCTWORK AT INTERSECTING LOCATIONS. INSTALL FOAM ISOLATOR

BETWEEN TOP OF WALL AND DUCTWORK FOR VIBRATION MITIGATION.

REFER TO DETAIL 10/AE400.

6. INSTALL 3 5/8" METAL STUD CORNER BRACE FRAMING ABOVE CEILING IN

LOCATION INDICATED ON PLAN.

7. ADJUST WALL FRAMING AS NECESSARY TO ACCEPT RECESSED

ACCESSORY.

8. FLOOR DRAIN - REFER TO PLUMBING DRAWINGS. SLOPE FLOOR TO DRAIN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.1

A v d c h ri s te n s e n M

N F

X

.r v t

/6 /2

:4

:3

P

M

AE100.A

ENLARGED FIRST FLOOR ARCHITECTURAL

PLAN - AREA A

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

CONSTRUCT WOMEN'S CLINIC

5000 W. NATIONAL AVE, MILWAUKEE, WI 53295

695-19-132

09/07/2022 JF DMC

100% BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"AE100.A

1 ENLARGED ARCHITECTURAL PLAN - AREA A

N

GENERAL NOTE:

ALL WORK TO BE COMPLETED SIMULTANEOUSLY (DEMOLITION - INCLUDING MEP, HAZMAT REMOVAL, NEW CONSTRUCTION - INCLUDING MEP) BY PHASE TO REDUCE DISRUPTION TO OCCUPIED SPACES. MULTIPLE MOBILIZATIONS ARE NOT PERMITTED WITHOUT COR APPROVAL. REFER TO SHEET GC101 AND MEP

A. REFERENCE MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL

FOR COORDINATION ITEMS. COORDINATE AS REQUIRED INCLUDING

NECESSARY FRAMING, BLOCKING, ETC.

B. VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND

REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.

C. PATCH EXISTING WALLS WHERE NEW WALLS MEET.

D. ALL HANDRAILS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE

WITH ALL REQUIREMENTS OF AMERICANS WITH DISABILITIES ACT

GUIDELINES AND ALL CODES AND REGULATIONS HAVING JURISDICTION,

THE MOST STRINGENT SHALL PREVAIL.

E. PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER ABA REQUIREMENTS.

F. WHERE NO DIMENSION IS INDICATED, FINISH DOORS 6" FROM EDGE OF

STUD FRAMING AT CORNERS UNLESS OTHERWISE NOTED.

G. REFER TO SHEET QH100 FOR EQUIPMENT SCHEDULE AND INFORMATION.

H. REFER TO SHEET AI600 FOR ACCESSORIES TO BE PROVIDED IN THE

TOILET/BATH ROOMS AND AT THE HAND LAVATORIES.

I. LEVEL AND INFILL FLOOR SLAB TO RECEIVE NEW FLOORING. REFER TO

SPECIFICATIONS AND FLOORING MANUFACTURER'S TOLERANCES FOR

ADDITIONAL INFORMATION.

ARCHITECTURAL GENERAL NOTES

ARCHITECTURAL PLAN NOTES

1. ALIGN WALL FINISHES.

2. ALIGN FACE OF STUD TO COLUMN FACE.

1 HR FIRE RATED

SMOKE PARTITION

WALL RATING LEGEND

EXISTING WALL UPGRADED TO 1

HOUR FIRE RATED

EXISTING 2 HOUR FIRE RATED

PROJECT LOCATION:

FIRST FLOOR

BUILDING 111 KEY PLAN

N

SHADE INDICATES

AREA NOT IN SCOPE,

TYP.

X UZAA

270 SF

VCS OFFICE

81 SF

CASH OUT

1465B

121 SF

VCS CHIEF

OFFICE

1465A

77 SF

ELECTRICAL

54 SF

HAC

548 SF

OPEN

WORKSTATIONS

187 SF

RESIDENT

WORKROOM

85 SF

STAFF TOILET

703 SF

CORRIDOR

C1C11

C

1465A

30 SF

CANISTER

STORAGE

97 SF

DRY STORAGE

1465B

1/ 4"

9'

/4

E Q

E Q

2'

/4

2'

/2

CLEAR

8' - 0"

28' - 1 3/4" 11' - 6 1/2"

/4

/4

1"

C

LE

A R

8'

9' - 8 1/2" 22' - 1" 9' - 4 3/4"

9'

/4

3'

27' - 10 1/2"

S3A.1F

S3A.1F

S3B.SPMi

4' - 6 3/4"

S3A.Gi

S3A.Gi

S3A.Gi

S3A.G

S3A.Gi

S3B.SPMi S3B.SPMi

S3A.1Fi

F3D.G

S3A.GMi

2'

F0A.GM F0D.G F0D.G

S3A.G

F3D.G

CLEAR

5' - 0"

F3A.Gi

F3A.Gi 1' - 6" 1' - 6"

C8A

4'

S3A.G

S3B.SPi

INSTALL CONTINUOUS SECURITY MESH TO

EXISTING WALLS TO CREATE CONTINUOUS

BARRIER AROUND PERIMETER - REFER TO WALL

TYPE S3A.GMi ON SHEET AE002

S3B.SPi

S3B.SPi

ARCHITECTURAL SYMBOLS LEGEND

NO NEW ARCHITECTURAL WORK TO TAKE PLACE IN

THIS AREA. REFER TO MEP DRAWINGS FOR

EXTENT OF WORK.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.1

A v d c h ri s te n s e n M

N F

X

.r v t

/6 /2

:4

:3

P

M

AE100.B

ENLARGED FIRST FLOOR ARCHITECTURAL

PLAN - AREA B

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

CONSTRUCT WOMEN'S CLINIC

5000 W. NATIONAL AVE, MILWAUKEE, WI 53295

695-19-132

09/07/2022 JF DMC

100% BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"AE100.B

1 ENLARGED ARCHITECTURAL PLAN - AREA B

N

GENERAL NOTE:

ALL WORK TO BE COMPLETED SIMULTANEOUSLY (DEMOLITION - INCLUDING MEP, HAZMAT REMOVAL, NEW CONSTRUCTION - INCLUDING MEP) BY PHASE TO REDUCE DISRUPTION TO OCCUPIED SPACES. MULTIPLE MOBILIZATIONS ARE NOT PERMITTED WITHOUT COR APPROVAL. REFER TO SHEET GC101 AND MEP

OS OS

SD

SD

C

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS OS

OS

OS OS

OS OS OS

OS

OS

OS

OS

OS

OS

OS

OS

X U S RZAACCFFGG T

VCS OFFICE

CASH OUT

1465B

VCS CHIEF

OFFICE

1465A

LACTATION

FAMILY TOILET

1400A

RECEPTION /

WAITING

FAMILY WAITING

1400C

CHECK-IN

INTAKE

INTAKE

CORRIDOR

C1C01

PATIENT TOILET

LAB

CONSULT

EQUIPMENT

CLEAN STORAGE

CORRIDOR

C1C02

EXAM

EXAM

EXAM

EXAM

EXAM

PROCEDURE

PATIENT TOILET

1452A

SOILED HOLDING

PROCEDURE

PATIENT TOILET

1448A

CONSULT

CORRIDOR

C1C03

MENS TOILET

WOMENS TOILET

CORRIDOR

C1B06

CORRIDOR

C1C09

OPEN

WORKSTATIONS

CORRIDOR

C1C11

ELECTRICAL

HAC

LOCKER ROOM

STAFF TOILET

RESIDENT

WORKROOM

CONFERENCE /

BREAK

CORRIDOR

C1C10

ELECTRICAL

1403EC

SWING SPACE

MEDS

INTAKE

LINEN CLOSET

STORAGE

DRY STORAGE

CANISTER

STORAGE

WHEELCHAIR

WASH

AE110.A

AE110.B

INTAKE - ALCOVE

SPSP

SP

SP

SP

SP SP SP

SP SP SP SP SP SP

SP

SP

SP

SP

SP

SP

SP

SP SP

SP

SP

SP

SP

SP

SPSP

SP

SP

SP

SP

SP

SP

SP

SP

SP

NOTE:

ONLY NEW ARCHITECTURAL WORK TO TAKE

PLACE IN THIS AREA IS THE INSTALL OF THE

CONSTRUCTION BARRIER ACCESS

CORRIDOR FOR STAFF ACCESS. THE WORK

IS TO TAKE PLACE PRIOR TO DEMOLITION OF

PHASE 1.

REFER TO SHEETS GC101 FOR MORE

INFORMATION.

NOTE:

SHADE INDICATES LOCATION OF

EXISTING DUCT FOR COORDINATION.

NOTE:

SHADE INDICATES LOCATION OF

EXISTING DUCT FOR COORDINATION.

PROJECT LOCATION:

FIRST FLOOR

BUILDING 111 KEY PLAN

N

SHADE INDICATES

AREA NOT IN SCOPE,

TYP.

A. THE ARCHITECTURAL REFLECTED CEILING PLAN SHALL GOVERN THE

LAYOUT OF ALL CEILING ELEMENTS, HEIGHTS AND/OR PENETRATIONS.

COORDINATION OF THE ARCHITECTURAL AND ENGINEERING ELEMENTS ARE

THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS TO

VERIFY FIELD CONDITIONS AND REPORTS ANY DISCREPANCIES TO

ARCHITECT AND COR.

B. SHOWN SIZES OF MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT

ARE FOR REFERENCE ONLY. REFER TO ENGINEERING PLANS FOR

ADDITIONAL INFORMATION. COORDINATE SCOPE OF WORK WITH

ENGINEERING DRAWINGS, UNLESS OTHERWISE NOTED.

C. ACOUSTIC PANEL CEILING SHALL BE CENTERED IN THE ROOM AND

INSTALLED TO ELIMINATE NARROW CUT STRIPS OF PANELS ALONG THE

EDGES OF WALLS AND BULKHEADS, UNLESS OTHERWISE NOTED.

COORDINATE WITH THE LIGHTING LAYOUT. THE LIGHTING SHALL BE

CENTERED IN ROOMS.

D. CEILING MOUNTED ITEMS (SPRINKLER HEADS, MOUNTING DEVICES, ETC.)

SHALL BE CENTERED IN THE CEILING PANELS UNLESS NOTED OTHERWISE.

E. ABOVE CEILING WORK REQUIRED BEYOND THE SCOPE OF THE WORK SHALL

BE COORDINATED WITH PATIENT SAFETY, INFECTION CONTROL, AND COR.

F. CEILING TILE REMOVED IN ORDER TO COMPLETE ABOVE CEILING WORK

SHALL BE STORED IN A SAFE DRY LOCATION. DAMAGED OR BROKEN CEILING

TILES SHALL BE REPLACED. DRYWALL CEILINGS SHALL BE PATCHED,

PREPPED AND NEW FINISH APPLIED TO MATCH EXISTING.

G. REFER TO FINISHES SHEETS AND SPECIFICATIONS FOR INFORMATION ON

GYPSUM BOARD PAINT FINISH.

H. WHERE NEW CEILINGS ARE INSTALLED AND SPRINKLERS ARE EXISTING TO

REMAIN, SPRINKLERS SHALL BE ADJUSTED TO NEW CEILING HEIGHTS, WHEN

APPLICABLE.

REFLECTED CEILING GENERAL NOTES

A

TYPE GRAPHIC DESCRIPTION

B

2x2 ACOUSTICAL CEILING TILE (AT-1 & AT-2).

REFER TO ROOM FINISH SCHEDULE

GYPSUM BOARD CEILING. CEILING PAINT.

REFLECTED CEILING PLAN TYPE LEGEND

EXISTING CEILING / NO CEILING

2 1/2" METAL STUD BRACING AT 32" O.C.

ANCHOR TO STRUCTURE ABOVE

5/8" TYPE "X" GYPSUM BOARD

3-5/8" METAL STUD FRAMING AT 16" O.C.

ANCHOR TO STRUCTURE ABOVE

V A

R

IE

S 6"

M

IN

REFER TO REFLECTED CEILING PLAN

VARIES

BOTTOM OF BULKHEAD

VARIES

BOTTOM OF CEILING

VARIES

5/8" TYPE "X" GYPSUM BOARD

REFER TO REFLECTED CEILING PLAN

VARIES

2 1/2" METAL STUD BRACING AT 32" O.C.

ANCHOR TO STRUCTURE ABOVE

5/8" TYPE "X" GYPSUM BOARD

3-5/8" METAL STUD FRAMING AT 16" O.C.

ANCHOR TO STRUCTURE ABOVE

TYPICAL WALL CONSTRUCTION,

RE: FLOOR PLAN AND WALL TYPES

FOR ADDITIONAL INFORMATION

BOTTOM OF BULKHEAD

VARIES

BOTTOM OF CEILING

VARIES

6" M

IN

V A

R

IE

S

6" M

IN

V A

R

IE

S

2 1/2" METAL STUD BRACING ON BOTH

SIDES AT 48" O.C. - MIN. 3 LOCATIONS.

ANCHOR TO STRUCTURE ABOVE

5/8" TYPE "X" GYPSUM BOARD

4 7/8"

3-5/8" METAL STUD FRAMING AT 16" O.C.

ANCHOR TO STRUCTURE ABOVE

BOTTOM OF BULKHEAD

VARIES

BOTTOM OF CEILING

VARIES

1 HR FIRE RATED

SMOKE PARTITION

WALL RATING LEGEND

EXISTING WALL UPGRADED TO 1

HOUR FIRE RATED

EXISTING 2 HOUR FIRE RATED

REFER TO PLANS FOR SIZE

EPOXY EXPANSION ANCHORS

w/ 1/2" HILTED QUICK BOLTS

FIBER-REINFORCED CONCRETE

INFILL

#4 BARS x 8" LONG SMOOTH STEEL DOWELS w/ SLIP CAP ON

ONE END - 24" O.C.

EXISTING CONCRETE SLAB

1/4" THICK STEEL PLATE -

SET IN A BED OF SEALANT.

SEAL PERIMETER OF PLATE

ARCHITECTURAL SYMBOLS LEGEND

NO NEW ARCHITECTURAL WORK TO TAKE PLACE IN

THIS AREA. REFER TO MEP DRAWINGS FOR

EXTENT OF WORK.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.1

A v d c h ri s te n s e n M

N F

X

.r v t

/6 /2

:4

:3

P

M

AE110

OVERALL FIRST FLOOR REFLECTED CEILING

PLAN

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

CONSTRUCT WOMEN'S CLINIC

5000 W. NATIONAL AVE, MILWAUKEE, WI 53295

695-19-132

09/07/2022 JF DMC

100% BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/8" = 1'-0"AE110

1 OVERALL REFLECTED CEILNG PLAN

SCALE: 1 1/2" = 1'-0"AE110

3 TYPICAL BULKHEAD DETAIL

SCALE: 1 1/2" = 1'-0"AE110

4 TYPICAL BULKHEAD DETAIL

SCALE: 1 1/2" = 1'-0"AE110

2 TYPICAL BULKHEAD DETAIL - SINGLE STUD

N

SCALE: 1 1/2" = 1'-0"AE110

5 INFILL CONCRETE SLAB DETAIL

GENERAL NOTE:

ALL WORK TO BE COMPLETED SIMULTANEOUSLY (DEMOLITION - INCLUDING MEP, HAZMAT REMOVAL, NEW CONSTRUCTION - INCLUDING MEP) BY PHASE TO REDUCE DISRUPTION TO OCCUPIED SPACES. MULTIPLE MOBILIZATIONS ARE NOT PERMITTED WITHOUT COR APPROVAL. REFER TO SHEET GC101 AND MEP

C

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS OS

OS

OS

OS OS OS

OS

OS

OS

OS

OS

OS

X U S RZAACC T

A 9' - 0"

B 8'

0"

B 7'

82 SF

LACTATION

68 SF

FAMILY TOILET

1400A

360 SF

RECEPTION /

WAITING

141 SF

FAMILY WAITING

1400C

208 SF

CHECK-IN

143290 SF

INTAKE

129 SF

INTAKE

118 SF

CORRIDOR

C1C01

A 9'

0"

A 9'

0"

A 9'

0"

A 9'

0"

A 9'

0"

A 9'

0"

A 9' - 0" A 9' - 0" A 9' - 0" A 9' - 0"

A 9' - 0"B 9' - 0"

B 9'

0"

B 9' - 0"

A 9' - 0"

A 8' - 6"

A 9' - 0"

A 9' - 0"

65 SF

PATIENT TOILET

134 SF

LAB

94 SF

CONSULT

56 SF

EQUIPMENT

92 SF

CLEAN STORAGE

293 SF

CORRIDOR

C1C02

125 SF

EXAM

1443 108 SF

EXAM

112 SF

EXAM

1447 105 SF

EXAM

106 SF

EXAM

173 SF

PROCEDURE

67 SF

PATIENT TOILET

1452A

52 SF

SOILED HOLDING

168 SF

PROCEDURE

57 SF

PATIENT TOILET

1448A

110 SF

CONSULT

305 SF

CORRIDOR

C1C03

209 SF

MENS TOILET

243 SF

WOMENS TOILET

747 SF

CORRIDOR

C1B06

5794 SF

CORRIDOR

C1C09

54 SF

HAC

143 SF

LOCKER ROOM

85 SF

STAFF TOILET

259 SF

CONFERENCE /

BREAK

88 SF

CORRIDOR

C1C10

A 9' - 0"

A 9'

0"

A 9'

0"

A 9'

0"

A 9'

0"

A 9' - 0"

A 7' - 9"

A 8' - 0"

A 8' - 0"

A 9' - 0"

A 9'

0"

A 9'

0"

22 SF

ELECTRICAL

1403EC

186 SF

SWING SPACE

A 8'

0"

A 9'

0"

A 9' - 0"61 SF

MEDS

89 SF

INTAKE

30 SF

LINEN CLOSET

A 9' - 0"

A 9'

0"

A 9' - 0"

A 9' - 0"

A 9'

0"

A 9'

0"

25 SF

STORAGE

B 8'

6"

B 8' - 6"

B 7'

3A 9' - 0"

A 9' - 0"

AE110

AE110

AE110

B 7' - 7"

B 8' - 6"

B 8' - 6"

P-4

AE110

AE110

A 9' - 0"

AE110

B 7' - 7"

209 SF

WHEELCHAIR

WASH

B 7' - 10"

AE110

B 7' - 10"

B 7' - 10"

11 1/2"

A

LI

G N

ALIGN

AE110ALIGN

ALIGN

1'

2'

/4

EQ EQ

E Q

E Q

AE401

AE110

B 8' - 4"

EQ EQ

E Q

E Q

A 9' - 0"

43 SF

INTAKE - ALCOVE

EQ EQ

SPSP

SP

SP

SP

SP SP SP

SP

SP SP SP SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SD

SP

SP

SP

A 9'

0"

C

C OS

3/

4"

7 7

7 7

V.I.F.

12' - 0" +/-

V.I.F.

12' - 0" +/-

V.I.F.

12' - 0" +/-

V .I.

F

7'

V .I.

F

7'

AE110

B 7' - 7"

1. INSTALL 360 DEGREE DOME MIRROR. CENTER DOME TO DOOR ALCOVE AND

CENTER IN CORRIDOR.

2. INSTALL H TRACK PATIENT LIFT - REFER TO SHEET AE401 FOR MOUNTING

DETAILS.

3. INSTALL CUBICLE CURTAIN TRACK.

4. EXISTING ACOUSTICAL CEILING SYSTEM.

5. INSTALL 180 DEGREE DOME MIRROR. CENTER TO CORRIDOR.

6. SHADE INDICATES EXISTING DUCT ABOVE. WALL FRAMING TO STOP SHORT

OF DUCTWORK. INSTALL FOAM ISOLATOR BETWEEN TOP OF WALL AND

DUCTWORK FOR VIBRATION MITIGATION. INSTALL LAY-IN SOUND BATT

INSULATION ABOVE CEILING BETWEEN DUCTWORK - FULL LENGTH AND

WIDTH.

7. INSTALL 3 5/8" METAL STUD CORNER BRACE FRAMING ABOVE CEILING IN

LOCATION INDICATED ON PLAN.

8. GYPSUM CEILING ASSEMBLY TO BE 1HR FIRE RATED - REFER TO DETAIL

11/AE400.

9. EXHAUST HOOD - REFER TO MECHANICAL DRAWIGNS FOR MORE

INFORMATION.

REFLECTED CEILING NOTES #

A. THE ARCHITECTURAL REFLECTED CEILING PLAN SHALL GOVERN THE

LAYOUT OF ALL CEILING ELEMENTS, HEIGHTS AND/OR PENETRATIONS.

COORDINATION OF THE ARCHITECTURAL AND ENGINEERING ELEMENTS ARE

THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS TO

VERIFY FIELD CONDITIONS AND REPORTS ANY DISCREPANCIES TO

ARCHITECT AND COR.

B. SHOWN SIZES OF MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT

ARE FOR REFERENCE ONLY. REFER TO ENGINEERING PLANS FOR

ADDITIONAL INFORMATION. COORDINATE SCOPE OF WORK WITH

ENGINEERING DRAWINGS, UNLESS OTHERWISE NOTED.

C. ACOUSTIC PANEL CEILING SHALL BE CENTERED IN THE ROOM AND

INSTALLED TO ELIMINATE NARROW CUT STRIPS OF PANELS ALONG THE

EDGES OF WALLS AND BULKHEADS, UNLESS OTHERWISE NOTED.

COORDINATE WITH THE LIGHTING LAYOUT. THE LIGHTING SHALL BE

CENTERED IN ROOMS.

D. CEILING MOUNTED ITEMS (SPRINKLER HEADS, MOUNTING DEVICES, ETC.)

SHALL BE CENTERED IN THE CEILING PANELS UNLESS NOTED OTHERWISE.

E. ABOVE CEILING WORK REQUIRED BEYOND THE SCOPE OF THE WORK SHALL

BE COORDINATED WITH PATIENT SAFETY, INFECTION CONTROL, AND COR.

F. CEILING TILE REMOVED IN ORDER TO COMPLETE ABOVE CEILING WORK

SHALL BE STORED IN A SAFE DRY LOCATION. DAMAGED OR BROKEN CEILING

TILES SHALL BE REPLACED. DRYWALL CEILINGS SHALL BE PATCHED,

PREPPED AND NEW FINISH APPLIED TO MATCH EXISTING.

G. REFER TO FINISHES SHEETS AND SPECIFICATIONS FOR INFORMATION ON

GYPSUM BOARD PAINT FINISH.

H. WHERE NEW CEILINGS ARE INSTALLED AND SPRINKLERS ARE EXISTING TO

REMAIN, SPRINKLERS SHALL BE ADJUSTED TO NEW CEILING HEIGHTS, WHEN

APPLICABLE.

REFLECTED CEILING GENERAL NOTES

A

TYPE GRAPHIC DESCRIPTION

B

2x2 ACOUSTICAL CEILING TILE (AT-1 & AT-2).

REFER TO ROOM FINISH SCHEDULE

GYPSUM BOARD CEILING. CEILING PAINT.

REFLECTED CEILING PLAN TYPE LEGEND

EXISTING CEILING / NO CEILING

1 HR FIRE RATED

SMOKE PARTITION

WALL RATING LEGEND

EXISTING WALL UPGRADED TO 1

HOUR FIRE RATED

EXISTING 2 HOUR FIRE RATED

PROJECT LOCATION:

FIRST FLOOR

BUILDING 111 KEY PLAN

N

SHADE INDICATES

AREA NOT IN SCOPE,

TYP.

ARCHITECTURAL SYMBOLS LEGEND

NO NEW ARCHITECTURAL WORK TO TAKE PLACE IN

THIS AREA. REFER TO MEP DRAWINGS FOR

EXTENT OF WORK.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.1

A v d c h ri s te n s e n M

N F

X

.r v t

/6 /2

:4

:4

P

M

AE110.A

ENLARGED REFLECTED CEILING PLAN - AREA

A

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

CONSTRUCT WOMEN'S CLINIC

5000 W. NATIONAL AVE, MILWAUKEE, WI 53295

695-19-132

09/07/2022 JF DMC

100% BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"AE110.A

1 ENLARGED REFLECTED CEILNG PLAN - AREA A

N

GENERAL NOTE:

ALL WORK TO BE COMPLETED SIMULTANEOUSLY (DEMOLITION - INCLUDING MEP, HAZMAT REMOVAL, NEW CONSTRUCTION - INCLUDING MEP) BY PHASE TO REDUCE DISRUPTION TO OCCUPIED SPACES. MULTIPLE MOBILIZATIONS ARE NOT PERMITTED WITHOUT COR APPROVAL. REFER TO SHEET GC101 AND MEP

OS OS

OS

OS

OS

X UZAA

270 SF

VCS OFFICE

81 SF

CASH OUT

1465B121 SF

VCS CHIEF

OFFICE

1465A

A 9'

0"

A 9' - 0" A 9' - 0"

548 SF

OPEN

WORKSTATIONS

703 SF

CORRIDOR

C1C11

77 SF

ELECTRICAL

54 SF

HAC

85 SF

STAFF TOILET

187 SF

RESIDENT

WORKROOM

A 8' - 0"

A 9' - 0"

A 9'

0"

A 9'

0" A 8' - 0"

A 9'

0"

A 9'

0"

A 9' - 0"

97 SF

DRY STORAGE

30 SF

CANISTER

STORAGE

AE110 B 7' - 10"

AE110

B 7' - 10"

AE110

SP SP

SP

SP

SP

SP

SPSP

SP

SP

SP

B 8' - 6"

A

LI

G N

A. THE ARCHITECTURAL REFLECTED CEILING PLAN SHALL GOVERN THE

LAYOUT OF ALL CEILING ELEMENTS, HEIGHTS AND/OR PENETRATIONS.

COORDINATION OF THE ARCHITECTURAL AND ENGINEERING ELEMENTS ARE

THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS TO

VERIFY FIELD CONDITIONS AND REPORTS ANY DISCREPANCIES TO

ARCHITECT AND COR.

B. SHOWN SIZES OF MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT

ARE FOR REFERENCE ONLY. REFER TO ENGINEERING PLANS FOR

ADDITIONAL INFORMATION. COORDINATE SCOPE OF WORK WITH

ENGINEERING DRAWINGS, UNLESS OTHERWISE NOTED.

C. ACOUSTIC PANEL CEILING SHALL BE CENTERED IN THE ROOM AND

INSTALLED TO ELIMINATE NARROW CUT STRIPS OF PANELS ALONG THE

EDGES OF WALLS AND BULKHEADS, UNLESS OTHERWISE NOTED.

COORDINATE WITH THE LIGHTING LAYOUT. THE LIGHTING SHALL BE

CENTERED IN ROOMS.

D. CEILING MOUNTED ITEMS (SPRINKLER HEADS, MOUNTING DEVICES, ETC.)

SHALL BE CENTERED IN THE CEILING PANELS UNLESS NOTED OTHERWISE.

E. ABOVE CEILING WORK REQUIRED BEYOND THE SCOPE OF THE WORK SHALL

BE COORDINATED WITH PATIENT SAFETY, INFECTION CONTROL, AND COR.

F. CEILING TILE REMOVED IN ORDER TO COMPLETE ABOVE CEILING WORK

SHALL BE STORED IN A SAFE DRY LOCATION. DAMAGED OR BROKEN CEILING

TILES SHALL BE REPLACED. DRYWALL CEILINGS SHALL BE PATCHED,

PREPPED AND NEW FINISH APPLIED TO MATCH EXISTING.

G. REFER TO FINISHES SHEETS AND SPECIFICATIONS FOR INFORMATION ON

GYPSUM BOARD PAINT FINISH.

H. WHERE NEW CEILINGS ARE INSTALLED AND SPRINKLERS ARE EXISTING TO

REMAIN, SPRINKLERS SHALL BE ADJUSTED TO NEW CEILING HEIGHTS, WHEN

APPLICABLE.

REFLECTED CEILING GENERAL NOTES

A

TYPE GRAPHIC DESCRIPTION

B

2x2 ACOUSTICAL CEILING TILE (AT-1 & AT-2).

REFER TO ROOM FINISH SCHEDULE

GYPSUM BOARD CEILING. CEILING PAINT.

REFLECTED CEILING PLAN TYPE LEGEND

EXISTING CEILING / NO CEILING

1. INSTALL 90 DEGREE CORNER DOME MIRROR.

REFLECTED CEILING NOTES #

1 HR FIRE RATED

SMOKE PARTITION

WALL RATING LEGEND

EXISTING WALL UPGRADED TO 1

HOUR FIRE RATED

EXISTING 2 HOUR FIRE RATED

PROJECT LOCATION:

FIRST FLOOR

BUILDING 111 KEY PLAN

N

SHADE INDICATES

AREA NOT IN SCOPE,

TYP.

ARCHITECTURAL SYMBOLS LEGEND

NO NEW ARCHITECTURAL WORK TO TAKE PLACE IN

THIS AREA. REFER TO MEP DRAWINGS FOR

EXTENT OF WORK.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.1

A v d c h ri s te n s e n M

N F

X

.r v t

/6 /2

:4

:4

P

M

AE110.B

ENLARGED REFLECTED CEILING PLAN - AREA

B

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

CONSTRUCT WOMEN'S CLINIC

5000 W. NATIONAL AVE, MILWAUKEE, WI 53295

695-19-132

09/07/2022 JF DMC

100% BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"AE110.B

1 ENLARGED REFLECTED CEILNG PLAN - AREA B

N

GENERAL NOTE:

ALL WORK TO BE COMPLETED SIMULTANEOUSLY (DEMOLITION - INCLUDING MEP, HAZMAT REMOVAL, NEW CONSTRUCTION - INCLUDING MEP) BY PHASE TO REDUCE DISRUPTION TO OCCUPIED SPACES. MULTIPLE MOBILIZATIONS ARE NOT PERMITTED WITHOUT COR APPROVAL. REFER TO SHEET GC101 AND MEP

Z

6'

3/ 4"

1'

/4

1'

1/ 4"

10' - 4"

S3A.TB2Gi

F3A.TBi

F3A.MRi

3' - 0" 1' - 5 1/2" 3' - 6" 2' - 0"

1' - 6" 2' - 0"

LOCATION OF PNEUMATIC

TUBE STATION

PASS THRU CABINET

1' - 6" 65 SF

PATIENT TOILET

F3A.Gi ø 5' - 6"

S3A.GTBi

S3A.Gi

INSTALL SOUND BATT IN

EXISTING WALL PRIOR TO

NEW FINISH

T

S3A.2Gi

F3A.Gi

F3A.TBi

S3A.GTBi

F0D.GF0D.GF0D.G

S3A.Gi S3A.1Fi

S3A.GTBi

9'

/2

7' - 6" 1' - 2" 7' - 9 1/4"

1400A

F3D.G

6'

/4

/4

F3A.Gi

A

LI

G N

3'

1"

82 SF

LACTATION

68 SF

FAMILY TOILET

1400A

S3A.TB2Gi F3A.TBi F3A.2Gi ø 5' - 6" ø 5' - 6"

1'

1'

S3A.2Gi

F3A.MRi

S3A.1Fi

ALIGN

B

T

6'

/4

1'

/4

7'

1/ 4"

9' - 7 1/2"

1' - 6"

1' - 6"

2' - 0" 3' - 8" 3' - 3"

F3A.TBi

S3B.SPi

S3B.SPi

S3B.SPi

S3A.2Gi S3B.SPi F3A.Gi

F3D.G

F0D.GF0D.GF0D.G

S3A.2Gi1450

1452A

A

B 6"

6" ø 5' - 6"

S3A.1Fi

S3A.GTBi

S3A.TB2Gi

S3B.SPi

EQ EQ

52 SF

SOILED HOLDING

67 SF

PATIENT TOILET

1452A

173 SF

PROCEDURE

1452F3A.Gi

S3A.1FTBiS3A.1Fi

X U

1' - 8" 9' - 11 1/2" 7' - 9 1/4"

3' - 0"

3' - 0 1/2"

4'

/2

C

LE

A R

6'

ALIGN

8' - 5 1/4" 3' - 10 1/4"

F0D.G

S3A.Gi

F3D.G

S3A.Gi F3D.G

F0D.GF0D.G

A

C1

4'

/2

ALIGN

S3A.Gi

1'

F3D.G

F3D.G

S3A.2Gi S3A.2Gi

30 SF

LINEN CLOSET

8 SF

WHEELCHAIR

STORAGE

1400B

141 SF

FAMILY WAITING

1400C

208 SF

CHECK-IN

89 SF

INTAKE

118 SF

CORRIDOR

C1C01

43 SF

INTAKE - ALCOVE

S3A.2Gi

S3A.MRi

S3A.G

S3A.2Gi

S3A.GS3A.G

F3D.G

F0D.G

F3D.G

F3D.G

F3D.G

F3A.Gi

F0D.G

S3A.G

F3A.Gi

U

F0D.G

F0D.G

F3A.Gi

F0D.G

F3A.Gi

F3A.Gi

FRAMING TO ALIGN TO

FACE OF COLUMN - TYP

ZAA

ALIGN WALL FINISH

TO COUNTER

F3A.Gi

F3D.G

F3D.G

S3A.1FF0D.GS3A.1F

S3A.Gi

ALIGN STUD TO

FACE OF COLUMN

U ST

13' - 1" 6' - 9 1/2"

9' - 5 3/4" 6' - 1 3/4" 5' - 5"

C

LE

A R

5'

C

LE

A R

4'

/4

6'

/2

1'

1' - 6" 5' - 10" 3' - 6"

1' - 10 1/4"

6'

C

LE

A R

O P

E N

IN

G

4'

1'

F0D.TB

F3A.TBi

S3A.GTBi

F3A.TBiF3A.TBi

F3A.TBi

F3A.TBi

1'

/4

ALIGN

ALIGN STUD TO FACE

OF EXISTING WALL

F0D.G

F0D.G

F0D.G

1' - 6" 5' - 10"

S3B.SPi

S3A.GTBi

F3A.Gi

F3D.TB

S3A.GTBi S3A.GTBi

F0D.G

F0D.G F0D.G S3A.G ø 5' - 6" ø 5' - 6" ø 5' - 6" ø 5' - 6"

CLEAR

5' - 0"

F0D.TB

S3A.GTBi

S3A.GTBi

S3A.GTBi

F0D.TB

F3D.TB

S3A.GTBi

F3A.Gi

F3D.G

F0D.G

F0D.G

F3D.G

S3A.GTBiS3A.GTBi

6'

ALIGN

EQ EQ

1' - 6" 3' - 9" 1' - 6"

1' - 6" 2' - 8 3/4" 1' - 6"

ALIGN STUD TO

FACE OF COLUMN

F3D.G

C

LE

A R

5'

209 SF

MENS TOILET

243 SF

WOMENS TOILET

4' - 0"

PROVIDE BLOCKING FOR

WALL MOUNTED DIRECTORY

DISPLAY

X

F0D.G

S3A.Gi

F3D.G

S3A.GiF0D.G

F0D.G

ALIGN WALL FINISH

FLUSH TO COUNTER

FRAMING TO

ALIGN TO FACE

OF COLUMN

FIRE RATING UL DESIGN

MIN STC

RATING

LINE OF STRUCTURE ABOVE

LINE OF CEILING

LINE OF STRUCTURE BELOW

PLAN

2 LAYERS OF 5/8" TYPE X GYP BD

BEAD OF CONT. SEALANT

EXISTING WALL FRAMING

TO REMAIN

CEILING

HOLD GYPSUM BACK FROM DECK FOR

DEFLECTION

FILL FLUTES OF DECK WITH FIRE SAFING

AT FIRE RATED WALLS

INSTALL SOUND BATT INSULATION

38V4971 HR

EXISTING WALL FINISH TO

REMAIN

PROJECT SIDENOT IN SCOPE SIDE

LINE OF DUCTWORK ABOVE

LINE OF CEILING

3 5/8" STEEL STUD CORNER BRACING

CEILING - REFER TO RCP

DEEP LEG SLIP TRACK AT DECK

HOLD FRAMING AND GYPSUM BACK FROM DUCT

FOAM ISOLATOR

M

IN

1/

2"

WALL TYPE - REFER TO

SHEET AE100.A

PROVIDE SOUND BATT

INSULATION LAY-IN AT DUCT

LINE OF DUCTWORK ABOVE

LINE OF CEILING

3 5/8" STEEL STUD CORNER BRACING

1 HR FIRE RATED CEILING - REFER TO RCP

DEEP LEG SLIP TRACK AT DECK

HOLD FRAMING AND GYPSUM BACK FROM DUCT

FOAM ISOLATOR

M

IN

1/

2"

1 HR FIRE RATED WALL -

REFER TO SHEET AE100.A

PROVIDE SOUND BATT

INSULATION LAY-IN AT DUCT

MINERAL WOOD INSULATION

3 LAYERS OF 5/8" TYPE X

GYPSUM BOARD

3 5/8" METAL STUD FRAMING

w/ TYPE S FASTENERS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.1

A v d c h ri s te n s e n M

N F

X

.r v t

/6 /2

:4

:5

P

M

AE400

ENLARGED ARCHITECTURAL PLANS AND

DETAILS

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

CONSTRUCT WOMEN'S CLINIC

5000 W. NATIONAL AVE, MILWAUKEE, WI 53295

695-19-132

09/07/2022 JF DMC

100% BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 3/8" = 1'-0"AE400

2 PATIENT TOILET (1438)

SCALE: 3/8" = 1'-0"AE400

1 LACTATION (1407) & FAMILY TOILET (1400A)

SCALE: 3/8" = 1'-0"AE400

3 SOILED HOLDING (1450) & PATIENT TOILET (1452A)

SCALE: 3/8" = 1'-0"AE400

4 WHEELCHAIR STORAGE (1400B), LINEN CLOSET (1433), & INTAKE - ALCOVE (1434)

SCALE: 1/2" = 1'-0"AE400

6 COLUMN DETAIL @ EXAM

SCALE: 1/2" = 1'-0"AE400

7 COLUMN DETAIL @ CONFERENCE / BREAK

SCALE: 3/8" = 1'-0"AE400

5 PUBLIC RESTROOMS (1409 & 1410)

SCALE: 1/2" = 1'-0"AE400

8 COLUMN DETAIL

NOTE:

PROVIDE IN-WALL BLOCKING AT ALL WALL MOUNTED ACCESSORIES.

GENERAL NOTE:

ALL WORK TO BE COMPLETED SIMULTANEOUSLY (DEMOLITION - INCLUDING MEP, HAZMAT REMOVAL, NEW CONSTRUCTION - INCLUDING MEP) BY PHASE TO REDUCE DISRUPTION TO OCCUPIED SPACES. MULTIPLE MOBILIZATIONS ARE NOT PERMITTED WITHOUT COR APPROVAL. REFER TO SHEET GC101 AND MEP

DRAWINGS FOR PHASING PLAN.

SCALE: 1 1/2" = 1'-0"AE400

9 EXISTING WALL RATING UPGRADE DETAIL

SCALE: 1 1/2" = 1'-0"AE400

10 TOP OF WALL DETAIL @ EXISTING DUCT

SCALE: 1 1/2" = 1'-0"AE400

11 TOP OF FIRE RATED WALL DETAIL (UL I504) @ EXISTING DUCT

C

OS

OS

OS

OS

U T

2' - 11 1/4"

A 9' - 0" B 8' - 0"

B 7'

A 9'

0"

B 7'

4'

/4

4' - 11 1/2"

82 SF

LACTATION

360 SF

RECEPTION /

WAITING

1403EC

ELECTRICAL

208 SF

CHECK-IN

90 SF

INTAKE

30 SF

LINEN CLOSET

68 SF

FAMILY TOILET

1400A

A 9' - 0"

A 9' - 0"

A 9' - 0"

118 SF

CORRIDOR

C1C01

A 9' - 0"

4' - 4"

3'

LOCATION OF SLAB INFILL ON SECOND

FLOOR, CONTRACTOR TO VERIFY

8' - 6"

1'

5/

8"

10 3/4"

1'

6" 5'

6"

4' - 7"

B 8'

6"

A 9'

0"

A

LI

G N

AE110

SP SP

SP

SP

MATCH FLOORING TO

BULKHEAD EXTENSION

AE401

AE401

6'

SIM

1' - 0"

AE110

AE110

DRILL AND EPOXY-GROUT 3/4"

DIA. THREADED ROD INTO

EXISTING 6" SLAB W/ 4" MIN.

EMBED, TYP. (VERIFY FIELD

CONDITIONS. NOISE CONTROL

PER SPEC)

PROVIDE 45 DEGREE KICKER

SUPPORT INTO SLAB.

ALTERNATE DIRECTION

BETWEEN SUPPORTS AT

TYPICAL SPACING

ANGLE BRACKET FOR

3/4" DIA. THREADED ROD

CONNECTION. DOUBLE

NUT AND WASHER TO

LEVEL

3/4" DIA. HANGING ROD AT 24" O.C.

TYP. SPACING. PROVIDE COUPLER

TO CONCRETE ANCHOR

ANGLE BRACKET FOR

3/4" DIA. THREADED ROD

CONNECTION. DOUBLE

NUT AND WASHER TO

LEVEL

DOUBLE NUT AND

WASHER -LEVELED

CONNECTION TO LIFT

HARDWARE (SEE

MANUF.)

.0

2'-0" O.C. TYP. CONFIRM WITH MANUF. FOR APPROVED SPACING

P1001 OR SIMILAR, SLOTTED

CHANNEL FRAMING, MATCH TO

CEILING, SEE SPEC 050430. TYP.

CEILING

REFER TO RCP

1/ 2"

3/

4"

SUPPORT PENDANT , ALIGN

BOTTOM TO CEILING

TRAVERSE RAIL

LIFT MOTOR CARRIAGE

LIFT MOTOR CARRIAGE

STRAP

SLINGBAR

TRAVERSE RAIL

SUPPORT PENDANT

CEILING

REFER TO RCP

U

AE401

AE401

1' - 4 1/2"

1' - 10"

A

LI

G N

1' - 8 3/4"

4'

/2

E Q

E Q

AE401

AE401

AE401

AE401

D

C C

GL1

GL1 GL1A

S

S C

H E

D U

LE

D

2'

A S

S C

H E

D U

LE

D

3'

KNEE

SPACE

CONCEALED BRACKETS,

4'-0" O.C. MAX

BULKHEAD

AE401

AE401

DCC

PROVIDE LOCKS ON

SLIDING WINDOWS

GL1 GL1

GL1

CONCEALED BRACKETS,

4'-0" O.C. MAX

2'

BULKHEAD

3' - 4"

5'

2'

BRACKET BEYOND

RESILIENT BASE,

BOTH SIDES

SOLID SURFACE OVER 3/4"

MDF SUBSTRATE. ALL

EXPOSED SURFACES SHALL

BE SOLID SURFACE WITH

RADIUS CORNERS.

GROMMET LOCATION.

COORDINATE LOCATION

WITH OWNER

CONTINUOUS WOOD

BLOCKING

PL-2PL-2

1' - 4"

D

3 5/8" METAL STUD FRAMING AT 16"

O.C. - ANCHOR TO STRUCTURE

ABOVE

5/8" GYPSUM BOARD CEILING

CONTINUE GYPSUM BOARD AND

SOUND BATT INSULATION TO DECK

WALL BEYOND

AE600

AE600

5/8" TYPE X GYPSUM

BOARD

3 5/8" METAL STUD FRAMING w/

SOUND BATT INSULATION

BRACKET BEYOND

RESILIENT BASE,

BOTH SIDES

2' - 6"

1' - 0"

5 3/4" 6 1/2"

1 1/2"

1'

2'

4'

3'

SOLID SURFACE OVER 3/4"

MDF SUBSTRATE. ALL

EXPOSED SURFACES SHALL

BE SOLID SURFACE WITH

RADIUS CORNERS.

GROMMET LOCATION.

COORDINATE LOCATION

WITH OWNER

CONTINUOUS WOOD

BLOCKING

1/2" SOLID SURFACE

TRANSACTION TOP WITH

RADIUS CORNERS OVER 3/4"

MDF SUBSTRATE

PL-2

PL-3

PL-2

PL-3

CENTER WINDOW TO WALL

FRAMING

3 5/8" METAL STUD FRAMING AT 16"

O.C. - ANCHOR TO STRUCTURE

ABOVE

C

5/8" GYPSUM BOARD CEILING

CONTINUE GYPSUM BOARD AND

SOUND BATT INSULATION TO DECK

AE600

AE600

SIM

TS-5

5/8" TYPE X GYPSUM

BOARD

3 5/8" METAL STUD FRAMING w/

SOUND BATT INSULATION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.1

A v d c h ri s te n s e n M

N F

X

.r v t

/6 /2

:4

:5

P

M

AE401

ENLARGED PLANS AND REFLECTED CEILING

PLAN

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

CONSTRUCT WOMEN'S CLINIC

5000 W. NATIONAL AVE, MILWAUKEE, WI 53295

695-19-132

09/07/2022 JF DMC

100% BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 3/8" = 1'-0"AE401

1 RECEPTION / WAITING RCP

SCALE: 1 1/2" = 1'-0"AE401

2 PATIENT LIFT MOUNTING DETAIL

SCALE: 1 1/2" = 1'-0"AE401

3 PATIENT LIFT SLINGBAR DETAIL

SCALE: 3/8" = 1'-0"AE401

4 CHECK-IN (1432)

GENERAL NOTE:

ALL WORK TO BE COMPLETED SIMULTANEOUSLY (DEMOLITION - INCLUDING MEP, HAZMAT REMOVAL, NEW CONSTRUCTION - INCLUDING MEP) BY PHASE TO REDUCE DISRUPTION TO OCCUPIED SPACES. MULTIPLE MOBILIZATIONS ARE NOT PERMITTED WITHOUT COR APPROVAL. REFER TO SHEET GC101 AND MEP

DRAWINGS FOR PHASING PLAN.

SCALE: 3/8" = 1'-0"AE401

5 CHECK-IN WINDOW ELEVATION - PATIENT SIDE

SCALE: 3/8" = 1'-0"AE401

6 CHECK-IN WINDOW ELEVATION - STAFF SIDE

SCALE: 1" = 1'-0"AE401

7 CHECK-IN COUNTER SECTION @ ACCESSIBLE TOP

SCALE: 1" = 1'-0"AE401

8 CHECK-IN COUNTER SECTION @ STANDING HEIGHT

HOLLOW METAL FRAME,

RE: DOOR SCHEDULE

WALL TYPE,

RE: PLANS

DOUBLE STUD FRAMING

SEALANT BOTH SIDES

HOLLOW METAL FRAME,

RE: DOOR SCHEDULE

WALL TYPE,

RE: PLANS

FRAMING STUD HEADER

SEALANT BOTH SIDES

1. PROVIDE CARD READER AND ASSOCIATED ACCESSORIES. PROVIDE

ELECTRIC STRIKE AND OR ELECTRIFIED EXIT DEVICES AS REQUIRED. REFER

TO ENGINEERING DRAWINGS AND ACCESS CONTROL FOR ADDITIONAL

INFORMATION.

2. PROVIDE AUTOMATIC DOOR OPENER AND ASSOCIATED ACCESSORIES.

REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION.

3. PROVIDE HOLD OPENS.

4. PROVIDE KICKPLATE.

REFER TO DETAILS INDICATED FOR HEAD, JAMB, AND SILL CONDITIONS.

VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION.

A. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL HARDWARE

REQUIREMENTS BETWEEN HARDWARE SUPPLIERS, ACCESS CONTROL

VENDOR, AND ANY OTHER TRADES THAT ARE INVOLVED. REQUIRED POWER

SUPPLIES AND AUXILIARY COMPONENTS THAT IS REQUIRED TO MAKE A

HARDWARE SET WORK BETWEEN ACCESS CONTROL AND HARDWARE SHALL

BE PROVIDED.

B. ALL HOLLOW METAL DOORS AND FRAMES SHALL BE FACTORY PRIMED AND

RECEIVE PAINT FINISH ON SITE. REFER TO FINISH SCHEDULE FOR HOLLOW

METAL PAINT COLOR.

C. PROVIDE SEALANT AROUND PERIMETER OF DOOR/ WINDOW FRAME

ADJACENT TO WALL AND FLOOR CONSTRUCTION, BOTH SIDES.

D. LOCATE HINGE SIDE OF DOOR 6" OFF OF ADJACENT WALL UNLESS

OTHERWISE INDICATED ON FLOOR PLAN.

E. MAINTAIN ADA CLEARANCE AROUND DOORS AND REFER ANY

DISCREPANCIES DUE TO COR AND ARCHITECT FOR CLARIFICATION.

F. RATED FRAMES, DOORS AND GLAZING SHALL BE UL LABELED IN A VISIBLE

LOCATION.

G. REFER TO DOOR/ WINDOW AND FRAME LEGEND FOR REFERENCE TO

TYPICAL HEAD, JAMB AND SILL DETAILS.

H. ALL HOLLOW METAL JAMBS TO BE PREPARED FOR ACCESS CONTROL AND

SECURITY HARDWARE. REFER TO ENGINEERING DRAWINGS FOR

ADDITIONAL INFORMATION.

I. REFER TO SPECIFICATIONS AND ENGINEERING DRAWINGS FOR ADDITIONAL

HARDWARE INFORMATION.

J. COORDINATE POWER AND DATA REQUIREMENTS AT DESIGNATED DOOR

OPENINGS WITH ENGINEERING DRAWINGS.

DOOR AND FRAME GENERAL NOTES

DOOR SCHEDULE COMMENTS

MG1 TEMPERED FLOAT GLASS

GL1 CLEAR FLOAT GLASS

FG1 1 HR FIRE RATED GLASS

RP1 RESIN PANEL (REFER TO FINISHES)

GLAZING TYPE LEGEND

S2

AS SCHEDULED 2" TYP

7'

A S

S C

H E

D U

LE

D

AS SCHEDULED AS SCHEDULED

A S

S C

H E

D U

LE

D

4" 8"

A F

F

3'

2'

AS SCHEDULED

A S

S C

H E

D U

LE

D

8" X 8"

A F

F

3'

2'

AE600

AE600

AE600

AE600

DOOR AND FRAME TYPE LEGEND

FL NL HG

T

DOOR TYPE ABBREVIATIONS

FL FLUSH

NL NARROW LIGHT

HG HALF GLASS

FG FULL GLASS

DOOR MATERIAL ABBREVIATIONS

HM HOLLOW METAL

WD WOOD

FRAME TYPE ABBREVIATIONS

S2 SINGLE / 2" HEAD

D2 DOUBLE / 2" HEAD

L2 SINGLE w/ SIDELIGHT / 2" HEAD

ES EXAM SLIDING / HEAD SIZE VARY PER MFR.

R2 SINGLE, RESCUE / 2" HEAD

E2 DOUBLE EGRESS / 2" HEAD

SH SECURITY SHUTTER

SE STOREFRONT

FRAME MATERIAL ABBREVIATIONS

AL ALUMINUM

HM HOLLOW METAL

WD WOOD

R2

AS SCHEDULED 2" TYP

RESCUE FRAME

A S

S C

H E

D U

LE

D

AS SCHEDULED

2"

V A

R

IE

S P

E R

M F

R

SLIDINGES

VALANCE WIDTH

AE600

AE600

AE600

A S

S C

H E

D U

LE

D

AS SCHEDULED

FG

T

SH

A S

S C

H E

D U

LE

D

AS SCHEDULED

STOREFRONTSE

*REFER TO ELEVATION

S E

E E

LE

V

A T

IO

N

SEE ELEVATION

CONCEALED SILL GUIDE

SILL GUIDE (BEYOND)

SLIDING DOOR WALL (BEYOND)

FINISH FLOOR

WALL (BEYOND)

TRACK SYSTEM

DOUBLE 6" METAL

STUD HEADER

SLIDING DOOR

HOLLOW METAL FRAME,

RE: DOOR SCHEDULE

WALL TYPE,

RE: PLANS

SEALANT BOTH SIDES

2"

FRAMING STUD HEADER

RESCUE DOOR HOLLOW METAL

DOOR FRAME

SEALANT - BOTH SIDES

WALL TYPE,

RE: PLANS

RESCUE STOP/ STRIKE

CORRIDOR

SIDE

TOILET

SIDE

2"

DOUBLE STUD FRAMING

RESCUE DOOR HOLLOW METAL

DOOR FRAME

SEALANT - BOTH SIDES

WALL TYPE,

RE: PLANS

RESCUE STOP/ STRIKE

TOILET SIDE

CORRIDOR SIDE

SCHEDULED GLAZING

ALUMINUM STOREFRONT

SEALANT, BOTH SIDES

SHIM

WALL,

RE: FLOOR PLANS

4"

1 3/4"

WRAP GYPSUM

AROUND JAMB

SCHEDULED GLAZING

ALUMINUM STOREFRONT

SEALANT, BOTH SIDES

SHIM

WALL,

RE: FLOOR PLANS

4"

3/

4"

6" METAL STUD BOX HEADER

WRAP GYPSUM

AROUND HEADER

SCHEDULED GLAZING

ALUMINUM STOREFRONT

BACKER ROD AND SEALANT

SHIM

EXISTING FLOOR

CONSTRUCTION

4"

3/

4"

EPDM GASKET BOTH SIDES

MIN. 16 GA STUD AT JAMBS &

16" O.C. FOR ENTIRE LENGTH

OF VALANCE

EDGE GASKET

SILL GUIDE

RE: DOOR SCHEDULE

DOOR LEAF: FRAME OPENING + 7"

ROOM SIDE

OUTSIDE

FRAME OPENING

VALANCE AND END CAP ABOVE

STILE SUPPORT BRACKET

STILE POCKET

BACK TO BACK 1" LADDER PULLS

VALANCE: WIDTH X2 + 10"

FIRE RETARDANT

TREATED BLOCKING

SCHEDULED ALUMINUM

STOREFRONT DOOR

ALUMINUM STOREFRONT

JAMB

SCHEDULED GLAZING

SHIM

WALL

RE: FLOOR PLAN

BACKER ROD

AND SEALANT

4"

1 3/4"

2 1/4"

CONCEALED HINGE

WRAP GYPSUM

AROUND JAMB

8'

7'

1'

/4

3/

4" T

Y P

3' - 7 3/4" 2' - 2 1/2" 1 3/4" TYP

6' - 0"

C1

RP1

RP1MG1

AE600

AE600

AE600

AE600

MG1

FG1

3' - 8 1/2" 1' - 10 1/4" TYP

2 1/2"

5' - 9"

FG1

FG1

FG1

7'

CENTER MULLION

w/ DOOR

AE600

SIM

AE600

SIM

AE600

SIM

TRANSLUCENT

FILM

ANODIZED ALUMINUM

TRANSACTION SLIDING

WINDOW UNIT

ROLLER TRACK

SIM, AS REQUIRED

SEALANT, BOTH SIDES

5/8" GYP BOARD BULKHEAD

5/8" GYP BOARD TO DECK

ABOVE

SOUND BATT INSULATION

6" METAL STUD BOX HEADER

5"

STAFF SIDE

SLIDE STOP

METAL TRACK

SLIDING PANEL

POSITIVE

LATCH LOCK

FIXED PANEL

ANODIZED ALUMINUM TRANSACTION

SLIDING WINDOW UNIT

SEALANT, BOTH SIDES

DOUBLE STUD AT JAMBS

WALL TYPE, REFER TO PLANS

5"

EQ EQ

CENTER WINDOW TO

WALL FRAMING

ANODIZED ALUMINUM

TRANSACTION SLIDING

WINDOW UNIT

SOLID SURFACE COUNTERTOP

5/8" GYPSUM BOARD

SOUND BATT INSULATION

SEALANT, BOTH SIDES

3/4" MDF

SUPPORT BRACKET

WINDOW TYPE LEGEND

C - SLIDING TRANSACTION D - SLIDING TRANSACTION

A .F

.F

3'

A S

S C

H E

D U

LE

D

AS SCHEDULED

A .F

.F

2'

A S

S C

H E

D U

LE

D

EQ EQ

GL1

GL1

EQ EQ

AS SCHEDULED

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.1

A v d c h ri s te n s e n M

N F

X

.r v t

/6 /2

:4

:0

P

M

AE600

DOOR SCHEDULE

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

CONSTRUCT WOMEN'S CLINIC

5000 W. NATIONAL AVE, MILWAUKEE, WI 53295

695-19-132

09/07/2022 JF DMC

100% BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 3" = 1'-0"AE600

8 DOOR JAMB DETAIL, HM

SCALE: 3" = 1'-0"AE600

9 DOOR HEAD DETAIL, HM

SCALE: 3" = 1'-0"AE600

1 SLIDING DOOR - SILL

SCALE: 3" = 1'-0"AE600

3 SLIDING DOOR - HEAD

DOOR SCHEDULE

DOOR

NUMBER

ROOM DIMENSIONS DOOR FRAME DETAILS FIRE

RATING

GLAZING

TYPE

HARDWARE

SET COMMENTSNUMBER NAME WIDTH HEIGHT THICKNESS TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILL

1400 1400 RECEPTION / WAITING 3' - 6" 6' - 9 1/2" 1 3/4" FG AL CLEAR SE AL CLEAR 6/AE600 5/AE600 4/AE600 45 FG1 20.0 1, 2

1400A 1400A FAMILY TOILET 3' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 10.0

1407 1407 LACTATION 3' - 6" 7' - 0" 1 3/4" FL HM STAIN S2 HM PAINT 9/AE600 8/AE600 - 45 11.0

1409 1409 MENS TOILET 3' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 25.0 2

1410 1410 WOMENS TOILET 3' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 25.0 2

1432 1432 CHECK-IN 3' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 6.0

1433 1433 LINEN CLOSET 5' - 0" 7' - 0" 1 3/4" FL WD PAINT S2 HM PAINT 9/AE600 8/AE600 - 0 2.0

1435 1435 INTAKE 3' - 6" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 13.0

1436 1436 INTAKE 3' - 6" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 0 13.0

1437 1437 INTAKE 3' - 6" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 13.0

1438 1438 PATIENT TOILET 3' - 6" 7' - 0" 1 3/4" FL WD STAIN R2 HM PAINT 11/AE600 10/AE600 - 0 12.0

1439 1439 LAB 3' - 6" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 8.0

1440 1440 CONSULT 3' - 6" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 18.0

1441 1441 EQUIPMENT 3' - 0" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 19.0

1442 1442 CLEAN STORAGE 3' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 3.0

1443 1443 EXAM 3' - 6" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 18.0

1444 1444 CONSULT 3' - 6" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 18.0

1445 1445 EXAM 3' - 6" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 18.0

1446 1446 MEDS 3' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 24.0 1

1447 1447 EXAM 3' - 6" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 18.0

1448 1448 PROCEDURE 3' - 6" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 18.0

1448A 1448A PATIENT TOILET 3' - 6" 7' - 0" 1 3/4" FL WD STAIN R2 HM PAINT 11/AE600 10/AE600 - 0 12.0

1449 1449 EXAM 3' - 6" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 18.0

1450 1450 SOILED HOLDING 3' - 0" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 19.0

1450A 1450 SOILED HOLDING 3' - 0" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 19.0

1450B 1450 SOILED HOLDING 3' - 0" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 19.0

1451 1451 EXAM 3' - 6" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 18.0

1452 1452 PROCEDURE 3' - 6" 7' - 0" 1 3/4" FL WD STAIN ES HM PAINT 3/AE600 2/AE600 1/AE600 0 18.0

1452A 1452A PATIENT TOILET 3' - 6" 7' - 0" 1 3/4" FL WD STAIN R2 HM PAINT 11/AE600 10/AE600 - 0 12.0

1453 1453 LOCKER ROOM 3' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 15.0

1454 1454 CONFERENCE / BREAK 3' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 14.0

1455 1455 STAFF TOILET 3' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 10.0

1457 1457 RESIDENT WORKROOM 3' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 5.0

1458 1458 WHEELCHAIR WASH 3' - 6" 7' - 0" 1 3/4" FL HM PAINT S2 HM PAINT 9/AE600 8/AE600 - 45 9.0 4

1459 1459 STORAGE 3' - 0" 7' - 0" 1 3/4" FL HM STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 1.0

1460 1460 HAC 3' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 4.0

1461 1461 ELECTRICAL 3' - 0" 7' - 0" 1 3/4" FL HM STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 3.0

1462 C1C11 CORRIDOR 3' - 0" 7' - 0" 1 3/4" FL HM PAINT S2 HM PAINT 9/AE600 8/AE600 0 3.0

1463 1463 DRY STORAGE 3' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 0 3.0 4

1464 1464 CANISTER STORAGE 5' - 0" 7' - 0" 1 3/4" FL WD STAIN S2 HM PAINT 9/AE600 8/AE600 0 2.0 4

1465 1465 VCS OFFICE 3' - 0" 7' - 0" 1 3/4" NL HM STAIN S2 HM PAINT 9/AE600 8/AE600 - 0 GL1 6.0

1465A 1465A VCS CHIEF OFFICE 3' - 0" 7' - 0" 1 3/4" NL WD STAIN S2 HM PAINT 9/AE600 8/AE600 - 0…