S02 BD03252022 Drawings - 2a_Civil - Part 1.pdf
PDF 17 MB Posted
- Attached to
- Y1NB--650-19-100 Replace Boilers in Bldg 10 Federal contract opportunity
- Solicitation number
- 36C24122R0084
About this file
This document provides details on a federal contract opportunity from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1. The solicitation number is 36C24122R0084 and seeks to replace boilers in Building 10. As indicated in the attached RFP, the agency is seeking contractor services to replace existing boilers. The opportunity type is listed as a solicitation. No other salient details are provided in the document.
View the file
Other files for this federal contract opportunity
Show all 50
Y1NB--650-19-100 Replace Boilers in Bldg 10 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEGEND
DRAWING INDEX
1. SITE DRAINAGE, INCLUDING THE PROJECT SITE AND ADJACENT PRIVATE AND PUBLIC
ROADWAYS, DRIVES, PARKING AREAS OR PROPERTIES SHALL BE MAINTAINED
THROUGHOUT THE CONSTRUCTION PERIOD.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING ALL MATERIALS, TOOLS AND
EQUIPMENT, INCLUDING SPECIAL CUTTING DEVICES, NECESSARY TO PERFORM THE
WORK CONTAINED IN THIS CONTRACT.
3. THE SIZES AND MATERIAL OF CONSTRUCTION OF WATER MAINS, SANITARY SEWERS AND
STORM SEWERS TO REMAIN ARE REPUTED. THE CONTRACTOR SHALL VERIFY SIZES OF
ALL UTILITIES WHERE CONNECTIONS TO SAID EXISTING UTILITIES ARE REQUIRED.
EXCAVATION TO VERIFY THESE UTILITIES SHALL BE MADE AT NO ADDITIONAL COST TO
THE OWNER.
4. THE CONTRACTOR SHALL PROTECT ALL EXISTING SITE AMENITIES NOT DESIGNATED FOR
REMOVAL.
5. UNLESS OTHERWISE INDICATED ON THE PLANS OR DIRECTED BY THE
ARCHITECT/ENGINEER, THE CONTRACTOR IS RESPONSIBLE FOR PRESERVING AND
PROTECTING FROM DAMAGE ALL TREES, SHRUBS AND PLANTS IN THE VICINITY OF THE
PROPOSED WORK.
6. THE CONTRACTOR SHALL PROTECT AND SUPPORT ALL EXISTING UTILITIES DESIGNATED
TO REMAIN FOR THE DURATION OF THE CONTRACT.
7. ANY SITE AMENITY, UTILITY, STREET APPURTENANCE, OR OTHER ITEM WHICH BECOMES
DAMAGED AS A RESULT OF THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED OR
REPLACED IN-KIND BY THE CONTRACTOR AS DETERMINED BY THE PROJECT MANAGER
OR ARCHITECT/ENGINEER AND AT NO ADDITIONAL COST TO THE OWNER.
8. THE DEPARTMENT OF VETERANS AFFAIRS STANDARD SPECIFICATIONS, CONSTRUCTION
SAFETY AND SECURITY REQUIREMENTS SHALL BE ADHERED TO AS FULLY AND
COMPLETELY AS IF ATTACHED HERETO.
9. THE CONTRACTOR SHALL MAKE ALL NECESSARY CONSTRUCTION NOTIFICATIONS AND
APPLY FOR OR OBTAIN ALL NECESSARY CONSTRUCTION/ENVIRONMENTAL PERMITS AND
COORDINATE WITH THE ENGINEER OF RECORD AND OWNER'S REPRESENTATIVE.
10. CONTRACTOR SHALL PROVIDE NOISE AND VIBRATION MITIGATION MEASURES DURING
CONSTRUCTION, AS DESCRIBED IN SPECIFICATION 01 56 19 CONSTRUCTION NOISE AND
VIBRATION CONTROL.”
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. NO
ALLOWANCE WILL BE MADE FOR ADDITIONAL COSTS DUE TO CONTRACTOR'S FAILURE TO
VERIFY EXISTING CONDITIONS AND DIMENSIONS.
2. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY DIG SAFE
RHODE ISLAND AT 811 TO REQUEST UTILITY STAKEOUT OF ALL PUBLIC UTILITIES.
3. WORK ASSOCIATED WITH THIS CONTRACT WILL OCCUR AT AN ACTIVE AND FUNCTIONAL
FACILITY. CONTRACTOR SHALL COORDINATE WITH THE OWNER TO MINIMIZE DISRUPTION
TO THE OPERATIONS OF THE FACILITY. CONTRACTOR SHALL BE SOLELY RESPONSIBLE TO
PROVIDE A SAFE WORK SITE AND TO PROTECT THE PUBLIC, VISITORS AND EMPLOYEES
FROM HARM AS A RESULT OF HIS CONSTRUCTION ACTIVITIES.
4. THE HORIZONTAL AND VERTICAL LOCATION OF ALL EXISTING ABOVE GROUND AND
BELOW GROUND UTILITIES, STRUCTURES, AND APPURTENANCES SHOWN ON THE PLANS
ARE APPROXIMATE AND ARE NOT GUARANTEED. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR DETERMINING THE EXACT HORIZONTAL AND VERTICAL LOCATION OF
ALL UTILITIES, STRUCTURES, AND APPURTENANCES IN THE PATH OF AND ADJACENT TO
THE PROPOSED WORK.
5. SITE DRAINAGE, INCLUDING THE PROJECT SITE AND ADJACENT PRIVATE AND PUBLIC
ROADWAYS, DRIVES, PARKING AREAS OR PROPERTIES SHALL BE MAINTAINED
THROUGHOUT THE CONSTRUCTION PERIOD.
6. CONTRACTOR SHALL PROTECT AND SUPPORT ALL EXISTING UTILITIES DESIGNATED TO
REMAIN FOR THE DURATION OF THE CONTRACT.
7. THE CONTRACTOR SHALL NOTIFY THE LOCAL GOVERNMENT AND LOCAL FIRE
DEPARTMENT AS NECESSARY AND SHALL OBTAIN ANY REQUIRED PERMITS PRIOR TO
BEGINNING WORK. COPIES OF ANY REQUIRED PERMITS SHALL BE PROVIDED TO THE
OWNER PRIOR TO BEGINNING THE WORK.
8. CONTRACTOR SHALL REMOVE FROM SITE, MATERIALS NOT INDICATED TO BE SALVAGED
INCLUDING ALL DEBRIS. ALL REMOVED MATERIALS SHALL BECOME THE PROPERTY OF
CONTRACTOR WHO SHALL LEGALLY DISPOSE OF SAME.
9. ALL TREES, SHRUBS AND PLANTS DESIGNATED TO REMAIN AND DISTURBED BY
CONSTRUCTION OPERATIONS, SHALL BE REPLACED IN-KIND AS DIRECTED BY THE
ARCHITECT/ENGINEER AND/OR OWNER'S DESIGNATED REPRESENTATIVE AT NO
ADDITIONAL COST TO THE OWNER.
10. THE CONTRACTOR SHALL MAINTAIN SAFE VEHICULAR AND PEDESTRIAN ACCESS TO THE
EXISTING BUILDINGS FOR THE DURATION OF THE CONTRACT.
11. WHEN EXISTING CONSTRUCTION WHICH IS TO REMAIN IS DAMAGED DURING THE
COURSE OF CONSTRUCTION AS A RESULT OF CONTRACTORS WORK, IT SHALL BE
REPAIRED AND/OR REPLACED WITH SIMILAR OR LIKE MATERIALS AS MUCH AS POSSIBLE,
AT NO COST TO THE OWNER. ALL REPAIRS AND/OR REPLACEMENTS WILL BE SUBJECT TO
OWNERS APPROVAL.
12. COORDINATE LOCATION OF TEMPORARY CONSTRUCTION FENCE AND TEMPORARY STONE
STAGING AREA WITH OWNER
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. NO
ALLOWANCE WILL BE MADE FOR ADDITIONAL COSTS DUE TO CONTRACTOR'S FAILURE TO
VERIFY EXISTING CONDITIONS.
2. THE CONTRACTOR SHALL LOCATE, MARK, SAFEGUARD AND PRESERVE ALL SURVEY
MARKERS AND RIGHT-OF-WAY MARKERS IN THE AREA OF CONSTRUCTION.
3. ANY IRON PINS, MONUMENTS OR OTHER ITEMS DEFINING PROPERTY LINES WHICH ARE
DISTURBED BY CONSTRUCTION OPERATIONS SHALL BE PROPERLY TIED AND
ACCURATELY RESET BY AN RI LICENSED SURVEYOR UPON COMPLETION OF THE WORK.
4. HORIZONTAL DATUM BASED OFF NAD83 RHODE ISLAND STATE PLANE.
5. VERTICAL BASED OFF OF NAVD88.
6. TOPOGRAPHIC SURVEY PROVIDED BY CROSSMAN ENGINEERING MAY 2020, UPDATED IN
MAY 2021.
1. THE CONTRACTOR SHALL CONFORM TO THE REQUIREMENTS OF OSHA, AND ANY OTHER
AGENCY HAVING JURISDICTION WITH REGARD TO SAFETY PRECAUTIONS WITH
TRENCHING OPERATIONS. THE REQUIREMENTS SET FORTH HEREIN ARE INTENDED TO
SUPPLEMENT REQUIREMENTS ESTABLISHED BY THESE AGENCIES. IN THE CASE OF A
CONFLICT BETWEEN REQUIREMENTS OF OTHER JURISDICTIONAL AGENCIES AND THESE
DOCUMENTS, THE MORE STRINGENT REQUIREMENT ON THE CONTRACTOR SHALL APPLY.
2. SHEETING, IF REQUIRED DURING CONSTRUCTION, IS CONSIDERED TO BE PART OF THIS
CONTRACT AND SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER.
3. ALL TRENCHES THROUGH PAVEMENT SHALL BE SAW CUT PRIOR TO EXCAVATION AND
AGAIN PRIOR TO PAVEMENT RESTORATION.
4. CONTRACTOR SHALL ADJUST THE RIMS OF ALL MANHOLES, CATCH BASINS, VALVE
BOXES AND OTHER UTILITY SITE STRUCTURES TO MEET FINISHED GRADE IN AREAS
REQUIRING REPAVING OR REGRADING AS PART OF THE WORK, INCLUDING THOSE THAT
MAY NOT BE SHOWN ON THE PLANS.
5. VOIDS LEFT BY UTILITY OR STRUCTURE REMOVAL OR GRUBBING OPERATIONS SHALL BE
BACKFILLED AND PROPERLY COMPACTED WITH STRUCTURAL FILL IN AREAS UNDER AND
WITHIN 5 FEET HORIZONTALLY OF ALL STRUCTURES, BUILDINGS AND PAVEMENTS. IN
GRASSED AREAS, VOIDS LEFT SHALL BE FILLED AND PROPERLY COMPACTED WITH
SUITABLE ON-SITE OR IMPORTED EARTHEN BACKFILL. ALL DISTURBED AREAS SHALL BE
RESTORED.
6. THE CONTRACTOR SHALL DEWATER ALL EXCAVATIONS TO PREVENT THE INTRODUCTION
OF GROUNDWATER INTO THE TRENCHES/EXCAVATIONS. PROVIDE ALL EQUIPMENT
NECESSARY TO MAINTAIN THE GROUNDWATER LEVEL AS NECESSARY.
7. THE CONTRACTOR SHALL PLACE AT MINIMUM 6 INCHES OF CLEANED SCREENED
TOPSOIL IN ALL DISTURBED AREAS PRIOR TO SEEDING. VEGETATIVE COVER OF
DISTURBED AREAS SHALL BE ESTABLISHED BY CONTRACTOR. SEED MIX SHALL BE A
SEASONALLY AND LOCALLY APPROPRIATE GRASS BLEND.
1. ALL EROSION CONTROL MEASURES SHALL BE IN ACCORDANCE WITH RHODE ISLAND
STANDARDS AND SPECIFICATIONS FOR EROSION AND SEDIMENT CONTROL, AND LOCAL
GOVERNING SOIL AND WATER CONSERVATION AGENCY RECOMMENDATIONS AND
STANDARDS. CONTRACTOR SHALL SUBMIT PROPOSED EROSION CONTROL PLAN
INCLUDING SEQUENCING OF WORK TO THE ENGINEER FOR REVIEW PRIOR TO START OF
WORK.
2. UTILIZE CONSTRUCTION METHODS/TECHNIQUES, WHICH WILL LIMIT THE EXPOSED
EARTHEN AREAS AND MINIMIZE THE EFFECT OF EARTH DISTURBANCE ACTIVITIES ON SOIL
EROSION. THE AREA OF DISTURBANCE SHALL BE LIMITED TO A MAXIMUM OF 1 ACRES
UNLESS OTHERWISE APPROVED BY THE ENGINEER.
3. ALL SEDIMENTATION BARRIERS AND OTHER TEMPORARY OR PERMANENT MEASURES
SHALL BE IN PLACE PRIOR TO THE START OF CONSTRUCTION. PLANS SHOW THE
SUGGESTED MINIMUM MEASURES REQUIRED.
4. REMOVAL OF ALL TEMPORARY EROSION AND SEDIMENTATION CONTROL MEASURES
SHALL BE COMPLETED AT THE APPROVAL OF THE OWNER AND ENGINEER. THE COST OF
REMOVING THESE MEASURES SHALL ALSO BE INCLUDED IN THE BID PRICE.
5. FOR THE DURATION OF THE PROJECT, THE CONTRACTOR SHALL PROTECT ALL ON-SITE,
ADJACENT AND/OR DOWNSTREAM STORM/SANITARY SEWERS, AND/OR OTHER WATER
COURSES FROM CONTAMINATION BY WATER BORNE SILTS, SEDIMENTS, FUELS,
SOLVENTS, LUBRICANTS OR OTHER POLLUTANTS ORIGINATING FROM ANY WORK DONE
ON, OR IN SUPPORT OF THIS PROJECT.
6. DURING CONSTRUCTION NO WET OR FRESH CONCRETE OR LEACHATE SHALL BE
ALLOWED TO ESCAPE INTO STORM/SANITARY SEWERS, DITCHES OR OTHER WATERS OF
RHODE ISLAND STATE, NOR SHALL WASHINGS FROM CONCRETE TRUCKS, MIXERS OR
OTHER DEVICES BE ALLOWED TO ENTER ANY STORM/SANITARY SEWERS, DITCHES,
RIVERS, OR WATER COURSES.
7. ALL EXCAVATED OR IMPORTED EARTHEN STOCKPILES SHALL BE SUITABLY STABILIZED
AND PROTECTED BY SILT FENCE SO THAT IT CANNOT REASONABLY ENTER ANY WATER
BODY, OR STORM OR SANITARY SEWER.
8. ALL METHODS AND EQUIPMENT PROPOSED BY THE CONTRACTOR TO ACCOMPLISH THE
WORK FOR EROSION AND POLLUTION CONTROL SHALL BE SUBJECT TO APPROVAL OF
THE ENGINEER.
9. THE CONTRACTOR SHALL BE REQUIRED TO TREAT TRAVELED AREAS TO CONTROL DUST.
WATER SHALL BE APPLIED TO SUCH TRAVELED AREAS AS THE ARCHITECT/ENGINEER OR
OWNER'S DESIGNATED REPRESENTATIVE MAY DESIGNATE. THE NUMBER OF
APPLICATIONS AND THE AMOUNT OF WATER SHALL BE BASED UPON FIELD AND
WEATHER CONDITIONS.
10. ALL AREAS OF SOIL DISTURBANCE RESULTING FROM THIS PROJECT WHICH WILL NOT BE
SUBJECT TO FURTHER EARTHWORK OR CONSTRUCTION ACTIVITIES SHALL BE
PERMANENTLY SEEDED TO ESTABLISH GRASS, AND MULCHED WITH HAY OR STRAW
WITHIN ONE WEEK OF FINAL DISTURBANCE. MULCH SHALL BE MAINTAINED UNTIL A
SUITABLE VEGETATIVE COVER IS ESTABLISHED.
11. CONTRACTOR STAGING AREAS AND CONSTRUCTION ENTRANCE LOCATIONS SHALL BE
COORDINATED WITH THE OWNER PRIOR TO START OF CONSTRUCTION. STABILIZED
CONSTRUCTION ENTRANCE(S), AS SHOWN ON THE PLANS SHALL BE PROVIDED. ALL
DISTURBED AREAS SHALL BE RESTORED.
12. ALL CATCH BASINS/DRAINAGE INLETS SHALL HAVE STONED INLET PROTECTION AROUND
THEM AND GEOTEXTILE FABRIC OVER THE GRATE TO PREVENT SEDIMENTATION FROM
ENTERING THE STORM SYSTEM.
13. TILL ALL COMPACTED SOILS LOCATED IN LAWN AREAS TO RESTORE THE ORIGINAL
PROPERTIES OF THE SOIL PRIOR TO SEEDING.
14. CONTRACTOR SHALL INSPECT, MAINTAIN, REPLACE AS NEEDED, REMOVE, ETC. EROSION
AND SEDIMENT CONTROL MEASURES.
