Set 9 Drawings Fire Alarm New Site and Building 1.pdf

PDF 14 MB Posted

Attached to
Project 614-19-111, Replace Fire Alarm System Federal contract opportunity
Solicitation number
36C24921R0070
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9

About this file

This document provides details for a federal contract opportunity to replace the fire alarm system at the Memphis VA Medical Center. The solicitation seeks a construction contractor to provide all labor, materials, equipment, supervision and quality control for a complete replacement of the existing Notifier 3300 fire alarm system with a new code compliant system. The replacement system must include all necessary control panels, initiating devices, notification devices, control modules and other components. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. Interested offerors should review the set of contract drawings and specifications for additional requirements.

View the file

Other files for this federal contract opportunity

Other files attached to Project 614-19-111, Replace Fire Alarm System, newest first.
File Type Posted
36C24921R0070 0006.pdf PDF
P07-General Decision Number TN20210111 02.12.2021 (Shelby Cty).pdf PDF
P07-General Decision Number TN20210111 01.01.2021.pdf PDF
S02-Price Schedule (Proj 614-19-111).xlsx XLSX spreadsheet
36C24921R0070 0005.pdf PDF
36C24921R0070 0004.pdf PDF
RFI 1 Memphis TN -rev.pdf PDF
S06-36C24921R0070 0003.pdf PDF
RFI 1 Memphis TN.pdf PDF
Govt Response_21-B-042 Memphis Fire Alarm Repairs RFIs.pdf PDF
Govt Response_ISS Estimating.pdf PDF
Govt Response_ Project 614-19-111 Memphis VA Fire Alarm Replacement.pdf PDF
Govt Response _ RFI Fire Alarm Soc. 36C24921R0070.pdf PDF
S06-36C24921R0070 0002.pdf PDF
S06-36C24921R0070 0001.pdf PDF
S02-36C24921R0070 (Repl Fire Alarm)_04.05.2021.pdf PDF
Set 11 Drawings Fire Alarm New B5 B6 B7 B10 and PG.pdf PDF
Set 2 Drawings Electrical Photos_Part1.pdf PDF
Set 6 Drawings Fire Alarm Demo Site and Building 1.pdf PDF
Set 12 Drawings Electrical Power.pdf PDF
Set 1 Drawings General.pdf PDF
C28-Project Specifications 614-19-111 (Repl Fire Alarm).pdf PDF
Set 10 Drawings Fire Alarm New Building 1A.pdf PDF
Set 7 Drawings Fire Alarm Demo Building 1A.pdf PDF
Set 3 Drawings Electrical Photos_Part2.pdf PDF
Set 4 Drawings Fire Alarm General and Risers_Part1.pdf PDF
36C24921R0070_1 (presolicitation notice).pdf PDF
Show all 27

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VAN/CAR

VAN/CAR

VAN/CAR

VAN/CAR

VAN/CAR

VAN/CAR

VAN/CAR

VAN/CAR

CAR

CAR

VAN/CAR

VAN/CAR

VAN/CAR

VAN/CAR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Architecture Engineering Design-Build paradigm

AutoCAD SHX Text J E F F E R S O N A V E N U E

AutoCAD SHX Text P A U L I N E S T R E E T

AutoCAD SHX Text W A L D R A N S T R E E T

AutoCAD SHX Text S O M E R V I L L E S T R E E T

AutoCAD SHX Text P O P L A R A V E N U E

AutoCAD SHX Text

OUTPATIENT/

AutoCAD SHX Text

VISTOR

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

EMPLOYEE

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

OUTPATIENT/

AutoCAD SHX Text

VISTOR

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

FAST FOOD

AutoCAD SHX Text

LEBONHEUR CHILDRENS MEDICAL CENTER PARKING

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text

MEMPHIS CHILD ADVOCACY CTR

AutoCAD SHX Text

BED TOWER

AutoCAD SHX Text 1A

AutoCAD SHX Text

ADMINISTRATION BUILDING

AutoCAD SHX Text

AutoCAD SHX Text

AMBULATORY CARE

AutoCAD SHX Text

AutoCAD SHX Text

MRI

AutoCAD SHX Text

AutoCAD SHX Text

SCI BLDG

AutoCAD SHX Text

AutoCAD SHX Text

CLINIC ANNEX

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

FIRE

AutoCAD SHX Text

HYDRANT

AutoCAD SHX Text

FIRE

AutoCAD SHX Text

HYDRANT

AutoCAD SHX Text

FIRE

AutoCAD SHX Text

HYDRANT

AutoCAD SHX Text

FIRE

AutoCAD SHX Text

HYDRANT

AutoCAD SHX Text

FIRE

AutoCAD SHX Text

HYDRANT

AutoCAD SHX Text

WATER

AutoCAD SHX Text

SHUT OFF

AutoCAD SHX Text

VALVE

AutoCAD SHX Text

PIV

AutoCAD SHX Text

PIV

AutoCAD SHX Text

PIV

AutoCAD SHX Text

PIV

AutoCAD SHX Text

PIV

AutoCAD SHX Text

PIV

AutoCAD SHX Text

MM

AutoCAD SHX Text

MM

AutoCAD SHX Text

MM

AutoCAD SHX Text

MM

AutoCAD SHX Text

MM

AutoCAD SHX Text

MM

AutoCAD SHX Text

FIRE

AutoCAD SHX Text

HYDRANT

AutoCAD SHX Text

PIV

AutoCAD SHX Text

MM

AutoCAD SHX Text

FIRE

AutoCAD SHX Text

HYDRANT

AutoCAD SHX Text

PIV

AutoCAD SHX Text

MM

AutoCAD SHX Text

FAES

AutoCAD SHX Text

KMB

AutoCAD SHX Text

FIRE ALARM SITE PLAN

AutoCAD SHX Text

WLM

AutoCAD SHX Text

VARIES

AutoCAD SHX Text F1

AutoCAD SHX Text

SCALE 1/64'' = 1'-0''

AutoCAD SHX Text

FIRE ALARM SITE PLAN

AutoCAD SHX Text N

AutoCAD SHX Text

GENERAL NOTES A. ..

