This is a Request for Information (RFI) response regarding Project 610-20-103 for the renovation of Building 16 at the Department of Veterans Affairs facility in Marion, Indiana. The RFI (numbered NH04) dated December 11, 2024, seeks clarification about wall type P-9 construction specifications, specifically regarding metal stud spacing, foam insulation requirements, and R-19 batt insulation installation.

The response from Viridian Architectural Design, Inc., dated December 24, 2024, indicates that P-9 is to be a field application based on variable conditions. They clarify that the 1-1/2" spray foam insulation and R-19 batt insulation may overlap in some locations to ensure a complete insulation barrier, and the spray foam insulation should be acceptable to the owner. The RFI was submitted by Don Jungst from Nora/Hagerman in Fishers, IN. The project is part of a larger renovation to house the VA Northern Indiana Health Care System's Executive Leadership Team and administrative departments.

View the file

Other files for this federal contract opportunity

Other files attached to Renovate Building 16, 610-20-103, newest first.
File Type Posted
36C25025B0005 - Provision and Clauses Section 1.pdf PDF
36C25025B0005 0008.pdf PDF
36C25025B0005 0007.pdf PDF
36C25025B0005 0006.pdf PDF
36C25025B0005 0005.pdf PDF
Amend 4.pdf PDF
RFI 20.pdf PDF
RFI 36.pdf PDF
RFI 19.pdf PDF
RFI 1.pdf PDF
36C25025B0005 0003.pdf PDF
RFI 35.pdf PDF
RFI 32.pdf PDF
RFI 33.pdf PDF
RFI 37.pdf PDF
RFI 28 - RESPONSE - VADI - 2025.01.23.pdf PDF
Amendment 2 B0005.pdf PDF
RFI 20 - jah response - 2025.01.30.pdf PDF
RFI 26 - RESPONSE - VADI - 2025.01.23.pdf PDF
RFI 34 - jah response - 2025.01.30.pdf PDF
RFI 5 - RESPONSE - VA - 2025.01.08.pdf PDF
RFI 31 - jah response - 2025.01.30.pdf PDF
RFI 43.pdf PDF
RFI 24 - RESPONSE - VADI - 2025.01.23.pdf PDF
RFI 30 - RESPONSE - VADI - 2025.01.23.pdf PDF
RFI 21.pdf PDF
RFI 25.pdf PDF
RFI 29 - RESPONSE - VADI - 2025.01.23.pdf PDF
RFI 7 - RESPONSE - VA - 2025.01.08.pdf PDF
RFI 27 - RESPONSE - VADI - 2025.01.23.pdf PDF
RFI 11 RESPONSE - VA - 2025.01.08.pdf PDF
RFI 4 - RESPONSE - VADI - 2024.12.24.pdf PDF
RFI 15 - RESPONSE - VADI - 2024.12.24.pdf PDF
RFI 14 - RESPONSE - VADI - 2024.12.24.pdf PDF
RFI 2 - RESPONSE - VADI - 2024.12.24.pdf PDF
Marion VA Building 16 Abestos Lead Paint Hazardous Materials Inspection Final Report with attachments.pdf PDF
36C25025B0005 Amend 1.pdf PDF
RFI 5 - RESPONSE - VADI - 2024.12.24.pdf PDF
RFI 6 -RESPONSE - VADI - 2024.12.24.pdf PDF
RFI 16 - RESPONSE - VADI - 2024.12.24.pdf PDF
RFI 12 - RESPONSE - VADI - 2024.12.24.pdf PDF
Reno Bldg 16 Sign In.pdf PDF
Attachment - II - Renovate Bldg 16 - Drawing Set.pdf PDF
Attachment - I - Renovate Bldg 16 - Combined Specifications.pdf PDF
36C25025B0005.pdf PDF
Attachment - IV - RFI Form Solicitaton.docx DOCX document
Attachment - V - Wage Determination.pdf PDF
Attachment - VI - VHA Directive 1192 01.pdf PDF
Attachment - III - Contractor EMR Certification Form.docx DOCX document
36C25025B0005.docx DOCX document
Show all 50

Renovate Building 16, 610-20-103 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR INFORMATION (RFI)

PROJECT NUMBER: 610-20-103 Please ensure that before submitting questions or requests for clarification that you thoroughly read the solicitation, specifications, drawings and other pertinent documents.

When submitting questions on this project the Government requires contractors to specifically identify the specification and/or solicitation section(s) or drawing number(s) in reference to the question or request for clarification submitted. No question or request for clarification will be answered by the Government unless the above requirements are met. Failure to comply may prevent the Government from responding in a timely manner.

PROJECT TITLE: Renovate Building 16

PROJECT LOCATION: Department of Veterans Affairs 1700 E 38th St Marion, IN 46953

TO:

Christopher C. Lee, Contracting Officer

Department of Veterans Affairs

8888 Keystone Dr.

Indianapolis, IN 46202-2884

RFI NO.: NH04 DATE: 12/11/24 SPEC/DWG. REFERENCE:

AS101.1 to AS103.1

REPLY NEEDED BY:

INFORMATION NEEDED:

Wall type P-9 is described as 3-5/8” metal studs…1-1/2” foam insulation between brick wall and metal studs with remaining cavity filled with R-19 batt insulation. Metal stud to stand of existing brick wall 1”.

1. If the foam insulation is 1-1/2” and the studs are 1” off the wall, there will not be 1-1/2” of foam “between the brick and the metal stud. Which is correct 1” standoff or 1-1/2” between?

2. Depending on the answer to 1, there will be a void of either 3-5/8” or 3-1/4” from the face of the foam insulation to the back side of the drywall. RF-19 batt insulation has a nominal thickness of 6-1/2”. Are we to compress the insulation and make it fit? If it is depressed, the R-value will be reduced.

3. There is no specification for foam insulation. Please supply this specification.

REPLY:

P-9 IS TO BE A FIELD APPLICATION BASED ON VARIABLE FIELD CONDITIONS. THE COMBINATION OF 1-1/2”

SPRAY FOAM INSULATION AND R-19 BATT INSULATION IS INTENDED TO PROVIDE AND ENSURE A

COMPLETE INSULATION BARRIER AN IN SOME LOCATIONS MAY OVERLAP.

PROVIDE SPRAY FOAM INSULATION ACCEPTABLE TO THE OWNER.

REPLY FROM: VIRIDIAN ARCHITECTURAL DESIGN, INC.

DATE: DECEMBER 24, 2024

ATTACHMENTS:

COPY TO:

SUBMITTED BY: Don Jungst – Nora/Hagerman City/State: Fishers, IN

PHONE NO.: 317-696-2019

File details come from the government source that posted it. Updated .