GRADING NOTES
EROSION AND SEDIMENT CONTROL NOTES
GENERAL NOTES
SURVEY NOTES
DEMOLITION NOTES
C001 GENERAL NOTES, LEGEND, AND DRAWING INDEX
C101A EXISTING CONDITIONS AND DEMOLITION PLAN
C101B EXISTING CONDITIONS AND DEMOLITION PLAN
C201A SITE PLAN
C201B SITE PLAN
C301A UTILITY PLAN
C301B UTILITY PLAN
C401A GRADING AND EROSION CONTROL PLAN
C401B GRADING AND EROSION CONTROL PLAN
C402A RETAINING WALL DETAILS
C402B RETAINING WALL DETAILS
C403 RETAINING WALL DETAILS
C404 BORING LOGS
C405 BORING LOGS
C501 CONSTRUCTION DETAILS
C502 CONSTRUCTION DETAILS
C503 CONSTRUCTION DETAILS
EXISTING PROPOSED DESCRIPTION
PROJECT BENCHMARK / CONTROL
POINTS
UTILITY DEMOLITION
CHAIN LINK FENCE DEMOLITION
SAWCUT
TREE PROTECTION
TREE DEMOLITION
X X X X
BORING LOCATIONS
TREE/VEGETATION LIMIT
CHAIN LINK FENCE
BUILDING/STRUCTURE
PROPERTY LINE
BLDG
RETAINING WALL / WALL
SIGN
BOLLARD
HYDRANT
VALVE
CATCH BASIN
STORM SEWER CLEAN OUT
DOWN SPOUTDS
MANHOLE
ST CO
ELECTRIC HANDHOLE
ELECTRIC MANHOLE
ST ST
UD UD UD
STORM LINE
WATER LINE
OVERHEAD ELECTRIC
STORM UNDERDRAIN PIPE
UE UE
W W
UNDERGROUND ELECTRIC
G GAS LINE
SANITARY LINESA SA
OE OE
MAJOR CONTOUR510
MINOR CONTOUR
℄ OF DRAINAGE SWALE
EROSION FENCE
SILT SOCK INLET PROTECTION
FLOW/SLOPE DIRECTION
STABILIZED CONSTRUCTION ENTRANCE
(TEMPORARY)
LIGHT POLE SINGLE HEAD
1. SUBGRADE COMPACTED TO 95% PROCTOR SHALL BE UTILIZED UNDERNEATH
CONSTRUCTION OF PAVEMENT AND CONCRETE BASES.
2. ALL STAKEOUT FOR THE PROPOSED SITE IMPROVEMENTS SHALL BE COMPLETED BY A
RHODE ISLAND STATE LICENSED LAND SURVEYOR.
3. IF ANY DISCREPANCIES ARE NOTED BETWEEN THESE CONSTRUCTION DOCUMENTS AND
INFORMATION PROVIDED OR AN ERROR IS SUSPECT, IT SHALL BE IMMEDIATELY
REPORTED TO THE CONSTRUCTION MANAGER AND THE MILLER-REMICK PROJECT
MANAGER IN WRITING.
4. ANY PROOF-ROLLING OF EXPOSED SUBBASE BY A MINIMUM 10 TON SMOOTH DRUM
ROLLER SHALL BE DONE UNDER THE GUIDANCE OF, AND OBSERVED BY, QUALIFIED
ENGINEERING PERSONNEL PRIOR TO PLACEMENT OF SUBBASE MATERIAL. THE ROLLER
SHOULD BE OPERATED IN THE STATIC MODE AND COMPLETE AT LEAST TWO (2) PASSES
OVER THE EXPOSED SUBGRADES.
SITE NOTES
SANITARY SEWER CLEAN OUTSA CO
1. FERTILIZER
1.1. LIME AND FERTILIZER SHALL BE APPLIED AFTER SEEDING PER RIDOT SPECIFICATION
L.02.03.3 AND L.02.03.4. LIME AND FERTILIZER SHALL BE THOROUGHLY
INCORPORATED INTO THE SOIL BY RAKING.
2. SEED - EROSION CONTROL AND LAWN MIX
2.1. GRADE A QUALITY, FRESH AND RECLEANED AND PROVEN TO PRODUCE
SATISFACTORY GROWTH IN THE LOCALITY OF THE PROJECT.
2.2. SEED MIX: FRESH, CLEAN AND FROM CURRENT SEASON'S CROP, DELIVERED IN
ORIGINAL PACKAGES, UNOPENED, AND BEARING GUARANTEED ANALYSIS. SEED
SHALL MEET RHODE ISLAND DOT SPECIFICATIONS. REFER TO RIDOT SECTION L.02
FOR SEED MIX TYPES, APPLICATIONS, AND SEASONAL WINDOWS. SHALL BE FREE
OF: POA ANNUA, BENT GRASS, AND NOXIOUS WEED SEED SUCH AS CANADIAN
THISTLE, COARSE FESCUE, EUROPEAN BINDWEED, JOHNSON GRASS AND LEAFY
SPURGE. THE LANDSCAPE CONTRACTOR SHALL FURNISH TO THE
ARCHITECT/ENGINEER A SIGNED STATEMENT CERTIFYING THAT THE SEED
FURNISHED IS FROM A LOT THAT HAS BEEN TESTED BY A RECOGNIZED
LABORATORY. SEED WHICH HAS BECOME WET, MOLDY OR IN ANY OTHER WAY
DAMAGED IN TRANSIT OR STORAGE, WILL NOT BE ACCEPTED.
3. MULCH
3.1. PER RIDOT, CELLULOSE FIBER MULCH SHALL BE USED. CELLULOSE FIBER MULCH
SHALL CONFORM TO RIDOT SUBSECTION M.18.07.1. E
4. WATER
4.1. FREE OF SUBSTANCE HARMFUL TO PLANT GROWTH. HOSES, PUMPS, SPRINKLERS
OR OTHER METHODS OF TRANSPORTATION FURNISHED BY CONTRACTOR.
5. TOPSOIL (SEE DIVISION 31 SECTION “EARTH MOVING”)
5.1. GENERAL TOPSOIL
5.1.1. APPROVED TOPSOIL, OBTAINED FROM EXCAVATION AND GRADING WORK OR
IF INSUFFICIENT MATERIAL (EITHER QUANTITY AND/OR QUALITY) IS
AVAILABLE, IT SHALL BE IMPORTED. ALL TOPSOIL SHALL BE DEPTH AS
INDICATED UNDER SPREADING TOPSOIL OF THIS SPECIFICATION.
5.1.2. TOPSOIL SHALL BE NATURAL, FRIABLE, FERTILE SOIL, CHARACTERISTIC OF
PRODUCTIVE SOIL IN THE VICINITY, REASONABLY FREE OF STONES, CLAY
LUMPS, ROOTS AND OTHER FOREIGN MATTER.
5.1.3. STORE TOPSOIL SEPARATELY FROM ALL OTHER EXCAVATED MATERIALS
ON-SITE AND PRESERVE FOR REUSE OR REPLACE WITH IMPORTED TOPSOIL
MEETING THE REQUIREMENTS OF DIVISION 31 SECTION “EARTH MOVING”.
5.1.4. STOCKED OR FURNISHED TOPSOIL SHALL BE TESTED BY AN APPROVED
SOIL-TESTING LABORATORY FOR DETERMINATION OF CORRECT LIME
FERTILIZER ADDITIVES. SUBMIT MECHANICAL AND CHEMICAL ANALYSIS OF
OFF-SITE TOPSOIL TO THE ARCHITECT/ENGINEER FOR APPROVAL PRIOR TO
DELIVERY OF TOPSOIL TO THE SITE. IF MORE THAN ONE SOURCE WILL BE
USED, PROVIDE AN ANALYSIS OF EACH SOURCE.
5.1.5. TOPSOIL SOURCE: IMPORTED TOPSOIL SHALL MEET THE REQUIREMENTS OF
DIVISION 31 SECTION “EARTH MOVING”. IMPORT TOPSOIL OR MANUFACTURED
TOPSOIL FROM OFF-SITE SOURCES. OBTAIN TOPSOIL DISPLACED FROM
NATURALLY WELL-DRAINED CONSTRUCTION OR MINING SITES WHERE
TOPSOIL OCCURS AT LEAST 6 INCHES DEEP; DO NOT OBTAIN FROM
AGRICULTURAL LAND, BOGS OR MARSHES.
LAWN RESTORATION NOTES
EXISTING PROPOSED DESCRIPTION
FUEL LINEFUEL FUEL
STEAM
HH
E
STEAM
o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t 4 o n e q u a rt e r in ch o n e f o o t
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Ser v ic e
D i s ab l e d Vet er an Owned Sma ll Business
SDVOSB
CVE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANT
Project Director
MR PROJECT NO: 0506-0011
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246 10
100% CORRECTED
CONSTRUCTION DOCUMENTS
01-07-2022
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD., STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502) 836-4232
LI CENSED PROFESSIONA
L
EN
GI
NE
ER
STA
TE O
F NEW YORK
0 9 4 6 7 4
CIVIL
GENERAL NOTES AND LEGEND
C001
LMRRJS
DRAWING INDEX
C001 GENERAL NOTES AND LEGEND
C002 STAGING PLAN
C101 EXISTING CONDITIONS AND DEMOLITION PLAN
C201 SITE PLAN
C301 UTILITY PLAN
C401 GRADING AND EROSION CONTROL PLAN
C402 RETAINING WALL DETAILS
C403 RETAINING WALL DETAILS
C404 BORING LOGS
C405 BORING LOGS
C501 CONSTRUCTION DETAILS
C502 CONSTRUCTION DETAILS
C503 CONSTRUCTION DETAILS
C504 CONSTRUCTION DETAILS
LIMIT OF
DISTURBANCE (TYP.)
