S02 BD03252022 Drawings - 9_Security Electronics.pdf
PDF 2 MB Posted
- Attached to
- Y1NB--650-19-100 Replace Boilers in Bldg 10 Federal contract opportunity
- Solicitation number
- 36C24122R0084
About this file
This request for proposal from the Department of Veterans Affairs solicits bids to replace boilers in Building 10 at a VA medical center. The RFP requires contractors to remove and replace two existing steam boilers with new high-efficiency condensing boilers and associated equipment. Bidders must provide all necessary design, permitting, equipment, installation, and commissioning. The contract award date is scheduled for July 2022, with work to be completed by January 2023. Pricing shall be fixed for the base year with option years for maintenance. The solicitation is unrestricted and open to all responsible sources.
View the file
Other files for this federal contract opportunity
Show all 50
Y1NB--650-19-100 Replace Boilers in Bldg 10 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BIOMETRICS ACCESS CONTROL DEVICE; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
F-FINGER PRINT H-HAND GEOMETRY I-EYE IRIS
R-EYE RETINA V-VOICE
CARD ACCESS READER; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
B-BARCODE F-ELEVATOR FLOOR CALL H-ELEVATOR HALL CALL
M-MAG STRIP P-PROXIMITY S-SMART CARD
CARD READER WITH KEYPAD; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
CENTRAL PROCESSING UNIT
CONTROL PANEL; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
B-BURGLAR D-DOOR F-FIRE P-PERIMETER
ELECTRONIC LOCK; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
D-DEADBOLT H-HYBRID L-LATCH SET M-MAGNETIC S-STRIKE
EXIT DEVICE; LETTER INDICATES AS FOLLOWS:
T=TECHNOLOGY/TYPE
D-DELAYED EGRESS E-ELECTRIFIED M-MECHANICAL X-HIGH SECURITY
FIBER OPTIC MODULE; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
R-RECEIVER T-TRANSCEIVER TX-TRANSMITTER
FIELD PANEL; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
A-ALARM C-CARD READER
INTERCOM; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
M-MASTER S-SUBSTATION
KEYBOARD
KEYPAD DEVICE; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
MONITOR; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
D-DATA G-GRAPHIC M-MULTISCREEN V-VIDEO
MOTION DETECTOR; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
D-DUAL TECHNOLOGY IR-INFRARED M-MICROWAVE U-ULTRASONIC
X-REQUEST-FOR-EXIT
ELECTRONIC SAFETY AND SECURITY SYMBOLS
PUSH BUTTON; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
B-BELL PUSH D-DURESS P-PANIC R-DOOR RELEASE
X-REQUEST-FOR-EXIT
M
T
M
T
T
M
M
M
T
T
M
T
M
T
M
T
M
M
T
M
T
M
T
RECORDER; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
A-AUDIO D-DIGITAL V-VIDEO
SECURITY ACCESS, ANNUNCIATOR PANEL
SECURITY ACCESS, BUZZER. MTD 1'-6" [457mm] AFF UNLESS OTHERWISE NOTED
SECURITY ACCESS, CONTROL UNIT WITH CLOSED CIRCUIT TELEVISION
CAMERA
SECURITY ACCESS, GENERIC "X" INDICATES THE TYPE, PROVIDE SCHEDULE OR LEGEND
SECURITY ACCESS, HORN OR SIREN
SECURITY ACCESS, OUTDOOR MICROWAVE TRANSMISSION UNIT
SECURITY ACCESS, PANIC ALARM
SECURITY ACCESS, VIDEO CAMERA WITH LENS
M = MOTION DETECTOR
PZ = MOTION DETECTOR WITH PAN AND ZOOM
PTZ= MOTION DETECTOR WITH PAN, TILT, AND ZOOM
SECURITY ACCESS, VOLUMETRIC SENSOR
VIDEO CONTROL KEYBOARD
VIDEO MOTION DETECTOR
SECURITY ACCESS, MULTI-SENSOR/PANORAMIC VIEW, ANGLE OF VIEW
SECURITY ACCESS, SENSOR, BURIED VEHICULAR
SECURITY ACCESS, SWITCH, BALANCED MAGNETIC CONTROL
SECURITY ACCESS, TELEPHONE HANDSET
SECURITY ACCESS, VIDEO CAMERA WITH LENS, ANGLE OF VIEW
360°
40°
X
M PTZ
M
T
AP
SECURITY ACCESS, DOOR PROP/EXIT ALARMDA
SECURITY ACCESS, INTERFACE RELAY SWITCH
1PH SINGLE-PHASE
1P SINGLE POLE
2/C TWO-CONDUCTOR
3/C THREE-CONDUCTOR
3PH THREE-PHASE
4/C FOUR-CONDUCTOR
4W FOUR-WIRE
A/E ARCHITECT/ENGINEER
AAP ALARM ANNUNCIATOR PANEL
AC ALTERNATING CURRENT OR
ARMORED CABLE
ADA AMERICANS WITH DISABILITIES ACT
ADDL ADDITIONAL
ADJ ADJACENT, ADJOINING
ADO AUTOMATIC DOOR OPENER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
ALT ALTERNATE
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
BAT BATTERY
BFF BELOW FINISH FLOOR
BLDG BUILDING
BPIP BOILER PLANT INSTRUMENTATION PANEL
C CONDUIT
CATV COMMUNITY ANTENNA TELEVISION
CCR CONTROL CONTACTOR
CD CONSTRUCTION DOCUMENTS
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER
INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CLG CEILING
CMU CONCRETE MASONRY UNIT
COAX COAX CABLE
COMM COMMUNICATION
CONT CONTINUE
CONTR CONTRACTOR
CTV CABLE TELEVISION
CU COPPER
CU FT CUBIC FEET
DB DECIBEL OR DIRECT BURIAL
DC DIRECT CURRENT
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLITION
DIAG DIAGRAM
DRSW DOOR SWITCH
EC EMPTY CONDUIT
EG EQUIPMENT GROUND
EL ELEVATION
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
EPO EMERGENCY POWER OFF
ESMT EASEMENT
EXIST EXISTING
FLEX FLEXIBLE METALLIC CONDUIT
FT FEET OR FOOT
ELECTRONIC SAFETY AND SECURITY ABBREVIATIONS
GND GROUND
GEN GENERATOR
GTB GROUND TERMINAL BOX
HOA HAND-OFF-AUTOMATIC
HZ HERTZ
IMC INTERMEDIATE METAL CONDUIT
IR INFRARED
J-BOX JUNCTION BOX
LF LINEAR FEET (FOOT)
LTNG LIGHTNING
LV LOW VOLTAGE
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MECH MECHANICAL
MH MANHOLE
MIN MINIMUM
MT MOUNT
MTD MOUNTED
MTG MOUNTING
NA NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
N NEUTRAL
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
P POLE
PA PUBLIC ADDRESS
PB PANELBOARD, PULL BOX, OR
PUSHBUTTON
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
RCP REFLECTED CEILING PLAN
RECPT RECEPTACLE
RGS RIGID GALVANIZED STEEL
RM ROOM
REQD REQUIRED
SF SQUARE FOOT (FEET)
SI INTERNATIONAL SYSTEM OF UNITS
SSTV SECURITY SURVEILLANCE TELEVISION
SW SWITCH
TEL TELEPHONE
TP TWISTED PAIR
TPS TWISTED PAIR SHIELDED
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
TYP TYPICAL
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLT
WP WEATHERPROOF
A. REFER TO E-001 FOR ELECTRICAL LEGEND, GENERAL NOTES, AND ABBREVIATIONS.
B. THE MINIMUM STANDARD FOR ALL WORK SHALL BE THE APPLICABLE CODES REFERENCED ON LIFE SAFETY PLAN, SHEET AE002. WHENEVER THE ENGINEERS DESIGN
REQUIRES A HIGHER STANDARD, THE HIGHER STANDARD DESIGN SHOWN SHALL BE FOLLOWED.
C. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, EQUIPMENT, AND TOOLS TO EXECUTE WORK DETAILED BY THE DRAWINGS AND PROJECT SPECIFICATIONS, AND SHALL PROVIDE A COMPLETELY OPERATIONAL CAMERA SURVEILLANCE/ELECTRICAL SYSTEM UPON COMPLETION OF THE PROJECT.
D. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF THE ELECTRICAL WORK WITH THAT OF OTHER TRADES. THE ELECTRICIAN IS RESPONSIBLE FOR MAKING
ALL ELECTRICAL CONNECTIONS TO THE EQUIPMENT REQUIRING ELECTRICAL POWER, REGARDLESS OF WHO FURNISHED OR INSTALLED IT.
E. THE CONTRACTOR IS RESPONSIBLE FOR DAILY CLEANUP OF ALL WORK AREAS DURING TERM PROJECT; AND FOR RETURNING TO ORIGINAL CONDITION UPON
COMPLETION OF ALL WORK INDICATED.
F. ALL ELECTRICAL WORK SHALL BE WARRANTED FOR ONE YEAR FROM THE DATE OF INSPECTION PUNCHLIST COMPLETION.
G. ALL MATERIALS USED SHALL BE NEW AND UL LISTED WHERE A LISTING EXISTS FOR THE PRODUCT.
H. ALL WIRING SHALL BE COPPER. ALUMINUM WIRING SHALL NOT BE ALLOWED. MINIMUM WIRE SIZE SHALL BE #12 AWG, CONDUCTORS SHALL BE THWN IN SMALLER
SIZES OR MAY BE THW IN LARGER SIZES IF ECONOMICAL, AND SHALL BE RATED 600 VOLTS. RUNS OF 120 VOLTS OVER 50 FEET SHALL UTILIZE #10 AWG TO
PREVENT EXCESSIVE VOLTAGE DROP. CONDUCTORS SHALL BE COLOR CODED AS REQUIRED BY THE NEC.
I. WIRING DEVICES SHALL BE SPEC GRADE, RATED 20 AMPERES. DEVICE PLATES SHALL BE SMOOTH FINISH IVORY NYLON.
J. CONDUIT CONCEALED IN WALLS OR CEILINGS SHALL BE EMT WITH TAMPER PROOF SCREWS, AND EXPOSED CONDUITS SHALL BE EMT WITH TAMPER PROOF SCREWS.
ALL CONDUITS SHALL HAVE AN EXTRA CONDUCTOR PULLED FOR GROUNDING. ALL CONDUIT SHALL BE CONCEALED, UNLESS SPECIFICALLY NOTED OTHERWISE. ALL
CONDUIT FITTINGS SHALL BE COMPRESSION TYPE. THE LAST PIECE OF CONDUIT INSTALLED TO EQUIPMENT SHALL BE FLEXIBLE METAL CONDUIT. MINIMUM
CONDUIT SIZE SHALL BE 3/4 INCH. CONDUITS SHALL BE INSTALLED AT RIGHT ANGLES TO CEILINGS, WALLS, AND STRUCTURAL MEMBERS. CONDUIT SHALL BE
SUPPORTED BY PIPE STRAPS, WALL BRACKETS, OR HANGERS. SPACER BACK CLAMPS SHALL BE UTILIZED IN MOIST OR WET AREAS.
K. HUBS SHALL BE USED ON BOXES WHERE CONDUIT ENTERS THE TOP AND IS EXPOSED TO WEATHER. SEALING LOCKNUTS MAY BE USED FOR SIDE ENTRY CONDUITS
IN THIS APPLICATION.
L. CONDUITS SHALL BE SEALED WHERE THEY ENTER THE BUILDING TO PREVENT GROUNDWATER ENTRY.
M. BOXES SHALL BE INSTALLED SUCH THAT THEY ARE SUPPORTED BY THE STRUCTURE. BOXES MAY NOT BE SUPPORTED BY CONDUIT.
N. IN THE ABSENCE OF DETAILS HEREIN ON USE OR INSTALLATION OF A PARTICULAR MATERIAL OR DEVICE, CODES AND MANUFACTURERS RECOMMENDATIONS SHALL BE
USED AS GUIDANCE.
O. IT IS HIGHLY RECOMMENDED THAT THE CONTRACTOR VISIT THE SITE PRIOR TO BIDDING, TO BECOME FAMILIAR WITH EXISTING CONDITIONS TO BE ENCOUNTERED
DURING CONSTRUCTION.
P. NOT ALL SYMBOLS INDICATED IN THE LEGEND, OR LISTED ABBREVIATIONS, APPEAR ON THE DRAWINGS. COORDINATE WORK ACCORDINGLY. COMPLY WITH
SPECIFICATIONS AND GENERAL NOTES AS APPLICABLE.
Q. ALL WORK SHALL COMPLY WITH LATEST EDITION OF NFPA70, NFPA72, NFPA99, NFPA101, NEC & ALL FEDERAL, STATE & LOCAL REGULATIONS.
R. ALL PENETRATIONS THROUGH FLOORS, RATED WALLS AND PARTITIONS SHALL BE SEALED WITH UL APPROVED FIRESTOPPING/SEALANT MATERIAL TO MAINTAIN THE
EXISTING FIRE RATING FOR THE ASSEMBLY.
S. AN EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED WITH ALL FEEDER AND BRANCH CIRCUITS. SIZE IN ACCORDANCE WITH NFPA 70 ARTICLE 250.
T. COORDINATE INSTALLATION AND FINAL LOCATION OF DATA OUTLETS WITH THE VA.
U. IDENTIFICATION:
RECEPTACLES CONNECTED TO THE ESSENTIAL ELECTRICAL SYSTEM SHALL BE RED WITH A WHITE LABEL CONTAINING THE WORD "EMERGENCY" IN BLACK ON THE
TOP OF THE PLATE AND A WHITE LABEL WITH THE CIRCUIT NUMBER IN BLACK ON THE BOTTOM. "NORMAL" RECEPTACLES SHALL HAVE A WHITE LABEL WITH THE
CIRCUIT NUMBER IN BLACK AT THE BOTTOM OF THE PLATE.
V. PROVIDE WIRE MARKERS TO IDENTIFY CABLES FOR ALL SYSTEMS AT THE ORIGIN, PULL BOXES, AND TERMINATION POINTS. LABELS SHALL BE SELF ADHESIVE OR
HEAT SHRINK TYPE AND BE PERMANENTLY AFFIXED TO THE WIRE BEING LABELED.
W. NO LIVE WORK WILL BE ALLOWED. EVERY CIRCUIT SHALL BE LOCKED-OUT AND TAGGED-OUT BEFORE COMMENCING WORK.
X. NO "J" HOOKS. (OR ANY OTHER TYPE OF WIRE "HANGING" SYSTEM IS PERMITTED WITHIN THE SCOPE OF THIS WORK FOR THE ENTIRE LENGTH OF WIRING RUNS
INDICATED.) REFER TO GENERAL NOTE "L".
Y. NEW CONDUIT RUNS SHOWN BY PLANS ARE DIAGRAMMATIC IN NATURE. CONTRACTOR SHALL INSTALL NEW CONDUITS IN CONCEALED LOCATIONS UNLESS SPECIFICALLY
NOTED OTHERWISE.
Z. MOST CONDUITS TO BE INSTALLED ABOVE EXISTING SUSPENDED ACOUSTICAL TILE (SAT) CEILINGS IN A MANNER THAT MINIMIZES DAMAGE TO EXISTING SAT
CEILINGS. REFER TO GENERAL NOTES SHEET E-002.
AA. TOTAL CONDUIT LENGTHS MAY NOT EXCEED 295'-0" FROM CAMERA LOCATION TO I.T. ROOM CONNECTION POINT.
