Attachment 12 - AE101 - ENLARGED FIRST FLOOR PLAN - NEW WORK.pdf
PDF 491 KB Posted
- Solicitation number
- 36C24923R0046
About this file
This solicitation is for replacing flooring and doors in the Emergency Department at the Troy Bowling Campus of the Lexington VA Medical Center in Lexington, Kentucky. The scope of work involves completely preparing the site for demolition and removal of existing doors and flooring in the ED. The contractor will furnish all labor, materials, and equipment to install new doors and flooring per the furnished drawings and specifications. The justification provided is that the current ED flooring has holes and cracks throughout and needs replacing to avoid injury to patients and staff. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UP
TRIAGE 01
C121B
TRIAGE 02
C121A
EKG/LAB
C121C
TLT
C121D
PASSAGE
CH121A
SOILD UTIL
C122
EMS
C123
SPECIMEN
C124
SUB-WAITING
CH121B
PASSAGE
CH121
PASSAGE
CH125A
EXAM 11
C125A
EXAM 12
C125B
EXAM 13
C125C
EXAM 14
C125D
STORAGE
C125E
EXAM 15
C125F
EXAM 16
C125G
TOILET
C126A
PHYS WORK
C126C
ON CALL
C126D
PASSAGE
CH126
CART STORAGE
C125K
PASSAGE
CH125
STAFF WORK
C125
PASSAGE
CH125B
NOUR PREP
C125J
CLEAN UTILITY
C125H
E CYL
C125I
MED RM
C129
STORAGE
C127
STAIR
CS104
MENTAL 17
C130A
OFFICE
C130B
EXAM 18
C130C
EXAM 19
C130D
EXAM 1
C130E
EXAM (NEG) 2
C130F
VESTIBULE
CH130A
PASSAGE
CH132
TLT
C128
TLT
C131
EXAM 6
C132A
STAFF / WORK RM
C133
TLT/SHOWER
C134
SOILD UTIL
C135
IT
C136
CLEAN UTIL
C137
EMS
C138
EXAM 7
C132B
EXAM 8
C132C
EXAM 5
C132D
OFFICE 3
C140
ER OFFICE 2
C141
STAFF TLT
C142
ER NURSE MGR
C143
EMPLOYEE TRAINING RM
C144
PASSAGE
CH140
PASSAGE
CH132A
EXAM (NEG) 3
C130H
EXAM (NEG) 4
C130I
EXAM (NEG) 9
C130J
EXAM 10
C130K
STAIRWELL
CS109
EC
CU100
ELEVATOR
P7
ELEVATOR
P6 IT
C121
PASSAGE
CH130B
C125A C125B C125C
C125F
C125G
C130E
C130F
C130H
C130I
C130KC130J
C132CC132B
C132A
C132D
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE101
STAFF WORK
C130
3' - 5 3/4"
3' - 3 1/4" 3' - 3 1/4"
MIN.
4' - 4 1/2"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
12/31/2023
C U s e rs
\d u n n t\ D o c u m e n ts
\R e v it \2
\F F
E L e x in g to n
R e p la c e
E D
F lo o ri n g
(2 tj .d u n n
.r v t
/1
/2
:5
:0
A
M
AE101
ENLARGED FIRST FLOOR PLAN -
NEW WORK
Owner
3/17/2023 PH TD
REPLACE FLOORING & EXAM ROOM
DOORS IN ED SUITE
596A4-19-108
LEXINGTON, KY
CONSTRUCTION
DOCUMENTS B-1A
TROY BOWLING
CAMPUS
EMERGENCY
ROOM
1/8" = 1'-0"
FIRST FLOOR PLAN - NEW WORK
G E N E R A L N O T E S
A. SEE PHASING PLANS FOR LIMITS OF WORK PER PHASE
B. REFER TO SHEET G001 FOR DRAWING SYMBOLS, INFORMATION AND ABBREVIATIONS.
C. ALL MISCELLANEOUS PAINTING NOT IDENTIFIED IN THE DRAWINGS BUT NECESSARY FOR THE COMPLETION OF THE WORK SHALL BE INCLUDED IN THE PROJECT AND MATCH EXISTING ADJACENT PAINT IN COLOR AND FINISH. CONTRACTOR MEANS AND METHODS MAY RESULT IN A VARYING DEGREE OF PAINT REQUIRED.
SPOT PAINT TO AN ACCEPTABLE LEVEL BY THE VA.
D. CAULKING AND SEALANT ARE TO MATCH ADJACENT SURFACE COLOR. MIN. FLAME SPREAD 76-200, SMOKE
DEVELOPED 0-450).
E. ALL RENOVATED INTERIOR FINISHES SHALL BE CLASS A.
F. ENSURE SURFACES TO RECEIVE FINISHES ARE CLEAN, TRUE AND FREE OF IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. STARTING WORK
SHALL INDICATE APPLICATOR'S ACCEPTANCE OF SUBSTRATE.
G. ALL FLOORING SURFACES SHALL BE SLIP RESISTANT PER ADA/ABA RECOMMENDATIONS AND
REQUIREMENTS.
H. REFER TO APPLICABLE FLOORING SPECIFICATIONS FOR FLOOR LEVELNESS REQUIREMENTS. FLASH PATCH
UNEVEN FLOOR AREAS AS REQUIRED.
I. FLOOR FINISHES TO EXTEND UNDER MILLWORK WHEREVER CABINET SPACES ARE OPEN TO FLOOR.
J. ENSURE SURFACES TO RECEIVE FINISHES ARE CLEAN, TRUE AND FREE OF IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. STARTING WORK
SHALL INDICATE APPLICATOR'S ACCEPTANCE OF SUBSTRATE.
K. PREPARE FLOOR AREAS AS REQUIRED TO RECEIVE FLOOR FINISHES, INCLUDING FLASH PATCHING REQUIRED TO LEVEL AND SMOOTH FLOOR TO 1/4” IN 20' - 0” NON-CUMULATIVE. CONCRETE FLOORS SHALL BE FREE FROM SCALING AND IRREGULARITIES AND SHALL EXHIBIT NEUTRALITY RELATIVE TO ACIDITY AND
ALKALINITY.
1/4" = 1'-0"
FIRST FLOOR PLAN - EXISTING DOOR DIAGRAM
1/4" = 1'-0"
FIRST FLOOR PLAN - NEW DOOR DIAGRAM
D R A W I N G N O T E S
1 EXISTING FLOOR EXPANSION JOINT TO REMAIN - PROTECT FROM DAMAGE DURING CONSTRUCTION - REMOVE COVER AS
REQUIRED FOR FLOOR INSTALLATION AND REINSTALL AT THE CONCLUSION OF WORK.
2 RELOCATE AND RECONNECT EXISTING LOCKERS UPON COMPLETION OF THE FLOOR REPLACEMENT.
KEY PLAN
No. Revisions: Date:
1 ADDENDUM 01 03/17/2023
VA REFERENCE ONLY VA REFERENCE ONLY
| Sheets |
| AE101 - ENLARGED FIRST FLOOR PLAN - NEW WORK |
File details come from the government source that posted it. Updated .