S02 BD03252022 Drawings - 6_Plumbing.pdf

PDF 9 MB Posted

Attached to
Y1NB--650-19-100 Replace Boilers in Bldg 10 Federal contract opportunity
Solicitation number
36C24122R0084
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1

About this file

This package includes construction drawings and specifications for replacing boilers in a Veterans Affairs building. The project involves demolishing existing boilers and related piping on multiple levels of the building, and installing new boilers, associated piping, and related HVAC equipment. Site utilities will also be modified, including a new water storage tank. Bidders are advised to carefully review all 100 corrected construction documents detailing demolition requirements, new piping plans for various levels, and plumbing details. The work is to be performed at the Veterans Affairs Medical Center located at 830 Chalkstone Avenue in Providence, Rhode Island. The solicitation number for this opportunity is 36C24122R0084.

View the file

Other files for this federal contract opportunity

Other files attached to Y1NB--650-19-100 Replace Boilers in Bldg 10, newest first.
File Type Posted
36C24122R0084 0007.docx DOCX document
S06 AMENDED Drawing P-601.pdf PDF
36C24122R0084 0006.docx DOCX document
S06 AMENDED Spec Section 33 16 15 07202022.pdf PDF
S06 RFI Responses 07202022.pdf PDF
S06 RFI Responses 07192022.pdf PDF
S06 IMG_4044.pdf PDF
36C24122R0084 0004.docx DOCX document
S06 AMENDED Spec Section 03 52 00.pdf PDF
S06 ARCHITECTURAL DRAWINGS BULLETIN 2.pdf PDF
S06 IMG_4010.pdf PDF
S06 IMG_0098.pdf PDF
S06 RFI Responses.pdf PDF
S06 STRUCTURAL DRAWINGS BULLETIN 1.pdf PDF
S06 ELECTRICAL DRAWINGS BULLETIN 1.pdf PDF
S06 MECHANICAL DRAWINGS BULLETIN 1.pdf PDF
S06 EXHIBIT D Calculation of Self Performed Work Amended.pdf PDF
S06 JA CCTV System Boilers 650-19-100.pdf PDF
36C24122R0084 0003.docx DOCX document
S06 EXHIBIT C Past Performance Questionnaire.pdf PDF
36C24122R0084 0002.docx DOCX document
Site Visit Sign-In Sheet.pdf PDF
36C24122R0084 0001.docx DOCX document
S02 BD03252022 Drawings - 7b_Mechanical - Part 2.pdf PDF
S02 BD03252022 Drawings - 8a_Electrical - Part 1.pdf PDF
S02 BD03252022 - 100pc Const Docs - Specs Vol I.pdf PDF
S02 BD03252022 Drawings - 1_Hazardous Materials.pdf PDF
S02 BD03252022 Drawings - 2b_Civil - Part 2.pdf PDF
S02 BD03252022 Drawings - 3_Structural.pdf PDF
S02 BD03252022 Drawings - 4_Architecture.pdf PDF
S02 BD03252022 Drawings - 8b_Electrical - Part 2.pdf PDF
S02 BD03252022 Drawings - 9_Security Electronics.pdf PDF
S02 BD03252022 - 100pc Const Docs - Specs Vol II.pdf PDF
S02 BD03252022 - 100pc Const Docs - Specs Vol III.pdf PDF
S02 BD03252022 Drawings - 2a_Civil - Part 1.pdf PDF
S02 BD03252022 Drawings - 5_Fire Protection.pdf PDF
S02 BD03252022 Drawings - 7a_Mechanical - Part 1.pdf PDF
S02 BD03252022 -Slope Stability Report.pdf PDF
S02 BD03252022 - Soil Erosion and Sediment Control Plan.pdf PDF
S02 JA Lockset Boilers 650-19-100.pdf PDF
S02 JA Utility Plant Boilers 650-19-100.pdf PDF
S02 RI20220001 Wage Determinations.pdf PDF
S02 36C24122R0084 Solicitation.pdf PDF
S02 JA Fire Alarm System Boilers 650-19-100.pdf PDF
S02 VHA Supplemental Contract Requirements for Combatting COVID-19.pdf PDF
S02 EXHIBIT E VAAR Clause 852.219-77 Certificate of Compliance.pdf PDF
S02 EXHIBIT B Subcontractor Information and Consent Form.pdf PDF
S02 EXHIBIT D Calculation of Self Performed Work.pdf PDF
S02 EXHIBIT C Past Performance Questionnaire.pdf PDF
S02 EXHIBIT A Project Information Sheet for Contractors.pdf PDF
Show all 50

Y1NB--650-19-100 Replace Boilers in Bldg 10 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PLUMBING

ABBREVIATIONS, GENERAL NOTES

& SYMBOLS

P-001

AHTMJJM

NO. DESCRIPTION DATE

B

A

C

D

E

F

1 2 3 4 5 6 87 9

97 8654321

MILLER-REMICK LLC

PROFESSIONAL ENGINEER

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE

WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE

PROFESSIONAL ENGINEER.

Miller-Remick LLC

1010 KINGS HIGHWAY SOUTH

CHERRY HILL, NEW JERSEY 08034

PHONE: (856)429-4000

FAX: (856)429-5002

M.E.P. & Structural Engineering

A Service Disabled Veteran Owned Small Business

B

A

C

D

E

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ENGINEER OF RECORDCONSULTANT

Project Director

MR PROJECT NO: 0506-0011

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

100% CORRECTED

CONSTRUCTION DOCUMENTS

01-07-2022

4321 5

A

D

6.7 8 9 10

B

C

B.3

BB

DD

(D)4"SAN

(E)2"SAN

(D )4

(D)3"

(D)4"

(D)8"

(D)4"SAN

(D)4"FD

(D)4"FD

(D)4"FD

(D)4"FD

(D)4"FD

(E)2"FD

(E)4"FD

(D)4"FD

(D)4"FD

(E)4"FD

(E)4"FD

(E)FD

(D)4"SAN

(D )4 S A N

(D )4 S A N

(D )4 S A N

(D)4"SAN

(D )6

(D)8" (E)8"SAN

(E )4 S A N

(E )4 S A N

(E)4"SAN (E)4"SAN

(E )4 S A N

(E )4 S A N

(E )4

(D )4 S A N

(D)4"SAN(D)4"SAN

(D )2

(D)4"SAN(D)4"SAN

(D)4"SAN

(D)4"SAN

(D)4"SAN

(D)4"FD

(D )4 S A N

(D)4"SAN

(D)4"

(D)4"SAN

(D)4"FD

LOCKERS

RESTROOM

MAINTENANCE

DISCONNECT & CAP

(E)4"DCW

DISCONNECT AND REMOVE

(E)4"SD UP. INSTALL

TEMPORARY PIPING FOR

STORM WATER DURING

CONSTRUCTION.