AutoCAD SHX Text GENERAL NOTES A. REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, SCHEDULES AND GENERAL NOTES. B. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATE AT EACH FIRE ALARM DEVICE. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION BOX AT EACH FIRE ALARM DEVICE INDICATED ON FLOOR PLANS. D. THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" CONDUIT FROM EACH FIRE ALARM DEVICE TO NEW FACP OR NAC PANELS. E. CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT SHALL NOT BE ALLOWED. F. THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM CONDUIT SYSTEM RED IN COLOR. G. ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE RIGID STEEL, NON-METALLIC TUBING SHALL NOT BE PERMITTED. H. THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND PATCHING ON ALL WALL OR CEILING OPENINGS. I. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY ENGINEERED SHOP DRAWINGS SUBMITTALS OF THE PROPOSED WORK PRIOR TO BEGINNING CONSTRUCTION. THE SHOP DRAWING SUBMITTALS SHALL INCLUDE BUT NOT LIMITED TO: VOLTAGE DROP CALCULATIONS, BATTERY CALCULATIONS, INSULATION VALUE, LENGTH OF WIRE, SLC WIRING DIAGRAM, NAC WIRING DIAGRAM ETC. J. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE PARADIGM ENGINEERING COMPLETED COORDINATION DRAWINGS AT CONCLUSION OF PROJECT, PARADIGM ENGINEERING WILL BEGIN AS-BUILT DRAWINGS WITHOUT COMPLETED COORDINATION DRAWINGS FROM CONTRACTOR. K. THE CONTRACTOR SHALL INSTALL PIV (POST INDICATOR VALVE) THE CONTRACTOR SHALL INSTALL PIV (POST INDICATOR VALVE) AS INDICATED ON DRAWING. INSTALL PIV BASED ON PIPE SIZE . INSTALL PIV BASED ON PIPE SIZE AND DIMENSIONS OF EXISTING PIPE. L. THE CONTRACTOR SHALL UTILIZE EXISTING PIPING TO PULL THE CONTRACTOR SHALL UTILIZE EXISTING PIPING TO PULL NEW FIRE ALARM WIRING TO NEW PIV LOCATIONS, AutoCAD SHX Text 200 Envoy Circle, Suite 201, Louisville, KY 40299 www.paradigmusa.com

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text

FULLY SPRINKLERED

AutoCAD SHX Text

REPLACE FIRE ALARM SYSTEM

AutoCAD SHX Text 614-19-111

AutoCAD SHX Text 06-24-2020

AutoCAD SHX Text

1030 JEFFERSON AVE, MEMPHIS, TN 38104

AutoCAD SHX Text

MEMPHIS VA MEDICAL CENTER

STAIR

NO. 9

TSAIM

F1:L6:002

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Architecture Engineering Design-Build paradigm

AutoCAD SHX Text

1.FA099A

AutoCAD SHX Text

KMB

AutoCAD SHX Text

FIRE ALARM PLAN BUILDING 1 BASEMENT AREA A

AutoCAD SHX Text

WLM

AutoCAD SHX Text F1

AutoCAD SHX Text

SCALE 1/8'' = 1'-0''

AutoCAD SHX Text

FIRE ALARM PLAN BUILDING NO. 1 - BASEMENT AREA "A"

AutoCAD SHX Text N

AutoCAD SHX Text 200 Envoy Circle, Suite 201, Louisville, KY 40299 www.paradigmusa.com

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text

FULLY SPRINKLERED

AutoCAD SHX Text

REPLACE FIRE ALARM SYSTEM

AutoCAD SHX Text 614-19-111

AutoCAD SHX Text 06-24-2020

AutoCAD SHX Text

1030 JEFFERSON AVE, MEMPHIS, TN 38104

AutoCAD SHX Text

MEMPHIS VA MEDICAL CENTER

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099C

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099C

AutoCAD SHX Text F1

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

KEY PLAN - BASEMENT

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text GENERAL NOTES A. REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, SCHEDULES AND GENERAL NOTES. B. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATE AT EACH FIRE ALARM DEVICE. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION BOX AT EACH FIRE ALARM DEVICE INDICATED ON FLOOR PLANS. D. THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" CONDUIT FROM EACH FIRE ALARM DEVICE TO NEW FACP OR NAC PANELS. E. CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT SHALL NOT BE ALLOWED. F. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATES AT EACH FIRE ALARM DEVICE. G. THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM CONDUIT SYSTEM RED IN COLOR. H. ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT (ELECTRICAL METALLIC TUBING). I. ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE RIGID STEEL, NON-METALLIC TUBING SHALL NOT BE PERMITTED. J. THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND PATCHING ON ALL WALL OR CEILING OPENINGS. K. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY ENGINEERED SHOP DRAWINGS SUBMITTALS OF THE PROPOSED WORK PRIOR TO BEGINNING CONSTRUCTION. THE SHOP DRAWING SUBMITTALS SHALL INCLUDE BUT NOT LIMITED TO: VOLTAGE DROP CALCULATIONS, BATTERY CALCULATIONS, INSULATION VALUE, LENGTH OF WIRE, SLC WIRING DIAGRAM, NAC WIRING DIAGRAM ETC. L. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE PARADIGM ENGINEERING COMPLETED COORDINATION DRAWINGS AT CONCLUSION OF PROJECT, PARADIGM ENGINEERING WILL BEGIN AS-BUILT DRAWINGS WITHOUT COMPLETED COORDINATION DRAWINGS FROM CONTRACTOR. M. REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND VOLT DROP CALCULATIONS. N. REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER DIAGRAM.

AutoCAD SHX Text THE EXISTING CEILING GRID SYSTEM IS EXISTING TO REMAIN. THE CONTRACTOR SHALL REMOVE TILE AS REQUIRED TO INSTALL NEW CONDUIT. THE REMOVAL OF CEILING TILE AND INSTALLATION OF CONDUIT SHALL BE COORDINATED WITH VAMC AND SHALL COMPLY WITH INFECTION CONTROL STANDARDS SET BY THE VAMC. REFER REFER TO FLOOR PLAN FOR ROUTING OF NEW CONDUIT AND CIRCUITING INFORMATION.

AutoCAD SHX Text

CEILING WORK NOTE

AutoCAD SHX Text A7

SCOPE OF WORK:: A. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE ALARM DEVICES THROUGHOUT, UNLESS NOTED OTHERWISE. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. B. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW CONDUIT AND FIRE ALARM CABLING THROUGHOUT, REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR MODULES AS INDICATED ON FLOOR PLANS TO EXISTING TO REMAIN FIRE ALARM DEVICES. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. D. THE FIRE ALARM CONTRACTOR SHALL USE TAMPER THE FIRE ALARM CONTRACTOR SHALL USE TAMPER PROOF SCREWS THROUGHOUT. E. THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT (ELECTRICAL METALLIC TUBING) WHEN INSTALLING CONDUIT INDOORS. F. THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID ALUMINUM OR RIGID STEEL WHEN INSTALLING CONDUIT OUTDOORS.