LIMIT OF DISTURBANCE (TYP.)
RD
NEW TEMPORARY CONSTRUCTION FENCING.
FINAL FENCING AND GATE LOCATIONS TO BE
DETERMINED BY CONTRACTOR. CONTRACTOR
SHALL COORDINATE WITH BUILDING MANAGERS
TO ENSURE ADEQUATE ACCESS TO BUILDING
ENTRANCES AND LOADING DOCKS
NEW TEMPORARY CONSTRUCTION FENCING.
FINAL FENCING AND GATE LOCATIONS TO BE
DETERMINED BY CONTRACTOR
CONTRACTOR TO DEVELOP WORK ZONE
TRAFFIC CONTROL PLAN TO MAINTAIN
VEHICULAR TRAFFIC AND SAFETY ALONG
AIR FORCE DRIVE DURING DURATION OF
CONSTRUCTION. FULL ACCESS TO AIR
FORCE DRIVE TO BE RESTORED AS SOON
AS POSSIBLE.
CONTRACTOR TO DEVELOP WORK ZONE
TRAFFIC CONTROL PLAN TO MAINTAIN
VEHICULAR TRAFFIC AND SAFETY ALONG
AIR FORCE DRIVE DURING DURATION OF
CONSTRUCTION. FULL ACCESS TO AIR
FORCE DRIVE TO BE RESTORED AS SOON
AS POSSIBLE.
TEMPORARY BOILER
CONTROL ROOM AND
TRAILERS (SEE MC101)
CONCRETE JERSEY
BARRIERS (TYP.)
NEW TEMPORARY CONSTRUCTION FENCING.
FINAL FENCING AND GATE LOCATIONS TO BE
DETERMINED BY CONTRACTOR.
TEMPORARY ELECTRICAL
EQUIPMENT LOCATION (SEE EJ101)
o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t 4 o n e q u a rt e r in ch o n e f o o t
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Ser v ic e
D i s ab l e d Vet er an Owned Sma ll Business
SDVOSB
CVE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANT
Project Director
MR PROJECT NO: 0506-0011
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246 10
100% CORRECTED
CONSTRUCTION DOCUMENTS
01-07-2022
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD., STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502) 836-4232
LI CENSED PROFESSIONA
L
EN
GI
NE
ER
STA
TE O
F NEW YORK
0 9 4 6 7 4
C002
1 STAGING PLAN
SCALE: 1" = 10'
N
CIVIL
STAGING PLAN
C002
LMRRJS
0' 10' 20' 30'
STAGING PHASING SEQUENCE:
1. ERECT TEMPORARY CONSTRUCTION FENCING AND INITIAL EROSION CONTROL
MEASURES.
2. INSTALL SHEET PILE WALL
3. INSTALL 30,000 GALLON USTs
4. INSTALL ALL OTHER UTILITIES, BUILDING FOUNDATION, BUILDING, ETC.
LIMIT OF
DISTURBANCE (TYP.)
LIMIT OF DISTURBANCE (TYP.)
RD
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X X X X X X X X X X X
X
X
X X X X X X X X X X X X X X X
X X
X X X X X X X X
X X
X X
X X
X X
X X
X X
X X
X
X X
X X
X X
X X
X X
X X X X X X X
X X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X X
X X
XXXX
X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
XXXXXX
X
X
X
X
X
X
X
XXXXXXX
REMOVE AND DISPOSE
OF FULL DEPTH ASPHALT
PAVEMENT SECTION
LIMITS OF TREE
CLEARING
REMOVE AND DISPOSE
OF FENCE, POSTS, AND
POST FOUNDATIONS
FULL DEPTH SAWCUT
AT LIMITS OF REMOVAL
REMOVE AND DISPOSE
OF VEGETATION
PROTECT
UNDERGROUND
UTILITIES
REMOVE AND DISPOSE
OF CATCH BASIN
PROTECT
CONCRETE
RETAINING WALL
REMOVE AND DISPOSE OF WOOD
SHED AND FOUNDATION (REFER
TO NOTE 18 ON MC101)
REMOVE AND DISPOSE
OF FOUNDATION WALL
IN ITS ENTIRETY
REMOVE AND DISPOSE OF
EXISTING FENCE, FENCE
POSTS, GATES, AND
FOUNDATIONS
REMOVE AND DISPOSE OF
WATER LINE TO LIMITS
SHOWN ON UTILITY PLAN
REMOVE AND DISPOSE OF
SANITARY SEWER TO LIMITS
SHOWN ON UTILITY PLAN
REMOVE AND DISPOSE OF
SANITARY CLEANOUT
REMOVE AND DISPOSE AC
UNIT AND CONCRETE PAD
REMOVE AND DISPOSE OF
RAILROAD TIE RETAINING WALL.
PROTECT BUILDING WALL TO
REMAIN DURING REMOVAL.
REMOVE AND DISPOSE OF
CONCRETE RAMP SECTION
REMOVE AND DISPOSE OF
SANITARY MANHOLE
REMOVE AND DISPOSE OF
CONCRETE SIDEWALK SECTION
REMOVE AND DISPOSE OF
GUARD RAIL, POSTS, AND
POST FOUNDATIONS
REMOVE AND
DISPOSE OF
BOLLARDS
REMOVE AND DISPOSE
OF BOLLARDS
REMOVE AND DISPOSE OF
BUILDING, FOUNDATIONS,
SLAB, AND STEEL WATER TANK
REMOVE AND DISPOSE
OF STORM PIPE; PLUG
CONNECTION
REMOVE UNDERGROUND FUEL OIL
TANK AND REINFORCED CONCRETE
PAD - SEE UST NOTES
REMOVE UNDERGROUND FUEL OIL
TANK AND REINFORCED CONCRETE
PAD - SEE UST NOTES
REMOVE AND DISPOSE OF GAS
SERVICE TO BUILDING 11 -
COORDINATE WITH GAS UTILITY
REMOVE AND DISPOSE
OF WATER LINE
REMOVE AND DISPOSE OF
CONCRETE PAD SECTION
REMOVE AND DISPOSE
OF FULL DEPTH ASPHALT
PAVEMENT SECTION
REMOVE AND DISPOSE OF
WATER LATERAL
REMOVE AND DISPOSE OF SEWER
PIPE AND PLUG CONNECTION
DISCONNECT WIRING AND
REMOVE AND DISPOSE OF
ELECTRICAL CONDUIT
SEE DRAWING ES100 FOR
REMOVAL OF ELECTRICAL
FULL DEPTH SAWCUT
AT LIMITS OF REMOVAL
CONTRACTOR TO CONFIRM GAS LINE HAS
BEEN ABANDONED WITH OWNER PRIOR
TO ANY DEMOLITION WORK AND REMOVE
AND DISPOSE OF ABANDONED LINE
FULL DEPTH SAWCUT
AT LIMITS OF REMOVAL
FULL DEPTH SAWCUT
AT LIMITS OF REMOVAL
REMOVE AND DISPOSE
OF FULL DEPTH ASPHALT
PAVEMENT SECTION
REMOVE AND DISPOSE OF FULL DEPTH
ASPHALT PAVEMENT SECTION WITH 6"
THICK REINFORCED SUBSURFACE
CONCRETE SLAB
PROTECT EXISTING GAS
PIPING AND METERS
REMOVE AND DISPOSE OF FULL DEPTH
ASPHALT PAVEMENT SECTION WITH 6"
THICK REINFORCED SUBSURFACE
CONCRETE SLAB
REMOVE AND DISPOSE OF FULL DEPTH
ASPHALT PAVEMENT SECTION (NO
SUBSURFACE CONCRETE SLAB)
LIMITS OF REMOVAL
LIMITS OF REMOVAL
SEE DRAWING ES100
FOR REMOVAL OF
EXISTING
TRANSFORMER
SEE DRAWING ES100 FOR
REMOVAL OF ELECTRICAL
FULL DEPTH SAWCUT AT
NEAREST CONTROL JOINT
REMOVE AND DISPOSE OF
CONCRETE PAD SECTION
REMOVE AND DISPOSE OF CURB
SEE DRAWING ES100 FOR
REMOVAL OF ELECTRICAL
o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t 4 o n e q u a rt e r in ch o n e f o o t
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Ser v ic e
D i s ab l e d Vet er an Owned Sma ll Business
SDVOSB
CVE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANT
Project Director
MR PROJECT NO: 0506-0011
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246 10
100% CORRECTED
CONSTRUCTION DOCUMENTS
01-07-2022
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD., STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502) 836-4232
LI CENSED PROFESSIONA
L
EN
GI
NE
ER
STA
TE O
F NEW YORK
0 9 4 6 7 4
C101
1 EXISTING CONDITIONS AND DEMOLITION PLAN
SCALE: 1" = 10'
N
CIVIL
EXISTING CONDITIONS AND
DEMOLITION PLAN
C101
LMRRJS
0' 10' 20' 30'
UST REMOVAL NOTES:
1. CONTRACTOR SHALL CONDUCT ALL TANK REMOVAL IN ACCORDANCE WITH
APPLICABLE REGULATIONS INCLUDING 250-RICR-140-25-1.
2. CONTRACTOR SHALL COMPLETE ANY REQUIRED NOTIFICATIONS, INCLUDING RIDEM,
NBC, AND LOCAL FIRE SAFETY OFFICIAL
3. CONTRACTOR SHALL COMPLETE ALL WORK IN ACCORDANCE WITH AMERICAN
PETROLEUM INSTITUTE (API) RECOMMENDED PRACTICE (RP) PUBLICATION 2015 “SAFE
ENTRY AND CLEANING OF PETROLEUM STORAGE TANKS, 7TH EDITION" (2014) AND
AMERICAN PETROLEUM INSTITUTE (API) RECOMMENDED PRACTICE (RP) PUBLICATION
1604 “CLOSURE OF UNDERGROUND PETROLEUM STORAGE TANKS, 3RD EDITION"
(1996).
4. CONTRACTOR SHALL COMPLETE, PROVIDE TO THE OWNER FOR APPROVAL AND THEN
SUBMIT THE PRODUCT PIPELINE PERMANENT CLOSURE APPLICATION FORM TO THE
RHODE ISLAND DEM AT LEAST 10 DAYS IN ADVANCE OF THE WORK.
5. CONTRACTOR SHALL COMPLETE THE REMOVAL, CHARACTERIZATION/PROFILING AND
DISPOSAL OF ALL PRODUCT FROM THE USTS AND ASSOCIATED PIPING.
6. CONTRACTOR SHALL APPROPRIATELY VENT AND TEST THE INTERIOR ATMOSPHERE OF
THE TANK PRIOR TO ENTERING OR CUTTING THE TANK.
7. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL RESIDUALS WITHIN THE TANK AND
ASSOCIATED PIPING.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FEES ASSOCIATED WITH THE CLOSURE
OF THE USTS.
9. CONTRACTOR SHALL ALLOW FOR AND ASSIST RI DEM PERSONNEL, LOCAL SAFETY
OFFICIALS AND THE ENVIRONMENTAL CONSULTANT WITH ACCESSING THE WORK AREA
AS REQUESTED DURING THE WORK TO ALLOW FOR INSPECTION.
10. CONTRACTOR SHALL ASSIST WITH AND FOLLOW THE DIRECTION OF THE
ENVIRONMENTAL CONSULTANT (PROVIDED BY OWNER) FOR COMPLETING ANY
REQUESTED ACCESS, OBSERVATIONS AND SAMPLING OF SOIL OR OTHER MATERIAL.
11. CONTRACTOR SHALL REMOVE, CHARACTERIZE AND DISPOSE OF IMPACTED SOIL AND
WATER (GROUNDWATER, RAINWATER OR PERCHED WATER) AS REQUESTED BY THE
ENVIRONMENTAL CONSULTANT.
12. CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR THE DISPOSAL AND/OR
RECYCLING OF THE UST/PIPING CONTENTS, UST/PIPING MATERIALS, AND ANY
ASSOCIATED IMPACTED SOIL AND GROUNDWATER TO THE OWNER AND
ENVIRONMENTAL CONSULTANT WITHIN 48 HRS OF RECEIVING DOCUMENTATION.
WEIGH TICKETS, MANIFESTS AND DISPOSAL RECEIPTS ARE REQUIRED.
±1 ,10
0 S F
BU
ILD
IN
G
AD
DI
TI
ON
6.
A B C D
E
BB B.
C C
D D
39'
43'
58'
0.5'
7'
4' O.
C.
(T
YP
5' (TYP.)
7'
5'4' O.
C.
5'
±500 SF
BUILDING
ADDITION
4.5'
43.64'
8.
.5'
7.
43°
7°
33.83'
3'
4.5
R5'
.7
8.
5'
N: 272248.4519 E: 346568.3734
NEW 6' HIGH BLACK VINYL
COATED CHAIN LINK FENCE
NEW ASPHALT PAVEMENT
PROPOSED
TREE LINE
PAVEMENT JOINT
NEW SHEET PILE
RETAINING WALL
PROPOSED BUILDING
FOOTER (TYP.)
NEW OVERHEAD DOOR
NEW METAL STAIRS
(SEE DRAWING
AE501 AND AE507)
NEW AC UNIT UNDER STAIRS
(SEE DRAWING MC101)
NEW CONCRETE
SIDEWALK
RESTORE ALL DISTURBED
AREAS TO LAWN
NEW GUARD
RAIL
NEW GUARD RAIL
NEW 6' HIGH BLACK VINYL COATED
CHAIN LINK FENCE (ALTERNATE 1)
NEW 16' WIDE BLACK VINYL COATED
SLIDE GATE (ALTERNATE 1)
TEMPORARY SHORING WALL
- DELEGATED DESIGN
NEW ASPHALT PAVEMENT
NEW STANDARD DUTY
ASPHALT PAVEMENT
PAVEMENT JOINT
NEW 6' HIGH BLACK VINYL COATED
CHAIN LINK FENCE (ALTERNATE 1)
NEW STANDARD BOLLARD
NEW 30,000 GALLON UST
(SEE DRAWING MC101)
NEW 4,000 GALLON UST
(SEE DRAWING MC101)
BOTTOM ELEV = 62.00
NEW WATER TANK STRUCTURAL SLAB
(SEE DRAWING S560)
NEW CONCRETE PAD (SEE
CONCRETE PAD DETAIL 14/C501)
M-30 SECURITY
BOLLARD (TYP.)
BASE-BID: NEW BLAST WALL
(SEE DRAWING S560)
ALTERNATE: NEW 6' HIGH
FENCE WITH ANTI-RAM CABLE
NEW STANDARD BOLLARD
NEW ASPHALT PAVEMENT
PAVEMENT JOINT
NEW ASPHALT PAVEMENT
SECTION WITH 6" THICK
REINFORCED SUBSURFACE
CONCRETE SLAB. CONTRACTOR
SHALL REVIEW EXISTING
PAVEMENT SECTION AND REPORT
TO ENGINEER. NEW PAVEMENT
SECTION SHALL MATCH OR
EXCEED EXISTING PAVEMENT
SECTION.
PAVEMENT JOINT
PAVEMENT JOINT
NEW CONCRETE
BOLLARD
FOUNDATION
NEW WATER TANK (SEE
DRAWING PS100)
NEW CONCRETE
SIDEWALK
STORMWATER
DETENTION
(SEE C301
UTILITY PLAN)
NEW 16' WIDE BLACK
VINYL COATED SLIDE
GATE (ALTERNATE 1)
NEW GRANITE CURB
NEW 8' X 8' CONCRETE PAD AROUND
TANK MANHOLE COVERS (SEE
CONCRETE PAD DETAIL 14/C501)
TEMPORARY SHORING WALL
- DELEGATED DESIGN
TEMPORARY SHORING WALL
- DELEGATED DESIGN
NEW INTERCOM
(SEE TY002)
NEW ASPHALT PAVEMENT SECTION WITH 6" THICK
REINFORCED SUBSURFACE CONCRETE SLAB.
CONTRACTOR SHALL REVIEW EXISTING PAVEMENT
SECTION AND REPORT TO ENGINEER. NEW
PAVEMENT SECTION SHALL MATCH OR EXCEED
EXISTING PAVEMENT SECTION.
NEW ASPHALT PAVEMENT SECTION
(NO SUBSURFACE CONCRETE SLAB)
4'
5'
NEW CHAIN LINK FENCE WITH LOCKABLE 3' WIDE
MAN GATE- COORDINATE HEIGHT WITH METAL
ROOF (SEE ARCHITECTURAL DRAWINGS)
NEW CONCRETE PAD
AND LPG CYLINDERS
(SEE DRAWING MC101)
NEW 6' HIGH BLACK VINYL COATED
CHAIN LINK FENCE (ALTERNATE 1)
NEW INTERCOM
(SEE TY002)
13.08'
.2
7'
5.
18.24'
LIMIT OF
DISTURBANCE (TYP.)
LIMIT OF DISTURBANCE (TYP.)
RD
SA CO
HH
HH
E
E
SA CO
ST-CB-P1
ST-MH-P3
ST-MH-P2
o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t 4 o n e q u a rt e r in ch o n e f o o t
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Ser v ic e
D i s ab l e d Vet er an Owned Sma ll Business
SDVOSB
CVE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANT
Project Director
MR PROJECT NO: 0506-0011
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246 10
100% CORRECTED
CONSTRUCTION DOCUMENTS
01-07-2022
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD., STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502) 836-4232
LI CENSED PROFESSIONA
L
EN
GI
NE
ER
STA
TE O
F NEW YORK
0 9 4 6 7 4
C201
1 SITE PLAN
SCALE: 1" = 10'
N
CIVIL
SITE PLAN
C201
LMRRJS
IMPERVIOUS QUANTITIES
PROPOSED IMPERVIOUS DIFFERENCE
± 9,700 SF ± 13,350 SF ± 3,650 SF
EXISTING IMPERVIOUS
0' 10' 20' 30'
6.
A B C D
E
BB B.
C C
D D
NEW 30,000 GALLON UST
(SEE DRAWING MC101)
NEW 4,000 GALLON UST
(SEE DRAWING MC101)
BOTTOM ELEV = 62.00
BASE-BID: NEW BLAST WALL
(SEE DRAWING S560)
ALTERNATE: NEW 6' HIGH
FENCE WITH ANTI-RAM CABLE
NEW WATER TANK (SEE
DRAWING PS100)
LIMIT OF
DISTURBANCE (TYP.)
LIMIT OF DISTURBANCE (TYP.)
RD
NEW 8" GATE VALVE
NEW 8" GATE VALVE
W W W W W W W
W
W
W W W W W
W
W W
W W
W W
W W
W W
W W
W
W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W
W
W
W
W
WW
SA CO
NEW 22.5° ELBOW
NEW 45° ELBOW
NEW 45°
ELBOW
NEW 6"
CLEANOUT
NEW 6" CLEANOUT
MAINTAIN 18" MINIMUM VERTICAL
SEPARATION BETWEEN WATER
AND SEWER LINES
NEW SAMPLING /
DISINFECTION TAP
NEW SAMPLING /
DISINFECTION TAP
ST
NEW CULTEC 330-RXLHD
STORMCHAMBERS (1 ROW OF 3
CHAMBERS, 1 ROW OF 10 CHAMBERS)
BOTTOM OF CHAMBER ELEVATION = 63.98
BOTTOM OF STONE ELEVATION = 63.48
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FUEL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FUEL
FUEL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FUEL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FUELFUEL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FUELFUEL
FU
EL
FUEL
FU
EL
FUEL
FUEL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FUELFUEL
FUEL
UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UEUEUEUEUEUEUEUE
NEW ELECTRICAL
LINE (TYP., SEE
DRAWING ES101)
NEW ELECTRICAL MANHOLE
(SEE DRAWING ES101)
NEW ELECTRICAL
LINE (TYP., SEE
DRAWING ES101)
NEW 8" DIP
WATER SERVICE
NEW ELECTRICAL LINE (TYP.,
SEE DRAWING ES101)
NEW 2" FUEL LINE (TYP.,
SEE DRAWING MS100)
W W W W W W
W
W
W
W W W W W W
W
W
W W
NEW 45° ELBOW
NEW 4" DIP
WATER SERVICE
NEW 6" DIP WATER
FIRE SERVICE
SA
W
NEW 45°
ELBOW
NEW 4" DIP
WATER SERVICE
6" PVC SDR-35
SANITARY SEWER
@ 1.00% MIN.
GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGG
G
G
G
G
G
G
G
G
G G
G G
G G
G G
G G
G G
G G
G G
G G
G G
G G
G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G
G G
G G
NEW 90° BEND
NEW 4" GAS SERVICE TO TEMPORARY
BOILERS. SEE MC101 FOR
TEMPORARY BOILER LOCATION AND
CONNECTION POINT
NEW 4" GATE VALVE
HH
UE UE UE UE UE UE
UE
UE
UE
UE
UE
UE
UEUEUEUE
HH UE UE UE
UEUEUEUEUEUEUEUEUE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
NEW ELECTRICAL LINE
(TYP., SEE DRAWING
ES101)
NEW ELECTRICAL
HANDHOLE (TYP., SEE
DRAWING ES101)
UE
NEW 45°
ELBOW
NEW 4" GAS SERVICE TO
TEMPORARY BOILERS
E
E
NEW HOT BOX (SEE
DRAWING PS100)
NEW ELECTRICAL
LINE (TYP., SEE
DRAWING ES101)
PROVIDE MIN. 18" VERTICAL
SEPARATION BETWEEN
WATER AND SEWER (TYP.
OF ALL CROSSINGS)
NEW 4" GAS SERVICE TO
TEMPORARY BOILERS
INSPECTION PORT
W
ST
ST
ST-S
A
ST-S
A
ST-S
A
ST-S
A
ST
-S
A
ST
-S A
ST
-S
A
ST
-S A
ST
-S
A
ST
-S A
SA SA SA SA
SA SA SA SA
SA CO
NEW 6" CLEANOUT
ST-CB-P1
ST-MH-P3
ST
ST
INSPECTION PORT
FU
EL
FU
EL
FUELFUELFUELFUELFUELFUELFUELFUELFUELFUELFUELFUEL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FU
EL
FUELFUELFUELFUELFUELFUELFUELFUELFUELFUELFUELFUEL
FUEL RE-FILL LINES
(SEE DRAWING MC101)
ST-MH-P2
NEW ELECTRICAL MANHOLE
(SEE DRAWING ES101)
COMM
COMM
COMM
COMM
COMM COMM COMM
NEW SECURITY
ELECTRICAL LINE (TYP.,
SEE DRAWING TY002)
US
T
0+
US
T
0+
10'
MIN.
SEPARATION
9' 10' MIN. SEPARATION 5' 6.67'
NEW ELECTRICAL LINE
(TYP., SEE DRAWING
ES101)
UE UE
UEUEUEUEUEUE
CO
M
M
CO
M M
CO
M
M
CO
M M
CO
M
M
CO
M M
CO
M
M
CO
M M
CO
M
M
CO
M M
CO
M
M
CO
M M
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
ST-MH-P3
RIM=68.58
WEIR TOP=65.10
N INV=64.24
SW INV=64.34
SE INV=64.45
6" SICPP @ 0.50%
ST-CB-P1
RIM=67.28
SE INV=64.78
12" SICPP @ 0.50%
8" PVC SDR-35 COMBINED SEWER @
1.00%
6" PVC SDR-35
SANITARY SEWER @ 2.00% MIN.
4" PVC SDR-26
SANITARY SEWER @ 2.00% MIN.
8" P
VC
S
DR
-2
CO
M
BI
NE
D
SE
W
ER
.0
0% M
IN
ST
ST
24" SICPP @ 0.00%24" SICPP @ 0.00%
ST-MH-P2
RIM=67.56
WEIR TOP=66.75
SW INV=64.75
SE INV=64.75
NW INV=64.75
NEW SECURITY
ELECTRICAL LINE (TYP.,
SEE DRAWING TY002)
SEE 2/C301 FOR UST
CROSS-SECTION
PROVIDE SERIES TF-1 TIDEFLEX
CHECK VALVE (OR APPROVED EQUAL)
AT PIPE CONNECTION TO MANHOLE
NEW 8" DIP
WATER SERVICE
NEW 8" DIP
WATER SERVICE
0+00 0+10 0+20 0+30 0+40 0+50
Ø1 2'
Ø1 2'
3'
7.6 4'
3'
1' 1' 6.1
5'
1' 1'
12' DIA. 30,000 GAL TANK
MINIMUM COVER ELEV
EXISTING GRADE
PROPOSED GRADE
BEDDING MATERIAL
ANTI-BUOYANCY
CONCRETE BALLAST PAD TANK BACKFILL MATERIAL
BUILDING BACKFILL MATERIAL
PR
OP
OS
ED
B
UI
LD
IN
G
3'
TEMPORARY SHORING WALL -
DELEGATED DESIGN TEMPORARY SHORING
WALL - DELEGATED DESIGN
o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t 4 o n e q u a rt e r in ch o n e f o o t
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Ser v ic e
D i s ab l e d Vet er an Owned Sma ll Business
SDVOSB
CVE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANT
Project Director
MR PROJECT NO: 0506-0011
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246 10
100% CORRECTED
CONSTRUCTION DOCUMENTS
01-07-2022
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD., STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502) 836-4232
LI CENSED PROFESSIONA
L
EN
GI
NE
ER
STA
TE O
F NEW YORK
0 9 4 6 7 4
C301
1 UTILITY PLAN
SCALE: 1" = 10'
N
CIVIL
UTILITY PLAN
C301
LMRRJS
0' 10' 20' 30'
WATER MAIN INSTALLATION SEQUENCE:
1. INSTALL PROPOSED WATER MAIN IN ITS ENTIRETY TO VALVES ADJACENT TO
EXISTING WATER MAIN
2. PRESSURE TEST NEW WATER MAIN INSTALLATION
3. DISINFECT AND SAMPLE PROPOSED WATER MAIN
4. COORDINATE WITH VAMC TO SHUT DOWN WATER SERVICE TO BE DEMOLISHED
5. CUT EXISTING WATER MAIN AND CONNECT TO NEW VALVES
6. REMOVE AND DISPOSE OF EXISTING WATER THAT HAS BEEN DISCONNECTED
NOTES:
1. SICPP = SMOOTH INTERIOR CORRUGATED POLYETHYLENE PIPE
C301
2 30,000 GAL TANK ELEVATION VIEW
HORIZONTAL SCALE: 1" = 10'
VERTICAL SCALE: 1" = 10'
6.