DISCONNECT AND REMOVE

(E)4"SD UP. INSTALL

TEMPORARY PIPING FOR

STORM WATER DURING

CONSTRUCTION.

(D)4"FD

(D)8"

(D)8"SAN

(D)8"

(D)4"

(D)4"

INV.ELEV. 69.60'

(E)2"SAN UP

IN CHASE

(E)4"SAN UP

IN CHASE

(D)4"V

DISCONNECT AND

REMOVE (E)4"V UP.

(D)FCO

(D)FCO

(D)FCO

(D)FCO

(D)FCO

(E)FCO

(E)FCO

DISCONNECT

(E)4"SAN

DISCONNECT &

REMOVE FD

(E)3"SD UP

(E)3"SAN UP

(D)3"SAN UP

(D)FCO

(D)4"FD

(D)2"DCW

UP

DISCONNECT & CAP

(E)2"DCW

(E)4"

(E)2"DCW

(D)2"

DISCONNECT (E)8"SAN FROM SITE.

PREPARE FOR NEW CONNECTION.

PROTECT (E)SITE MAIN DURING

CONSTRUCTION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t o n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t th re e in c h o n e fo o t

PLAN

NORTH ACTUAL

NORTH

KEYPLAN

HAZARDOUS MATERIALS

MABBETT & ASSOCIATES, INC.

105 CENTRAL STREET, STONEHAM, MA 02180

PHONE: (781)275-6050

CIVIL / STRUCTURAL

LABELLA

303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614

PHONE: (585)454-6110

ARCHITECTURAL

OCULUS INC.

1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102

PHONE: (314)367-6100

ELECTRONIC SECURITY

GRW

801 CORPORATE DRIVE, LEXINGTON, KY 40503

PHONE: (859)223-3999

FIRE SUPPRESSION

KOFFEL ASSOCIATES

8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045

PHONE: (410)750-2246

PHYSICAL SECURITY

FORCE PROTECT SECURITY CONSULTANTS

10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407

PHONE: (502)836-4232

/1

/2

:3

:0

A

M

PD100

PLUMBING

DEMOLITION PIPING PLAN

UNDERSLAB

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

01-07-2022 PD AHTM0506-0011

100% CORRECTED

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"1

DEMOLITION PIPING PLAN - UNDERSLAB

GENERAL SHEET NOTES:

1. REFER TO DRAWING P-001 FOR PLUMBING SYMBOLS, ABBREVIATIONS, AND GENERAL

NOTES.

Revisions: Date:

D

6.7 8 9 10

B

C

B.3

BB

DD

(D)1 1/4"DCW (D)1 1/4"

(D )1

(D)1 1/2"

DISCONNECT &

REMOVE (E)4"V UP

(E)4"V RISE &

(E)4"SAN

DROP

DISCONNECT &

REMOVE WATER

SOFTENER & BRINE

TANK AND ALL

APPURTENANCES.

DISCONNECT & REMOVE

CITY WATER BACK TO

5'-0" OUTSIDE & CAP.

DISCONNECT

& REMOVE

VENT PIPING

BACK TO

MAIN & CAP.

DISCONNECT &

REMOVE FIXTURE.

CAP SANITARY PIPING

BELOW FLOOR.

DISCONNECT &

REMOVE HOSE BIBB.

RESTROOM

LOCKERS

MAINTENANCE

(E)2"V UP

(E)4"SAN

UP&DN

(E)4"V

RISE& DN

(E)4"V UP

(E)4"SD UP

(D)2"DCW

(D)2"DCW

UP

DISCONNECT &

REMOVE AIR

COMPRESSORS &

EQUIPMENT PAD.

(E)AIR

COMPRESSOR.

ACB-10-002

(D)AIR

COMPRESSOR

(D)AIR

COMPRESSOR

(D)4"SD

UP &DN(D)4"SD

UP &DN

(E)2"SAN DN

(E)1 1/2" RISE

IN CHASE

DISCONNECT &

RELOCATED (E)AIR

COMPRESSOR

RECIEVER

(E)FCO

(E)FCO

(D)FCO(D)FCO

(D)FCO

(D)FCO

(D)FCO

DISCONNECT &

REMOVE (E)4"V

UP&DN

(E)FD

(E)4"FD(E)4"FD

(E)4"FD

(D)4"FD

(D)4"FD

(D)1-1/4"DCW

DN

(D)2"DCW

RISE&DN

(D)2"SCW

UP

(D)2"SCW

DISCONNECT &

REMOVE HOSE BIBB.

(E)2"DCW &

(E)1 1/2" DHW

LOCATED ABOUT

CEILING.

DISCONNECT (E)2"DCW &

(E)1 1/2" DHW

PREPARE FOR NEW

CONNECTIONS

(E)2"V DN

DISCONNECT &REMOVE

ALL COMPRESSED AIR

PIPING BACK TO

EQUIPMENT.

DISCONNECT &REMOVE

ALL COMPRESSED AIR

PIPING BACK TO

EQUIPMENT.

DISCONNECT &

REMOVE HUB

DRAIN. REMOVE

PIPE BACK TO

RISER & CAP WITH

CO.

DISCONNECT &

REMOVE (E)4"V

PREPARE FOR NEW

CONNECTION

DISCONNECT AND REMOVE (E)24,000 GAL

WATER STORAGE TANK AND ALL

APPURTENANCES.