N

L

M

J

K

P4

P2

P1

P

P3

TSAIM

F1:L6:006

TSAIM

F1:L6:005

TSAIM

F1:L6:008

TSAIM

F1:L6:004

TSAIM

F1:L6:007

TSAIM

F1:L6:009

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Architecture Engineering Design-Build paradigm

AutoCAD SHX Text

1.FA099B

AutoCAD SHX Text

KMB

AutoCAD SHX Text

WLM

AutoCAD SHX Text F3

AutoCAD SHX Text N

AutoCAD SHX Text 200 Envoy Circle, Suite 201, Louisville, KY 40299 www.paradigmusa.com

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text

FULLY SPRINKLERED

AutoCAD SHX Text

REPLACE FIRE ALARM SYSTEM

AutoCAD SHX Text 614-19-111

AutoCAD SHX Text 06-24-2020

AutoCAD SHX Text

1030 JEFFERSON AVE, MEMPHIS, TN 38104

AutoCAD SHX Text

MEMPHIS VA MEDICAL CENTER

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099C

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099C

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099D

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099D

AutoCAD SHX Text F3

AutoCAD SHX Text

SCALE 1/8'' = 1'-0''

AutoCAD SHX Text

FIRE ALARM PLAN BUILDING NO. 1 - BASEMENT AREA "B"

AutoCAD SHX Text

FIRE ALARM PLAN BUILDING 1 BASEMENT AREA B

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

KEY PLAN - BASEMENT

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text GENERAL NOTES A. REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, SCHEDULES AND GENERAL NOTES. B. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATE AT EACH FIRE ALARM DEVICE. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION BOX AT EACH FIRE ALARM DEVICE INDICATED ON FLOOR PLANS. D. THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" CONDUIT FROM EACH FIRE ALARM DEVICE TO NEW FACP OR NAC PANELS. E. CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT SHALL NOT BE ALLOWED. F. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATES AT EACH FIRE ALARM DEVICE. G. THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM CONDUIT SYSTEM RED IN COLOR. H. ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT (ELECTRICAL METALLIC TUBING). I. ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE RIGID STEEL, NON-METALLIC TUBING SHALL NOT BE PERMITTED. J. THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND PATCHING ON ALL WALL OR CEILING OPENINGS. K. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY ENGINEERED SHOP DRAWINGS SUBMITTALS OF THE PROPOSED WORK PRIOR TO BEGINNING CONSTRUCTION. THE SHOP DRAWING SUBMITTALS SHALL INCLUDE BUT NOT LIMITED TO: VOLTAGE DROP CALCULATIONS, BATTERY CALCULATIONS, INSULATION VALUE, LENGTH OF WIRE, SLC WIRING DIAGRAM, NAC WIRING DIAGRAM ETC. L. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE PARADIGM ENGINEERING COMPLETED COORDINATION DRAWINGS AT CONCLUSION OF PROJECT, PARADIGM ENGINEERING WILL BEGIN AS-BUILT DRAWINGS WITHOUT COMPLETED COORDINATION DRAWINGS FROM CONTRACTOR. M. REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND VOLT DROP CALCULATIONS. N. REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER DIAGRAM.

AutoCAD SHX Text THE EXISTING CEILING GRID SYSTEM IS EXISTING TO REMAIN. THE CONTRACTOR SHALL REMOVE TILE AS REQUIRED TO INSTALL NEW CONDUIT. THE REMOVAL OF CEILING TILE AND INSTALLATION OF CONDUIT SHALL BE COORDINATED WITH VAMC AND SHALL COMPLY WITH INFECTION CONTROL STANDARDS SET BY THE VAMC. REFER REFER TO FLOOR PLAN FOR ROUTING OF NEW CONDUIT AND CIRCUITING INFORMATION.

AutoCAD SHX Text

CEILING WORK NOTE

AutoCAD SHX Text A7

SCOPE OF WORK:: A. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE ALARM DEVICES THROUGHOUT, UNLESS NOTED OTHERWISE. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. B. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW CONDUIT AND FIRE ALARM CABLING THROUGHOUT, REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR MODULES AS INDICATED ON FLOOR PLANS TO EXISTING TO REMAIN FIRE ALARM DEVICES. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. D. THE FIRE ALARM CONTRACTOR SHALL USE TAMPER THE FIRE ALARM CONTRACTOR SHALL USE TAMPER PROOF SCREWS THROUGHOUT. E. THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT (ELECTRICAL METALLIC TUBING) WHEN INSTALLING CONDUIT INDOORS. F. THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID ALUMINUM OR RIGID STEEL WHEN INSTALLING CONDUIT OUTDOORS.

18 1917

NO. 11

TSAIM

F1:L6:003

TSAIM

F1:L6:001

TSAIM

F1:L6:012

TS

TS

TS

AIM F1:L6:010

4-I/0

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Architecture Engineering Design-Build paradigm

AutoCAD SHX Text

1.FA099C

AutoCAD SHX Text

KMB

AutoCAD SHX Text

FIRE ALARM PLAN BUILDING 1 BASEMENT AREA C

AutoCAD SHX Text

WLM

AutoCAD SHX Text F1

AutoCAD SHX Text N

AutoCAD SHX Text 200 Envoy Circle, Suite 201, Louisville, KY 40299 www.paradigmusa.com

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text

FULLY SPRINKLERED

AutoCAD SHX Text

REPLACE FIRE ALARM SYSTEM

AutoCAD SHX Text 614-19-111

AutoCAD SHX Text 06-24-2020

AutoCAD SHX Text

1030 JEFFERSON AVE, MEMPHIS, TN 38104

AutoCAD SHX Text

MEMPHIS VA MEDICAL CENTER

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099A

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099B

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099A

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099B

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099E

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099E

AutoCAD SHX Text F1

AutoCAD SHX Text

SCALE 1/8'' = 1'-0''

AutoCAD SHX Text

FIRE ALARM PLAN BUILDING NO. 1 - BASEMENT AREA "C"

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

KEY PLAN - BASEMENT

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text GENERAL NOTES A. REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, SCHEDULES AND GENERAL NOTES. B. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATE AT EACH FIRE ALARM DEVICE. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION BOX AT EACH FIRE ALARM DEVICE INDICATED ON FLOOR PLANS. D. THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" CONDUIT FROM EACH FIRE ALARM DEVICE TO NEW FACP OR NAC PANELS. E. CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT SHALL NOT BE ALLOWED. F. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATES AT EACH FIRE ALARM DEVICE. G. THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM CONDUIT SYSTEM RED IN COLOR. H. ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT (ELECTRICAL METALLIC TUBING). I. ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE RIGID STEEL, NON-METALLIC TUBING SHALL NOT BE PERMITTED. J. THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND PATCHING ON ALL WALL OR CEILING OPENINGS. K. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY ENGINEERED SHOP DRAWINGS SUBMITTALS OF THE PROPOSED WORK PRIOR TO BEGINNING CONSTRUCTION. THE SHOP DRAWING SUBMITTALS SHALL INCLUDE BUT NOT LIMITED TO: VOLTAGE DROP CALCULATIONS, BATTERY CALCULATIONS, INSULATION VALUE, LENGTH OF WIRE, SLC WIRING DIAGRAM, NAC WIRING DIAGRAM ETC. L. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE PARADIGM ENGINEERING COMPLETED COORDINATION DRAWINGS AT CONCLUSION OF PROJECT, PARADIGM ENGINEERING WILL BEGIN AS-BUILT DRAWINGS WITHOUT COMPLETED COORDINATION DRAWINGS FROM CONTRACTOR. M. REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND VOLT DROP CALCULATIONS. N. REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER DIAGRAM.

AutoCAD SHX Text THE EXISTING CEILING GRID SYSTEM IS EXISTING TO REMAIN. THE CONTRACTOR SHALL REMOVE TILE AS REQUIRED TO INSTALL NEW CONDUIT. THE REMOVAL OF CEILING TILE AND INSTALLATION OF CONDUIT SHALL BE COORDINATED WITH VAMC AND SHALL COMPLY WITH INFECTION CONTROL STANDARDS SET BY THE VAMC. REFER REFER TO FLOOR PLAN FOR ROUTING OF NEW CONDUIT AND CIRCUITING INFORMATION.

