This document includes a federal contract solicitation and related project documents for replacing flooring and doors in an Emergency Department at a Veterans Affairs medical center. The solicitation calls for contractors to demolish and remove existing flooring and doors in the ED at the Troy Bowling Campus of the Lexington VAMC in Lexington, Kentucky. Contractors must furnish all labor, materials, and equipment to install new flooring and doors per the drawings and specifications provided. The project documents include an enlarged first floor plan indicating the finish materials to be installed in each area, as well as a legend defining the flooring types. The justification states that the current ED flooring has holes and cracks throughout and needs replacement to avoid injury to patients and staff. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration VISN 9.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UP
TRIAGE 01
C121B
LVT
TRIAGE 02
C121A
LVT
EKG/LAB
C121C
LVT
TLT
C121D
EPOXY
PASSAGE
CH121A
LVT
SOILD UTIL
C122
EPOXY
EMS
C123
EPOXY
SPECIMEN
C124
LVT
SUB-WAITING
CH121B
LVT
PASSAGE
CH121
LVT
PASSAGE
CH125A
LVT
EXAM 11
C125A
WSF
EXAM 12
C125B
WSF
EXAM 13
C125C
WSF
EXAM 14
C125D
WSF
STORAGE
C125E
LVT
EXAM 15
C125F
WSF
EXAM 16
C125G
WSF
TOILET
C126A
EPOXY
PHYS WORK
C126C
LVT
ON CALL
C126D
LVT
PASSAGE
CH126
LVT
CART STORAGE
C125K
LVT
PASSAGE
CH125
LVT
PASSAGE
CH125B
LVT
NOUR PREP
C125J
LVT
CLEAN UTILITY
C125H
WSF
E CYL
C125I
LVT
MED RM
C129
WSF
STORAGE
C127
EXISTING
STAIR
CS104
EXISTING
MENTAL 17
C130A
WSF
OFFICE
C130B
LVT
EXAM 18
C130C
EXISTING
EXAM 19
C130D
WSF
EXAM 1
C130E
WSF
EXAM (NEG) 2
C130F
WSF
VESTIBULE
CH130A
LVT
PASSAGE
CH132
LVT
TLT
C128
EPOXYTLT
C131
EPOXY
EXAM 6
C132A
WSF
STAFF / WORK RM
C133
LVT
TLT/SHOWER
C134
EPOXY
SOILD UTIL
C135
EPOXY
IT
C136
EXISTING
CLEAN UTIL
C137
WSF
EMS
C138
LVT
EXAM 7
C132B
WSF
EXAM 8
C132C
WSF
EXAM 5
C132D
WSF
OFFICE 3
C140
LVT
ER OFFICE 2
C141
LVT
STAFF TLT
C142
EPOXY
ER NURSE MGR
C143
LVT
EMPLOYEE TRAINING RM
C144
LVT
PASSAGE
CH140
LVT
PASSAGE
CH132A
LVT
EXAM (NEG) 3
C130H
WSF
EXAM (NEG) 4
C130I
WSF
EXAM (NEG) 9
C130J
WSF
EXAM 10
C130K
WSF
EC
CU100
EXISTING
ELEVATOR
P7
EXISTING
ELEVATOR
P6
EXISTING IT
C121
EXISTING
PASSAGE
CH130B
LVT
STAIRWELL
CS109
EXISTING
A L
IG
N
ALIGN
A L
IG
N A
L
IG
N
ALIGN
A L
IG
N
1'-9" +/-
STAFF WORK
C130
STAFF WORK
C125
LVT
LVT
LVT1
(RESILIENT TILE SECTION 09 65 19)
WSF
(RESILIENT SHEET FLOORING SECTION 09 65 16)
LVT2
(RESILIENT TILE SECTION 09 65 19)
EXISTING TO REMAIN
FINISH LEGEND
EPOXY
(RESINOUS URETHANE AND EPOXY MORTAR FLOORING
SECTION 09 67 23.60)
NOT IN SCOPE
EXISTING WALL
4" INTEGRAL BASE
EPOXY
EXISTING CONCRETE FLOORING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
12/31/2023
C U s e rs
\d u n n t\ D o c u m e n ts
\R e v it \2
\F F
E L e x in g to n
R e p la c e
E D
F lo o ri n g
(2 tj .d u n n
.r v t
/1
/2
:5
:2
A
M
AF101
ENLARGED FIRST FLOOR PLAN -
FINISHES
Owner
3/17/2023 PH TD
REPLACE FLOORING & EXAM ROOM
DOORS IN ED SUITE
596A4-19-108
LEXINGTON, KY
CONSTRUCTION
DOCUMENTS B-1A
TROY BOWLING
CAMPUS
EMERGENCY
ROOM
G E N E R A L N O T E S
A. TRANSITION BETWEEN LOCKERS AND LOBBY - PROVIDE CTA-XX-HL TRANSITION STRIP.
B. TRANSITION BETWEEN NURSE STATION AND ENTRANCE RAMP - PROVIDE RRS-XX-B TRANSITION STRIP.
C. TRANSITION BETWEEN EXAM 18 AND OFFICE - PROVIDE RUBBER TRANSITION STRIP TO MATCH EXISTING.
D. TRANSITION BETWEEN STAIRWELL AND EXPANSION JOINT - PROVIDE METAL TRANSITION STRIP.
E. 6" RUBBER BASE ON WALLS, 4" RUBBER BASE ON CASEWORK IN ROOMS WITH LVT.
F. 6" FLASH COVE BASE IN ROOMS WITH WSF.
G. 6" INTEGRAL BASE IN ROOMS WITH EPOXY.
1/8" = 1'-0"
FIRST FLOOR PLAN - NEW WORK FINISH PLAN
EXISTING TRANSITIONS
A. B. C. D.
A
B
C
D
KEY PLAN
D R A W I N G N O T E S
1 RELOCATE AND RECONNECT EXISTING LOCKERS UPON COMPLETION OF THE FLOOR REPLACEMENT.
2 EXISTING FLOOR EXPANSION JOINT TO REMAIN - PROTECT FROM DAMAGE DURING CONSTRUCTION - REMOVE COVER AS
REQUIRED FOR FLOOR INSTALLATION AND REINSTALL AT THE CONCLUSION OF WORK.
3" = 1'-0"
INTEGRAL EPOXY BASE DETAIL
No. Revisions: Date:
1 ADDENDUM 01 03/17/2023