AB. NEW CONDUITS SHALL BE SECURED TO EXISTING WALL CONSTRUCTION, EXISTING STRUCTURAL SYSTEM OR EXISTING PLASTER FINISHES CONCEALED FROM VIEW
(ABOVE SAT).
AC. CONTRACTOR SHALL TAKE MEASURES NECESSARY TO AVOID CONFLICTS WITH EXISTING MECHANICAL, ELECTRICAL AND PLUMBING (MEP) INFRASTRUCTURE AT NO
ADDITIONAL COST TO VAMC.
AD. VA INFORMATION TECHNOLOGY/SYSTEMS PERSONNEL WILL USE THE CONTRACTOR'S COMPLETED, LABELED AND INDEX LISTED CABLING TO PHYSICALLY MAKE THE
FINAL CONNECTION TO VAMC OWNED SWITCHES INSIDE OF IT ROOMS.
AE. INTRUSION DETECTION SYSTEMS (IDS), DURESS/PANIC SYSTEMS, PHYSICAL ACCESS CONTROL SYSTEMS (PACS), AND SURVEILLNACE TELEVISION (SSTV) DESIGN TO
FOLLOW VA PSRDM - CHAPTER 10, VA TDM 2016, AND NEC.
ELECTRONIC SAFETY AND SECURITY GENERAL NOTES:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t o n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t th re e in c h o n e fo o t
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502)836-4232
/1
/2
:0
:5
P
M
TY001
SECURITY ELECTRONICS
SYMBOLS AND GENERAL NOTES
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
1-07-2022 PJB PJB0506-0011
100% CORRECTED
CONSTRUCTION DOCUMENTS
NOT FOR CONSTRUCTION
FULLY SPRINKLERED
Revisions: Date:
RIP-RAP
ARBORVITAE HEDGE
ASPH.
ASPH.
ASPH.
EXISTING SIGN
NO PARKING SIGN
GU
AR
DR
AI
L
CO
NC
S
WL
K
EXISTING
ASPH
269°44'12"
85°11'50"
CONC BOUND FOUND
RD
BUILDING #10
BOILER PLANT
BUILDING #9
AIR FORCE DRIVE
LIMIT OF
DISTRUBANCE (TYP.)
BUILDING #11
WOOD
SHED
2 3
TE
M P O R A R Y
B O
IL
E R
C O N
TR
O L
R O O M
TR
A
IL
E R
TEMPORARY 650HP
STEAM GENERATION
TRAILER
TEMPORARY 650HP
STEAM GENERATION
TRAILER
BUILDING #7BUILDING #8
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502)836-4232
/1
/2
:0
:5
P
M
TY002
SECURITY ELECTRONICS
SITE STAGING PLAN
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
1-07-2022 PJB PJB0506-0011
100% CORRECTED
CONSTRUCTION DOCUMENTS
NOT FOR CONSTRUCTION
FULLY SPRINKLERED
SHEET KEYNOTES:
1 TEMPORARY GATE WITH MAGNETIC LOCK. PROVIDE CONDUIT/WIRING BACK TO POWER
SUPPLIES AND ASSOCIATED PHYSICAL ACCESS CONTROL PANEL. INSTALL SIMILAR TO DETAIL
6 ON SHEET TY501.
2 CARD READER PEDESTAL. REFER TO PEDESTAL DETAILS ON SHEET TY502.
3 ALL PHYSICAL ACCESS CONTROL DEVICES SHALL BE WEATHERPROOF (IP66 RATED).
4 COORDINATE MOUNTING OF REX PUSHBUTTON WITH LOCATION OF THE TEMPORARY CONTROL
BUILDING AND BOILER TRAILERS.
SCALE: 1" = 10'
SECURITY ELECTRONICS - SITE STAGING PLAN PLAN
NORTH
ACTUAL
NORTH
GENERAL NOTES:
1 ALL SECURITY ELECTRONICS CABLING SHALL BE INSTALLED IN CONDUIT.
2 WHERE POSSIBLE, UTILIZE THE TEMPORARY PIPE SUPPORTS FROM THE MOBILE BOILER PLANT
TRAILERS TO EXISTING BUILDING 10 (REFER TO SHEET MC101 FOR PIPE SUPPORT
LOCATIONS). OTHERWISE, CONDUIT SHALL BE INSTALLED UNDERGROUND.
3 LOCATE ALL EXISTING UNDERGROUND UTILITES FOR ALL UNDERGROUND WORK PRIOR TO
EXCAVATION OR TRENCHING. HAND DIG WITHIN 10' OF AN UTILITY CROSSING WITH NEW
WORK.
4 MINIMUM BURY FOR ALL SITE CONDUITS SHALL BE 40", UNLESS OTHERWISE NOTED.
CONTRACTOR IS RESPONSIBLE FOR ALL SITE TRENCHING AND BACKFILL.
5 REFER TO CIVIL DRAWINGS FOR ADDITIONAL INFORMATION.
6 REFER TO SHEETS TY601 THRU TY603 FOR PHYSICAL ACCESS CONTROL SYSTEM RISER
DIAGRAMS.
7 REFER TO SHEETS TY501 AND TY502 FOR PHYSICAL ACCESS CONTROL SYSTEM DETAILS.
8 DEVICES ON THIS SHEET ARE FOR TEMPORARY USAGE, PROVIDE CONNECTION TO THE
EXISTING SECURITY NETWORK VIA EXISTING OR NEW PHYSICAL ACCESS SYSTEM CONTROL
PANEL.
9 AFTER USE OF THE TEMPORARY CONTROL BUILDING AND BOILERS, CONTRACTOR SHALL
REMOVE THE PHYSICAL ACCESS CONTROL DEVICES AND TURN DEVICES OVER TO OWNER.
RIM = 79.11
EX
IS
TI
NG
C
ON
C R
ET
W
AL
L
EX
IS
TI
NG
GR
AN
C
UR
B
E
W M
0°
BUILDING #10
BOILER PLANT
BUILDING #9
1 2 3 4 5
TYP.
1 2
TYP.
WATER STORAGE
TANK
61 2
AIR FORCE DRIVE
AP1
LIMITS OF NEW
CONCRETE AND
ASPHALT PAVEMENT
VISITOR ENTRANCE
EMPLOYEE ENTRANCE
8 9 1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502)836-4232
/1
/2
:0
:5
P
M
TY003
SECURITY ELECTRONICS
SITE PLAN
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
1-07-2022 PJB PJB0506-0011
100% CORRECTED
CONSTRUCTION DOCUMENTS
NOT FOR CONSTRUCTION
FULLY SPRINKLERED
SHEET KEYNOTES:
1 SLIDING GATE OPERATOR.
2 CONTRACTOR SHALL PROVIDE ALL CONDUIT/CABLING REQUIRED FOR SAFETY PHOTO EYE
SENSORS (LEADING AND TRAILING END), VEHICULAR LOOPS, ETC. COORDINATE WITH
APPROVED SLIDING GATE OPERATOR SUBMITTAL.
3 DUAL CARD READER/INTERCOM ENTRY PEDESTAL. REFER TO PEDESTAL DETAILS ON SHEET
TY502.
4 INTERCOM ENTRY PEDESTAL. REFER TO PEDESTAL DETAILS ON SHEET TY502.
5 PROVIDE PROTECTIVE BOLLARD. SIMILAR TO DETAIL 9, SHEET C501.
6 INSTALL VEHICULAR LOOP AND CONNECTION TO ASSOCIATED GATE OPERATOR.
7 POLE MOUNTED CAMERA. REFER TO DETAILS ON SHEET TY504 FOR ADDITONAL
INFORMATION.
8 PROVIDE 5C #22 AWG (CARD READER) AND CAT 6A UTP (INTERCOM/VIDEO STATION)
CABLES BACK TO ASSOCIATED PHYSICAL ACCESS CONTROL PANEL AND INTERCOM RACK
(SECURITY ROOM 206 - BOILER LEVEL - SHEET TY102).