AutoCAD SHX Text

CEILING WORK NOTE

AutoCAD SHX Text A7

SCOPE OF WORK:: A. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE ALARM DEVICES THROUGHOUT, UNLESS NOTED OTHERWISE. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. B. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW CONDUIT AND FIRE ALARM CABLING THROUGHOUT, REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR MODULES AS INDICATED ON FLOOR PLANS TO EXISTING TO REMAIN FIRE ALARM DEVICES. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. D. THE FIRE ALARM CONTRACTOR SHALL USE TAMPER THE FIRE ALARM CONTRACTOR SHALL USE TAMPER PROOF SCREWS THROUGHOUT. E. THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT (ELECTRICAL METALLIC TUBING) WHEN INSTALLING CONDUIT INDOORS. F. THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID ALUMINUM OR RIGID STEEL WHEN INSTALLING CONDUIT OUTDOORS.

H

NO. 1

STAIR

NO. 3

TSAIM

F1:L6:018

TSAIM

F1:L6:022

TSAIM

F1:L6:021

TSAIMF1:L6:020 TSAIM

F1:L6:019

TSAIMF1:L6:015

TS

AIM F1:L6:017

DTS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Architecture Engineering Design-Build paradigm

AutoCAD SHX Text

1.FA099D

AutoCAD SHX Text

KMB

AutoCAD SHX Text

FIRE ALARM PLAN BUILDING 1 BASEMENT AREA D

AutoCAD SHX Text

WLM

AutoCAD SHX Text F1

AutoCAD SHX Text N

AutoCAD SHX Text 200 Envoy Circle, Suite 201, Louisville, KY 40299 www.paradigmusa.com

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text

FULLY SPRINKLERED

AutoCAD SHX Text

REPLACE FIRE ALARM SYSTEM

AutoCAD SHX Text 614-19-111

AutoCAD SHX Text 06-24-2020

AutoCAD SHX Text

1030 JEFFERSON AVE, MEMPHIS, TN 38104

AutoCAD SHX Text

MEMPHIS VA MEDICAL CENTER

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099B

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099E

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099B

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099E

AutoCAD SHX Text F1

AutoCAD SHX Text

SCALE 1/8'' = 1'-0''

AutoCAD SHX Text

FIRE ALARM PLAN BUILDING NO. 1 - BASEMENT AREA "D"

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

KEY PLAN - BASEMENT

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text GENERAL NOTES A. REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, SCHEDULES AND GENERAL NOTES. B. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATE AT EACH FIRE ALARM DEVICE. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION BOX AT EACH FIRE ALARM DEVICE INDICATED ON FLOOR PLANS. D. THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" CONDUIT FROM EACH FIRE ALARM DEVICE TO NEW FACP OR NAC PANELS. E. CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT SHALL NOT BE ALLOWED. F. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATES AT EACH FIRE ALARM DEVICE. G. THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM CONDUIT SYSTEM RED IN COLOR. H. ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT (ELECTRICAL METALLIC TUBING). I. ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE RIGID STEEL, NON-METALLIC TUBING SHALL NOT BE PERMITTED. J. THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND PATCHING ON ALL WALL OR CEILING OPENINGS. K. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY ENGINEERED SHOP DRAWINGS SUBMITTALS OF THE PROPOSED WORK PRIOR TO BEGINNING CONSTRUCTION. THE SHOP DRAWING SUBMITTALS SHALL INCLUDE BUT NOT LIMITED TO: VOLTAGE DROP CALCULATIONS, BATTERY CALCULATIONS, INSULATION VALUE, LENGTH OF WIRE, SLC WIRING DIAGRAM, NAC WIRING DIAGRAM ETC. L. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE PARADIGM ENGINEERING COMPLETED COORDINATION DRAWINGS AT CONCLUSION OF PROJECT, PARADIGM ENGINEERING WILL BEGIN AS-BUILT DRAWINGS WITHOUT COMPLETED COORDINATION DRAWINGS FROM CONTRACTOR. M. REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND VOLT DROP CALCULATIONS. N. REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER DIAGRAM.

AutoCAD SHX Text THE EXISTING CEILING GRID SYSTEM IS EXISTING TO REMAIN. THE CONTRACTOR SHALL REMOVE TILE AS REQUIRED TO INSTALL NEW CONDUIT. THE REMOVAL OF CEILING TILE AND INSTALLATION OF CONDUIT SHALL BE COORDINATED WITH VAMC AND SHALL COMPLY WITH INFECTION CONTROL STANDARDS SET BY THE VAMC. REFER REFER TO FLOOR PLAN FOR ROUTING OF NEW CONDUIT AND CIRCUITING INFORMATION.

AutoCAD SHX Text

CEILING WORK NOTE

AutoCAD SHX Text A7

SCOPE OF WORK:: A. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE ALARM DEVICES THROUGHOUT, UNLESS NOTED OTHERWISE. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. B. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW CONDUIT AND FIRE ALARM CABLING THROUGHOUT, REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR MODULES AS INDICATED ON FLOOR PLANS TO EXISTING TO REMAIN FIRE ALARM DEVICES. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. D. THE FIRE ALARM CONTRACTOR SHALL USE TAMPER THE FIRE ALARM CONTRACTOR SHALL USE TAMPER PROOF SCREWS THROUGHOUT. E. THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT (ELECTRICAL METALLIC TUBING) WHEN INSTALLING CONDUIT INDOORS. F. THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID ALUMINUM OR RIGID STEEL WHEN INSTALLING CONDUIT OUTDOORS.

A.1

B.1

C.1

D.1

E.1

E

D

C

B

A

F

G

STAIR

NO. 4

TSAIM

F1:L6:011

TSAIMF1:L6:013

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Architecture Engineering Design-Build paradigm

AutoCAD SHX Text

1.FA099E

AutoCAD SHX Text

KMB

AutoCAD SHX Text

FIRE ALARM PLAN BUILDING 1 BASEMENT AREA E

AutoCAD SHX Text

WLM

AutoCAD SHX Text F1

AutoCAD SHX Text N

AutoCAD SHX Text 200 Envoy Circle, Suite 201, Louisville, KY 40299 www.paradigmusa.com

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text

FULLY SPRINKLERED

AutoCAD SHX Text

REPLACE FIRE ALARM SYSTEM

AutoCAD SHX Text 614-19-111

AutoCAD SHX Text 06-24-2020

AutoCAD SHX Text

1030 JEFFERSON AVE, MEMPHIS, TN 38104

AutoCAD SHX Text

MEMPHIS VA MEDICAL CENTER

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099C

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099D

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099C

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FD099D

AutoCAD SHX Text F1

AutoCAD SHX Text

SCALE 1/8'' = 1'-0''

AutoCAD SHX Text

FIRE ALARM PLAN BUILDING NO. 1 - BASEMENT AREA "E"

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

KEY PLAN - BASEMENT

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text GENERAL NOTES A. REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, SCHEDULES AND GENERAL NOTES. B. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATE AT EACH FIRE ALARM DEVICE. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION BOX AT EACH FIRE ALARM DEVICE INDICATED ON FLOOR PLANS. D. THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" CONDUIT FROM EACH FIRE ALARM DEVICE TO NEW FACP OR NAC PANELS. E. CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT SHALL NOT BE ALLOWED. F. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATES AT EACH FIRE ALARM DEVICE. G. THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM CONDUIT SYSTEM RED IN COLOR. H. ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT (ELECTRICAL METALLIC TUBING). I. ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE RIGID STEEL, NON-METALLIC TUBING SHALL NOT BE PERMITTED. J. THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND PATCHING ON ALL WALL OR CEILING OPENINGS. K. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY ENGINEERED SHOP DRAWINGS SUBMITTALS OF THE PROPOSED WORK PRIOR TO BEGINNING CONSTRUCTION. THE SHOP DRAWING SUBMITTALS SHALL INCLUDE BUT NOT LIMITED TO: VOLTAGE DROP CALCULATIONS, BATTERY CALCULATIONS, INSULATION VALUE, LENGTH OF WIRE, SLC WIRING DIAGRAM, NAC WIRING DIAGRAM ETC. L. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE PARADIGM ENGINEERING COMPLETED COORDINATION DRAWINGS AT CONCLUSION OF PROJECT, PARADIGM ENGINEERING WILL BEGIN AS-BUILT DRAWINGS WITHOUT COMPLETED COORDINATION DRAWINGS FROM CONTRACTOR. M. REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND VOLT DROP CALCULATIONS. N. REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER DIAGRAM.

AutoCAD SHX Text THE EXISTING CEILING GRID SYSTEM IS EXISTING TO REMAIN. THE CONTRACTOR SHALL REMOVE TILE AS REQUIRED TO INSTALL NEW CONDUIT. THE REMOVAL OF CEILING TILE AND INSTALLATION OF CONDUIT SHALL BE COORDINATED WITH VAMC AND SHALL COMPLY WITH INFECTION CONTROL STANDARDS SET BY THE VAMC. REFER REFER TO FLOOR PLAN FOR ROUTING OF NEW CONDUIT AND CIRCUITING INFORMATION.

AutoCAD SHX Text

CEILING WORK NOTE

AutoCAD SHX Text A7

SCOPE OF WORK:: A. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE ALARM DEVICES THROUGHOUT, UNLESS NOTED OTHERWISE. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. B. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW CONDUIT AND FIRE ALARM CABLING THROUGHOUT, REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR MODULES AS INDICATED ON FLOOR PLANS TO EXISTING TO REMAIN FIRE ALARM DEVICES. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. D. THE FIRE ALARM CONTRACTOR SHALL USE TAMPER THE FIRE ALARM CONTRACTOR SHALL USE TAMPER PROOF SCREWS THROUGHOUT. E. THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT (ELECTRICAL METALLIC TUBING) WHEN INSTALLING CONDUIT INDOORS. F. THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID ALUMINUM OR RIGID STEEL WHEN INSTALLING CONDUIT OUTDOORS.

DN

P5

U.7

V.8

V.9

U.1

3 3.2

4 5 6 7 8 9

Q

R

S

T

U

V

W

9.28.37.97.16.25.84.94.13.62.71.91.30.7

FIRE

EXTINGUISHER

MECH RM

AWG 19

AW-C12

MENS LOCKER RM

AWG10

AWG 10A

SWITCHGEAR

AWG 15

ELEV MECH RM

AWG 8

CORRIDOR

AW-C11

AWG 17

LOGISTICS

AWG 16

CONFERENCE

AWG18

LOGISTICS

AWG 20

TOILET

AWG 22

LOGISTICS

AWG 24

AWG 24A

MECH RM

AWG 21

MEZZANINE

AWG 23

STAIR 13

WATER

TREATMENT

AWG 26A

OFFICE

AWG 27

CLOSET

AWG18A

LOGISTICS

AWG 24B

LOGISTICS

AWG 20A

LOGISTICS

AWG 20B

F1:L5:190

F1:L5:191

S

F1:L5:195

F1:S15:33

PS6:N3:03

15cd 0.5w

F1:S15:34

PS6:N3:02

15cd 0.5w

F1:N9:03 F1:S9:03 75cd 0.5w

F1:N9:01 F1:S9:01 75cd 0.5w

F1:N9:02 F1:S9:02 15cd 0.5w

F1:N9:05 F1:S9:05 75cd 0.5w

F1:N9:04 F1:S9:04 75cd 0.5w

F1:N9:11 F1:S9:11 75cd 0.5w

F1:N9:06 F1:S9:06 75cd 0.5w

F1:N9:12 EOL

F1:S9:12 EOL

75cd 0.5w

F1:N9:08 F1:S9:08 75cd 0.5w

F1:N9:07 F1:S9:07 75cd 0.5w

F1:N9:09 F1:S9:09 15cd 0.5w

F1:N9:10 F1:S9:10 15cd 0.5w

F1:N10:02 F1:S10:03 15cd 0.5w

F1:N10:03 F1:S10:06 15cd 0.5w

F1:N10:06 F1:S10:10 15cd 0.5w

F1:N10:07 F1:S10:11 15cd 0.5w

F1:N10:11 EOL

15cd

F1:N10:10

F1:S10:15 EOL

15cd 0.5w

F1:N10:08 F1:S10:12 15cd 0.5w

F1:N10:04 F1:S10:07 15cd 0.5w

F1:N10:05 F1:S10:09 15cd 0.5w

F1:L5:194F1:L5:193

TS

FS

TS

TS FS

S F1:L5:183

DH

DH

PS6:N3:04

15cd

F1:L5:182

AIM

F1:L5:192 D

AIM

F1:L5:188 D

AIM

F1:L5:189 D

S

F1:S10:02 0.5w

S

F1:S10:04 0.5w

S

F1:S10:05 0.5w

S F1:S10:08 0.5w

S

F1:S10:13 0.5w

AIM F1:L5:186

4-I/0

FP

PUMP RUNNING

POWER FAIL

PHASE REVERSAL

S

F1:L5:197 F1:N10:09 F1:S10:14 15cd 0.5w

F1:L5:196

TS

TS

TS

TS

AIM F1:L5:187

4-I/0

FS

AOM

F1:L5:181

BOILER

RM

AWG 26

OFFICE

MAGNETIC

LOCK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Architecture Engineering Design-Build paradigm

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text

1.FA100A

AutoCAD SHX Text

KMB

AutoCAD SHX Text

NEW FIRE ALARM PLAN BUILDING 1 GROUND FLOOR AREA A

AutoCAD SHX Text

WLM

AutoCAD SHX Text F1

AutoCAD SHX Text F1

AutoCAD SHX Text

SCALE 1/8'' = 1'-0''

AutoCAD SHX Text

NEW FIRE ALARM PLAN BUILDING NO. 1 - GROUND FLOOR AREA "A"

AutoCAD SHX Text N

AutoCAD SHX Text 200 Envoy Circle, Suite 201, Louisville, KY 40299 www.paradigmusa.com

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text

FULLY SPRINKLERED

AutoCAD SHX Text

REPLACE FIRE ALARM SYSTEM

AutoCAD SHX Text 614-19-111

AutoCAD SHX Text 06-24-2020

AutoCAD SHX Text

1030 JEFFERSON AVE, MEMPHIS, TN 38104

AutoCAD SHX Text

MEMPHIS VA MEDICAL CENTER

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

KEY PLAN - GROUND FLOOR

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100C

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100B

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100C

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100B

AutoCAD SHX Text GENERAL NOTES A. REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, SCHEDULES AND GENERAL NOTES. B. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATE AT EACH FIRE ALARM DEVICE. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION BOX AT EACH FIRE ALARM DEVICE INDICATED ON FLOOR PLANS. D. THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" CONDUIT FROM EACH FIRE ALARM DEVICE TO NEW FACP OR NAC PANELS. E. CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT SHALL NOT BE ALLOWED. F. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATES AT EACH FIRE ALARM DEVICE. G. THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM CONDUIT SYSTEM RED IN COLOR. H. ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT (ELECTRICAL METALLIC TUBING). I. ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE RIGID STEEL, NON-METALLIC TUBING SHALL NOT BE PERMITTED. J. THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND PATCHING ON ALL WALL OR CEILING OPENINGS. K. THE FIRE ALARM CONTRACTOR SHALL INSTALL CLASS 7, STYLE THE FIRE ALARM CONTRACTOR SHALL INSTALL CLASS 7, STYLE B WIRING SYSTEM THROUGHOUT. L. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY ENGINEERED SHOP DRAWINGS SUBMITTALS OF THE PROPOSED WORK PRIOR TO BEGINNING CONSTRUCTION. THE SHOP DRAWING SUBMITTALS SHALL INCLUDE BUT NOT LIMITED TO: VOLTAGE DROP CALCULATIONS, BATTERY CALCULATIONS, INSULATION VALUE, LENGTH OF WIRE, SLC WIRING DIAGRAM, NAC WIRING DIAGRAM ETC. M. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE PARADIGM ENGINEERING COMPLETED COORDINATION DRAWINGS AT CONCLUSION OF PROJECT, PARADIGM ENGINEERING WILL BEGIN AS-BUILT DRAWINGS WITHOUT COMPLETED COORDINATION DRAWINGS FROM CONTRACTOR. M. REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND VOLT DROP CALCULATIONS. N. REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER DIAGRAM.

AutoCAD SHX Text THE EXISTING CEILING GRID SYSTEM IS EXISTING TO REMAIN. THE CONTRACTOR SHALL REMOVE TILE AS REQUIRED TO INSTALL NEW CONDUIT. THE REMOVAL OF CEILING TILE AND INSTALLATION OF CONDUIT SHALL BE COORDINATED WITH VAMC AND SHALL COMPLY WITH INFECTION CONTROL STANDARDS SET BY THE VAMC. REFER REFER TO FLOOR PLAN FOR ROUTING OF NEW CONDUIT AND CIRCUITING INFORMATION.

AutoCAD SHX Text

CEILING WORK NOTE

AutoCAD SHX Text A7

SCOPE OF WORK:: A. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE ALARM DEVICES THROUGHOUT, UNLESS NOTED OTHERWISE. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. B. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW CONDUIT AND FIRE ALARM CABLING THROUGHOUT, REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR MODULES AS INDICATED ON FLOOR PLANS TO EXISTING TO REMAIN FIRE ALARM DEVICES. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. D. THE FIRE ALARM CONTRACTOR SHALL USE TAMPER THE FIRE ALARM CONTRACTOR SHALL USE TAMPER PROOF SCREWS THROUGHOUT. E. THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT (ELECTRICAL METALLIC TUBING) WHEN INSTALLING CONDUIT INDOORS. F. THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID ALUMINUM OR RIGID STEEL WHEN INSTALLING CONDUIT OUTDOORS.

151412 1311 18.818.417.517.116.215.314.914.113.112.811.911.110.6

W

V

U

T

S

R

Q

V.8

U.7

9.79.3 109.89.2

UNION

AEG 21

TOILET

AEG 63

STAFF

TOILET

AEF 40

CORRIDOR

SIMULATOR

AEG 55

AEG 57

CORRIDOR

RESEARCH LAB

AEG 9

RECEPTION

AEG 54

NURSES

AEG 60

CORRIDOR

CORRIDOR

WAITING

AEG 7

EXAM-R

AEG 51

IRM

AEG 4

RESEARCH FILE

STORAGE

AEG 9A

RESEARCH LAB

AEG 9C

EXAM-E

AEG 50

PAT TOILET

AEG 48

EXAM-S

AEG 46

EXAM-E

AEG 47

CORRIDOR

CORRIDOR

MAZE

ACCELERATOR

AEG 73

EQUIP

AEG 73A

CONTROL

FILM

VIEWING

AEG 72

BLOCK

CUTTING

AEG 71

DARK ROOM

AEG 67

MD

AEG 68

BREAK RM

AEG 69

REC/STO

AEG 70

ENGG CORRIDOR

AEG-C1

CAD DRAFTING

AEG 30A

PLAN RM

AEG 30

STORAGE

ENG TECH

AEG 28

OFFICE

AEG 26

OFFICE

AEG 24

CHIEF TECH

AEG 62

CORRIDOR

SECY

AEG 45

ADMIN

ASST

AEG 44

CHIEF

OF SVC

AEG 43

CONFERENCE RM

AEG 39

STOR

AEG 38

AEG 41

PHYSICS

AEG 37

SERVER

AEG 35

AEG 36

CORRIDOR

EXISTING

MECH RM

AEG 33

AEG 22

SIGN

SHOP

AEG 20

AEG 20E

AEG 18

HAC

AEG 16

AEG 11A

WOMEN

TOILET

AEG 14

MENS

TOILET

AEG 12

CONFERENCE RM

AEG 11

AEG 10A

AFGE

AEG 10

WORK ORDER

AEG 17A

AEG 15D

ENG TRAINEE

AEG 17B

SECY

AEG 17

COPIER

AEG 19A

ASST. CHIEF

AEG 17C

OFFICE

AEG 19B

CONFERENCE OFFICE

AEG 19

OFFICE

AEG 19C

IRM COMPUTER

SHOP

AEG 23

MECH EQUIP RM

AEG 32

STAIR 9

BIO MED

AEG 15

OFFICE

AEG 15B

OFFICE

AEG 15AEQUIP

MECH RM

AEG 13

BIO MED

EQUIP

AEG 18A

STAIR

NO - 8

AWG 18B

F1:L5:198

F1:L5:204

S F1:L5:199

F1:N8:03 F1:S8:02 15cd 0.5w

F1:N8:04 F1:S8:03 15cd 0.5w

F1:N8:07 F1:S8:05 15cd 0.5w

F1:N8:10 F1:S8:08 15cd 0.5w

F1:N8:15 F1:S8:13 15cd 0.5w

F1:N8:16 EOL

F1:S8:14 EOL

15cd 0.5w

F1:N8:12 F1:S8:10 15cd 0.5w

F1:N8:09 F1:S8:07 15cd 0.5w

F1:S15:37

PS6:N4:02

15cd 0.5w

F1:S15:39 EOL

PS6:N4:05 EOL 4.7k

15cd 0.5w

F1:N8:06 F1:S8:04 15cd 0.5w

F1:N11:01 F1:S11:01 15cd 0.5w

F1:N11:02 F1:S11:02 15cd 0.5w

F1:N11:10 F1:S11:08 15cd 0.5w

F1:N11:05 F1:S11:05 15cd 0.5w

F1:N11:14 EOL

F1:S11:14 EOL

15cd 0.5w

F1:N11:07 15cd

F1:N11:08 15cd

F1:N8:11 15cd

F1:N8:13 15cd

F1:N8:05 15cd

PS6:N4:04

15cd

F1:N8:14 F1:S8:11 15cd 0.5w

F1:N8:08 F1:S8:06 15cd 0.5w

F1:N11:06 F1:S11:06 15cd 0.5w

F1:N11:09 F1:S11:07 15cd 0.5w

F1:N11:11 F1:S11:09 15cd 0.5w

F1:N11:12 F1:S11:12 15cd 0.5w

F1:N11:13 F1:S11:13 15cd 0.5w

F1:N11:03 F1:S11:03 15cd 0.5w

TS

S F1:L5:201

S F1:L5:202

TS

FS

DH

F1:N11:04 F1:S11:04 15cd 0.5w

AIM

F1:L5:205 D

AIM

F1:L5:200

S

F1:S7:08 EOL

0.5w

S F1:S8:12 0.5w

S

F1:S8:09 0.5w

S

F1:S11:10 0.5w

S

F1:S11:11 0.5w

TS AIM

F1:L5:203

WORK ROOM

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Architecture Engineering Design-Build paradigm

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text

1.FA100B

AutoCAD SHX Text

KMB

AutoCAD SHX Text

NEW FIRE ALARM PLAN BUILDING 1 GROUND FLOOR AREA B

AutoCAD SHX Text

WLM

AutoCAD SHX Text F1

AutoCAD SHX Text

SCALE 1/8'' = 1'-0''

AutoCAD SHX Text

NEW FIRE ALARM PLAN BUILDING NO. 1 - GROUND FLOOR AREA "B"

AutoCAD SHX Text N

AutoCAD SHX Text 200 Envoy Circle, Suite 201, Louisville, KY 40299 www.paradigmusa.com

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text

FULLY SPRINKLERED

AutoCAD SHX Text

REPLACE FIRE ALARM SYSTEM

AutoCAD SHX Text 614-19-111

AutoCAD SHX Text 06-24-2020

AutoCAD SHX Text

1030 JEFFERSON AVE, MEMPHIS, TN 38104

AutoCAD SHX Text

MEMPHIS VA MEDICAL CENTER

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100D

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100A

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100D

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100A

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

KEY PLAN - GROUND FLOOR

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text F1

AutoCAD SHX Text GENERAL NOTES A. REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, REFER TO SHEET FA001 FOR LEGEND, ABBREVIATIONS, SCHEDULES AND GENERAL NOTES. B. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATE AT EACH FIRE ALARM DEVICE. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION THE FIRE ALARM CONTRACTOR SHALL PROVIDE NEW JUNCTION BOX AT EACH FIRE ALARM DEVICE INDICATED ON FLOOR PLANS. D. THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" THE FIRE ALARM CONTRACTOR SHALL ROUTE NEW 3/4" CONDUIT FROM EACH FIRE ALARM DEVICE TO NEW FACP OR NAC PANELS. E. CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT CONDUIT SYSTEM SHALL BE 3/4" MINIMUM. 1/2" CONDUIT SHALL NOT BE ALLOWED. F. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER THE FIRE ALARM CONTRACTOR SHALL PROVIDE FINISH COVER PLATES AT EACH FIRE ALARM DEVICE. G. THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM THE FIRE ALARM CONTRACTOR SHALL PAINT NEW FIRE ALARM CONDUIT SYSTEM RED IN COLOR. H. ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT ALL NEW CONDUITS INSTALLED INSIDE SHALL BE EMT (ELECTRICAL METALLIC TUBING). I. ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDING SHALL BE RIGID STEEL, NON-METALLIC TUBING SHALL NOT BE PERMITTED. J. THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND THE FIRE ALARM CONTRACTOR SHALL PROVIDE CUTTING AND PATCHING ON ALL WALL OR CEILING OPENINGS. K. THE FIRE ALARM CONTRACTOR SHALL INSTALL CLASS 7, STYLE THE FIRE ALARM CONTRACTOR SHALL INSTALL CLASS 7, STYLE B WIRING SYSTEM THROUGHOUT. L. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY THE FIRE ALARM CONTRACTOR SHALL PROVIDE FULLY ENGINEERED SHOP DRAWINGS SUBMITTALS OF THE PROPOSED WORK PRIOR TO BEGINNING CONSTRUCTION. THE SHOP DRAWING SUBMITTALS SHALL INCLUDE BUT NOT LIMITED TO: VOLTAGE DROP CALCULATIONS, BATTERY CALCULATIONS, INSULATION VALUE, LENGTH OF WIRE, SLC WIRING DIAGRAM, NAC WIRING DIAGRAM ETC. M. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE PARADIGM ENGINEERING COMPLETED COORDINATION DRAWINGS AT CONCLUSION OF PROJECT, PARADIGM ENGINEERING WILL BEGIN AS-BUILT DRAWINGS WITHOUT COMPLETED COORDINATION DRAWINGS FROM CONTRACTOR. M. REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND REFER TO DRAWING FA516.1 AND FA517.1 FOR BATTERY AND VOLT DROP CALCULATIONS. N. REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER REFER TO DRAWING FA501.1-FA515.1 FOR FIRE ALARM RISER DIAGRAM.

AutoCAD SHX Text THE EXISTING CEILING GRID SYSTEM IS EXISTING TO REMAIN. THE CONTRACTOR SHALL REMOVE TILE AS REQUIRED TO INSTALL NEW CONDUIT. THE REMOVAL OF CEILING TILE AND INSTALLATION OF CONDUIT SHALL BE COORDINATED WITH VAMC AND SHALL COMPLY WITH INFECTION CONTROL STANDARDS SET BY THE VAMC. REFER REFER TO FLOOR PLAN FOR ROUTING OF NEW CONDUIT AND CIRCUITING INFORMATION.

AutoCAD SHX Text

CEILING WORK NOTE

AutoCAD SHX Text A7

SCOPE OF WORK:: A. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW FIRE ALARM DEVICES THROUGHOUT, UNLESS NOTED OTHERWISE. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. B. THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW THE FIRE ALARM CONTRACTOR SHALL INSTALL NEW CONDUIT AND FIRE ALARM CABLING THROUGHOUT, REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR THE FIRE ALARM CONTRACTOR SHALL PROVIDE MONITOR MODULES AS INDICATED ON FLOOR PLANS TO EXISTING TO REMAIN FIRE ALARM DEVICES. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. D. THE FIRE ALARM CONTRACTOR SHALL USE TAMPER THE FIRE ALARM CONTRACTOR SHALL USE TAMPER PROOF SCREWS THROUGHOUT. E. THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT THE FIRE ALARM CONTRACTOR SHALL INSTALL EMT (ELECTRICAL METALLIC TUBING) WHEN INSTALLING CONDUIT INDOORS. F. THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID THE FIRE ALARM CONTRACTOR SHALL INSTALL RIGID ALUMINUM OR RIGID STEEL WHEN INSTALLING CONDUIT OUTDOORS.

N

L

M

J

K

P5

P4

P2

P1

P

P3

ELEC SHOP STORAGE

BWG 25

STORAGE

CORRIDOR

BW-C6

CORRIDOR

BW-C22

FITNESS CENTER

AWG 3

CORRIDOR

BW C 31A

WOMENS LOCKER RM

AWG 13

TOILETS AND

SHOWERS

AWG 11A

FEMALE

LOUNGE

AWG 11

STAIR 5

LOCK SMITH

STORAGE

AWG 9

OFFICE

CWG 15A

OFFICE

CWG 20A

OFFICE

CWG 20

HAC

CWG 14

OFFICE

BWG 4A

BWG 4D

ELEC

CLOSET

BWG 4E

ELEVATOR

RADIOLOGY / X-RAY FILE RM

BWG 2

X-RAY

STORAGE

BWG 2A

GRAPHIC CONTROL

BWG 1A

MECH RM

BWG 1

MECH RM

BWG 1

SCREENING

CWG 7A

OFFICE

CWG 7B

CYTOLOGY

CWG 7

CORRIDOR

BW C 2

CORRIDOR

BW C 28

CORRIDOR

BW C 29

CORRIDOR

BW C 30

CLERICAL

SEC/WAIT

BW G 33

CHIEF

BW G 33B

ASST

BW G 33A

WORK RM

BW G 33C

CONSULT

BW G 32

PHARM

BW G 31

OFFICE

BW G 30

OFFICE

BW G 29

STUDY

BW G 26

CARE OFFICE

BW G 27

CONF

BW G 28

OFFICE

CWG 6B

SHAFT

FRAM

STOR

CWG 6A

REFRIGERANT

STORAGE

BWG 24B

REFRIGERANT

STORAGE

BWG 24A

AC SHOP STORAGE

BWG 24

PARAFFIN

STORAGE

CWG 4

AUTOPSY

CWG 2

S

F1:L4:140

S

F1:L4:141

S

F1:L4:131

S

F1:L4:138

F1:S15:36

PS6:N4:01

15cd 0.5w

F1:S15:35

PS6:N3:01

15cd 0.5w

F1:S15:32

PS6:N3:05

15cd 0.5w

F1:S15:29 PS6:N3:09 EOL 4.7k 15cd 0.5w

F1:S15:30

PS6:N3:08

15cd 0.5w

F1:S15:31

PS6:N3:07

15cd 0.5w

F1:N10:01 F1:S10:01 15cd 0.5w

F1:S15:23

PS6:N1:09

15cd 0.5w

F1:S15:28

PS6:N1:12 EOL

15cd 0.5w

F1:S15:27

PS6:N1:11

15cd 0.5w

F1:S15:02

PS6:N2:12

75cd 0.5w

F1:S15:03

PS6:N2:11

75cd 0.5w

F1:S15:01 PS6:N2:13 EOL 4.7k 75cd 0.5w

F1:S15:08

PS6:N2:06

75cd 0.5w

F1:S15:21

PS6:N1:07

75cd 0.5w

F1:S15:16

PS6:N1:03

75cd 0.5w

F1:S15:25

PS6:N1:10

15cd 0.5w

F1:S15:14

PS6:N1:01

15cd 0.5w

F1:S15:13

PS6:N2:01

30cd 0.5w

F1:N2:02 F1:S2:02 75cd 0.5w

F1:S15:05

PS6:N2:09

15cd 0.5w

F1:S15:06

PS6:N2:08

15cd 0.5w

F1:S15:07

PS6:N2:07

15cd 0.5w

F1:S15:04

PS6:N2:10

15cd 0.5w

F1:S15:09

PS6:N2:05

15cd 0.5w

F1:S15:10

PS6:N2:04

75cd 0.5w

F1:S15:11

PS6:N2:03

75cd 0.5w

F1:S15:12

PS6:N2:02

75cd 0.5w

F1:S15:22

PS6:N1:08

15cd 0.5w

PS6:N3:06

15cd

F1:S15:15

PS6:N1:02

15cd 0.5w

F1:N4:01 F1:S4:01 15cd 0.5w

F1:N3:01 F1:S3:01 15cd 0.5w

TS

FS

TSTS

TS

F1:L4:132

AIM

F1:L4:128 4-I/0

AIMF1:L4:129

S

F1:S15:24 0.5wS

F1:S15:26 0.5w

S F1:S15:17 0.5w

S

F1:S3:02 0.5w

S F1:L4:143

AIM D

F1:L4:157FS

TS

AIM F1:L4:130

D

FS

TS

FS

F1:N2:01 F1:S2:01 75cd 0.5w

DH

DH

AOM F1:L4:139

ELEVATOR #P8 & P9 SHUNT TRIP

ANSUL AIM

F1:L4:144

NAC

PS6

FACP

F1

S F1:L4:143

AIM

F1:L4:142

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Architecture Engineering Design-Build paradigm

AutoCAD SHX Text F

AutoCAD SHX Text

1.FA100C

AutoCAD SHX Text

KMB

AutoCAD SHX Text

WLM

AutoCAD SHX Text F3

AutoCAD SHX Text N

AutoCAD SHX Text 200 Envoy Circle, Suite 201, Louisville, KY 40299 www.paradigmusa.com

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text

FULLY SPRINKLERED

AutoCAD SHX Text

REPLACE FIRE ALARM SYSTEM

AutoCAD SHX Text 614-19-111

AutoCAD SHX Text 06-24-2020

AutoCAD SHX Text

1030 JEFFERSON AVE, MEMPHIS, TN 38104

AutoCAD SHX Text

MEMPHIS VA MEDICAL CENTER

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100A

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100D

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100A

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100D

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100E

AutoCAD SHX Text

MATCHLINE - REFER TO 1.FA100E

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

KEY PLAN - GROUND FLOOR

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text F3

AutoCAD SHX Text

SCALE 1/8'' = 1'-0''

AutoCAD SHX Text

NEW FIRE ALARM PLAN BUILDING NO. 1 - GROUND FLOOR AREA "C"

AutoCAD SHX Text

NEW FIRE ALARM PLAN BUILDING 1 GROUND FLOOR AREA C

AutoCAD SHX Text GENERAL NOTES A.