A B C D
E
BB B.
C C
D D
NEW 30,000 GALLON UST
(SEE DRAWING MC101)
NEW 4,000 GALLON UST
(SEE DRAWING MC101)
BOTTOM ELEV = 62.00
BASE-BID: NEW BLAST WALL
(SEE DRAWING S560)
ALTERNATE: NEW 6' HIGH
FENCE WITH ANTI-RAM CABLE
NEW WATER TANK (SEE
DRAWING PS100)
LIMIT OF
DISTURBANCE (TYP.)
LIMIT OF DISTURBANCE (TYP.)
RD
±1 ,10
0 S F
BU
ILD
IN
G
AD
DI
TI
ON
FF
E
.00
67.65
68.40
71.58
72.00
68.37
67.91
72.50
72.00
72.18
7 0
7 2
52 51
75.31
68.55
71.41
67.87
79 78 77 76 75
RETAINING WALL (SEE C402
RETAINING WALL DETAILS)
NEW METAL STAIRS
(SEE DRAWING AE102)
MATCH TO
EXISTING GRADE
MAX 2% CROSS-SLOPE
STORMWATER DETENTION
(SEE C301 UTILITY PLAN)
MAX 5% SLOPE
67.73
FFE = 68.50
BU
RY
S
EC
TI
ON
O F
SH
EE
T
PI
LE
S
3' M
IN
IM
UM
B
EL
OW
G
RA
DE
68.2768.50
4 ON 1 SLOPE
2 ON 1 SLOPE
2 ON 1 SLOPE
67.83
67.96
67.83
SLAB ELEV
= 68.00
67.43
67.96 BC
68.46 TC
68.02
67.71
67.73
67.17 BC
67.67 TC
67.40
66.88 BC
67.38 TC
INSTALL AND MAINTAIN
SILT SOCK INLET
PROTECTION (TYP.)
INSTALL AND MAINTAIN
COMPOST FILTER SOCK
EROSION CONTROL (TYP.)
INSTALL AND MAINTAIN
CONSTRUCTION
ENTRANCE
INSTALL AND MAINTAIN
COMPOST FILTER SOCK
EROSION CONTROL (TYP.)
PROVIDE EROSION
CONTROL BLANKET
ON ALL DISTURBED
PORTIONS OF HILL
PROVIDE EROSION
CONTROL BLANKET
ON ALL DISTURBED
PORTIONS OF HILL
PROVIDE EROSION CONTROL
BLANKET ON ALL PROPOSED
SLOPES GREATER THAN 15%
INSTALL AND MAINTAIN
CONCRETE WASHOUT
INSTALL AND MAINTAIN
SILT SOCK INLET
PROTECTION (TYP.)
INSTALL AND MAINTAIN
CONSTRUCTION
ENTRANCE
71.90
71.64
80 80
79 78
75 74 73
FFE = 72.00
72.50
72.4672.46
72.50
SA CO
HH
HH
E
E
SA CO
ST-CB-P1
ST-MH-P3
ST-MH-P2
ST-MH-P3
RIM=68.58
ST-CB-P1
RIM=67.28
o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t 4 o n e q u a rt e r in ch o n e f o o t
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Ser v ic e
D i s ab l e d Vet er an Owned Sma ll Business
SDVOSB
CVE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANT
Project Director
MR PROJECT NO: 0506-0011
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246 10
100% CORRECTED
CONSTRUCTION DOCUMENTS
01-07-2022
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD., STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502) 836-4232
LI CENSED PROFESSIONA
L
EN
GI
NE
ER
STA
TE O
F NEW YORK
0 9 4 6 7 4
C401
1 GRADING AND EROSION CONTROL PLAN
SCALE: 1" = 10'
N
CIVIL
GRADING AND
EROSION CONTROL PLAN
C401
LMRRJS
NOTES:
1. CONTRACTOR SHALL COORDINATE WITH THE COR FOR EXCESS SOIL STOCKPILE LOCATIONS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY PROTECTION OF ADJACENT
UTILITIES, STRUCTURES, AND BUILDINGS NECESSARY FOR INSTALLATION OF THE
PROPOSED FUEL TANKS.
3. CONTRACTOR SHALL SHALL BE RESPONSIBLE FOR CLEANING AND SWEEPING PAVEMENT ON
AIR FORCE DRIVE TO ENSURE ROAD REMAINS CLEAN AND FREE OF CONSTRUCTION DEBRIS.
6.
A B C D
E
BB B.
C C
D D
3'
4.5
5'
3.5'
LIMIT OF
DISTURBANCE (TYP.)
LIMIT OF DISTURBANCE (TYP.)
7 0
7 2
52 51
BU
RY
S
EC
TI
ON
O F
SH
EE
T
PI
LE
S
3' M
IN
IM
UM
B
EL
OW
G
RA
DE
SA CO
HH
E
E
SA CO
US
T
0+
US
T
0+
7' O.
C.
(T
YP
A-A' 0+00 A-A' 1+00 A-A' 1+62
B 0+24 B 1+00
B 1+72
C-C' 0+00 C-C' 1+00 C-C' 1+45
D- D'
D- D'
D-
D'
FREE / UNBONDED
SOIL ANCHOR (TYP.)
FIXED / BONDED
SOIL ANCHOR (TYP.)
SHEET PILE
RETAINING WALL
NEW 30,000 GALLON
UST (SEE MECHANICAL
PLANS FOR DETAILS)
NEW 30,000 GALLON
UST (SEE MECHANICAL
PLANS FOR DETAILS)
CAP SHEET PILE WALL
WITH FABRICATED
STEEL CAP (TYP.)
Profile View of A-A'
-29
-20
-10
-29.00
-20.00
-10.00
0.00
10.00
20.00
30.00
40.00
50.00
60.00
70.00
80.00
0+00 0+50 1+00 1+50 1+80
GLACIAL OUTWASH-2
medium to fine SAND, trace Silt Navg = 14, f = 31°, g = 115 pcf
GLACIAL OUTWASH-3
coarse to fine SAND, little coarse to fine Gravel, little Silt
Navg = 24, f = 34°, g = 130 pcf
GLACIAL OUTWASH-1
Coarse to fine SAND, little coarse to fine Gravel, trace Silt
Navg = 13, f = 31°, g = 115 pcf
FILL
(coarse to fine SAND, little Silt, trace fine Gravel)
EXISTING BOILER HOUSE
BUILDING 10
PROPOSED
BUILDING ADDITION
30°'
EXISTING
RAILROAD TIE
KNEE-WALL
WHALER CONSISTS OF 2 -
GRADE A-50 C 12 X 30 CHANNELS
BACK TO BACK W/SHIM PLATE
GRADE A-50
PZ35 SHEET PILE
TOP OF SHEET PILE @ 3'-0" MIN.
ABOVE PARKING LOT GRADE
FREE / UNBONDED SOIL
ANCHOR LENGTH = 84.5'
FIXED / BONDED SOIL ANCHOR
LENGTH = 25', DIAMETER = 12"
EXISTING GRADE
PROPOSED GRADE
ASPHALT SECTION
(SEE DETAIL)
SOIL ANCHOR CONSISTS OF:
47-mm DIAMETER DYWIDAG
Y1050H THREAD BAR
100' MIN. LONG, GRADE
A-50 PZ35 SHEET PILE
WATER TABLE
250 PSF600 PSF
7,000 PSF
8.5' MIN.
22' SHEET PILE
EMBEDMENT
BELOW LOWEST
SEISMIC FAILURE
CIRCLE
EXISTING 4' HIGH
CHAIN LINK FENCE
EXISTING 4' HIGH
CHAIN LINK FENCE
NEW GUIDE RAIL
NOTE: FLOOR SLAB AND
FOUNDATIONS SHOWN FOR
ILLUSTRATIVE PURPOSES ONLY
4,000 PSF4,000 PSF
FAILURE WEDGE UNDER
SEISMIC CONDITIONS
3,500 PSF
7,500 PSF10,750 PSF
Profile View of B
-31 -30
-20
-10
-31.00 -30.00
-20.00
-10.00
0.00
10.00
20.00
30.00
40.00
50.00
60.00
70.00
80.00
0+00 0+50 1+00 1+50 1+80
GLACIAL OUTWASH-2
medium to fine SAND, trace Silt Navg = 14, f = 31°, g = 115 pcf
GLACIAL OUTWASH-3
coarse to fine SAND, little coarse to fine Gravel, little Silt
Navg = 24, f = 34°, g = 130 pcf
GLACIAL OUTWASH-1
Coarse to fine SAND, little coarse to fine Gravel, trace Silt
Navg = 13, f = 31°, g = 115 pcf
FILL
(coarse to fine SAND, little Silt, trace fine Gravel)
Navg = 8, f = 30°, g = 110 pcf
EXISTING BOILER HOUSE
BUILDING 10
NOTE: FLOOR SLAB AND
FOUNDATIONS SHOWN FOR
ILLUSTRATIVE PURPOSES ONLY
30°'
EXISTING
RAILROAD TIE
KNEE-WALL
WHALER CONSISTS OF 2 -
GRADE A-50 C 12 X 30 CHANNELS
BACK TO BACK W/SHIM PLATE
GRADE A-50
PZ35 SHEET PILE
TOP OF SHEET PILE @ 3'-0" MIN.
ABOVE PARKING LOT GRADE
FREE / UNBONDED SOIL
ANCHOR LENGTH = 75'
FIXED / BONDED SOIL ANCHOR
LENGTH = 20', DIAMETER = 12"
EXISTING GRADE
PROPOSED GRADE
ASPHALT SECTION
(SEE DETAIL)
SOIL ANCHOR CONSISTS OF:
36-mm DIAMETER DYWIDAG
Y1050H THREAD BAR
100' MIN. LONG, GRADE
A-50 PZ35 SHEET PILE
WATER TABLE
250 PSF
400 PSF
3,500 PSF7,500 PSF
22' SHEET PILE
EMBEDMENT
BELOW LOWEST
SEISMIC FAILURE
CIRCLE
EXISTING 4' HIGH
CHAIN LINK FENCE
EXISTING 4' HIGH
CHAIN LINK FENCE
NEW GUIDE RAIL
FAILURE WEDGE UNDER
SEISMIC CONDITIONS
4,000 PSF
o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t 4 o n e q u a rt e r in ch o n e f o o t
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
A Ser v ic e
D i s ab l e d Vet er an Owned Sma ll Business
SDVOSB
CVE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANT
Project Director
MR PROJECT NO: 0506-0011
REPLACE BOILERS IN BUILDING 10
830 CHALKSTONE AVENUE
PROVIDENCE, RI 02908
650-19-100
HAZARDOUS MATERIALS
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, STONEHAM, MA 02180
PHONE: (781)275-6050
CIVIL / STRUCTURAL
LABELLA
303 SOUTH STREET, SUITE 201, ROCHESTER, NY 14614
PHONE: (585)454-6110
ARCHITECTURAL
OCULUS INC.
1 SOUTH MEMORIAL DRIVE, SUITE 1500, SAINT LOUIS, MO 63102
PHONE: (314)367-6100
ELECTRONIC SECURITY
GRW
801 CORPORATE DRIVE, LEXINGTON, KY 40503
PHONE: (859)223-3999
FIRE SUPPRESSION
KOFFEL ASSOCIATES
8815 CENTRE PARK DRIVE, SUITE 200, COLUMBIA, MD 21045
PHONE: (410)750-2246 10
100% CORRECTED
CONSTRUCTION DOCUMENTS
01-07-2022
PHYSICAL SECURITY
FORCE PROTECT SECURITY CONSULTANTS
10901 FRONT BEACH RD., STE 1415, PANAMA CITY BEACH, FL 32407
PHONE: (502) 836-4232
LI CENSED PROFESSIONA
L
EN
GI
NE
ER
STA
TE O
F NEW YORK
0 9 4 6 7 4
C401
1 RETAINING WALL AND SOIL ANCHOR PLAN VIEW
SCALE: 1" = 10'
N
RETAINING WALL NOTES:
1. THIS CROSS-SECTION WAS DEVELOPED BY SCALING THE DISTANCE FROM THE BOILER BUILDING (BUILDING 10) TO THE PROVIDED CONTOUR LINES
2. THE GEOTECHNICAL PROPERTIES PROVIDED ARE BASED ON THE INFORMATION PRESENTED ON THE BORINGS LOGS PROVIDED IN APPENDIX B OF THE REPORT TITLED:
SHEET PILE RETAINING WALL SYSTEM CALCULATIONS AND REPORT AND FROM THE COMPUTER PROGRAM TITLED: SHORING SUITE BY CIVILTECH SOFTWARE, INC.
C402
2 RETAINING WALL CROSS-SECTION A-A'
HORIZONTAL SCALE: 1" = 10'
VERTICAL SCALE: 1" = 10'
CIVIL
RETAINING WALL DETAILS
C402
LMRRJS
C402
3 RETAINING WALL CROSS-SECTION B-B'
HORIZONTAL SCALE: 1" = 10'
6.
A B C D
E
BB B.
C C
D D
3'
4.5
5'
3.5'
LIMIT OF
DISTURBANCE (TYP.)
LIMIT OF DISTURBANCE (TYP.)
7 0
7 2
52 51
SA CO
HH
E
E
SA CO
US
T
0+
US
T
0+
7' O.
C.
(T
YP
A-A' 0+00 A-A' 1+00 A-A' 1+62
B 0+24 B 1+00
B 1+72
C-C' 0+00 C-C' 1+00 C-C' 1+45
D- D'
D- D'
D-
D'
FREE / UNBONDED
SOIL ANCHOR (TYP.)
FIXED / BONDED
SOIL ANCHOR (TYP.)
SHEET PILE
RETAINING WALL
NEW 30,000 GALLON
UST (SEE MECHANICAL
PLANS FOR DETAILS)
NEW 30,000 GALLON
UST (SEE MECHANICAL
PLANS FOR DETAILS)
CAP SHEET PILE WALL
WITH FABRICATED
STEEL CAP (TYP.)
Profile View of C-C'
-15
-10
-15.00
-10.00
0.00
10.00
20.00
30.00
40.00
50.00
60.00
70.00
80.00
0+00 0+50 1+00 1+50 1+80
GLACIAL OUTWASH-2
medium to fine SAND, trace Silt Navg = 14, f = 31°, g = 115 pcf
GLACIAL OUTWASH-3
coarse to fine SAND, little coarse to fine Gravel, little Silt
Navg = 24, f = 34°, g = 130 pcf
GLACIAL OUTWASH-1
Coarse to fine SAND, little coarse to fine Gravel, trace Silt
Navg = 13, f = 31°, g = 115 pcf
FILL
(coarse to fine SAND, little Silt, trace fine Gravel)
Navg = 8, f = 30°, g = 110 pcf
WHALER CONSISTS OF 2 -
GRADE A-50 C 12 X 30 CHANNELS
BACK TO BACK W/SHIM PLATE
GRADE A-50
PZ35 SHEET PILE
FREE / UNBONDED SOIL
ANCHOR LENGTH = 62'
FIXED / BONDED SOIL ANCHOR
LENGTH = 20', DIAMETER = 12"
EXISTING GRADE
PROPOSED GRADE
SOIL ANCHOR CONSISTS OF:
32-mm DIAMETER DYWIDAG
Y1050H THREAD BAR
85' LONG, GRADE A-50
PZ35 SHEET PILE
WATER TABLE
6' MIN.
22' SHEET PILE
EMBEDMENT
BELOW LOWEST
SEISMIC FAILURE
CIRCLE
EXISTING 4' HIGH
CHAIN LINK FENCE
EXISTING 4' HIGH
CHAIN LINK FENCE
FAILURE WEDGE UNDER
SEISMIC CONDITIONS
EXISTING
RAILROAD TIE
KNEE-WALL
NEW 30,000
GAL UST
30°'
Profile View of D-D'
-31 -30
-20
-10
-31.00 -30.00
-20.00
-10.00
0.00
10.00
20.00
30.00
40.00
50.00
60.00
70.00
80.00
0+00 0+50 1+00 1+50 1+60
GRADE A-50 PZ35
SHEET PILE (TYP.)
PROPOSED GRADE
EXISTING GRADE
7' (TYP.)
3'
3.5' 3.5'
3.5' 3' 3.5'
3.5'
3.5'
VEGETATED SURFACE ASPHALT PAVEMENT SURFACE
3.5'
3.5'
REFER TO CROSS-SECTIONS
FOR TIE BACK ROD DETAILS
WALER CONSISTS OF 2 - GRADE
A-50 C15 X 40 CHANNELS BACK
TO BACK W/SHIM PLATE
WALER CONSISTS OF 2 - GRADE
A-50 C15 X 40 CHANNELS BACK
TO BACK W/SHIM PLATE WALER CONSISTS OF 2 - GRADE
A-50 C15 X 40 CHANNELS BACK
TO BACK W/SHIM PLATE
7' (TYP.)
BURY SEGMENT OF SHEET
PILES 3' MINIMUM BELOW
GRADE. REFER TO C401
FOR GRADES
3.5'
WALER CONSISTS OF 2 - GRADE
A-50 C15 X 40 CHANNELS BACK
TO BACK W/SHIM PLATE
o n…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .