Attachment 11 - AD102 - LOWER-LEVEL DEMOLITION PLAN.pdf
PDF 5 MB Posted
- Solicitation number
- 36C24923R0046
About this file
This document includes an attachment to a solicitation for a construction project and the related federal contract opportunity details. The project scope of work involves demolishing and removing existing doors and flooring in the Emergency Department at the Troy Bowling Campus of the Lexington VAMC in Lexington, Kentucky. The contractor will furnish all labor, materials and equipment to install new doors and flooring according to the provided drawings and specifications. The solicitation number is 36C24923R0046 for opportunity Z1DA--Project 596A4-19-108 - Replace ED Flooring - 596-23-2-5821-0002 issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. The justification provided is that the current ED flooring has holes, cracks and other damage throughout, necessitating replacement to avoid patient and staff injury.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MOTOR
CYCLE PARKING
WHEEL
CHAIR PARKING
A006F
A008
PA07PA02
PAE05
PAE04
AH003
PAS04
A006
A006B
A006CA006A
A005A
HAC
STORAGE
STORAGEELEVATOR LOBBY
ELEVATOR
ELEVATOR
CORRIDOR
RETAIL STORE
STAIRWELL
KITCHEN
REFR WALK INPREFAB REFRIG
FOOD
STORAGE
BURGER KING
1B
PLENUM
PAM03
1A
SLOPED RAMP - CEILING MAINTAINS HORIZONTAL PLANE
7'-6" TO ACT
10'-5" TO CONCRETE DECK
8'-7" TO ACT
11'-4" TO ACT
7'-6" TO ACT
11'-6" TO CONCRETE DECK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
12/31/2023
C U s e rs
\d u n n t\ D o c u m e n ts
\R e v it \2
\F F
E L e x in g to n
R e p la c e
E D
F lo o ri n g
(2 tj .d u n n
.r v t
/1
/2
:5
:0
A
M
AD102
LOWER-LEVEL DEMOLITION PLAN
Owner
3/17/2023 PH TD
REPLACE FLOORING & EXAM ROOM
DOORS IN ED SUITE
596A4-19-108
LEXINGTON, KY
CONSTRUCTION
DOCUMENTS B-1A
TROY BOWLING
CAMPUS
EMERGENCY
ROOM
1/8" = 1'-0"
LOWER LEVEL DEMOLITION PLAN
D R A W I N G N O T E S
1 FILL AND REPAIR CONCRETE SLAB ON FLOOR ABOVE. SEE DETAILS 4 AND 5 ON AE501.
G E N E R A L N O T E S
A. CONTRACTOR TO VISIT THE SITE AND RECORD CONDITIONS PRIOR TO START OF DEMOLITION.
B. SEE PHASING PLANS FOR CONSTRUCTION PHASING AND TEMPORARY WALL REQUIREMENTS.
C. REMOVE PREVIOUS FLOOR PENETRATIONS AND PATCH WITH DETAIL ON AE501.
D. NO BUILDING TRASH FACILITIES SHALL BE UTILIZED TO DISPOSE OF DEMOLITION DEBRIS.
E. PROVIDE AND MAINTAIN PROTECTION FOR ALL OTHER REMAINING ITEMS AND AREAS. TAKE EXTRA CAUTION
TO PROTECT FREQUENT USED ACCESS WAYS TO WORK AREA FROM UNUSUAL WEAR AND TEAR.
F. GC TO NOTIFY VA IF ANY HAZARDOUS MATERIALS ARE ENCOUNTERED OR SUSPECTED, AND IS TO EVACUATE AFFECTED WORK AREA IMMEDIATELY AND NOT RETURN TO AREA UNTIL VA HAS CERTIFIED THAT
AREA IS FREE OF HAZARDOUS MATERIALS.
G. WORK ON THIS SHEET WILL NEED TO OCCUR ON NIGHTS OR WEEKENDS TO AVOID TRAFFIC.
H. EXISTING CEILING THROUGHOUT GARAGE IS 2x4 ACOUSTIC CEILING TILE AT APPROXIMATELY 7'-6" A.F.F UNLESS NOTED OTHERWISE. EXISTING BATT INSULATION IS CUT TO 4FT LENGTHS ABOVE THE CEILING TILE.
TEMPORARILY RELOCATE TILE, GRID, AND BATT INSULATION AS NEEDED TO COMPLETE THE WORK.
I. CONTRACTOR MEANS AND METHODS MAY VARY. REINSTALL ANY CEILING TILE AND/OR CEILING GRID RELOCATED TO ACCESS ABOVE CEILING SPACES. REPLACE ANY CEILING TILES AND/OR GRID DAMAGED
DURING CONSTRUCTION.
J. NO ICRA REQUIREMENT FROM GARAGE LEVEL.