THIRD FLOOR PLAN
SCALE: 1/4" = 1'-0"
P-105 P-105 N THIRD FLOOR PLAN - DEMOLITION
SCALE: 1/4" = 1'-0"
P-105 P-105 N
GENERAL NOTES
G1. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS
SPECIFICALLY MARKED EXISTING, EXIST., OR (E).
G2. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND COORDINATE
ALL WORK PRIOR TO THE START OF CONSTRUCTION.
G3. COORDINATE PLUMBING PIPING LOCATION WITH ELECTRICAL PANELS AND
EQUIPMENT. PIPING SHALL NOT CROSS OVER PANELS. REFER TO
ELECTRICAL DRAWINGS.
G4. COORDINATE PLUMBING PIPING WITH MECHANICAL EQUIPMENT, PIPING
AND DUCTWORK. REFER TO MECHANICAL DRAWINGS.
G5. FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS AND FLOORS.
G6. PROVIDE ISOLATION VALVES IN ACCESSIBLE LOCATION.
NOTES
1. REMOVE FIXTURE, SUPPORTS, ASSOCIATED PIPING, VALVES AND
APPURTENANCES COMPLETE TO POINTS INDICATED AT WALLS AND FLOORS.
CAP HW PIPE IN WALL FOR FIXTURES WITH HW CONNECTIONS.
2. REMOVE FIXTURE, SUPPORTS, ASSOCIATED PIPING, VALVES AND
APPURTENANCES COMPLETE TO POINTS INDICATED.
3. REMOVE FIXTURE, SUPPORTS, ASSOCIATED PIPING, VALVES AND
APPURTENANCES COMPLETE TO POINTS INDICATED. CAP PIPES IN WALLS AND
BELOW FLOORS AS INDICATED.
4. REMOVE PIPING, VALVES, SUPPORTS AND APPURTENANCES COMPLETE TO
POINTS INDICATED.
5. PROVIDE 1/2" COLD WATER TAP IN CABINETRY BELOW SINK FOR
REFRIGERATOR. PROVIDE 1/2" SHUTOFF VALVE AND A WATTS SERIES LF7R
BACKFLOW PREVENTOR.
6. INDICATED PIPING IS LOCATED BELOW FLOOR SLAB.
7. INDICATED PIPING IS LOCATED ABOVE CEILING.
8. ROUTE DOMESTIC WATER AND WASTE AND VENT PIPING IN CHASE TO SERVE
PLUMBING FIXTURES. REUSE EXISTING FLOOR PENETRATION FOR WASTE PIPE
ON FLOOR MOUNTED FIXTURES.
9. CORE DRILL EXISTING FLOOR TO ALLOW FOR PIPING PENETRATION.
10. PATCH, REPAIR AND FINISH FLOOR TO MATCH EXISTING ADJACENT SURFACES
WHERE PENETRATIONS ARE NOT BEING USED. REFER TO DETAIL 1 ON P-002.
11. PATCH, REPAIR AND FINISH WALLS UPON COMPLETION OF WORK. SEE
ARCHITECTURAL DRAWINGS FOR DETAILS.
12. PROVIDE 1/2" COLD WATER LINE BELOW FLOOR SLAB FROM TRAP PRIMER TO
FLOOR DRAIN. INSTALL TPV ON EXISTING CW LINE TO WATER CLOSETS.
13. PROVIDE MINIMUM 18"x18" ACCESS DOOR IN WALL FOR ACCESS TO WATER
HAMMER ARRESTOR AND TRAP PRIMING VALVE. COORDINATE VALVES AND
ARRESTOR LOCATION WITH ACCESS DOOR.
14. REMOVE PORTIONS OF EXISTING WALLS ON 2ND AND 3RD FLOORS TO PERFORM
WORK AS INDICATED. PATCH, REPAIR AND FINISH WALLS TO MATCH EXISTING
ADJACENT SURFACES UPON COMPLETION OF WORK.
15. PROVIDE AND RACK DOMESTIC PIPING, VALVES AND APPURTENANCES
COMPLETE ON WALL IN JANITOR'S CLOSET.
16. PROVIDE THERMOSTATIC MIXING VALVE SIZED FOR 14 GPM AND 5 PSI MAXIMUM
PRESSURE DROP. SET TO 110°F.
17. PROVIDE HEAT TRAPS WHERE INDICATED. PIPE IS TO OFFSET DOWN
ACCORDING TO DETAIL 2 ON P-002.
18. REFER TO DETAIL 2 ON P-002 AND RISERS ON P-601 FOR ADDITIONAL PIPE SIZE
INFORMATION IN THE JANITOR'S CLOSET.
N
DETAIL -
3RD FLOOR PLAN
SCALE: 1/2" = 1'-0"
P-105 P-105
P-8
P-105 P-105
C.O.
C.O.
1-1/2"TW
1/2"TWC
3/4"TW
ET-1E
DWH-1E
CP-1E
P-9E
3"FL.D.
TPV
3"W
4"W
2"V
2"V
(E)HW
(E)CW
(E)CW
3/4"TW
1"TW
1"TW
1/2"CW
2"CW
1/2"TWC
1-1/4"TW
1-1/2"TW
1/2"TWC
1-1/2"TW
2"CW
1-1/2"CW
1/2"TWC
1-1/4"TW
7 7
10 11 10 11
10 14
18 16
MEN
RM-301
WOMEN
RW-301
P-1
P-1P-1
P-1
P-2 P-2
P-6
P-6
P-6P-6
P-6 P-4
P-3
P
W
P
P
W
W
3 24 3"W 2"V4
(E)HW&CW
(E)W
(E)W
(E)4"W
(E)CW
LAV 1
LAV 1
LAV 1
LAV1
LAV3
WC WC 11
WC WC 11
WC 1
WC3
UR
UR1
J.S.2
MEN
RM-301 WOMEN
RW-301
P
W
P
P
W
W
(E)HW&CW
(E)W
(E)W
(E)4"W
4CAP
WC
WC
MEN
RM-201
3"FL.D.
3"FL.D.
P-7
3"FL.D.
TPV
3"W1"CW &
3/4"HW
3/4"CW & 1/2"HW
F.C.O.
1-1/2"CW
1/2"HW
F.C.O.
2-1/2"V 7
FI
LE
N
AM
E:
OU
R
RE
F:
PL
OT
D
AT
E:
8/7
/20
6:
:39 A
M
P-
5.D
W G
OF
RE
VI
SI
ON
N
OT
ES
GR
AP
HI
C
SC
AL
E
MARK DATE DESCRIPTION
CE
RT
IFI
CA
TIO
NS
SHEET SIZE:
SHEET
DISCIPLINE SHEET TYPE SEQUENCE
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY DATE DRAFTED:
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
OJ
EC
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
CO
NT
RA
CT
OR
S
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
24 x 36
DC-
2 3 4 5
2 3 4 5
A
B
C
D
DEPARTMENT OF TREASURY
1500 PENNSYLVANIA AV. NW
WASHINGTON DC 20220
BARBARA CHOATE
N/A
MERIDIEN GROUP / CITADEL DCA
SUMMER CONSULTANTS
100%
0018-10
TREASURY ANNEX BUILDING:
RESTROOM UPGRADES
29 MARCH 2019
RESTROOM UPGRADES
MERIDIEN GROUP, LLC
208 SOUTH KING ST. SUITE 303
LEESBURG, VA 20175
(703) 777-8285 www.meridiengroupllc.com
3RD FLOOR PLAN
P-105
N
4'01'2' 2' 1/2"=1'-0"
8'02'4' 4' 1/4"=1'-0"
P-105 P-105
P-105 P-105
File details come from the government source that posted it.