This document package includes construction drawings and specifications for a federal contract opportunity to replace flooring and doors in an emergency department at a Veterans Affairs medical center. The scope of work involves demolishing and removing existing flooring and doors in the emergency department at the Troy Bowling Campus of the Lexington VAMC in Lexington, Kentucky. The contractor will then furnish all labor, materials, and equipment to install new doors and flooring according to the drawings and specifications provided. The justification given for the project is that the current emergency department flooring has holes and cracks throughout and needs replacement to avoid injuries to patients and staff. The work will be performed at the Troy Bowling Campus of the Lexington Veterans Affairs Medical Center located in Lexington, Kentucky.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
V .I .F
V.I.F.
7' - 10"
1 3/4"
EXISTING METAL STUD
NEW 6" DOOR JAMB AND PIVOT PLATESEAL PERIMETER
EXISTING DRYWALL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
12/31/2023
C U s e rs
\d u n n t\ D o c u m e n ts
\R e v it \2
\F F
E L e x in g to n
R e p la c e
E D
F lo o ri n g
(2 tj .d u n n
.r v t
/1
/2
:5
:1
A
M
AE601
DOOR DETAILS
Owner
3/17/2023 PH TD
REPLACE FLOORING & EXAM ROOM
DOORS IN ED SUITE
596A4-19-108
LEXINGTON, KY
CONSTRUCTION
DOCUMENTS B-1A
TROY BOWLING
CAMPUS
EMERGENCY
ROOM
DOOR SCHEDULE
DOOR NO. COUNT DOOR TYPE WIDTH HEIGHT
FRAME HEAD
HEIGHT JAMB DEPTH
FRAME JAMB
WIDTH MATERIAL
PHASE 1
C125A 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
C125B 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
C125C 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
C125F 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
C125G 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
PHASE 2
C130K 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
C130J 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
PHASE 3
C130E 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
C130F 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
C130H 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
PHASE 4
C132C 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
C132B 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
C132A 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
C132D 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
C130I 1 TRI-PANEL 7' - 10" 7' - 4" 0' - 6" 0' - 6" 0' - 1 3/4" ALUM.
1/2" = 1'-0"
3 DOOR - FRONT ELEVATION
3" = 1'-0"
DOOR - WALL AND JAMB DETAIL
NOTES:
ALL DOOR TO HAVE SEAL AND LATCHING
BASIS OF DESIGN:
ASSA ABLOY VERSAMAX - 3 DOOR
PACKAGE WIDTH
CLEAR DOOR OPENING
ACTIVE AND SIDELITE WIDTH
BREAKOUT NOMINAL WIDTH
ROUGH OPENING WIDTH
94" 52 7/16" 31 13/16" 80 1/2"" 94 1/2"
No. Revisions: Date:
1 ADDENDUM 01 03/17/2023
Existing doors E-C132E E-C132G have been removed from the Door Schedule as a part of Addendum 01. Doors have been updated to be included in the phase consolidation in Addendum 1.