DISCONNECT ALL PIPING FROM TANK TO

BELOW GRADE. REFER TO CIVIL SITE PLANS

FOR CONTINUATION.

DISCONNECT AND

REMOVE (E)1"NG PIPING

FROM (E)UH, BACK TO

SITE. SITE TO CAP NG

AT MAIN.

DISCONNECT & REMOVE DUAL PUMP SKID.

DISCONNECT & REMOVE ALL VALVES,

PIPING AND APPURTENANCES FROM

PUMPS. REMOVE PIPE BACK TO SITE.

SITE TO CAP WATER AT MAIN.

DISCONNECT &

REMOVE OVERFLOW

3"

1"

4"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t

NORTH

KEYPLAN

HAZARDOUS MATERIALS

MABBETT & ASSOCIATES, INC.

105 CENTRAL STREET, STONEHAM, MA 02180

PHONE: (781)275-6050

CIVIL / STRUCTURAL

LABELLA

303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614

PHONE: (585)454-6110

ARCHITECTURAL

OCULUS INC.

1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102

PHONE: (314)367-6100

ELECTRONIC SECURITY

GRW

801 CORPORATE DRIVE, LEXINGTON, KY 40503

PHONE: (859)223-3999

FIRE SUPPRESSION

KOFFEL ASSOCIATES

8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045

PHONE: (410)750-2246

PHYSICAL SECURITY

FORCE PROTECT SECURITY CONSULTANTS

10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407

PHONE: (502)836-4232

/1

/2

:3

:0

A

M

PD101

PLUMBING

DEMOLITION PIPING PLAN

MAIN LEVEL

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

01-07-2022 PD AHTM0506-0011

100% CORRECTED

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"1

DEMOLITION PIPING PLAN - MAIN LEVEL

GENERAL SHEET NOTES:

1. REFER TO DRAWING P-001 FOR PLUMBING SYMBOLS, ABBREVIATIONS, AND GENERAL

NOTES.

Revisions: Date:

SCALE: 1/4" = 1'-0"2

DEMOLITION WATER STORAGE TANK

D

6.7 8 9 10

B

C

B.3

BB

DD

(D)2"SW

(D)2"DCW

(D)BOILER (D)BOILER (D)BOILER

(D)1 1/4"DCW (D)1 1/4"DCW

(E)3"V

DISCONNECT &

REMOVE (E)4" V

UP&DN

(D)4"SD UP

&DN

(D)4"SD UP

&DN

DISCONNECT &

REMOVE (E)4"V

UP&DN

(D)1 1/4"DCW

DN

(D)1 1/4"DCW

UP

(D)2"DCW UP

(D)2"DCW DN

(D)2"SW UP

(D)2"SW DN

(D)2"DCW DN

(D)2"SW DN

(E)4"V

UP&DN

(E)3"SD

DROP

(E)3"SD

UP TO

(E)RD

(E)4"SD

UP&DN (E)3"SD

DROP

(D) WATER HEATER

MP302

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t

NORTH

KEYPLAN

HAZARDOUS MATERIALS

MABBETT & ASSOCIATES, INC.

105 CENTRAL STREET, STONEHAM, MA 02180

PHONE: (781)275-6050

CIVIL / STRUCTURAL

LABELLA

303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614

PHONE: (585)454-6110

ARCHITECTURAL

OCULUS INC.

1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102

PHONE: (314)367-6100

ELECTRONIC SECURITY

GRW

801 CORPORATE DRIVE, LEXINGTON, KY 40503

PHONE: (859)223-3999

FIRE SUPPRESSION

KOFFEL ASSOCIATES

8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045

PHONE: (410)750-2246

PHYSICAL SECURITY

FORCE PROTECT SECURITY CONSULTANTS

10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407

PHONE: (502)836-4232

/1

/2

:3

:0

A

M

PD102

PLUMBING

DEMOLITION PIPING PLAN

BOILER LEVEL

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

01-07-2022 PD AHTM0506-0011

100% CORRECTED

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"1 DEMOLITION PIPING PLAN BOILER LEVEL

GENERAL SHEET NOTES:

1. REFER TO DRAWING P-001 FOR PLUMBING SYMBOLS, ABBREVIATIONS, AND GENERAL

M

A

D

6.7 8 9 10

B

C

B.3

BB

DD

E

(E)2"SAN

(E)2"FD

(E)8"SAN

(E )4 S A N

(E )4 S A N

(E)4"SAN (E)4"SAN

(E )4 S A N

(E)4"SAN

4"SAN

4"SAN

4"SAN

S A N

S A N

S A N

(E)4"SAN

/8

(E)8"SAN

S A N

4"SAN

UP TO

4"GCO

4"SAN UP

TO 4"FCO

4"FCO

4"FCO

4"SAN UP

TO 4"FCO

4"SAN

UP TO

4"GCO

MAINTENANCE

OFFICE

LOCKERS

RESTROOM

BREAK ROOM

6"F

REFER TO SITE CIVIL PLANS

FOR CONTINUATION

REFER TO SITE CIVIL PLANS

FOR CONTINUATION

4" CITY WATER

FROM STORAGE TANK

INV. ELEV. 63.83'

(TOP OF PIPE 1'-0"

BELOW FROST)

INV. ELEV. 64.46'

4" CITY WATER

INV. ELEV. 65.0'

(TOP OF PIPE 1'-0"

BELOW FROST)

4"SAN UP

TO 4"GCO

INV. ELEV. 65.54' REFER TO SITE CIVIL PLANS

FOR CONTINUATION

INV. ELEV. 68.92'

INV. ELEV. 66.08'

4"ICW

S D

S A N

S D

6"SD

4"SAN

4"SAN UP

TO 4"FCO

4"FD-D

4"V UP

ON WALL

INV.ELEV. 69.00'

INV.ELEV. 68.00'

(E)SAN RISERS

IN CHASE

(E)4"SAN UP

IN CHASE

6"FIRE WATER UP

REFER TO FIRE PROTECTION

DRAWING FOR CONTINUATION

4"TOWER WATER UP

4"SAN UP

INV.ELEV. 70.58'

2"SAN UP

IN WALL

INV.ELEV. 69.60

4"DCW UP

ON WALL

(E)3"SD UP

(E)3"SAN UP

TO CO

2"SAN UP

S A N

CONNECT

3"SAN TO

(E)4"SAN

CONNECT

4"SAN TO

(E)4"SAN

1/8" / 1'-0"

/8

/8

ANNEX

TRANSFORMER

MAINTENANCE -

ADDITION

4"SAN UP

4"SAN UP

4"SAN UP

4"V UP

4"SAN

4"V4"SAN

4"SAN

4"SAN

4"SAN

4"SAN

4"SAN

4"SAN

4"SAN

4"SAN

4"SAN

(E)4"SAN UP

TO (E)4"FCO

6"SD UP

4"SAN

UP TO

4"FCO

4"SAN

UP TO

4"FCO

CONNECT

4"SAN TO

(E)4"SAN

4"SAN 6"SAN

4"SAN

4"FD-D

4"SAN

1/8" / 1'-0" 1/8" / 1'-0"

CONNECT 4"SAN

TO (E)4"SAN &

EXTEND

4"SAN

4"SAN

4"SAN

4"SAN

1/8" / 1'-0"

1/8" / 1'-0"

INV.ELEV. 70.63'

FIN FLR

INV.ELEV.

72.00'

FIN FLR

INV.ELEV.

72.00'

INV. ELEV. 69.67'

INV. ELEV. 65.67'

INV. ELEV. 68.67'

INV. ELEV. 66.46'

FIN FLR

INV.ELEV.

68.50'

INV. ELEV. 69.08'

INV. ELEV. 69.21'

4"FD-D

/8

1/8" / 1'-0"

1/8" / 1'-0"

/8

4"SAN

(E)4"SAN

4"SAN

4"SAN UP

TO FD

4"SAN UP

TO FD

(E)4"SAN

UP TO

(E)FD

(E)4"SAN

UP TO

(E)FD

(E)4"SAN

UP TO

(E)FD

(E)4"SAN UP

TO (E)4"FCO

(E)4"SAN

UP TO

(E)FD

4"SAN UP

TO FD

4"SAN UP

TO FD

4"SAN UP

TO FD

4"SAN UP

TO FD

4"SAN UP

TO FD

4"SAN UP

4"SAN UP

TO FD

4"SAN UP

TO FD

4"SAN UP

TO FD

4"SAN UP

TO FD

4"SAN UP

TO FD

4"SAN UP

TO FD

4"SAN UP

TO FD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t

NORTH

KEYPLAN

HAZARDOUS MATERIALS

MABBETT & ASSOCIATES, INC.

105 CENTRAL STREET, STONEHAM, MA 02180

PHONE: (781)275-6050

CIVIL / STRUCTURAL

LABELLA

303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614

PHONE: (585)454-6110

ARCHITECTURAL

OCULUS INC.

1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102

PHONE: (314)367-6100

ELECTRONIC SECURITY

GRW

801 CORPORATE DRIVE, LEXINGTON, KY 40503

PHONE: (859)223-3999

FIRE SUPPRESSION

KOFFEL ASSOCIATES

8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045

PHONE: (410)750-2246

PHYSICAL SECURITY

FORCE PROTECT SECURITY CONSULTANTS

10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407

PHONE: (502)836-4232

/1

/2

:3

:1

A

M

PP100

PLUMBING

PIPING PLAN

UNDERSLAB

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

01-07-2022 PD AHTM0506-0011

100% CORRECTED

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"1 PIPING PLAN - UNDERSLAB

GENERAL SHEET NOTES:

1. REFER TO DRAWING P-001 FOR PLUMBING SYMBOLS, ABBREVIATIONS, AND GENERAL

360°

270°

M

0°

M

0°

M

270°

M

180° M

360°

M

M

M

M

M

M

360°

0°

M

M

M

M M

M

M

4321 5

A

D

6.7 8 9 10

C B.3

CC

BB

DD

E

(E)8"SAN

(E )4 S A N

(E)8"SAN

4"GCO

4"GCO

4"SAN

6"F

REFER TO SITE CIVIL PLANS

FOR CONTINUATION

REFER TO SITE CIVIL PLANS

FOR CONTINUATION

4"CITY WATER

FROM STORAGE

TANK

4" CITY WATER

50,000

GAL

WATER

STORAGE

TANK

4"GCO

6"SD

4"WATER TO BUILDING

4"WATER UP TO TANK

HEAT TAPED

FUEL

OIL

TANK

30000

GAL

FUEL

OIL

TANK

30000

GAL

REFER TO SITE CIVIL PLANS

FOR CONTINUATION

INV. ELEV. 68.92'

INV. ELEV. 66.08'

4"WATER UP

TO HOT BOX

4"WATER DN

IN HOT BOX

4"

REFER TO SITE CIVIL PLANS

FOR CONTINUATION 4"WATER UP TO TANK

HEAT TAPED

4"ICW

6"OVERFLOW UP

&DROP TO 18"ABOVE

GRADE

8"VENT

3' - 11"

WST-10-S-001

HBX-10-S-001

4"RPZ-10-S-001

PS100

INV. ELEV. 63.83'

(TOP OF PIPE 1'-0"

BELOW FROST)

INV. ELEV. 64.46'

INV. ELEV. 65.0'

(TOP OF PIPE 1'-0"

BELOW FROST)

INV. ELEV. 65.54'

6"SAN

FILL CONTROL VALVE

HEAT TRACE CONTROLLER

HOT BOX HEATER

FIN FLR

INV.ELEV.

72.00'

FIN FLR

INV.ELEV.

72.00'

FIN FLR

INV.ELEV.

68.50'

HOT

BOX

4"RPZ-10-S-001

4" 4"

CV-10-S-001

BYPASS

FOR CONTINUATION REFER

TO SITE CIVIL DRAWINGS

GRADE

CURB

DRAIN

HOLE

HEATER

TO WATER STORAGE TANK

7' - 9"

/2

MOTORIZED CONTROL VALVE

FOR REMOTE MONITORING

HEAT TRACE

CONTROLLER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t

NORTH

KEYPLAN

HAZARDOUS MATERIALS

MABBETT & ASSOCIATES, INC.

105 CENTRAL STREET, STONEHAM, MA 02180

PHONE: (781)275-6050

CIVIL / STRUCTURAL

LABELLA

303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614

PHONE: (585)454-6110

ARCHITECTURAL

OCULUS INC.

1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102

PHONE: (314)367-6100

ELECTRONIC SECURITY

GRW

801 CORPORATE DRIVE, LEXINGTON, KY 40503

PHONE: (859)223-3999

FIRE SUPPRESSION

KOFFEL ASSOCIATES

8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045

PHONE: (410)750-2246

PHYSICAL SECURITY

FORCE PROTECT SECURITY CONSULTANTS

10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407

PHONE: (502)836-4232

/1

/2

:3

:4

A

M

PS100

SITE

UTILITIES POINT OF ENTRANCES

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

01-07-2022 AP AHTM0506-0011

100% CORRECTED

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/8" = 1'-0"1

SITE -UTILITIES POINT OF ENTRANCES

GENERAL SHEET NOTES:

1. REFER TO DRAWING P-001 FOR PLUMBING SYMBOLS, ABBREVIATIONS, AND GENERAL

NOTES.

Revisions: Date:

SCALE: 1/4" = 1'-0"2

HOT BOX SECTION

D

6.7 8 9 10

B

C

B.3

BB

DD

(D)4"SD DN

(D)4"SD DN

DISCONNECT &

REMOVE (E)4"V DN

(D)2"SCW DN

(D)2"DCW DN

(E)4"V

UP&DN

(E)3"SD

UP TO

(E)RD

(E)4"SD

DN

(D)4"SD UP

(D)4"SD UP

(E)4"SD

RISE

(E)4"SD

UP TO

(E)RD

DISCONNECT &

REMOVE (E)4"V UP

& (E)4"VTR

PATCH ROOF

PENETRATION

DISCONNECT &

REMOVE (E)4"V

UP&DN & (E)4"VTR

PATCH ROOF

PENETRATION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t

NORTH

KEYPLAN

HAZARDOUS MATERIALS

MABBETT & ASSOCIATES, INC.

105 CENTRAL STREET, STONEHAM, MA 02180

PHONE: (781)275-6050

CIVIL / STRUCTURAL

LABELLA

303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614

PHONE: (585)454-6110

ARCHITECTURAL

OCULUS INC.

1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102

PHONE: (314)367-6100

ELECTRONIC SECURITY

GRW

801 CORPORATE DRIVE, LEXINGTON, KY 40503

PHONE: (859)223-3999

FIRE SUPPRESSION

KOFFEL ASSOCIATES

8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045

PHONE: (410)750-2246

PHYSICAL SECURITY

FORCE PROTECT SECURITY CONSULTANTS

10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407

PHONE: (502)836-4232

/1

/2

:3

:0

A

M

PD103

PLUMBING

DEMOLITION PIPING PLAN

CATWALK LEVEL

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

01-07-2022 Checker Author0506-0011

100% CORRECTED

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"1 DEMOLITION PLAN - CATWALK LEVEL

C

4321 5

A

D

6.7 8 9 10

B

C

B.3

BB

DD

E

(E)1 1/2"V

4"FD-S

4"FD-S

MAINTENANCE

OFFICE

LOCKERS

RESTROOM

BREAK ROOM

(E)4" VENT UP

D C W

D H W

3"DCW

3"DCW 1 1/2"DCW 1 1/2"DCW

4"FD-S

4"FD-E

4"FD-S

FLASH

TANK

4"FD-E

4"FD-E

P-528

2"V

TO (E)2"V

4"V UP

4"V

DN

3"DCW

RISE

PWP-10-01-001

ACB-10-002

AIR

COMPRESSOR

(E)AIR

COMPRESSOR

1 1/2"DCW

1 1/2"DHW

3"DCW

P-801

P-801 P-801

P-803

4"FCO

4"FCO

4"FCO

4"FCO

4"GCO

4"GCO

TRANSFORMER

ANNEX

MAINTENANCE -

ADDITION

SHOWER

P-707

WATER

SOFTENER

WS-10-01-001

ACB-10-01-001

PROCESS

WATER

PUMPS

4"GCO

4"SAN UP

TO FD

4"SAN DN

2"V UP

4"SAN UP

TO FD

4"SAN DN

2"V UP

4"SAN UP

TO FD

4"SAN DN

2"V UP

PP401

6"SD UP

4"SAN UP

TO FD

4"SAN DN

2"V RISE

4"V UP

4"V RISE&DN

4"FCO

4"FD-D LOCATED IN

BOTTOM OF FUEL

OIL TRENCH

4"FD-D LOCATED IN

BOTTOM OF FUEL

OIL TRENCH

4"FD-D LOCATED IN

BOTTOM OF FUEL

OIL TRENCH

4"SAN UP

TO FD

4"SAN DN

2"V RISE

4"DCW

SERVICE RISE

W/SOV & DN

RPZ-10-01-001

4"SAN

FOR CONTINUATION REFER TO

MECHANICAL DRAWINGS

FOR CONTINUATION REFER TO

MECHANICAL DRAWINGS

CONNECT DCW

& DHW TO (E)

DCW & (E)DWH

3"SCW &

3"NPW UP

DCP-10-01-001

P-803

3/4"DCW

DROP

3/4"DCW

DROP

3/4"DCW

DROP

3/4"DCW

DROP

(E)2"DCW

(E)1 1/2"DHW

3/4"DCWR

3"DCW

3/4"DCWR

3/4"DCW

DROP

1"SCA DROP

TO 50' HOSE

REEL AT SHOP

BENCH

1"SCA UP

1"SCA

1"SCA FOR CONTINUATION

SEE ENLARGED PLAN

4"FD-E

4"FD-E

DOMESTIC

COLD

WATER

RECIRCULATION

PUMP

BLOW

DOWN

SEPERATOR

CONDENSATE

RECEIVER

CONDENSATE

STORAGE

TANK

FEEDWATER

PUMPS

FUEL

PUMP

SKID

FUEL

OIL

FILTERATION

3"V UP1 1/4"DCW &

1 1/4"DHW

DROP TO

MIXING VALVE

1 1/4"DHW

1 1/4"DCW

D C W

D H W

4"SAN

1"SCA 1"SCA

4"FD-E

CS-10-01-001

4"FD-E

2"SCW2"SCW

2"SCW FOR CONTINUATION

SEE MECHANICAL DRAWINGS2"SCW FOR CONTINUATION

SEE MECHANICAL DRAWINGS

CONTINUATION

TO BATHROOM

1"SCA

1"SCA

3"SCW FOR CONTINUATION

SEE ENLARGED PLAN

3"NPW

3"NPW

S C W

S C A

S C W

3"SCW

S C W

3"SCW

S C W

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t

NORTH

KEYPLAN

HAZARDOUS MATERIALS

MABBETT & ASSOCIATES, INC.

105 CENTRAL STREET, STONEHAM, MA 02180

PHONE: (781)275-6050

CIVIL / STRUCTURAL

LABELLA

303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614

PHONE: (585)454-6110

ARCHITECTURAL

OCULUS INC.

1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102

PHONE: (314)367-6100

ELECTRONIC SECURITY

GRW

801 CORPORATE DRIVE, LEXINGTON, KY 40503

PHONE: (859)223-3999

FIRE SUPPRESSION

KOFFEL ASSOCIATES

8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045

PHONE: (410)750-2246

PHYSICAL SECURITY

FORCE PROTECT SECURITY CONSULTANTS

10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407

PHONE: (502)836-4232

/1

/2

:3

:1

A

M

PP101

PLUMBING

PIPING PLAN

MAIN LEVEL

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

01-07-2022 PD AHTM0506-0011

100% CORRECTED

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"1 PIPING PLAN - MAIN LEVEL

GENERAL SHEET NOTES:

1. REFER TO DRAWING P-001 FOR PLUMBING SYMBOLS, ABBREVIATIONS, AND GENERAL

D

6.7 8 9 10

B

C

B.3

BB

DD

(E)3"V(E)3"V

(N)BOILER

(N)BOILER

(N)BOILER

D/A-10-03-001

DEAREATOR

BOILER LEVEL

CONTROL ROOM

4" V UP

EMERGENCY SHOWER/EYE WASH STATION

3"NPW

3/4"DHWR

1 1/2"DHW

3"DCW

SECURITY

IT

ANNEX

BOILER LEVEL

MAINTENACE

ADDITION

GENERATOR

ROOM

6"SD UP

3"V UP

3"SCW

DROP

3"NPW RISE

3"NPW

UP&DN

3"SCW RISE

4"FD-S 4"FD-S

4"FD-S

4"FD-S

3/4"DCWR

3/4"DHWR

1 1/2"DHW &

3"DCW

UP

3"NPW &

3"SCW

UP

3"DCW

1 1/2"DHW &

3/4"DHWR

3/4"DCWR

DN

3"NPW &

3"SCW

DN

(E)4"V

UP&DN

(E)3"SD

DROP

(E)3"SD

UP TO

(E)RD

(E)4"SD

UP&DN (E)3"SD

DROP

TRANSFORMER

2"V DN

3"V

B-10-02-001 B-10-02-002 B-10-01-003

4"V UP&DN

4" UP&DN

1 1/4"DCW

1 1/4"DHW

UP & DROP

TO MIXING VALVE

1"SCA DROP

TO 50FT

HOSE REEL

1"SCA DN

3"SCW

UP&DN

1"SCA UP

1"SCA DROP

1"SCA DN

1"SCA DN

1"SCA

3"SCW

3/4"DCWR

4" V UP

VTR

1" SAN

UP&DN

3"V UP

2"V DN

3"V UP

2"V DN

3"V UP

2"V DN

2"V DN

3"V RISE

3"NPW DN

3"SCW DN

3" SCW DN TO

CONDENSATE STORAGE

TANK

FOR CONTINUATION

REFER TO MECHANICAL

DRAWINGS.

3/4"DHWR

1 1/2"DHW &

3"DCW

UP & DN

3"NPW

DROP

3" SCW

FOR CONTINUATION

REFER TO MECHANICAL

DRAWINGS.

3"SCW

3"SCW

3"V

V

V

S C W

1"SCA

MP303

P-707

P-803P-803

3/4"DCW RISE3/4"DCW RISE

N P W

3"NPW

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t

NORTH

KEYPLAN

HAZARDOUS MATERIALS

MABBETT & ASSOCIATES, INC.

105 CENTRAL STREET, STONEHAM, MA 02180

PHONE: (781)275-6050

CIVIL / STRUCTURAL

LABELLA

303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614

PHONE: (585)454-6110

ARCHITECTURAL

OCULUS INC.

1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102

PHONE: (314)367-6100

ELECTRONIC SECURITY

GRW

801 CORPORATE DRIVE, LEXINGTON, KY 40503

PHONE: (859)223-3999

FIRE SUPPRESSION

KOFFEL ASSOCIATES

8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045

PHONE: (410)750-2246

PHYSICAL SECURITY

FORCE PROTECT SECURITY CONSULTANTS

10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407

PHONE: (502)836-4232

/1

/2

:3

:2

A

M

PP102

PLUMBING

PIPING PLAN

BOILER LEVEL

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

01-07-2022 Checker AHTM0506-0011

100% CORRECTED

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"1 PIPING PLAN - BOILER LEVEL

GENERAL SHEET NOTES:

1. REFER TO DRAWING P-001 FOR PLUMBING SYMBOLS, ABBREVIATIONS, AND GENERAL

D

6.7 8 9

B

C

B.3

BB

DD

E

1 1/2"DHW

1 1/2"DCW

(E)4"V

DEAREATOR

ECONOMIZER

(N)BOILER

(N)BOILER

ECONOMIZER

ECONOMIZER

(N)BOILER

1 1/2"DHW

DWH-10-03-001

3/4"DHWR

3"SCW DN

3"NPW DN

6"SD UP & DN

CATWALK LEVEL

ANNEX

CATWALK LEVEL

FHX-10-02-001 FHX-10-02-002 FHX-10-02-003

B-10-02-001 B-10-02-002 B-10-01-003

FOR CONTINUATION SEE

MECHANICAL DRAWINGS

FOR CONTINUATION SEE

MECHANICAL DRAWINGS

FOR CONTINUATION SEE

MECHANICAL DRAWINGS

1/2"SCW

1/2"SCW 1/2"SCW

4"V DN

4"V UP

4"V

DROP

FOR CONTINUATION SEE

MECHANICAL DRAWINGS

4"SD

4"SD UP

TO RD

4"SD UP

TO RD

4"SD

4"SD

4"V UP4"V DN

(E)3"SD UP

TO (E)RD

(E)3"SD DN

3"NPW

3"SCW

DN

2"DCW

1-1/2"DHW

3/4"DHWR

3/4"DCWR

DN

3/4"DHWR

1 1/2"DHW

3"DCW

3"DCW

1 1/2"DHW

3/4"DHWR

3"DCW

1 1/2"DHW

3/4"DHWR

1/8" / 1'-0"

3"DCW

1 1/2"DHW

3/4"DHWR

DHP-10-03-001

1"SCA DROP

TO 50FT

HOSE REEL

1"SCA DN

3"V DN3"V DN

3"V DN

3"SCW

1/2"SCW

3"SCW 3"SCW

S C W

1"SCW 1"SCW 1"SCW

1 1/4"DCW

1 1/4"DHW

DN

3/4"DCWR

3/4"DCWR

S C W

4"SD4"SD

3"NPW

3"NPW 3"NPW

N P W

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t

NORTH

KEYPLAN

HAZARDOUS MATERIALS

MABBETT & ASSOCIATES, INC.

105 CENTRAL STREET, STONEHAM, MA 02180

PHONE: (781)275-6050

CIVIL / STRUCTURAL

LABELLA

303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614

PHONE: (585)454-6110

ARCHITECTURAL

OCULUS INC.

1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102

PHONE: (314)367-6100

ELECTRONIC SECURITY

GRW

801 CORPORATE DRIVE, LEXINGTON, KY 40503

PHONE: (859)223-3999

FIRE SUPPRESSION

KOFFEL ASSOCIATES

8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045

PHONE: (410)750-2246

PHYSICAL SECURITY

FORCE PROTECT SECURITY CONSULTANTS

10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407

PHONE: (502)836-4232

/1

/2

:3

:2

A

M

PP103

PLUMBING

PIPING PLAN

CATWALK LEVEL

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

01-07-2022 PD AHTM0506-0011

100% CORRECTED

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"1

PIPING PLAN - CATWALK LEVEL

GENERAL SHEET NOTES:

1. REFER TO DRAWING P-001 FOR PLUMBING SYMBOLS, ABBREVIATIONS, AND GENERAL

D

6.7 8 9 10

B

C

B.3

BB

DD

(E)4"V

4"RD-1

3"RD-1

3"RD-1

4"RD-1

4"VTR

3"VTR

4"VTR

4"VTR

4"VTR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t

NORTH

KEYPLAN

HAZARDOUS MATERIALS

MABBETT & ASSOCIATES, INC.

105 CENTRAL STREET, STONEHAM, MA 02180

PHONE: (781)275-6050

CIVIL / STRUCTURAL

LABELLA

303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614

PHONE: (585)454-6110

ARCHITECTURAL

OCULUS INC.

1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102

PHONE: (314)367-6100

ELECTRONIC SECURITY

GRW

801 CORPORATE DRIVE, LEXINGTON, KY 40503

PHONE: (859)223-3999

FIRE SUPPRESSION

KOFFEL ASSOCIATES

8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045

PHONE: (410)750-2246

PHYSICAL SECURITY

FORCE PROTECT SECURITY CONSULTANTS

10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407

PHONE: (502)836-4232

/1

/2

:3

:2

A

M

PP104

PLUMBING

PIPING PLAN

ROOF

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

01-07-2022 PD AHTM0506-0011

100% CORRECTED

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"1

PIPING PLAN - ROOF LEVEL

GENERAL SHEET NOTES:

1. REFER TO DRAWING P-001 FOR PLUMBING SYMBOLS, ABBREVIATIONS, AND GENERAL

NOTES.

GENERAL SHEET NOTES:

1. REFER TO DRAWING P-001 FOR PLUMBING SYMBOLS, ABBREVIATIONS, AND GENERAL

D

6.7 8 9 10

C

B.3

BB

DD

BT-10-01-001

WS-10-01-001

(E)FD

ACB-10-002

P-707

PWP-10-01-001

(E)4"FD

(E)4"FD

4"FD-E

BOILER WATER TREAMENT.

REFER TO MECHANICAL

DRAWINGS FOR

ADDITIONAL INFORMATION.

P-531

4"ICW RISE

4"ICW DROP

4"ICW RISE

W/SOV & DN

4"ICE RISE

4"SAN

RISE&DN

(E)2"SAN UP

TO (E)FD

1/2"DCW &

1/2"DHW DROP

IN WALL

1-1/2"DCW &

1-1/2"DHW DROP TO

EMERGENCY SHOWER

4"FCO

(E)4"SD

UP&DN

(E)4"FCO

(E)4"V

DROP&UP

RELOCATED (E)AIR

COMPRESSOR

RECEIVER EQUIPMENT

6"FIRE WATER RISE&DN.

REFER TO FIRE

PROTECTION DRAWINGS

FOR CONTINUATION.

(E)4"FCO

2" V

DROP IN WALL

2"V

UP

3" SCW UP

3"DCW

1 1/2" DHW

3/4"DHWR

3/4"DCWR

UP

1"SCA UP

1"SCA UP

(E)10-ACR-03

ACB-10-01-001

4"FD-E

4"ICW

3"DCW

4"ICW

1"SCA

3"DCW

RPZ-10-01-004

3"SCW

3"NPW

3"SCW

4"NPW

2"DCW

1 1/2"DHW

3/4"DCWR

3/4"DHWR

1 1/2"DHW

1/2"DCW1 1/2"V

1/2"DHW

3"NPW

(E)2"SAN

1"SCA

1"SCA

(E)1"SCA

1"SCA

(E)2"SAN

(E)3"DCW

NC

PROCESS

WATER

PUMPS

WATER

SOFTENER

AIR

COMPRESSOR

(E)AIR

COMPRESSOR

BRINE

TANK

FOR CONTINUATION

REFER TO PP101

(E)4"FD

3" NPW UP

3"NPW

3"SCW

WATER METER3"DCW

NC

ROUTED HIGH

AT FLR ABOVE

3"SCW

3"WATER TO

TEMPORARY

BOILERS

3"DCW

D C W

2" DRAIN

DOWN TURNED

TOWARD FD.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t

NORTH

KEYPLAN

HAZARDOUS MATERIALS

MABBETT & ASSOCIATES, INC.

105 CENTRAL STREET, STONEHAM, MA 02180

PHONE: (781)275-6050

CIVIL / STRUCTURAL

LABELLA

303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614

PHONE: (585)454-6110

ARCHITECTURAL

OCULUS INC.

1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102

PHONE: (314)367-6100

ELECTRONIC SECURITY

GRW

801 CORPORATE DRIVE, LEXINGTON, KY 40503

PHONE: (859)223-3999

FIRE SUPPRESSION

KOFFEL ASSOCIATES

8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045

PHONE: (410)750-2246

PHYSICAL SECURITY

FORCE PROTECT SECURITY CONSULTANTS

10901 FRONT BEACH RD, STE 1415, PANAMA CITY BEACH, FL 32407

PHONE: (502)836-4232

/1

/2

:3

:3

A

M

PP401

ENLARGED PIPING PLAN REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

01-07-2022 GE AO0506-0011

100% CORRECTED

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/2" = 1'-0"1

ENLARGED PIPING PLAN - ANNEX LEVEL

NO. DESCRIPTION DATE

B

A

C

D

E

F

1 2 3 4 5 6 87 9

97 8654321

MILLER-REMICK LLC

PROFESSIONAL ENGINEER

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE

WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE

PROFESSIONAL ENGINEER.

Miller-Remick LLC

1010 KINGS HIGHWAY SOUTH

CHERRY HILL, NEW JERSEY 08034

PHONE: (856)429-4000

FAX: (856)429-5002

M.E.P. & Structural Engineering

A Service Disabled Veteran Owned Small Business

B

A

C

D

E

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ENGINEER OF RECORDCONSULTANT

Project Director

MR PROJECT NO: 0506-0011

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

100% CORRECTED

CONSTRUCTION DOCUMENTS

01-07-2022

PLUMBING

DETAILS

P-501

AHTMGE

B

A

C

D

E

F

1 2 3 4 5 6 87 9

97 8654321

MILLER-REMICK LLC

PROFESSIONAL ENGINEER

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE

WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE

PROFESSIONAL ENGINEER.

Miller-Remick LLC

1010 KINGS HIGHWAY SOUTH

CHERRY HILL, NEW JERSEY 08034

PHONE: (856)429-4000

FAX: (856)429-5002

M.E.P. & Structural Engineering

A Service Disabled Veteran Owned Small Business

B

A

C

D

E

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ENGINEER OF RECORDCONSULTANT

Project Director

MR PROJECT NO: 0506-0011

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

100% CORRECTED

CONSTRUCTION DOCUMENTS

01-07-2022

PLUMBING

DETAILS

P-502

50,000 GALLON

WATER STORAGE TANK

NO. DESCRIPTION DATE

B

A

C

D

E

F

1 2 3 4 5 6 87 9

97 8654321

MILLER-REMICK LLC

PROFESSIONAL ENGINEER

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE

WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE

PROFESSIONAL ENGINEER.

Miller-Remick LLC

1010 KINGS HIGHWAY SOUTH

CHERRY HILL, NEW JERSEY 08034

PHONE: (856)429-4000

FAX: (856)429-5002

M.E.P. & Structural Engineering

A Service Disabled Veteran Owned Small Business

B

A

C

D

E

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ENGINEER OF RECORDCONSULTANT

Project Director

MR PROJECT NO: 0506-0011

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

100% CORRECTED

CONSTRUCTION DOCUMENTS

01-07-2022

PLUMBING

SOFTENED WATER FLOW DIAGRAM

P-601

B

A

C

D

E

F

1 2 3 4 5 6 87 9

97 8654321

MILLER-REMICK LLC

PROFESSIONAL ENGINEER

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE

WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE

PROFESSIONAL ENGINEER.

Miller-Remick LLC

1010 KINGS HIGHWAY SOUTH

CHERRY HILL, NEW JERSEY 08034

PHONE: (856)429-4000

FAX: (856)429-5002

M.E.P. & Structural Engineering

A Service Disabled Veteran Owned Small Business

B

A

C

D

E

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ENGINEER OF RECORDCONSULTANT

Project Director

MR PROJECT NO: 0506-0011

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

100% CORRECTED

CONSTRUCTION DOCUMENTS

01-07-2022

PLUMBING

FLOW & RISER

DIAGRAMS

P-602

B

A

C

D

E

F

1 2 3 4 5 6 87 9

97 8654321

MILLER-REMICK LLC

PROFESSIONAL ENGINEER

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE

WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE

PROFESSIONAL ENGINEER.

Miller-Remick LLC

1010 KINGS HIGHWAY SOUTH

CHERRY HILL, NEW JERSEY 08034

PHONE: (856)429-4000

FAX: (856)429-5002

M.E.P. & Structural Engineering

A Service Disabled Veteran Owned Small Business

B

A

C

D

E

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ENGINEER OF RECORDCONSULTANT

Project Director

MR PROJECT NO: 0506-0011

REPLACE BOILERS IN BUILDING 10

830 CHALKSTONE AVENUE

PROVIDENCE, RI 02908

650-19-100

100% CORRECTED

CONSTRUCTION DOCUMENTS

01-07-2022

PLUMBING

SCHEDULES

P-701

File details come from the government source that posted it. Updated .