9 PROVIDE CAT 6A UTP (INTERCOM/VIDEO STATION) CABLE BACK TO INTERCOM RACK
(SECURITY ROOM 206 - BOILER LEVEL - SHEET TY102).
10 SLIDE GATE CONTROL (ACCESS CONTROL) - 2#12, 1#12 GND FROM GATE OPERATOR TO
ASSOCIATED PHYSICAL ACCESS CONTROL PANEL (SECURITY ROOM 206 - BOILER LEVEL -
SHEET TY102).
11 SLIDE GATE CONTROL (INTERCOM RELEASE) - 2#12, 1#12 GND FROM INTERCOM/VIDEO
STATION TO GATE OPERATOR.
12 PROVIDE CAT 6A UTP (CAMERA) CABLE BACK TO VIDEO SURVEILLANCE RACK (SECURITY
ROOM 206 - BOILER LEVEL - SHEET TY102).
SCALE: 1" = 10'
SECURITY ELECTRONICS - SITE PLAN
GENERAL NOTES:
1 CONTRACTOR SHALL PROVIDE 12-STRAND SINGLEMODE (OS2) OPTICAL FIBER (ASSOCIATED
WITH THE VA'S VIDEO SURVEILLANCE CAMPUS WIDE NETWORK) FROM EXISTING IT ROOM IN
BUILDING 14 TO SECURITY ELECTRONICS EQUIPMENT RACK (SECURITY ROOM 206 - BOILER
LEVEL - SHEET TY102). REFER TO CONDUIT/ DUCT BANK ROUTING SHOWN ON ELECTRICAL
DRAWINGS ES101, E-100, AND E-402.
2 ALL SECURITY ELECTRONICS CABLING SHALL BE INSTALLED IN CONDUIT. REFER TO
ELECTRICAL SITE PLAN, ES102 FOR CONDUIT/DUCT BANK ROUTING FROM DEVICES/
EQUIPMENT TO BUILDING 10.
3 LOCATE ALL EXISTING UNDERGROUND UTILITIES FOR ALL UNDERGROUND WORK PRIOR TO
EXCAVATION OR TRENCHING. HAND DIG WITHIN 10' OF AN UTILITY CROSSING WITH NEW
WORK.
4 MINIMUM BURY FOR ALL SITE CONDUITS SHALL BE 40", UNLESS OTHEWISE NOTED.
CONTRACTOR IS RESPONSIBLE FOR ALL SITE TRENCHING AND BACKFILL.
5 REFER TO CIVIL DRAWINGS FOR ADDITIONAL INFORMATION.
6 REFER TO SHEETS TY601 THRU TY603 FOR PHYSICAL ACCESS CONTROL SYSTEM RISER
DIAGRAMS.
7 REFER TO SHEETS TY501 AND TY502 FOR PHYSICAL ACCESS CONTROL SYSTEM DETAILS.
8 REFER TO SHEET TY604 FOR INTERCOM SYSTEM RISER DIAGRAM.
9 REFER TO SHEETS TY605 AND TY606 FOR VIDEO SURVEILLANCE SYSTEM RISER DIAGRAM.
10 REFER TO SHEET TY504 FOR CAMERA POLE AND MOUNT DETAILS.
PLAN
NORTH
ACTUAL
NORTH
M
M
M M
MAINTENANCE
LOCKERS
RESTROOM
SHOWER
OFFICE
BREAK ROOM
MAINTENANCE - ADDITION
ANNEX
S
S
M
S
M S
X
S
X S
102A
101A
102B
S2 S3 S4
S13
E1
S1
TRANSFORMER
109A
109B
F
X
M
F
F
F
M M
F FF
6.7 76 8 9 10
54.94321
A
A.1
A.2
B
B.1
B.2 B.4
C
C.7
D
D.1
E
DD
CC
B.3
BB
X
S
X S
X F
F
X
4 3 3
S
S
S
S
M
M S
S S
S
M M
S S
S
X
S
BE1
BE3
BE5
BE4
X
M
X F
S
F
F
DA
DA
DA
DA
DA
DA
DA
BE2
X S
S
SS
M
W
D
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
PLAN
NORTH ACTUAL
NORTH
KEYPLAN
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502)836-4232
/1
/2
:0
:5
P
M
TY101
SECURITY ELECTRONICS
MAIN LEVEL
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
1-07-2022 PJB PJB0506-0011
100% CORRECTED
CONSTRUCTION DOCUMENTS
NOT FOR CONSTRUCTION
FULLY SPRINKLERED
SCALE: 1/4" = 1'-0"
SECURITY ELECTRONICS - MAIN LEVEL
SHEET KEYNOTES:
1 DOUBLE DOOR WITH MAGNETIC LOCK. PROVIDE CONDUIT/WIRING BACK TO POWER SUPPLIES AND ASSOCIATED PHYSICAL ACCESS CONTROL AND INTRUSION DETECTION PANELS. REFER TO
DETAIL 4 ON SHEET TY501.
2 SINGLE DOOR WITH MAGNETIC LOCK. PROVIDE CONDUIT/WIRING BACK TO POWER SUPPLIES AND ASSOCIATED PHYSICAL ACCESS CONTROL AND INTRUSION DETECTION PANELS. REFER TO
DETAIL 2 ON SHEET TY501.
3 DOUBLE BLAST RATED WINDOW WITH TWO (2) BALANCED MAGNETIC SWITCHES. PROVIDE CONDUIT/WIRING BACK TO THE INTRUSION DETECTION PANEL. REFER TO DETAIL 3 ON SHEET TY501.
4 SINGLE BLAST RATED WINDOW WITH BALANCED MAGNETIC SWITCH. PROVIDE CONDUIT/WIRING BACK TO INTRUSION DETECTION PANEL. REFER TO DETAIL 1 ON SHEET TY502.
5 OVERHEAD DOOR WITH MAGNETIC LOCK. PROVIDE CONDUIT/WIRING BACK TO POWER SUPPLIES AND ASSOCIATED PHYSICAL ACCESS CONTROL AND INTRUSION DETECTION PANELS. REFER TO
DETAIL 2 ON SHEET TY502.
6 EXTERIOR MOUNTED CAMERA WITH MOTION DETECTION. MOUNT AT 12'-6" AFG.
7 EXTERIOR MOUNTED CAMERA WITH MOTION DETECTION. MOUNT AT 9'-6" AFG.
8 INTRUSION DETECTION SYSTEM - KEY PAD. MOUNT AT 46" AFF TO CENTERLINE.
9 INTRUSION DETECTION SYSTEM - SPEAKER/SIREN. MOUNT AT 80" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER.
10 INTERCOM/VIDEO STATION. MOUNT AT 46" AFF TO CENTERLINE.
11 OVERHEAD DOOR CONTROLLER. COORDINATE LOCATION WITH OVERHEAD DOOR INSTALLER.
12 43" LED VIDEO SURVEILLANCE MONITOR. COORDINATE LOCATION AND MOUNTING HEIGHT WITH OWNER.
13 REMOTE VASS/SSTV WORKSTATION - PROVIDE WITH WALL MOUNT BRACKET AND LOCATE BEHIND 43" MONITOR. COORDINATE MOUNTING HEIGHT AND LOCATION WITH OWNER.
14 GATE WITH MAGNETIC LOCK. PROVIDE CONDUIT/WIRING BACK TO POWER SUPPLIES AND ASSOCIATED PHYSICAL ACCESS CONTROL PANEL. REFER TO DETAIL 6 ON SHEET TY501.
15 ALL PHYSICAL ACCESS CONTROL DEVICES SHALL BE WEATHERPROOF (IP66 RATED).
GENERAL NOTES:
1 ALL SECURITY ELECTRONICS CABLING SHALL BE INSTALLED IN CONDUIT.
2 REFER TO SHEETS TY601 THRU TY603 FOR PHYSICAL ACCESS CONTROL SYSTEM RISER DIAGRAMS.
3 REFER TO SHEETS TY501 THRU TY502 FOR PHYSICAL ACCESS CONTROL SYSTEM DETAILS.
4 COORDINATE WITH DOOR HARDWARE INSTALLER FOR ALL REQUIRED PACS CONNECTIONS AND ROUGH-IN REQUIREMENTS.
5 REFER TO SHEET TY604 FOR INTRUSION DETECTION AND INTERCOM SYSTEMS RISER DIAGRAMS.
6 REFER TO SHEETS TY605 AND TY606 FOR VIDEO SURVEILLANCE SYSTEM RISER DIAGRAM.
7 REFER TO SHEETS TY503 AND TY504 FOR CAMERA MOUNT DETAILS.
8 HEADEND EQUIPMENT ASSOCIATED WITH PHYSICAL ACCESS CONTROL, INTRUSION DETECTION, VIDEO SURVEILLANCE, AND INTERCOM SYSTEMS ARE LCOATED IN
SECURITY 206 (SHEET TY102).
360°
M
M
M
M
M
M
BOILER LEVEL
CONTROL ROOM
GENERATOR ROOM
204MAINTENACE ADDITION
S
S
F
F
S F
F
M S
X S
X
M
F
F
201D
203C
203B
203A X F
X
F F
S
X
MS
S
S
X M
S
S
W
201B 201C201A
S5
S14 S15
109C
6.7 76 8 9 10
54.94321
A
A.1
A.2
B
B.1
B.2 B.4
C
C.7
D
D.1
E
DD
CC
B.3
BB
X
F
S X
SX
FX
F
X
XF
10 10
111111
LPR
LPR
S S S
M M M M M M
SSSSSS
M
M
ANNEX
F
MF
BE7
CE1
CE2
F2031
H2041
G2071
K2051
SECURITY
IT
G2061
S
X
S
XS
M S
N1
31 31 31
J2011 J2012 J2013
323232
J2014
S
M X
S S
X
S
DA
DA
DA
DA
DA
DA
DA
DA
SS
S
M
DA DA DA
BE6
G2051
H2011 38
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
NORTH
KEYPLAN
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502)836-4232
/1
/2
:0
:0
P
M
TY102
SECURITY ELECTRONICS
BOILER LEVEL
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
1-07-2022 PJB PJB0506-0011
100% CORRECTED
CONSTRUCTION DOCUMENTS
NOT FOR CONSTRUCTION
FULLY SPRINKLERED
SCALE: 1/4" = 1'-0"
SECURITY ELECTRONICS - BOILER LEVEL
18 SURFACE MOUNTED 360-DEG FISHEYE PANORAMIC CAMERA. FIELD COORDINATE EXACT MOUNTING LOCATION FOR OPTIMAL COVERAGE.
19 INTRUSION DETECTION SYSTEM - KEY PAD. MOUNT AT 46" AFF TO CENTERLINE.
20 INTRUSION DETECTION SYSTEM - SPEAKER/SIREN. MOUNT AT 80" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER.
21 IP VIDEO MASTER STATION - DESK MOUNTED.
22 INTRUSION DETECTION SYSTEM CONTROL PANEL. REFER TO SPECIFICATION SECTION 281600.
23 CAT 6A CABLE, 1"C FROM INTRUSION DETECTION CONTROL PANEL TO DEDICATED PHYSICAL ACCESS CONTROL/INSTRUSION DETECTION SYSTEM PATCH PANEL IN THE SECURITY ELECTRONICS EQUIPMENT RACK.
24 WALL-MOUNTED EQUIPMENT RACK FOR THE INTERCOM SYSTEM HEADEND EQUIPMENT.
25 CAT 6A UTP, 1"C FROM INTERCOM SYSTEM EQUIPMENT TO A DEDICATED PHYSICAL ACCESS CONTROL/INTRUSION DETECTION SYSTEM PATCH PANEL IN THE SECURITY ELECTRONICS EQUIPMENT RACK.
26 TELECOMMUNICATIONS EQUIPMENT RACK. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
27 PROVIDE 1"C WITH 2-STRAND SINGLEMODE (OS2) OPTICAL FIBER CABLE FROM FIBER TERMINATION PANEL (SECURITY ELECTRONICS EQUIPMENT RACK) TO POE MANAGED SWITCH IN VIDEO SURVEILLANCE
EQUIPMENT RACK.
28 PROVIDE 2-STRAND MULTIMODE (OM4) OPTICAL FIBER FROM FIBER TERMINATION PANEL (TELECOMMUNICATIONS EQUIPMENT RACK) TO A DEDICATED PHYSICAL ACCESS CONTROL/INTRUSION DETECTION SYSTEM POE
MANAGED SWITCH (SECURITY ELECTRONICS EQUIPMENT RACK). ROUTE VIA 1" INNERDUCT IN WIRE-TROUGH REFERENCED ON SHEET E-402.
29 REMOTE VASS/SSTV WORKSTATION.
30 TELECOMMUNCIATIONS GROUNDING BUSBAR (TGB), REFER TO GROUDNING CONNECTIONS SHOWN ON DETAIL 7, SHEET E-503. IN ADDITION, PROVIDE #6 AWG BONDING JUMPER TO EACH METALLIC ENCLOSURE.
31 OVERHEAD DOOR CONTROLLER. COORDINATE LOCATION WITH OVERHEAD DOOR INSTALLER.
32 MOUNT CAMERA BELOW CATWALK. PROVIDE COVERAGE OF BOILER CONTROL PANEL.
33 INTERCOM/VIDEO STATION. MOUNT AT 46" AFF TO CENTERLINE.
34 PROVIDE CONNECTION FROM FIRE ALARM CONTROL MODULE TO PHYSICAL ACCESS CONTROL SYSTEM. CONTROLLED DOORS SHALL ALLOW FREE EXIT UPON ACTIVATION OF THE FIRE ALARM SYSTEM AS REQUIRED
BY NFPA 72. COORDINATE WITH FIRE ALARM SYSTEM CONTRACTOR.
35 PROVIDE CONNECTION (GENERATOR FAULT COMMON ALARM) FROM GENERATOR CONTROLLER TO INTRUSION DETECTION CONTROL PANEL.
36 PROVIDE CONNECTION (BOILER FAULT COMMON ALARM) FROM BOILER MASTER CONTROL PANEL TO INTRUSION DETECTION CONTROL PANEL.
37 PULL BOX - REFER TO ELECTRICAL DRAWINGS.
38 WALL MOUNTED CAMERA WITH MOTION DETECTION. MOUNT AT 12'-0" ABOVE LANDING. COORDINATE MOUNTING HEIGHT WITH OTHER TRADES.
SHEET KEYNOTES:
1 EXTEND 12-STRAND SINGLEMODE (OS2) OPTICAL FIBER CABLE (ASSOCIATED WITH THE VA'S VIDEO SURVEILLANCE CAMPUS WIDE NETWORK) FROM FIBER TERMINATION PANEL IN EXISTING BUILDING 14'S IT ROOM TO
SECURITY ELECTRONICS EQUIPMENT RACK. REFER TO CONDUIT ROUTING SHOWN ON ELECTRICAL DRAWINGS ES101, E-100, EP101, AND E-402.
2 VIDEO SURVEILLANCE EQUIPMENT RACK. REFER TO DETAILS ON SHEET TY503 AND VIDEO SURVEILLANCE RISER DIAGRAM ON SHEET TY605. REFER TO SPECIFICATION SECTION 282300 AND PROVIDENCE VAMC
CAMERA SYSTEM GENERAL SPECIFICATIONS 2021.
3 SECURITY ELECTRONICS EQUIPMENT RACK. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
4 PHYSICAL ACCESS CONTROL PANELS AND DOOR POWER SUPPLIES- QUANTITY AS REQUIRED. REFER TO PACS RISER DIAGRAMS ON SHEET TY601 THROUGH TY603. REFER TO SPECIFICATION SECTION 281300.
5 PROVIDE CAT 6A CABLE FROM EACH PHYSICAL ACCESS CONTROL PANEL TO DEDICATED PHYSICAL ACCESS CONTROL/INTRUSION DETECTION SYSTEM PATCH PANEL IN THE SECURITY ELECTRONICS EQUIPMENT RACK.
ROUTE IN A COMMON 1"C.
6 SINGLE DOOR WITH ELECTRIC STRIKE. PROVIDE CONDUIT/WIRING BACK TO POWER SUPPLIES AND ASSOCIATED PHYSICAL ACCESS CONTROL AND INTRUSION DETECTION PANELS. REFER TO DETAIL 1 ON SHEET
TY501.
7 SINGLE DOOR WITH MAGNETIC LOCK. PROVIDE CONDUIT/WIRING BACK TO POWER SUPPLIES AND ASSOCIATED PHYSICAL ACCESS CONTROL AND INTRUSION DETECTION PANELS. REFER TO DETAIL 2 ON SHEET
TY501.
8 DOUBLE DOOR WITH MAGNETIC LOCK. PROVIDE CONDUIT/WIRING BACK TO POWER SUPPLIES AND ASSOCIATED PHYSICAL ACCESS CONTROL AND INTRUSION DETECTION PANELS. REFER TO DETAIL 4 ON SHEET
TY501.
9 DOUBLE BLAST RATED WINDOW WITH TWO (2) BALANCED MAGNETIC SWITCHES. PROVIDE CONDUIT/WIRING BACK TO THE INTRUSION DETECTION PANEL. REFER TO DETAIL 3 ON SHEET TY501.
10 SINGLE WINDOW WITH BALANCED MAGNETIC SWITCH. PROVIDE CONDUIT/WIRING BACK TO INTRUSION DETECTION PANEL. REFER TO DETAIL 1 ON SHEET TY502.
11 OVERHEAD DOOR WITH MAGNETIC LOCK. PROVIDE CONDUIT/WIRING BACK TO POWER SUPPLIES AND ASSOCIATED PHYSICAL ACCESS CONTROL AND INTRUSION DETECTION PANELS. REFER TO DETAIL 2 ON SHEET
TY502.
12 43" LED VIDEO SURVEILLANCE MONITOR. COORDINATE LOCATION AND MOUNTING HEIGHT WITH OWNER.
13 CEILING MOUNTED CAMERA WITH 90DEG LENS.
14 WALL MOUNTED CAMERA WITH MOTION DETECTION. MOUNT AS HIGH AS POSSIBLE, COORDINATE MOUNTING HEIGHT WITH OTHER TRADES.
15 90-DEG PANORAMIC CAMERA WITH MOTION DETECTION. SURFACE MOUNT TO BOTTOM OF STRUCTURE, COORDINATE MOUNTING HEIGHT WITH OTHER TRADES.
16 EXTERIOR MOUNTED CAMERA WITH MOTION DETECTION. MOUNT AT 12'-6" AFF (BOILER LEVEL).
17 EXTERIOR/CORNER MOUNTED CAMERA WITH LICENSE PLATE READER. MOUNT AT 9'-0" AFF (ANNEX LEVEL).
GENERAL NOTES:
1 ALL SECURITY ELECTRONICS CABLING SHALL BE INSTALLED IN CONDUIT.
2 REFER TO SHEETS TY601 THRU TY603 FOR PHYSICAL ACCESS CONTROL SYSTEM RISER DIAGRAMS.
3 REFER TO SHEETS TY501 THRU TY502 FOR PHYSICAL ACCESS CONTROL SYSTEM DETAILS.
4 COORDINATE WITH DOOR HARDWARE INSTALLER FOR ALL REQUIRED PACS CONNECTIONS AND ROUGH-IN REQUIREMENTS.
5 REFER TO SHEET TY604 FOR INTRUSION DETECTION AND INTERCOM SYSTEMS RISER DIAGRAMS
6 REFER TO SHEETS TY605 AND TY606 FOR VIDEO SURVEILLANCE SYSTEM RISER DIAGRAM.
7 REFER TO SHEETS TY503 AND TY504 FOR CAMERA MOUNT DETAILS.
360°360°
CATWALK LEVEL
ANNEX
54.94321
A
A.1
A.2
B
B.1
B.2 B.4
C
C.7
D
D.1
E
K3021 K3022
S S
M S
DA
H3021
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
NORTH
KEYPLAN
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502)836-4232
/1
/2
:0
:0
P
M
TY103
SECURITY ELECTRONICS
CATWALK LEVEL
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
1-07-2022 PJB PJB0506-0011
100% CORRECTED
CONSTRUCTION DOCUMENTS
NOT FOR CONSTRUCTION
FULLY SPRINKLERED
SCALE: 1/4" = 1'-0"
SECURITY ELECTRONICS - CATWALK LEVEL
SHEET KEYNOTES:
1 PENDANT MOUNTED 360-DEG FISHEYE PANORAMIC CAMERA. FIELD COORDINATE EXACT MOUNTING LOCATION FOR OPTIMAL COVERAGE.
2 SINGLE DOOR WITH MAGNETIC LOCK (CARD READER ON BOTH SIDES). PROVIDE CONDUIT/WIRING BACK TO POWER SUPPLIES AND ASSOCIATED PHYSICAL ACCESS CONTROL AND INTRUSION
DETECTION PANELS. REFER TO DETAIL 5 ON SHEET TY501.
3 WALL MOUNTED CAMERA WITH MOTION DETECTION. MOUNT AT 10'-0" AFF. COORDINATE MOUNTING HEIGHT WITH OTHER TRADES.
GENERAL NOTES:
1 ALL SECURITY ELECTRONICS CABLING SHALL BE INSTALLED IN CONDUIT.
2 REFER TO SHEETS TY601 THRU TY603 FOR PHYSICAL ACCESS CONTROL SYSTEM RISER DIAGRAMS.
3 REFER TO SHEETS TY501 THRU TY502 FOR PHYSICAL ACCESS CONTROL SYSTEM DETAILS.
4 COORDINATE WITH DOOR HARDWARE INSTALLER FOR ALL REQUIRED PACS CONNECTIONS AND ROUGH-IN REQUIREMENTS.
5 REFER TO SHEET TY604 FOR INTRUSION DETECTION AND INTERCOM SYSTEMS RISER DIAGRAMS.
6 REFER TO SHEETS TY605 AND TY606 FOR VIDEO SURVEILLANCE SYSTEM RISER DIAGRAM.
7 REFER TO SHEETS TY503 AND TY504 FOR CAMERA MOUNT DETAILS.
8 HEADEND EQUIPMENT ASSOCIATED WITH PHYSICAL ACCESS CONTROL, INTRUSION DETECTION, VIDEO SURVEILLANCE, AND INTERCOM SYSTEMS ARE LCOATED IN
270°
0°
M
0°
M
270°
M
180°M
54.94321
A
A.1
A.2
B
B.1
B.2 B.4
C
C.7
D
D.1
E
1 1
2 3
DE1 DE2
DE4 DE3
EE1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
NORTH
KEYPLAN
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502)836-4232
/1
/2
:0
:0
P
M
TY104
SECURITY ELECTRONICS
ROOF LEVEL
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
1-07-2022 PJB PJB0506-0011
100% CORRECTED
CONSTRUCTION DOCUMENTS
NOT FOR CONSTRUCTION
FULLY SPRINKLERED
SCALE: 1/4" = 1'-0"
SECURITY ELECTRONICS - ROOF LEVEL
SHEET KEYNOTES:
1 PENDANT MOUNTED 270-DEG PANORAMIC CAMERA WITH PARAPET MOUNT.
2 ROOF HATCH WITH BALANCED MAGNETIC SWITCH. PROVIDE CONDUIT/WIRING BACK TO INTRUSION DETECTION PANEL.
3 PENDANT MOUNTED 180-DEG PANORAMIC CAMERA WITH PARAPET MOUNT (ANNEX ROOF).
GENERAL NOTES:
1 ALL SECURITY ELECTRONICS CABLING SHALL BE INSTALLED IN CONDUIT.
2 REFER TO SHEETS TY601 THRU TY603 FOR PHYSICAL ACCESS CONTROL SYSTEM RISER DIAGRAMS.
3 REFER TO SHEETS TY501 THRU TY502 FOR PHYSICAL ACCESS CONTROL SYSTEM DETAILS.
4 COORDINATE WITH DOOR HARDWARE INSTALLER FOR ALL REQUIRED PACS CONNECTIONS AND ROUGH-IN REQUIREMENTS.
5 REFER TO SHEET TY604 FOR INTRUSION DETECTION AND INTERCOM SYSTEMS RISER DIAGRAMS.
6 REFER TO SHEETS TY605 AND TY606 FOR VIDEO SURVEILLANCE SYSTEM RISER DIAGRAM.
7 REFER TO SHEETS TY503 AND TY504 FOR CAMERA MOUNT DETAILS.
8 HEADEND EQUIPMENT ASSOCIATED WITH PHYSICAL ACCESS CONTROL, INTRUSION DETECTION, VIDEO SURVEILLANCE, AND INTERCOM SYSTEMS ARE LCOATED IN
SUSPENDED CEILING
ELECTRIC
STRIKE
46"
DOORS: 203B, 203C
1#16 UTP, 3/4"C
BALANCED MAGNETIC SWITCH
JUNCTION
BOX
SECURE
CONTACTLESS SMARTCARD
READER WITH KEYPAD
(UNSECURE SIDE OF DOOR)
2#18 UTP, 3/4"C
POWER
SUPPLY
120VAC
24VDC
CLASS II STEPDOWN
TRANSFORMER
5C #22 AWG, 3/4"C
POWER
SUPPLY
120VAC
24VDC
CLASS II STEPDOWN
TRANSFORMER
REQUEST TO EXIT (REX)
DUAL TECH MOTION DETECTOR
2#18 UTP, 3/4"C
TWO-DOOR
INTERFACE
MODULE
RS485B CABLE BETWEEN
MODULES AND NETWORK
CONTROLLER
2#16 UTP, 4#18 UTP, 1"C
(WHERE PRESENT)
1#16 UTP, 3/4"C
EMERGENCY REX
PUSHBUTTON
GENERAL NOTE:
1. NOTE SHOWN - PROVIDE ADDITIONAL
CONDUIT/WIRING TO INTRUSION DETECTION
PANEL FROM BALANCED MAGNETIC
SWITCH (DPDT).
DOOR PROP ALARM (SET @ 10 SEC)
DOORS: 101A, 102A, 107, 109B, 109C
201D, 203A, 206, 207
BALANCED MAGNETIC SWITCH
JUNCTION
BOX
SECURE
1#16 UTP, 3/4"C
POWER
SUPPLY
120VAC
24VDC
CLASS II STEPDOWN
TRANSFORMER
POWER
SUPPLY
120VAC
24VDC
TWO-DOOR
INTERFACE
MODULE
RS485B CABLE BETWEEN
MODULES AND NETWORK
CONTROLLER
CLASS II STEPDOWN
TRANSFORMER
2#18 UTP, 3/4"C
MAGNETIC LOCK
SUSPENDED CEILING
(WHERE PRESENT)
46"
CONTACTLESS SMARTCARD
READER WITH KEYPAD
(UNSECURE SIDE OF DOOR)
EMERGENCY REX
PUSHBUTTON
5C #22 AWG, 3/4"C
1#16 UTP, 3/4"C
2#16 UTP, 4#18 UTP, 1"C
REQUEST TO EXIT (REX)
DUAL TECH MOTION DETECTOR
2#18 UTP, 3/4"C
GENERAL NOTE:
1. NOTE SHOWN - PROVIDE ADDITIONAL
CONDUIT/WIRING TO INTRUSION DETECTION
PANEL FROM BALANCED MAGNETIC
SWITCH (DPDT).
DOOR PROP ALARM (SET @ 10 SEC)
DOORS: 109A
MAGNETIC LOCK
46"
CONTACTLESS SMARTCARD
READER WITH KEYPAD
(UNSECURE SIDE OF DOOR)
EMERGENCY REX
PUSHBUTTON
BALANCED MAGNETIC
SWITCH
JUNCTION
BOX
REQUEST TO EXIT (REX)
DUAL TECH MOTION DETECTOR
POWER
SUPPLY
24VDC
TWO-DOOR
INTERFACE
MODULE
RS485B CABLE BETWEEN
MODULES AND NETWORK
CONTROLLER
CLASS II STEPDOWN
TRANSFORMER
120VAC
POWER
SUPPLY
120VAC
24VDC
CLASS II STEPDOWN
TRANSFORMER
SUSPENDED CEILING
(WHERE PRESENT)
3#16 UTP, 4#18 UTP, 1"C
5C #22 AWG, 3/4"C
1#16 UTP, 3/4"C
1#16 UTP, 3/4"C EACH
2#18 UTP, 3/4"C
2#18 UTP, 3/4"C
SECURE
GENERAL NOTE:
1. NOTE SHOWN - PROVIDE ADDITIONAL
CONDUIT/WIRING TO INTRUSION DETECTION
PANEL FROM BALANCED MAGNETIC
SWITCH (DPDT).
DOOR PROP ALARM
(SET @ 10 SEC)
JUNCTION
BOX
TO INTRUSION
DETECTON PANEL
SUSPENDED CEILING
(WHERE PRESENT)
BALANCED MAGNETIC
SWITCH
1#18 UTP, 3/4"C
WINDOWS: S1, S3, S4
N1, S8
1#18 UTP, 3/4"C
DOORS: 302
BALANCED MAGNETIC SWITCH
JUNCTION
BOX
SECURE
1#16 UTP, 3/4"C
POWER
SUPPLY
120VAC
24VDC
CLASS II STEPDOWN
TRANSFORMER
POWER
SUPPLY
120VAC
24VDC
TWO-DOOR
INTERFACE
MODULE
RS485B CABLE BETWEEN
MODULES AND NETWORK
CONTROLLER
CLASS II STEPDOWN
TRANSFORMER
2#18 UTP, 3/4"C
MAGNETIC LOCK
SUSPENDED CEILING
(WHERE PRESENT)
46"
TWO (2) CONTACTLESS
SMARTCARD READER WITH
KEYPAD (SECURE AND
UNSECURE SIDE OF DOOR)
TWO (2) 5C #22 AWG, 1"C
1#16 UTP, 2#18 UTP, 1"C
GENERAL NOTE:
1. NOTE SHOWN - PROVIDE ADDITIONAL
CONDUIT/WIRING TO INTRUSION DETECTION
PANEL FROM BALANCED MAGNETIC
SWITCH (DPDT).
DOOR PROP ALARM (SET @ 10 SEC)
GRADE
UNSECURE
CONTACTLESS SMARTCARD
READER WITH KEYPAD
(EXTERIOR OF BUILDING)
MAGNETIC LOCK W/ STATUS
RELAY CONTACT
REX PUSHBUTTON - LOCATED
INSIDE FENCE
POWER
SUPPLY
24VDC
TWO-DOOR
INTERFACE
MODULE
RS485B CABLE BETWEEN
MODULES AND NETWORK
CONTROLLER
CLASS II STEPDOWN
TRANSFORMER
120VAC
JUNCTION
BOX
POWER
SUPPLY
120VAC
24VDC
5C #22 AWG, 3/4"C1#16 UTP, 3/4"C
1#16 UTP, 1#18 UTP, 3/4"C
2#16 UTP, 1#18 UTP, 3/4"C
CONDUIT UNDERGROUND TO BUILDING
(ROUTE INSIDE FENCED AREA)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502)836-4232
/1
/2
:0
:0
P
M
TY501
SECURITY ELECTRONICS
PHYSICAL ACCESS CONTROL SYSTEM
DOOR CONTROL DETAILS I
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
1-07-2022 PJB PJB0506-0011
100% CORRECTED
CONSTRUCTION DOCUMENTS
NOT FOR CONSTRUCTION
FULLY SPRINKLERED
NOT TO SCALE
TYPICAL SINGLE DOOR WITH ELECTRIC STRIKE DETAIL
NOT TO SCALE
TYPICAL SINGLE DOOR WITH MAGNETIC LOCK DETAIL
NOT TO SCALE
TYPICAL DOUBLE DOOR WITH MAGNETIC LOCK DETAIL
NOT TO SCALE
TYPICAL DOUBLE WINDOW DETAIL
NOT TO SCALE
TYPICAL SINGLE DOOR WITH MAGNETIC
LOCK DETAIL (CARD READER BOTH SIDES)
NOT TO SCALE
TYPICAL PEDESTRIAN GATE WITH MAGNETIC LOCK DETAIL
JUNCTION
BOX
SUSPENDED CEILING
(WHERE PRESENT)
BALANCED MAGNETIC
SWITCH
1#18 UTP, 3/4"C
WINDOWS: S2, S13, E1
S14, S15
1#18 UTP, 3/4"C
TO INTRUSION
DETECTON PANEL
SUSPENDED CEILING
DOORS: 102B, 108
201A, 201B, 201C
SECURE
POWER
SUPPLY
120VAC
24VDC
CLASS II STEPDOWN
TRANSFORMER
TWO-DOOR
INTERFACE
MODULE
RS485B CABLE BETWEEN
MODULES AND NETWORK
CONTROLLER
(WHERE PRESENT)
FLOOR MOUNTED
MAGNETIC SWITCH
RECESSED
JUNCTION BOX
46"
CONTACTLESS SMARTCARD
READER WITH KEYPAD
(SECURE SIDE OF DOOR)
UP/DOWN/STOP
PUSHBUTTON
4#14, 1#14 GND, 3/4"C
1#16 UTP, 1#18 UTP, 3/4"C
COILING DOOR OPERATOR
JUNCTION
BOX
1#16 UTP, 3/4"C
5-COND, #22 AWG, 3/4"C
5-COND, #22 AWG, 3/4"C
3#16 UTP, 2#18 UTP, 1"C
GENERAL NOTE:
1. NOTE SHOWN - PROVIDE ADDITIONAL
CONDUIT/WIRING TO INTRUSION DETECTION
PANEL FROM BALANCED MAGNETIC
SWITCH (DPDT).
MAGNETIC LOCK (TYP. OF 2)
DOOR PROP ALARM
(SET @ 120 SEC)
1#16 UTP, 2#18 UTP, 1"C
MULTI-TECHNOLOGY
PROXIMITY READER
W/ KEYPAD
INTERCOM CALL
STATION
CARD READER/INTERCOM
PEDESTAL (14-GAUGE COLD-
ROLLED STEEL W/ BLACK
EPOXY COATING)
3"
3"
⌀24”
STANCHION EDGE.
DOME BASE 1/2" TO
EDGE
1-1/4" SCHEDULE 40
PVC CONDUIT
1/2" DOME TO STANCHION
BASE EDGE TO SHED
WATER
FINSIHED GRADE
1"
36"
6"
INTERCOM CALL
STATION
INTERCOM PEDESTAL
(14-GAUGE COLD-ROLLED
STEEL W/ BLACK EPOXY
COATING)
MULTI-TECHNOLOGY
PROXIMITY READER
W/ KEYPAD
CARD READER PEDESTAL
(14-GAUGE COLD-ROLLED
STEEL W/ BLACK EPOXY
COATING)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502)836-4232
/1
/2
:0
:0
P
M
TY502
SECURITY ELECTRONICS
PHYSICAL ACCESS CONTROL SYSTEM
DOOR CONTROL DETAILS II
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
1-07-2022 PJB PJB0506-0011
100% CORRECTED
CONSTRUCTION DOCUMENTS
NOT FOR CONSTRUCTION
FULLY SPRINKLERED
NOT TO SCALE
TYPICAL SINGLE WINDOW DETAIL
NOT TO SCALE
TYPICAL OVERHEAD DOOR WITH MAGNETIC LOCK DETAIL
NOT TO SCALE
PEDESTAL BASE
NOT TO SCALE
PEDESTAL - ISOMETRIC
NOT TO SCALE
PEDESTAL ASSEMBLY - VISITOR ENTRANCE
NOT TO SCALE
PEDESTAL ASSEMBLY - EMPLOYEE ENTRANCE NOT TO SCALE
PEDESTAL ASSEMBLY - TEMPORARY GATE
1.5 INCH ALUMINUM ARM
FOR PARAPET MOUNT
WEATHERPROOF
JUNCTION BOX
ALUMINUM PARAPET
WALL MOUNT
270-DEGREE PANORAMIC
PENDANT MOUNT
EXTERIOR CAMERA
WEATHERPROOF
JUNCTION BOX
JUNCTION BOX MOUNTED IN
A SERVICEABLE LOCATION
ROOFTOP MOUNTED CURB FOR
JUNCTION BOX. COORDINATE WITH
ROOFING CONTRACTOR
JUNCTION BOX MOUNTED IN
A SERVICEABLE LOCATION
CORNER MOUNT
ADAPTER
ALUMINUM WALL
MOUNT ARM
PENDANT MOUNT
EXTERIOR CAMERA
FLEXIBLE
WATERTIGHT
RACEWAY
WEATHERPROOF
JUNCTION BOX
CAMERA BACK BOX
(COORDINATE WITH
CAMERA MANUFACTURER)
CEILING TILE
INDOOR DOME CAMERA
CABLE CONNECTOR
ADJUSTABLE BAR CEILING
HANGER OR EQUIVALENT
CABLE SUPPORT
CAT 6A UTP CABLE
PLENUM RATED
JUNCTION BOX MOUNTED IN
A SERVICEABLE LOCATION
ALUMINUM WALL
MOUNT ARM
PENDANT MOUNT CAMERA
(OUTDOOR/INDOOR)
WEATHERPROOF
JUNCTION BOX CONDUIT PENETRATION
HOLLOW CAMERA ARM
STEM LENGTH AS
REQUIRED BY
MOUNTING HEIGHT
FISHEYE PENDANT
MOUNTED CAMERA
CAMERA PENDANT MOUNT
CAMERA STEM
1" CONDUIT W/
VASS/SSTV CABLING
1" CONDUIT W/
VASS/SSTV CABLING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502)836-4232
/1
/2
:0
:0
P
M
TY503
SECURITY ELECTRONICS
VIDEO SURVEILLANCE
CAMERA MOUNTING DETAILS I
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
1-07-2022 PJB PJB0506-0011
100% CORRECTED
CONSTRUCTION DOCUMENTS
NOT FOR CONSTRUCTION
FULLY SPRINKLERED
NOT TO SCALE
PARAPET MOUNTED CAMERA WITH ROOF PENTRATION
NOT TO SCALE
CORNER MOUNTED CAMERA
NOT TO SCALE
SUSPENDED CEILING FIXED MINI-DOME
NOT TO SCALE
WALL MOUNTED CAMERA (OUTDOOR/INDOOR)
NOT TO SCALE
PENDANT MOUNTED CAMERA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .