This single source justification document identifies door hardware products required for a women's clinic construction project at the Department of Veterans Affairs Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin. The medical center requires Sargent 11 Series T-zone cylindrical locksets, Sargent 8200 series Mortise Locksets with Medeco 7-pin interchangeable cylindrical cores, LCN Closers, Von Duprin exit devices, and Hager hinges to be consistent with facility standards for quality, maintenance of replacement parts, staff training requirements, and existing keying systems. Use of alternate brands would necessitate additional costs to maintain a separate locking system and stock replacement parts. Market research found other hardware products to be inferior and incompatible. The contracting officer certified the single source purchase in accordance with FAR 13.106-1. The related federal contract opportunity is solicitation number 36C25223B0004 for the construction of the women's clinic under project number 695-19-132 through the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Single Source Justification 695-19-132 Project 695-19-132 - Construct Women’s Clinic
DEPARTMENT OF VETERANS AFFAIRS
Justification for Single Source Awards IAW FAR 13.106-1 For
Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K)
Acquisition Plan Action ID: 36C252-23-AP-0134
1. Contracting Activity: Department of Veterans Affairs, VISN 12, Zablocki Medical Center
NCO 12, 115 South 84th Street, Milwaukee, WI 53214. Requesting Activity: Department of Veterans Affairs, VISN 12, Clement J. Zablocki VA Medical Center, 5000 W. National Avenue, Milwaukee WI 53295. Purchase Request (2237) number: NCO 12 Construction Team - 695-19-132 Construct Women’s Clinic
2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount:
These products, Sargent 11 Series T-zone cylindrical lockset and Sargent 8200 series Mortise Locksets with Medeco 7-pin interchangeable cylindrical cores, LCN Closers (Mechanical, Electronic Hold-Open, Electromagnetic), Von Duprin Exit Devices and Hager Hinges are facility standards. It would be extremely cumbersome and expensive to maintain a completely separate locking system.
Estimated Cost $14,700.
3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:
The medical center requires all construction incorporate the Sargent Locksets and Medeco keying system, LCN Closers (Mechanical, Electronic Hold-Open, Electromagnetic), Von Duprin exit devices and Hager hinges because experience has found out that “approved equals” are not at all equal in quality. It is also important to note that maintaining bench stock for the parts and keying components of an entirely different locking system and hardware sets would be expensive and time-consuming. Use of another brand would require duplicating efforts in training and double the stock on hand for replacement parts. These items are competitively priced and are widely available.
4. Description of market research conducted and results or statement why it was not conducted:
We have conducted research into other hardware and have found that it is inferior and not compatible with our standard. The other products on the market would require additional cost to maintain within the facility.
5. Contracting Officer's Certification: Purchase is approved in accordance with FAR13.106-1(b). I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.
Stacy Hoover, Contracting Officer https://www.acquisition.gov/?q=/browse/far/13 https://acquisition.gov/far/current/html/Subpart%2013_1.html#wp1125466